Architectural Drawings - Stilley Station.pdf
PDF 2 MB Posted
- Solicitation number
- 475-SW-FY26-004
- Issued by
- Beaufort County, North Carolina
About this file
Stilley Station Attendant Building - Architectural Drawings Summary
This document comprises architectural drawings and specifications for the Stilley Station Attendant Building, a state and local construction project in Beaufort County, North Carolina, prepared by Beacon Architecture + Design, P.L.L.C. in coordination with Coastal Engineering, PLLC and RPA Engineering, P.A. The project involves construction of a single-story, 520-square-foot office building designed for business use with an occupancy load of six persons. The building includes an open office area, an ADA-compliant toilet room, a storage room, and a kitchenette. Construction specifications address structural design per 2018 North Carolina Building Code requirements, with provisions for standing-seam metal roofing rated for 130 mph wind velocity, vinyl siding with board-and-batten details, and ADA-compliant features including threshold treatments, grab bars, and accessible fixtures. The drawings were issued for bid on March 30, 2026, and include comprehensive details for mechanical systems (split-system heat pump with 16.5 MBH cooling capacity and 12.5 MBH heating capacity), plumbing fixtures (one water closet, one lavatory, one kitchen sink), electrical systems with 200-amp service, and complete finish specifications.
The specifications establish construction requirements across all divisions including concrete slab foundation with monolithic pour and 6-mil vapor barrier, wood-frame construction with R-15 exterior wall insulation and R-38 attic insulation, gypsum wallboard interior finishes with epoxy paint, sealed concrete flooring, vinyl wall base, and stainless steel plumbing fixtures. The general contractor bears responsibility for obtaining all permits, coordinating work among trades, and providing submittals for architect approval prior to material procurement. A 12-month warranty is required on all workmanship and materials from the date of substantial completion. The specifications reference compliance with applicable North Carolina codes, ASHRAE standards for mechanical systems, and NFPA standards for electrical work. All project coordination shall occur with Coastal Engineering, PLLC as the prime engineer, with specific requirements for third-party inspection, testing, and certification documented in supporting schedules and engineering drawings referenced throughout the specification set.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CODE ANALYSIS
GENERAL NOTES
2018 NORTH CAROLINA BUILDING CODEYEAR EDITION OF CODE
PROJECT INFO NAME OF PROJECT
ADDRESS
PROPOSED USE
OWNER REPRESENATIVE
CODE ENFORCEMENT
LEAD DESIGN PROFESSIONAL BEACON ARCHITECTURE + DESIGN, P.L.L.C.
DESIGNER
ARCHITECTURAL
CIVIL
ELECTRICAL
FIRE ALARM
PLUMBING
MECHANICAL
STRUCTURAL
CONSTRUCTION TYPE
SPRINKLERS
STANDPIPES
FIRE DISTRICT
BUILDING HEIGHT
MEZZANINE
HIGH RISE
GROSS BUILDING AREA
ALLOWABLE AREA
TYPE OF CONSTRUCTION
ALLOWABLE BUILDING HEIGHT
ACTUAL BUILDING HEIGHT
ALLOWABLE HEIGHT
FIRE SEPARATION DISTANCE
STRUCTURAL FRAME
BEARING WALLS
EXTERIOR
INTERIOR
NON-BEARING WALLS
EXTERIOR
INTERIOR
ROOF
FIRE PROTECTION
REQUIREMENTS
EMERGENCY LIGHTING
EXIT SIGNS
FIRE ALARM
SMOKE DETECTION SYSTEMS
PANIC HARDWARE
LIFE SAFETY SYSTEM
REQUIREMENTS
BUILDING DATA
PRIMARY OCCUPANCY
DESCRIPTION AND USE
ALLOWABLE AREA/STORY*
ACTUAL BUILDING AREA
NOT REQUIREDSPRINKLERS
ELEVATOR NOT REQUIRED- BUILDING IS ONE STORY WITH ADA THRESHOLDS
AT DOORS AND SLOPED ENTRY.
ELEVATOR
REQUIREMENTS
ATTENDANT OFFICE BUILDING
OFFICE - BUSINESS
GARRETT & MOORE ASSOCIATES
BEAUFORT COUNTY
ATTENDANT OFFICE
BUSINESS
1/ 9,000 SF
1/ 520 SF
VB- EXISTING TO REMAIN UNCHANGED
NO
NO
NO
EXISTING TO REMAIN UNCHANGED
NO
NO
520 SF
VB
40 FEET
+/- 14'-0"
30' MIN.- SEE CIVIL SITE PLANS
0 HRS
0 HRS
0 HRS
0 HRS
0 HRS
0 HRS
REQUIRED
REQUIRED
NOT REQUIRED
NOT REQUIRED
NOT REQUIRED
PLUMBING FIXTURE REQUIREMENTS
WATERCLOSETS
MALE FEMALEOCCUPANCY
LAVATORIES
MALE FEMALE
BUSINESS (REQUIRED)
* NO SEPARATE FIXTURES REQUIRED FOR LESS THAN 26 OCCUPANTS. SEE SECTION 2902.2.2.
** DRINKING FOUNTAINS NOT REQUIRED FOR LESS THAN 16 OCCUPANTS. SEE SECTION 2902.6.
*** SERVICE SINKS NOT REQUIRED FOR LESS THAN 26 OCCUPANTS. SEE TABLE 2902.1, FOOTNOTE "O".
DRINKING FOUNTAINS
REGULAR ACCESSIBLE
PROVIDED 1*
URINALS
MALE
N/A N/A
1 (1:25) 1*
1 (1:40) 0 (1:100) 0**
LIST OF DRAWINGS
TITLE SHEET
A1.1
T1.1
BUILDING PLANS
BUILDING SECTION
SYMBOLS
ELEVATION LINE
WINDOW/DOOR SYMBOL
A4.1
A4.1
BUILDING DETAIL
A3.1
ELEVATION SYMBOL
1 KEY BUBBLE
CODE/ ADA INFORMATION
ELECTRICAL DEVICE AND FIXTURE MOUNTING HEIGHTS- ALL ADA FIXTURES SHALL MEET ANSI A117.1 REQUIREMENTS.
" M
IN
. K
NE
E
SP
AC
E
CLEAR
KNEE/TOE
SPACE
6"
MAX.
9" MI
N.
8"
MIN.
" M
AX
DRINKING FOUNTAINS (HIGH/LOW JOINED UNIT)
*MEASURED FROM FINISHED FLOOR
TO SPOUT OUTLET HEIGHT
COVER HOT
WATER SUPPLY
& DRAIN LINES
W/ INSULATION
SECTION ELEVATION
15"
MIN.
" M
AX
. T
O
BO
TT
OM
O F
MI
RR
OR
G
LA
SS
(N
OT
F
RA
ME
15"
MIN.
15"
MIN.
CL
LAVATORY
ELEVATION ELEVATION
MIRRORMIRROR
MI
N.
TOILET PAPER
DISPENSER
(TYPE DEPENDANT)
SANITARY NAPKIN
DISPOSAL
" M
IN
. 48
" M
AX
PAPER
TOWEL
DISPENSER
" M
AX
SOAP
DISPENSER
" M
AX
HAND
DRYER
" M
AX
. T
O
TO
W
EL
S
LO
T
" M
AX
T O
W
AS
TE
PAPER
TOWEL
WASTE
RECEPTACLE
PAPER
TOWEL
STORAGE
PAPER TOWEL &
WASTE RECEPTACLE
" M
AX
TOWEL, ROBE,
PURSE HOOK
TOWEL BAR
" M
AX
SANITARY
NAPKIN
DISPENSER
MATERIALPRODUCTTRADENAMEMODELNUMBER
6" MAX. 36" MIN.
MA
X.
" M
IN
16"-18"
GRABBAR
WATERCLOSET
CLEAR FLOOR SPACE AT WATERCLOSET
(ARROWS DENOTE DIRECTION OF APPROACH)
CL
" M
IN
PARTITION
PLAN
30" MIN
CLEAR
" M
IN
.8"
MIN.
9" MI
N.
6"
MAX.
17" - 25"
MODELNUMBERTRADENAMEPRODUCTMATERIAL WCMODELNUMBER TRADENAME PRODUCT MATERIAL
WATERCLOSET
ELEVATIONS
GRABBAR
39"-41"
" M
IN
"-1
9"
TO
T
OP
OF
S
EA
T33
"-3 6"
42" MIN.
12"
MAX.
"-4
1"
16"-18"'
TO CL.
36" MIN.
"-3
6"
BI-LEVEL DRINKING
FOUNTAIN
W/ BOTTLE FILLER
" M
AX
9" M
IN
A.
F.
F.
54" MIN.
" M
IN
60" MIN.
16"-18"
CL
60" MIN TO ADJ.
PLUMBING FIXTURE
VERTICAL GRABBAR
SEE ELEV. FOR DIMS.
1 14"-2" O.D. 1 12"
TOILET GRAB-BAR
1 2"
MA
X.
ALUM. THRESHOLD
ADA COMPLIANT
LOW-PROFILE
DOOR SWEEP
MAX. 12" FLOOR
FINISH @ SILL
DOOR AS SCHED.
ADA THRESHOLD
1 12" - 2" DIA. WOOD/METAL ADA HANDRAIL
COORD. SPEC. W/ARCH. IN THE FIELD
1 12"
"-3
8" M
AX
. T
O W
AL
KI
NG
S
UR
FA
CE
(3
6" T
YP
IC
AL
U
.O .N
48" MIN.WIDTH
BETWEEN HANDRAILS
1"X RAIL MOUNTING BOARD
GUARDRAIL AS REQUIRED
PAINTED HARDWOOD
CAP AND REVEAL
1/8"
3/8
3/4
GU
AR
DR
AI
L 4 2"
A .F
.F
8" GWB
1 12" - 2" DIA. WOOD/METAL
ADA HANDRAIL COORD. SPEC.
W/ARCH. IN THE FIELD
1 12" -2" DIA. WOOD/METAL ADA HANDRAIL
COORD. SPEC. W/ARCH. IN THE FIELD
1 1/2"
"-3
8" M
AX
. T
O W
AL
KI
NG
S
UR
FA
CE
(3
6" T
YP
IC
AL
U
.O .N
"-3
8" M
AX
. T
O W
AL
KI
NG
S
UR
FA
CE
(3
6" T
YP
IC
AL
U
.O .N
1 1/2"
48" MIN.WIDTH
BETWEEN HANDRAILS
48" MIN.WIDTH
BETWEEN HANDRAILS
ATTENDANT BUILDING
BEAUFORT COUNTY, NORTH CAROLINA
A1.2 ROOF PLAN & DETAILS
FIRM
BEACON ARCHITECTURE + DESIGN, P.L.L.C.
GARRETT & MOORE, P.E.
COASTAL ENGINEERING, PLLC
N/A
COASTAL ENGINEERING, PLLC
COASTAL ENGINEERING, PLLC
RPA ENGINEERING, P.A.
NAME
CHRISTOPHER NASON
CRAIG M. FORTNER
RICH KLEIN
N/A
RICH KLEIN
RICH KLEIN
MARK ROY, PE
LICENSE #
51585 029929 027968 N/A 027968 027968 032628
TELEPHONE #
(252) 441-6767
(919) 792-1900
(757) 563-9027 N/A
(757) 563-9027
(757) 563-9027
(252) 321-6027
ACCESSIBLE PARKING
ELECTRICAL SUMMARY
ENERGY SUMMARY:
SEE MECHANICAL ENGINEERING DRAWINGS
SEE CIVIL ENGINEERING DRAWINGS
ENERGY/MECHANICAL SUMMARY
STRUCTURAL DESIGN:
SEE STRUCTURAL ENGINEERING DRAWINGS
* OPEN AREA INCREASE DUE TO FRONTAGE NOT REQUIRED TO COMPLY
5"
MAX.
6"
MAX.
42" MIN.
FLUSH
CONTROL
" M
AX
" M
AX
FLUSH CONTROL
(OPEN SIDE)
MODELNUMBERTRADENAMEPRODUCTMATERIAL
PROTRUDING
DISPENSERS
" M
IN
1 1 2"
MI
N.
42" MAX.
24" MIN.CL
7"-9"
" M
IN
" M
AX
TOILET PAPER
EXCEPTION 602.7.1
25"
MAX.
11"
MIN.
KNEE & TOE CLEARANCE SPACE AT LAVATORY
" M
AX
" M
IN
" M
AX
DIAPER CHANGING
STATION
ADA COMPLIANT FIRE EXTINGUISHER
IF CABINET IS A SEMI-RECESSED MODEL IT MAY NOT PROTRUDE
MORE THAN 4" INTO PATH OF EGRESS. ALL EXTINGUISHERS SHALL BE
LOCATED ALONG NORMAL PATHS OF TRAVEL, AVAILABLE AND
ACCESSIBLE TO OCCUPANTS WHEN EVACUATING. PROVIDE SIGNAGE
AS REQUIRED.
FIRE EXTINGUISHER MOUNTING HEIGHTS
" M
IN
CL
EA
R
FL
OO
R
SP
AC
E
30" MIN.
CLEAR FLOOR
SPACE
30" CLR. MIN.
FOR FORWARD
APPROACH
" M
AX
CLEAR
SPACE
ELEVATION PLAN
" M
AX
. T
O
OP
ER
AB
LE
P
AR
TS
4" MA
X.
" M
IN
1. THE ARCHITECT SHALL NOT BE RESPONSIBLE FOR ANY ERROR, OMISSION, DEFECT OR DEFICIENCY IN THE CONTRACT DOCUMENTS ("ERROR") PREPARED BY THE ARCHITECT OR ITS CONSULTANTS WHICH IN ANY WAY IMPACTS THE SCHEDULE OF THE PROJECT, RESULTS IN A LACK OF COORDINATION AMONG THE CONTRACT DOCUMENTS, DELAYS THE COMPLETION OF THE PROJECT OR WHICH IN ANY OTHER WAY CAUSES ANY DAMAGE OR LOSS TO THE OWNER, CONTRACTOR, SUBCONTRACTORS, OR OTHER ENTITY INVOLVED IN THE PROJECT UNLESS: (1) THE ARCHITECT IS PROMPTLY NOTIFIED OF SUCH ERROR, IN ANY EVENT WITHIN 14 DAYS OF THE DATE SUCH ERROR WAS DISCOVERED OR COULD REASONABLY HAVE BEEN DISCOVERED; AND (2) THE ARCHITECT IS GIVEN OPPORTUNITY AT THE TIME OF DISCOVERY TO ADDRESS SUCH ERROR, AND IF APPROPRIATE, TAKE SUCH STEPS AS ARE NECESSARY TO CORRECT AND RESOLVE IT. FAILURE TO COMPLY WITH THE PROVISIONS OF THIS PARAGRAPH SHALL CONSTITUTE A WAIVER OF ANY CLAIM FOR DAMAGES, OR A RIGHT TO OFFSET AGAINST THE ARCHITECT BY OWNER, CONTRACTOR OR OTHERS AND SHALL IN NO EVENT CAUSE OR ALLOW A REDUCTION IN THE FEES OTHERWISE DUE THE ARCHITECT FOR SERVICES PROVIDED ON THE PROJECT.
2. THE ARCHITECT IS NOT RESPONSIBLE FOR ANY DAMAGES CAUSED BY OMISSIONS OR INACCURACIES OF SITE INFORMATION. INCLUDING BUT NOT LIMITED TO EASEMENTS, SETBACKS, METES AND BOUNDS, TITLE OWNERSHIP, FLOOD ZONE DESIGNATIONS AND CAMA REQUIREMENTS, PROVIDED BY THE CLIENT, TAX MAPS, SURVEYORS AND/OR
ENGINEERS.
3. ALL PARTIES ACKNOWLEDGE AND AGREE THAT ALL DESIGNS ARE THE SOLE PROPERTY OF THE ARCHITECT. THIS AGREEMENT IS FOR A SINGLE LICENSED USE OF PLANS.
ANY USE OF PLANS, OTHER THAN THE LIMITED LICENCE PROVIDED IN THIS PARAGRAPH IS NOT PERMITTED WITHOUT PRIOR WRITTEN CONSENT OF ARCHITECT. CLIENT SHALL PAY ARCHITECT FOR ANY REVISION WORK MADE TO DRAWINGS FOR REUSE AT AN HOURLY RATE DETERMINED BY THE ARCHITECT. ARCHITECT SHALL HAVE THE RIGHT TO INCLUDE PHOTOGRAPHIC OR ARTISTIC REPRESENTATIONS OF THE PROJECT AMONG THE ARCHITECT'S PROMOTIONAL AND PROFESSIONAL MATERIALS (INCLUDING WITHOUT
LIMITATION ARCHITECT'S WEBSITE).
4. THE ARCHITECT IS NOT RESPONSIBLE FOR MEANS, METHODS OR TECHNIQUES IN THE CONSTRUCTION OF THIS PROJECT.
5. GENERAL CONTRACTOR IS SOLELY RESPONSIBLE FOR THE PROPER INSTALLATION OF ALL INSULATION. INSULATION MUST BE CONTINUOUS AT THE BUILDING ENVELOPE, G.C. TO BLOCK AS REQ'D FOR INSTALLATION. THE ARCHITECT RECOMMENDS A WHOLE BUILDING BLOWER DOOR TEST TO BE PERFORMED AS WELL AS THERMAL IMAGING TO ASSURE PROPER SUBCONTRACTOR INSTALLATION PRIOR TO COMPLETION AND THE TEST RESULTS PROVIDED TO THE ARCHITECT/OWNER.
6. THE G.C. SHALL PROVIDE SUBMITTALS TO THE ARCHITECT FOR REVIEW. SUBMITTALS ARE AN ESSENTIAL PART OF THE CONSTRUCTION PROCESS. IF THE CONTRACTOR ELECTS NOT PROVIDE SUBMITTALS THEN HE/SHE ASSUMES AS RESPONSIBILITY FOR ENTIRETY OF THE PROJECT.
A2.1 EXTERIOR ELEVATIONS
A3.1 BUILDING SECTION & SCHEDULES
NUMBER AND ARRANGEMENT OF EXITS- ONLY ONE EXIT REQUIRED*
EXIT REQUIREMENTS
MIN. NUMBER OF EXITS
REQUIRED SHOWN
FLOOR, ROOM OR
SPACE DESIGNATION
TRAVEL DISTANCE
ALLOWABLE ACTUAL
1 1OPEN OFFICE
EXIT WIDTH (1 STORY)
FLOOR, ROOM OR SPACE
DESIGNATION
(a)
AREA
(b)
AREA/OC. OCC.S
REQUIRED
WIDTH
ACTUAL
WIDTH
TOTAL OCCUPANTS 6 ACTUAL
ARRANGEMENT MEANS OF EGRESS
REQUIRED DISTANCE ACTUAL DISTANCE
34" CLR.100 G 5.2
100' 19'-5" MAX
EGRESS WIDTH
(IN.OCC.)
1 1ADA TOILET ROOM 26'-0" MAX
1.04"0.2 2"
1 1STORAGE ROOM 11'-0" MAX
N/A N/A
N/A N/A
100' 100'
N/A N/A
*FOR SPACES/BUILDINGS WITH LESS THAN 49 OCCUPANTS (SEE TABLE 1006.2.1)
BUSINESS USE
ARCHITECTURAL DRAWINGS
PLUMBING DRAWINGS
P0.1
FLOOR PLAN & RISERSP2.1
PLUMBING SPECIFICATIONSP7.1
SPECIFICATIONS, LEGEND, ABBR.,
DETAILS, & SCHEDULE
MECHANICAL DRAWINGS
GEN. NOTES, LEGEND AND ABBREVIATIONSM0.1
FLOOR PLAN NEW WORKM2.1
MECHANICAL SCHEDULESM6.1
MECHANICAL SPECIFICATION M7.1
ELECTRICAL DRAWINGS
E0.1
E2.2
E2.1
E7.1
E6.1
GENERAL NOTES, LEGEND AND
ABBREVIATIONS
FLOOR PLAN - POWER AND SPECIAL
SYSTEMS
FLOOR PLAN - LIGHTING
SCHEDULE, RISER DIAGRAM, AND
DETAIL
ELECTRICAL SPECIFICATIONS
SPECIFICATIONST1.2
SEE ELECTRICAL ENGINEERING DRAWINGS
SEE MECHANICAL ENGINEERING DRAWINGS
SERVICE SINKS
0***
C
SHEET:
STAMP:
SCALE:
DATE:
DRAWN BY:
ARCHITECTURE + DESIGN, P.L.L.C.
P.O. BOX 1827
KITTY HAWK, NC 27949
PH: (252) 441-6767, FAX (252) 261-6045
BEACON
DRAWING NAME:
ATTENDANT
Beaufort County North Carolina
BUILDING
PROJECT NAME:
CN
2406 Princess Anne Road
Virginia Beach, VA 23456 Phone (757) 563-9027
Facsimile(757) 563-9028
Suite 200
COASTAL
E N G I N E E R I N G
PME ENGINEER:
2026 BEACON ARCHITECTURE + DESIGN
P.L.L.C.- ALL RIGHTS RESERVED
3 / 30 / 26
REVISIONS: DATE:
STRUCTURAL ENGINEER:
RPA ENGINEERING, PE
102 REGENCY BLVD., SUITE A1
GREENVILLE, NORTH CAROLINA
PH: (252) 321-6027
Stilley Station
ISSUED FOR
BID
ISSUE FOR BID
3 / 30 / 26
3 / 30 / 26
T1.1
TITLE SHEETSTILLEY STATION ROAD, BEAUFORT COUNTY, NC
DIVISION 6: WOOD & PLASTICS
GENERAL CONDITIONS (00700):
WORK INCLUDED:
1. CONFORM WORK TO THE CONTRACT DOCUMENTS WHICH INCLUDE THE OWNER/CONTRACTOR AGREEMENT.
THE DRAWINGS, AND ALL ADDENDA AND MODIFICATIONS ISSUED BY THE ARCHITECT.
2. THE GENERAL CONDITIONS OF THE CONTRACT IS THE AMERICAN INSTITUTE OF ARCHITECTS' AIA DOCUMENT A201-2017, " GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION", WHICH IS MADE A PART OF THE CONTRACT DOCUMENTS AS IF BOUND HEREIN. THE ARCHITECT WILL PROVIDE A SINGLE COPY OF DOCUMENT UPON REQUEST.
3. THE ARCHITECT IS NOT RESPONSIBLE FOR MEANS METHODS OR TECHNIQUES IN THE CONSTRUCTION OF THE PROJECT.
DIVISION 0: GENERAL CONDITIONS
SUBMITTALS (01340):
PROCEDURES:
1. PRIOR TO COMMENCING SUBSTANTIAL PORTIONS OF THE WORK, PREPARE A MASTER SUBMITTAL LOG SHOWING EACH REQUIRED SUBMITTAL AND SPECIFICATION SECTION NUMBER, THE PROPOSED SCHEDULE AND SEQUENCING OF THE SUBMITTALS AND EACH AFFECTED CONTRACTOR. MAINTAIN THE LOG CURRENT WITH THE PROGRESS OF THE WORK.
PROVIDE A COPY OF THE INITIAL AND UPDATED LOG TO THE ARCHITECT.
2. REVIEW SUBMITTALS AND INDICATE RESULTS OF REVIEW PRIOR TO SUBMITTING TO ARCHITECT.
3. AFTER REVIEW OF SUBMITTAL, REVISE AND RESUBMIT IF SO INDICATED; IDENTIFY CHANGES MADE SINCE PREVIOUS
SUBMITTAL.
4. DISTRIBUTE COPIES OF REVIEWED SUBMITTALS TO CONCERNED CONTRACTORS INSTRUCT RECIPIENTS TO PROMPTLY REPORT
ANY INABILITY TO COMPLY WITH PROVISIONS.
5. MAKE SUBMITTALS FAR ENOUGH IN ADVANCE OF SCHEDULED INSTALLATION DATES TO PROVIDE TIME REQUIRED FOR REVIEWS, FOR SECURING OF NECESSARY APPROVALS, FOR POSSIBLE REVISIONS AND RESUBMITTALS, AND FOR PLACING
ORDERS AND SECURING DELIVERY.
6. SUBMITTALS PROVIDED FOR WORK AND FOR WHICH NO REQUIREMENT FOR SUBMITTAL IS STATED IN THE DRAWINGS OR
SPECIFICATIONS WILL BE RETURNED WITHOUT REVIEW.
SHOP DRAWINGS:
1. SUBMIT THREE REPRODUCIBLE COPIES OF SHOP DRAWINGS (8 12" X 11" MINIMUM SIZE SHEETS)
2. ELECTRONIC EQUIVALENT SHOP DRAWINGS WILL ALSO BE ACCEPTABLE
SAMPLES:
1. SUBMIT A REASONABLE RANGE OF MANUFACTURER'S STANDARD COLORS, TEXTURES, ETC. FOR SELECTION WHERE SPECIFIC PRODUCT REQUIREMENTS HAVE NOT BEEN STATED OR WHERE SUBSTITUTIONS ARE PROPOSED.
2. SUBMIT SAMPLES TO ILLUSTRATE FUNCTIONAL AND SIGHT-EXPOSED CHARACTERISTICS OF THE PRODUCT, WITH
INTEGRAL PARTS AND ATTACHMENT DEVICES.
3. INCLUDE IDENTIFICATION ON EACH SAMPLE, GIVING FULL INFORMATION.
4. SUBMIT THREE (3) SETS OF EACH PRODUCT FOR THE ARCHITECT PLUS ADDITIONAL SETS AS REQUIRED BY THE
CONTRACTOR.
SUBSTITUTIONS (01630):
REQUESTS FOR SUBSTITUTIONS:
1. SUBMIT SEPARATE REQUESTS FOR EACH PRODUCT AND SUPPORT EACH REQUEST WITH:
A. PRODUCT IDENTIFICATION
B. MANUFACTURER'S LITERATURE
C. SAMPLES AS APPLICABLE
D. NAME AND ADDRESS OF SIMILAR PROJECTS ON WHICH PRODUCT HAS BEEN USED AN DATE OF
INSTALLATION.
2. REASON FOR SUBSTITUTION.
3. ITEMIZE A COMPARISON OF THE PROPOSED SUBSTITUTION WITH PRODUCT SPECIFIED AND LIST SIGNIFICANT
VARIATIONS.
4. SUBMIT DATA RELATING TO CHANGES IN CONSTRUCTION SCHEDULE.
5. INCLUDE ACCURATE COST DATA COMPARING PROPOSED SUBSTITUTION WITH PRODUCT AND THE AMOUNT OF
ANY NET CHANGE IN THE CONTRACT PRICE.
6. SUBSTITUTIONS WILL NOT BE CONSIDERED WHEN:
A. THEY ARE INDICATED OR IMPLIED ON SUBMITTALS WITHOUT A FORMAL REQUEST.
B. ACCEPTANCE WILL REQUIRE SUBSTANTIAL REVISION OF DRAWINGS AND SPECIFICATIONS.
7. DO NOT ORDER OR PROVIDE SUBSTITUTE PRODUCTS WITHOUT APPROVAL.
8. BURDEN OF PROOF OF MERIT OF PROPOSED SUBSTITUTION IS THE RESPONSIBILITY OF THE CONTRACTOR.
DIVISION 1: GENERAL REQUIREMENTS
DIVISION 2-5: SITEWORK
(SEE CIVIL ENGINEERING DRAWINGS, TYPICAL)
ROUGH CARPENTRY (06100):
WORK INCLUDED:
1. WOOD BLOCKING IN WALLS AND ABOVE CEILINGS.
2. PLYWOOD PANEL BOARDS.
3. SUB FLOORING
4. EXTERIOR SHEATHING
5. ROOF SHEATHING- BOTH PLYWOOD AS WELL AS CORRUGATED METAL ROOF DECKING
6. FIRE-RETARDANT TREATMENT
7. FOR STRUCTURAL SHEATHING SEE STRUCTURAL DRAWINGS.
SEE STRUCTURAL SPECIFICATIONS, TYP.
DIVISION 4: MASONRY
DIVISION 3: CONCRETE
DIVISION 5: ARCHITECTURAL METALS
SEE STRUCTURAL SPECIFICATIONS, TYP.
FOR THIRD-PARTY GEOTECHNICAL TESTING RELATED TO THE BUILDING, SEE SCHEDULE OF SPECIAL INSPECTION DOCUMENT
PROVIDED BY THE STRUCTURAL ENGINEER.
EXECUTION:
1. CORRELATE LOCATION OF FURRING, NAILERS, BLOCKING, GROUNDS AND SIMILIAR SUPPORTS SO THAT
ATTACHED WORK WILL COMPLY WITH DESIGN REQUIREMENTS AND BE PROPERLY LOCATED.
2. CONSTRUCT MEMBERS OF CONTINUOUS PIECES OF LONGEST POSSIBLE LENGTHS.
3. FIT CARPENTRY WORK TO OTHER WORK. SCRIBE AND COPE AS REQUIRED FOR ACCURATE FIT.
4. SHIM WITH METAL OR SLATE FOR BEARING ON CONCRETE AND MASONRY SUBSTRATES.
5. SECURELY ATTACH CARPENTRY WORK TO SUBSTRATES BY ANCHORING AND FASTENING AS REQ'D.
BY RECOGNIZED STANDARDS.
A. PROVIDE WASHERS UNDER BOLT HEADS AND NUTS IN CONTACT WITH WOOD.
B. NAIL PLYWOOD TO COMPLY WITH RECOMMENDATIONS OF THE AMERICAN PLYWOOD
ASSOCIATION.
6. WOOD GROUNDS, NAILERS, BLOCKING AND FURRING:
NOT APPLICABLE
DIVISION 7: THERMAL AND MOISTURE PROTECTION
INSULATION (07210):
1. ALL BLANKET INSULATION (BATTS): CONFORM TO FEDERAL SPECIFICATIONS HH-I-521, TYPE III.
2. FOR CEILINGS AND ATTIC SPACES USE R-38 PAPER FACED GLASS FIBER INSULATION OR EQUIV. POLY ISO SPRAY FOAM
PRODUCT.
3. FOR EXTERIOR WALLS AND IN BETWEEN STORAGE/OFFICE USE R-15 PAPER FACED GLASS FIBER INSULATION OR
EQUIV. POLY ISO SPRAY FOAM PRODUCT. FOR ALL OTHER WALLS USE R-13 MIN.
4. 3 12" THICK MIN. ACOUSTIC INSULATION AT INTERIOR WALLS TO FILL WALL CAVITY, MEETING ASTM C 665 WITH A NRC 1.05.
VAPOR BARRIERS/WEATHER RESISTIVE BARRIER (07200):
1. FOR THE BUILDING ROOF, G.C. TO PROVIDE SYNTHETIC ROOF UNDERLAYMENT TO MEET LOCAL WIND CODES AS WELL AS ASTM D226, ASTM D 4869, AC 188, ICC-ED ESR-4055 FBC APPROVED FL21895, ASTM E108, ASTM D5034, ASTM D4533, AND ASTM D4869. 30 YEAR WARRANTY AND RATED FOR 180 DAY (MIN) UV EXPOSURE. PRODUCT IS TO BE COMPATIBLE
WITH ROOF MFG SO AS NOT TO VOID ANY WARRANTIES.
2. FOR THE WALLS, G.C TO PROVIDE VAPOR BARRIER AT EXTERIOR WOOD FRAMED WALLS TO MEET OR EXCEED NORTH CAROLINA ENERGY CODES. TAPE SEAMS AS REQ'D. 30 YEAR WARRANTY AND RATED FOR 180 DAY (MIN) UV EXPOSURE. PRODUCT IS TO BE COMPATIBLE WITH SIDING MFG SO AS NOT TO VOID ANY WARRANTIES.
3. FOR THE SLAB, G.C. TO PROVIDE 10 MIL POLY (MINIMUM) VAPOR BARRIER ABOVE FINISHED BASE AND BELOW
MONOLITHIC SLAB.
6. WOOD GROUNDS, NAILERS, BLOCKING AND FURRING:
A. PROVIDE FOR SCREEDING AND ANCHORAGE OF OTHER WORK. FORM TO SHAPES SHOWN AND AS
REQUIRED.
B. COUNTERSINK BOLTS AND NUTS FLUSH WITH SURFACES WHERE NECESSARY FOR FLUSH INSTALLATION.
C. PROVIDE GROUNDS OF DRESSED, KEY-BEVELED LUMBER NOT LESS THAN 1 12" WIDE AND OF
THICKNESS REQUIRED TO BRING FACE OF GROUND TO EXACT THICKNESS OF FINISH MATERIAL
INVOLVED. REMOVE TEMPORARY GROUNDS WHEN NO LONGER REQUIRED. WHERE INDICATED
AS PERMANENT GROUND, PROVIDE TREATED LUMBER.
7. WALL AND ROOF SHEATHING: PROVIDE EXTERIOR GRADE PER STRUCTURAL ENGINEER SPECIFICATIONS EXTERIOR WALLS AND ROOF. PROVIDE STRUCTURAL GRADE WHERE SHOWN ON THE STRUCTURAL DRAWINGS.
SHEATHING MUST BE COVERED WITH VAPOR BARRIER ON ROOFS AND WALLS. G.C. TO TAPE SEAMS AS REQ'D. AND SUBMIT MANUF. WARRANTIED PRODUCT FOR REVIEW BY THE ARCHITECT IN A SUBMITTED SHOP DRAWING.
COVER SHEATHING AS SOON AS POSSIBLE AFTER INSTALLATION. DO NOT COVER WET OR DAMP SHEATHING.
SHEATHING MUST BE DRY BEFORE INSTALLING MOISTURE PROTECTION. INSTALL SHEATHING IN
ACCORDANCE WITH LOCAL AND STATE BUILDING CODES.
CABINETWORK AND ARCHITECTURAL WOODWORK (06410):
1. PROVIDE SHOP FABRICATED CABINETWORK AND ARCHITECTURAL WOODWORK ITEMS
COMPLETE WITH HARDWARE AND ACCESSORIES, AS INDICATED ON ARCHITECTURAL DRAWINGS.
2. ALL CABINETWORK AND ARCHITECTURAL WOODWORK INDICATED ON ARCHITECTURAL
DRAWINGS SHALL BE FABRICATED IN ACCORDANCE WITH THE STANDARDS OF THE "ARCHITECTURAL WOODWORKING INSTITUTE" (AWI), INCLUDING WOOD SELECTION, JOINERY, SIZING FASTENING
AND SHOP FINISHING AS FOLLOWS:
A. "CUSTOM GRADE" FOR PLASTIC LAMINATE OR OPAQUE FINSHED MILLWORK FINISHES
AS INDICTED ON THE DRAWINGS.
B. "HIGH PRESSURE LAMINATE AS AN ARCHITECTURAL WOODWORK MATERIAL" REFERENCED FOR
PLASTIC LAMINATE MILLWORK.
C. "PREMIUM GRADE" FOR EXPOSED WOOD VENEER MILLWORK
3. ALL WOOD SHALL BE FIRE-RETARDANT TREATED AND SHALL COMPLY WITH REQUIREMENTS OF THE
LOCAL BUILDING CODE.
4. SUBMITTALS:
A. SUBMIT THE FOLLOWING IN ACCORDANCE WITH DIVISION 1, SECTION 01340
B. SUBMIT SHOP DRAWINGS FOR ALL ARCHITECTURAL WOODWORK INCLUDING DIMENSIONED
PLANS, ELEVATIONS, CROSS-SECTIONS, AND LARGE-SCALE DETAILS OF CONSTRUCTION TO
ARCHITECT FOR REVEIW PRIOR TO FABRICATION. SHOP DRAWINGS SHALL INDICATE MATERIALS AND WOOD SPECIES, COMPONENT PROFILES, FASTENING, JOINTING, FINISHES, HARDWARE AND
ACCESSORIES; AND ADJACENT WORK OF OTHER TRADES.
C. SUBMIT THREE (3) SAMPLES OF ALL ARCHITECTURAL WOODWORK FINISHES: PAINTED, LACQUER, AND PLASTIC LAMINATE, TO ARCHITECT FOR REVIEW AND ACCEPTANCE PRIOR TO FABRICATION.
D. SUBMIT CERTIFICATION OF FIRE-RETARDANT TREATMENT OF WOOD STATING THE NAME OF
FIRE-RETARDANT MATERIALS USED, AND COMPLIANCE WITH AWPA SPECIFICAITON C1 AND C20
FOR LUMBER.
5. PROTECT ALL ARCHITECTURAL WOODWORK ITEMS DURING TRANSIT, DELIVERY, STORAGE AND HANDLING TO PREVENT DAMAGE, SOILING AND DETERIORATION. THE WOODWORK CONTRACTOR AND GENERAL CONTRACTOR SHALL BE JOINTLY RESPONSIBLE TO MAKE CERTAIN THAT WOOD WORKING IS NOT DELIVERED UNTIL PAINTING, WET WORK
AND SIMILAR OPERATIONS WHICH COULD DAMAGE FINISH WORK HAS BEEN COMPLETED.
6. CONTRACTOR SHALL HAVE EXAMINED THE JOB SITE IN CONJUNCTION WITH PROJECT DOCUMENTS SO AS TO BE SATISFIED AS TO THE CONDITIONS UNDER WHICH THE WORK WILL BE PERFORMED, INCLUDING SUCH MATTERS AS UNLOADING FACILITIES, LOCATION AND SIZE OF ELEVATORS, EQUIPMENT OR DOCK FACILITIES AND ANY OTHER CONDITIONS
NEEDED PRELIMINARY TO AND DURING THE WORK.
7. WOODWORK CONTRACTOR SHALL NOTIFY THE ARCHITECT IN WRITING OF ANY DISCREPANCIES BETWEEN THE DRAWINGS AND FIELD CONDITIONS AND SHALL NOT PROCEED WITH THE PORTION OF WORK IN QUESTION UNITL THE DISCREPANCIES
ARE CLARIFIED.
8. MATERIALS:
A. PLASTIC LAMINATE COLOR, MANUFACTURER, AND FINISH AS DESIGNATED ON FINISH PLANS, SHALL BE OF THE FOLLOWING TYPES FOR SPECIFIC APPLICATION, CONFORMING TO NEMA LD-3 AND ARCHITECT APPROVED SAMPLES. ADHESIVE: CONTACT TYPE, FS MM-A 130, AS RECOMMENDED BY MANUFACTURER TO SUIT APPLICATION.
1. HORIZONTAL SURFACES: GENERAL PURPOSE TYPE, NOMINAL 0.050 INCH.
2. VERTICAL SURFACES: VERTICAL SURFACE TYPE, NOMINAL 0.032 INCH.
3. UNEXPOSED SURFACES: BALANCED WITH 0.020 INCH BACKING SHEET.
4. BASES: SPECIFIED PURPOSE TYPE, NOMINAL 0.125 INCH.
5. POSTFORMED COUNTERTOPS: POSTFORMING TYPE, NOMINAL 0.040 INCH.
6. SEMI-EXPOSED SURFACES: CABINET LINER, LOW PRESSURE POLYESTER OVERLAY, NOMINAL 0.020 INCH, UNLESS NOTED TO RECEIVE PLASTIC LAMINATE ON DRAWINGS.
B. EXPOSED WOOD VENEER SHALL BE STAINED TO MATCH EXISTING, OPEN PORE W/STAIN RUBBED LACQUER FINISH.
PROVIDE THE FOLLOWING MATCH AND ASSEMBLY FOR CONTINUOUS SEQUENTUAL USE OF FLITCHES OR EACH SEPARATE EXPANSE OF MATCHED WORK AS INDICATED (I.E. PANELS, DOORS, AND CASEWORK).
1. HORIZONTAL MATCH: BOOK MATCH
2. VERTICAL MATCH: END MATCH
3. ASSEMBLY: CENTER MATCH EACH ASSEMBLY (USE EVEN NUMBER OF EQUAL WIDTH PIECES TO MAKE UP
PANEL WIDTH).
9. CABINET HARDWARE AND RELATED ACCESSORIES SHALL BE INDICATED ON MILLWORK DETAILS FOR APPROVAL.
10. JUST PRIOR TO OWNER ACCEPTANCE, REMOVE PROTECTIVE COVERING, TOUCH UP AS REQUIRED, WIPE CLEAN, ADJUST AND LUBRICATE HARDWARE, AND CHECK FOR PROPER OPERATION OF ALL ITEMS. COORDINATE THIS WITH THE GENERAL
CONTRACTOR.
11. WOOD SUBSTRATE SHALL BE 34" PLYWOOD WITH LAMINATE VENEER APPLIED FINISH. TRIM MOULDING SHALL BE
APPLIED OVER JOINTS OF VENEER SO THAT MINIMAL JOINTS ARE VISIBLE.
12. PROVIDE SOLID HARDWOOD TRIM OF STAIN/PAINT GRADE TO MATCH SAMPLE FOR BASE TRIM.
PROVIDE SHAPES AND THICKNESS SHOWN ON PLANS. ALL WORK IS TO BE TAPERED AND MITERED IN A
PROFESSIONAL MANNER.
METAL ROOF SYSTEMS (07610):
GENERAL:
1. ROOFING : PROVIDE LAYOUTS OF PANELS ON WALLS AND ROOFS, DETAILS OF EDGE CONDITIONS, JOINTS, CORNERS, CUSTOM PROFILES, SUPPORTS, ANCHORAGES, TRIM, FLASHINGS, CLOSURES, AND SPECIAL DETAILS. INCLUDE TRANSVERSE
CROSS-SECTIONS.
2. SAMPLES FOR INITIAL SELECTION PURPOSES IN FORM OF MANUFACTURER'S COLOR CHARTS OR CHIPS SHOWING FULL RANGE OF COLORS, TEXTURES, AND PATTERNS AVAILABLE FOR METAL ROOFING AND SIDING PANELS WITH FACTORY-APPLIED FINISHES.
3. INSTALLER CERTIFICATES SIGNED BY METAL BUILDING MANUFACTURER WRITTEN CERTIFICATION CERTIFYING THAT THE INSTALLER
COMPLIES WITH REQUIREMENTS INCLUDED UNDER THE "QUALITY ASSURANCE" ARTICLE.
4. ALL METAL ROOFING MANUFACTURERS THAT MEET THE SPECIFICATIONS WILL BE CONSIDERED. REVIEW OF PRODUCT WILL TAKE PLACE DURING SUBMITTAL PROCESS AFTER BID HAS BEEN AWARDED. ANY AND ALL COSTS ASSOCIATED WITH THE METAL ROOF, SUBSTRATE, OR WARRANTIES - INCLUDING SELF-INSURED - SHALL BE INCLUDED IN THE BIDS. CHANGE ORDERS WILL NOT BE
ACCEPTED.
QUALITY ASSURANCE:
1. INSTALLER QUALIFICATIONS: ENGAGE AN EXPERIENCED INSTALLER WHO HAS SPECIALIZED IN THE ERECTION AND INSTALLATION OF TYPES OF METAL ROOFING SYSTEMS SIMILAR TO THAT REQUIRED FOR THIS PROJECT AND WHO IS CERTIFIED IN WRITING BY THE CONTRACTOR MANUFACTURER AS QUALIFIED FOR ERECTION OF THE MANUFACTURER'S PRODUCTS.
COORDINATE METAL ROOF ASSEMBLIES WITH RAIN DRAINAGE WORK, FLASHING, TRIM, AND CONSTRUCTION OF SUPPORTS AND OTHER ADJOINING WORK TO PROVIDE A LEAKPROOF, SECURE, AND NONCORROSIVE INSTALLATION.
WARRANTY:
1. SPECIAL WARRANTY ON METAL FINISHES: MANUFACTURER'S STANDARD FORM IN WHICH MANUFACTURER AGREES TO REPAIR FINISH OR REPLACE METAL ROOF THAT SHOW EVIDENCE OF DETERIORATION OF FACTORY-APPLIED FINISHES WITHIN SPECIFIED
WARRANTY PERIOD.
2.KYNAR 500 FINISH: DETERIORATION INCLUDES, BUT IS NOT LIMITED TO, THE FOLLOWING:
-COLOR FADING MORE THAN 5 HUNTER UNITS WHEN TESTED ACCORDING TO ASTM D 2244.
-CHALKING IN EXCESS OF A NO. 8 RATING WHEN TESTED ACCORDING TO ASTM D 4214.
-CRACKING, CHECKING, PEELING, OR FAILURE OF PAINT TO ADHERE TO BARE METAL. FINISH WARRANTY PERIOD: 20 YEARS FROM
DATE OF SUBSTANTIAL COMPLETION.
-SPECIAL WEATHERTIGHTNESS WARRANTY FOR STANDING-SEAM METAL ROOF PANELS: MANUFACTURER'S STANDARD FORM IN WHICH MANUFACTURER AGREES TO REPAIR OR REPLACE STANDING-SEAM, METAL ROOF PANEL ASSEMBLIES THAT FAIL TO REMAIN WEATHERTIGHT, INCLUDING LEAKS, WITHIN SPECIFIED WARRANTY PERIOD. WARRANTY PERIOD: 30 YEARS FROM DATE OF SUBSTANTIAL COMPLETION. IT SHALL INCLUDE ANY NECESSARY ENHANCED WIND RIDERS TO MEET THE REQUIRED 130MPH WIND
RATING. NO EXCEPTIONS.
3. G.C. HOLDS THE RIGHT TO COMPLETELY ICE AND WATER SHIELD ENTIRE ROOF TO OBTAIN WEATHERTIGHT WARRANY OR
SELF-INSURE BY HIRING THIRD PARTY INSPECTOR TO VERIFY PROPER INSTALLATION.
ROOFING:
1. ROOF PANELS: MANUFACTURER'S STANDARD FACTORY-FORMED ROOF PANEL SYSTEM DESIGNED FOR THROUGH FASTENING OF PANELS TO ROOF FRAMING. FORM PANELS OF 0.32 ALUMINUM SHEETS WITH 16" COVERAGE AND 1 34" MIN.
STANDING SEAMS. ROOF PANEL PAINTING SHALL BE KYNAR 500 OR APPROVED EQUAL.
2. FASTENERS: SELF-TAPPING SCREWS, BOLTS, NUTS, SELF-LOCKING RIVETS, SELF-LOCKING BOLTS, END WELDED STUDS, AND
OTHER SUITABLE FASTENERS DESIGNED TO WITHSTAND DESIGN LOADS.
3. PROVIDE METAL-BACKED NEOPRENE WASHERS UNDER HEADS OF FASTENERS BEARING ON WEATHER SIDE OF PANELS.
4. LOCATE AND SPACE FASTENINGS IN TRUE VERTICAL AND HORIZONTAL ALIGNMENT. USE PROPER TOOLS TO OBTAIN CONTROLLED UNIFORM COMPRESSION FOR POSITIVE SEAL WITHOUT RUPTURE OF NEOPRENE WASHER.
5. PROVIDE FASTENERS WITH HEADS MATCHING COLOR OF ROOFING OR SIDING SHEETS BY MEANS OF PLASTIC CAPS OR
FACTORY-APPLIED COATING AS REQUIRED BY ROOFING SYSTEM.
6. MANUFACTURER TO PROVIDE STRIATIONS AS REQ'D. TO AVOID "OIL CANNING".
INSTALLATION:
1. PROVIDE METAL ROOF PANELS OF FULL LENGTH FROM EAVE TO RIDGE, UNLESS OTHERWISE INDICATED OR
RESTRICTED BY SHIPPING LIMITATIONS.
2. INSTALL RIDGE AND HIP CAPS AS METAL ROOF PANEL WORK PROCEEDS.
3. FLASH AND SEAL METAL ROOF PANELS WITH WEATHER CLOSURES AT EAVES AND RAKES. FASTEN WITH
SELF-TAPPING SCREWS.
4. STANDING-SEAM METAL ROOF PANELS: FASTEN METAL ROOF PANELS TO SUPPORTS WITH CONCEALED CLIPS AT EACH STANDING-SEAM JOINT AT LOCATION, SPACING, AND WITH FASTENERS RECOMMENDED BY MANUFACTURER.
5. INSTALL CLIPS TO SUPPORTS WITH SELF-TAPPING FASTENERS.
6. INSTALL PRESSURE PLATES AT LOCATIONS INDICATED IN MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS.
7. SNAP JOINT: NEST STANDING SEAMS AND FASTEN TOGETHER BY INTERLOCKING AND COMPLETELY ENGAGING
FACTORY-APPLIED SEALANT.
8. SEAMED JOINT: CRIMP STANDING SEAMS WITH MANUFACTURER-APPROVED MOTORIZED SEAMER TOOL SO CLIP, METAL
ROOF PANEL, AND FACTORY-APPLIED SEALANT ARE COMPLETELY ENGAGED.
9. RIGIDLY FASTEN EAVE END OF METAL ROOF PANELS AND ALLOW RIDGE END FREE MOVEMENT DUE TO THERMAL
EXPANSION AND CONTRACTION. PREDRILL PANELS FOR FASTENERS.
10. PROVIDE METAL CLOSURES AT PEAKS, RAKE EDGES AND EACH SIDE OF RIDGE AND HIP CAPS.
11.METAL ROOF PANEL INSTALLATION TOLERANCES: SHIM AND ALIGN METAL ROOF PANELS WITHIN INSTALLED TOLERANCE OF 1/4 INCH IN 20 FEET (6 MM IN 6 M) ON SLOPE AND LOCATION LINES AS INDICATED AND WITHIN 1/8-INCH (3-MM) OFFSET OF
ADJOINING FACES AND OF ALIGNMENT OF MATCHING PROFILES.
12. INSTALL THICKER ROOF SHEATHING AS REQUIRED BY ROOF MANUFACTURER TO MEET HIGH WIND ZONES.
ACCESSORY INSTALLATION:
1. INSTALL ACCESSORIES WITH POSITIVE ANCHORAGE TO BUILDING AND WEATHERTIGHT MOUNTING, AND PROVIDE FOR
THERMAL EXPANSION. COORDINATE INSTALLATION WITH FLASHINGS AND OTHER COMPONENTS.
2. INSTALL COMPONENTS REQUIRED FOR A COMPLETE METAL ROOF PANEL ASSEMBLY INCLUDING TRIM, COPINGS, RIDGE CLOSURES, SEAM COVERS, FLASHINGS, SEALANTS, GASKETS, FILLERS, CLOSURE STRIPS, AND SIMILAR ITEMS.
3. INSTALL COMPONENTS FOR A COMPLETE METAL WALL PANEL ASSEMBLY INCLUDING TRIM, COPINGS, CORNERS, SEAM COVERS, FLASHINGS, SEALANTS, GASKETS, FILLERS, CLOSURE STRIPS, AND SIMILAR ITEMS.
4. WHERE DISSIMILAR METALS WILL CONTACT EACH OTHER OR CORROSIVE SUBSTRATES, PROTECT AGAINST GALVANIC ACTION BY PAINTING CONTACT SURFACES WITH BITUMINOUS COATING, BY APPLYING RUBBERIZED-ASPHALT UNDERLAYMENT TO EACH CONTACT SURFACE, OR BY OTHER PERMANENT SEPARATION AS RECOMMENDED BY MANUFACTURER.
5. FLASHING AND TRIM: COMPLY WITH PERFORMANCE REQUIREMENTS, MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS, AND SMACNA'S "ARCHITECTURAL SHEET METAL MANUAL." PROVIDE CONCEALED FASTENERS WHERE POSSIBLE, AND SET UNITS TRUE TO LINE AND LEVEL AS INDICATED. INSTALL WORK WITH LAPS, JOINTS, AND SEAMS THAT WILL BE PERMANENTLY WATERTIGHT
AND WEATHER RESISTANT.
6. INSTALL EXPOSED FLASHING AND TRIM THAT IS WITHOUT EXCESSIVE OIL CANNING, BUCKLING, AND TOOL MARKS AND THAT IS TRUE TO LINE AND LEVELS INDICATED, WITH EXPOSED EDGES FOLDED BACK TO FORM HEMS. INSTALL SHEET METAL FLASHING AND TRIM TO FIT SUBSTRATES AND TO RESULT IN WATERPROOF AND WEATHER-RESISTANT PERFORMANCE.
7. EXPANSION PROVISIONS: PROVIDE FOR THERMAL EXPANSION OF EXPOSED FLASHING AND TRIM. SPACE MOVEMENT JOINTS AT A MAXIMUM OF 10 FEET (3 M) WITH NO JOINTS ALLOWED WITHIN 24 INCHES (600 MM) OF CORNER OR INTERSECTION. WHERE LAPPED OR BAYONET-TYPE EXPANSION PROVISIONS CANNOT BE USED OR WOULD NOT BE SUFFICIENTLY WEATHER RESISTANT AND WATERPROOF, FORM EXPANSION JOINTS OF INTERMESHING HOOKED FLANGES, NOT LESS THAN 1 INCH (25 MM) DEEP, FILLED WITH MASTIC SEALANT (CONCEALED WITHIN JOINTS).
GUTTERS AND DOWN SPOUTS:
1. G.C. TO LOCATE IN THE FIELD AND TIE INTO CIVIL AS REQ'D.
2. TO BE ALUMINUM K STYLE SEAMLESS GUTTER (4 12" X 6") W/ 3"X4" BOX DOWNSPOUT (MIN.) (SEE PLANS FOR LOCATIONS).
3. COLOR TO MATCH ROOF.
4. SUBMIT SAMPLES TO ARCHITECT FOR APPROVAL PRIOR TO PURCHASE.
C
SHEET:
STAMP:
SCALE:
DATE:
DRAWN BY:
ARCHITECTURE + DESIGN, P.L.L.C.
P.O. BOX 1827
KITTY HAWK, NC 27949
PH: (252) 441-6767, FAX (252) 261-6045
BEACON
DRAWING NAME:
ATTENDANT
Beaufort County North Carolina
BUILDING
PROJECT NAME:
CN
2406 Princess Anne Road
Virginia Beach, VA 23456 Phone (757) 563-9027
Facsimile(757) 563-9028
Suite 200
COASTAL
E N G I N E E R I N G
PME ENGINEER:
2026 BEACON ARCHITECTURE + DESIGN
P.L.L.C.- ALL RIGHTS RESERVED
3 / 30 / 26
REVISIONS: DATE:
STRUCTURAL ENGINEER:
RPA ENGINEERING, PE
102 REGENCY BLVD., SUITE A1
GREENVILLE, NORTH CAROLINA
PH: (252) 321-6027
Stilley Station
ISSUED FOR
BID
ISSUE FOR BID
3 / 30 / 26
3 / 30 / 26
NOT TO SCALE
T1.2
SPECIFICATIONS
DIVISION 8: DOORS, WINDOW & GLASS
EXTERIOR BUILDING SIDING AND TRIM (07460):
1. 0.46"-0.52" THICK MIN, VINYL 7" TRADITIONAL LAP OR BOARD & BATTEN SIDING BY CERTAINTEED CERTA PLANK/BOARD & BATTEN OR EQUIVALENT: STYLE AND LOCATION AS INDICATED ON THE BUILDING ELEVATIONS FOR DESIGN INTENT.
2. REFER TO SELECTED MFG. FOR INSTALLATION INSTRUCTIONS AND ADDITIONAL SPECIFICATION INFO.
3. VINYL SIDING TO HAVE ROUGH CEDAR TEXTURE.
4. SUBMIT SAMPLE TO ARCHITECT FOR APPROVAL PRIOR TO PURCHASE.
5. SIDING AND TRIM IS TO BE WARRANTEE FOR LIFETIME AND ACCEPTABLE FOR USE IN EXTREME COASTAL ENVIRONMENTS.
6. FASTENERS TO BE APPROVED BY THE SELECTED MANUFACTURER TO CONFORM TO PRODUCT SPECIFICATIONS AND
TO PROVIDE CORROSION RESISTANCE.
7. ALL VINYL SIDING PRODUCTS TO RECEIVE A FACTORY PRIMER WITH TOP COAT APPLIED IN THE FIELD TO THE SPECS. OF THE
SELECTED PRODUCT MANUFACTURER TO MAINTAIN WARRANTY.
8. COLOR TO BE DETERMINED BY THE ARCHITECT AND CLIENT IN THE FIELD.
9. PROVIDE VENTED VINYL SIDING SHEET MATERIALS FOR EXTERIOR SOFFITS AND SOFFIT FASCIAS. (USE 12' LONG SHEETS)
10. BUILDING TRIM TO BE SOLID 54" THICK EXTRUDED PVC, OR EQUIVALENT, OF SIZES AND LOCATIONS TO MATCH ELEVATIONS.
REFER TO SELECTED MFG. FOR INSTALLATION INSTRUCTIONS
11. TRIM, SIDING, AND SOFFIT MATERIAL TO HAVE A WOOD GRAIN FINISH. SEE ARCH. DRAWINGS FOR MORE INFORMATION.
PRODUCT SHOULD BE PAINTABLE PER SELECTED MFG SPECIFICATIONS. ONE-PIECE CORNER TRIM IS ACCEPTABLE IF IT MEETS
DIMENSIONAL REQ'S.
12. EXTERIOR BATTEN STRIPS TO BE SPACED AT APPROX. 8" O.C. MIN., NO EXCEPTIONS.
13. UNDER PORCHES, VENTED VINYL SOFFIT MATERIAL SHALL BE UTILIZED.
14. HORIZONTAL SEAMS WILL ONLY BE ACCEPTABLE AS INDICATED ON EXTERIOR ELEVATIONS.
SEALANTS AND CAULKING (07915):
GENERAL: ALL SEALANTS AND CAULKING SHALL BE NON-STAINING TO ADJACENT EXPOSED MATERIALS.
1. POLYURETHANE OR LOW MODULUS SILICONE SEALANTS: ONE PART SEALANT SHALL BE USED AT ALL EXTERIOR JOINTS, AT DOORS, WINDOWS AND WHERE DISSIMILAR MATERIALS ABUT. USE LEXEL CAULKING AS RECOMMENDED AND PRICED
BY GENERAL CONTRACTOR.
2. ACRYLIC LATEX CAULKING: ONE COMPONENT ACRYLIC WATER BASED COMPOUND TRIMFLEX 834 BY PECORA OR APPROVED EQUAL. USE LATEX CAULKING FOR ALL INTERIOR JOINTS. DO NOT USE IF TEMPERATURE IS BELOW 45 DEGREES F. (USE BUTYL RUBBER BASED PERCORA AC-20 BELOW 45 DEGREES F.)
3. BACKUP MATERIALS, FILLERS AND JOINT PACKING: AS RECOMMENDED BY SEALANT MANUFACTURER. IN GENERAL, USE
CLOSED CELL, BEAD OR ROPE SHAPED EXPANDED POLYURETHANE.
FINISH HARDWARE (08700):
1. PROVIDE FINISH HARDWARE AS INDICATED ON DOOR/HARDWARE SCHEDULE ON ARCHITECTURAL DRAWINGS.
2. SUBMITTALS:
A. FOLLOW IN ACCORDANCE WITH DIVISION 1 SECTION 01340.
B. PRODUCT DATA; SUBMIT MANUFACTURER CATALOG CUTS FOR EACH HARDWARE ITEM.
3. HARDWARE ITEMS:
A. SEE DOOR SCHEDULE FOR HARDWARE GROUP FUNCTIONS, LOCATIONS AND DOOR TYPES.
B. BUTTS: ALL EXTERIOR DOORS TO HAVE NONFERROUS BUTTS WITH NON-REMOVABLE PINS. LABELED DOORS SHALL HAVE STEEL BUTTS. WHERE LABELED DOORS ARE EXTERIOR OUT SWINGING, PROVIDE STAINLESS STEEL BUTTS UNLESS OTHERWISE SPECIFIED, SIZE OF BUTTS WILL BE DETERMINED BY THE
FOLLOWING TABLE:
1. SIZE AND TYPE
A. DOORS 1 34" THICK AND UP TO 41" WIDE: 4 12" HEAVYWEIGHT BALL BEARING
WINDOWS (08500):
1. WINDOWS SHALL BE AS SHOWN AND SCHEDULED.
2. ALL OPERABLE WINDOWS MUST HAVE INSECT SCREENS
3. FOR SIZING AND GRILLE PATTERNS SEE PLANS AND ELEVATIONS FOR FURTHER INFORMATION.
4. GLAZING TO BE LOW-E TO MATCH LOCAL DESIGN PRESSURE AND ASTM REQUIREMENTS FOR 130 MPH WIND PRESSURE AS
WELL AS NC COMMERCIAL ENERGY CODE REQUIREMENTS.
5. WEATHERSTRIPPING TO BE PROVIDED TO MEET REQUIREMENTS FOR EXTREME COASTAL ENVIRONMENTS.
6. COLOR IS TO BE WHITE TO MATCH THE EXTERIOR DOORS. SEE WINDOW SCHEDULE FOR MORE INFORMATION.
7. STRICTLY COMPLY WITH MANUFACTURERS INSTALLATION INSTRUCTIONS. FOLLOW FLASHING REQUIREMENTS CLOSELY.
8. G.C. TO PROVIDE PRE-CUT AND PREDRILLED 7
16" TH. STRUCTURAL PLYWOOD PANELS AND PROPER STAINLESS STEEL SCREWS
TO MEET BASELINE WINDBOURNE DEBRIS REQUIREMENTS. COORDINATE WITH LOCAL BUILDING INSPECTOR FOR ALL REQ'S.
9. ALL HARDWARE TO BE WARRANTIED FOR COASTAL LOCATIONS.
EXTERIOR DOORS (08100):
1. DOORS STYLE TO MATCH EXTERIOR ELEVATIONS AND DOOR SCHEDULE.
2. DOORS TO HAVE SMOOTH FINISH.
4. WEATHERSTRIPPING TO BE INSTALLED AS REQUIRED AND TO MEET ADA REQ'S.
5. HINGES AND STRIKES TO BE CORROSION RESISTANT MATERIAL (COASTAL HARDWARE) WITH SCREWS TO MATCH.
6. FRAME CAN BE FIELD CONSTRUCTED OR BE PROVIDED BY THE DOOR MANUFACTURER WITH PROFILE AND STOP TO
MATCH WALL THICKNESS.
7. ADA THRESHOLD AND ADA HARDWARE AT ALL EXTERIOR LOCATIONS PER THE DOOR SCHEDULE. NO EXCEPTIONS.
8. G.C. TO PROVIDE PRE-CUT AND PREDRILLED 7
16" TH. STRUCTURAL PLYWOOD PANELS AND PROPER STAINLESS STEEL SCREWS
TO MEET BASELINE WINDBOURNE DEBRIS REQUIREMENTS. COORDINATE WITH LOCAL BUILDING INSPECTOR FOR ALL REQ'S.
9. DOOR COLOR TO BE WHITE TO MATCH WINDOWS.
10. ALL DOORS TO MEET NC COMMERCIAL ENERGY CODE REQUIREMENTS.
INTERIOR DOORS (08200):
1. PROVIDE MOLDED WOOD COMPOSITE DOORS AS INDICATED ON ARCHITECTURAL DRAWINGS.
2. SOLID CORE WOOD DOORS; FLUSH TYPE 1 34" THICK (MINIMUM, UNLESS OTHERWISE NOTED) SOLID BLOCK OR STILE AND RAIL CORE. TYPE AS (5 PLY) CONSTRUCTION DOORS SHALL BE PREMIUM GRADE PER AWI STANDARDS. FACE VENEERS AND
SHALL FINISH BE INDICATED ON DOOR SCHEDULE.
A. PROVIDE SOLID WOOD BLOCKING FOR ALL DOOR HARDWARE SUCH THAT NO THROUGH BOLT WILL BE REQUIRED TO PERMANENTLY MOUNT HARDWARE ON DOOR. IF BLOCKING IS NOT PRACTICAL, PROVIDE STAVE-CORE WOOD DOORS.
B. EXECUTION: DOORS SHALL HAVE ALL HANDLING MARKS OR EFFECTS OF EXPOSURE TO MOISTURE. FINAL SANDING OVER ALL EXPOSED SURFACES USING 150 GRIT OR FINER SANDPAPER AND SHALL THEN BE BRUSHED CLEAN.
C. PRIME OR SEAL ALL WOOD DOORS ON ALL SIDES AND EDGES. WHERE ITEMS ARE FURNISHED PRE-PRIMED, TOUCH
UP ALL ABRASIONS.
3. INSTALLATION:
A. HANGING DOORS: ALL DOORS SHALL BE EXPERTLY HUNG, PLUMB AND LEVEL AND SHALL FIT SNUG AGAINST ALL STOPS.
FIT ACCURATELY AND HANG FREE FROM HINGE.
B. HARDWARE SHALL BE FITTED TO FINISHING AND THEN REMOVED AND FINISHING COMPLETED BEFORE FINAL INSTALLATION OF HARDWARE. FINISH HARDWARE MUST BE NEATLY AND PROPERLY INSTALLED IN ACCORDANCE WITH
BEST PRACTICES AS PRESCRIBED BY MANUFACTURERS AND AS APPROVED BY ARCHITECT.
GYPSUM WALLBOARD SYSTEMS (092000):
1. GYPSUM WALLBOARD MATERIALS AND INSTALLATION SHALL BE IN ACCORDANCE WITH RECOMMENDATIONS OF ASTM C645, C754, AND C840; AND GYPSUM ASSOCIATION GA-216.
A. FIRE-RATED CONSTRUCTION SHALL BE LISTED AND LABELED UL AND CONFORM TO REQUIREMENTS OF GOVERNING
CODES AND REGULATIONS.
B. THE CONTRACTOR SHALL BE RESPONSIBLE FOR USING COMPATIBLE PRODUCTS FOR COMPLETE CONSTRUCTION
ASSEMBLY.
2. GYPSUM WALLBOARD SHALL BE 58" THICK MIN. AS SPECIFIED ON THE ARCHITECTURAL PLANS, AND APPLIED VERTICALLY WITH SCREW FASTENERS, IN GENERAL, PROVIDE TAPING AND FINISH SPACKLING WITH COMPATIBLE MATERIAL. PARTITIONS SHALL BE BRACED OR SECURED SUFFICIENTLY FROM DEFLECTION OF 18" PER 10'-0" LENGTH IN ANY DIRECTION. PROVIDE TEMPORARY
BRACING OF PARTITIONING WORK WHERE REQUIRED TO DIMINISH DEFLECTION PROBLEMS.
3. JOINTS GREATER THAN 18" AT CEILINGS SHALL BE REJECTED. PROVIDE CAULKING AT CEILING FOR PARTITIONS THAT TERMINATE
AT THE CEILING.
4. . ALL DRYWALL PARTITIONING SHALL BE PLUMB, LEVEL, TRUE AND STRAIGHT, PROPERLY BRACED AND RIGID. SURFACES SHALL BE SMOOTH, UNTEXTURED, AND FREE FROM FLAWS AND DEFECTS IN A READY TO PAINT CONDITION. ALL TAPING AND FINISH SPACKLING SHALL BE PREPARED SO THAT LOCATION OF JOINTS AND BLEMISHES CANNOT BE DETECTED AFTER
WALL HAS BEEN PAINTED.
5. ALL DRYWALL IS TO BE TAPED, SANDED AND READY FOR PAINT APPLICATION, SEE FINISH SCHEDULE FOR PAINT SPECS.
DIVISION 9: FINISHES
PAINTING (09900):
1. APPLICATOR SHALL INSPECT ALL SURFACES SCHEDULED TO RECEIVE NEW FINISH. A WATER-BASED OR ACRYLIC EPOXY (SINGLE OR TWO-COMPONENT) SHALL BE USED FOR BEST ADHESION TO DRYWALL. TAPE, JOINTS AND INDENTATIONS SHALL NOT "TELESCOPE" OR READ THROUGH THE PAINT FINISH OR WALL COVERING DO NOT PROCEED WITH WORK UNTIL
UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED.
2. WORK SHALL BE 3 COAT APPLICATION USING COMPATIBLE PRIMERS AND PREPARATION ON SUBSTRATES AS RECOMMENDED BY FINISH COAT MANUFACTURERS. ALL PAINTING MATERIALS SHALL BE USED ONLY IN STRICT CONFORMANCE WITH THE MANUFACTURER'S LATEST PRINTED SPECIFICATIONS AND INSTRUCTIONS.
3. PAINT SHALL BE APPLIED BY SKILLED TRADESMEN AND SHALL BE FREE OF ALL RUNS, BRUSH MARKS, SAGS, HOLIDAYS AND
OTHER DEFECTS. ARCHITECT WILL REJECT SUCH DEFECTS.
4. EDGES ADJOINING OTHER MATERIALS OR COLORS SHALL BE SHARP AND CLEAN, WITHOUT OVERLAPPING.
5. BEFORE PAINTING WORK IS TO BEGIN, ARRANGEMENTS SHALL BE MADE FOR PROPER VENTILATION.
6. PROPER PRECAUTIONS SHALL BE TAKEN TO PROTECT ALL AREAS FROM PAINT DRIPS, SPLASHES, OVERLAY, ETC. ALL GLAZING
SHALL BE MASKED ON BOTH SIDES.
7. PROTECT FROM HIGH HUMIDITY AND MOISTURE FOR 10–14 DAYS TO ENSURE PROPER CURE.
8. PROVIDE A SAMPLE, MINIMUM 8 12" X 11" IN SIZE OF EACH PAINT TYPE FOR ARCHITECT'S REVIEW PRIOR TO COMMENCEMENT
OF WORK.
9. BEFORE PAINTING WORK IS TO BEGIN, THE FOLLOWING ENVIRONMENTAL CONDITIONS SHALL BE PROVIDED:
A. MAINTAIN INTERIOR OF BUILDING SPACE WITH TEMPERATURE OF 60 DEGREES F. MIN. AND 85 DEGREES F. MAXIMUM AND A RELATIVE HUMIDITY OF LESS THAN 70% FOR THREE DAYS PRIOR TO START OF PAINTING WORK, DURING THE PAINTING
PROCESS AND AFTER PAINTING WORK HAS BEEN APPLIED.
B. LIGHTING IN ALL SPACES SHALL BE FULL FINAL ILLUMINATION LEVEL. CONTRACTOR SHALL PROVIDE TEMPORARY
LIGHTING WHERE REQUIRED.
10 WHERE PAINTS ARE SPECIFIED, CONTRACTOR TO USE THE METHODS AND MATERIALS AS SPECIFIED BY THE MANUFACTURER.
11. COLORS AND FINISHES AS INDICATED IN FINISH SCHEDULE.
12. UPON SUBSTANTIAL COMPLETION OF THE CONTRACT OR WHEN SO DIRECTED BY THE ARCHITECT, THE CONTRACTOR SHALL RETOUCH ALL PORTIONS OF THE WORK HEREIN SPECIFIED TO BE PAINTED OR FINISHED WHICH MAY HAVE BEEN MARRED
OR DAMAGED.
SEALED CONCRETE (096100):
1. HIGH-PERFORMANCE NON-YELLOWING SEALER TO BE USED ON POROUS CONCRETE.
2. SEALER SHALL DRY TO A MATTE FINISH, ENHANCE COLOR AND PENTRATE THE SURFACE TO RETARD AND RESIST
OIL, FOOD, AND LIGHT STAINING.
3. PREPARE CONCRETE FLOOR PER MANUFACTURER SPECS PRIOR TO SEALANT APPLICATION. CLOSELY FOLLOW
MANUFACTURER'S RECOMMENDATIONS.
B. DOORS 1 34" THICK AND 41" TO 48" WIDE; 4 12" EXTRA HEAVYWEIGHT BALL BEARING OR
OILITE BEARING.
C. DOORS 2" THICK AND/OR OVER 48" WIDE: 5" EXTRA HEAVYWEIGHT BALL BEARING OR
OILITE BEARING.
2. PROVIDE WIDTHS SUFFICIENT TO CLEAR TRIM PROJECTION WHEN DOOR SWINGS 180 DEGREES.
3. PROVIDE 2 HINGES TO 60" HIGH, 3 HINGES TO 90" HIGH, 4 HINGES TO 120" HIGH FOR EACH DOOR LEAF, UNLESS OTHERWISE SPECIFIED OR INDICATED
4. FINISH: MATCH LOCKSET OR LATCHSET, UNLESS OTHERWISE SPECIFIED OR INDICATED.
C. LOCKSETS AND LATCHSETS; PROVIDE HEAVY DUTY CYLINDER (MORTISE) CASES OF METAL MATCHING SPECIFIED FINISH;
INTERIOR PARTS OF STEEL AND ZINC-DICHROMATE PLATING TO RESIST RUSTING AND CORROSION. DO NOT SUPPLY PLASTIC, DIE-CAST OR ALUMINIUM MECHANISMS. CYLINDERS SHALL HAVE FULL ROUND PLUGS OF
EXTRUDED BRASS BAR MATERIAL, AND BE 6-PIN TUMBLER TYPE.
1. FINISH: COORDINATE WITH ARCHITECT AND TOWN IN THE FIELD
2. BACK SET: MATCH FINISH
3. STRIKES- PROVIDE STANDARD BOX-TYPE STRIKES; FURNISH WITH EXTENDED LIPS WHERE REQUIRED TO PROTECT TRIM FROM BEING MARRED BY LATCH BOLT. VERIFY WHETHER STANDARD OR ANSI CUTOUTS ARE
PROVIDED IN METAL FRAMES.
D. KEYS AND KEYING - COORDINATE KEYING WITH OWNERS.
1. PROVIDE 2 GRAND MASTER KEYS TO ACCESS ALL BUILDING DOORS.
2. PROVIDE 2 MASTER KEYS EACH FOR INTERIOR AND EXTERIOR DOORS.
3. KEY ALL INTERIOR DOORS INDIVIDUALLY.
4. PROVIDE 2 KEYS FOR EACH LOCKSET.
5. PROVIDE A LOCKABLE KEY BOX TO BE HUNG WHERE DIRECTED BY OWNER.
E. CLOSERS- EXTERIOR AND INTERIOR DOORS: 5 POUNDS, COMMERCIAL GRADE ONLY.
F. DOOR STOPS- PROVIDE BASE MOUNTED STOPS AT ALL INTERIOR DOORS. FINISH TO MATCH LOCKSETS.
VINYL WALL BASE (096513):
1. COMMERCIAL 4" HIGH, 0.080" GAUGE, BASE.
2. PROVIDE SAMPLES FOR REVIEW BY THE ARCHITECT PRIOR TO INSTALL. SEE DIVISION 1 FOR MORE INFORMATION.
4. INSTALLATION:
A. EXAMINE THE SUBSTRATE AND CONDITIONS UNDER WHICH THE FLOORING IS TO BE INSTALLED AND NOTIFY THE ARCHITECT IN WRITING OF CONDITIONS DETRIMENTAL TO THE PROPER AND TIMELY COMPLETION OF THE WORK.
B. SURFACES MUST BE DRY, CLEAN, STRUCTURALLY SOUND AND FREE FROM MOISTURE, ALKALI, DUST, DIRT, WAX, OILS, GREASE, LOOSE PAINT OR PLASTER, WALL COVERINGS OR OTHER FOREIGN MATTER.
C. USE PROPER ADHESIVE FOR SUBSTRATE.
D. FOLLOW MANUFACTURERS INSTALLATION METHOD INCLUDING THAT OF INSIDE/OUTSIDE CORNER PIECE SIZNG, MITERED OR WRAPPED CORNERS.
DIVISION 10
FIRE PROTECTION SPECIALTIES (104400):
1. PROVIDE FIRE EXTINGUISHERS AND FIRE EXTINGUISHER CABINETS AS REQUIRED BY BUILDING INSPECTOR. 1 FOR EVERY
3,000 SF AND NO MORE THAN 75' WALKING DISTANCE. PROVIDE TACTILE SIGNAGE.
2. FIRE EXTINGUISHERS SHALL MEET THE FOLLOWING CRITERIA:
A. EXTINGUISHERS SHALL BE MULTI PURPOSE (MP) TYPE DRY CHEMICAL A B C
B. PROVIDE 5-10 POUND ADA COMPLIANT UNITS AS REQ'D BY FIRE MARSHALL.
3. PROVIDE FIRE EXTINGUISHER CABINETS MEETING THE FOLLOWING CRITERIA:
A. THE UNIT SHALL BE ALUMINUM WITH A FLAT TRIM FRAME.
C. PROVIDE AN ADA COMPLIANT UNIT MOUNTED TO ADA STANDARDS.
D. UNIT SHALL BE AS MANUFACTURED BY LARSEN MFG. OR EQUIVLANENT
4. INSTALL IN STRICT ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS USING ONLY THOSE COMPONENTS
SUPPLIED BY OR APPROVED BY THE MANUFACTURER.
5. PROVIDE EXTINGUISHERS AND CABINETS BY THE SAME MANUFACTURER. UNITS ARE TO BE AS MANUFACTURED
BY LARSEN'S MFG. CO. OR APPROVED EQUAL.
DIVISIONS 11, 13 AND 14
NOT APPLICABLE
DIVISION 12: FURNISHINGS
COMMERCIAL PLUMBING FIXTURES (224200):
WATER CLOSET:
1. SHALL BE AN ADA COMPLIANT VITREOUS CHINA ELONGATED FLOOR MOUNTED.
2. HIGH EFFICIENCY, LOW CONSUMPTION WATER CLOSET. SEE PLUMBING ENGINEERING DRAWINGS FOR GPF.
3. BOWL TO BE FULLY GLAZED.
4. ADJUSTABLE SANITARY FLUSH.
5. MATERIALS SHALL BE CHLORAMINE RESISTANT.
6. TOILET FLUSHERS ON WIDE SIDE OF WATER CLOSETS, TYP.
LAVATORY SINKS:
1. SHALL BE ADA COMPLIANT VITREOUS CHINA WALL MOUNTED OVAL BASIN W/ OVERFLOW.
2. ALL EXPOSED PIPES (PLUMBING & DRAIN) TO BE COVERED AND/OR INSULATED.
3. G.C. TO COORDINATE FAUCET HOLE CUTOUTS.
LAVATORY FAUCET:
1. ADA COMPLIANT LAVATORY OR DECK MOUNTED FAUCET SHALL BE CHROME PLATED SOLID CAST BRASS BODY WITH
CENTER SHANK MOUNTING, 0.5 GPM AERATOR AND FLEXIBLE STAINLESS STEEL SUPPLY HOSE.
KITCHENETTE SINK:
1. SHALL BE 20-GA. (MIN.) STAINLESS STEEL DROP-IN SINGLE BASIN WITH THREE FAUCET HOLES.
KITCHENETTE FAUCET:
1. ADA COMPLIANT LEVER HANDLE HIGH GOOSE-NECK KITCHEN FAUCET.
2. LEVER HANDLES SHALL HAVE WIDESPREAD INSTALLATION - 3 HOLE FAUCET WITH 8" CENTERS.
COMMERCIAL TOILET ACCESSORIES (102813):
GRAB BARS:
1. SHALL BE ADA COMPLIANT TYPE-304 STAINLESS STEEL WITH PEENED GRIPPING SURFACE.
2. SHALL HAVE 18-GUAGE WALL THICKNESS AND 1 14" - 2" OUTSIDE DIAMETER.
3. CLEARANCE BETWEEN GRAB BAR AND WALL SHALL BE 1 12".
4. CONCEALED MOUNTING FLANGES SHALL BE 22-GUAGE STAINLESS STEEL , 3 14" DIAMETER, AND SHALL SNAP OVER
MOUNTING FLANGES TO CONCEAL MOUNTING SCREWS AND/OR FASTENERS.
5. END OF GRAB BAR SHALL PASS THROUGH CONCEALED MOUNTING FLANGES AND BE HELIARC WELDED TO FORM
ONE STRUCTURAL UNIT.
6. GRAB BAR SHALL COMPLY WITH ACCESSIBLE DESIGN (INCLUDING ADAAG IN THE U.S.A.) FOR STRUCTURAL STRENGTH.
7. G.C. TO INSTALL IN-WALL BLOCKING FOR GRABBARS.
TOILET TISSUE DISPENSER:
1. ADA COMPLIANT SURFACE MOUNTED MULTI-ROLL TOILET TISSUE DISPENSER SHALL BE TYPE-304 STAINLESS STEEL WITH
ALL-WELDED CONSTRUCTION, INCLUDING DISPENSING MECHANISM, INNER HOUSING AND CAM.
2. ALL EXPOSED SURFACES SHALL HAVE SATIN FINISH.
3. FRONT OF TISSUE DISPENSER SHALL BE DRAWN, ONE PIECE, SEAMLESS CONSTRUCTION. DOOR SHALL BE SECURED TO CABINET WITH TWO RIVETS AND EQUIPPED WITH TUMBLER LOCK KEYED LIKE OTHER WASHROOM ACCESSORIES.
4. UNIT SHALL DISPENSE TWO STANDARD-CORE TOILET TISSUE ROLLS UP TO 9" DIAMETER.
5. UNIT SHALL BE EQUIPPED WITH TWO THEFT-RESISTANT, HEAVY-DUTY, ONE PIECE, MOLDED ABS SPINDLES.
SOAP DISPENSER:
1. ADA COMPLIANT WALL MOUNTED SOAP DISPENSER, SHALL BE SATIN FINISH STAINLESS STEEL WITH
CHROME-PLATED BRASS PUMP VALVE.
2. UNIT SHALL BE ABLE TO DISPENSE .027 OZ OF LIQUID OR FOAM SOAP.
PAPER TOWEL DISPENSER:
1. SHALL BE EASY PULL DOWN TOWEL DISPENSER
2. SHALL BE WALL MOUNTED SO THAT DISPENSING NOZZLE IS ADA COMPLIANT FOR REACH RANGES.
3. SHALL BE WASTE MINIMIZING W/ ONE-AT-A-TIME TOWEL DISPENSING.
4. SHALL BE EASY TO REFILL, SELF-THREADING UNIT DESIGN.
COUNTERTOPS (123600):
COUNTERTOP SURFACE:
1. SURFACE SHALL BE ADA COMPLIANT COMMERCIAL GRADE HIGH-PRESSURE PLASTIC LAMINATE.
2. PROVIDE SAMPLES FOR REVIEW BY THE ARCHITECT PRIOR TO INSTALL. SEE DIVISION 1 FOR MORE INFORMATION.
DIVISION 22: PLUMBING
C
SHEET:
STAMP:
SCALE:
DATE:
DRAWN BY:
ARCHITECTURE + DESIGN, P.L.L.C.
P.O. BOX 1827
KITTY HAWK, NC 27949
PH: (252) 441-6767, FAX (252) 261-6045
BEACON
DRAWING NAME:
ATTENDANT
Beaufort County North Carolina
BUILDING
PROJECT NAME:
CN
2406 Princess Anne Road
Virginia Beach, VA 23456 Phone (757) 563-9027
Facsimile(757) 563-9028
Suite 200
COASTAL
E N G I N E E R I N G
PME ENGINEER:
2026 BEACON ARCHITECTURE + DESIGN
P.L.L.C.- ALL RIGHTS RESERVED
3 / 30 / 26
REVISIONS: DATE:
STRUCTURAL ENGINEER:
RPA ENGINEERING, PE
102 REGENCY BLVD., SUITE A1
GREENVILLE, NORTH CAROLINA
PH: (252) 321-6027
Stilley Station
ISSUED FOR
BID
ISSUE FOR BID
3 / 30 / 26
3 / 30 / 26
NOT TO SCALE
T1.3
SPECIFICATIONS
+ 12" A.F.F. MAX.
SLOPE
FLOOR AT
THRESHOLD
INSWING DOOR
(32" CLEAR
MIN.)
+/- 7'-10 3/4" CLR. MIN.
4" M
IN
MAX.
STORAGE ROOM
(UNCONDITIONED,
NO STORAGE OF HAZARDOUS
MATERIALS)
'-0
6' -5
/2
'-6
/2
OPEN OFFICE
CABINET DEPTH
REFRIGERATOR
PURCHASED AND
INSTALLED BY
COUNTY.
FS-6
52" X 30" CLEAR
FLOOR SPACE TO
REFRIG. (CAN
BE OFFSET UP TO
24" OFF THE CL.)
FS-5
52" X 30" CLR.
FLOOR SPACE
PARALLEL
APPROACH
(CENTERED ON
SINK)
5' -1
0"
7'-9"9'-3"3'-0"
'-0
'-0
'-5
/2
20'-0"
'-3
6" 6" 6"
6"
6" 6"
6"
8'-9"11'-3"
A2.1
A2.1
A2.1
A2.1
A3.1
CONC.
SLAB
(NON-LOAD
BEARING)
CONC.
SLAB
(NON-LOAD
BEARING)
3 3
SINK
LINE OF UPPER
CABINETS
ELECTRICAL
PANEL
AND METER
(BACK TO BACK)
A
A
A
A
B
A
AAAA
HVAC INDOOR
UNIT AS REQ'D.
CL
CL
CL CL
CL
A1.2 9A1.2
A3.1
10'-0" 10'-0"
A
FS-1
67" DIA. CLEAR
FLOOR SPACE
FS-2
60" X 56"
APPROACH
TO WATER
CLOSET
FS-4
52" X 30"
CLEAR FLOOR
SPACE TO
LAVATORY
36" MIN
ADA
WC
18"
6"
MAX
"-4
1"
60" CLEAR MIN.
+/- 7'-10 3/4" CLEAR MIN.
18" (15"
MIN CLR.)
NOTE: ALL TOILET ROOM
DIMENSIONS
ARE FROM FACE OF
FINISHED WALL TO FACE
OF FINISHED WALL U.O.N.
FS-3
52" X 30"
SECONDARY
CLEAR FLOOR
SPACE
CL
ADA
TOILET
ROOM
M
IN
M A
X
HORIZONTAL
GRABBARS
SOAP
DISPENSER
TOILET PAPER
DISPENSER
VERTICAL
GRAB BAR
PAPER TOWEL
DISPENSER
WALL HUNG ADA
LAVATORY
COVER HOT WATER
SUPPLY & DRAIN LINES
WITH INSULATION
MIRROR
LINE OF
FINISHED WALL
9' -8
/2
CL
FD
8'
-3
/2
INSULATED
FRAMING FOR
BACKFLOW
PREVENTER, G.C.
TO VERIFY FINAL
SIZE IN THE FIELD
AND PROVIDE
INSULATED
ACCESS PANEL AS
REQ'D. FOR
SERVICE
HEAT PUMP ON
CONCRETE PAD
2'-0"
INSULATED
WALL
A
B B
B B
B
B
B
B
B
D
D
D
D
AE
C
OC
UNRATED TYPICAL EXTERIOR
WALL ASSEMBLY
CEMENT FIBERBOARD SIDING OR APPROVED EQUIV.
SEE ELEVATIONS FOR TYPE AND LOCATION
30 LB BUILDING FELT OR
MFG. RECOMM. EQUIV. WRB PER NC CODE
16" APA RATED PLYWOOD SHEATHING- EXPOSURE 1
2" X 6" WOOD STUD FRAMING @ 16" O.C.
R-15 BATT. INSULATION,
2" GYPSUM WALL BOARD, JOINTS TAPED AND FINISHED
UNRATED 4" INTERIOR
WALL ASSEMBLY
2" GYPSUM WALL BOARD
EACH SIDE, JOINTS TAPED AND FINISHED
2" X 4" WOOD STUDS @ 16" O.C.
W/R-13 BATT INSULATION
UNRATED 6" INTERIOR
WALL ASSEMBLY
2" GYPSUM WALL BOARD
EACH SIDE, JOINTS TAPED AND FINISHED
2" X 4" WOOD STUDS @ 16" O.C.
W/R-15 BATT INSULATION
48" LED SURFACE MOUNTED STRIP LIGHT
A
4" LED WAFER LIGHTB
VANITY BAR LIGHT, DAMP RATEDC
EXTERIOR LED WALLPACK, ADA
COMPLIANT CUTOFF WITH
EMERGENCY BATTERY BACKUP
D
EXHAUST FAN
HVAC SUPPLY
HVAC RETURN
OC OCCUPANCY SENSOR
C
SHEET:
STAMP:
SCALE:
DATE:
DRAWN BY:
ARCHITECTURE + DESIGN, P.L.L.C.
P.O. BOX 1827
KITTY HAWK, NC 27949
PH: (252) 441-6767, FAX (252) 261-6045
BEACON
DRAWING NAME:
ATTENDANT
Beaufort County North Carolina
BUILDING
PROJECT NAME:
CN
2406 Princess Anne Road
Virginia Beach, VA 23456 Phone (757) 563-9027
Facsimile(757) 563-9028
Suite 200
COASTAL
E N G I N E E R I N G
PME ENGINEER:
2026 BEACON ARCHITECTURE + DESIGN
P.L.L.C.- ALL RIGHTS RESERVED
3 / 30 / 26
REVISIONS: DATE:
STRUCTURAL ENGINEER:
RPA ENGINEERING, PE
102 REGENCY BLVD., SUITE A1
GREENVILLE, NORTH CAROLINA
PH: (252) 321-6027
Stilley Station
ISSUED FOR
BID
ISSUE FOR BID
3 / 30 / 26
3 / 30 / 26
SCALE: 12" = 1'-0"
BUILDING FLOOR PLAN
A1.1
BUILDING
PLANS
SCALE: 12" = 1'-0"
REFLECTED CEILING PLAN
GENERAL NOTES:
1. INSPECT AND VERIFY ALL DIMENSIONS ON THE PROJECT AND SITE AS MAY RELATE TO THE EXTENT…