Environmental_Report.pdf

PDF 2 MB Posted

Attached to
North Tamarind Elementary School - Water Piping Replacement at Kindergarten
Solicitation number
25/26-0039
Issued by
San Bernardino County, California

About this file

This is an Environmental Report prepared by L.Y. Environmental, Inc. for the Fontana Unified School District regarding a Limited Asbestos and Lead Based Paint Survey conducted at Tamarind Elementary School located at 7961 Tamarind Ave, Fontana, California on February 23, 2026. The survey was conducted by Yonan Benjamin, a Certified Asbestos Consultant and Certified Industrial Hygienist, and analyzed by Inland Asbestos Lab, an NVLAP-accredited laboratory. The survey included bulk sampling of wall materials, ceiling tiles, stucco, and insulation components, as well as XRF readings of painted and ceramic tile surfaces to assess lead-based paint presence. The report was completed and delivered on February 24, 2026.

The findings indicate positive asbestos concentrations in the exterior stucco material covering approximately 4,000 square feet, identified as chrysotile asbestos at 2% concentration. No asbestos was detected in drywall, ceiling tiles, or insulation samples collected from interior spaces. Lead-based paint testing results showed all XRF readings below the HUD and California Department of Public Health standard guideline of 1.0 mg/cm², indicating no lead-based paint concerns. The report notes the structure appears intact and in good condition. The survey was conducted in accordance with CAL/OSHA, EPA AHERA, and South Coast Air Quality Management District protocols using non-destructive sampling techniques. L.Y. Environmental notes that dimensional approximations provided are not to be relied upon for bidding purposes and accepts no liability for potential chemical or biological agents not targeted for analysis or present in quantities below detection limits.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

L.Y. Environmental, Inc.

1050 Nevada Street, Suite# 401, Redlands, CA 92374 • Phone (909) 307-9730 • Fax (909) 307-9740

February 24, 2026

Fontana Unified School District Attn: Luis E. Estrada Phone: (909) 357-7520 Email: Luis.Estrada@fusd.net

Summary Report: Limited Asbestos & Lead Based Paint Survey

7961 Tamarind Ave, Fontana, CA 92336 Tamarind Elementary School

I. Introduction

L.Y. Environmental Inc., (LYEI) received a request to conduct a Limited Asbestos and Lead Based Paint Survey for the Tamarind Elementary School located on 7961 Tamarind Ave, Fontana, California. LYEI was requested to inspect the above-mentioned property for the existence of asbestos and lead containing materials and to provide a written report of findings.

II. Background

Yonan Benjamin (CAC DOSH #02/3228) of LYEI conducted the survey at the subject site on February 23, 2026. The report was reviewed and completed by Yonan Benjamin, a Certified Asbestos Consultant and Certified Industrial Hygienist with LYEI.

The structure appears to be intact and in good condition. The samples of the Wall, Ceiling Tile, Stucco, and Insulation Materials were collected. Samples were taken, all of which were analyzed by Inland Asbestos Lab located in Redlands, California, which is an NVLAP Lab (NVLAP Code 201000-0; Ph: 909-435-5504). Asbestos Bulk samples were analyzed by PLM using EPA Method 600/R-93/116, (July 1993), in accordance with 40 CFR 763, Sub-part F, Appendix A (AHERA), and if applicable, the Point Count Method 600/R-93/116 (1000 Point), (July 1993). The survey was conducted in accordance with CAL/OSHA, EPA AHERA and South Coast Air Quality Management District sampling protocols using non-destructive representative sampling techniques. See attached, Asbestos Bulk Sampling Field Log for materials and locations of samples collected.

In addition, XRF Niton XL #9739, Model XLp 300A, 40 mCi Cd-109, readings of all impacted and painted components were taken onsite by Yonan Benjamin, Lead Inspector/Assessor, Cert.# LRC- 00008161.

III. Findings/Conclusions

Asbestos

Results of the bulk sample analysis are attached to this report and showed positive concentrations of asbestos in the stucco material of the Exterior (approx. 4,000ft2). However, there were no concentrations of asbestos in the other structural materials collected and tested. See attached, Asbestos Sampling Field Log for the results and locations.

Lead Based Paint

The results of the onsite XRF readings of the painted and ceramic tile components showed readings below the HUD & CDPH standard/guideline of 1.0 mg/cm2.

Thank you for giving L.Y. Environmental, Inc. the opportunity to participate in this investigation.

We would be happy to provide any additional services, if necessary. Should there be any questions, or if I may be of further assistance, please feel free to contact me.

Sincerely, L.Y. Environmental, Inc.

Yonan Benjamin, CIH CAC LPM Director, Indoor Air Quality and Industrial Hygiene Certified Industrial Hygienist (ABIH #7299) Certified Asbestos Consultant (DOSH #02/3228) Lead Inspector/Assessor (LRC-00008161)

Attachments:

Laboratory Results for Asbestos Chain of Custody

CONDITIONS AND LIMITATIONS

L.Y. Environmental, Inc. (“LYEI”) has prepared this report for the exclusive use of its client. LYEI, in its survey’s measurements, applies approximations of the dimensional areas (square footage) it is not to be relied upon for bidding purposes.

LYEI, in performing its professional services, has applied engineering and scientific judgment that it believes is consistent with OSHA and AHERA industry standards. LYEI has inspected structures and/or contents in a good faith effort to observe pertinent detail. Due to the limitations of time, access, and other variables, certain details may have been overlooked. LYEI has relied in good faith upon the information and representations of others in the preparation of this report and the opinions expressed herein. Accordingly, LYEI accepts no responsibility for deficiencies, omissions, misrepresentations, or fraudulent acts of persons interviewed.

It is always possible that chemical and/or biological agents may be present in a building that have not been targeted for assay, have not been identified by science as a potential health threat, or are present in such small quantities or low levels that they were not detected by the sampling and/or analytical methods employed. It is also possible that variables in sample collection, such as those associated with an isolated or intermittent contaminant, the random selection of a sample location, etc., will affect analytical results. Accordingly, it cannot be determined with absolute certainty that there is no risk of exposure to some chemical and/or biological agents.

LYEI will accept no liability for any loss, injury, claim or damage arising directly or indirectly from any use or reliance on this report or the opinions expressed herein. LYEI makes no warranty, expressed or implied.

Inland Asbestos Lab, Inc.

1040 Nevada St., Suite 300, Redlands, CA 92374

(909) 219-4285 info@inlandalab.com

L.Y. Environmental, Inc. Lab Ref. No.:

Yonan Benjamin 20 Date Collected:

(909) 307-9730 Yonan Benjamin Date Received:

yonan@lyenvironmental.com Acceptable Date Analyzed:

Date Amended:

10 90 260365-12 Drop Ceiling Tile

CT-7 Ceiling Tile - off-white No

95 5 260365-11 K-2 (1'x1')

K-2 (1'x1') CT-6 Ceiling Tile - white, brown

No

95 5 260365-09 K-1 (1'x1') CT-5 Ceiling Tile - white, brown

No 95 5 260365-10

CT-4 Ceiling Tile - white, brown No

260365-07 K-2 (1'x1') CT-3 Tile On Wall - white, brown

No 95 5 260365-08 K-2 (1'x1')

260365-06 K-1 (1'x1')

Tile On Wall - white, brown No

CT-2 Tile On Wall - white, brown No

260365-03 K-2

CT-1

WS-4

260365-04

5 5 90

905 5

Q C

Client Sample ID Inland Sample ID

Sampler: February 24, 2026

Chrysotile

Actinolite

Cellulose

Sample Description - Color Comment

Sample Condition:

Non-Asbestos Constituents, %Asbestos Type, %

Fiberglass

Crocidolite

February 24, 2026

Test Report: PLM Bulk Asbestos Analysis Analytical Method: EPA 600/R-93/116: Method for the Determination of Asbestos in Bulk Building Materials, in conjunction with EPA -- 40

CFR Appendix E to Subpart E of Part 763, Interim Method of the Determination of Asbestos in Bulk Insulation Samples

Project Address: Tamarind E.S., 7961 Tamarind Ave., Fontana, CA 92336

Anthophyllite

Am osite

Asbestos Detected

26020365

February 24, 2026

Number of Samples:

N on-Asbestos N on-Fibrous

Synthetic Fibers

February 23, 2026

Project Name/Number: Fontana USD

Trem olite

K-1

Drywall - white, brownWS-1 No 5 5

260365-01 Drywall - white, brown

260365-02 Storage Room 'N'

Drywall - white, brown No

5No

Storage Room 'S'

WS-2

WS-3 Drywall - white, brown No

260365-05 Storage Room 'S'

WS-5 Drywall - white, brown No 5 5 mailto:info@inlandalab.com

L.Y. Environmental, Inc. Lab Ref. No.:

Yonan Benjamin 20 Date Collected:

(909) 307-9730 Yonan Benjamin Date Received:

yonan@lyenvironmental.com Acceptable Date Analyzed:

Date Amended:

260365-15 Exterior

Stucco - off-white Yes 2

S-1

10 90 260365-14 Drop Ceiling Tile

CT-9 Ceiling Tile - off-white No

10 90 260365-13 Drop Ceiling Tile

CT-8 Ceiling Tile - off-white No

260365-16 Exterior

S-2

26020365

Number of Samples: February 23, 2026

Sampler: February 24, 2026

Sample Condition: February 24, 2026

February 24, 2026

Project Name/Number: Fontana USD Asbestos Type, % Non-Asbestos Constituents, %

Q C

Project Address: Tamarind E.S., 7961 Tamarind Ave., Fontana, CA 92336 Asbestos Detected

Chrysotile

Am osite

Crocidolite

Anthophyllite

Trem olite

Actinolite

Cellulose

Fiberglass

Synthetic Fibers

N on-Asbestos N on-Fibrous

Client Sample ID Inland Sample ID

Sample Description - Color Comment

Stucco - off-white

S-3 Stucco - off-white Yes 2 98

260365-17 Exterior

Yes 2

260365-19

I-1 Insulation - pink No 100

260365-18 On Drop Ceiling I-2 Insulation - pink

No 100

260365-20 On Drop Ceiling

On Drop Ceiling I-3 Insulation - pink

No 100

Analyst(s):

Egypt Bailey

N/A=not analyzed. The above analyses of the samples were performed in general compliance with the procedures outlined in EPA 600/R-93/116: Method for the Determination of Asbestos in Bulk Building Materials, in conjunction with EPA -- 40 CFR Appendix E to Subpart E of Part 763, Interim Method of the Determination of Asbestos in Bulk Insulation Samples. Non-friable organically bound materials may present a problem matrix, therefore Inland Asbestos Lab, Inc. recommends gravimetric analysis. The client is responsible for interpretation and use of test results. This report relates only to the samples reported above and reflects the samples as received. Sample descriptions are generated from the client's field sampling data on the Chain of Custody. This report may not be reproduced, except in full, without written approval from Inland Asbestos Lab, Inc. and must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Inland Asbestos Lab, Inc. bears no responsibility for client sample collection activities or analytical method limitations. The limit of detection for this analytical method is less than 1% and total sample constituents may total greater than 100% due to trace amounts. Building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample unless requested otherwise by the client. Inland Asbestos Lab, Inc. is accredited under the NIST/NVLAP (NVLAP Lab Code: 201000-0) program for bulk asbestos analysis using polarized light microscopy. Samples are within quality control criteria and met method specifications unless otherwise noted.

Estimation of uncertainty is available upon request. Please feel free to contact Inland Asbestos Lab, Inc. regarding any questions about this report.

Approved by: Julia Benjamin, Laboratory Director Approved Signatory

February 24, 2026

Date Sampling: 2/23/2026 Page 1 of 1 Children: Yes Year Built: 1980's

SAMPLE # ROOM WALL COMPONENT SUBSTRATE

PAINT

CONDITION

READING RESULT

1 K-1 A Wall Plaster/Gypsum Intact 0.00 Negative

2 K-1 B Wall Plaster/Gypsum Intact 0.00 Negative

3 K-1 C Wall Plaster/Gypsum Intact 0.00 Negative

4 K-1 D Wall Plaster/Gypsum Intact 0.00 Negative

5 Middle A Wall Plaster/Gypsum Intact 0.00 Negative

6 Middle B Wall Plaster/Gypsum Intact 0.00 Negative

7 Middle C Wall Plaster/Gypsum Intact 0.00 Negative

8 Middle D Wall Plaster/Gypsum Intact 0.00 Negative

9 K-2 A Wall Plaster/Gypsum Intact 0.00 Negative

10 K-2 B Wall Plaster/Gypsum Intact 0.00 Negative

11 K-2 C Wall Plaster/Gypsum Intact 0.00 Negative

12 K-2 D Wall Plaster/Gypsum Intact 0.00 Negative

13 Girls Restroom A Wall Ceramic Tile Intact 0.00 Negative

14 Girls Restroom B Wall Ceramic Tile Intact 0.00 Negative

15 Girls Restroom C Wall Ceramic Tile Intact 0.00 Negative

16 Girls Restroom D Wall Ceramic Tile Intact 0.00 Negative

17 Boys Restroom A Wall Ceramic Tile Intact 0.00 Negative

18 Boys Restroom B Wall Ceramic Tile Intact 0.00 Negative

19 Boys Restroom C Wall Ceramic Tile Intact 0.00 Negative

20 Boys Restroom D Wall Ceramic Tile Intact 0.00 Negative

Lead Inspection Sampling Log 7961 Tamarind Ave, Fontana, CA 92336

File details come from the government source that posted it. Updated .