This is an electrical design drawing document prepared for Stilley Station, a waste management facility located in Beaufort County, North Carolina. The project involves the installation of a comprehensive electrical system including site lighting, multiple electrical panels (Panels A, B, and C), grounding systems, and distribution infrastructure to support various operational equipment including compactors, a multi-material processor, and facility buildings. The electrical system is designed for 120/208V three-phase service with a 600-amp main service panel rated at 92 amps continuous load. The drawings specify LED lighting fixtures from Lithonia, including roadway-type fixtures and exterior canopy lights mounted on 40-foot wood poles, with approximately 26 total pole-mounted fixtures distributed across the site. The design accommodates multiple 15HP and 30HP compactor motors, HVAC systems, receptacles, and emergency lighting throughout the facility.
The electrical installation must comply with the 2020 National Electrical Code (NEC) and includes detailed specifications for conduit sizing (ranging from 1/2-inch to 3-inch PVC and rigid steel), wire gauges (#12 through #500 AWG copper conductors), grounding electrodes consisting of three 3/4-inch by 10-foot ground rods, and comprehensive bonding requirements. The contractor is responsible for all labor, materials, coordination with other trades, utility location, and compliance with manufacturer specifications. Panel schedules indicate load calculations totaling 144.6 kVA demand, with dedicated circuits for specific equipment loads. The design includes provisions for future expansion with spare circuits and conduit runs, along with photocell-controlled lighting and multiple GFI-protected receptacles in wet locations. Documentation requirements include shop drawing submittals, panel schedules with load descriptions, operating and maintenance manuals, one-year warranty on all materials and installation, and coordination with the utility company for service connection and any owner-furnished equipment.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
E2
E2
YARD WASTE
PAD
CUSTOMER
UNLOADING
AREA
3/31/26
SCALE: N1 ELECTRICAL SITE LIGHTING PLAN
1" = 75'-0"
LIGHTING NOTES:
LIGHT FIXTURE SCHEDULE
INSTALLATION KEYED NOTES " # ":
E1
EL
EC
TR
IC
AL
S
IT
E
PL
AN
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text A-6,8
AutoCAD SHX Text B
AutoCAD SHX Text
#8AWG
AutoCAD SHX Text A-10,12
AutoCAD SHX Text
#6AWG
AutoCAD SHX Text
#8AWG
AutoCAD SHX Text
#8AWG
AutoCAD SHX Text
#8AWG
AutoCAD SHX Text
#6AWG
AutoCAD SHX Text
#10AWG
AutoCAD SHX Text
#8AWG
AutoCAD SHX Text
#8AWG
AutoCAD SHX Text B
AutoCAD SHX Text A-6,8
AutoCAD SHX Text
#8AWG
AutoCAD SHX Text
#8AWG
AutoCAD SHX Text
#10AWG
AutoCAD SHX Text
#10AWG
AutoCAD SHX Text
PANEL "C"
AutoCAD SHX Text
AutoCAD SHX Text
#10AWG
AutoCAD SHX Text
#8AWG
AutoCAD SHX Text A-2,4
AutoCAD SHX Text
#8AWG
AutoCAD SHX Text
PANEL "A"
AutoCAD SHX Text
REV.
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
CLIENT DWG. NO.
AutoCAD SHX Text
OF
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
PROJECT/LOCATION
AutoCAD SHX Text
PROJECT NO.
AutoCAD SHX Text
APPROVED BY
AutoCAD SHX Text
CHECKED BY
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
PROJECT MGR.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
(919) 778-9064
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
REV.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
P.O. BOX 11527
AutoCAD SHX Text
BY
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
GOLDSBORO, NC 27532
AutoCAD SHX Text
TEL:
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
BEAUFORT COUNTY
AutoCAD SHX Text
PROJNO
AutoCAD SHX Text
JDH
AutoCAD SHX Text
STILLEY STATION
AutoCAD SHX Text
NC LIC #: C-1132
AutoCAD SHX Text N/A
AutoCAD SHX Text
BLT
AutoCAD SHX Text
JDH
AutoCAD SHX Text
JDH
AutoCAD SHX Text 03/31/2026
AutoCAD SHX Text 03/31/2026
AutoCAD SHX Text 03/31/2026
AutoCAD SHX Text M
AutoCAD SHX Text
SEAL
AutoCAD SHX Text A
AutoCAD SHX Text 31466
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text C
AutoCAD SHX Text H
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text A
AutoCAD SHX Text J
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text D.
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text H
AutoCAD SHX Text
1. ELECTRICAL CONTRACTOR SHALL CIRCUIT ALL EXTERIOR POLES TO PANEL "A". RACEWAY SHALL BE 1" MINIMUM. ELECTRICAL CONTRACTOR SHALL CIRCUIT ALL EXTERIOR POLES TO PANEL "A". RACEWAY SHALL BE 1" MINIMUM. CONTRACTOR SHALL PROVIDE ALL SITE LIGHTING. 2. INSTALLATION OF POLES AND LIGHTING FIXTURES SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. INSTALLATION OF POLES AND LIGHTING FIXTURES SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 3. CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL UTILITIES PRIOR TO THE BEGINNING OF WORK AND AVOIDING THEM CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL UTILITIES PRIOR TO THE BEGINNING OF WORK AND AVOIDING THEM DURING INSTALLATION OPERATIONS. 4. MOUNTING HEIGHTS MEASURED FROM PARKING SURFACE OR GRADE AT BASE OF POLE. HEIGHTS SHOWN ARE FIXTURE MOUNTING HEIGHTS MEASURED FROM PARKING SURFACE OR GRADE AT BASE OF POLE. HEIGHTS SHOWN ARE FIXTURE HEIGHTS. 5. POLE LOCATED ADJACENT TO ROAD OR PARKING EDGES SHALL BE SET BACK 36" FROM EDGE OF PAVEMENT/GRAVEL.POLE LOCATED ADJACENT TO ROAD OR PARKING EDGES SHALL BE SET BACK 36" FROM EDGE OF PAVEMENT/GRAVEL.
AutoCAD SHX Text
REF MANF
AutoCAD SHX Text
MARK
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
QUALITY AND APPEARANCE
AutoCAD SHX Text
INPUT WATTS
AutoCAD SHX Text
FIXTURE
AutoCAD SHX Text
VOLTS
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
MULTI-VOLT INPUT
AutoCAD SHX Text
BATTERY BACK-UP - 1400 LUMENS
AutoCAD SHX Text
STANDARD COLOR SELECTED BY ARCH.
AutoCAD SHX Text
CUSTOM COLOR SELECTED BY ARCH.
AutoCAD SHX Text
LED
AutoCAD SHX Text
SOURCE
AutoCAD SHX Text
LUMENS
AutoCAD SHX Text
CRI
AutoCAD SHX Text
COLOR
AutoCAD SHX Text
TEMP
AutoCAD SHX Text
BATTERY BACK-UP
AutoCAD SHX Text
MODEL NUMBER FOR FIXTURE REFERENCE
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text
LED
AutoCAD SHX Text 25,070
AutoCAD SHX Text 40K
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AEL
AutoCAD SHX Text
ROADWAY TYPE 5
AutoCAD SHX Text
LED
AutoCAD SHX Text 36,305
AutoCAD SHX Text 40K
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AEL
AutoCAD SHX Text D
AutoCAD SHX Text
ATB0 P454 MVOLT R5 MP
AutoCAD SHX Text
ATB2 P604 MVOLT R4 MP
AutoCAD SHX Text
EXTERIOR CANOPY LIGHT
AutoCAD SHX Text
LITHONIA
AutoCAD SHX Text
PCNY LED ALO2 SWW2 FPCL MVOLT DWHXD M3
AutoCAD SHX Text
LED
AutoCAD SHX Text 40K
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ROADWAY TYPE 4
AutoCAD SHX Text 13,000
AutoCAD SHX Text
AutoCAD SHX Text
ARM
AutoCAD SHX Text
LITHONIA
AutoCAD SHX Text
AMACE T20 US2 DDBXD
AutoCAD SHX Text
2' ELLIPTICAL TUBE ARM
AutoCAD SHX Text
PROVIDE WITH 3 PIN NEMA PHOTOCELL
AutoCAD SHX Text
COLOR
AutoCAD SHX Text
DK BRONZE
AutoCAD SHX Text
DK BRONZE
AutoCAD SHX Text
QTY.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PROVIDE WITH 3 PIN NEMA PHOTOCELL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
POLE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
40' WOOD POLE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
%%UNOTES:
AutoCAD SHX Text
1. PRODUCTS LISTED ARE DESIGN BASIS. EQUAL SUBSTITUTION SUBMITTALS WILL BE EVALUATED. PRODUCTS LISTED ARE DESIGN BASIS. EQUAL SUBSTITUTION SUBMITTALS WILL BE EVALUATED. 2. CONTRACTOR SHALL SUBMIT LIGHTING PLAN SHEET WITH SCHEDULE TO SUPPLIER FOR FIXTURE SELECTION. CONTRACTOR SHALL SUBMIT LIGHTING PLAN SHEET WITH SCHEDULE TO SUPPLIER FOR FIXTURE SELECTION. 3. SUPPLIER SHALL PROVIDE LIGHTING CALCULATIONS EQUAL OR BETTER THAN SPECIFIED FIXTURES. SUPPLIER SHALL PROVIDE LIGHTING CALCULATIONS EQUAL OR BETTER THAN SPECIFIED FIXTURES. CALCULATIONS SHALL BE PROVIDED FOR BOTH SPECIFIED AND SUBSTITUTED FIXTURES FOR COMPARISON.
AutoCAD SHX Text F
AutoCAD SHX Text G
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 8,000
AutoCAD SHX Text 1,500
AutoCAD SHX Text
LED
AutoCAD SHX Text 40K
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DK BRONZE
AutoCAD SHX Text
LED
AutoCAD SHX Text 40K
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DK BRONZE
AutoCAD SHX Text
EXTERIOR CANOPY LIGHT
AutoCAD SHX Text
LITHONIA
AutoCAD SHX Text
PCNY LED ALO2 SWW2 FPCL MVOLT DWHXD M3
AutoCAD SHX Text
EXTERIOR WALL PACK
AutoCAD SHX Text
LITHONIA
AutoCAD SHX Text
ARC1 LED P1 40K MVOLT PE
AutoCAD SHX Text
DK BRONZE
AutoCAD SHX Text
DK BRONZE
AutoCAD SHX Text
PROVIDE WITH PHOTOCELL
AutoCAD SHX Text H
AutoCAD SHX Text
AutoCAD SHX Text 7,600
AutoCAD SHX Text
LED
AutoCAD SHX Text 40K
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DK BRONZE
AutoCAD SHX Text
EXTERIOR STRIP LIGHT
AutoCAD SHX Text
LITHONIA
AutoCAD SHX Text
CLX L48 7000LM SEF RDL 40K 80CRI THCLX
AutoCAD SHX Text
AutoCAD SHX Text
1. COORDINATE LOCATION OF PANEL WITH UTILITY POLES. COORDINATE LOCATION OF PANEL WITH UTILITY POLES. COORDINATE LOCATION OF SIGN WITH OWNER.
3/31/26
SCALE: N1 ELECTRICAL SITE LIGHTING PLAN
1" = 20'-0"
INSTALLATION KEYED NOTES " # ":
SCALE: N2 ELECTRICAL - EQUIPMENT SHED PLAN
1/8" = 1'-0"
E2
EL
EC
TR
IC
AL
S
IT
E
PL
AN
PANEL "A"
AutoCAD SHX Text A-18
AutoCAD SHX Text
WR
AutoCAD SHX Text
GFI
AutoCAD SHX Text A-16
AutoCAD SHX Text
WR
AutoCAD SHX Text
GFI
AutoCAD SHX Text A-16
AutoCAD SHX Text
WR
AutoCAD SHX Text
GFI
AutoCAD SHX Text A-18
AutoCAD SHX Text
WR
AutoCAD SHX Text
GFI
AutoCAD SHX Text A-30
AutoCAD SHX Text
WR
AutoCAD SHX Text
GFI
AutoCAD SHX Text A-30
AutoCAD SHX Text
WR
AutoCAD SHX Text
GFI
AutoCAD SHX Text S
AutoCAD SHX Text
WR
AutoCAD SHX Text A-31,33,35
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text A-1,3,5
AutoCAD SHX Text F
AutoCAD SHX Text A-7,9,11
AutoCAD SHX Text A-13,15,17
AutoCAD SHX Text A-19,21,23
AutoCAD SHX Text A-25,27,29
AutoCAD SHX Text A-30
AutoCAD SHX Text
VIA PHOTOCELL
AutoCAD SHX Text A-34
AutoCAD SHX Text
VIA PHOTOCELL
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text S
AutoCAD SHX Text H
AutoCAD SHX Text H
AutoCAD SHX Text H
AutoCAD SHX Text H
AutoCAD SHX Text H
AutoCAD SHX Text H
AutoCAD SHX Text
WR
AutoCAD SHX Text A-32
AutoCAD SHX Text
WR
AutoCAD SHX Text
GFI
AutoCAD SHX Text A-32
AutoCAD SHX Text
WR
AutoCAD SHX Text
GFI
AutoCAD SHX Text A-32
AutoCAD SHX Text
WR
AutoCAD SHX Text
GFI
AutoCAD SHX Text A-32
AutoCAD SHX Text
WR
AutoCAD SHX Text
GFI
AutoCAD SHX Text A-32
AutoCAD SHX Text A-32
AutoCAD SHX Text
VIA PHOTOCELL
AutoCAD SHX Text G
AutoCAD SHX Text
REV.
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
CLIENT DWG. NO.
AutoCAD SHX Text
OF
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
PROJECT/LOCATION
AutoCAD SHX Text
PROJECT NO.
AutoCAD SHX Text
APPROVED BY
AutoCAD SHX Text
CHECKED BY
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
PROJECT MGR.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
(919) 778-9064
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
REV.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
P.O. BOX 11527
AutoCAD SHX Text
BY
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
GOLDSBORO, NC 27532
AutoCAD SHX Text
TEL:
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
BEAUFORT COUNTY
AutoCAD SHX Text
PROJNO
AutoCAD SHX Text
JDH
AutoCAD SHX Text
STILLEY STATION
AutoCAD SHX Text
NC LIC #: C-1132
AutoCAD SHX Text N/A
AutoCAD SHX Text
BLT
AutoCAD SHX Text
JDH
AutoCAD SHX Text
JDH
AutoCAD SHX Text 03/31/2026
AutoCAD SHX Text 03/31/2026
AutoCAD SHX Text 03/31/2026
AutoCAD SHX Text M
AutoCAD SHX Text
SEAL
AutoCAD SHX Text A
AutoCAD SHX Text 31466
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text C
AutoCAD SHX Text H
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text A
AutoCAD SHX Text J
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text D.
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text H
AutoCAD SHX Text
AutoCAD SHX Text
1. INSTALL PHOTOCELL ON TOP CORNER OF CANOPY FACING NORTH. INSTALL PHOTOCELL ON TOP CORNER OF CANOPY FACING NORTH. 2. PROVIDE (4) RECEPTACLES IN WORK SHED. COORDINATED LOCATIONS WITH PROVIDE (4) RECEPTACLES IN WORK SHED. COORDINATED LOCATIONS WITH OWNER. 3. PROVIDE POLE LIGHTS ALONG DUMPSTER WALL AS AN ALTERNATE PRICE IF PROVIDE POLE LIGHTS ALONG DUMPSTER WALL AS AN ALTERNATE PRICE IF CANOPY IS NOT A CHOSEN. PROVIDE WITH A 30' SQUARE ALUMINUM POLE (DARK BRONZE). UTILIZE CIRCUIT "A-34". 4. PANEL "B" IS LOCATED IN THE OFFICE. PANEL FURNISHED BY OTHERS, E.C. PANEL "B" IS LOCATED IN THE OFFICE. PANEL FURNISHED BY OTHERS, E.C. SHALL PROVIDE FEEDER AND CONNECT WIRING TO PANEL.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE:5 DIRECT BURIED CONDUITS
N.T.S.
SCALE:7 TYPICAL BONDING & GROUNDING DIAGRAM
N.T.S.
SCALE:4 TYPICAL MADE GROUNDING ELECTRODE
N.T.S.
SCALE:1 SERVICE EQUIPMENT GROUNDING DIAGRAM
N.T.S.
SCALE:2 DEDICATED WORKING SPACE REQUIREMENTS
N.T.S.
SCALE:6 POLE INSTALLATION
N.T.S.
SCALE:3 ELECTRICAL DETAIL (MAIN ENTRANCE)
N.T.S.
E3
EL
EC
TR
IC
AL
D
ET
AI
LS
REV.
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
CLIENT DWG. NO.
AutoCAD SHX Text
OF
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
PROJECT/LOCATION
AutoCAD SHX Text
PROJECT NO.
AutoCAD SHX Text
APPROVED BY
AutoCAD SHX Text
CHECKED BY
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
PROJECT MGR.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
(919) 778-9064
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
REV.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
P.O. BOX 11527
AutoCAD SHX Text
BY
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
GOLDSBORO, NC 27532
AutoCAD SHX Text
TEL:
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
BEAUFORT COUNTY
AutoCAD SHX Text
PROJNO
AutoCAD SHX Text
JDH
AutoCAD SHX Text
STILLEY STATION
AutoCAD SHX Text
NC LIC #: C-1132
AutoCAD SHX Text N/A
AutoCAD SHX Text
BLT
AutoCAD SHX Text
JDH
AutoCAD SHX Text
JDH
AutoCAD SHX Text 03/31/2026
AutoCAD SHX Text 03/31/2026
AutoCAD SHX Text 03/31/2026
AutoCAD SHX Text M
AutoCAD SHX Text
SEAL
AutoCAD SHX Text A
AutoCAD SHX Text 31466
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text C
AutoCAD SHX Text H
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text A
AutoCAD SHX Text J
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text D.
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text H
AutoCAD SHX Text
SPACERS
AutoCAD SHX Text
4" DATA CONDUITS SCH 40 PVC
AutoCAD SHX Text
MARKER TAPE AND TRACER WIRE 12" ABOVE CONDUITS
AutoCAD SHX Text
24" MIN
AutoCAD SHX Text
CLEAN NATIVE SOIL OR SAND BACK FILL
AutoCAD SHX Text
EARTH FILL
AutoCAD SHX Text NOTES: 1. DIRECT BURIED CONDUITS APPLY TO BRANCH CIRCUITS FROM DIRECT BURIED CONDUITS APPLY TO BRANCH CIRCUITS FROM PANELBOARDS, DATA, AND SECURITY RACEWAYS. 2. UNDERGROUND WARNING TAPE: PROVIDE WATERPROOF MARKING CORD UNDERGROUND WARNING TAPE: PROVIDE WATERPROOF MARKING CORD (130-POUND TENSILE TEST MARKED AT LEAST EVERY FOOT EQUIVALENT TO GREENLEE NO. 435) IN ALL DUCTS, INCLUDING SPARES, ONCE CLEAN AND FREE OF OBSTRUCTIONS. INSTALL WARNING TAPE 24" ABOVE RACEWAY, OR 12" BELOW GRADE IF CONDUIT IS BURIED 24" BELOW GRADE. 3. PROVIDE GRC CONDUIT ELBOWS AT TURN UP TO EQUIPMENT AND AT PROVIDE GRC CONDUIT ELBOWS AT TURN UP TO EQUIPMENT AND AT BUILDING ENTRANCES THROUGH FLOOR. 4. THIS DETAIL IS TYPICAL FOR ALL CONDUITS REGARDLESS OF QUANTITY. THIS DETAIL IS TYPICAL FOR ALL CONDUITS REGARDLESS OF QUANTITY. SEE PLANS FOR EXACT SIZES AND QUANTITY.
AutoCAD SHX Text
%%UNOTES:
AutoCAD SHX Text
1. GROUNDING ELECTRODE CONDUCTOR SHALL BE RUN CONTINUOUSLY (UNBROKEN) GROUNDING ELECTRODE CONDUCTOR SHALL BE RUN CONTINUOUSLY (UNBROKEN) FROM COLD WATER LINE AND/OR BUILDING STEEL AND GROUND ROD TO GROUND BAR BEFORE BONDING TO ANY CONDUIT BUSHING. 2. ALL THE FOLLOWING GROUNDING ELECTRODES THAT ARE AVAILABLE SHALL BE ALL THE FOLLOWING GROUNDING ELECTRODES THAT ARE AVAILABLE SHALL BE BONDED TOGETHER TO FORM THE GROUNDING ELECTRODE SYSTEM PER NEC 250.52: 2.1. METAL UNDERGROUND WATER PIPE IN DIRECT CONTACT WITH EARTH FOR 10 FT METAL UNDERGROUND WATER PIPE IN DIRECT CONTACT WITH EARTH FOR 10 FT OR MORE 2.2. METAL FRAME OF THE BUILDING, METAL FRAME OF THE BUILDING, 2.3. ANY ELECTRODE ENCASED BY AT LEAST 2 IN. OF CONCRETE, CONSISTING OF ANY ELECTRODE ENCASED BY AT LEAST 2 IN. OF CONCRETE, CONSISTING OF 20 FT OR MORE BARE OR ZINC GALVANIZED OR OTHER ELECTRICALLY CONDUCTIVE COATED STEEL REINFORCING BARS OR RODS NOT LESS THAN 1/2" IN DIAMETER. 2.4. GROUND RING ENCIRCLING THE BUILDING GROUND RING ENCIRCLING THE BUILDING 2.5. ROD AND PIPE ELECTRODES NOT LESS THAN 8 FT. ROD AND PIPE ELECTRODES NOT LESS THAN 8 FT. 2.6. PLATE ELECTRODESPLATE ELECTRODES
AutoCAD SHX Text MAIN BONDING JUMPER - PROVIDE AT FACTORY OR SIZED PER NEC TABLE 250-102(C)(1)250-102(C)(1)
AutoCAD SHX Text
INCOMING NEUTRAL/GROUND CONDUCTOR
AutoCAD SHX Text
LIGHTING OR POWER PANELBOARD CABINET (208 VOLT)
AutoCAD SHX Text
GROUND BAR
AutoCAD SHX Text
BUSHING
AutoCAD SHX Text
LOCKNUT
AutoCAD SHX Text
LOCKNUT
AutoCAD SHX Text
CONDUIT
AutoCAD SHX Text
PANEL CAN OR ENCLOSURE
AutoCAD SHX Text
CONDUIT
AutoCAD SHX Text
NEUTRAL BAR (NOT GROUNDED HERE)
AutoCAD SHX Text
NEUTRAL BAR
AutoCAD SHX Text
NEUTRAL
AutoCAD SHX Text
PLASTIC BUSHING
AutoCAD SHX Text
GROUND
AutoCAD SHX Text
CONNECTION (TYPICAL)
AutoCAD SHX Text
GROUND BAR
AutoCAD SHX Text
MAIN (208 VOLT) PANELBOARD OR SWITCHBOARD CABINET
AutoCAD SHX Text
BONDING BUSHING
AutoCAD SHX Text
SERVICE ENTRANCE CONDUIT
AutoCAD SHX Text
GROUND BAR
AutoCAD SHX Text
GROUND
AutoCAD SHX Text
NEUTRAL
AutoCAD SHX Text
PLASTIC BUSHING
AutoCAD SHX Text
EQUIVALENT CONNECTION (TYPICAL)
AutoCAD SHX Text
10' MIN.
AutoCAD SHX Text
(TYPICAL)
AutoCAD SHX Text
10' X 3/4" (THREE REQUIRED)
AutoCAD SHX Text
COPPERCLAD OR COPPERWELD STEEL ROD,
AutoCAD SHX Text
TO SERVICE EQUIPMENT
AutoCAD SHX Text 2'-0"
AutoCAD SHX Text
AS SHOWN ON POWER
AutoCAD SHX Text
RISER DIAGRAM & GROUNDING SCHEMATIC
AutoCAD SHX Text
CADWELD, THERMOWELD OR
AutoCAD SHX Text
GRADE
AutoCAD SHX Text
MIN. #3/0 BARE STRANDED COPPER, UNO. BURY 30" BELOW GRADE.
AutoCAD SHX Text
SERVICE EQUIPMENT NEUTRAL BAR
AutoCAD SHX Text
JUMPER
AutoCAD SHX Text
WATER VALVE
AutoCAD SHX Text
BUILDING STRUCTURE
AutoCAD SHX Text
GROUND CLAMP
AutoCAD SHX Text
EXOTHERMIC WELD
AutoCAD SHX Text
GROUND CONDUCTOR
AutoCAD SHX Text
TO FOOTING REINFORCING STEEL IF ACCESSIBLE
AutoCAD SHX Text
(MAX REQUIRED SIZE #4 AWG)
AutoCAD SHX Text
JUMPER SIZED PER NEC TABLE 250-66 OR 250-28D
AutoCAD SHX Text
BUS-BAR OR CONDUCTOR
AutoCAD SHX Text
GROUND BUSHING ON METALLIC CONDUITS
AutoCAD SHX Text
SUPPLY SIDE
AutoCAD SHX Text
(3) 3/4" x 10' GROUND RODS
AutoCAD SHX Text
TABLE 250.122
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
#6 BARE COPPER
AutoCAD SHX Text
GROUNDING CONDUCTOR SIZE = #1/0 AWG
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EXOTHERMIC WELD
AutoCAD SHX Text 4"x24"x1/4" THICK COPPER GROUND BAR UL LISTED AND FACTORY DRILLED
AutoCAD SHX Text NOTES: 1. ALL UNDERGROUND CONNECTIONS SHALL BE EXOTHERMIC WELDS OR IRREVERSIBLE ALL UNDERGROUND CONNECTIONS SHALL BE EXOTHERMIC WELDS OR IRREVERSIBLE COMPRESSION CONNECTIONS, EXCEPT MECHANICAL CONNECTIONS IN TEST WELLS. 2. LABEL RACEWAYS OR CONDUCTORS AT GROUND BUS WITH PHENOLIC TAGS TO IDENTIFY LABEL RACEWAYS OR CONDUCTORS AT GROUND BUS WITH PHENOLIC TAGS TO IDENTIFY CONNECTION LOCATION SUCH AS: "GAS PIPING", "GROUND RODS" OR "BUILDING STEEL".
AutoCAD SHX Text %%uALL ELECTRIC EQUIPMENT
AutoCAD SHX Text 1 2 3
AutoCAD SHX Text
VOLTAGE TO GROUND
AutoCAD SHX Text
WORKING CLEARANCES
AutoCAD SHX Text
(NOMINAL)
AutoCAD SHX Text 151-600
AutoCAD SHX Text 0-150
AutoCAD SHX Text
(MINIMUM CLEAR DISTANCE)
AutoCAD SHX Text
TABLE "A"
AutoCAD SHX Text 3'
AutoCAD SHX Text 3'
AutoCAD SHX Text
CONDITION:
AutoCAD SHX Text 3'
AutoCAD SHX Text 3 1/2'
AutoCAD SHX Text 25'-0"
AutoCAD SHX Text
SEE TABLE "A"
AutoCAD SHX Text
THIS DISTANCE
AutoCAD SHX Text
LIGHT FIXTURE
AutoCAD SHX Text
WALL
AutoCAD SHX Text %%uPANELBOARDS
AutoCAD SHX Text
LIGHT FIXTURE
AutoCAD SHX Text
PANELBOARD
AutoCAD SHX Text
WALL
AutoCAD SHX Text 4'
AutoCAD SHX Text 3'
AutoCAD SHX Text WHERE THE "CONDITIONS" ARE AS FOLLOWS: 1. EXPOSED LIVE PARTS ON ONE SIDE AND NO LIVE OR GROUNDED PARTS ON THE EXPOSED LIVE PARTS ON ONE SIDE AND NO LIVE OR GROUNDED PARTS ON THE OTHER SIDE OF THE WORKING SPACE, OR EXPOSED LIVE PARTS ON BOTH SIDES EFFECTIVELY GUARDED BY SUITABLE WOOD OR OTHER INSULATING MATERIALS. INSULATED WIRE OR INSULATED BUSBARS OPERATING AT NOT OVER 300 VOLTS SHALL NOT BE CONSIDERED LIVE PARTS. 2. EXPOSED LIVE PARTS ON ONE SIDE AND GROUNDED PARTS ON THE OTHER SIDE. EXPOSED LIVE PARTS ON ONE SIDE AND GROUNDED PARTS ON THE OTHER SIDE. 3. EXPOSED LIFE PARTS ON BOTH SIDES OF THE WORK SPACE (NOT GUARDED AS EXPOSED LIFE PARTS ON BOTH SIDES OF THE WORK SPACE (NOT GUARDED AS PROVIDED IN CONDITION 1) WITH THE OPERATOR BETWEEN.
AutoCAD SHX Text DEDICATED SPACE CONTINUES THROUGH SUSPENDED CEILING TO 6' ABOVE ELECTRICAL EQUIPMENT OR STRUCTURAL CEILING, WHICHEVER IS LOWER.
AutoCAD SHX Text
STRUCTURAL CEILING
AutoCAD SHX Text
SUSPENDED CEILING
AutoCAD SHX Text
EXCLUSIVELY DEDICATED SPACE
AutoCAD SHX Text
EXCLUSIVELY DEDICATED SPACE
AutoCAD SHX Text
STRUCTURAL CEILING
AutoCAD SHX Text
SUSPENDED CEILING
AutoCAD SHX Text
EXCLUSIVELY DEDICATED SPACE
AutoCAD SHX Text
ELECTRIC EQUIPMENT
AutoCAD SHX Text
PLANE OF FRONT EDGE OF ELECTRIC EQUIPMENT
AutoCAD SHX Text
6 1/2' MINIMUM OR HEIGHT OF EQUIPMENT
AutoCAD SHX Text 30" OR WIDTH OF EQUIPMENT IF EQUIPMENT IS WIDER THAN 30" DOES NOT HAVE TO BE CENTERED ON THE EQUIPMENT BUT AT LEAST EVEN WITH ONE EDGE. EQUIPMENT DOOR SHALL BE ABLE TO OPEN AT LEAST 90°.
AutoCAD SHX Text NOTES: 1. THIS FIGURE ILLUSTRATES THE ADDITIONAL EXCLUSIVELY THIS FIGURE ILLUSTRATES THE ADDITIONAL EXCLUSIVELY DEDICATED SPACE REQUIRED OVER AND UNDER PANELBOARDS FOR CABLES, RACEWAYS, ETC. TO AND FROM PANELBOARDS REQUIRED BY NEC SECTION 110-26. 2. NO PIPING DUCTWORK OR EQUIPMENT FOREIGN TO THE NO PIPING DUCTWORK OR EQUIPMENT FOREIGN TO THE ELECTRICAL EQUIPMENT OR ARCHITECTURAL APPURTENANCES SHALL BE PERMITTED TO BE INSTALLED IN, ENTER OR PASS THROUGH THE DEDICATED SPACES SHOWN. FOR EXCEPTIONS SEE NEC SECTION 110-26f.
AutoCAD SHX Text NOTES: 1. THIS FIGURE ILLUSTRATES THE WORKING SPACE IN THIS FIGURE ILLUSTRATES THE WORKING SPACE IN FRONT OF ELECTRICAL EQUIPMENT REQUIRED BY NEC SECTION 110-26. 2. THIS INCLUDES BUT IS NOT LIMITED TO PANELBOARDS, THIS INCLUDES BUT IS NOT LIMITED TO PANELBOARDS, SAFETY SWITCHES, MOTOR STARTERS, JUNCTION BOXES AND OTHER ELECTRICAL EQUIPMENT.
AutoCAD SHX Text 34'
AutoCAD SHX Text
NEMA 3R JUNCTION
AutoCAD SHX Text
BOX (TYP.)
AutoCAD SHX Text
#8 IN 1" PVC
AutoCAD SHX Text
(2) #12, (1) #12 IN 1/2" PVC
AutoCAD SHX Text
PROVIDE 40' CLASS 5 TREATED WOOD POLES
AutoCAD SHX Text
PROVIDE FIXTURE, BRACKETS & HARDWARE
AutoCAD SHX Text
GRADE
AutoCAD SHX Text 6'
AutoCAD SHX Text
1" PVC TO ALL POLES.
AutoCAD SHX Text
%%UNOTES:
AutoCAD SHX Text
1. SETTING POLES ON SLOPING GROUND, MEASURE THE DEPTH OF THE HOLE FROM SETTING POLES ON SLOPING GROUND, MEASURE THE DEPTH OF THE HOLE FROM THE LOW SIDE OF THE HOLE. 2. TAMP POLE BACKFILL FOR THE FULL DEPTH OF THE HOLE AND MOUND THE TAMP POLE BACKFILL FOR THE FULL DEPTH OF THE HOLE AND MOUND THE EXCESS FILL AROUND THE POLE. 3. WOOD POLES SHALL BE INSPECTED AND COMPLY WITH ANSI O5.1 AND RUS BULL WOOD POLES SHALL BE INSPECTED AND COMPLY WITH ANSI O5.1 AND RUS BULL 1728F-700. GAIN, BORE, AND ROOF POLES BEFORE TREATMENT. TREAT FULL LENGTH WITH CCA OR ACA ACCORDING TO AWPA T1 AND AWPA U1. PROVIDE POLES BRANDED BY MANUFACTURER WITH MANUFACTURER'S MARK AND DATE OF TREATMENT, HEIGHT AND CLASS OF POLE, WOOD SPECIES, PRESERVATION CODE, AND RETENTION.
AutoCAD SHX Text
6" X 6" PRESSURE TREATED TIMBER OR PRESSURE TREATED POLE
AutoCAD SHX Text
WEATHERHEAD
AutoCAD SHX Text
ATTACHMENT POINT
AutoCAD SHX Text
DUKE ENERGY SERVICE CABLE
AutoCAD SHX Text
POINT OF DELIVERY
AutoCAD SHX Text
RISER
AutoCAD SHX Text
METER ENCLOSURE
AutoCAD SHX Text
PANELBOARD
AutoCAD SHX Text
GROUND WIRE
AutoCAD SHX Text
FINAL GRADE
AutoCAD SHX Text
4' TO 5'-6"
AutoCAD SHX Text
14' MIN.
AutoCAD SHX Text
20'-0" CLASS 10
AutoCAD SHX Text
5'-0" POLE DEPTH
AutoCAD SHX Text
* TYPICAL GROUNDING ELECTRODE PER N.E.C. (SEE FIG. 14A)
AutoCAD SHX Text
* UPPER END OF GROUND ROD SHALL BE FLUSH WITH OR BELOW FINAL GRADE UNLESS THE ROD END AND GROUND CONDUCTOR ATTACHMENT ARE PROTECTED AGAINST PHYSICAL DAMAGE.
AutoCAD SHX Text NOTES: : 1. UTILITY COMPANY FURNISHES AND INSTALLS SERVICE UTILITY COMPANY FURNISHES AND INSTALLS SERVICE CABLE AND APPROPRIATE METER. 2. CONTRACTOR FURNISHES AND INSTALLS PROPERLY CONTRACTOR FURNISHES AND INSTALLS PROPERLY SIZED TIMBER/POLE, RISER, WEATHERHEAD, ATTACHMENT POINT, METER ENCLOSURE, GROUNDING AND ALL OTHER ITEMS BEYOND POINT OF DELIVERY.
PANELBOARD SCHEDULESERVICE LOAD SUMMARY (PANELBOARD "A")
SCALE:1 ELECTRICAL RISER
N.T.S.
INSTALLATION KEYED NOTES " # ":
SCALE:2 ELECTRICAL RISER (MAIN ENTRANCE)
N.T.S.
PANELBOARD SCHEDULE
SCALE:3 SERVICE EQUIPMENT SUPPORT DETAIL
N.T.S. E4
EL
EC
TR
IC
AL
R
IS
ER
S
SC
H
ED
U
LE
S
AutoCAD SHX Text
REV.
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
CLIENT DWG. NO.
AutoCAD SHX Text
OF
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
PROJECT/LOCATION
AutoCAD SHX Text
PROJECT NO.
AutoCAD SHX Text
APPROVED BY
AutoCAD SHX Text
CHECKED BY
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
PROJECT MGR.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
(919) 778-9064
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
REV.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
P.O. BOX 11527
AutoCAD SHX Text
BY
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
GOLDSBORO, NC 27532
AutoCAD SHX Text
TEL:
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
BEAUFORT COUNTY
AutoCAD SHX Text
PROJNO
AutoCAD SHX Text
JDH
AutoCAD SHX Text
STILLEY STATION
AutoCAD SHX Text
NC LIC #: C-1132
AutoCAD SHX Text N/A
AutoCAD SHX Text
BLT
AutoCAD SHX Text
JDH
AutoCAD SHX Text
JDH
AutoCAD SHX Text 03/31/2026
AutoCAD SHX Text 03/31/2026
AutoCAD SHX Text 03/31/2026
AutoCAD SHX Text M
AutoCAD SHX Text
SEAL
AutoCAD SHX Text A
AutoCAD SHX Text 31466
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text C
AutoCAD SHX Text H
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text A
AutoCAD SHX Text J
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text D.
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text H
AutoCAD SHX Text
LOAD SERVED
AutoCAD SHX Text
WIRE SIZE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
WIRE SIZE
AutoCAD SHX Text
LOAD (AMPS)
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text
NO.
AutoCAD SHX Text
CKT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
22K AIC
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text
PHASE
AutoCAD SHX Text
NO.
AutoCAD SHX Text
CKT
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text
AutoCAD SHX Text
LOAD SERVED
AutoCAD SHX Text
LOAD (AMPS)
AutoCAD SHX Text
CONDUIT
AutoCAD SHX Text
SIZE
AutoCAD SHX Text
CONDUIT
AutoCAD SHX Text
SIZE
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text
BREAKER
AutoCAD SHX Text 3R
AutoCAD SHX Text
MAIN
AutoCAD SHX Text
PANEL
AutoCAD SHX Text
NEMA
AutoCAD SHX Text
MOUNTED
AutoCAD SHX Text
COPPER BUS
AutoCAD SHX Text
FEED
AutoCAD SHX Text
SURFACE
AutoCAD SHX Text
BOTTOM
AutoCAD SHX Text
VOLT
AutoCAD SHX Text
AMP (FEEDER SIZE)
AutoCAD SHX Text 120/208
AutoCAD SHX Text
AutoCAD SHX Text
3%%C, 4 WIRE
AutoCAD SHX Text
BOLT ON BREAKER
AutoCAD SHX Text
AMP (BUS RATING)
AutoCAD SHX Text
AutoCAD SHX Text
SERVICE ENTRANCE RATED
AutoCAD SHX Text
COMPACTOR #6
AutoCAD SHX Text 3#2 & 1#6G
AutoCAD SHX Text 1 1/2"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SHED LTS & RECP.
AutoCAD SHX Text
MULTI-MAT. LIGHTING
AutoCAD SHX Text
SPARE
AutoCAD SHX Text
SPARE
AutoCAD SHX Text
SPARE
AutoCAD SHX Text
SPARE
AutoCAD SHX Text
SPARE
AutoCAD SHX Text
RECEPTACLES
AutoCAD SHX Text
RECEPTACLES
AutoCAD SHX Text
SPARE
AutoCAD SHX Text 2#4 & 1#4G
AutoCAD SHX Text 2#10 & 1#10G
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 2#4 & 1#4G
AutoCAD SHX Text 2#8 & 1#8G
AutoCAD SHX Text
AutoCAD SHX Text 1 1/2"
AutoCAD SHX Text 1"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1"
AutoCAD SHX Text 1"
AutoCAD SHX Text
AutoCAD SHX Text
DROP-OFF LTG
AutoCAD SHX Text 2#8 & 1#8G
AutoCAD SHX Text 1"
AutoCAD SHX Text
SPARE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SPARE
AutoCAD SHX Text
PANEL B
AutoCAD SHX Text 3#3 & 1#8G.
AutoCAD SHX Text 2"
AutoCAD SHX Text COORDINATE BREAKERS AND WIRE SIZES FOR OWNER FURNISHED EQUIPMENT WITH SUBMITTALS PROVIDE SEPARATE NEUTRALS FOR ALL CIRCUITS.
AutoCAD SHX Text
1 HORSEPOWER UNKNOWN. CONTRACTOR TO VERIFY WIRE AND BREAKER SIZES.
AutoCAD SHX Text 2 PROVIDE JUNCTION BOX AT DEVICE TO ALLOW SPLICE IN WIRING DOWN TO MATCH DEVICE RATINGS.
AutoCAD SHX Text
3 WIRE LIGHTS THROUGH PHOTOCELL.
AutoCAD SHX Text
AutoCAD SHX Text
COMPACTOR #1
AutoCAD SHX Text 3#2 & 1#6G
AutoCAD SHX Text 1 1/2"
AutoCAD SHX Text
COMPACTOR #2
AutoCAD SHX Text 3#6 & 1#8G
AutoCAD SHX Text 1 1/2"
AutoCAD SHX Text
COMPACTOR #3
AutoCAD SHX Text 3#4 & 1#6G
AutoCAD SHX Text 1 1/2"
AutoCAD SHX Text
COMPACTOR #4
AutoCAD SHX Text 3#4 & 1#6G
AutoCAD SHX Text 1 1/2"
AutoCAD SHX Text
COMPACTOR #5
AutoCAD SHX Text 3#6 & 1#8G
AutoCAD SHX Text 1 1/2"
AutoCAD SHX Text
SPARE
AutoCAD SHX Text
AutoCAD SHX Text
SITE LIGHTING
AutoCAD SHX Text 2#6 & 1#6G
AutoCAD SHX Text 1"
AutoCAD SHX Text
SITE LIGHITING
AutoCAD SHX Text 2#8 & 1#8G
AutoCAD SHX Text 1"
AutoCAD SHX Text
SITE LIGHTING
AutoCAD SHX Text 2#6 & 1#6G
AutoCAD SHX Text 1"
AutoCAD SHX Text
(MULTI-MATERIAL)
AutoCAD SHX Text
(PRECRUSHER)
AutoCAD SHX Text
(PRECRUSHER)
AutoCAD SHX Text
30HP
AutoCAD SHX Text
30HP
AutoCAD SHX Text
15HP
AutoCAD SHX Text
15HP
AutoCAD SHX Text
15HP
AutoCAD SHX Text
15HP
AutoCAD SHX Text 1 1/2"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text X
AutoCAD SHX Text 0.208
AutoCAD SHX Text
KVA
AutoCAD SHX Text
AMPS
AutoCAD SHX Text
0.208 x
AutoCAD SHX Text
KVA (TRANSFORMER)
AutoCAD SHX Text 3 x %%%Z
AutoCAD SHX Text
AutoCAD SHX Text
AMPS
AutoCAD SHX Text
FAULT CURRENT @ TRANSFORMER SECONDARY TERMINALS
AutoCAD SHX Text
SERVICE LOAD
AutoCAD SHX Text 1.5
AutoCAD SHX Text 27,800
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
OCCUPANCY TYPE - SITE LIGHTINGSITE LIGHTING
AutoCAD SHX Text
BUILDING AREA - XX SQUARE FEETXX SQUARE FEET
AutoCAD SHX Text
CONTINUOUS LOAD DESCRIPTION
AutoCAD SHX Text
LOAD (KVA)
AutoCAD SHX Text
NEC REFERENCE
AutoCAD SHX Text
DEMAND FACTOR
AutoCAD SHX Text
NEC REFERENCE
AutoCAD SHX Text
LOAD (KVA)
AutoCAD SHX Text
INDOOR LIGHTING
AutoCAD SHX Text 1.0
AutoCAD SHX Text
TABLE 220.12
AutoCAD SHX Text 100%
AutoCAD SHX Text
TABLE 220.42
AutoCAD SHX Text 1.0
AutoCAD SHX Text
OUTDOOR LIGHTING
AutoCAD SHX Text 7.5
AutoCAD SHX Text
AutoCAD SHX Text 100%
AutoCAD SHX Text
AutoCAD SHX Text 7.5
AutoCAD SHX Text
SIGN LIGHTING
AutoCAD SHX Text 1.2
AutoCAD SHX Text
220.14 F
AutoCAD SHX Text 100%
AutoCAD SHX Text
AutoCAD SHX Text 1.2
AutoCAD SHX Text
LARGEST COMPACTOR MOTOR (30HP)
AutoCAD SHX Text 33.0
AutoCAD SHX Text
ARTICLE 430
AutoCAD SHX Text 100%
AutoCAD SHX Text
AutoCAD SHX Text 33.0
AutoCAD SHX Text
PACKAGED HVAC UNITS
AutoCAD SHX Text 3.5
AutoCAD SHX Text
ARTICLE 440
AutoCAD SHX Text 100%
AutoCAD SHX Text
AutoCAD SHX Text 3.5
AutoCAD SHX Text
AIR HANDLER FANS (SPLIT SYSTEMS)
AutoCAD SHX Text
ARTICLE 440
AutoCAD SHX Text 100%
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AIR HANDLER ELECTRIC HEAT
AutoCAD SHX Text 422.12
AutoCAD SHX Text 100%
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE BUILDING
AutoCAD SHX Text 12.0
AutoCAD SHX Text
AutoCAD SHX Text 100%
AutoCAD SHX Text
AutoCAD SHX Text 12.0
AutoCAD SHX Text
SUBTOTAL CONTINUOUS LOADS
AutoCAD SHX Text 58.2
AutoCAD SHX Text
230.42 A 1
AutoCAD SHX Text x 125%
AutoCAD SHX Text
CONT. LOAD TOTAL
AutoCAD SHX Text 72.8
AutoCAD SHX Text
NON CONTINUOUS LOAD DESCRIPTION
AutoCAD SHX Text
RECEPTACLES UP TO 10 KVA
AutoCAD SHX Text 1.6
AutoCAD SHX Text
220.14 1
AutoCAD SHX Text 100% OF 1st 10 KVA
AutoCAD SHX Text 1.6
AutoCAD SHX Text
RECEPTACLES OVER 10 KVA
AutoCAD SHX Text 0.0
AutoCAD SHX Text
220.14 1
AutoCAD SHX Text
50% ABOVE 10 KVA
AutoCAD SHX Text 0.0
AutoCAD SHX Text
COMPACTOR MOTORS (1-30HP & 3-15HP)
AutoCAD SHX Text 84.0
AutoCAD SHX Text
AutoCAD SHX Text DIVERSITY x 80%
AutoCAD SHX Text 67.2
AutoCAD SHX Text
FUTURE COMPACTOR MOTOR (1)
AutoCAD SHX Text 15.0
AutoCAD SHX Text
AutoCAD SHX Text DIVERSITY x 20%
AutoCAD SHX Text 3.0
AutoCAD SHX Text
MISC. LOADS
AutoCAD SHX Text 0.0
AutoCAD SHX Text
AutoCAD SHX Text NONCONTINUOUS LOAD x 100%
AutoCAD SHX Text 0.0
AutoCAD SHX Text
SUBTOTAL NON-CONTINUOUS LOADS
AutoCAD SHX Text 71.8
AutoCAD SHX Text
TOTAL CONTINUOUS AND NON CONTINUOUS LOADS
AutoCAD SHX Text 144.6
AutoCAD SHX Text 120/208V 3%%C
AutoCAD SHX Text
TRANSFORMER
AutoCAD SHX Text
NEW UTILITY
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CP-1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CP-2
AutoCAD SHX Text 3R
AutoCAD SHX Text
400 AMP
AutoCAD SHX Text
BREAKER
AutoCAD SHX Text
MAIN
AutoCAD SHX Text
4 WIRE
AutoCAD SHX Text 120/208V
AutoCAD SHX Text 3%%C
AutoCAD SHX Text #1/0G
AutoCAD SHX Text
PANEL A
AutoCAD SHX Text M
AutoCAD SHX Text
CT CABINET
AutoCAD SHX Text
4#500 IN 3"C.
AutoCAD SHX Text
1. COORDINATE WITH UTILITY FOR UNDERGROUND CONDUIT COORDINATE WITH UTILITY FOR UNDERGROUND CONDUIT REQUIREMENTS.
AutoCAD SHX Text
NEW
AutoCAD SHX Text
PANEL BY OTHERS
AutoCAD SHX Text
GROUND RODS
AutoCAD SHX Text 3R
AutoCAD SHX Text
CP-3
AutoCAD SHX Text 3R
AutoCAD SHX Text
CP-4
AutoCAD SHX Text 3R
AutoCAD SHX Text
CP-5
AutoCAD SHX Text 3R
AutoCAD SHX Text
CP-6
AutoCAD SHX Text 3R
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
100 AMP
AutoCAD SHX Text
BREAKER
AutoCAD SHX Text
MAIN
AutoCAD SHX Text
4 WIRE
AutoCAD SHX Text 120/208V
AutoCAD SHX Text 3%%C
AutoCAD SHX Text
PANEL B
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text 2(3)"C.
AutoCAD SHX Text
WIRING BY UTILITY CO.
AutoCAD SHX Text
3#3 & 1#8G. IN 2"C.
AutoCAD SHX Text
TRANSFORMER
AutoCAD SHX Text
UTILITY
AutoCAD SHX Text
NEW
AutoCAD SHX Text 240V 1%%C
AutoCAD SHX Text M
AutoCAD SHX Text
WIRING BY UTILITY CO.
AutoCAD SHX Text
4#3 IN 2"C.
AutoCAD SHX Text
NEW
AutoCAD SHX Text
METER
AutoCAD SHX Text
LOAD SERVED
AutoCAD SHX Text
WIRE SIZE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
WIRE SIZE
AutoCAD SHX Text
LOAD (AMPS)
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text
NO.
AutoCAD SHX Text
CKT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
10K AIC
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text
PHASE
AutoCAD SHX Text
NO.
AutoCAD SHX Text
CKT
AutoCAD SHX Text
AutoCAD SHX Text
LOAD SERVED
AutoCAD SHX Text
LOAD (AMPS)
AutoCAD SHX Text
CONDUIT
AutoCAD SHX Text
SIZE
AutoCAD SHX Text
CONDUIT
AutoCAD SHX Text
SIZE
AutoCAD SHX Text
AutoCAD SHX Text C
AutoCAD SHX Text
BREAKER
AutoCAD SHX Text 3R
AutoCAD SHX Text
MAIN
AutoCAD SHX Text
PANEL
AutoCAD SHX Text
NEMA
AutoCAD SHX Text
MOUNTED
AutoCAD SHX Text
COPPER BUS
AutoCAD SHX Text
FEED
AutoCAD SHX Text
SURFACE
AutoCAD SHX Text
TOP
AutoCAD SHX Text
VOLT
AutoCAD SHX Text
AMP (FEEDER SIZE)
AutoCAD SHX Text 120/240
AutoCAD SHX Text
AutoCAD SHX Text
1%%C, 3 WIRE
AutoCAD SHX Text
BOLT ON BREAKER
AutoCAD SHX Text
AMP (BUS RATING)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SPARE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SPARE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SPARE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SPARE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SPARE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
GATE MOTOR
AutoCAD SHX Text 2#12 & 1#12G
AutoCAD SHX Text 1"
AutoCAD SHX Text
SITE SIGN
AutoCAD SHX Text 2#12 & 1#12G
AutoCAD SHX Text 1"
AutoCAD SHX Text COORDINATE BREAKERS AND WIRE SIZES FOR OWNER FURNISHED EQUIPMENT WITH SUBMITTALS PROVIDE SEPARATE NEUTRALS FOR ALL CIRCUITS.
AutoCAD SHX Text
1 HORSEPOWER UNKNOWN. CONTRACTOR TO VERIFY WIRE AND BREAKER SIZES.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text #4G
AutoCAD SHX Text
(3) NEW
AutoCAD SHX Text
GROUND RODS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 12" x30" DEEPCONCRETE CAISSON
AutoCAD SHX Text
POST CAP
AutoCAD SHX Text
2" GALVANIZED POST
AutoCAD SHX Text
1 5/8" MIN, 12 GA. HOT DIP SUPPORT CHANNEL
AutoCAD SHX Text
TO UTILITY POLE
AutoCAD SHX Text
PANELBOARD "A"
AutoCAD SHX Text
METER
AutoCAD SHX Text CT CABINET 30"x30" PROVIDE 3/4" PLYWOOD BACKER
AutoCAD SHX Text
GROUND
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SPARE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
LOAD (KVA)
AutoCAD SHX Text
OUTDOOR LIGHTING
AutoCAD SHX Text
AutoCAD SHX Text
GROSS PHASE TOTALS (AMPS) A = 12 B = 12
AutoCAD SHX Text
CONNECTED
AutoCAD SHX Text
LOAD (KVA)
AutoCAD SHX Text
DEMAND
AutoCAD SHX Text
TOTALS:
AutoCAD SHX Text
= 2.9 KVA
AutoCAD SHX Text
DEMAND
AutoCAD SHX Text
FACTOR
AutoCAD SHX Text
MINIMUM PANEL SIZE: 3 KVA X 125%%% = 4 KVA (15 AMPS)
AutoCAD SHX Text = 1.4
AutoCAD SHX Text
DEDICATED RECP/EQUIP
AutoCAD SHX Text
INDOOR LIGHTING
AutoCAD SHX Text
AutoCAD SHX Text 100%
AutoCAD SHX Text 100%
AutoCAD SHX Text 100%%%
AutoCAD SHX Text
SIGN
AutoCAD SHX Text = 1.4
AutoCAD SHX Text 100%
AutoCAD SHX Text
= 2.9 KVA
AutoCAD SHX Text = 1.4
AutoCAD SHX Text = 1.4
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
100 AMP
AutoCAD SHX Text
NEMA 3R
AutoCAD SHX Text
MAIN BKR
AutoCAD SHX Text
3 WIRE
AutoCAD SHX Text 120/240V
AutoCAD SHX Text 1%%C
AutoCAD SHX Text
PANEL C
AutoCAD SHX Text
NEW
ELECTRICAL NOTESELECTRICAL LEGEND
SCALE:1 POLE BASE DETAIL (ALT @ DUMPTERS)
N.T.S. E5
EL
EC
TR
IC
AL
N
O
TE
S
AutoCAD SHX Text
REV.
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
CLIENT DWG. NO.
AutoCAD SHX Text
OF
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
PROJECT/LOCATION
AutoCAD SHX Text
PROJECT NO.
AutoCAD SHX Text
APPROVED BY
AutoCAD SHX Text
CHECKED BY
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
PROJECT MGR.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
(919) 778-9064
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
REV.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
P.O. BOX 11527
AutoCAD SHX Text
BY
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
GOLDSBORO, NC 27532
AutoCAD SHX Text
TEL:
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
BEAUFORT COUNTY
AutoCAD SHX Text
PROJNO
AutoCAD SHX Text
JDH
AutoCAD SHX Text
STILLEY STATION
AutoCAD SHX Text
NC LIC #: C-1132
AutoCAD SHX Text N/A
AutoCAD SHX Text
BLT
AutoCAD SHX Text
JDH
AutoCAD SHX Text
JDH
AutoCAD SHX Text 03/31/2026
AutoCAD SHX Text 03/31/2026
AutoCAD SHX Text 03/31/2026
AutoCAD SHX Text M
AutoCAD SHX Text
SEAL
AutoCAD SHX Text A
AutoCAD SHX Text 31466
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text C
AutoCAD SHX Text H
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text A
AutoCAD SHX Text J
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text D.
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text H
AutoCAD SHX Text : GENERAL 1. ELECTRICAL PLANS ARE INTENDED TO PROVIDE INFORMATION FOR INSTALLATION OF A ELECTRICAL PLANS ARE INTENDED TO PROVIDE INFORMATION FOR INSTALLATION OF A COMPLETE ELECTRICAL SYSTEM. PROVIDE ALL ESSENTIAL LABOR, MATERIALS & DEVICES REQUIRED TO PRODUCE A QUALITY END PRODUCT. THIS INCLUDES ALL REQUIRED CONTROL WIRING OR WIRING CALLED FOR BY THE MANUFACTURER AND OTHER MISCELLANEOUS ITEMS REQUIRED FOR THE OPERATION OF THE SYSTEM, WHETHER SPECIFICALLY CALLED OUT OR NOT. INSTALLATION SHALL FOLLOW ALL MANUFACTURER'S RECOMMENDATIONS. 2. CONTRACTOR SHALL REVIEW & BECOME FAMILIAR WITH THE WORK OF ALL TRADES CONTRACTOR SHALL REVIEW & BECOME FAMILIAR WITH THE WORK OF ALL TRADES FOR PURPOSES OF COORDINATION AND ROUTING. CONTRACTOR SHALL PROVIDE REQUIRED PLANNING, COORDINATION AND SEQUENCING OF ELECTRICAL INSTALLATION WITH BUILDING COMPONENTS AND OTHER TRADES. 3. ALL WORK SHALL COMPLY WITH THE 2020 VERSION OF THE NATIONAL ELECTRICAL ALL WORK SHALL COMPLY WITH THE 2020 VERSION OF THE NATIONAL ELECTRICAL CODE (NEC). WORKMANSHIP SHALL MEET OR EXCEED INDUSTRY STANDARDS. 4. BEFORE SUBMITTING SHOP DRAWINGS TO ENGINEER FOR REVIEW, ELECTRICAL BEFORE SUBMITTING SHOP DRAWINGS TO ENGINEER FOR REVIEW, ELECTRICAL CONTRACTOR SHALL REVIEW, STAMP, AND COORDINATE SUBMITTALS (SHOP DRAWINGS) WITH OTHER SUBMITTALS AND WITH THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. BY APPROVAL AND SUBMITTAL OF SHOP DRAWINGS, PRODUCT DATA, SAMPLES AND SIMILAR SUBMITTALS TO THE ENGINEER, THE CONTRACTOR REPRESENTS THAT IT HAS DETERMINED AND VERIFIED AND CHECKED THE INFORMATION WITHIN THE SUBMITTAL WITH THE REQUIREMENTS OF THE WORK AND THE CONTRACT DOCUMENTS. CONTRACTOR IS RESPONSIBLE FOR AND SHALL DETERMINE AND VERIFY ALL FIELD MEASUREMENTS, QUANTITIES, DIMENSIONS, AND INSTALLATION REQUIREMENTS. PROVIDE WRITTEN NOTICE ON SUBMITTAL OF ANY DEVIATIONS. THE CONTRACTOR SHALL NOT BE RELIEVED OF RESPONSIBILITY FOR DEVIATIONS FROM CONTRACT DOCUMENTS REQUIREMENTS BY THE ARCHITECT'S APPROVAL OF SHOP DRAWINGS OR OTHER SUBMITTALS UNLESS THE CONTRACTOR HAS SPECIFICALLY INFORMED THE ENGINEER IN WRITING OF SUCH DEVIATION AT THE TIME OF THE SUBMITTAL AND SUCH DEVIATION HAS BEEN APPROVED IN WRITING. ALL OPTIONS AND ACCESSORIES SHALL BE CLEARLY MARKED ON THE CUTSHEETS. 5. THE CITED EXAMPLES OF PRODUCTS ARE USED ONLY TO DENOTE THE QUALITY THE CITED EXAMPLES OF PRODUCTS ARE USED ONLY TO DENOTE THE QUALITY STANDARD OF PRODUCT DESIRED AND THEY DO NOT RESTRICT BIDDERS TO A SPECIFIC BRAND, MAKE, MANUFACTURER OR SPECIFIC NAME; THAT THEY ARE USED ONLY TO SET FORTH AND CONVEY TO BIDDERS THE GENERAL STYLE, TYPE, CHARACTER AND QUALITY OF PRODUCT DESIRED; AND THAT EQUIVALENT PRODUCTS WILL BE ACCEPTABLE. 6. PROTECT ALL NEW MATERIALS FROM THE WEATHER IN STORAGE TRAILERS OR PROVIDE PROTECT ALL NEW MATERIALS FROM THE WEATHER IN STORAGE TRAILERS OR PROVIDE SUITABLE COVERING. 7. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL DISCONNECTS, STARTERS, DEVICES AND ELECTRICAL CONTRACTOR SHALL PROVIDE ALL DISCONNECTS, STARTERS, DEVICES AND ELECTRICAL COMPONENTS UNLESS SPECIFICALLY NOTED AS PROVIDED BY OTHERS. COORDINATE LOCATION AND WIRING OF DEVICES WITH OTHER TRADES OR SUPPLIERS OF EQUIPMENT SUCH AS: ELEVATOR, FIRE PUMP AND FIRE PROTECTION PLANS, KITCHEN HOOD, KITCHEN COOLER, ETC. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL FIELD WIRING OF SPECIALTY ITEMS UNLESS NOTED OTHERWISE. 8. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL LINE AND LOAD SIDE WIRING INCLUDING ELECTRICAL CONTRACTOR SHALL PROVIDE ALL LINE AND LOAD SIDE WIRING INCLUDING ALL TERMINATIONS TO EQUIPMENT PROVIDED UNDER OTHER TRADES. POWER WIRING TO CONTROL DEVICES SHALL BE PROVIDED BY E.C.. INTERLOCK WIRING SHALL BE PROVIDED BY THE CONTRACTOR INSTALLING THE CONTROL DEVICE. 9. ALL WIRING, PANELBOARDS, DEVICES AND OTHER LIKE MATERIALS SHALL BE UL LISTED ALL WIRING, PANELBOARDS, DEVICES AND OTHER LIKE MATERIALS SHALL BE UL LISTED & LABELED. ALL MATERIALS SHALL MEET THE NEC FOR THE INTENDED USE AND INSTALLED IN ACCORDANCE WITH THE NEC. LOW VOLTAGE CONDUCTORS (600V OR LESS) 10. PROVIDE THHN/THWN COPPER WIRE (UL 83 LISTED). PROVIDE A MINIMUM WIRE SIZE PROVIDE THHN/THWN COPPER WIRE (UL 83 LISTED). PROVIDE A MINIMUM WIRE SIZE OF #12. ALL WIRE #8 AWG AND LARGER SHALL BE STRANDED, #10 AWG AND SMALLER SHALL BE SOLID. CONDUCTORS AND CONDUIT ON PLANS AND SCHEDULES REFLECT AMPACITIES PER NEC TABLE 310.16 75C RATING. CONTRACTOR SHALL VERIFY ALL TERMINATIONS, LUGS, ETC. ARE RATED FOR USE PER NEC 110.14(C). OTHERWISE PROVIDE CONDUCTOR AND CONDUIT SIZED PER LOWEST TEMPERATURE RATING OF ANY TERMINATION WITHIN A CIRCUIT. A SEPARATE INSULATED EQUIPMENT GROUNDING CONDUCTOR SHALL BE PROVIDED FOR ALL CIRCUITS. ALL EQUIPMENT FEEDERS SHALL BE RUN CONTINUOUS FROM THE BREAKER TO THE DISCONNECT SWITCH; SPLICES ARE NOT ALLOWED. WHERE MORE THAN THREE CURRENT-CARRYING CONDUCTORS ARE INSTALLED IN THE SAME RACEWAY, DERATE PER NEC TABLE 310.15(C)(1). #10 AWG #10 AWG SHALL BE USED FOR 20 AMPERE, 120 VOLT BRANCH CIRCUITS WITH A TOTAL INSTALLED LENGTH GREATER THAN 100 FEET. WHERE THE CONDUCTOR LENGTH FROM THE PANEL TO THE FIRST OUTLET ON A 120 VOLT CIRCUIT EXCEEDS 100 FEET, THE CONDUCTOR TO THE FIRST OUTLET SHALL NOT BE SMALLER THAN #10 AWG. WHERE WHERE WHERE THE CONDUCTOR LENGTH IS GREATER THAN 150 FEET, THEN USE #8 AWG, AND IF GREATER THAN 250 FEET, USE #6 AWG. 11. COLOR CODING OF WIRE SHALL BE AS FOLLOWS: COLOR CODING OF WIRE SHALL BE AS FOLLOWS: 208/120V PHASE A BLACK PHASE A BLACK BLACK PHASE B RED RED PHASE C BLUE BLUE NEUTRAL WHITE WHITE EQ. GROUND GREEN GREEN 12. PROVIDE LABELS ON ALL RECEPTACLES IDENTIFYING PANEL AND CIRCUIT NUMBER. PROVIDE LABELS ON ALL RECEPTACLES IDENTIFYING PANEL AND CIRCUIT NUMBER. LABELS SHALL BE BRADY CLEAR POLYESTER 1"W X 0.375"H OR PANDUIT EQUAL, WITH BLACK LETTERING. MARK ALL JUNCTION BOXES ABOVE CEILING INDICATING PANEL AND CIRCUIT NUMBER USING PERMANENT MARKER. PROVIDE PHENOLIC LABEL ON EXTERIOR BOXES WITH EQUIPMENT DESCRIPTION, AND PANEL AND CIRCUIT NUMBER. BOXES SHALL NOT BE INSTALLED IN AN INACCESSIBLE LOCATION. RACEWAYS AND BOXES 13. PROVIDE MINIMUM 3/4" CONDUIT FOR ALL WIRING. ALL RACEWAYS SHALL BE PROVIDE MINIMUM 3/4" CONDUIT FOR ALL WIRING. ALL RACEWAYS SHALL BE INSTALLED WITHIN WALLS, INCLUDING BLOCK, UNLESS NOTED OTHERWISE. EMT OR RIGID SHALL BE USED WHERE EXPOSED TO PHYSICAL DAMAGE. CONDUIT ABOVE GRADE SHALL BE STEEL. EMT SHALL NOT BE USED IN DIRECT CONTACT WITH THE EARTH, EXTERIOR LOCATIONS, OR WHERE EXPOSED TO SEVERE PHYSICAL DAMAGE. FITTINGS ON EMT CONDUIT SHALL BE COMPRESSION TYPE. FITTINGS ON IMC OR RGS SHALL BE THREADED. MOTOR CONNECTIONS SHALL BE MADE WITH FMC, MIN. 18" LONG AND MAX 36". USE PVC JACKETED FLEXIBLE LIQUID TIGHT CONDUIT TYPE UA FOR CONNECTIONS IN WET LOCATIONS. LOCATE JUNCTION AND PULL BOXES SUCH THAT THEY REMAIN ACCESSIBLE AFTER ALL CONSTRUCTION WORK IS COMPLETE. 14. ALL EMPTY RACEWAYS SHALL BE PROVIDED WITH PULL STRING. INSTALL NO MORE ALL EMPTY RACEWAYS SHALL BE PROVIDED WITH PULL STRING. INSTALL NO MORE INSTALL NO MORE THAN EQUIVALENT OF THREE 90-DEGREE BENDS IN CONDUIT RUN. SUPPORT WITHIN 12 INCH OF CHANGES IN DIRECTION. MAKE BENDS IN RACEWAY USING LARGE-RADIUS PREFORMED ELLS EXCEPT FOR PARALLEL BENDS. FIELD BENDING MUST BE IN ACCORDANCE WITH NFPA 70 MINIMUM RADII REQUIREMENTS. PROVIDE ONLY EQUIPMENT SPECIFICALLY DESIGNED FOR MATERIAL AND SIZE INVOLVED. SUPPORT CONDUIT WITHIN 12 INCH OF ENCLOSURES TO WHICH ATTACHED. SEAL SERVICE RACEWAYS ENTERING A . SEAL SERVICE RACEWAYS ENTERING A BUILDING FROM AN UNDERGROUND SYSTEM PER NEC 230.8 AND 300.5(G). WHERE CONCENTRIC, ECCENTRIC OR OVER-SIZED KNOCKOUTS ARE ENCOUNTERED, A GROUNDING-TYPE INSULATED BUSHING SHALL BE PROVIDED FOR CIRCUITS OVER 250V PER NEC 250.97. 15. PROVIDE ONE-INCH CONDUITS EXTENDING TO CABLE TRAY (WHERE PROVIDED) OR PROVIDE ONE-INCH CONDUITS EXTENDING TO CABLE TRAY (WHERE PROVIDED) OR ABOVE CORRIDOR CEILING FOR ALL TELEPHONE AND DATA OUTLETS SHOWN ON PLANS. PROVIDE PROTECTIVE BUSHINGS ON ENDS OF CONDUIT. SEE PLAN DETAILS FOR CABLE REQUIREMENTS AT EACH LOCATION. PROVIDE 12 INCH SERVICE LOOP ABOVE EACH OUTLET. 16. PROVIDE 3/4-INCH EMPTY CONDUITS TERMINATING ABOVE THE CEILING FOR ALL HVAC PROVIDE 3/4-INCH EMPTY CONDUITS TERMINATING ABOVE THE CEILING FOR ALL HVAC THERMOSTATS. JUNCTION BOXES SHALL MATCH ORIENTATION OF THERMOSTATS PROVIDED BY M.C.. MOUNT JUNCTION BOXES 48-INCHES A.F.F. UNLESS NOTED OTHERWISE. PROVIDE PROTECTIVE BUSHINGS ON ENDS OF CONDUIT. PANELBOARDS 17. PANELBOARDS FOR SERVICE ENTRANCE SHALL BE SERVICE ENTRANCE RATED. PROVIDE PANELBOARDS FOR SERVICE ENTRANCE SHALL BE SERVICE ENTRANCE RATED. PROVIDE NEMA 3R PANELBOARDS WHERE LOCATED OUTSIDE. PROVIDE COPPER NEUTRAL AND GROUNDING BARS IN ALL PANELBOARDS UNLESS NOTED OTHERWISE (ALUMINUM IS NOT ALLOWED). GROUND ALL SERVICE ENTRANCE PANELS AND RACEWAYS (BONDING BUSHINGS) IN ACCORDANCE WITH THE NEC. PROVIDE BOLT-IN BREAKERS UNLESS NOTED OTHERWISE. PROVIDE A MINIMUM OF THREE SPARE 3/4" CONDUITS TO ABOVE CEILING FOR ALL FLUSH MOUNTED PANELBOARDS. PANELS SHALL BE FULLY RATED FOR SHORT CIRCUIT CURRENT, SERIES RATINGS ARE NOT ALLOWED.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .