- Reverse Osmosis System Preventive and Remedial Maintenance Federal contract opportunity
- Solicitation number
- FA813224Q0042
About this file
This document is an equipment list appendix for a Reverse Osmosis (RO) Maintenance Contract. It provides detailed information on the RO systems, associated equipment, and required maintenance activities at various locations.
The key details include the equipment manufacturer, model numbers, serial numbers, and the specific maintenance tasks required for each piece of equipment. This includes replacing filters, media, membranes, and consumable parts; calibrating gauges and meters; and performing standard pump/motor maintenance. The document also lists chemical tanks, pumps, and other ancillary equipment that require maintenance. Additional details are provided for the RO cleaning system, product water holding tanks, and UV filtration systems. This appendix appears to be part of a larger contract opportunity for Reverse Osmosis System Preventive and Remedial Maintenance, as indicated by the related federal contract opportunity information provided.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Apprendix A_Equipment List_FA813224Q0042_Revised 27 Aug 2024 v2.pdf | ||
| Apprendix A_Equipment List_FA813224Q0042_Revised 27 Aug 2024.pdf | ||
| Equipment List_FA813224Q0042_Revised 22 Aug 2024.pdf | ||
| Performance Work Statement_Reverse Osmosis PM RM_revised 22 Aug 2024.pdf | ||
| CSS FA813224Q0042 Reverse Osmosis Water Sysem PM RM_Amendment 1.pdf | ||
| Sol FA813224Q0042 - Reverse Osmosis Water Sys PM RM 7.31.24.pdf | ||
| WAGE DETERMINATION 2015-5313 Rev 24.pdf | ||
| PWS - Reverse Osmosis.pdf | ||
| SAFETY SPECS REFERENCE - APPENDIX C .docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Revised Appendix A1-RO PMXG Maintenance Contract
FA8125-15-M-0045
Tabs Tab: RO Plating Tab: Main Line RO Tab: 095 RO
LOCATION OC-Number NUMBER NAME Manufacturer Model No./Serial No. MAINTENANCE REQUIRED
Building 3001, Post H-53
- Check for proper function on all equipment, i.e. check each system for errors. Verify systems are operating to designed set points. Initiate RM as required.
Building 3001, Post H-53 OC23392 RAW WATER BOOSTER PUMP 1 MARLO INCORPORATED OF RACINE
BOOSTER PUMP SKID MTD / EP-170287-
001-3020 - (Standard pump/motor maintenance)
Building 3001, Post H-53 RAW WATER BOOSTER PUMP 2 - (Standard pump/motor maintenance)
Building 3001, Post H-53 OC23390 MMF-1 MULTIMEDIA FILTRATION SYSTEM MARLO INCORPORATED OF RACINE
MZA-63G DUPLEX/PARALLEL MEDI / EP-
160275-001-1441 - Replace multimedia if required. Expected media life is 10-15 years (expected replacement 2028-2033).
Building 3001, Post H-53 OC23387 CCF-1 CARBON FILTRATION SYSTEM MARLO INCORPORATED OF RACINE ACA-48G DUPLEX PARALLEL CARB / EP- 160275-002-1442
- Replace carbon media if required. Expected carbon life is 2-5 years (expected replacement 2020-2023, based on
ORP).
Building 3001, Post H-53 OC23391 WS-1 WATER SOFTENER SYSTEM MARLO INCORPORATED OF RACINE
MRG-1200-3 DUPLEX ALT WATER S /
EP-160275-003-1443
- Replace 2 consumable bottles for hardness monitor as required (expected replacement every ~2 months). Use:
Hach SP 510 Hardness Monitor Buffer Solution for 20 mg/L Hardness, 500 mL container Hach SP 510 Hardness Monitor Indicator Solution for 5 to 100 mg/L Hardness, 500 mL container
- Hardness monitor 2-point standardization whenever reagent is replaced or when optical system component is replaced.
Use:
Hach TitraVer (EDTA) Hardness Titrant 0.200N, 0.100M, 29 mL container Hach Magnesium Sulfate Solution 10,000 ±1000 mg/L, 29 mL container
- Replace water softener resin if required. Expected resin life is very long, 15+ years (expected replacement 2033 or later).
- Replace hardness monitor pump tubes every 3 months
Building 3001, Post H-53 BRINE TANK
- Clean out brine tank to maintain cleanliness. Minimum yearly.
- Check function on automatic water fill equipment for proper function.
- Provide salt (A-A-694, Type II, Form 1, 40 lb bag) in brine tank to support water softener regenerations.
Building 3001, Post H-53 OC23385 RO-1 REVERSE OSMOSIS SYSTEM 1 MARLO INCORPORATED OF RACINE
MRO-72K-8H SINGLE PASS RO SKID /
EP-160275-004-1113
- Fill antiscallant tank (use PWT SpectraGuard 111, 0.5 gallon container currently authorized
- Replace 5 micron cartridge filter as required when differential pressure reaches 15 psi.
- Calibrate all gauges and meters based on manufacturer's recommendations. Frequency no less than every 3 months.
- Replace membranes when required
- Grease motor bearings quarterly
- Change metering pump cartridge valves yearly
- (Standard pump/motor maintenance)
Building 3001, Post H-53 OC23389 RO-2 REVERSE OSMOSIS SYSTEM 2 MARLO INCORPORATED OF RACINE
MRO-72K-8H SINGLE PASS RO SKID / EP-
160275-013-1120
- Fill antiscallant tank (use PWT SpectraGuard 111, 0.5 gallon container currently authorized
- Replace 5 micron cartridge filter as required when differential pressure reaches 15 psi.
- Calibrate all gauges and meters based on manufacturer's recommendations. Frequency no less than every 3 months.
- Replace membranes when required
- Grease motor bearings quarterly
- Change metering pump cartridge valves yearly
- (Standard pump/motor maintenance)
Building 3001, Post H-53 RO WATER STORAGE TANK - Inspect level sensor and high-high level sensor
Building 3001, Post H-53 OC23386 P-101 RO SUPPLY PUMP 1 MARLO INCORPORATED OF RACINE
RECIRCULATION PUMP SKID WITH / EP-
160275-006-1502 - (Standard pump/motor maintenance)
Building 3001, Post H-53 P-102 RO SUPPLY PUMP 2 - (Standard pump/motor maintenance)
Building 3001, Post H-53 UV FILTER
- Replace UV lamp when required (minimum annually)
- Inspect and clean or replace UV sleeve as required
- Inspect flow meter sensor periodically
Building 3001, Post H-53 OC23388 CIP-1 CLEAN IN PLACE SYSTEM MARLO INCORPORATED OF RACINE MEMBRANE CLEAN-IN-PLACE (CIP) / EP- 160275-005-1491
- Run clean in place cycle as required to maintain RO membranes. Use PWT Lavasol 1, 5 gallon containers currently authorized
- Replace filter as required
- (Standard pump/motor maintenance)
Building 3001, Post H-53 Sodium Bisulfite Chem Tanks (2) Fill with Chemical as required. Ensure sensors function properly. Clean out the tank once a year.
Building 3001, Post H-53 Pumps Associated with SBS (2) Pulsatron LB64SA-VTC1-XX2 Standard Pump/Motor Maintenance Building 3001, Post H-53 Antiscalant Chem Tanks (2) Fill with Chemical as required. Ensure sensors function properly. Clean out the tank once a year.
Building 3001, Post H-53 Pumps Associated with Anticalant (2) Pulsatron LB64SA-VTC1-XX2 Standard Pump/Motor Maintenance
ALL EQUIPMENT
LOCATION NUMBER NAME Manufacturer Model No./Serial No. MAINTENANCE REQUIRED H101 Side A Filter Shelco Microguardian 12F0S4/112739 Ensure filter is not clogged, replace cartridges as needed.
H101 Side A Pump Grundfos A91129158-P21008003 Standard Pump/Motor Maintenance H101 Side B Filter Shelco Microguardian 12F0S4/112739 Ensure filter is not clogged, replace cartridges as needed.
H101 Side B Pump Grundfos A91129158-P21008003 Standard Pump/Motor Maintenance
H101 Sodium Bisulfite Chem Tanks (2) Fill with Chemical as required. Ensure sensors function properly. Clean out the tank once a year.
H101 Pumps Associated with SBS (2) Pulsatron LB64SA-VTC1-XX2 Standard Pump/Motor Maintenance
H101 Antiscalant Chem Tanks (2) Fill with Chemical as required. Ensure sensors function properly. Clean out the tank once a year.
H101 Pumps Associated with Anticalant (2) Pulsatron LB64SA-VTC1-XX2 Standard Pump/Motor Maintenance
H101 Cleaner Tank After use of cleaning out the skid, ensure tank is fully drained. Ensure sensor operates, replace as needed.
H101 Cleaner Tank Filter Shelco Microguardian 7F0S4/112739 Ensure filter is not clogged, replace cartridges as needed.
H101 Cleaner Tank Pump Leeson Electric Corporation C184T34FK15D/131583.00 Standard Pump/Motor Maintenance H101 P-3 Re-Pressure Skid Pump 1 Leeson Electric Corporation C215T34FK10AA Standard Pump/Motor Maintenance H101 P-4 Re-Pressure Skid Pump 2 Leeson Electric Corporation C215T34FK10AA Standard Pump/Motor Maintenance H101 P-5 Distribution Skid Pump 1 Leeson Electric Corporation C215T34FK10AA Standard Pump/Motor Maintenance H101 P-6 Distribution Skid Pump 2 Leeson Electric Corporation C215T34FK10AA Standard Pump/Motor Maintenance H101 Product Water Holding Tanks Ensure level sensor is working properly. Replace as needed.
H101 UltraViolet Lamp Aquafine
Replace UV lamps as needed, minimum of once a year. Clean quartz sleeves as needed, and replace once a year. Clean sensor probe window and replace probe once a year. Replace ballast as needed, though it should be infrequent.
H101 OC20140 Main Line Reverse Osmosis System Hausers Water Systems Ensure membranes are clear of fouling and there are no leaks on the system as a whole. Clean membranes as needed, minimum once a year. Calibrate, clean, or replace any electrodes/sensors as needed.
H101 AC Units for Control Panels (3) Industrial Cooling Equipment HC12012604XCX Clean out filters as needed, minimum of once a year.
LOCATION NUMBER NAME Manufacturer Model No./Serial No. MAINTENANCE REQUIRED
S91 TK-501 RO Cleaning Tank Snyder Industries, Inc.
After use of cleaning out the skid, ensure tank is fully drained. Ensure sensor operates, replace as needed.
S91 TK-502 Antiscalant Chem Tank Fill with Chemical as required. Clean out the tank once a year.
S91 Antiscalant Tank Agitator Liquid Metronics 10590A Standard Maintenance S91 P-501 Antiscalant Metering Pump LMI, Milton Roy P161-468SI/08092663366-2 Standard Pump/Motor Maintenance S91 P-502 Antiscalant Metering Pump LMI, Milton Roy P161-468SI/08092663366-1 Standard Pump/Motor Maintenance S91 Sodium Metabisulfide Tank Fill with Chemical as required. Clean out the tank once a year.
S91 Sodium Metabisulfide Agitator LMI, Milton Roy 6JHX3/71638553 Standard Maintenance S91 Sodium Metabisulfide Metering Pump Pulsatron, Pulsafeeder LB03SA-VTC1-XX2/477907 Standard Pump/Motor Maintenance S91 Sodium Metabisulfide Metering Pump Pulsatron, Pulsafeeder LB03SA-VTC1-XX2/477905 Standard Pump/Motor Maintenance S91 P-201 RO A Feed Pump Grundfos A96523644-P10838574 Standard Pump/Motor Maintenance S91 P-401 RO B Feed Pump Grundfos A96523644-P10838574 Standard Pump/Motor Maintenance S91 P-601 Product Water Feed Pump Grundfos A96523641-P10838602 Standard Pump/Motor Maintenance
S91 TK-602 Bladder Tank Well-X-Trol, Amtrol WX-302 Ensure proper operation of level sensor and clean as needed. Clean tank once a year.
S91 UV-601 UltraViolet Lamp Atlantic Ultraviolet Corp. S2400C Replace UV lamps as needed, minimum of once a year.
S91 CF-601 Post-Treatment Cartridge Filter Ensure filter is not clogged, replace cartridges as needed.
S91 Pre-Treatment Cartridge Filters (2) Shelco Microguardian BFS-2SB-2/130857 Ensure filter is not clogged, replace cartridges as needed.
S91 TK-601 Product Water Holding Tank Clean tank once a year.
S91 OC19792 Automated Cleaning Line RO System LT Technologies Ensure membranes are clear of fouling and there are no leaks on the system as a whole. Clean as needed, minimum once a year. Calibrate, clean, or replace any electrodes/sensors as needed.