Enclosure 1 Unit Addresses.docx

DOCX document 19 KB Posted

Attached to
FIRE ALARM & SUB SYSTEMS TESTING/INSPECTION
Solicitation number
37050PR250000005
Issued by

About this file

This document is an enclosure listing detailed information about fire safety systems at nine U.S. Coast Guard facilities across Pennsylvania, New Jersey, and Delaware. The document provides specific location addresses, points of contact, and comprehensive technical details for fire panels, suppression systems, and sprinkler systems at each facility. Key locations include USCG Sector Delaware Bay (Philadelphia), Stations Atlantic City, Great Egg, Manasquan, Barnegat Light, Townsend Inlet, Fortescue, Indian River, and MSD Lewes.

Each facility's entry details the specific fire panel models installed (including manufacturers like Fire-Lite, ADT, Pro-Tec, EST, Faraday, Honeywell, and Simplex Grinnell), along with exact counts of audio visual alarms, pull stations, smoke detectors, CO detectors, and sprinkler heads. Where applicable, Gaylord hood systems are specified with tank models (Range Guard and Kidde), and water sprinkler systems are described with their components including Leslie valves, back pressure valves, and cutoff valves. This technical inventory appears to support the related contract opportunity for fire alarm and suppression system testing and inspection services across these facilities.

View the file

Other files

File Type Posted
SF1449 37050PR250000005.pdf PDF
SF1449 37050PR250000005.pdf PDF
Delaware 15-4217.txt TXT text file
Cape May County 15-4197.txt TXT text file
PA 15-4233.txt TXT text file
ALARM MONITORING SYSTEM INSPECTION PWS.docx DOCX document
SF1449 37050PR250000005.pdf PDF
Enclosure 2.pdf PDF
Enclosure 4.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

USCG Sector Delaware Bay 1 Washington Ave Philadelphia, PA 19147 POC: DCC Sean McGinty Phone: 757-638-5981

FIRE PANEL: System 2 universal alarm control. Model No: Cp-35 control unit, 66 audio visual alarms, 33 pull stations, 81 photoelectric smoke detectors, 3 duct smoke detectors, 95 smoke detectors

GAYLORD HOOD SYSTEM: Range Guard Tank model RG-2.5G FIRE & SPRINKLER SYSTEM: Water supplied by city has Leslie valve, 2 back pressure valves, 3 cut off valves and 2 hose connections.

USCG Station Atlantic City 900 Beach Thorofare Atlantic City, NJ 08401 POC: MKC Jon Christiansen Phone: 732-300-1060

Station Bldg: Fire Panel: Fire-Lite MS-9600UDLS, 15 audio visual alarms, 14 pull stations, 50 heat detectors, & 3 CO Detectors.

UPH Bldg: Fire Panel: Fire-Lite MS-5UD, 8 audio visual alarms, 2 pull stations, 24 photoelectric smoke detectors, 18 CO Photoelectric smoke detectors, 56 sprinklers.

GAYLORD HOOD SYSTEM: Range Guard Tank Model RG-2.5G FIRE & WATER SPRINKLER SYSTEM: Water supplied by city has Leslie valve, 2 back pressure values, 3 cut off values, 3 check valves, 2 hose connections.

USCG Station Great Egg 101 Northpoint Blvd.

Ocean City, NJ 08226 POC: MKC Jon Christiansen Phone: 732-300-1060

FIRE PANEL: ADT Unimode 5, 6 audio visual alarms, 9 pull stations, 29 photoelectric smoke detectors, 5 smoke detectors, 2 bell alarms.

USCG Station Manasquan 61 Inlet Drive Point Pleasant Beach, NJ 08006 POC: MKC Thomas Goan Phone: 609-304-3072

Station Bldg: Fire Panel: Pro-Tec Systems MPC-6000, 4 audio visual alarms, 6 pull stations, 45 smoke detectors, 3 photoelectric smoke detectors.

GAYLORD HOOD SYSTEM: Kidde Tank Model WHDR-400M BOAT HOUSE: Fire Panel: EST i0500 Intelligent Life Safety System, 50 audio visual alarms, 12 pull stations, 79 photoelectric smoke detectors, 9 photoelectric smoke/CO detectors, 193 sprinklers FIRE & WATER SPRINKLER SYSTEM: Water supplied by city has Leslie valve, 2 back pressure values, 3 cut off values, 3 check valves, 2 hose connections.

USCG Station Barnegat Light 601 Bayview Ave Barnegat Light, NJ 08006 POC: MKC Lantz Fortner Phone: 732-674-0598

Station Bldg: Fire Panel: Faraday MPC-6000, 5 audio visual alarms, 9 pull stations, 25 photoelectric smoke detectors, 5 CO/ photoelectric smoke detectors, 4 fire plugs GAYLORD HOOD SYSTEM: Kidde Tank System Tank Model WHDR-400M BOAT HOUSE: Fire Panel: Faraday MPC-6000, 4 audio visual alarms, 4 pull stations, 12 photoelectric smoke detectors, 2 CO / photoelectric smoke detectors

USCG Station Townsend Inlet 233 82nd Street Sea Isle City, NJ 08234 POC: MKC Joshua Pearson Phone: 716-870-0080

FIRE PANEL: Honeywell Ademco Vista-32FB, 6 audio visual alarms, 6 pull stations, 14 photoelectric smoke detectors.

USCG Station Fortescue 45 Creek Ave Millville, NJ 08332 POC: MKC Joshua Pearson Phone: 716-870-0080

FIRE PANEL: General Electric EST i0500 (G/R)(D) FIRE PUMP CONTROLLER: Metron Eledyne Model MP30-7.5-240B, 5 audio visual alarms, 4 pull stations, 12 photoelectric smoke detectors, 22 sprinklers.

FIRE & WATER SPRINKLER SYSTEM: Water supplied by reservoir with fire pumpl, 1 Leslie valve, 2 cutout valves, 4 bleed valves.

USCG Station Indian River 39373 Inlet Rd.

Rehoboth Beach, DE 19971 POC: MK1 Patrick Chemodurow Phone: 302-227-2440

FIRE PANEL: Simplex Grinnell AUTOCALL TFX-400, 15 audio visual alarms, 15 pull stations, 10 heat detectors, 30 smoke detectors, 5 horns, 1 bell, Captive Aire Core Fire Protection System

MSD Lewes 802 Pilottown Road Lewes, DE 19958 POC: MSTC Terry Clark Phone: 302-644-1909

FIRE PANEL: Honeywell Vista-128FBP, 2 audio visual alarms, 6 pull stations, 10 photoelectric smoke detectors, 3 CO/ photoelectric smoke detectors.

Enclosure (2)