eone-grinder-pump-system-dh071-drawings.pdf

PDF 2 MB Posted

Attached to
Install a grinder pump lift station, sewer service line, electrical cabling and pump and abandon existing septic tank.
Solicitation number
246-24-Q-0022
Issued by

About this file

This document contains technical specifications for a grinder pump system and details of a related federal contract opportunity. The grinder pump system described includes a 1 HP motor, 4-inch inlet and 1.25-inch discharge connections, and capacities of 700 GPD and 70 gallons. Accessories like check valves and alarm panels are available. The related federal contract opportunity is to install a grinder pump lift station, sewer service line, electrical cabling and pump and abandon an existing septic tank for the Department of Health and Human Services Indian Health Service. The supplier identified is Haynes Equipment.

View the file

Other files

File Type Posted
SOW_Lift Station and SSL_KMY EDITS.pdf PDF
ok30 (1).txt TXT text file
SF18-95a and Clauses.pdf PDF
Copy of SSL Bid Sheet.xlsx XLSX spreadsheet
eone-dh071-grinder-pump-installation-instructions.pdf PDF
Drawing r1je.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

General Features The model DH071 or DR071 grinder pump station is a complete unit that includes: the grinder pump, check valve, HDPE (high density polyethylene) tank, controls, and alarm panel. A single DH071 or DR071 is a popular choice for one, average single-family home and can also be used for up to two average single-family homes where codes allow and with consent of the factory.

•Ratedforflowsof700gpd(2650lpd)
•70gallons(265liters)ofcapacity

• Indoor or outdoor installation

• Standard outdoor heights range from 61 inches to 160 inches

The DH071 is the “hardwired,” or “wired,” model where a cable connects the motor controls to the level controls through watertight penetrations.

The DR071 is the “radio frequency identification” (RFID), or “wireless,” model that uses wireless technology to communicate between the level controls and the motor controls.

Operational Information Motor 1 hp, 1,725 rpm, high torque, capacitor start, thermally protected, 120/240V, 60 Hz, 1 phase

Inlet Connections 4-inch inlet grommet standard for DWV pipe. Other inlet configurations available from the factory.

Discharge Connections

Pumpdischargeterminatesin1.25-inchNPTfemalethread.Caneasilybe
adaptedto1.25-inchPVCpipeoranyothermaterialrequiredbylocalcodes.

Discharge

15gpmat0psig(0.95lpsat0m)
11gpmat40psig(0.69lpsat28m)
7.8gpmat80psig(0.49lpsat56m)

Accessories E/One requires that the Uni-Lateral, E/One’s own stainless steel check valve, be installed between the grinder pump station and the street main for added protection against backflow.

Alarm panels are available with a variety of options, from basic monitoring to advanced notice of service requirements.

The Remote Sentry is ideal for installations where the alarm panel may be hidden from view. NA0050P01 Rev D

DH071/DR071

XWagoner County RWD #4 Supplier:

Haynes Equipment Scott Powell (405) 755-1357