ENERGY MARKETING COMPANY INC PERMIT U-72-83 PROJECT PLANS (1).pdf

PDF 8 MB Posted

Attached to
OSR Energy Marketing Co. Inc U-72-83 Wetlands Project
Solicitation number
ARFQ 0313 DEP2400000048 3
Issued by
Barbour County, West Virginia

About this file

This file comprises project plans for a wetland reclamation and treatment facility project submitted by Energy Marketing Company Inc. under Permit U-72-83 to the West Virginia Department of Environmental Protection (WVDEP), Division of Land Restoration, Office of Special Reclamation, located in Barbour County, West Virginia. The project involves comprehensive site development including wetland excavation (2,500 cubic yards), new road construction with base and final layers, revegetation efforts, installation of sediment and erosion control measures, and construction of water management infrastructure including treatment ponds, distribution boxes, level control boxes, flow control boxes, bypass manholes, and an extensive piping network utilizing SDR-35 and HDPE materials in various sizes (8-inch through 18-inch). The project plans specify detailed quantities for materials and labor, including 1,500 linear feet each of new road base layer and road bore, 600 linear feet of farm fence with gates, 840 linear feet of grass-lined ditch, 650 linear feet of grouted trapezoidal ditch, 21,000 linear feet of SDR-35 18-inch pipe, and irrigation system installation with oscillating sprinklers serving 12 designated wetland areas. The project was registered in September 2023 and includes comprehensive technical specifications, structural notes, sediment and erosion control details, pipe profiles, ditch details, fence specifications, and project signage requirements.

The project includes specific technical requirements for electrical work mandating West Virginia-licensed contractors with minimum five years' experience in water treatment facility installations, master electrician supervision, and compliance with the National Electrical Code. Contractor responsibilities encompass utility location verification through WV 811, maintenance of working storm drainage systems throughout construction, handling of bench mark locations, and verification of all plan dimensions prior to material ordering. The project involves coordination with multiple state and federal agencies including WVDNR, WVSHPO, USFWS, USEPA, USACE, USNRCS, ACHP, USDA Forest Service, and the Office of Surface Mining for observation and monitoring. Funding is provided through the Special Reclamation Coal Tax paid by West Virginia coal mine companies. The project plans establish that any existing pipes removed during construction become WVDEP property, and the contractor bears responsibility for removal, disposal, and backfill costs included in the site preparation line item. All concrete work must achieve minimum 4,000 PSI compressive strength at twenty-eight days unless otherwise specified, and grout applications require 2,000 PSI unless noted otherwise.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LOCATION MAP

WEST VIRGINIA COUNTY HIGHWAY MAP

VICINITY MAP

CENTURY USGS 7.5' QUADRANGLE

BARBOUR COUNTY, WEST VIRGINIA

OFFICE OF SPECIAL RECLAMATION

DIVISION OF LAND RESTORATION

West Virginia Department of Environmental Protection

HAROLD D. WARD, CABINET SECRETARY

PROJECT

AREA

BARBOUR

COUNTY

LAT. 39° 6' 7" N

PROJECT

AREA

PROJECT

AREA

ENERGY MARKETING COMPANY INC

PRESTON COUNTYLONG. 80° 12' 23" W

STATE OF

NOS I

EF

RP O W

TSE

S

E NLA

REENI NGRV I

AI

G I

19237

LA

RRY L . R I GGLEMANREG I STERED

SEPTEMBER 2023

DRAWING INDEX

DESCRIPTION SHEET NO. DESCRIPTION SHEET NO.

TITLE PAGE 01

TAX MAP 02

SUMMARY OF QUANTITIES 03

GENERAL AND STRUCTURAL NOTES 04

SEDIMENT AND EROSION CONTROL 05

EXISTING CONDITIONS 06

DESIGN PLAN OVERVIEW 07 - 10

PROJECT DETAILS 11 - 17

PIPE PROFILES 18 - 21

DITCH DETAILS 22

MISCELLANEOUS DETAILS 23

FENCE DETAILS 24

PROJECT SIGN 25

PERMIT # U-72-83

WETLAND PROJECT

AutoCAD SHX Text

HANCOCK

AutoCAD SHX Text

BROOKE

AutoCAD SHX Text

OHIO

AutoCAD SHX Text

MARSHALL

AutoCAD SHX Text

PRESTON

AutoCAD SHX Text

MORGAN

AutoCAD SHX Text

MONONGALIA

AutoCAD SHX Text

WETZEL

AutoCAD SHX Text

MINERAL

AutoCAD SHX Text

BERKELEY

AutoCAD SHX Text

MARION

AutoCAD SHX Text

TYLER

AutoCAD SHX Text

HAMPSHIRE

AutoCAD SHX Text

JEFFERSON

AutoCAD SHX Text

PLEASANTS

AutoCAD SHX Text

HARRISON

AutoCAD SHX Text

TAYLOR

AutoCAD SHX Text

DODDRIDGE

AutoCAD SHX Text

WOOD

AutoCAD SHX Text

RITCHIE

AutoCAD SHX Text

GRANT

AutoCAD SHX Text

BARBOUR

AutoCAD SHX Text

TUCKER

AutoCAD SHX Text

HARDY

AutoCAD SHX Text

WIRT

AutoCAD SHX Text

LEWIS

AutoCAD SHX Text

RANDOLPH

AutoCAD SHX Text

UPSHUR

AutoCAD SHX Text

GILMER

AutoCAD SHX Text

JACKSON

AutoCAD SHX Text

CALHOUN

AutoCAD SHX Text

MASON

AutoCAD SHX Text

PENDLETON

AutoCAD SHX Text

ROANE

AutoCAD SHX Text

BRAXTON

AutoCAD SHX Text

POCAHONTAS

AutoCAD SHX Text

WEBSTER

AutoCAD SHX Text

PUTNAM

AutoCAD SHX Text

CLAY

AutoCAD SHX Text

KANAWHA

AutoCAD SHX Text

CABELL

AutoCAD SHX Text

NICHOLAS

AutoCAD SHX Text

WAYNE

AutoCAD SHX Text

LINCOLN

AutoCAD SHX Text

GREENBRIER

AutoCAD SHX Text

FAYETTE

AutoCAD SHX Text

BOONE

AutoCAD SHX Text

LOGAN

AutoCAD SHX Text

RALEIGH

AutoCAD SHX Text

MINGO

AutoCAD SHX Text

SUMMERS

AutoCAD SHX Text

WYOMING

AutoCAD SHX Text

MONROE

AutoCAD SHX Text

MERCER

AutoCAD SHX Text McDOWELL

AutoCAD SHX Text

ENGINEER

AutoCAD SHX Text LARRY L. RIGGLEMAN, MSE, PE WEST VIRGINIA PROFESSIONAL ENGINEER REGISTRATION NUMBER 19237

TAX MAP

TOTAL

SHT. NO.

OFFICE OF SPECIAL RECLAMATION

SCALE: NTS

47 SCHOOL STREET, SUITE 301

PHILIPPI, WV 26416

OFFICE: 1-304-457-3219

FAX: 1-304-457-5613

Division of Land Restoration Office of Special Reclamation

West Virginia Department of Environmental Protection

DATE: SEPTEMBER 2023

ENERGY MARKETING COMPANY INC.

PERMIT # U-72-83

BARBOUR COUNTY, WEST VIRGINIA

AutoCAD SHX Text 25.1

AutoCAD SHX Text

KRISTEN HIBBS

AutoCAD SHX Text

DB535/PG633

AutoCAD SHX Text

ROUTE 20

AutoCAD SHX Text

ROUTE 20

AutoCAD SHX Text

5.73 ACRES

AutoCAD SHX Text 22.4

AutoCAD SHX Text

HEARLON & DOROTHY

AutoCAD SHX Text

DB382/PG55

AutoCAD SHX Text

1.03 ACRES

AutoCAD SHX Text 25.2

AutoCAD SHX Text

KRISTEN HIBBS

AutoCAD SHX Text

DB535/PG633

AutoCAD SHX Text

1.00 ACRES

AutoCAD SHX Text

RADCLIFF

AutoCAD SHX Text

AutoCAD SHX Text

S&B RESOURCES LLC

AutoCAD SHX Text

DB429/PG263

AutoCAD SHX Text

71.11 ACRES

AutoCAD SHX Text

AutoCAD SHX Text

S&B RESOURCES LLC

AutoCAD SHX Text

DB429/PG263

AutoCAD SHX Text

0.09 ACRES

AutoCAD SHX Text

AutoCAD SHX Text

S&B RESOURCES LLC

AutoCAD SHX Text

DB429/PG263

AutoCAD SHX Text

21.63 ACRES

AutoCAD SHX Text 22.3

AutoCAD SHX Text

AutoCAD SHX Text 22.5

AutoCAD SHX Text

BRADLEY & MICHELLE

AutoCAD SHX Text

DB431/PG598

AutoCAD SHX Text

1.10 ACRES

AutoCAD SHX Text

DAHLHEIM

AutoCAD SHX Text

TRACIE L. BURR

AutoCAD SHX Text

DBFB12/PG316

AutoCAD SHX Text

0.45 ACRES

AutoCAD SHX Text

MARK & KRISTEN

AutoCAD SHX Text

DB418/PG612

AutoCAD SHX Text

3.14 ACRES

AutoCAD SHX Text 22.1

AutoCAD SHX Text

MEDLOCK

AutoCAD SHX Text

MARK & KRISTEN

AutoCAD SHX Text

DB481/PG511

AutoCAD SHX Text

0.86 ACRES

AutoCAD SHX Text

MEDLOCK

AutoCAD SHX Text

NOTE: TAX MAP IS FOR REFERENCE PURPOSES ONLY.

PROJECT AREA

THE QUANTITIES SHOWN ON THE SUMMARY OF QUANTITIES REPRESENT THE AMOUNTS AS

DIRECTLY MEASURED IN THE PLANS. WHEN BIDDING IN WVOASIS THE COMMODITY LINES MAY BE

DIFFERENT AMOUNTS FROM THE PLANS TO ACCOMMODATE ANY UNFORESEEN CHANGES IN THE

FIELD. THEREFORE, ALWAYS BID ON THE QUANTITIES LISTED IN WVOASIS.

TECHNICAL SPECIFICATIONS DESCRIPTION QUANTITY UNIT

WETLAND EXCAVATION6-5, 6-6 2500 CY

LF

AC

TN

EA

LB

CF

CY

LF

LF

LF

LF

LF

LF

EA

EA

EA

EA

EA

EA

LF

LF

LF

LF

EA

EA

21000

EA

EA

EA

EA

EA

LF

NEW ROAD CONSTRUCTION BASE LAYER5-3, 7-1, 8-4

ROAD BORE10-23

REVEGETATION TYPE 16-1

HAYBALES6-2

INCIDENTAL STONE7-1, 7-3

FARM FENCE WITH GATES5-6

GRASS LINED DITCH6-1, 6-5

GROUTED TRAPEZOIDAL DITCH7-1, 9-4

L20 GROUTED OUTLET

BYPASS MANHOLE TYPE 19-2

BYPASS MANHOLE TYPE 2

LEVEL CONTROL BOX

FLOW CONTROL BOX

DISTRIBUTION BOX

POND OUTLET VAULT

SDR 35 18 INCH PIPE10-14

SDR 35 12 INCH PIPE

SDR 35 8 INCH PIPE

HDPE DR 17 18 INCH PIPE

HEADWALL

MANHOLE

WETLAND GRASS6-6

WETLAND ORGANIC AMENDMENT6-6

WETLAND STRAW MULCH BALE6-1

POND 2 RECLAMATION6-5

IRRIGATION SYSTEM13-7

CATCH BASIN

18 INCH HDPE DUAL WALL CULVERT10-16

PIPE ANCHOR BLOCKS

PRECAST CONCRETE BLOCK ANCHOR

NEW ROAD CONSTRUCTION FINAL LAYER5-3, 7-1, 8-4

7-1, 9-4

9-2 9-2 9-2 9-2 9-2

10-14 10-14 10-15 9-2 9-2

9-1 9-2

9-2

SUMMARY OF QUANTITIES

TOTAL

SHT. NO.

OFFICE OF SPECIAL RECLAMATION

SCALE: NTS

47 SCHOOL STREET, SUITE 301

PHILIPPI, WV 26416

OFFICE: 1-304-457-3219

FAX: 1-304-457-5613

Division of Land Restoration Office of Special Reclamation

West Virginia Department of Environmental Protection

DATE: SEPTEMBER 2023

ENERGY MARKETING COMPANY INC.

PERMIT # U-72-83

BARBOUR COUNTY, WEST VIRGINIA

SEDIMENT AND EROSION CONTROL

THE FIRST ORDER OF WORK FOR THE CONTRACTOR IS TO INSTALL SEDIMENT

CONTROL STRUCTURES TO ESTABLISH EROSION CONTROL AT THE EARLIEST POSSIBLE

DATE. INITIAL CLEARING AND GRUBBING IS TO ONLY BE WHAT IS NECESSARY IN

ORDER TO ACCOMPLISH THESE OPERATIONS.

WVDEP SHALL CONDUCT PERIODIC INSPECTION OF SEDIMENT AND EROSION CONTROL

MEASURES TO INSURE PROPER OPERATION AND COMPLIANCE.

IN THE EVENT THAT THE TEMPORARY EROSION AND POLLUTION CONTROL MEASURES

ARE ORDERED BY THE PROJECT CONTACT DUE TO THE CONTRACTOR'S NEGLIGENCE,

CARELESSNESS, OR FAILURE TO INSTALL PERMANENT CONTROLS AS PART OF THE

WORK AS SCHEDULED, SUCH WORK SHALL BE PERFORMED BY THE CONTRACTOR AT

THE CONTRACTOR'S EXPENSE.

WASTE AND BORROW SITES

WHEN REQUIRED, WASTE AND BORROW SITES SHALL BE DEPICTED ON THE PROJECT

PLANS. DURING THE CONTRACT, IF ADDITIONAL WASTE AND BORROW SITES ARE

REQUIRED, THE CONTRACTOR SHALL CONTACT THE PROJECT CONTACT.

NO WASTE OR BORROW SITES SHALL BE PERMITTED WITHIN ANY FLOODPLAIN,

WETLANDS, OR HIGHLY SENSITIVE CULTURAL RESOURCES.

EXISTING PIPE REMOVAL

ANY EXISTING PIPES THAT ARE REMOVED DURING CONSTRUCTION SHALL BECOME

THE PROPERTY OF THE WVDEP, UNLESS OTHERWISE NOTED. THE COST OF THE

REMOVAL OF EXISTING PIPES SHALL BE INCLUDED IN THE COMMODITY LINE ITEM "SITE

PREPARATION" AND SHALL INCLUDE REMOVAL, DISPOSAL, AND BACKFILL WITH

SUITABLE MATERIAL.

CONSTRUCTION ENTRANCE AND ROADS

CONSTRUCTION ENTRANCE(S) SHALL BE INSTALLED AT THE LOCATION(S) SHOWN ON

THE PROJECT PLANS.

THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING THE ROADS IN A CLEAN

AND DUST FREE CONDITION.

AGGREGATE BASE COURSE SHALL BE APPLIED IMMEDIATELY FOLLOWING ROUGH

GRADING PER PROJECT PLAN DETAILS.

ELECTRICAL

THE CONTRACTOR SHALL FOLLOW ALL LATEST LOCAL, STATE, AND FEDERAL

ELECTRICAL CODES, INCLUDING THE NATIONAL ELECTRICAL CODE (NEC).

ALL ELECTRICAL WORK PERFORMED SHALL BE EITHER COMPLETED BY OR UNDER THE

DIRECT SUPERVISION OF A MASTER ELECTRICIAN.

THE GENERAL CONTRACTOR OR AN ELECTRICAL SUBCONTRACTOR SHALL BE

LICENSED IN THE STATE OF WEST VIRGINIA TO PERFORM ELECTRICAL WORK. THE

COMPANY PERFORMING THE ELECTRICAL WORK SHALL HAVE A MINIMUM OF FIVE (5)

YEARS OF EXPERIENCE IN THE INSTALLATION OF ELECTRICAL SYSTEMS FOR WATER

TREATMENT FACILITIES. THE COMPANY MAY EMPLOY WEST VIRGINIA LICENSED

JOURNEYMAN ELECTRICIANS WORKING UNDER THE SUPERVISION OF THE MASTER

ELECTRICIAN. HOWEVER, NO MORE THAN ONE APPRENTICE PER JOURNEYMAN SHALL

BE PERMITTED.

UTILITIES

THE LOCATIONS OF ALL KNOWN UTILITIES ARE SHOWN ON THE PROJECT PLANS AND

FIELD INFORMATION. THE CONTRACTOR IS RESPONSIBLE TO ASCERTAIN THE STATUS

AND LOCATION OF EACH UTILITY WHEN PERFORMING WORK WHICH MAY AFFECT THE

FACILITIES, INCLUDING CALLING WV 811, PROBING, EXCAVATION, OR ANY OTHER

PRECAUTION REQUIRED TO CONFIRM LOCATION. THE CONTRACTOR WILL BE

RESPONSIBLE FOR ANY DAMAGE OR DISRUPTION TO UTILITY LINES WHICH ARE KNOWN

ACTIVE AND ARE TO REMAIN IN OPERATION.

DRAINAGE

THE CONTRACTOR SHALL MAINTAIN WORKING STORM DRAINAGE SYSTEMS THROUGH THE WORK

AREAS AT ALL TIMES DURING CONSTRUCTION. THE WORKING SYSTEM MAY CONSIST OF THE

EXISTING STORM DRAINAGE SYSTEM, THE PROPOSED STORM DRAINAGE SYSTEM OR COMBINATION

THEREOF.

BENCH MARKS

THE CONTRACTOR SHALL BE RESPONSIBLE FOR HOLDING BENCH MARK LOCATIONS THROUGHOUT

THE LIFE OF THE CONTRACT. IN THE EVENT THAT A BENCH MARK IS DISTURBED, THE

CONTRACTOR, AS DIRECTED BY THE PROJECT CONTACT, WILL RELOCATE OR RE-ESTABLISH THE

BENCH MARK. NO ADDITIONAL PAYMENT OR COMPENSATION WILL BE MADE FOR THIS WORK.

VERIFICATION OF DIMENSIONS

THE CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALL PLAN AND ELEVATION DIMENSIONS

PRIOR TO ORDERING MATERIALS FOR THE CONSTRUCTION OF THE VARIOUS COMMODITY LINE

ITEMS IN THIS CONTRACT.

NOTICE TO CONTRACTORS

REPRESENTATIVES OF THE FOLLOWING STATE AND FEDERAL AGENCIES MAY BE IN THE AREA ON

OCCASION TO OBSERVE, INSPECT AND MONITOR THE CONSTRUCTION ACTIVITIES:

WEST VIRGINIA DEPARTMENT OF ENVIRONMENTAL PROTECTION, (WVDEP)

WEST VIRGINIA DIVISION OF NATURAL RESOURCES, (WVDNR)

WEST VIRGINIA STATE HISTORIC PRESERVATION OFFICE, (WVSHPO)

UNITED STATES FISH AND WILDLIFE SERVICES, (USFWS)

UNITED STATES ENVIRONMENTAL PROTECTION AGENCY, (USEPA)

UNITED STATES ARMY CORPS OF ENGINEERS, (USACE)

UNITED STATES NATURAL RESOURCES CONSERVATION SERVICE,(USNRCS)

ADVISORY COUNCIL OF HISTORIC PRESERVATION, (ACHP)

UNITED STATES DEPARTMENT OF AGRICULTURE, FOREST SERVICE, (USDA, FS)

OFFICE OF SURFACE MINING (OSM)

SHOP DRAWINGS

SHOP DRAWINGS SHALL BE SENT TO THE ATTENTION OF THE PROJECT CONTACT.

GEOTECHNICAL REPORT

WHEN SITE CONDITIONS REQUIRE A GEOTECHNICAL REPORT, REFER TO TECHNICAL SPECIFICATION

SECTION 14-1 GEOTECHNICAL REPORT. ANY INQUIRIES SHALL BE DIRECTED TO THE PROJECT

CONTACT.

ELEVATIONS

ALL ELEVATIONS SHOWN REFER TO THE NORTH AMERICAN VERTICAL DATUM OF 1988. (NAD88)

COORDINATES

THE PROJECT PLAN DATUMS ARE BASED UPON THE NORTH OR SOUTH ZONE OF THE WEST

VIRGINIA STATE PLANE SYSTEM. THE HORIZONTAL DATUM IS BASED ON THE NORTH\

AMERICAN DATUM OF 1983 (NAD 83). GRID FACTORS ARE NOT REQUIRED WHEN MAKING FIELD

MEASUREMENTS.

CROSS-SECTION VIEWS

ALL CROSS SECTIONS ARE TO BE VIEWED IN THE DIRECTION OF THE ARROW.

VIEWING DIRECTION

FOUNDATIONS

1. THE CONTRACTOR SHALL REVIEW THE SUBSURFACE INVESTIGATION

REPORT, IF AVAILABLE, BEFORE THE START OF CONSTRUCTION.

2. THE CONTRACTOR SHALL NOT PLACE ANY FOUNDATION UNTIL THE

SUBGRADE HAS BEEN ACCEPTED BY THE PROJECT CONTACT.

STRUCTURAL STEEL

1. ALL STEEL SHALL CONFORM TO THE AISC "SPECIFICATIONS FOR THE

DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR

BUILDINGS", LATEST EDITION.

2. WELDED CONNECTIONS SHALL CONFORM TO THE LATEST EDITION OF

AMERICAN WELDING SOCIETY, AWS D1.1.

3. ALL EXTERIOR STRUCTURAL STEEL SHALL BE PAINTED IN ACCORDANCE

WITH TECHNICAL SPECIFICATION SECTION 13-15 PAINTING METAL

STRUCTURES.

CAST-IN-PLACE CONCRETE

1. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT

TWETNY-EIGHT (28) DAYS OF FOUR THOUSAND (4,000) PSI UNLESS OTHERWISE

NOTED.

2. ALL CONCRETE WORK SHALL BE CONSTRUCTED IN ACCORDANCE WITH

"BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" ACI 350-01.

3. ALL EMBEDDED ITEMS ARE NOT SHOWN ON THE PROJECT PLANS. THE

CONTRACTOR SHALL REVIEW THE PROJECT PLANS OF THE VARIOUS TRADES

AND COORDINATE PLACEMENT OF EMBEDDED ITEMS.

4. CONSTRUCTION JOINTS ARE SHOWN ON THE PROJECT PLANS. ANY CHANGES

OR ADDITIONS SHALL BE SUBMITTED TO THE PROJECT CONTACT BEFORE

CONCRETE PLACEMENT. USE TWO (2) INCH X FOUR (4) INCH KEY FOR LESS

THAN EIGHTEEN (18) INCH WALL OR SLAB THICKNESS AND TWO (2) INCH X SIX

(6) INCH KEY FOR THICKNESS OF EIGHTEEN (18) INCHES AND GREATER.

5. PROVIDE FORM COVER WITH A MINIMUM OF TWO (2) INCH OF CONCRETE FROM

THE OUTSIDE SURFACE. TIES FOR WALLS SUBJECT TO HYDROSTATIC

PRESSURE SHALL HAVE WATERSTOPS.

6. PROVIDE ROUGH BROOM FINISH FOR EXTERIOR SLABS AND STEEL TROWEL

FINISH FOR INTERIOR SLABS UNLESS NOTED OTHERWISE.

REINFORCING STEEL

1. ASTM, A615, A616, OR A617, GRADE 60, MINIMUM YIELD STRENGTH SIXTY

THOUSAND (60,000) PSI.

2. REINFORCING DETAILS SHALL CONFORM TO ACI "DETAILING MANUAL - 1994"

OR AS SHOWN ON THE PROJECT PLANS.

3. MINIMUM BAR LAPS

TOP OTHER

#9 BAR 90 INCHES 65 INCHES

#8 BAR 71 INCHES 51 INCHES

#7 BAR 54 INCHES 39 INCHES

#6 BAR 43 INCHES 31 INCHES

#5 BAR 36 INCHES 26 INCHES

#4 BAR 28 INCHES 20 INCHES

4. MINIMUM CLEARANCE

a. CAST AGAINST EARTH - 3"

b. #6 BARS AND LARGER - 2"

c. #5 BARS AND SMALLER - 2"

STRUCTURAL LINTELS

UNLESS SHOWN OTHERWISE, PROVIDE THE FOLLOWING LINTEL ANGLES:

MASONRY OPENING ANGLE & SIZE BEARING

4'-0" TO LESS (2) 3 12 X 3 12 X 5

16 6"

4'-1" TO 6'-0" (2) 4 X 3 12 X 5

16 LLV 6"

6'-1" TO 7'-0" (2) 5 X 3 12 X 38 LLV 6"

7'-1" TO 3'-0" (2) 6 X 3 12 X 38 LLV 6"

8'-1" TO 9'-0" (2) 7 X 4 X 38 LLV 6"

1. ALL LINTELS SHALL BE GALVANIZED.

2. ALL LINTELS SHALL HAVE TWELVE (12) INCHES OF SOLID MASONRY BELOW

BEARING END.

BLOCK CONSTRUCTION

1. MASONRY WORK SHALL CONFORM TO THE LATEST EDITION OF THE "NATIONAL

CONCRETE MASONRY ASSOCIATION."

2. HOLLOW LOAD-BEARING CONCRETE MASONRY UNITS SHALL MEET THE

REQUIREMENTS OF ASTM C90 AND HAVE A TWO (2) HOUR FIRE RATING.

3. MORTAR SHALL BE TYPE S IN ACCORDANCE WITH ASTM C-270 AND HAVE A

MINIMUM COMPRESSIVE STRENGTH OF ONE THOUSAND EIGHT HUNDERED

(1,800) PSI AT TWENTY-EIGHT (28) DAYS, GROUT SHALL HAVE A MINIMUM

COMPRESSIVE STRENGTH OF TWO THOUSAND FIVE HUNDRED (2,500) PSI AT

TWENTY-EIGHT (28) DAYS.

4. REINFORCING STEEL SHALL BE ASTM, A615, A616, OR A617 YIELD GRADE 60.

MINMUM STRENGTH SIXTY THOUSAND (60,000) PSI.

5. REINFORCING STEEL SHALL BE LAPPED AS SPECIFIED ON THIS SHEET. (REF

REINFORCING STEEL, SUB 3)

6. BLOCK MANUFACTURER SHALL PROVIDE A CONTROL JOINT DETAIL TO BE

REVIEWED AND APPROVED BY THE PROJECT CONTACT DURING

CONSTRUCTION.

GENERAL NOTES STRUCTURAL NOTES

GENERAL AND STRUCTURAL NOTES

TOTAL

SHT. NO.

GENERAL STEEL NOTES

1. STEEL FABRICATION AND ERECTION SHALL COMPLY WITH THE LATEST EDITIONS

OF THE FOLLOWING CODES & STANDARDS:

A. AMERICAN INSITUTE OF STEEL CONSTRUCTION (AISC) SPECIFICATION FOR

STRUCTURAL STEEL BUILDINGS.

B. RESEARCH COUNCIL ON STRUCTURAL CONNECTIONS (RCSC) SPECIFICATION

FOR STRUCTURAL STEEL JOINTS USING HIGH-STRENGTH BOLTS.

C. WELDING AS PER AMERICAN WELDING SOCIETY (AWS) D1.1 "STRUCTURAL

WELDING CODE.

D. STATE BUILDING CODE - LATEST EDITION.

E. FEDERAL REGULATIONS OT THE OCCUPATIONAL SAFETY AND HEALTH

ADMINISTRATION (OSHA) OF THE U.S. DEPARTMENT OF LABOR, TITLE 29.

F. ASTM INTERNATIONAL (ASTM) A992 STANDARD SPECIFICATION FOR

STRUCTURAL STEEL SHAPES.

G. ASTM A36 STANDARD SPECIFICATION FOR CARBON STEEL STRUCTURAL

STEEL.

H. PAINTING TO BE IN ACCORDANCE WITH THE SSPC PAINTING MANUAL:

1. VOLUME 1 - GOOD PAINTING PRACTICE

2. VOLUME 2 - SYSTEMS AND SPECIFICATIONS.

2. C SHAPES & ANGLE SHALL BE ASTM A992.

3. ALL OTHER PLATES AND SHAPES SHALL BE ASTM A36.

4. BOLT ASSEMBLY SHALL BE 3/4" ASTM F3125, GRADE A325 BOLTS; ASTM A563 NUTS,

GRADE C PLAIN; ASTM F436 WASHER, PLAIN.

5. THE STRUCTURAL STEEL DETAILER IS RESPONSIBLE FOR THE DESIGN OF ALL

CONNECTIONS, EXCEPT THOSE SPECIFICALLY SHOWN ON THE DESIGN DRAWINGS.

6. ALL BOLTED CONNECTIONS SHALL BE FULLY PRE TENSIONED.

7. ALL BOLTED CONNECTIONS SHALL HAVE A MINIMUM OF TWO (2) BOLTS.

8. FABRICATOR SHALL FURNISH ALL FIELD BOLTS, NUTS AND WASHERS NECESSARY.

9. WHERE FIELD WELD IS SPECIFIED, THE FABRICATOR SHALL FURNISH ALL

NECESSARY CLIPS AND BOLTS.

10. ALL GRATING TO BE MOLDED FIBERGLASS AS MANUFACTURED BY MCNICHOLS OR

EQ.

A. SERIES TYPE TO BE MS-S-150.

B. CONSTRUCTION TYPE TO BE MOLDED

C. GRID SHAPE TO BE SQUARE.

D. PRIMARY MATERIAL TO BE FIBERGLASS

E. RESIN TO BE SGF POLYESTER RESIN (SGF)

F. GRID SIZE TO BE 1 1/2" x 1 1/2" ON CENTER.

G. GRID HEIGHT TO BE 1 1/2".

H. GRID THICKNESS TO BE 1/4".

I. COLOR TO BE YELLOW.

J. GRATING SHALL BE ATTACHED WITH STAINLESS STEEL, TYPE 316 FRICTION

TYPE GRATING CLIPS.

OFFICE OF SPECIAL RECLAMATION

SCALE: NTS

47 SCHOOL STREET, SUITE 301

PHILIPPI, WV 26416

OFFICE: 1-304-457-3219

FAX: 1-304-457-5613

Division of Land Restoration Office of Special Reclamation

West Virginia Department of Environmental Protection 04ENERGY MARKETING COMPANY INC.

BARBOUR COUNTY, WEST VIRGINIA 25DATE: SEPTEMBER 2023

OUTLET CROSS-SECTIONUP-SLOPE FACE

R3-ROCK

AASHTO #57

6" MIN.

1 MIN.

1 MIN.

FILTER FABRIC OR

STRAW BALESWOOD POSTS

1 MIN.

HEIGHT OF ROCK FILTER = 5/6

HEIGHT OF FILTER FABRIC FENCE

OR STRAW BALES

3' MIN.

AASHTO #57

% SLOPE

L

1'

3"

FLOW

RUN

R

IS

E

9"

3" MIN.

SECTION A-A' SECTION C-C'

NOTE:

1. SPACING OF PREFABRICATED DITCH CHECKS

SHALL BE THE SAME AS STONE DITCH CHECKS.

2. AASHTO #1 (2-4 INCH) SHALL BE USED, AND MAY

BE REINFORCED WITH 3 TO 6 INCH RIPRAP.

3. THE MINIMUM DITCH DEPTH IS 1.0'.DITCH MAY BE

TRAPEZOIDAL OR V-DITCH.

A

A'

C

C'

LL= (160/S), WITH A 100' MAX

WHERE,

L= SPACING IN FEET

S= % SLOPE= (RISE/RUN) X 100

9"

3" MIN.

ROCK CHECK DAM

NTS

3"

2"-5"

12"

6"

2.4.

5.

3B.

1.

3A.

CRITICAL POINTS

A. OVERLAPS AND SEAMS

B. PROJECTED WATER LINE

C. CHANNEL BOTTOM/SIDE

SLOPE VERTICES

* HORIZONTAL STAPLE SPACING SHOULD BE ALTERED

IF NECESSARY TO ALLOW STAPLES TO SECURE THE

CRITICAL POINTS ALONG THE CHANNEL SURFACE.

A

A

B C

B C

** IN LOOSE SOIL CONDITIONS, THE USE OF STAPLE

OR STAKE LENGTHS GREATER THAN 6" MAY BE

12"

6"

6"

6"

4"-6"

4"

(15 cm)

NOTE:

NECESSARY TO PROPERLY ANCHOR THE BLANKETS.

4"

2"-5"1.

6.

7.

2.

5.

4.8.

3.

6"

" M

IN

4" MIN

FLOW

EMBED FILTER FABRIC

MIN. 6" INTO GROUND

FILTER FABRIC

FILTER FABRIC

THE FENCE POSTS AND EXTEND

IT INTO THE DITCH.

EXTENSION OF FABRIC INTO TRENCH

FENCE POST

THE EXCAVATED SOIL.

48" MIN. FENCE

OF FILTER ABOVE

GROUND SURFACE

30" MIN. HEIGHT

FLOW

FLOW

10' MAX. C/O2. ATTACH THE FILTER FABRIC TO

A 4" X 4" TRENCH UPSLOPE

ALONG THE LINE OF POSTS.

1. SET POSTS AND EXCAVATE 3. BACKFILL AND COMPACT

POST

48" HIGH (MIN.) FENCE POSTS

NOTE:

SILT FENCE SHALL BE INSTALLED IN THE LOCATIONS SHOWN ON THE PROJECT PLANS AND IN

ACCORDANCE WITH THE DRAWING DETAILS SHOWN:

1. A TRENCH SHALL BE PLOWED OR OTHERWISE EXCAVATED TO THE REQUIRED DEPTH

WITH LITTLE, IF ANY, DISTURBANCE TO THE DOWN SLOPE SIDE OF THE TRENCH. THE

BOTTOM OF THE TRENCH AND THE FENCE TOP SHALL BE PLACED ON A LEVEL GRADE.

WHEN IT IS NECESSARY TO CROSS SMALL DEPRESSIONS, THE TRENCH BOTTOM AND

FENCE TOP MAY DEVIATE SLIGHTLY FROM THE LEVEL GRADE. GRADES IN SUCH

SECTIONS WILL NOT EXCEED 1%, NOR WILL THE DEVIATION EXTEND

FOR MORE THEN TWENTY-FIVE (25) FEET.

2. SUPPORT STAKES WILL BE DRIVEN TO THE REQUIRED DEPTH BELOW THE EXISTING

GROUND SURFACE AT THE SPECIFIED INTERVALS.

3. STRETCH AND FASTEN FABRIC TO THE UP-SLOPE SIDE OF THE SUPPORT STAKES.

4. WHERE THE ENDS OF THE FABRIC COME TOGETHER, THEY BE BE OVERLAPPED,

FOLDED, AND STAPLED TO PREVENT SEDIMENT BYPASS.

5. THE TOE ANCHOR WILL BE BACKFILLED AND COMPACTED TO A DENSITY EQUAL TO THE

SURROUNDING SOILS.

6. FILTER FABRIC IS TO BE FASTENED SECURELY TO POSTS WITH WIRE TIES OR STAPLES.

7. WHEN TWO SECTIONS OF FILTER FABRIC ADJOIN EACH OTHER, THEY SHALL BE

OVERLAPPED BY SIX INCHES AND FOLDED.

8. MAINTENANCE SHALL BE PERFORMED AS NEEDED AND INSPECTED FOR DAMAGE

AFTER RAINS.

9. POSTS SHALL BE CONSTRUCTED OF TWO (2) INCH X TWO (2) INCH HARDWOOD, THREE

(3) FEET LONG.

10. APPROVED PREFABRICATED UNITS INCLUDE "GEOFAB", "ENVIROFENCE", OR APPROVED

EQUAL.

11. REFER TO TECHNICAL SPECIFICATION SECTION 6-2 SEDIMENT CONTROL FOR MORE

DETAILS.

1. PREPARE SOIL BEFORE INSTALLATION BLANKETS, INCLUDING ANY NECESSARY APPLICATION OF LIME, FERTILIZER, AND SEED. WHEN USING

EROSION MATTING.

2. BEGIN AT THE TOP OF THE CHANNEL BY ANCHORING THE BLANKET IN A SIX (6) INCH DEEP X SIX (6) INCH WIDE TRENCH THAT WITH APPROXIMATELY TWELVE (12) INCHES OF BLANKET EXTENDED BEYOND THE UP-SLOPE PORTION OF THE TRENCH. ANCHOR THE BLANKET WITH A ROW OF STAPLES/STAKES APPROXIMATELY TWELVE (12) INCHES APART IN THE BOTTOM OF THE TRENCH. BACKFILL AND COMPACT THE TRENCH AFTER STAPLING. APPLY SEED TO COMPACTED SOIL AND FOLD REMAINING TWELVE (12) INCH PORTION OF BLANKET BACK OVER SEED AND COMPACTED SOIL. SECURE BLANKET OVER COMPACTED SOIL WITH A ROW OF STAPLES/STAKES SPACED APPROXIMATELY

TWELVE (12) INCHES ACROSS THE WIDTH OF THE BLANKET.

3. ROLL CENTER BLANKET IN DIRECTION OF WATER FLOW IN BOTTOM OF CHANNEL. BLANKETS WILL UNROLL WITH APPROPRIATE SIDE AGAINST THE SOIL SURFACE. ALL BLANKETS MUST BE SECURELY FASTENED TO THE SOIL SURFACE BY PLACING STAPLES/STAKES IN APPROPRIATE LOCATIONS AS SHOWN IN THE STAPLE PATTERN GUIDE. WHEN USING THE DOT SYSTEM, STAPLES/STAKES SHOULD BE PLACED THROUGH

EACH OF THE COLORED DOTS CORRESPONDING TO THE APPROPRIATE STAPLE PATTERN.

4. PLACE CONSECUTIVE BLANKETS END OVER END (SHINGLE STYLE) WITH A FOUR (4) INCH TO SIX (6) INCH OVERLAP. USE A DOUBLE ROW OF STAPLES STAGGERED FOUR (4) INCHES APART AND FOUR (4) INCH ON CENTER TO SECURE BLANKETS.

5. FULL LENGTH EDGE OF BLANKETS AT TOP OF SIDE SLOPES MUST BE ANCHORED WITH A ROW OF STAPLES/STAKES APPROXIMATELY TWELVE

(12) INCHES APART IN A SIX (6) INCH DEEP X SIX (6) INCH WIDE TRENCH. BACKFILL AND COMPACT THE TRENCH AFTER STAPLING.

6. ADJACENT BLANKETS MUST BE OVERLAPPED APPROXIMATELY TWO (2) TO FIVE (5) INCHES (DEPENDING ON BLANKET TYPE) AND STAPLED.

7. IN HIGH FLOW CHANNEL APPLICATIONS, A STAPLE CHECK SLOT IS RECOMMENDED AT THIRTY (30) TO FORTY (40) FOOT INTERVALS. USE A

DOUBLE ROW OF STAPLES STAGGERED FOUR (4) INCHES APART AND FOUR (4) INCH ON CENTER THE ENTIRE WIDTH OF THE CHANNEL.

8. THE TERMINAL END OF THE BLANKETS MUST BE ANCHORED WITH A ROW OF STAPLES/STAKES APPROXIMATELY TWELVE (12) INCHES APART IN

A SIX (6) INCH DEEP X SIX (6) INCH WIDE TRENCH. BACKFILL AND COMPACT THE TRENCH AFTER STAPLING.

1. PREPARE SOIL BEFORE INSTALLATION BLANKETS, INCLUDING ANY NECESSARY APPLICATION OF LIME, FERTILIZER, AND SEED. WHEN USING

EROSION MATTING.

2. BEGIN AT THE TOP OF THE CHANNEL BY ANCHORING THE BLANKET IN A SIX (6) INCH DEEP X SIX (6) INCH WIDE TRENCH THAT WITH APPROXIMATELY TWELVE (12) INCHES OF BLANKET EXTENDED BEYOND THE UP-SLOPE PORTION OF THE TRENCH. ANCHOR THE BLANKET WITH A ROW OF STAPLES/STAKES APPROXIMATELY TWELVE (12) INCHES APART IN THE BOTTOM OF THE TRENCH. BACKFILL AND COMPACT THE TRENCH AFTER STAPLING. APPLY SEED TO COMPACTED SOIL AND FOLD REMAINING TWELVE (12) INCH PORTION OF BLANKET BACK OVER SEED AND COMPACTED SOIL. SECURE BLANKET OVER COMPACTED SOIL WITH A ROW OF STAPLES/STAKES SPACED APPROXIMATELY

TWELVE (12) INCHES ACROSS THE WIDTH OF THE BLANKET.

3. ROLL CENTER BLANKET IN DIRECTION OF WATER FLOW IN BOTTOM OF CHANNEL. BLANKETS WILL UNROLL WITH APPROPRIATE SIDE AGAINST THE SOIL SURFACE. ALL BLANKETS MUST BE SECURELY FASTENED TO THE SOIL SURFACE BY PLACING STAPLES/STAKES IN APPROPRIATE LOCATIONS AS SHOWN IN THE STAPLE PATTERN GUIDE. WHEN USING THE DOT SYSTEM, STAPLES/STAKES SHOULD BE PLACED THROUGH

EACH OF THE COLORED DOTS CORRESPONDING TO THE APPROPRIATE STAPLE PATTERN.

4. THE EDGES OF PARALLEL BLANKETS MUST BE STAPLED WITH APPROXIMATELY TWO (2) INCH TO FIVE (5) INCH OVERLAP DEPENDING ON

BLANKET TYPE.

5. CONSECUTIVE BLANKETS SPLICED DOWN THE SLOPE MUST BE PLACED END OVER END (SHINGLE STYLE) WITH AN APPROXIMATE THREE (3) INCH OVERLAP. STAPLE THROUGH OVERLAPPED AREA, APPROXIMATELY TWELVE (12) INCHES APART ACROSS THE ENTIRE BLANKET WIDTH.

6. IN LOOSE SOIL CONDITIONS, THE USE OF STAPLE OR STAKE LENGHTS GREATER THAN SIX (6) INCHES MAY BE NECESSARY TO PROPERLY

SECURE THE BLANKETS.

1' 1'

EROSION MATTING

NTS

ROCK FILTER OUTLETS

NTS

SILT FENCE DETAIL

NTS

CONSTRUCTION DETAIL

INSTALLATION DETAIL

SLOPE INSTALLATION

CHANNEL INSTALLATION

STORAGE TANKCOMPACTED

SOIL COMPACTED

SOIL

10 MIL PLASTIC LINER

EARTHEN BASIN

4 SIDES

LOOSE SAND TO PROTECT

PLASTIC LINER FROM PUNCTURE

BURY "ENDS" OR WEIGHT

TO SECURE LINER (TYP.)

(H) MIN 2'

6'4'

2" SS - NPT

MALE THREAD

2" BANJO BALL VALVE OR

APPROVED EQUIVALENT

SEAL TO LINER BY MEANS

OF MECHANICAL FITTINGS

OR WELDING

SPILL CONTAINMENT DETAIL

NTS

NOTES:

1. SELECTED HEIGHT (H) OF EARTHEN BERM IS TO BE A TWO (2) FOOT MINIMUM OR 110% OF THE CAPACITY OF THE TANK(S) TOTAL VOLUME WITHIN THE BERM. A SIX (6) INCH FREEBOARD MUST BE INCLUDED.

2. A TWO (2) INCH WATER REMOVAL DRAIN SHALL BE LOCATED AT THE LOWEST POINT IN THE BOTTOM OF THE CONTAINMENT VOLUME. IT SHALL CONNECT TO A NORMALLY CLOSED VALVE OUTSIDE THE DIKE.

THE VALVE SHALL BE MANUALLY OPERATED AND PROTECTED FROM UNAUTHORIZED OPERATION.

RAINWATER CONTAINED WITHIN THIS DIKE SHALL BE EXAMINED PRIOR TO RELEASE TO ENSURE THAT HARMFUL QUANTITIES OF FUELS AND LUBRICANTS ARE NOT DISCHARGED. ALTERNATE METHODS OF

WATER REMOVAL WILL BE CONSIDERED FOR APPROVAL.

3. TANKS WITH SECONDARY CONTAINMENT MAY BE USED AS AN ALTERNATIVE.

SECTION A-A'

A

A'

8'

6'

2'

3"

MIN

Flow

SEDIMENT SUMP DETAIL

NTS

STRAW OR HAY BALE DIKE DETAILS

NTS

NOTES:

1. BALES SHALL BE PLACED IN A ROW WITH ENDS TIGHTLY ABUTTING THE ADJACENT BALES.

2. ALL BALES SHALL BE EMBEDDED IN THE SOIL A MINIMUM OF FOUR (4) INCHES OR BALES COVERED WITH A FILTER MAT, WITH EARTH TAMPED

ON THE UPSTREAM SIDE TO PREVENT PIPING.

3. BALES SHALL BE SECURELY ANCHORED IN PLACE BY STAKES DRIVEN THROUGH THE BALES. THE FIRST STAKE IN EACH BALE SHALL BE

DRIVEN TOWARD PREVIOUSLY LAID BALE TO FORCE BALES TOGETHER.

4. BALES SHALL BE REMOVED AS DIRECTED BY THE ENGINEER.

ANCHORING DETAIL END VIEW

FLOW

EMBEDDED AS SITE

CONDITIONS DICTATE TO

PREVENT FLOW UNDER

BALES.

SOIL COMPACTED TO

PREVENT PIPING

ANGLE FIRST STAKE TOWARD

PREVIOUSLY LAID BALE

BOUND BALES

PLACED ON CONTOUR

2" X 2" STAKES MINIMUM OF 1 FT. INTO GROUND

SEDIMENT AND EROSION CONTROL

TOTAL

SHT. NO.

OFFICE OF SPECIAL RECLAMATION

SCALE: NTS

47 SCHOOL STREET, SUITE 301

PHILIPPI, WV 26416

OFFICE: 1-304-457-3219

FAX: 1-304-457-5613

Division of Land Restoration Office of Special Reclamation

West Virginia Department of Environmental Protection 05ENERGY MARKETING COMPANY INC.

PERMIT # U-72-83

BARBOUR COUNTY, WEST VIRGINIA 25DATE: SEPTEMBER 2023

4"

EXISTING CONDITIONS

TOTAL

SHT. NO.

OFFICE OF SPECIAL RECLAMATION

SCALE: NTS

47 SCHOOL STREET, SUITE 301

PHILIPPI, WV 26416

OFFICE: 1-304-457-3219

FAX: 1-304-457-5613

Division of Land Restoration Office of Special Reclamation

West Virginia Department of Environmental Protection

DATE: SEPTEMBER 2023

ENERGY MARKETING COMPANY INC.

11201130

1120 1090

24-INCH CULVERT

24-INCH CULVERT

24-INCH CULVERTS

24-INCH CULVERT

24-INCH CULVERT

18-INCH CULVERT

W

W

TREATMENT POND #1

(EXISTING)

TREATMENT POND #2 REMOVE

CULVERT

REMOVE

MANHOLES

& PIPE

POND

OUTLET

VAULT

MH 1

MH 2

MH 3

MH 4

BYPASS

MH TYPE 2

NOTE: SLOPE DITCH FROM POND DISCHARGE

TO ELEVATION OF 1156.00' TO ENTER VAULT.

FIELD ADJUST SIDE SLOPES OF DITCH TO

THE HEADWALL. DITCH TO BE GROUTED.

MH 5

HEADWALL

BYPASS MANHOLE

TYPE 1

TEMPORARY

OVERFLOW

DITCH

THE TEMPORARY OVERFLOW DITCH SHALL

BE FIELD ADJUST FROM BYPASS MH TYPE 1

TO THE GROUTED TRAPEZOIDAL DITCH

GROUT DITCH

RECLAIM

POND

HAYBALES

HAYBALES

HAYBALES

HAYBALES

HAYBALES

HAYBALES

HAYBALES

HAYBALES

SOUTH WETLAND

NORTH WETLAND

BONDED

AREA

BONDED

AREA

BONDED

AREA

BONDED

AREA

0 10 20 30 40 50 100

SCALE

DESIGN PLAN OVERVIEW

TOTAL

SHT. NO.

OFFICE OF SPECIAL RECLAMATION

SCALE: NTS

47 SCHOOL STREET, SUITE 301

PHILIPPI, WV 26416

OFFICE: 1-304-457-3219

FAX: 1-304-457-5613

Division of Land Restoration Office of Special Reclamation

West Virginia Department of Environmental Protection

DATE: SEPTEMBER 2023

ENERGY MARKETING COMPANY INC.

PERMIT # U-72-83

BARBOUR COUNTY, WEST VIRGINIA

AutoCAD SHX Text

18" DR17

AutoCAD SHX Text

18" INFLUENT

AutoCAD SHX Text

8" SDR35

AutoCAD SHX Text

8" SDR35

AutoCAD SHX Text

8" SDR35

AutoCAD SHX Text

8" SDR35

AutoCAD SHX Text

12" SDR35

AutoCAD SHX Text 1089.75

AutoCAD SHX Text 1090.75

AutoCAD SHX Text 1092.75

AutoCAD SHX Text 1092.75

AutoCAD SHX Text 1090.75

AutoCAD SHX Text 1090.75

AutoCAD SHX Text 1089.75

AutoCAD SHX Text 1089.75

AutoCAD SHX Text 1089.75

AutoCAD SHX Text 1092.75

AutoCAD SHX Text 1092.75

AutoCAD SHX Text 1092.75

AutoCAD SHX Text 1092.75

AutoCAD SHX Text 1090.75

AutoCAD SHX Text 1090.00

AutoCAD SHX Text 1090.00

AutoCAD SHX Text 1088.00

AutoCAD SHX Text 1092.00

AutoCAD SHX Text 1094.00

AutoCAD SHX Text 1096.00

AutoCAD SHX Text 1098.00

AutoCAD SHX Text 1100.00

AutoCAD SHX Text 1102.00

AutoCAD SHX Text 1104.00

AutoCAD SHX Text

12" SDR35

AutoCAD SHX Text 1092.75

AutoCAD SHX Text 1094.00

AutoCAD SHX Text 1096.00

AutoCAD SHX Text 1098.00

AutoCAD SHX Text 1100.00

AutoCAD SHX Text 1092.75

AutoCAD SHX Text 1088.00

AutoCAD SHX Text 1170.00

AutoCAD SHX Text 1168.00

AutoCAD SHX Text 1166.00

AutoCAD SHX Text 1164.00

AutoCAD SHX Text 1166.00

AutoCAD SHX Text 1164.00

AutoCAD SHX Text 1162.00

AutoCAD SHX Text 1162.00

AutoCAD SHX Text 1160.00

AutoCAD SHX Text 1130.00

AutoCAD SHX Text 1128.00

AutoCAD SHX Text 1126.00

AutoCAD SHX Text 1134.00

AutoCAD SHX Text 1136.00

AutoCAD SHX Text 1132.00

AutoCAD SHX Text 1158.00

AutoCAD SHX Text 1156.00

1154.00

24-INCH CULVERT

W

SOUTH WETLAND

223.33'

223.33'

NORTH WETLAND

6.

'99

.0 6'

6.

12'

12'

(EXISTING)

DI

ST

RI

BU

TI

ON

B

OX

DI

ST

RI

BU

TI

ON

B

OX

FL

OW

C

ON

TR

OL

B

OX

LEVEL CONTROL BOX

LEVEL CONTROL BOX

51.7'

6-FOOT SWALE

GROUTED TRAPEZOIDAL DITCH

REPLACE BOUNDARY FENCE.

REPLACE BOUNDARY FENCE.

L20 OUTLET

HAYBALESSTREAM BANKPROTECTIONR-24 RIPRAP

L20 OUTLET

ROAD

ROAD

ROAD

RO

AD

RO

AD

RO

AD

RO

AD

RO

AD

AC

CE

SS

R

OA

D

0 10 20 30 40 50 100

SCALE

GROUTED TRAPEZOIDAL DITCH

12'

CA

TC

H

BA

SI

N

CLEANOUT

CLEANOUT

CLEANOUT

CLEANOUT

12'

WETLAND PLAN VIEW

TOTAL

SHT. NO.

OFFICE OF SPECIAL RECLAMATION

SCALE: NTS

47 SCHOOL STREET, SUITE 301

PHILIPPI, WV 26416

OFFICE: 1-304-457-3219

FAX: 1-304-457-5613

Division of Land Restoration Office of Special Reclamation

West Virginia Department of Environmental Protection

DATE: SEPTEMBER 2023

ENERGY MARKETING COMPANY INC.

PERMIT # U-72-83

BARBOUR COUNTY, WEST VIRGINIA

AutoCAD SHX Text 1089.75

AutoCAD SHX Text 1090.75

AutoCAD SHX Text 1092.75

AutoCAD SHX Text 1092.75

AutoCAD SHX Text 1090.75

AutoCAD SHX Text 1090.75

AutoCAD SHX Text 1089.75

AutoCAD SHX Text 1089.75

AutoCAD SHX Text 1089.75

AutoCAD SHX Text 1092.75

AutoCAD SHX Text 1092.75

AutoCAD SHX Text 1092.75

AutoCAD SHX Text 1092.75

AutoCAD SHX Text 1090.75

AutoCAD SHX Text 1090.00

AutoCAD SHX Text 1090.00

AutoCAD SHX Text 1088.00

AutoCAD SHX Text 1092.00

AutoCAD SHX Text 1094.00

AutoCAD SHX Text 1096.00

AutoCAD SHX Text 1098.00

AutoCAD SHX Text 1092.75

AutoCAD SHX Text 1094.00

AutoCAD SHX Text 1096.00

AutoCAD SHX Text 1098.00

AutoCAD SHX Text 1100.00

AutoCAD SHX Text 1092.75

1088.00

601160

W

G

NA

TT

Y

CR

EE

K

MH 4

THE TEMPORARY OVERFLOW DITCH SHALL

BE FIELD ADJUST FROM BYPASS MH TYPE 1

TO THE GROUTED TRAPEZOIDAL DITCH

24-INCH CULVERT

(EXISTING)

18-INCH CULVERT

(EXISTING)

MH 3

MH 2

MH 1

MH 5

HEADWALL

BYPASS MH TYPE 2

GROUT DITCH

BYPASS MH TYPE 1

0 10 20 30 40 50 100

SCALE

24-INCH CULVERT

(EXISTING)

TREATMENT POND #1

(EXISTING)

TEMPORARY

OVERFLOW

DITCH

HAYBALES

HAYBALES

HAYBALES

HAYBALES

HAYBALES

COLLECTION LINE PLAN VIEW

TOTAL

SHT. NO.

OFFICE OF SPECIAL RECLAMATION

SCALE: NTS

47 SCHOOL STREET, SUITE 301

PHILIPPI, WV 26416

OFFICE: 1-304-457-3219

FAX: 1-304-457-5613

Division of Land Restoration Office of Special Reclamation

West Virginia Department of Environmental Protection

DATE: SEPTEMBER 2023

ENERGY MARKETING COMPANY INC.

PERMIT # U-72-83

BARBOUR COUNTY, WEST VIRGINIA

AutoCAD SHX Text 1100.00

AutoCAD SHX Text 1102.00

AutoCAD SHX Text 1104.00

AutoCAD SHX Text 1170.00

AutoCAD SHX Text 1168.00

AutoCAD SHX Text 1166.00

AutoCAD SHX Text 1164.00

AutoCAD SHX Text 1166.00

AutoCAD SHX Text 1164.00

AutoCAD SHX Text 1162.00

AutoCAD SHX Text 1162.00

1160.00

601160

1150 1160

-IN

CH

C

UL

VE

RT

24-INCH CULVERTS

TREATMENT POND #2

REMOVE

CULVERT

REMOVE

MANHOLES

& PIPE

NOTE: SLOPE DITCH FROM POND DISCHARGE

TO ELEVATION OF 1156.00' TO ENTER VAULT.

FIELD ADJUST SIDE SLOPES OF DITCH TO

THE HEADWALL. DITCH WILL BE GROUTED.

MH 3

MH 2

MH 1

MH 5

HEADWALL

BYPASS MH TYPE 2

POND OUTLET VAULT

0 10 20 30 40 50 100

SCALE

24-INCH CULVERT

(EXISTING)

TREATMENT POND #1

(EXISTING)

6-FOOT SWALE

(TO BE RECLAIMED)

HAYBALES

HAYBALES

HAYBALES

HAYBALES

TREATMENT POND RECLAMATION PLAN VIEW

TOTAL

SHT. NO.

OFFICE OF SPECIAL RECLAMATION

SCALE: NTS

47 SCHOOL STREET, SUITE 301

PHILIPPI, WV 26416

OFFICE: 1-304-457-3219

FAX: 1-304-457-5613

Division of Land Restoration Office of Special Reclamation

West Virginia Department of Environmental Protection

DATE: SEPTEMBER 2023

ENERGY MARKETING COMPANY INC.

PERMIT # U-72-83

BARBOUR COUNTY, WEST VIRGINIA

AutoCAD SHX Text 1170.00

AutoCAD SHX Text 1168.00

AutoCAD SHX Text 1166.00

AutoCAD SHX Text 1164.00

AutoCAD SHX Text 1166.00

AutoCAD SHX Text 1164.00

AutoCAD SHX Text 1162.00

AutoCAD SHX Text 1162.00

AutoCAD SHX Text 1160.00

AutoCAD SHX Text 1130.00

AutoCAD SHX Text 1128.00

AutoCAD SHX Text 1126.00

AutoCAD SHX Text 1134.00

AutoCAD SHX Text 1136.00

AutoCAD SHX Text 1132.00

AutoCAD SHX Text 1158.00

AutoCAD SHX Text 1156.00

1154.00

PROJECT DETAILS

TOTAL

SHT. NO.

OFFICE OF SPECIAL RECLAMATION

SCALE: NTS

47 SCHOOL STREET, SUITE 301

PHILIPPI, WV 26416

OFFICE: 1-304-457-3219

FAX: 1-304-457-5613

Division of Land Restoration Office of Special Reclamation

West Virginia Department of Environmental Protection

DATE: SEPTEMBER 2023

ENERGY MARKETING COMPANY INC.

PERMIT # U-72-83

BARBOUR COUNTY, WEST VIRGINIA

AutoCAD SHX Text

T.O.C. ELE. 1093.25ELE. 1093.25

AutoCAD SHX Text

T.O.G. ELE. 1092.75ELE. 1092.75

AutoCAD SHX Text

INF & EFF INV ELE. 1089.00

AutoCAD SHX Text

OVERFLOW INV ELE. 1091.25

AutoCAD SHX Text

BASE INV. ELE. 1086.25

AutoCAD SHX Text

AREA FILLED W/AGGREGATE

AutoCAD SHX Text

POND OUTLET VAULT

AutoCAD SHX Text

PROFILE VIEW

AutoCAD SHX Text

LEVEL CONTROL BOX

AutoCAD SHX Text

PLAN VIEW

AutoCAD SHX Text

VALVE WRENCH

AutoCAD SHX Text

10" SDR-35 INFLUENT

AutoCAD SHX Text

12" SDR-35 EFFLUENT

AutoCAD SHX Text 5'

AutoCAD SHX Text 7'

AutoCAD SHX Text

4'X4' GRATING

AutoCAD SHX Text

1.5'X2' GRATING

AutoCAD SHX Text

VALVE BOX LID

AutoCAD SHX Text

POND OUTLET VAULT

AutoCAD SHX Text

PLAN VIEW

AutoCAD SHX Text

FIBERGLASS GRATING, TYPICAL

AutoCAD SHX Text

FIBERGLASS GRATING, TYPICAL

AutoCAD SHX Text

T.O.C. ELE. 1060.50ELE. 1060.50

AutoCAD SHX Text

T.O.G. ELE. 1060.00ELE. 1060.00

AutoCAD SHX Text

18" SDR-35 EFFLUENT

AutoCAD SHX Text

2'X2' INLET

AutoCAD SHX Text

INV. ELE. 1155.50

AutoCAD SHX Text 5'

AutoCAD SHX Text 6'

AutoCAD SHX Text 8'

AutoCAD SHX Text

3'X3' GRATING

AutoCAD SHX Text

LEVEL CONTROL BOX

AutoCAD SHX Text

PROFILE VIEW

AutoCAD SHX Text

GO SEP GGV-R 24 X 24 GATE

AutoCAD SHX Text

HANDRAIL

AutoCAD SHX Text 12"X12"

OVERFLOW

PROJECTS DETAILS

TOTAL

SHT. NO.

OFFICE OF SPECIAL RECLAMATION

SCALE: NTS

47 SCHOOL STREET, SUITE 301

PHILIPPI, WV 26416

OFFICE: 1-304-457-3219

FAX: 1-304-457-5613

Division of Land Restoration Office of Special Reclamation

West Virginia Department of Environmental Protection

DATE: SEPTEMBER 2023

ENERGY MARKETING COMPANY INC.

PERMIT # U-72-83

BARBOUR COUNTY, WEST VIRGINIA

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

T.O.C. ELE. 1103.00ELE. 1103.00

AutoCAD SHX Text

T.O.G. ELE. 1102.50ELE. 1102.50

AutoCAD SHX Text

18" SDR-35 TEMPORARY OVERFLOW TO DITCH

AutoCAD SHX Text

INV ELE. 1100.00

AutoCAD SHX Text

INV ELE. 1096.48

AutoCAD SHX Text

NOTE: REFER TO PLAN VIEW FOR THE PROPER ORIENTATION OF THE PIPING.

AutoCAD SHX Text

18" SDR-35 TO FLOW CONTROL BOX

AutoCAD SHX Text

18" HDPE DR17

AutoCAD SHX Text

BYPASS MANHOLE TYPE 1

AutoCAD SHX Text

PROFILE VIEW

AutoCAD SHX Text

BYPASS MANHOLE TYPE 1

AutoCAD SHX Text

PLAN VIEW

AutoCAD SHX Text

18" HDPE DR17

AutoCAD SHX Text

18" SDR-35 TO FLOW CONTROL BOX

AutoCAD SHX Text

18" SDR-35 TEMPORARY OVERFLOW TO DITCH

AutoCAD SHX Text

5'DIA.

AutoCAD SHX Text

NOTE: PLACE GLUE CAP ON 18" SDR-35 TO FLOW CONTROL BOX.

AutoCAD SHX Text NOTE: ONCE VEGETATION TAKES ROOT AND GROWS TO AN AVERAGE OF 6", REMOVE CAP TO FLOW CONTROL BOX. CUT OVERFLOW PIPE OFF 1 FOOT OUTSIDE THE MANHOLE AND CAP BOTH ENDS OF OVERFLOW PIPE. RECLAIM OVER FLOW DITCH, SEED & MULCH.

AutoCAD SHX Text

NOTE: 3'X3' ALUMINUM HATCH. TO OPEN TOWARD THE CENTER OF MANHOLE.

AutoCAD SHX Text

BYPASS MANHOLE TYPE 1

AutoCAD SHX Text

PLAN VIEW

AutoCAD SHX Text

1. THE CONTRACTOR SHALL PROVIDE TEMPORARY ELECTRIC SERVICE FOR 6 MONTHS AFTER THE CONTRACTOR SHALL PROVIDE TEMPORARY ELECTRIC SERVICE FOR 6 MONTHS AFTER THE SEEDING OF THE WETLANDS, AND SHALL BE RESPONSIBLE FOR ALL ELECTRICAL CONNECTIONS FOR THE IRRIGATION SYSTEM. 2. THE VENDOR PROVIDING THE BYPASS MANHOLE TYPE 1 SHALL PROVIDE THE IRRIGATION PUMP, THE VENDOR PROVIDING THE BYPASS MANHOLE TYPE 1 SHALL PROVIDE THE IRRIGATION PUMP, PIPE CONNECTION TO OUTSIDE OF THE BYPASS MANHOLE, PUMP TIMER CONTROL, STANDARD IRRIGATION INDEXING VALVE, AND OSCILLATING SPRINKLERS. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PIPING, FITTINGS, AND CONNECTIONS THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PIPING, FITTINGS, AND CONNECTIONS FROM BYPASS MANHOLE TYPE 1 TO THE OSCILLATING SPRINKLERS.

AutoCAD SHX Text

IRRIGATION SYSTEM NOTES:

AutoCAD SHX Text

1. THE IRRIGATION PUMP SHALL BE INSTALLED FOUR (4) INCHED ABOVE THE THE IRRIGATION PUMP SHALL BE INSTALLED FOUR (4) INCHED ABOVE THE FLOOR BY PLACING A FOUR (4) INCH CINDER BLOCK UNDER THE PUMP. 2. THE PUMP PIPE CONNECTION SHALL BE A PITLESS ADAPTOR CONNECTION. THE PUMP PIPE CONNECTION SHALL BE A PITLESS ADAPTOR CONNECTION. 3. THE PIPE EXTENDING OUTSIDE THE MANHOLE SHALL BE ENLARGED TO TWO THE PIPE EXTENDING OUTSIDE THE MANHOLE SHALL BE ENLARGED TO TWO (2) INCH WITH A MALE CAMLOCK FITTING. A TWO (2) INCH CAMLOCK CAP SHALL BE PROVIDED. 4. THE IRRIGATION PUMP SHALL BE SINGLE PHASE 110V OR 220V AND RATED AT THE IRRIGATION PUMP SHALL BE SINGLE PHASE 110V OR 220V AND RATED AT 21 GPM @ 120 TDH.

IRRIGATION PUMP NOTES:

TOTAL

SHT. NO.

OFFICE OF SPECIAL RECLAMATION

SCALE: NTS

47 SCHOOL STREET, SUITE 301

PHILIPPI, WV 26416

OFFICE: 1-304-457-3219

FAX: 1-304-457-5613

Division of Land Restoration Office of Special Reclamation

West Virginia Department of Environmental Protection

DATE: SEPTEMBER 2023

ENERGY MARKETING COMPANY INC.

PERMIT # U-72-83

BARBOUR COUNTY, WEST VIRGINIA

AutoCAD SHX Text

T.O.C. ELE. 1166.50ELE. 1166.50

AutoCAD SHX Text

T.O.G. ELE. 1166.00ELE. 1166.00

AutoCAD SHX Text

T.O.C. ELE. 1164.00ELE. 1164.00

AutoCAD SHX Text

4'X4' GRATING

AutoCAD SHX Text

PROFILE VIEW

AutoCAD SHX Text

BYPASS MANHOLE TYPE 2

AutoCAD SHX Text

PROFILE VIEW

AutoCAD SHX Text

POND INFLUENT HEADWALL

AutoCAD SHX Text

18" SDR-35

AutoCAD SHX Text

18" SDR-35

AutoCAD SHX Text

18" SDR-35

AutoCAD SHX Text

18" SDR-35

AutoCAD SHX Text

POND INFLUENT HEADWALL

AutoCAD SHX Text

BYPASS MANHOLE TYPE 2

AutoCAD SHX Text

T.O.G. 2'X2' OPENING2'X2' OPENING

AutoCAD SHX Text

INV. ELE. 1162.00

AutoCAD SHX Text

18" SDR-35

AutoCAD SHX Text

GO SEP GHG-W-18 GATE, TYPICAL

AutoCAD SHX Text

FIBERGLASS GRATING

AutoCAD SHX Text NOTE: GO SEP GATES TO BE INSTALLED ON BOTH EFFLUENT PIPE. EACH GATE SHALL HAVE PIN TO LOCK THE GATE IN THE OPEN POSITION.

AutoCAD SHX Text

INV. ELE. 1162.00

AutoCAD SHX Text

PLAN VIEW

AutoCAD SHX Text

PLAN VIEW

AutoCAD SHX Text 7'

AutoCAD SHX Text 3'

AutoCAD SHX Text 2'

AutoCAD SHX Text 2'

AutoCAD SHX Text 5'

AutoCAD SHX Text

PROFILE VIEW (SOIL)

AutoCAD SHX Text

CONVEYANCE PIPE

AutoCAD SHX Text

LIME DUST OR ENGINEER APPROVED EQUAL

AutoCAD SHX Text

EXISITNG GRADE

AutoCAD SHX Text

0.6" MIN

AutoCAD SHX Text

2.0' MIN

AutoCAD SHX Text

1.0' MIN

AutoCAD SHX Text

1.0' MIN

AutoCAD SHX Text

SELECT BACKFILL

AutoCAD SHX Text

12" TOPSOIL

AutoCAD SHX Text

PROFILE VIEW (ROAD)

AutoCAD SHX Text

CONVEYANCE PIPE

AutoCAD SHX Text

LIME DUST OR ENGINEER APPROVED EQUAL

AutoCAD SHX Text

EXISITNG GRADE

AutoCAD SHX Text

0.6" MIN

AutoCAD SHX Text

2.0' MIN

AutoCAD SHX Text

1.0' MIN

AutoCAD SHX Text

1.0' MIN

1 " CRUSHER RUN 12" CRUSHER RUN AGGREGATE BACKFILL

TOTAL

SHT. NO.

OFFICE OF SPECIAL RECLAMATION

SCALE: NTS

47 SCHOOL STREET, SUITE 301

PHILIPPI, WV 26416

OFFICE: 1-304-457-3219

FAX: 1-304-457-5613

Division of Land Restoration Office of Special Reclamation

West Virginia Department of Environmental Protection

DATE: SEPTEMBER 2023

ENERGY MARKETING COMPANY INC.

PERMIT # U-72-83

BARBOUR COUNTY, WEST VIRGINIA

AutoCAD SHX Text

90 DEGREE HDPE ADJUSTABLE WEIR

AutoCAD SHX Text

PROFILE VIEW

AutoCAD SHX Text

DISTRIBUTION BOX

AutoCAD SHX Text

PROFILE VIEW

AutoCAD SHX Text

DISTRIBUTION BOX

AutoCAD SHX Text

PLAN VIEW

AutoCAD SHX Text

DISTRIBUTION BOX

AutoCAD SHX Text

12" SDR-35

AutoCAD SHX Text

8" SDR-35

AutoCAD SHX Text

8" SDR-35

AutoCAD SHX Text

8" SDR-35

AutoCAD SHX Text

8" SDR-35

AutoCAD SHX Text

8" SDR-35

AutoCAD SHX Text

12" SDR-35

AutoCAD SHX Text 4'

AutoCAD SHX Text 5'

AutoCAD SHX Text 3'

AutoCAD SHX Text 8'

AutoCAD SHX Text 7'

AutoCAD SHX Text 6'

AutoCAD SHX Text 22.8"

AutoCAD SHX Text 22.8"

AutoCAD SHX Text 1'

AutoCAD SHX Text 1.33'

AutoCAD SHX Text 1.33'

AutoCAD SHX Text 1.33'

AutoCAD SHX Text 1'

AutoCAD SHX Text

T.O.C. ELE. 1093.50ELE. 1093.50

AutoCAD SHX Text

INV. ELE. 1091.00

AutoCAD SHX Text

BASE ELE. 1190.50

AutoCAD SHX Text

GRATING

AutoCAD SHX Text

BAFFLE

AutoCAD SHX Text NOTE: THE VENDER SHALL PROVIDE THE ADJUSTABLE WEIR DETAILS IN THE SUBMITTAL PACKAGE. THE BAFFLE CAN BE STAINLESS STEEL OR HDPE. THE GRATING SHALL BE FIBERGLASS OR ALUMINUM. VERIFY INFLUENT LINE ORIENTATION BASED ON PROJECT PLANS.

T.O.C. ELE. 1093.00ELE. 1093.00

TOTAL

SHT. NO.

OFFICE OF SPECIAL RECLAMATION

SCALE: NTS

47 SCHOOL STREET, SUITE 301

PHILIPPI, WV 26416

OFFICE: 1-304-457-3219

FAX: 1-304-457-5613

Division of Land Restoration Office of Special Reclamation

West Virginia Department of Environmental Protection

DATE:SEPTEMBER 2023

ENERGY MARKETING COMPANY INC.

PERMIT # U-72-83

BARBOUR COUNTY, WEST VIRGINIA

AutoCAD SHX Text

MANHOLE #1

AutoCAD SHX Text

T.O.C. ELE. 1154.50ELE. 1154.50

AutoCAD SHX Text

T.O.G. ELE. 1154.00ELE. 1154.00

AutoCAD SHX Text

INV. ELE. 1149.50

AutoCAD SHX Text

MANHOLE #2

AutoCAD SHX Text

T.O.C. ELE. 1152.50ELE. 1152.50

AutoCAD SHX Text

T.O.G. ELE. 1152.00ELE. 1152.00

AutoCAD SHX Text

INV. ELE. 1047.50

AutoCAD SHX Text

MANHOLE #3

AutoCAD SHX Text

T.O.C. ELE. 1134.50ELE. 1134.50

AutoCAD SHX Text

T.O.G. ELE. 1134.00ELE. 1134.00

AutoCAD SHX Text

INV. ELE. 1129.50

AutoCAD SHX Text

MANHOLE #4

AutoCAD SHX Text

T.O.C. ELE. 1120.50ELE. 1120.50

AutoCAD SHX Text

T.O.G. ELE. 1120.00ELE. 1120.00

AutoCAD SHX Text

INV. ELE. 1115.50

AutoCAD SHX Text

MANHOLE #5

AutoCAD SHX Text

T.O.C. ELE. 1163.50ELE. 1163.50

AutoCAD SHX Text

T.O.G. ELE. 1163.00ELE. 1163.00

AutoCAD SHX Text

INV. ELE. 1158.50

AutoCAD SHX Text

18" SDR-35 TO MH #2

AutoCAD SHX Text

18" SDR-35 FROM POND OUTLET

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

18" SDR-35 FROM MH#1

AutoCAD SHX Text

18" SDR-35 FROM MH #6

AutoCAD SHX Text

18" SDR-35 TO MH #2

AutoCAD SHX Text

18" SDR-35 FROM MH#2

AutoCAD SHX Text

AutoCAD SHX Text

18" SDR-35 TO MH #4

AutoCAD SHX Text

PIPE BELL

AutoCAD SHX Text

18" SDR-35

AutoCAD SHX Text

PIPE BEDDING

AutoCAD SHX Text

4" WEEP HOLE

AutoCAD SHX Text

NATIVE SOIL

AutoCAD SHX Text

FINAL GRADE

AutoCAD SHX Text

2' MIN.

AutoCAD SHX Text

1.5' MIN.

AutoCAD SHX Text 1'

AutoCAD SHX Text NOTE: THE CONCRETE SHALL BE POURED AGAINST NATIVE SOIL WHERE SHOWN ON THE DETAILS.

AutoCAD SHX Text

PROFILE VIEW

AutoCAD SHX Text

CONCRETE PIPE ANCHOR

AutoCAD SHX Text

CONCRETE PIPE ANCHOR

AutoCAD SHX Text

PLAN VIEW

AutoCAD SHX Text

PIPE BELL

AutoCAD SHX Text

18" SDR-35

AutoCAD SHX Text

NATIVE SOIL

AutoCAD SHX Text

1.5' MIN.

AutoCAD SHX Text

1.5' MIN.

AutoCAD SHX Text

TRENCH WIDTH

AutoCAD SHX Text NOTE: INSTALL 6"X6" WIRE MESH WITH " OPENINGS ON 14" OPENINGS ON UPSTREAM SIDE OF WEEP HOLES.

AutoCAD SHX Text

4" WEEP HOLES

AutoCAD SHX Text

UNDISTIBURBED TRENCH WALL

AutoCAD SHX Text

NOTE: REMOVE FORMS PRIOR TO BACKFILLING TRENCH.

AutoCAD SHX Text

RESTEEL DETAIL

AutoCAD SHX Text

CONCRETE PIPE ANCHOR

AutoCAD SHX Text NOTE: TWO (2) LAYERS OF #4 RESTEEL. MAINTAIN A MINIMUM OF THREE (3) INCHES OF DISTANCE FROM CONCRETE SURFACE.

AutoCAD SHX Text

18" SDR-35 FROM MH#3

AutoCAD SHX Text

AutoCAD SHX Text

18" DR17 TO BYPASS MANHOLE TYPE 1

AutoCAD SHX Text

NOTE: ALL MANHOLES ARE 5' DIAMETER

AutoCAD SHX Text

18" SDR-35 TO MH #2

AutoCAD SHX Text

18" SDR-35 FROM BYPASS MANHOLE TYPE 2

TOTAL

SHT. NO.

OFFICE OF SPECIAL RECLAMATION

SCALE: NTS

47 SCHOOL STREET, SUITE 301

PHILIPPI, WV 26416

OFFICE: 1-304-457-3219

FAX: 1-304-457-5613

Division of Land Restoration Office of Special Reclamation

West Virginia Department of Environmental Protection

DATE: SEPTEMBER 2023

ENERGY MARKETING COMPANY INC.

PERMIT # U-72-83

BARBOUR COUNTY, WEST VIRGINIA

AutoCAD SHX Text 1089.00

AutoCAD SHX Text 1092.75

AutoCAD SHX Text

8-INCH SDR35

AutoCAD SHX Text

8-INCH SDR35 "T"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

10-INCH PERFORATED SDR35

AutoCAD SHX Text

SEE ROAD DETAIL

AutoCAD SHX Text

SEE ROAD DETAIL

AutoCAD SHX Text

1 FT X 3 FT 3-INCH

AutoCAD SHX Text

COMPACTED AGGREGATE

AutoCAD SHX Text

1 FT THICK 3-INCH

AutoCAD SHX Text

COMPACTED AGGREGATE

AutoCAD SHX Text 1089.75

AutoCAD SHX Text

WETLAND PROFILE

AutoCAD SHX Text

ADD 4-INCHES OF ORGANIC MATERIAL AND

AutoCAD SHX Text

TILL INTO THE SOIL PRIOR TO PLANTING.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

1" %%C HOLES,

AutoCAD SHX Text

TYPICAL

AutoCAD SHX Text 10"

AutoCAD SHX Text

DIA.

AutoCAD SHX Text

CROSS-SECTION

AutoCAD SHX Text

1 FOOT

AutoCAD SHX Text

TYPICAL

AutoCAD SHX Text

1 FOOT

AutoCAD SHX Text

TYPICAL

AutoCAD SHX Text

PROFILE

AutoCAD SHX Text

BERM

AutoCAD SHX Text

BERM

AutoCAD SHX Text

NOTE: ON THE WETLAND BERM, PLACE

AutoCAD SHX Text

R-3 AGGREGATE AND COMPACT WITH

AutoCAD SHX Text

EXCAVATOR BUCKET.

AutoCAD SHX Text

AREA 1

AutoCAD SHX Text

AREA 2

AutoCAD SHX Text

AREA 4

AutoCAD SHX Text

AREA 3

AutoCAD SHX Text

AREA 5

AutoCAD SHX Text

AREA 6

AutoCAD SHX Text

4400 FT

AutoCAD SHX Text

AutoCAD SHX Text

4400 FT

AutoCAD SHX Text

AutoCAD SHX Text

3700 FT

AutoCAD SHX Text

3700 FT

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

3700 FT

AutoCAD SHX Text

AutoCAD SHX Text

3700 FT

AutoCAD SHX Text

AutoCAD SHX Text

NORTH WETLAND

AutoCAD SHX Text

SOUTH WETLAND

AutoCAD SHX Text

WETLAND IRRIGATION

AutoCAD SHX Text

AREA 7

AutoCAD SHX Text

4400 FT

AutoCAD SHX Text

AutoCAD SHX Text

AREA 8

AutoCAD SHX Text

4100 FT

AutoCAD SHX Text

AutoCAD SHX Text

AREA 10

AutoCAD SHX Text

3700 FT

AutoCAD SHX Text

AutoCAD SHX Text

AREA 9

AutoCAD SHX Text

3700 FT

AutoCAD SHX Text

AutoCAD SHX Text

AREA 12

AutoCAD SHX Text

3700 FT

AutoCAD SHX Text

AutoCAD SHX Text

AREA 11

AutoCAD SHX Text

3700 FT

AutoCAD SHX Text

AutoCAD SHX Text 53'

AutoCAD SHX Text 53'

AutoCAD SHX Text 53'

AutoCAD SHX Text 53'

AutoCAD SHX Text 53'

AutoCAD SHX Text 53'

AutoCAD SHX Text 83'

AutoCAD SHX Text 70'

AutoCAD SHX Text 70'

AutoCAD SHX Text 70'

AutoCAD SHX Text 70'

AutoCAD SHX Text 83'

AutoCAD SHX Text 53'

AutoCAD SHX Text 53'

AutoCAD SHX Text 53'

AutoCAD SHX Text 53'

AutoCAD SHX Text 53'

AutoCAD SHX Text 50'

AutoCAD SHX Text

AQUA JOE SKU: 154643599

AutoCAD SHX Text

OSCILLATING SPRINKLER

AutoCAD SHX Text

TYPICAL

AutoCAD SHX Text

2-INCH LAYFLAT HOSE

AutoCAD SHX Text

2-INCH X 1-INCH "T"

AutoCAD SHX Text

W/ 5/8" WATER HOSE

AutoCAD SHX Text

INSERT, TYPICAL

AutoCAD SHX Text

5/8" WATER HOSE

AutoCAD SHX Text

NOTE: SYSTEM REQUIRES A 24 HOUR TIMER WITH 1 MINUTE ON/OFF INTERVALS.

AutoCAD SHX Text

NOTE: ALL EXPOSED (NOT BURIED)

AutoCAD SHX Text

PERMANENT PIPING SHALL BE PAINTED

AutoCAD SHX Text

WITH COAL TAR EPOXY.

AutoCAD SHX Text

EFFLUENT PIPE CLEANOUT AND ANCHOR

AutoCAD SHX Text 2'x2'x2' PRECAST CONCRETE BLOCK

AutoCAD SHX Text

1" STAINLESS STEEL STRAP

AutoCAD SHX Text

W/ 1/2" X 3" STAINLESS

AutoCAD SHX Text

CONCRETE ANCHOR.

AutoCAD SHX Text

SCREW ON CAP

AutoCAD SHX Text NOTE: PLACE TWO ANCHORS PER EFFLUENT LINE AT 25' & 50' FROM THE LEVEL CONTROL BOX.

AutoCAD SHX Text

PAINT EXPOSED PIPE

AutoCAD SHX Text FIMCO MANUFACTURING INC. MODEL # 92694 STANDARD FOUR ZONE INDEXING IRRIGATION VALVE. CONTRACTOR SHALL FIELD PLUMB THE VALVE TO THE LAY FLAT HOSE. THIS WILL REQUIRE REDUCER FITTINGS.

AutoCAD SHX Text

2-INCH LAYFLAT HOSE

FROM IRRIGATION PUMP

TOTAL

SHT. NO.

OFFICE OF SPECIAL RECLAMATION

SCALE: NTS

47 SCHOOL STREET, SUITE 301

PHILIPPI, WV 26416

OFFICE: 1-304-457-3219

FAX: 1-304-457-5613

Division of Land Restoration Office of Special Reclamation

West Virginia Department of Environmental Protection

DATE: SEPTEMBER 2023

ENERGY MARKETING COMPANY INC.

PERMIT # U-72-83

BARBOUR COUNTY, WEST VIRGINIA

AutoCAD SHX Text

GHG-W-12

AutoCAD SHX Text

45.8 LF OF 12-INCH SDR-35 @ 0.50%%%

AutoCAD SHX Text

DISTRIBUTION BOX

AutoCAD SHX Text

NORTH WETLAND

AutoCAD SHX Text

FLOW CONTROL BOX

AutoCAD SHX Text

DISTRIBUTION BOX

AutoCAD SHX Text

SOUTH WETLAND

AutoCAD SHX Text

INV. 1091.25'

AutoCAD SHX Text

TOG 1095.77'

AutoCAD SHX Text

TOC 1096.77'

AutoCAD SHX Text

72.5 LF OF 12-INCH SDR-35 @ 0.34%%%

AutoCAD SHX Text

INV. 1091.25'

AutoCAD SHX Text

INV. 1091.00'

AutoCAD SHX Text

TOG 1092.75'

AutoCAD SHX Text

FLOW CONTROL BOX

AutoCAD SHX Text

PLAN VIEW

AutoCAD SHX Text

FLOW CONTROL BOX

AutoCAD SHX Text

PROFILE VIEW C-C'

AutoCAD SHX Text C

AutoCAD SHX Text C'

AutoCAD SHX Text B

AutoCAD SHX Text B'

AutoCAD SHX Text A

AutoCAD SHX Text A'

AutoCAD SHX Text

FLOW CONTROL BOX

AutoCAD SHX Text

PROFILE VIEW B-B'

AutoCAD SHX Text

FLOW CONTROL BOX

AutoCAD SHX Text

PROFILE VIEW A-A'

AutoCAD SHX Text 5'

AutoCAD SHX Text 6'

AutoCAD SHX Text 4'

AutoCAD SHX Text 4'

AutoCAD SHX Text 5'

AutoCAD SHX Text 6'

AutoCAD SHX Text

GO SEP GATE GHG-W-12

AutoCAD SHX Text 12"

AutoCAD SHX Text

SDR-35

AutoCAD SHX Text 12"

AutoCAD SHX Text

SDR-35

AutoCAD SHX Text 12"

AutoCAD SHX Text

SDR-35

AutoCAD SHX Text 12"

AutoCAD SHX Text

SDR-35

AutoCAD SHX Text 18"

AutoCAD SHX Text

SDR-35

AutoCAD SHX Text

ALUMINUM HATCH 4'X4'

AutoCAD SHX Text

GRATING

AutoCAD SHX Text

BAFFLE

AutoCAD SHX Text

WEIR

AutoCAD SHX Text

TOB 1090.75'

AutoCAD SHX Text

INV 1091.25'

AutoCAD SHX Text

GRT 1092.75'

AutoCAD SHX Text

TOG 1095.77'

AutoCAD SHX Text

TOC 1096.77'

AutoCAD SHX Text

BOB 1091.25'

AutoCAD SHX Text

TOB 1090.00'

AutoCAD SHX Text NOTE: GO SEP GATES TO BE INSTALLED ON BOTH EFFLUENT PIPES. EACH GATE SHALL HAVE PIN TO LOCK THE GATE IN THE OPEN POSITION.

AutoCAD SHX Text NOTE: THE VENDER SHALL PROVIDE THE ADJUSTABLE WEIR DETAILS IN THE SUBMITTAL PACKAGE. THE BAFFLE CAN BE STAINLESS STEEL OR HDPE. THE GRATING SHALL BE FIBERGLASS OR ALUMINUM.

AutoCAD SHX Text

INV. 1091.00'

AutoCAD SHX Text

TOG 1092.75'

NOTE: FIELD ADJUST BACKFILL AROUND FLOW CONTROL BOX AS ON DETAIL. NOT SHOWN ON PLAN VIEW.

PIPE PROFILES

TOTAL

SHT. NO.

OFFICE OF SPECIAL RECLAMATION

SCALE: NTS

47 SCHOOL STREET, SUITE 301

PHILIPPI, WV 26416

OFFICE: 1-304-457-3219

FAX: 1-304-457-5613

Division of Land Restoration Office of Special Reclamation

West Virginia Department of Environmental Protection

DATE: SEPTEMBER 2023

ENERGY MARKETING COMPANY INC.

PERMIT # U-72-83

BARBOUR COUNTY, WEST VIRGINIA

AutoCAD SHX Text

POND OUTLET VAULT TO MANHOLE #1 TO MANHOLE #2

AutoCAD SHX Text

BYPASS MANHOLE TYPE 2 TO MANHOLE #5 TO MANHOLE #2

AutoCAD SHX Text 0+00

AutoCAD SHX Text 0+20

AutoCAD SHX Text 0+40

AutoCAD SHX Text 0+60

AutoCAD SHX Text 0+80

AutoCAD SHX Text 1+00

AutoCAD SHX Text 1+20

AutoCAD SHX Text 1+40

AutoCAD SHX Text 0+48.73

AutoCAD SHX Text

BYPASS MH TYPE 2

AutoCAD SHX Text

48.77-LF @ 7.55%%% OF 18-INCH SDR35

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 0+00

AutoCAD SHX Text 0+20

AutoCAD SHX Text 0+40

AutoCAD SHX Text 0+60

AutoCAD SHX Text 0+80

AutoCAD SHX Text 1+00

AutoCAD SHX Text 1+20

AutoCAD SHX Text 1+40

AutoCAD SHX Text 0+63.16

AutoCAD SHX Text

POND OUTLET

AutoCAD SHX Text

63.46-LF @ 10.29%%% OF 18-INCH SDR35

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

MH #1

AutoCAD…

This is the start of the file's text. The full file is on GovTribe.