Endo Concept 090823.pdf
PDF 283 KB Posted
- Solicitation number
- 36C25924R0019
About this file
This document contains an architectural floor plan and details for renovating the third floor of the Cowboy building at a Department of Veterans Affairs medical center, along with the associated federal contract opportunity. The floor plan drawing depicts the existing layout and calls for modifications including reconfiguring a patient recovery bay to be 10 feet by 10 feet to accommodate four such bays. It also indicates installing a modular nurse station and a reception area with small workspaces for three staff including two transaction windows, one of which must be ADA compliant. The related federal contract opportunity is solicitation number 36C25924R0019 to renovate the third floor Cowboy area and other locations. It was issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 19. No response or award dates were provided.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25924R0019 0001.docx | DOCX document | |
| DB Construction Experience Sheet corrected.docx | DOCX document | |
| S02 Past Performance Questionnaire.docx | DOCX document | |
| 36C25924R0019.docx | DOCX document | |
| S22 LOS 852.219-75.docx | DOCX document | |
| Existing Med Gas Schedule 3rd Floor Cowboy 092523.pdf | ||
| DB Construction Experience Sheet.docx | DOCX document | |
| HRB10 Series Handrail Crashrail Bumper.pdf | ||
| Wage Determination WY20230023 4 7 2023.pdf | ||
| Corr finish ref pic.jpg | JPG image |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SCALE: 116" = 1'-0"
0 4'-0" 8'-0" 16'-0"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
Revisions: Date:
G
H
Local I.D.AS-BUILT BY:
Project Director
(EAST) COWBOY AS-BUILT
EMS / ENDO
FLOOR PLAN
THIRD FLOOR
4/3/23 - DJM
1-A
ARCHITECTURAL
A-304
RE
MA
TC
HL
IN
E A-
AutoCAD SHX Text THIS DRAWING MAY OR MAY NOT REFLECT ACTUAL LAYOUT OF THE SYSTEMS SHOWN. FIELD VERIFY EXACT INSTALLATION PRIOR TO ANY MODIFICATION. THIS DRAWING IS FOR SUPPLEMENTAL INFORMATION ONLY.
AutoCAD SHX Text
LOCATION
../PDF/Overall plan.pdf AutoCAD SHX Text C3-92B
AutoCAD SHX Text
TOILET
AutoCAD SHX Text
AutoCAD SHX Text C3-92
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text C3-95
AutoCAD SHX Text C3-91
AutoCAD SHX Text
PATIENT
AutoCAD SHX Text
RECOVERY
AutoCAD SHX Text
AutoCAD SHX Text C3-90
AutoCAD SHX Text
TOILET
AutoCAD SHX Text C3-93
AutoCAD SHX Text C3-88
AutoCAD SHX Text
CHECK IN
AutoCAD SHX Text
AutoCAD SHX Text C3-89
AutoCAD SHX Text
HAC
AutoCAD SHX Text C3-91
AutoCAD SHX Text C3-95
AutoCAD SHX Text
OXYGEN/
AutoCAD SHX Text
SPD STORAGE
AutoCAD SHX Text C3-92
AutoCAD SHX Text C3-87
AutoCAD SHX Text
SOILED UTILITY
AutoCAD SHX Text
AutoCAD SHX Text C3-86
AutoCAD SHX Text
ENDO 1
AutoCAD SHX Text
AutoCAD SHX Text C3-85
AutoCAD SHX Text
CLEAN UTILITY
AutoCAD SHX Text
AutoCAD SHX Text C3-84
AutoCAD SHX Text
SCOPE
AutoCAD SHX Text
AutoCAD SHX Text C3-76
AutoCAD SHX Text
EMS LINEN ROOM
AutoCAD SHX Text C3-110
AutoCAD SHX Text C3-75
AutoCAD SHX Text
GENERAL STORAGE
AutoCAD SHX Text C3-104
AutoCAD SHX Text C3-74
AutoCAD SHX Text
EMS
AutoCAD SHX Text
TRAINING
AutoCAD SHX Text C3-107
AutoCAD SHX Text C3-73A
AutoCAD SHX Text
EMS CONFERENCE
AutoCAD SHX Text C3-100A
AutoCAD SHX Text C3-73
AutoCAD SHX Text
EMS KITCHEN
AutoCAD SHX Text C3-100
AutoCAD SHX Text C3-72B
AutoCAD SHX Text
EMS
AutoCAD SHX Text
SUPERVISOR
AutoCAD SHX Text C3-105B
AutoCAD SHX Text C3-72A
AutoCAD SHX Text
VISN STAFF
AutoCAD SHX Text C3-105A
AutoCAD SHX Text C3-72
AutoCAD SHX Text
EMS
AutoCAD SHX Text C3-105
AutoCAD SHX Text C3-82
AutoCAD SHX Text
ENDO 2
AutoCAD SHX Text
AutoCAD SHX Text C3-70
AutoCAD SHX Text
WAITING ROOM
AutoCAD SHX Text C3-83
AutoCAD SHX Text C3-68
AutoCAD SHX Text
PHARMACY
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text C3-81
AutoCAD SHX Text C3-66
AutoCAD SHX Text
CFED SIM MAN
AutoCAD SHX Text
TRAINING ROOM
AutoCAD SHX Text
AutoCAD SHX Text C3-05C
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
AutoCAD SHX Text C3-04C
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
AutoCAD SHX Text C3-01C
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
AutoCAD SHX Text S9F3
AutoCAD SHX Text
TO "A" ATTIC
AutoCAD SHX Text
STAIRS
AutoCAD SHX Text
AutoCAD SHX Text C2-3
AutoCAD SHX Text
ELEVATOR
AutoCAD SHX Text
AutoCAD SHX Text C1-3
AutoCAD SHX Text
ELEVATOR
AutoCAD SHX Text
AutoCAD SHX Text C3-73B
AutoCAD SHX Text
IT
AutoCAD SHX Text
AutoCAD SHX Text
MECH CHASE
AutoCAD SHX Text C3-69
AutoCAD SHX Text
NURSE OFFICE
AutoCAD SHX Text
AutoCAD SHX Text C3-S04
AutoCAD SHX Text
ATTIC SPACE
AutoCAD SHX Text
HALF FLR HIGHER
AutoCAD SHX Text
SIGN MISSING
AutoCAD SHX Text C3-S03
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
AutoCAD SHX Text C3-02C
AutoCAD SHX Text
LOBBY
AutoCAD SHX Text
AutoCAD SHX Text C3-S02
AutoCAD SHX Text C3-S01
AutoCAD SHX Text
ATTIC
AutoCAD SHX Text
AutoCAD SHX Text
EMPTY RM
AutoCAD SHX Text
HALF FLR
AutoCAD SHX Text
LOWER
AutoCAD SHX Text
AutoCAD SHX Text
ELEV. RM
AutoCAD SHX Text
HALF FLR
AutoCAD SHX Text
HIGHER
AutoCAD SHX Text
AutoCAD SHX Text
MECH
AutoCAD SHX Text
ON CURRENT
AutoCAD SHX Text
3RD FLR LEVEL
AutoCAD SHX Text
AutoCAD SHX Text
DN
AutoCAD SHX Text
UP
../PDF/Overall plan.pdf ../PDF/Overall plan.pdf ../PDF/Overall plan.pdf ../PDF/Overall plan.pdf ../PDF/Overall plan.pdf ../PDF/Overall plan.pdf ../PDF/Overall plan.pdf ../PDF/Overall plan.pdf ../PDF/Overall plan.pdf ../PDF/Overall plan.pdf ../PDF/Overall plan.pdf ../PDF/Overall plan.pdf ../PDF/Overall plan.pdf ../PDF/Overall plan.pdf ../PDF/Overall plan.pdf ../PDF/Overall plan.pdf ../PDF/Overall plan.pdf ../PDF/Overall plan.pdf ../PDF/Overall plan.pdf AutoCAD SHX Text
%%UAHU-19
AutoCAD SHX Text
%%URTU-17
AutoCAD SHX Text
%%UMAU-17
TJ Hopkins Line
TJ Hopkins Line
TJ Hopkins Arrow
TJ Hopkins Callout Reconfigure this bay so the footprint is 10' x 10' to comply with design requirement resulting in a total of (4) 10' X 10' patient recovery bays
TJ Hopkins Text Box
TJ Hopkins Text Box
TJ Hopkins Text Box
TJ Hopkins Callout Modular RN station solution
TJ Hopkins Text Box
TJ Hopkins Text Box
TJ Hopkins Line
TJ Hopkins Callout Reception for Admin and small work area for a total of (3) staff, (2) transaction window (1) must be ADA compliant
TJ Hopkins Line
TJ Hopkins Line
TJ Hopkins Snapshot
TJ Hopkins Text Box
TJ Hopkins Ellipse
TJ Hopkins Ellipse
TJ Hopkins Ellipse
TJ Hopkins Ellipse
TJ Hopkins Arrow
TJ Hopkins Rectangle Sketch to Scale
6.4 sf
TJ Hopkins Rectangle Sketch to Scale
6.4 sf
TJ Hopkins Rectangle Sketch to Scale
6.4 sf
TJ Hopkins Rectangle Sketch to Scale
9.6 sf
TJ Hopkins Rectangle Sketch to Scale
9.6 sf
TJ Hopkins Rectangle Sketch to Scale
9.6 sf
TJ Hopkins Ellipse
TJ Hopkins Ellipse
TJ Hopkins Ellipse
TJ Hopkins Rectangle Sketch to Scale
2.78 sf
TJ Hopkins Rectangle Sketch to Scale
2.78 sf
TJ Hopkins Rectangle Sketch to Scale
2.78 sf
TJ Hopkins Rectangle Sketch to Scale
2.78 sf
TJ Hopkins Rectangle Sketch to Scale
2.78 sf
TJ Hopkins Rectangle Sketch to Scale
2.78 sf
TJ Hopkins Rectangle Sketch to Scale
2.78 sf
TJ Hopkins Rectangle Sketch to Scale
2.78 sf
TJ Hopkins Rectangle Sketch to Scale
2.78 sf
TJ Hopkins Rectangle Sketch to Scale
2.78 sf
TJ Hopkins Rectangle Sketch to Scale
2.78 sf
TJ Hopkins Rectangle Sketch to Scale
2.78 sf
File details come from the government source that posted it. Updated .