Epoxy Floor Coating Location Pictures.pdf
PDF 10 MB Posted
- Attached to
- Epoxy Floor Coating
- Solicitation number
- FA481925R0013
About this file
These images document the interior and exterior of Building 9727 at Tyndall Air Force Base, which is the Robotics Maintenance Facility where an epoxy floor coating project is planned. The photographs show multiple views of a large, open industrial space with concrete floors, exposed ceiling infrastructure, white walls, and multiple windows. The images capture different rooms including storage areas, a utility room with folding chairs and cleaning equipment, and bathroom/restroom spaces. The architectural floor plan (page 7) provides detailed measurements and room layout, indicating the building is approximately 100 feet long and 38 feet wide, with designated spaces for an open office, IT closet, mechanical/utility room, janitor's closet, and restrooms. The concrete floors appear to be in preparation for the specified epoxy coating application, which will need to withstand heavy equipment like forklifts and meet specific aesthetic standards for the Air Force facility.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Epoxy Floor Coating Questions and Answers.docx | DOCX document | |
| Solicitation Amendment FA481925R00130002 SF 30.pdf | ||
| SCA 15-4559.pdf | ||
| STATEMENT OF WORK 9727 Floor 4-21.docx | DOCX document | |
| DBA - FL20250005.pdf | ||
| Solicitation Amendment - FA481925R00130001.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FD
FD
A-201
A-301
A-201
A-2013
A-201 4
OPEN OFFICE
IT CLOSET
MECH/UTIL
104 JANITOR
RR
-D
T E
X T
U R
E F
E A
T U
R E
W A
L L
DROP-DOWN PROJECTOR
SCREEN, PROVIDE POWER ABOVE
NEW GRADE BEAM
PER STRUCT
EDGE OF EXISTING SLAB
NEW GRADE BEAM PER STRUCT
EDGE OF EXISTING SLAB
A-301WH
97' - 10"
100' - 0"
20' - 7"
11' - 2" 9' - 5"
(3
.1
(6'-0" 8'-0")
101.2 101.3
(12'-0" 9'-0")
(3
.4
.5
(1
(6'-0" 8'-0") 101.6
.1
(3
.1
(3
104.1 (3'-0" 8'-0")
103.1 (2'-6" 8'-0")
16' - 5" 5' - 0" 14' - 7 3/4" 26' - 1" 14' - 10 1/4" 12' - 0" 8' - 10"
55' - 8" 6' - 5" 35' - 9"
A-150
W2
W1
A-352
FAAP
A-352
W1 W1
W5
W4 W4
W3
F.E.B.
YARD HYDRANT PER MEP
YARD HYDRANT PER MEP
EXISTING SLAB TO
REMAIN
68' - 0"
ELECTRICAL
106.1 (3'-0" 8'-0")
/2
/2
1' - 6" 32' - 8 1/2" 34' - 0" 1' - 6"
DS.1 DS.1 DS.1 DS.1
DS.1 DS.1 DS.1 DS.1
C O
M M
P A
N E
L B
Y O
T H
E R
S L
F A
C P
2' - 1 1/2"
/2
EDGE OF EXISTING SLAB
EDGE OF EXISTING SLAB
E D
G E
O F
E X
IS
T
IN
G
S L A
B
FLOOR DRAIN
WC DRAIN
MOP SINK DRAIN
DRINKING FOUNTAIN DRAIN
UTILITY SINK DRAIN
FACP
AREA TO CUT EXISTING SLAB FOR NEW UTILITY LINES
EDGE OF NEW GRADE BEAM
E D
G E
O F
N E
W G
R A
D E
B E
A M E D
G E
O F
N E
W G
R A
D E
B E
A M
EDGE OF NEW GRADE BEAM
2' - 1 1/2"
ELEC PANEL
COMMUNICATIONS STUB
WATER SERVICE
EXISTING SLAB
100' - 0"
2' - 1 1/2" 95' - 9" 2' - 1 1/2"
ELEC POWER STUB
L
F A
C P
Project #
Date
© LOGAN ARCHITECTURE, PLLC
Logan Architecture, PLLC 108 Chicon
Austin Texas 78702 512.337.9684 info@loganarch.com
AT
T S
XETE FO
S A
A N D
RE
W LOG
A N
24088
R E G
IS
TE
RED ARCH
ITE
C T
FULL SCALE IS 24X36 SHEET | HALF SCALE IS 12X18 SHEET
T Y
N D
A L L A
F B
P R
O J E
C T
F
A P
A
/2
/2
:3 :1
P
M
A-101
LEVEL 1 PLAN
22.24
USAF
08.30.2022
T Y
N D
A L
L A
IR
F
O R
C E
B A
S E
B
U
IL
D
IN
G
T Y
N D
A L
L R
O B
O T
IC
S
M A
IN
T
E N
A N
C E
F A
C
IL
IT
Y
08.30.2022
100% CONSTRUCTION
DOCUMENTS
3/16" = 1'-0"
FLOOR PLAN
3/16" = 1'-0"
ARCHITECTURAL SLAB PLAN NOTES: REF STRUCT FOR SLAB POURBACK DETAILS. REF MEP FOR
PLUMBING, ELECTRICAL, & DATA REQUIREMENTS.
GENERAL PLAN NOTES:
1. PROVIDE F.R.T. BLOCKING AT ALL
LOCATIONS WHERE WALL MOUNTED
APPURTENANCES ARE TO BE PROVIDED
OR WHERE INDICATED ON THE PLAN WITH
KEYNOTE.
2. SLOPE POUR BACKS WHERE FLOOR
DRAINS ARE PLACED. SET DRAINS 1/2"
BELOW FINISH FLOOR FOR POSITIVE
SLOPE.
3. BOTTOM FINISHED SURFACE OF ALL
CEILINGS AS NOTED IN DRAWINGS. REF.
REFLECTED CEILING PLAN FOR CEILING
DETAILS AND FINISHES.
4. REFERENCE PARTITION SCHEDULE A601
FOR DETAILS REGARDING WALL
COMPOSITION, BASE DETAILS, AND
REQUIRED FIRE RATINGS.
5. DRAWINGS FOR ARCHITECTURAL
DIMENSIONS ONLY- REFER TO PLUMBING
AND MECHANICAL ENGINEER'S DRAWINGS
FOR REQUIREMENTS OF ALL PLUMBING
ELEMENTS.
6. REFER TO MEP DRAWINGS FOR
COMPLETE SUB-SLAB PLUMBING, AND
MECHANICAL SCOPE - ANY CONFLICTS
BETWEEN MEP AND ARCHITECTURAL
DRAWINGS TO BE BROUGHT TO THE
ATTENTION OF THE CONTRACTOR PRIOR
TO PERFORMING THE WORK.
7. TOILET LOCATIONS ARE BASED ON ADA
AND MUST BE PLACED AS SHOWN.
CONFIRM LOCATION OF CLOSET FLANGE
PER TOILET SPEC - DIMENSIONS
PROVIDED
ASSUME VENT CENTERED IN 8" 3-D
PRINTED WALL.
8. LAVATORY LOCATIONS ARE BASED ON
ADA AND MUST BE PLACED AS SHOWN.
9. REFER TO SHEET A-001 FOR ALL
ADA/TAS ACCESSIBILTY RELATED
CONSTRAINTS. NOTIFY ARCHITECT OF
ANY CONFLICTS BETWEEN A-001 AND
ARCHITECTURAL DRAWINGS.
10. BUILDING TO BE FULLY COMPLIANT
WITH UFC 3-301-01 & DD FORM 1391/RD
CONST. ZONE 35% RTA RFP
No. Description Date
| 1 |
| 2 |
| 9727 BR |
| 9727 Janitor closet |
| 9727 Mech room |
| 9727 Storage |
| TYNDALL ROBOTICS FACILITY_100% CD_ADDENDUM 1 4 |
File details come from the government source that posted it. Updated .