The document provided is a set of Salient Characteristics for an Enclosed Utility Bumper Pull Trailer that will be used to transport equipment, provide personnel shelter, and serve as a staging area during hazardous material spill response operations at the Neuse River adjacent to Seymour Johnson Air Force Base.
The key requirements include: 18-22 foot length, 16,000 lbs GVWR with dual 8,000 lbs torsion axles, electric brakes, 16-inch steel wheels, 4-point automatic leveling system, rivetless aluminum construction, curbside entry, and fold-down rear cargo door/ramp. The trailer must also include scene lighting, a light tower, 16-inch awning, interior LED lighting, large and small item storage, a residential refrigerator, dual 12V deep cycle batteries, an 8kW diesel generator, at least 8 interior and 6 exterior AC outlets, two 16,000 BTU HVAC units, and an automation system to control all subsystems. The trailer must have a minimum 12-year structural/construction warranty.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SALIENT CHARACTERISTICS – ENCLOSED TRAILER
A. DESCRIPTION: This requirement is for an enclosed utility bumper pull trailer for equipment transport that shall be used to transport equipment, provide personnel shelter, and serve as staging area during hazardous material spill response operations at the Neuse River, adjacent to Seymour Johnson Air Force Base. The trailer shall also serve as shelter for five (5) to six (6) personnel during operational use.
B. REQUIREMENT:
1. Bumper Pull Trailer:
a. Eighteen (18) to 22 feet in length.
b. Engineered, manufactured, and certified to applicable NATM, RVIA, NFPA, OSHA, FVMSS and Mil-STD guidelines.
c. Minimum of 16,000-pound gross vehicle weight rating (GVWR) with two (2) 8,000-pound torsion axles.
d. Electric brakes with break-away kit and gel-cell battery.
e. Minimum of 16-inch steel wheels.
f. Four (4) point automatic electric leveling system.
g. Rivetless aluminum construction, minimum of .090-inch-thick aluminum sheet.
h. Curbside entry door.
i. Fold-down rear cargo door/ramp the width and height of the rear of the trailer.
2. Shelter Exterior:
a. DOT lighting to meet or exceed FMVSS 108.
b. Scene lighting, white LED lighting for perimeter of trailer.
c. Light tower with position control.
d. Minimum 16-inch awning mounted on the curbside.
3. Shelter Interior:
a. Interior lighting -- low-profile surface mount LED.
b. Large item tool storage -- roll-up doors for full access
i. Thirty-six (36) to 48 inches wide
ii. Sixty (60) to 72 inches in height
c. Small item tool storage -- mounted tool chest
i. Counter top height and 36 to 48 inches wide
d. Additional storage -- optimized cabinet space.
e. A full-sized residential refrigerator that shall be used for storing for fuel samples.
4. Electrical Distribution:
a. Minimum of two (2) Group-31 12-vault, deep cycle, lead acid auxiliary batteries.
b. Minimum eight (8) kilowatt (kW) diesel generator.
c. Onboard fuel tank, for minimum 48-hour continuous runtime
d. Interior, minimum of eight (8) interior and six (6) exterior AC power outlets.
e. All electrical circuits and appliances shall be UL listed and conform to applicable national electric codes, NEC, and FMVSS regulations.
f. The AC power distribution panel shall be installed and equipped with single-phase, three-wire service and be configured with thermal magnetic circuit breakers sized for 125% of the anticipated load.
5. Heating Ventilation and Air Conditioning (HVAC): Minimum of two (2) 16,000 BTU rooftop mounted HVAC units.
6. Asset Control System:
a. Trailer shall have an automation system for controlling all subsystems from a single interface.
b. Leveling legs, generator, light tower, HVAC, etc., shall all be accessible through a mounted tablet.
c. Software must be NIST 800-171 compliant for access-control, logging, identification, authentication, etc. Must meet STIG requirements.
C. WARRANTY
Must have a minimum 12 years structural/construction warranty, to include material and workmanship.
ACRONYMS:
DOT - Department of Transportation FVMSS - Federal Motor Vehicle Safety Standards Mil-STD - Military Standard NATM - National Association of Trailer Manufacturers NEC - National Electrical Code NFPA - National Fire Protection Association NIST - National Institute of Standards and Technology OSHA - Occupational Safety and Health Administration RVIA - Recreational Vehicle Industry Association STIG - Security Technical Implementation Guide UL - Underwriters Laboratories