This is an Equipment Technical Specifications document detailing standardized requirements for industrial equipment rental/lease services supporting Norfolk Naval Shipyard (NNSY) and multiple Naval Shipyards. The specifications cover four primary equipment categories: AC Units (three types ranging from 20-ton to 70-ton capacity), Air Compressors (eight types from high-pressure breathing air to diesel oil-free systems), Air Dryers (six types with capacities from 400 CFM to 1250 SCFM and dew points from -40°F to -100°F), and Blasting Equipment (including 8-ton and high-capacity blast pots, abrasive transfer hoppers, and safety totes).

Each equipment type specifies precise technical requirements including capacity ratings, airflow specifications, cooling/heating capabilities, electrical power requirements (predominantly 460V three-phase service with Camlok connections), operating duty cycles (primarily 24/7 continuous), environmental suitability standards (NEMA Type 4, saltwater-resistant, outdoor use), material handling specifications (forklift pockets, certified lift frames, NAVFAC P-307 rigging compliance), and accessory equipment requirements. The document also includes specifications for Chill Water Systems (100-120 ton capacity with modular multi-unit configurations) requiring redundant pump systems, temperature control capabilities (45-55°F range), freeze protection, and insulated piping. All equipment must meet OSHA, ASME, and Navy-specific regulatory standards, include comprehensive markings and identification tags, and comply with shipyard-specific interface requirements such as ducting connections and electrical Camlok compatibility. The specifications emphasize outdoor industrial duty with continuous operation requirements and contractor-provided protective coverings or maintenance as specified for individual equipment types.

View the file

Other files

File Type Posted
IDIQ EQUIPMENT RENTAL MSForms Questionnaire.docx DOCX document
MAC IDIQ Equipment Lease SOW 0106.docx DOCX document
IDIQEQUIPMENT RENATLMSFormsQuestionnaire.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AC Units

RequirementType A: 20-Ton A/C UnitType B: 70-Ton A/C UnitType C: 60-Ton A/C Unit
Design Rating / Capacity20 tons≥780,000 BTU/hr cooling; must provide ≥30°F temperature drop at 12,000 CFM; heater ≥60KW / 200,000 BTU≥60 tons; ≥710,000 BTU/hr cooling
Airflow8,000 CFM≥12,000 CFM at 5” static pressure≥12,000 CFM
Cooling CapacityLowers air temperature to 55°F≥780,000 BTU/hr; must provide ≥30°F temperature drop at 12,000 CFM≥710,000 BTU/hr; Entering air temp (DB/WB) 95/80°F; Leaving air temp (DB/WB) 64/63°F
Heating CapacityReheat capability of 70KWIn-line heater acceptable; ≥60KW capacity; ≥200,000 BTU input; ≥5000 CFM air output; ≥40°F temperature rise; heating and cooling elements thermostatically controlledN/A
PowerElectric, 460V, ≤135AElectric, 120/460V; capable of starting/running on 400A breaker; Camlok requiredMust have compatible electrical connections to building using Camloks
Air Inlets/OutletsTwo (2) 17.5” OD inlets and two (2) 17.5” OD outletsAt least two (2) 20” vent duct inlets and two (2) 20” dampered outletsMust connect to NNSY 20” hard ducts (Wye metal/flex if needed)
DuctingTwo (2) insulated flex ducts, 18” DIA x 25’ LGMust connect to 20” ducting (flex not specified)Must connect to shipyard-supplied duct work; flex duct permitted
Dimensions (Max)106” (L) x 78” (W) x 49” (H)110” (L) x 84” (W) x 70” (H) (typical)Not specified
Weight (Max)3,500 lbs.5,200 lbs. (typical)Not specified
Panel / Electrical ConnectionsNEMA 4 enclosure with lockable disconnect and Camlok cordsLockable connections with Camlok; weather-rated enclosureMust use compatible shipyard Camloks
Environmental SuitabilityContinuous outdoor use; weather and saltwater resistant; meets/exceeds NEMA Type 4Air-cooled; continuous 24/7 operation; exposed to weather/saltwater air; contractor must provide protective coveringsNon-stop operation required; no shutdown unless contractor-performed maintenance
Fan / Coil ConstructionN/AN/AFan type: plenum; Fan control: VIV; Coil: copper tube/aluminum fin
Rigging / LiftingRigging sketch required; NAVFAC P-307 complianceMust comply with NNSY rigging requirementsNot specified
Material HandlingForklift pockets and certified 4-point lift frameFree-standing with forklift slotsNot specified
MarkingsGross weight stenciled on all four sidesMetal tag with vendor info, repair/maintenance POC, phone numberNot specified
ControlsN/AThermostatic controller required for heating and coolingNot specified beyond fan VIV control
System IntegrityN/AMust be a complete, stand-alone systemMust operate as a complete unit, standalone with duct compatibility

Air Compressors

Requirement AreaType A: High Pressure Breathing AirType B: Industrial Oil-Free (Blast Pot & Vacuum Loader)Type B1: Industrial Oil-Free (1050 CFM Standalone)Type C: Diesel Oil-Free Rotary ScrewType D: Tool Air PackageType E: Diesel High CapacityType F: Grade “D” 800 CFM (Base Package)Type F1: Grade “D” 800 CFM + Regenerative Dryer
Purpose / FunctionShip service & breathing air (85 SCFM @ 5000 psi).Industrial blasting & vacuum operations.Industrial oil-free air (standalone).Diesel-powered rotary screw for continuous oil-free supply.Tool/medium-capacity Grade “D” air package with compressor, dryer & receiver.Large diesel compressor (high-capacity industrial air).High-capacity Grade “D” oil-free supply.High-capacity Grade “D” package with integrated regenerative dryer.
Air Supply Parameters≥85 SCFM @ 5000 psig.1050 CFM @ 125 psig.1050 CFM @ 125 psig.≥1500 CFM @ 150–125 psig.≥400 CFM @ 125 psig.1600 CFM @ 150 psig.≥800 CFM @ 125 psig.≥800 CFM @ 125 psig.
Air QualityCertified breathing air (OPNAVINST/OSHA).Not breathing-air rated. Dryer dew point -40° to -100°F.Not breathing-air rated.ISO 8573-1 Class 0 oil-free.Grade “D” per CGA G-7.1; ISO 8573-1 Class 0 acceptable.Industrial air only.Grade “D” per CGA G-7.1 or ISO 8573-1 Class 0.Grade “D” per CGA G-7.1 or ISO 8573-1 Class 0; Dryer dew point -65°F.
CoolingAir-cooled aftercooler.Air cooled.Air cooled.Aftercooler + moisture separator.Moisture separator (electric) aftercooler.Not specified.Moisture separator (electric) aftercooler.Regenerative dryer (heatless twin tower) + aftercooler.
Power SupplyElectric 460V, 3-ph, 60Hz, ≤100A.Compressor: 460V ≤350A; Dryer: 115V, 1-ph; Loader: 460V, 200 HP ≤250A.460V, 3-ph, 60Hz; ≤350A; one 400A circuit.Diesel-powered, ≥8 hr runtime/tank.Compressor: 460V, 3-ph, ≤150A; Dryer: 110/120V, 1-ph; Receiver passive. Kamlock 500 MCM fitting required.Diesel-powered, ≥24 hr runtime.Electric 460V, 3-ph, 60Hz, 400A circuit breaker; color-coded cables.Electric 460V, 3-ph, 60Hz, up to 400A; Dryer: 110/120V, 1-ph.
Duty Cycle24/7 continuous.24/7 continuous.24/7 continuous.24/7 continuous.24/7 continuous.≥16 hrs/day, 7 days/week.24/7 continuous.24/7 continuous.
DesignContainer/skid; louvers for rain protection.Electric oil-free skid-mounted with accessories.Electric oil-free skid/containerized.Diesel rotary screw, fixed speed.Oil-free rotary screw, fixed speed; packaged as a complete system with dryer & receiver.Diesel, free-standing or trailer.Skid/containerized; outdoor duty.Container/skid, integrated dryer package.
Automation / ControlsAuto start/stop at 3000–5000 psi; alarms; minimal monitoring.NEMA panels, Camloks, alarms.Fully automatic switching, alarms, indicators; monitor ≤1x/24 hrs.Auto controls, alarms.Fully automatic controls, alarms, indicators; tech brochure required; delivery date acknowledgement required.Basic diesel controls.Fully automatic controls, alarms, indicators.Fully automatic controls, alarms, indicators; minimal monitoring.
Accessory EquipmentFiltration/purification; dryer; aftercooler; receiver; hygrometer; CO monitor.Dryer (1050 CFM); blast pot; vacuum loader (200 HP).Moisture separator (electric aftercooler), whip checks, calibrated gauges.Moisture separator; whip-checks; gearbox vacuum casing.• Regenerative dryer (≥400 CFM, -100°F dew point, heatless twin-tower) • ASME 200–300 gal receiver (200 psi WP, PRV rated at 200 psi, reducing valve to 120 psi, 2” NPT outlets) • Moisture separator aftercooler • All interconnect hoses provided by contractorMinimal accessories; vendor/POC tag.Whip-checks; calibrated gauges; relief valves sealed/tagged.Larger regenerative dryer (930 CFM, -65°F dew point, heatless twin-tower); moisture separator; whip-checks; calibrated gauges.
Environmental SuitabilityOutdoor duty; NEMA Type 4; saltwater resistant.Outdoor; ≤95 dBA.Outdoor duty; NEMA Type 4; saltwater resistant.Outdoor; NEMA Type 4; saltwater resistant.Outdoor duty; NEMA Type 4; contractor to provide coverings.Outdoor industrial duty.Outdoor duty; NEMA Type 4; saltwater resistant.Outdoor duty; NEMA Type 4; contractor to provide coverings.
Dimensions / Weight≤8’W x 20’L x 10’H.Compressor: 17’8”x7’3”x7’9”, 15,000 lbs; Dryer: 9’x7’x8’, 4700 lbs; Loader: 16’x8’x10’, 12,500 lbs.17’8” x 7’3” x 7’9”, 15,000 lbs max.Not specified.Not specified. Free-standing, forklift capable.Not specified.Container/skid; ≤20’L x 8’W; stenciled gross weight.Container/skid; ≤20’L x 8’W; stenciled gross weight.
Connections½” male 6000# CPV union end; Camlok electrical interface.Compressor: 3” GB38; Dryer: 3” Boss; Loader: Camloks.2” Male NPT (adapters if required).2” male NPT.Compressor: Kamlock 500 MCM; Receiver: 2” NPT outlets. All interconnects provided by contractor.4” male NPT.2” Male NPT inlet/outlet (adapters if required); Camlok electrical per NNSY interface.2” Male NPT inlet/outlet (adapters if required); Camlok electrical per NNSY interface.
Condensate / Spill Control12’ condensate hose; drip pans.Dryer auto drains.Moisture separator auto drains.Not specified.Dryer auto drains.Not specified.Relief valves sealed and tagged; condensate captured.Dryer condensate purges; relief valves tagged.
Rigging / LiftingForklift/crane; attachments w/ 5:1 safety; shackles RR-C-271D; rigging sketch.Forklift pockets; 4-point lift frames; rigging sketches; NAVFAC P-307.Forklift/crane; overhead lift attachments; shackles RR-C-271D; rigging sketch.Forklift/crane; shackles RR-C-271D; rigging sketch.Forklift slots; rigging per NAVFAC/Norfolk. Rigging sketch required.Forklift slots; NNSY Attachment B rigging.Forklift/crane; attachments w/ 5:1 safety; shackles RR-C-271D; rigging sketch.Forklift/crane; attachments w/ 5:1 safety; shackles RR-C-271D; rigging sketch.
MarkingsGross weight + “Lift Here”; plates w/ capacity, pressure, motor HP/RPM, dew point, manufacturer, serial.Gross weight stenciled; manufacturer tags.Gross weight stenciled; manufacturer tags.Gross weight + “Lift Here”; capacity, pressure, dew point, serial.Gross weight; plates with capacity, pressure, temp, dew point, serial. Brochure/tech sheet required.Gross weight stenciled; vendor/POC tag.Gross weight + “Lift Here”; plates with air capacity, supply pressure, temp range, dew point, manufacturer, serial.Gross weight + “Lift Here”; plates with air capacity, supply pressure, temp range, dew point, manufacturer, serial.
Regulatory ComplianceOSHA, ASME BPVC.ASME VIII, UFC 3-430-07, NAVFAC rigging.OSHA, ASME BPVC.OSHA, ASME BPVC.OSHA, ASME BPVC, CGA G-7.1.OSHA, NNSY rigging.OSHA, ASME BPVC, CGA G-7.1.OSHA, ASME BPVC, CGA G-7.1.

Air Dryers

Requirement AreaType A: 850 CFM, –100°FType B: 1250 SCFM, –40°F w/ FiltersType B1: 1050 CFM, –40°F / –100°F w/ FiltersType C: 930 CFM, –70°FType D: 400 CFM, –100°FType E: 930 CFM, –65°F
Purpose / FunctionMedium flow, very dry air.High flow, filtered, moderate dew point.High flow, filtered, dual dew point option.High flow, detailed compliance.Small package dryer.High flow, dew point slightly less strict (–65°F).
Capacity / Flow≥850 CFM @ 125 psig.Inlet 1500 SCFM @ 125 psig → outlet ≥1250 SCFM.1050 CFM @ 125 psig.≥930 CFM @ 125 psig.≥400 CFM @ 125 psig.≥930 CFM @ 125 psig.
Dew Point–100°F.–40°F or lower.–40°F or –100°F (configurable).–70°F.–100°F.–65°F.
Power110/120 VAC, 60 Hz, 1-ph.120 VAC, 1-ph.115 VAC, 1-ph, 60 Hz.110/120 VAC, 60 Hz, 1-ph.110/120 VAC, 10 Hz, 1-ph.110/120 VAC, 60 Hz, 1-ph.
DesignHeatless, twin-tower.Heatless, twin-tower w/ filters.Regenerative, heatless, dual desiccant w/ full filter package.Heatless, twin-tower w/ auto purge, OSHA/ASME.Heatless, twin-tower.Heatless, twin-tower w/ auto purge, OSHA/ASME.
Connections2” NPT inlet/outlet.Two (2) 2” NPTF.3” Boss (inlet/outlet).2” Male NPT (adapters if req.).2” NPT outlet.2” Male NPT (adapters if req.).
Duty CycleContinuous 24/7.Continuous 24/7.Continuous 24/7.Continuous 24/7.Continuous 24/7.Continuous 24/7.
EnvironmentOutdoor shipyard, NEMA 4.Outdoor, NEMA 4.Outdoor, NEMA 4; NAVFAC-P-307 rigging.Outdoor, NEMA 4.Outdoor, NEMA 4 (simpler spec).Outdoor, NEMA 4.
Construction / RiggingFree-standing, forklift slots, rigging req.Heavy duty frame, one-piece skid.Forklift pockets, 4-point lift frame, rigging sketch (NAVFAC-P-307).Container/skid, forklift, crane, rigging diagram.Free-standing, forklift slots.Container/skid, forklift, crane, rigging diagram.
Special FeaturesSimple dryer.Prefilter/afterfilter, alarms, purge saving device, dew point sensors.Prefilter + oil removal + 1-micron afterfilter w/ gauges; dual dew point capability; gross weight stenciled; Camlok cords.Relief valves, calibrated gauges, power cable color coding, OSHA/ASME compliance.Brochure/tech sheet required; delivery date required.Same as Type C but dew point spec relaxed (–65°F).
ComplianceNorfolk rigging.ANSI, NEMA, NEC, ASME BPVC.OSHA, ASME, NEMA; NAVFAC-P-307 rigging; ANSI/NEC.OSHA, ASME, NEMA, NEC, Navy interface.OSHA/ASME (implied).OSHA, ASME, NEMA, NEC, Navy interface.

Blasting Equipment

SpecificationType A: 8 Ton Blast PotType B: High Capacity Blast Pot (Multi-Pot System)
Chamber DesignSingle chamber vessel constructed per ASME Section VIII, Div. 1Four (4) high-capacity blast pots, cone bottom, 175 PSI pressure rating
Certification/StandardsUFC 3-430-07 (24 Jul 2003, Chg 5, May 2019)Conforms to OSHA and NAVFAC P-307 rigging standards
Working Pressure150 psi175 psi
Control SystemStainless steel control boxesSeparate stainless-steel main power supply panel (110 VAC input, 24 VDC control), plus dedicated 24 VDC blaster control panel with safety/indicator features
PipingStainless steel pipingOversized 1.5” high-flow compressed air piping; integrated high-volume abrasive loading piping with quad diffuser
Fittings IncludedStartup fittings (excl. hoses, whip hoses, control lines, deadman controllers)500 MCM Camlock fittings; 7” full-port popup plunger; Schmidt Thompson II abrasive metering valves; independent regulators per pot
Mobility/HandlingForklift pockets; 4-point certified lift frameOversized forklift pockets (5.5”H × 11.5”W); certified top crane lift pad eyes; OSHA compliant removable handrails & access ladders
MarkingsGross weight stenciled on all four sidesApprox. 7,200 lbs empty; gross weight stenciled; dimensions 9’5”L × 8’4”W × 10’6”H
RiggingRigging sketch provided; conforms to NAVFAC P-307Rigging sketch required; lifting & rigging must conform to NAVFAC P-307
Accessories/FeaturesNone beyond startup fittingsHigh-volume abrasive hopper w/ even-fill loading; internal venting system; 4 quick-open access manways w/ ladders; rupture disk overpressure protection; remote choke/blowdown; LED blast lights with comm flicker system; hopper toe rails; sandblaster communication features
ComplianceMeets Requirements for Lifting of EquipmentMeets OSHA, NAVFAC P-307, and “Requirements for Lifting of Equipment”
SpecificationType C: Abrasive Transfer Hopper/System (PUKER)
Weight~950 lbs (empty)
Dimensions55” L × 56” W × 50” H (OAH)
Storage Capacity8.5 cubic feet
Construction/DesignHinged lid; cone-bottom design
Connections500 MCM Crimp Tube Series E1022 male Camlock fittings
Mobility/HandlingOversized forklift pockets, 3.5”H × 9.5”W (full open)
Control SystemStainless steel 24 VDC control panel; connects to blast control panel for power
Indicators/ControlsHigh/low level indicator lights; automatic transfer controls
Abrasive Transfer Pot1.5 cubic foot capacity
Air Piping1” oversized air piping
ValvesFull-port 6” power popup plunger with manual close for maintenance
RegulatorsIndividual regulator rated for 175 PSI
SpecificationType D: Abrasive Safety Totes (GRIT BINS)
Weight~950 lbs (empty)
Dimensions48” L × 48” W × 71” H (OAH)
Storage Capacity55 cubic feet (non-steel abrasives)
Maximum Abrasive Capacity8,000 lbs
Design FeaturesStackable design
Construction/AccessHinged weatherproof access cover (18” × 14”)
Connections1 ¼” vent and fill pipe
Mobility/HandlingCertified top crane lift pad eyes; 4-way forklift pockets (3.35” × 9.5”)
Dispensing6” paddle gate

Chill Water System

Feature / RequirementType A: Single Unit (100–110 Ton)Type B: Multi-Unit (30+30+60 Ton, 120 Ton)Type C: Multi-Unit (30+60 Ton, 90 Ton)Type D: Multi-Unit (30+30+60 Ton, 120 Ton, Enhanced Monitoring)
Capacity100–110 Ton air-cooled chillerThree chillers (2 × 30 Ton + 1 × 60 Ton), modular systemTwo chillers (1 × 30 Ton + 1 × 60 Ton), modular systemThree chillers (2 × 30 Ton + 1 × 60 Ton), modular system
Operation24/7 continuous operation24/7 continuous operation24/7 continuous operation24/7 continuous operation
Pump SystemSingle pump (min.), 200–350 GPM at 150 ft head≥2 pumps, 30–350 GPM, 100 ft head, +100 GPM redundant≥2 pumps, 30–500 GPM, 250 ft head, +100 GPM redundant≥2 pumps, 30–350 GPM, 100 ft head, +100 GPM redundant
Reservoir/Tank≥250 gal, vertical, ≤36” dia., transparent≥250 gal, transparent, bottom-feed / top return≥250 gal, transparent, vented or open to atmosphere≥250 gal, transparent, supports small leaks
Manifolds2 × inlet + 2 × outlet, 2-1/2” MNPT, globe valves5 × inlet + 5 × outlet, 2-1/2” MNPT, globe valves, brass/bronze10 × inlet + 10 × outlet, 2-1/2” MNPT, globe valves + isolation4 × inlet + 4 × outlet, 2-1/2” MNPT, globe valves
Electrical460/480V, 400A breaker max, 500 MCM CamlockSameSameSame
Freeze ProtectionNot specifiedHeating rod/element in expansion tank (Nov–Apr)Must prevent freezing at 0°F, heating element requiredMust prevent freezing at 0°F
Bypass LineYes – globe valves to allow flow when idleYes – sequenced bypass system with globe valvesYes – bypass with globe valves for throttlingYes – bypass with globe valves
Ventilation / Air RemovalNot specifiedConstant ventilation at high pointVent required or open tankNot specified
Piping / InsulationHoses/fittings insulated, routed to avoid kinks/tripping hazardsInsulation required (NBR ASTM C543), Wye fittings preferredHoses/manifolds insulated to reduce losses/condensationHoses/manifolds insulated to reduce temperature loss
Temperature RangeDesired: 45–55°F, Evaporator <45°FDesired: 45–65°F, Evaporator <65°FDesired: 55–65°F, Evaporator <65°FDesired: 55–65°F, Evaporator <65°F
Condenser PerformanceOperates in 0–125°F ambientSameSameSame
InstrumentationInlet/outlet pressure gages, electric monitoring (temps/flows)Inlet/outlet temp gages, outlet pressure gage, flow indicator, manifold gagesInlet/outlet temp gages, outlet pressure gage, manifold gagesInlet/outlet temp gages, outlet pressure gage, electronic monitoring system with alarms (temp, pressure, flow)
Environmental Catch TankRequired if ≥55 gal fluidsSameSameSame
Construction & MobilityFree-standing, forklift slots; gross weight markedFree-standing modular, fork-movableFree-standing modular, fork-movableFree-standing modular, fork-movable
MarkingsGross weight marked per rigging requirementsSameSameSame
TaggingMetal tag with supplier name, POC, phoneSameSameSame
Rigging / LiftingNAVFAC P-307 requirementsSameSameSame
Type A:Type B and D:Type C:
Note 1: Final system may consist of different quantities of Chillers and Pumps (P) than shown in Figure (1) as long as the requirements above are met. Note 2: Final system may change the order of components as long as the requirements above are met. Note 3: Freeze protection is not shown in Figure (1). A Freeze protection method shall be included for the system in the event there is no colling load on the system. Note 4: Figure does not represent the correct amount of supply and discharge manifold connections. See Paragraph 6 for the required amount of connections.

Final system may consist of different quantities of Chillers and Pumps (P) than shown in Figure (1) as long as the requirements above are met. Note 2: Final system may change the order of components as long as the requirements above are met. Note 3: Freeze protection is not shown in Figure (1). A Freeze protection method shall be included for the system in the event there is no colling load on the system.

Chiller

SpecificationType A: 60 Ton Chiller Unit
CapacityMinimum 60 Ton
Cooling TypeAir-cooled
Power Requirements460/480V, (1) 400 Amp breaker, male 500 MCM Camlock fitting
Pump RequirementsSingle 500 GPM circulating pump (minimum); must supply 500 GPM at minimum 80 ft head
Operation24/7 continuous operation
Electrical PanelNEMA 4 metal enclosure with lockable disconnect and Camlock cords
ConnectionsWater inlets/outlets: 6” Camlock each
Hoses(2) × 25 ft, 6” dia. Camlock hoses (suitable for application use)
System CompletenessComplete system; if pump separate, vendor to provide piping/valves/fittings
EnvironmentIndustrial use, resistant to dust, dirt, and sea air; weather tight for outdoor use
Markings/WeightGross weight stenciled on four sides
Mobility/HandlingFree standing, forklift pockets, 4-point certified lift frame, suitable for crane movement
InstrumentationInlet/outlet temperature gages; flow indicating device
PerformanceEvaporator must deliver leaving temp < 40°F; condenser operable 0–125°F ambient
RiggingRigging sketch required; NAVFAC-P-307 compliant
Electrical AdaptabilityMust conform to Appendix A hook-ups; vendor to provide 440VAC–220VAC transformer if required
Maintenance/ServiceVendor responsible for all repairs and maintenance; service response within 4 hours (24/7 including holidays); replacement unit within 24 hours if failure occurs
ComplianceOSHA regulations
ReliabilityFully operational within 24 hours of delivery; must function without repair/adjustment once set up
CablingPower cable end fittings lugged and color coded for proper phasing
Remote MonitoringVendor shall provide electronic remote monitoring/management tool for NNSY personnel
Lifting RequirementsOverhead lifting attachments required: • Each must support ½ gross weight (multi-point) or full weight (single point), design factor 5:1 • Accept standard anchor shackle (RR-C-271D, type IVA) • No side loading • Marked “Lift Here” (letters ≥1”) • Lifting sketch to detail requirements/configurations

Dust Collectors

Requirement AreaType A: 10,000 CFM Cartridge Dust Collector
Purpose / FunctionMedium/large blast operations; cartridge-style dust collection; portable outdoor use.
Airflow Capacity10,000 CFM (minimum).
Filtration SystemCartridge style, electric-powered, fan-driven with in-line filter bank (painting option).
Fan / Motor40 HP minimum fan; motor 460V, 3-phase, 60Hz.
Inlets / DuctsTwo (2) – 16” inlets per collector; includes six (6) 16” dia x 25’ insulated flex ducts with helical reinforcement.
Exhaust / DischargeFan discharge with manual damper for airflow control.
Dust DisposalHoppers discharge into 55-gallon drums; includes adaptor, flex hose, and drum cover.
Power SupplyElectric; 460V, 3-phase, 60Hz; NEMA 4 panel with lockable disconnect and Camlok cords.
Duty CycleContinuous 24/7 outdoor use; all components weather-resistant, NEMA Type 4.
ConstructionForklift pockets; 4-point certified lift frame; NAVFAC P-307 compliant rigging sketch required.
MarkingsGross weight stenciled on all four (4) sides.
AccessoriesIn-line filter bank rated for 10,000 CFM; new filters for painting option.
ComplianceANSI, NEMA, NEC, ASME BPVC, NAVFAC P-307 rigging.
Model ReferenceJTS-DFT4-32-40 or equal.

Generators

Spec CategoryType A: 1000 kW (COP 700 kW)Type B: 1000 kW (COP 500 kW)Type C: 1500 kW (COP 1000 kW)Type D: 1000 kW (COP 750 kW)Type E: 45 kW Standby Diesel Generator
Output450V, 3Ø, 3-wire ungrounded450V, 3Ø, 3-wire450V, 3Ø, 3-wire ungrounded450V, 3Ø, 3-wire ungrounded480/277V, 3Ø, 3-wire ungrounded
Standby Rating1000 kW min1000 kW min1500 kW1000 kW min44/55 kW/kVA
Continuous Power (COP)700 kW500 kW1000 kW750 kW—
Parallel OpsYes, with ship electric plant and shipboard gen (neutral lifted)Standalone onlyYes, with ship electric plant & shipboard gen (droop settings adj.)Yes, with ship electric plant & shipboard gen (neutral lifted)No (standalone ops only)
Dimensions/Weight≤ 20’L × 8’W, ≤ 45,000 lbs≤ 20’L × 8’W, ≤ 50,000 lbs≤ 20’L × 8’W, ≤ 50,000 lbs≤ 20’L × 8’W, ≤ 45,000 lbsSkid ≤ 8’L × 4’W; with trailer ≤ 13.5’L; ≤ 4,500 lbs
Fuel Tank24 hr run; external ≤ 1240 gal or 2× ≤ 6200 lbs each24 hr run; external ≤ 10’×8’, ≤ 10,000 lbs24 hr run; trailer-mounted; ≤ 25,000 lbs; 100’ solid fuel line24 hr run; external ≤ 1240 gal or 2× ≤ 6200 lbs each24 hr run; onboard only (no external fuel tank allowed)
Cooling SystemSelf-containedSelf-containedSelf-containedSelf-containedSelf-contained
Mounting/TransportTrailer mountedTrailer mountedTrailer mounted w/ jack stands & tire chocksTrailer mountedTrailer mounted; single axle, 2,000 lb tongue jack
Safety/OtherLong time O/C trip 150% COPLong time O/C trip 150% COPLong time O/C trip 150% COPLong time O/C trip 150% COPLong time O/C trip; Camlock connections
EnclosureRain-tight, outdoorRain-tight, outdoorRain-tight, outdoorRain-tight, outdoorRain-tight, outdoor
Age/Maintenance≤ 10 yrs, tested ≤ 2 weeks before deliveryClean, well maintained≤ 10 yrs, tested ≤ 2 weeks before delivery≤ 10 yrs, tested ≤ 2 weeks before delivery≤ 5 yrs, government reserves right of refusal
InstructionsPosted at control panel; incl. ship parallel opsPosted at control panelPosted at control panel; incl. ship parallel opsPosted at control panel; incl. ship parallel opsPosted at control panel (basic start/stop/ops)
Trailer SpecsN/A (general trailer reqs)N/ATrailer w/ jack stands, tire chocksN/AHydraulic surge brakes; 2” hitch (reversible ball/pintle preferred); DOT compliant lights; plug adapter

HAZMAT Enclosures

Requirement AreaCommon FeaturesType A: 400 Gal SumpType B: 850 Gal SumpType B1: Enhanced 850 Gal Sump
Guiding DocumentsUFC 1-200-01, 3-301-01, 3-600-01; NFPA 1 & 70; NEC; IBC 2012; ADA; NAVFAC P-307Same as CommonSame as CommonSame as Common
Container DimensionsMinimum 8’ W × 9’ H × 20’ LSame as CommonSame as CommonSame as Common
Sump Capacity—≥400 gallons≥850 gallons≥850 gallons
Climate ControlA/C & heat; Energy Star rated heat pump; maintain set temperature year-round70°F fixed70°F fixed75°F adjustable (Gov’t control)
Fire ProtectionDry chemical suppression system; NFPA/OSHA compliantSame as CommonSame as CommonAdds 4-hour fire-rated walls + detailed fire suppression inspection & maintenance program
Electrical120/240V, 100A load center; camlok → 600V/40A breaker → 15kVA transformer; NEC/NEMA compliantSame as CommonSame as CommonSame as Common
MaintenanceEquipment repair/replacement (excl. negligence); fire suppression troubleshooting; door repair; quarterly A/C filter changesSame as CommonSame as CommonExpanded to include suppression system setup, fusible link checks, Condition Found Reports (CFRs)
HAZMAT Enclosure FeaturesHurricane proof 110 MPH; lockable outward-swinging doors; multiple keys; no windows; decals with unique ID; steel grate flooring; hazard signageSame as CommonSame as CommonAdds 500 psf floor load rating, raised grating, and liquid-tight seams
Fire ExtinguishersOne (1) per door (dry chemical NIIN: 4210-01-467-3616)Same as CommonSame as CommonSame as Common
Ventilation——Non-sparking electric exhaust fans or mechanical ventilation system required
Electrical Wiring StandardsNEC compliant: THHN/THWN; EMT or LFMC conduit; NEC color coding; transformer bonding; NFPA 70Same as CommonSame as CommonSame as Common

Machines

Requirement AreaType A: Laser Ablation System
Core Components• Laser Resonator • Optical Fiber Coupling System • Cooling System • Central Control Unit • High Frequency Unit • Power Supply Module
PerformanceMaximum Laser Power: 1000 Watts
Connectivity• 300 feet of tether • Must use electrical connections compatible with Norfolk Naval Shipyard
Accessories / Consumables• One (1) ALS-LFE301CFM Filter Media, Carbon, for LFE 301 Extractor • Ten (10) ALS-OSH80 Protective Glass, OSH 80

Pumps

SpecificationType A: JP-5 Diesel PumpType B: Sea Water Pump (Standard Pressure)Type C: Sea Water Pump (High Pressure)Type D: Submersible Fire Pump (10,000 GPM)
Power source / ElectricalDiesel engine, max 1500 RPMElectric, 460/480 V, starts/runs on 400 A breakerElectric, 460/480 V, starts/runs on 400 A breakerDiesel engine
Electrical connectionN/AMale 500 MCM Camlock (power)Male 500 MCM Camlock (power)N/A
Hydraulic capacity / head≥150 GPM @ 50 PSIG (max working pressure 50 PSIG)≥400 GPM @ 60–70 PSIG at ~60 ft delivery head, 20 ft suction head≥400 GPM @ 180 PSIG10,000 GPM @ ≥100 ft vertical lift (meets 100 ft horizontal as well)
PrimingAutomatic priming for suction lifts to 28 ft; no foot valve requiredNot specifiedNot specifiedSubmersible (not applicable)
Fuel system / runtimeIntegral diesel tank ≥40 galN/A (electric)N/A (electric)Onboard diesel tank for ≥8 hrs runtime
Connections (process)3" suction, 2" discharge (Camlock)2-1/2" Male NPT discharge; suction hose with strainer2-1/2" Male NST discharge; suction hose with strainerNFPA-approved fire connections; Storz interfaces (see Accessories)
Hoses & accessories (included)(1) 3" × 20' suction hose, JP-5 rated, M/F Camlock; pressure-tested and cleaned for JP-5(5) × 10' suction hoses (350 PSIG max WP / 1400 PSIG burst); strainer(5) × 10' suction hoses (350 PSIG max WP / 1400 PSIG burst); strainerAttached hose, fittings, hose reel; mounted deployment/retrieval crane; (4) Jumbo Boz 5.0" Storz Rigid × 6.0" Female Swivel (short handle, no cap) and (2) Gated-Y Storz Rigid × 2.5" NHM
Controls / gaugesDischarge pressure gauge (0–100 PSIG)——Posted operating instructions on unit
Duty cycleContinuous (emergency JP-5 service)24/7 capable (backup pump kept on standby)24/7 capable24/7 capable
Enclosure / winterizationWinterization: water-jacket & lube-oil sump heaters——Full enclosure with roll-up doors
Mounting / mobilityTrailer-mounted compact unit with integral tankFree-standing; forklift slotsFree-standing; forklift slotsTrailer-mounted; bumper-pull or gooseneck (2-5/16" ball); jack stands & chocks as applicable
Marking / age / testingTotal weight stenciled (≥1" letters); leak-free; cleaned & dried for JP-5Supplier metal tag with company, POC & phoneSupplier metal tag with company, POC & phone≤10 years old; tested within 2 weeks of delivery; operating instructions posted
Compliance / rigging—Conform to site Rigging Requirements (Attachment/NAVFAC P-307 as applicable)Conform to site Rigging Requirements (Attachment/NAVFAC P-307 as applicable)Lifting points with current capacity certifications; complies with rigging requirements

Refrigerator Boxes

Requirement AreaType A: 20’ Refrigerated BoxType B: 40’ Refrigerated Box
Guiding DocumentsUFC 1-200-01, 3-301-01, 3-600-01; NFPA 1; NFPA 70 (NEC); Federal Spec RR-C-271H; NAVSEA OSHECM Chapter 250; IBC 2012; ADA; Requirements for Lifting EquipmentSame as Type A
DimensionsMinimum: 8’ W x 8’ H x 20’ L (excluding refrigeration unit)Minimum: 8’ W x 8’ H x 40’ L (excluding refrigeration unit)
Power / Electrical• Electrically powered, continuous duty (24/7) • Rated ≤200 amps • Exterior camlok → 600V, 40A, 2-pole breaker → 15kva transformer (440/240V → 240/120V, single-phase) • NEMA 3R enclosures, lockable disconnects • THHN/THWN wire, NEC-compliant supports • Neutral = white; Ground = greenSame as Type A
PerformanceMaintain constant temperature: -3°F to 42°FSame as Type A
Construction / Rigging• Hurricane proof to 110 MPH • Water resistant • No windows • Forklift channels (5” x 10”) full-width enclosed OR lifting pad eyes • Overhead lifting attachments must support ½ gross weight, 5:1 safety factor, standard anchor shackle compatible • “Lift Here” marking (1” letters, contrasting color) • Gross weight stenciled • Lifting sketch/rigging diagram requiredSame as Type A
Interior / FixturesBlast-proof fluorescent (or LED substitute) twin-tube fixtures with electronic ballast, centrally mountedSame as Type A
Operational ReadinessUnits delivered cleaned, disinfected, and ready for food or medicine storageSame as Type A
Safety / Identification• Dry chemical fire suppression system (NFPA/OSHA compliant) • Decal: contractor name, contract number, unique ID (8.5”x11”, white with black text, placed on exterior door or electrical panel) • Lockable outward swinging doors, multiple key sets providedSame as Type A
Accessories / Power Interfaces• 120V, 20A Quad receptacles (#12 AWG; min. 2 per circuit) • 120V, 15A duplex GFCI receptacle in exterior weatherproof box (near HVAC unit) • Fusible disconnect (NEMA 3R) w/ current limiting fuses (optional)Same as Type A
MaintenanceContractor to perform: – Equipment repair/replacement (except negligence) – Fire suppression maintenance – Door repair/replacement – Quarterly A/C filter changes • Safety/maintenance plan requiredSame as Type A

Tanks

Requirement AreaType A: 5,000 Gallon Tanker Trailer
Reference / ComplianceNFPA 385, Standard for Tank Vehicles for Flammable and Combustible Liquids
Capacity5,000 gallons
Intended ServiceJP-5 fuel service (cleaned, dry, ready for immediate use)
Pumping CapabilityEquipped with pumping system and 4” Camlock supply fitting (bypass if NNSY provides local pumping)
ConnectionsOne 4” Camlock hose connection to pump complete contents
Duty CycleContinuous operation; emergency JP-5 fuel supply to ship tanks
Delivery / PlacementContractor to deliver and place at NNSY job site (exact location at delivery)
MarkingsTotal weight including fluids stenciled on tanker (letters ≥1” high)
Condition RequirementsFree of leaks, cracks, and holes; fittings secure and intact
Equipment AgeNew or used equipment acceptable
InspectionNNSY Technical POC to inspect upon delivery; Government may reject unsatisfactory units
Additional RequirementsContractor to provide POC info (name and phone number) with equipment

Vacuums

Requirement AreaType A: 200 HP Electric Vacuum LoaderType B: 150 HP Electric Vacuum
Purpose / FunctionHigh-power vacuum loader for abrasive blast media removal (≥16 tons/hour).Medium-to-high power vacuum loader with baghouse & continuous vacuum system.
Model / EqualJTS-IVEC-800EM-200-E or equal.Custom system w/ positive displacement blower & baghouse (no fixed model specified).
Power Requirements460 V, 3 Phase, 60 Hz. Max 250 Amps. Operates from one (1) 400 AMP panel.460/480 V, 3 Phase, 60 Hz.
Horsepower200 HP.150 HP.
Electrical PanelNEMA 4 metal enclosure, soft start, lockable disconnect, Camlok cords.NEMA 4 stainless steel control panel.
Mounting / DesignSkid mounted, continuous operation.Heavy-duty welded skid with forklift pockets; includes maintenance platform, ladder, tie-offs.
PerformanceMax airflow: 4800 CFM. Max vacuum: 27” Hg. Conveying: 400 ft horizontal, 80 ft vertical.Airflow: 2367 CFM. Max vacuum: 28” Hg.
Filtration SystemElectric pulse-cleaned cyclone/baghouse.54” Baghouse with gravity discharge; Double Dump™ continuous vacuum system; 37 snap-lock filter bags; pulse system.
Noise≤95 dBA at 3 meters.Not specified (includes upgraded Class 6 silencer package).
Size (Max.)16’-0” L x 8’-0” W x 10’-0” H.15’-5” L x 8’-1” W x 12’-6” H.
Weight (Max.)12,500 lbs.9,500 lbs. dry.
Rigging & LiftingForklift pockets, 4-point certified lift frame. Rigging sketch required. Must comply with NAVFAC-P-307.Four-point crane lifting cage; hydraulic baghouse lift system.
MarkingsGross weight stenciled on four (4) sides.Painted customer colors; gross weight requirement implied.
Other FeaturesMust convey blast media 400 ft horiz., 80 ft vert.Blower protection micro-filter, emergency shutdown w/ 100’ cord, toolbox, wear plates, inspection hatch.