Dwgs_IFP_TCLF_CD_Unit_2_Landfill_Partial_Closure.pdf
PDF 11 MB Posted
- Attached to
- CLASS 2 LANDFILL PARTIAL CLOSURE
- Solicitation number
- RFP #27027
- Issued by
- Greenville County, South Carolina
About this file
This document is a set of contract drawings for the Twin Chimneys Landfill Partial Closure civil project located in Greenville County, South Carolina, prepared by HDR Engineering, Inc. of the Carolinas. The project involves the partial closure construction of Class 2 Unit 2 at the landfill, requiring approximately 301,000 cubic yards of excavation and 120,000 cubic yards of structural fill. The scope of work includes stormwater pond construction, subgrade preparation, perimeter berm structural fill, stone access road installation, and erosion control measures consisting of silt fence, erosion control blankets, and seeding. The drawings are issued for proposals as of October 8, 2026, and include an overall site plan, phase-by-phase grading plans (Phases 1, 2, and 3), technical details, and a skimmer basin specification. The contractor's primary site access is via the main landfill entrance at the scalehouse. The County seeks project substantial completion within 210 calendar days, with the soil borrow area located within the Unit 2 Landfill footprint.
The drawings specify detailed erosion and stormwater control requirements in accordance with the Greenville County Stormwater Design Manual Chapter 8, with particular emphasis on maintaining all erosion control measures to minimize sediment transfer. Key specifications include silt fence installation, reinforced silt fence, rock outlets, and gabion baskets for perimeter protection. Phase 1 includes north grading and east perimeter berm construction with cut/fill data of 108,173 cubic yards cut and 31,608 cubic yards fill (net 76,565 cubic yards). Phase 2 focuses on skimmer basin and associated road construction with 269 cubic yards cut and 10,629 cubic yards fill (net 10,360 cubic yards). Phase 3 encompasses top grading, perimeter road construction, and south/west stormwater channel installation with 192,364 cubic yards cut and 69,449 cubic yards fill (net 122,915 cubic yards). The total denuded area is approximately 35 acres of a 1,140.92-acre site spanning two parcels. The contractor is responsible for security of all tools, materials, and equipment, protection of existing wells, structures, utilities, and maintenance of all erosion and sediment control structures throughout the project duration.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| CLASS_2_LANDFILL_PARTIAL_CLOSURE.pdf | ||
| Specs_IFP_TCLF_CD_Unit_2_Landfill_Partial_Closure.pdf | ||
| COG_Sub_W9_.pdf | ||
| Sample_Services_Agreement.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Twin Chimneys Landfill
Partial Closure Civil
Project No.
11075 Augusta Road
C o n t r a c t D r a w i n g s F o r
10174879
October 2026
I N D E X O F D R A W I N G S
GENERAL
21G-00 COVER SHEET
21G-01 OVERALL SITE PLAN
CIVIL
21C-01 OVERALL GRADING PLAN
21C-02 PHASE 1 GRADING PLAN
21C-03 PHASE 2 GRADING PLAN
21C-04 PHASE 3 GRADING PLAN
21C-05 DETAILS
21C-06 SKIMMER BASIN
Issued for Proposals
Class 2 Unit 2
Greenville County, South Carolina
HDR Engineering, Inc.
of the Carolinas 440 S. Church St., Suite 1200 Charlotte, NC 28202-2075 704.338.6700
10/08/26
0 82
0 74
750 740
0 78
740 745 75
740 73 5 73
0 72 5 72
0 71
660 660
5 76
715 720 725
735 730
725 720
760755
800 805
5 79
0 77
C&D A
CCES
S
ROAD
AC
CE
SS
R
OA
D
73074
75076
740750 760770780790
73073074074074 0750760770
710710710
770 78
0740 750 760 77
0 780
70071
074075
C L
D I T C H
C/ L
DI
TC
H
C/ L
DI
TC
H
C/ L
DI
TC
H
C/ L
DI
TC
H
C/ L
DI
TC
H
C/L
DITC
H
C/L
DI
TCH
DITCH
C/L DI
TCH
DITCH
DI
TC
H
DI
TC
H
DI
TC
H
DI
TC
H
DI
TC
H
DI
TC
H
DI
TC
H
DI
TC
H
DI
TC
H
DI
TC
H
DIT
CH
DITCH
DIT
CH
C/L DITCH
C/L DI
TCH
C/L D
ITCH
C/L D
ITCH
C/L DI
TCH
DITCH
D I T C H
C/ L
DI
TC
H
C/ L
DI
TC
H
C/ L
DI
TC
H
C/ L
DI
TC
H
DI
TC
H
DI
TC
H
DI
TC
H
DI
TC
H
DI
TC
H
DI
TC
H
DI
TC
H
DI
TC
H
DI
TC
H
DI
TC
H
DI
TC
H
DITCH
DITCH
DITCH
DITCH
DIT
CH
DITC
H
DI
TC
H
DI
TC
H
DI
TC
H
DI
TC
H
DI
TC
H
DI
TC
H
DIT
CH
DITC
H
DITC
H
C/ L
DI
TC
H
705710715720725
730 73
74575075575575 575575
5 760760 765765 770770
70571 071572072573073574074575075
81081
780 82
73573573574
077578078
725725725 7307357407
5 77
770775780 785790795
800805810815820
695700705710715
680680
685690
685690
0 86
0 76
0740750
760770780790800810
UNIT 2
C&D
CELL 1
CELL 2
FUTURE
UNIT 7
FUTURE
UNIT 5
CELL 3
CELL 4 CELL 5
ACTIVE
UNIT 4 MSW
CLAY
STOCKPILE
SEDIMENT
BASIN B
SEDIMENT
BASIN C
E-WASTE
METALS
PAD
YARD
WASTE
PAD
SEDIMENT
BASIN A
ROCK
STOCKPILE
17.0 ACRES
8.6 ACRES
COMPOST AREA
8.5 ACRES
10.3 ACRES
SOIL STOCKPILE
8.6 ACRES
UNIT 1 MSW
VA
UL
T
G W -3
1-
LC
-0
1-
LC
-0
1-
LC
-0
1-
LC
-0
1-
LC
-0
1-
LC
-0
1-
LC
-0
1-
LC
-1
1-
LC
-1
1-
LC
-1 2 1-
LC
-1
1-
LC
-1
1-
LC
-1 5 1-
LC
-1
1-
LC
-1
1-
LC
-1
1-
LC
-1
1-
LC
-2
1-
LC
-2
1-
LC
-2
1-
LC
-2
1-
LC
-2
1-
LC
-2
1-
LC
-2
G W -3
G W -3
G W -3 1G W -3
G W -2
G W -1
C S -1
C S -2
VA
UL
T
UGE
UGE
EB
UGE
UGEUGE
UGE
MB
OHW
O
HW
O
HW
LEACHATE
VAULT #1
LP
LP
LP
LP
LP
LP
36"RCP
INV:725.45
"x
"C
M P
INV:728.84
INV:730.90INV:733.21
INV:734.45
GR
GR
x 724.39 TP x 724.90 TP x 7
.0 8 T
P x 7
.4 9 T
P
TP 724.29 x
TP 722.02 x
TP 719.23 x
TP 717.04 x
EB
OUTPARCEL
OUTPARCEL
OUTPARCEL
MM-1
MM-2
MM-3
MM-4
MM-5 MM-6
MM-7
MM-28MM-29
MM-30
MM-31
MM-32
MM-33
MW-4
MW-5
OW-115
MW-72
MW-48
MW-71
MW-47
MW-46
MW-45
MW-70
MW-30
MW-31
MW-32
MW-33
MW-37
MW-38
MW-39
OW-107
OW-108
MW-29
MW-28
MW-27
MW-26
MW-25
MW-66
MW-67
OW-113
OW-114
MW-61
MW-62
MW-24
MW-63
MW-64
MW-65
OW-103
MW-105
MW-13
MW-14
OW-104-R1
M W
-1
7 MW-18
M W
-1
OW-104
OW-105
MW-1
MW-2
MW-3
OW-102
OW-110
OW-109 MW-52
MW-6
MW-7
MW-51
MW-41
MW-12
MW-8
MW-50
MW-11
MW-10
MW-9
OW-101
MW-20
PZ-13s PZ-13d
PZ-44
PZ-7s
PZ-50
PZ-2d PZ-2s
PZ-4a
PZ-76
PZ-6d
PZ-53
PZ-54
PZ-56PZ-6s
PZ-5da PZ-5d
PZ-77
PZ-14
PZ-43
PZ-19
PZ-52s PZ-52d
PZ-7s
PZ-4
PZ-39s PZ-39d
PZ-26d PZ-26s
PZ-23d PZ-23s
PZ-75
PZ-51
PZ-10ra
PZ-41
PZ-57s
PZ-57d
PZ-78
PZ-73
PZ-30
PZ-25 PZ-25d
PZ-20
PZ-64
PZ-29
PZ-79
PZ-55
PZ-67
PZ-66s PZ-66d
PZ-12
PZ-74
PZ-65
PZ-9s
PZ-35d
PZ-35
PZ-62s PZ-62d
PZ-28
PZ-40
PZ-48
OW-105-R1
MW-10R
MW-21
MW-23
MW-22
MW-42
MW-43
MW-44
MW-49
MW-25
6 7 8
OVERALL SITE PLAN
21G-01.dwg
1" = 300' 21G-01
GENERAL NOTES:
1. EXISTING TOPOGRAPHY FROM TWO SEPARATE SURVEYS,FREELAND
& ASSOCIATES AERIAL SURVEY DATED JULY 15, 2021 AND DRONE
SURVEY IN UNIT 1,2 AND 4 AREA BY RP &ASSOCIATES DATED JULY
09, 2025.
2. CONTRACTOR'S PRIMARY ACCESS TO THE SITE SHALL BE VIA THE
MAIN ENTRANCE AT THE LANDFILL SCALEHOUSE.
3. CONTRACTOR RESPONSIBLE FOR SECURITY OF ALL TOOLS,
MATERIALS AND EQUIPMENT LEFT ON SITE. CONTRACTOR TO
SECURE ACCESS POINTS TO THE WORK SITE AS NECESSARY.
4. THE CONTRACTOR SHALL PROTECT ALL EXISTING WELLS,
STRUCTURES AND UTILITIES. ANY WELLS, STRUCTURES OR
UTILITIES THAT ARE DAMAGED SHALL BE REPLACED OR REPAIRED
(AS DIRECTED BY OWNER).
5. EROSION AND STORMWATER CONTROL MEASURES ARE INSTALLED
AND OPERATIONAL FOR THE DESIGNATED WORK AREAS.
CONTRACTOR TO MAINTAIN AND PROTECT THE STRUCTURES FROM
DAMAGE.
6. SITE BENCHMARK CONTROL IS LOCATED NEAR THE CELLULAR
TOWER.
CONSTRUCTION AREA
BORINGS (SB & B)
METHANE MONITORING (MM)
PIEZOMETER (PZ)
MONITORING AND OBSERVATION
WELL (MW,OW)
PROPOSED EXISTING ABANDONED
MW-P
MM-P
PL
LEGEND
EXISTING 2021 & 2025 MAJOR CONTOURS
EXISTING 2021 & 2025 MINOR CONTOURS
WETLANDS
UNIT AND CELL BASELINES
PROPERTY LINE
EXISTING TREELINE
PZ-# PZ-#
B-#B-#
MM-#
MW-A
SEDIMENT
BASIN #T2
SEDIMENT
BASIN #T5
SEDIMENT
BASIN #T3
SEDIMENT BASIN #9
WETLANDS
SEDIMENT BASIN #10
DI #9
LEACHATE
TANKS
SCALE
HOUSE
ADMINISTRATION
BUILDING
EDUCATION
BUILDING
CELLULAR
TOWER
SEDIMENT
TRAP A
SEDIMENT
BASIN #T4
EXISTING CONSTRUCTION ENTRANCE
AUGUSTA RD
AUGUSTA RD
BRIDGE ROAD
SEDIMENT BASIN #11
100 YEAR FLOODPLAIN
LEACHATE
EVAPORATOR
CONCRETE
MONUMENT
N 987685.471 E 1604817.497
EL. 809.25
STOCKPILE ACCESS ROAD
(SEE SHEET 12C-03)
TEMPORARY
SEDIMENT BASIN A
LIMITS OF SURVEY
LIMITS OF SURVEY
A
B
C
2 3 4 5 6 7 8
D
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
0 1" 2" FILENAME
SCALE
SHEET
DATE
UNIT 2 PARTIAL CLOSURE
Greenville County South Carolina10174879
P. WESTMORELAND, P.E.
0 10/2026 ISSUED FOR PROPOSALS
HDR Engineering Inc.
440 S. Church St. Suite 1200 Charlotte, NC 28202-2075 704.338.6700 of the Carolinas
PROJECT ENGINEER
DRAWN BY
MM-28
MM-32
MM-33
MW-52
MW-51
MW-41
MW-8
MW-50
PZ-7s
PZ-19
PZ-39s
PZ-39d
PZ-26d PZ-26s
PZ-28
PZ-40
PZ-48
MW-42
MW-43
MW-44
MW-49
SF
SF
SF
SF
SF SF
SF SF SF
SF
SF SF SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
A
B
C
2 3 4 5 6 7 8
D
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
0 1" 2" FILENAME
SCALE
SHEET
DATE
UNIT 2 PARTIAL CLOSURE
Greenville County South Carolina10174879
P. WESTMORELAND, P.E.
0 10/2026 ISSUED FOR PROPOSALS
HDR Engineering Inc.
440 S. Church St. Suite 1200 Charlotte, NC 28202-2075 704.338.6700 of the Carolinas
PROJECT ENGINEER
DRAWN BY
OVERALL GRADING PLAN
21C-01.dwg
1" = 100' 21C-01
PL
LEGEND
EXISTING 2025 MAJOR CONTOURS
EXISTING 2025 MINOR CONTOURS
WETLANDS
UNIT AND CELL BASELINES
PROPERTY LINE
EXISTING TREELINE
PROPOSED MAJOR CONTOURS
PROPOSED MINOR CONTOURS
SFSFSFSF SILT FENCE
REINFORCED SILT
FENCE
SILT FENCE ROCK
OUTLET
GABION BASKETS
PERIMETER ROAD
21C-05
21C-05
21C-05
21C-05
21C-05
GENERAL CONSTRUCTION SEQUENCE:
1. ESTABLISH LIMITS OF CONSTRUCTION.
2. PERFORM INITIAL SURVEY OF THE CONSTRUCTION AREA TO
ESTABLISH BASIS FOR PAY QUANTITIES.
3. INSTALL SILT FENCE.
4. BEGIN PHASE 1 OF CONSTRUCTION. PHASE 1 INCLUDES
GRADING IN NORTH, CONSTRUCTION OF EAST SECTION OF
PERIMETER BERM AND STORMWATER CHANNELS AS SHOWN ON
DRAWING 21C-02.
5. AFTER COMPLETION OF PHASE 1 BEGIN THE PHASE 2
CONSTRUCTION. PHASE 2 INCLUDES CONSTRUCTION OF
SKIMMER BASIN, GRADING AND ROAD AROUND THE SKIMMER
BASIN AS SHOWN ON DRAWING 21C-03.
6. AFTER COMPLETION OF PHASE 2 BEGIN THE PHASE 3
CONSTRUCTION. PHASE 3 INCLUDES GRADING ON TOP,
CONSTRUCTION OF PERIMETER ROAD AND STORMWATER
CHANNEL ON SOUTH AND WEST AS SHOWN ON DRAWING 21C-04.
7. INSTALL THE PERIMETER ROAD GEOTEXTILE AND STONE.
8. PERFORM SEEDING OF THE EXTERIOR AND INTERIOR SLOPES.
9. UPON COMPLETION OF GRADING PERFORM ASBUILT
SURVEY OF THE CONSTRUCTION AREA AND THE
STOCKPILE. SURVEYS WILL BE USED FOR FINAL PAYMENT.
BORINGS (SB & B)
METHANE MONITORING (MM)
PIEZOMETER (PZ)
MONITORING AND
OBSERVATION WELL (MW,OW)
PROPOSED EXISTING ABANDONED
MW-P
MM-P
PZ-#
B-#
PZ-#
B-#
MM-#
MW-A
MW-51
MW-41
MW-50
PZ-7s
PZ-39s
PZ-39d
PZ-26d PZ-26s
PZ-51
PZ-57s
57d
PZ-40
PZ-48
MW-42
MW-43
MW-44
MW-49
SF
SF
SF
SF
SF SF
SF SF SF
SF
SF SF SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
A
B
C
2 3 4 5 6 7 8
D
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
0 1" 2" FILENAME
SCALE
SHEET
DATE
UNIT 2 PARTIAL CLOSURE
Greenville County South Carolina10174879
P. WESTMORELAND, P.E.
0 10/2026 ISSUED FOR PROPOSALS
HDR Engineering Inc.
440 S. Church St. Suite 1200 Charlotte, NC 28202-2075 704.338.6700 of the Carolinas
PROJECT ENGINEER
DRAWN BY
PHASE 1
GRADING PLAN
21C-02.dwg
1" = 100' 21C-02
PL
LEGEND
EXISTING 2025 MAJOR CONTOURS
EXISTING 2025 MINOR CONTOURS
WETLANDS
UNIT AND CELL BASELINES
PROPERTY LINE
EXISTING TREELINE
PROPOSED MAJOR CONTOURS
PROPOSED MINOR CONTOURS
CUT/FILL DATA
CUT (CY) 108,173
FILL (CY) 31,608
NET (CY) 76,565
SFSFSFSF SILT FENCE
PERIMETER ROAD
21C-05
21C-05
BORINGS (SB & B)
METHANE MONITORING (MM)
PIEZOMETER (PZ)
MONITORING AND OBSERVATION
WELL (MW,OW)
PROPOSED EXISTING ABANDONED
MW-P
MM-P
PZ-#
B-#
PZ-#
B-#
MM-#
MW-A
MW-8
MW-50
PZ-7s
PZ-39s
PZ-39d
PZ-26d PZ-26s
PZ-51
PZ-57s
PZ-40
PZ-48
MW-42
MW-43
MW-44
MW-49
SF
SF
SF
SF
SF SF
SF SF SF
SF
SF SF SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
A
B
C
2 3 4 5 6 7 8
D
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
0 1" 2" FILENAME
SCALE
SHEET
DATE
UNIT 2 PARTIAL CLOSURE
Greenville County South Carolina10174879
P. WESTMORELAND, P.E.
0 10/2026 ISSUED FOR PROPOSALS
HDR Engineering Inc.
440 S. Church St. Suite 1200 Charlotte, NC 28202-2075 704.338.6700 of the Carolinas
PROJECT ENGINEER
DRAWN BY
PHASE 2
GRADING PLAN
21C-03.dwg
1" = 100' 21C-03
PL
LEGEND
EXISTING 2025 MAJOR CONTOURS
EXISTING 2025 MINOR CONTOURS
WETLANDS
UNIT AND CELL BASELINES
PROPERTY LINE
EXISTING TREELINE
PROPOSED MAJOR CONTOURS
PROPOSED MINOR CONTOURS
CUT/FILL DATA
CUT (CY) 269
FILL (CY) 10,629
NET (CY) 10,360
SEDIMENT BASIN
EMERGENCY SPILLWAY
SFSFSFSF SILT FENCE
21C-06
21C-06
BORINGS (SB & B)
METHANE MONITORING (MM)
PIEZOMETER (PZ)
MONITORING AND OBSERVATION
WELL (MW,OW)
PROPOSED EXISTING ABANDONED
MW-P
MM-P
PZ-#
B-#
PZ-#
B-#
MM-#
MW-A
POROUS BAFFLES 5
21C-06
MW-8
MW-50
PZ-7s
PZ-39s
PZ-39d
PZ-26d PZ-26s
PZ-51
PZ-57s
PZ-40
PZ-48
MW-42
MW-43
MW-44
MW-49
SF
SF
SF
SF
SF SF
SF SF SF
SF
SF SF SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
A
B
C
2 3 4 5 6 7 8
D
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
0 1" 2" FILENAME
SCALE
SHEET
DATE
UNIT 2 PARTIAL CLOSURE
Greenville County South Carolina10174879
P. WESTMORELAND, P.E.
0 10/2026 ISSUED FOR PROPOSALS
HDR Engineering Inc.
440 S. Church St. Suite 1200 Charlotte, NC 28202-2075 704.338.6700 of the Carolinas
PROJECT ENGINEER
DRAWN BY
PHASE 3
GRADING PLAN
21C-04.dwg
1" = 100' 21C-04
PL
LEGEND
EXISTING 2025 MAJOR CONTOURS
EXISTING 2025 MINOR CONTOURS
WETLANDS
UNIT AND CELL BASELINES
PROPERTY LINE
EXISTING TREELINE
PROPOSED MAJOR CONTOURS
PROPOSED MINOR CONTOURS
CUT/FILL DATA
CUT (CY) 192,364
FILL (CY) 69,449
NET (CY) 122,915
SFSFSFSF SILT FENCE
GABION BASKETS
PERIMETER ROAD
21C-05
21C-05
21C-05
BORINGS (SB & B)
METHANE MONITORING (MM)
PIEZOMETER (PZ)
MONITORING AND OBSERVATION
WELL (MW,OW)
PROPOSED EXISTING ABANDONED
MW-P
MM-P
MW-A
B-#
PZ-#
MM-#
B-#
PZ-#
SUBGRADE
C
1/8"/FT. 1/8"/FT.
10.0' 4.0' 2.0' 4.0' 30.0' VARIES 12.0'
12.0'
MIN
24.0'
2 1
PERIMETER DITCH
L PERIMETER ROAD
EXTERIOR
CHANNEL
PERIMETER
BERM
ACCESS
ROAD
LANDFILL
WOVEN
GEOTEXTILE
12" STONE
EROSION
CONTROL
BLANKET
EROSION
CONTROL
BLANKET
12.0'
EROSION
CONTROL
BLANKET
SILT FENCE ROCK OUTLET
South Carolina Department of Health and Environmental Control
DATE
MEDIAN 8" DIA.
RIP-RAP
1'-0"1'-0"
A
A
3'-0" MIN.
30"
TOP OF FENCE
AASHTO #57 STONE
FACE ON UPSTREAM SIDE
1.5
1 (MAX) 1 (MAX)
1.55/6 H
6" MIN. THICKNESS
AASHTO #57 STONE
FACE ON UPSTREAM SIDE1.5
1 (MAX) 1 (MAX)
1.5
FLOW
MEDIAN 8" DIA.
RIP-RAP
SILT FENCE ROCK OUTLET
ELEVATION - UP-SLOPE FACE
SECTION A-A
FLAT-BOTTOM TRENCH DETAIL V-SHAPED TRENCH DETAIL
FABRIC ATTACHMENT DETAIL
SILT FENCE INSTALLATION
January, 2013
STANDARD DRAWING NO.
APPROVED BY:
GREENVILLE COUNTY STORM WATER MANAGEMENT DATE
Greenville County Storm Water Management
SURGE STONE
PERIMETER
ROAD
EXTERIOR
CHANNEL
ACCESS ROAD
2H:1V2H:1V
ACCESS
ROAD
PERIMETER
ROAD
SIDE VIEW
TOP VIEW
2H:1V2H:1V
4H:1V4H:1V
.5
FLOW
6 - 9'Lx4.5'Wx3'H GABION
BASKETS
3 - 6'Lx4.5'Wx3'H GABION
BASKETS
A
B
C
2 3 4 5 6 7 8
D
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
0 1" 2" FILENAME
SCALE
SHEET
DATE
UNIT 2 PARTIAL CLOSURE
Greenville County South Carolina10174879
P. WESTMORELAND, P.E.
0 10/2026 ISSUED FOR PROPOSALS
HDR Engineering Inc.
440 S. Church St. Suite 1200 Charlotte, NC 28202-2075 704.338.6700 of the Carolinas
PROJECT ENGINEER
DRAWN BY
DETAILS
21C-05.dwg
AS SHOWN 21C-05
1. ALL EROSION CONTROL MEASURES SHALL BE IN STRICT ACCORDANCE WITH LOCAL AND STATE STANDARDS - SPECIFICALLY
THE GREENVILLE COUNTY STORMWATER DESIGN MANUAL CHAPTER 8.
2. THE CONTRACTOR SHALL DILIGENTLY AND CONTINUOUSLY MAINTAIN ALL EROSION CONTROL BMPs AND STRUCTURES TO ENSURE DEVICES ARE FUNCTIONING PROPERLY TO MINIMIZE EROSION AND SEDIMENT TRANSFER. ALL EROSION AND SEDIMENT CONTROLS SHALL BE INSPECTED AT LEAST ONCE EVERY SEVEN CALENDAR DAYS, OR AFTER ANY STORM EVENT
THE PRODUCES GREATER THAN ½-INCHES OF RAINFALL DURING ANY 24-HOUR PERIOD.
3. THE TOTAL DENUDED AREA (LIMITS OF DISTURBANCE) IS APPROXIMATELY 35 ACRES.
4. THE TOTAL SITE ACREAGE IS 1140.92 ACRES. THIS WORK OCCURS IN PARCELS (PID #0580010100500 AND 0590010101300)
5. THE SOIL CLASSIFICATION IS PREDOMINANTLY: PACOLET (PdD2, PcE) AND CECIL (CeD, CIB2)
6. THE LOCATION OF EXISTING TREE PROTECTION FENCE, SILT FENCE, DIVERSION DITCHES, ETC. MAY HAVE BEEN ADJUSTED FROM LOCATIONS SHOWN IN THE DESIGN PLANS. FIELD VERIFY AND ACCOMMODATE EXISTING LOCATIONS ACCORDINGLY.
7. ADDITIONAL EROSION CONTROL DEVICES MAY BE REQUIRED DUE TO FIELD CONDITIONS, AS DIRECTED BY THE INSPECTOR, AND BASED ON CONTRACTOR SEQUENCE OF OPERATIONS.
8. ENCOMPASS STAGING AREAS AND MATERIAL STOCKPILES WITH SILT FENCE EXCEPT FOR THE POINTS OF ACCESS.
9. MAINTAIN SITE GRADING DURING CONSTRUCTION TO CONTROL RUNOFF WITH STORMWATER AND SEDIMENT CONTROL
FEATURES.
10. STABILIZATION IS THE BEST FORM OF EROSION CONTROL. PROVIDE TEMPORARY SEEDING AS NECESSARY TO ENSURE DENUDED AREAS ARE INDIVIDUALLY LESS THAN 10 ACRES AND LESS THAN 20 ACRES IN TOTAL AT ANY ONE TIME.
11. ALL PERIMETER DIKES, SWALES, DITCHES, PERIMETER SLOPES AND ALL SLOPES STEEPER THAN 3:1 SHALL BE PROVIDED TEMPORARY OR PERMANENT STABILIZATION WITH GROUND COVER AS SOON AS PRACTICABLE BUT IN ANY EVENT WITHIN 7 CALENDAR DAYS FROM THE LAST LAND-DISTURBING ACTIVITY. ALL OTHER DISTURBED AREAS SHALL BE PROVIDED TEMPORARY OR PERMANENT STABILIZATION WITH GROUND COVER AS SOON AS PRACTICABLE BUT IN ANY EVENT WITHIN 14
CALENDAR DAYS FROM THE LAST LAND-DISTURBING ACTIVITY.
12. TEMPORARY STABILIZATION MEASURES. WHERE CONSTRUCTION OR LAND DISTURBANCE ACTIVITY WILL OR HAS TEMPORARILY CEASED ON ANY PORTION OF A SITE, TEMPORARY SITE STABILIZATION MEASURES SHALL BE REQUIRED AS SOON AS
PRACTICABLE, BUT NO LATER THAN 14 CALENDAR DAYS AFTER THE ACTIVITY HAS CEASED.
13. IN ANY EVENT, SLOPES LEFT EXPOSED WILL, WITHIN 21 CALENDAR DAYS OF ANY PHASE OF GRADING, BE PLANTED OR OTHERWISE PROVIDED WITH TEMPORARY OR PERMANENT GROUND COVER, DEVICES, OR STRUCTURES SUFFICIENT TO
RESTRAIN EROSION.
14. ALL MATERIALS REQUIRED FOR CONSTRUCTION OF SEDIMENTATION AND EROSION CONTROL MEASURES SHALL BE AVAILABLE
ON SITE BEFORE ANY LAND DISTURBING ACTIVITY IS BEGUN.
15. SEDIMENT TRACKING CONTROL. STABILIZED CONSTRUCTION ENTRANCES SHALL BE LOCATED AND UTILIZED AT ALL POINTS OF INGRESS/EGRESS ON A CONSTRUCTION SITE. PREVENT THE TRANSFER OF SOIL, MUD AND DUST ONTO PUBLIC RIGHTS-OF-WAYS. REMOVE ALL MATERIALS TRACKED OR OTHERWSIE DEPOSITED ON THE PUBLIC RIGHT OF WAY.
16. CROSSINGS OF WATERWAYS DURING CONSTRUCTION IS NOT ALLOWED. DO NOT ENCROACH INTO STREAM BUFFERS, RIPARIAN
AREAS AND WETLANDS.
17. EXCAVATED SOIL SHALL BE STOCKPILED AND PRESERVED FROM EROSION OR DISPERSAL BOTH DURING AND AFTER SITE
GRADING OPERATIONS.
18. FINAL STABILIZATION OF THE SITE IS REQUIRED WITHIN 14 CALENDAR DAYS OF CONSTRUCTION COMPLETION.
19. TEMPORARY STRUCTURAL CONTROLS INSTALLED DURING CONSTRUCTION SHALL BE DESIGNED TO ACCOMPLISH MAXIMUM STABILIZATION AND CONTROL OF EROSION AND SEDIMENTATION, AND SHALL BE INSTALLED, MAINTAINED, AND REMOVED ACCORDING TO THE SPECIFICATIONS SET FORTH IN THE DESIGN MANUAL, STANDARD SPECIFICATIONS AND STANDARD DRAWINGS. ALL TEMPORARY STRUCTURAL CONTROLS SHALL BE DESIGNED TO CONTROL THE PEAK RUNOFF RESULTING FROM THE STORM EVENT IDENTIFIED IN THE DESIGN MANUAL, STANDARD SPECIFICATIONS AND STANDARD DRAWINGS.
GENERAL NOTES
NOT TO SCALE
PERIMETER ROAD3
21C-01
NOT TO SCALE
GABION BASKETS4
21C-01
NOT TO SCALE
SILT FENCE ROCK OUTLET2
21C-01NOT TO SCALE
REINFORCED SILT FENCE1
21C-01
STAKE TO
SUPPORT WIRE
SUPPORT ROPE
TO WIRE TO
PREVENT SAGGING
4'MAX
SUPPORT POST
24" INTO BOTTOM
OR SIDES
DESIGN LIFE OF FABRIC
IS 6-12 MONTHS
COIR MESH OR JUTE, TRENCHED
INTO BOTTOM AND SIDE
BAFFLE DETAIL
3'min
DESIGN NOTES:
1. USE MATTING MADE OF 700 G/M2 100% COCONUT FIBER (COIR) TWINE WOVEN INTO HIGH STRENGTH MATRIX
WITH THE PROPERTIES SHOWN IN TABLE.
2. STAPLES SHOULD BE MADE OF 0.125 INCH DIAMETER NEW STEEL WIRE FORMED INTO A ‘U’ SHAPE NOT LESS THAN 12 INCHES IN LENGTH WITH A THROAT OF 1 INCH IN WIDTH. THE STAPLES ANCHOR THE POROUS
BAFFLES INTO THE SIDES AND BOTTOM OF THE BASIN.
3. ENSURE THAT STEEL POSTS FOR POROUS BAFFLES ARE OF A SUFFICIENT HEIGHT TO SUPPORT BAFFLES AT DESIRED HEIGHT. POSTS SHOULD BE APPROXIMATELY 1-3/8” WIDE MEASURED PARALLEL TO THE FENCE, AND HAVE A MINIMUM WEIGHT OF 1.25 LB/LINEAR FT. THE POSTS MUST BE EQUIPPED WITH AN ANCHOR PLATE HAVING A MINIMUM AREA OF 14.0 SQUARE INCHES AND BE OF THE SELF-FASTENER ANGLE STEEL TYPE TO HAVE A MEANS OF RETAINING WIRE AND COIR FIBER MAT IN THE DESIRED POSITION WITHOUT
DISPLACEMENT.
4. USE 9-GAUGE HIGH TENSION WIRE FOR SUPPORT WIRE.
5. THE DESIGN LIFE OF THE FABRIC IS 6-12 MONTHS, BUT MAY NEED TO BE REPLACED MORE OFTEN IF
DAMAGED OR CLOGGED.
BAFFLE (TYP.)
INLET FLOW
EARTHEN EMBANKMENT
5' CREST WIDTH
INLET ZONE
35% OF SURFACE AREA
FIRST CHAMBER
25% OF SURFACE AREA
SECOND CHAMBER
25% OF SURFACE AREA
OUTLETINLET
PERSPECTIVE VIEW
TOP VIEW
EXTEND BAFFLES UP SIDES AS
TO NOT ALLOW FLOW AROUND
THE ENDS.
OUTLET ZONE
15% OF SURFACE
AREA
MAINTENANCE:
REPAIR/REPLACE BAFFLES WHEN THEY
COLLAPSE, TEAR OR DECOMPOSE.
REMOVE SEDIMENT WHEN CELL IS 1 / 2 FULL./
CROSS SECTIONAL VIEW
WATER LEVEL
TRASH RACK
COMPACTED EARTHEN DAM
SKIMMER
INSTALLATION NOTES:
1. CLEAR, GRUB, AND STRIP THE AREA UNDER THE EMBANKMENT OF ALL VEGETATION AND ROOT MAT. REMOVE ALL SURFACE SOIL CONTAINING HIGH AMOUNTS OF ORGANIC MATTER AND STOCKPILE OR DISPOSE OF IT PROPERLY. HAUL ALL OBJECTIONABLE MATERIAL TO THE DESIGNATED DISPOSAL AREA. PLACE TEMPORARY SEDIMENT CONTROL MEASURES BELOW BASIN AS NEEDED.
2. SELECT FILL SHALL BE USED TO CONSTRUCT THE BASIN.
3. ENSURE THAT FILL MATERIAL FOR THE EMBANKMENT IS FREE OF ROOTS, WOODY VEGETATION, ORGANIC MATTER, AND OTHER OBJECTIONABLE MATERIAL. PLACE THE FILL IN LIFTS NOT TO EXCEED 8
INCHES, AND MACHINE COMPACT IT TO 95% STANDARD PROCTOR.
4. SHAPE THE BASIN TO THE SPECIFIED DIMENSIONS. PREVENT THE SKIMMING DEVICE FROM SETTLING INTO THE MUD BY EXCAVATING A SHALLOW PIT UNDER THE SKIMMER OR PROVIDING A LOW SUPPORT
UNDER THE SKIMMER OF STONE OR TIMBER.
5. EXCAVATE A CUT-OFF TRENCH AT THE CENTERLINE OF THE EMBANKMENT FILL AREA AT A MINIMUM DEPTH AND WIDTH OF 2 FEET WITH 1:1 SIDE SLOPES. ENSURE THAT THE TRENCH IS IN UNDISTURBED
SOIL AND EXTENDS THROUGH THE LENGTH OF THE EMBANKMENT TO THE ELEVATION OF THE RISER CREST AT EACH END. THE CUT-OFF TRENCH SHOULD BE COMPACTED IN 8 INCH LIFTS TO 95%.
6. PLACE THE BARREL ON A FIRM, SMOOTH FOUNDATION OF IMPERVIOUS SOIL. DO NOT USE PERVIOUS MATERIAL SUCH AS SAND, GRAVEL, OR CRUSHED STONE AS BACKFILL AROUND THE PIPE. PLACE THE
FILL MATERIAL AROUND THE PIPE SPILLWAY IN 4-INCH LAYERS AND COMPACT IT UNDER AND AROUND THE PIPE TO AT LEAST THE SAME DENSITY AS THE ADJACENT EMBANKMENT. CARE MUST BE TAKEN NOT TO RAISE THE PIPE FROM THE FIRM CONTACT WITH ITS FOUNDATION WHEN COMPACTING UNDER THE PIPE HAUNCHES. PLACE A MINIMUM DEPTH OF 2 FEET OF COMPACTED BACKFILL OVER THE PIPE SPILLWAY BEFORE CROSSING IT WITH CONSTRUCTION EQUIPMENT. IN NO CASE SHOULD THE PIPE CONDUIT BE INSTALLED BY CUTTING A TRENCH THROUGH THE DAM AFTER THE EMBANKMENT IS
COMPLETE.
7. ASSEMBLE THE SKIMMER FOLLOWING THE MANUFACTURERS INSTRUCTIONS.
8. LAY THE ASSEMBLED SKIMMER ON THE BOTTOM OF THE BASIN WITH THE FLEXIBLE JOINT AT THE INLET OF THE BARREL PIPE. ATTACH THE FLEXIBLE JOINT TO THE BARREL PIPE AND POSITION THE
SKIMMER OVER THE EXCAVATED PIT OR SUPPORT. BE SURE TO ATTACH A ROPE TO THE SKIMMER AND ANCHOR IT TO THE SIDE OF THE BASIN. THIS WILL BE USED TO PULL THE SKIMMER TO THE SIDE
FOR MAINTENANCE.
9. EARTHEN SPILLWAYS—INSTALL THE SPILLWAY IN UNDISTURBED SOIL TO THE GREATEST EXTENT POSSIBLE. THE ACHIEVEMENT OF PLANNED ELEVATIONS, GRADE, DESIGN WIDTH, AND ENTRANCE AND EXIT CHANNEL SLOPES ARE CRITICAL TO THE SUCCESSFUL OPERATION OF THE SPILLWAY. THE SPILLWAY SHOULD BE LINED WITH RIPRAP AS INDICATED.
10. INLETS—DISCHARGE WATER INTO THE BASIN IN A MANNER TO PREVENT EROSION. USE TEMPORARY SLOPE DRAINS OR DIVERSIONS WITH OUTLET PROTECTION TO DIVERT SEDIMENT-LADEN WATER TO
THE UPPER END OF THE POOL AREA TO IMPROVE BASIN TRAP EFFICIENCY.
11. EROSION CONTROL—CONSTRUCT THE STRUCTURE SO THAT THE DISTURBED AREA IS MINIMIZED. DIVERT SURFACE WATER AWAY FROM BARE AREAS. COMPLETE THE EMBANKMENT BEFORE THE AREA IS CLEARED. STABILIZE THE EMERGENCY SPILLWAY EMBANKMENT AND ALL OTHER DISTURBED AREAS ABOVE THE CREST OF THE PRINCIPAL SPILLWAY IMMEDIATELY
AFTER CONSTRUCTION.
12. INSTALL POROUS BAFFLES AS SPECIFIED IN DETAIL.
13. AFTER ALL THE SEDIMENT-PRODUCING AREAS HAVE BEEN PERMANENTLY STABILIZED, REMOVE THE STRUCTURE AS INDICATED ON THE DRAWINGS
AND ALL THE UNSTABLE SEDIMENT. SMOOTH THE AREA TO BLEND WITH THE ADJOINING AREAS AND STABILIZE PROPERLY.
SEDIMENT BASIN ANTIFLOTATION BLOCK ANTI-SEEP COLLAR
SEDIMENT
BASIN ID
RISER
HEIGHT
(FT.)
RISER DIA.
(IN.)
BARREL DIA.
(IN.)
LENGTH
(IN.)
WIDTH
(IN.)
HEIGHT
(IN.)
NO. OF
COLLARS
COLLAR
SIZE (FT.)
COLLAR
PROJECTION
(FT.)
COLLAR
SPACING
(FT.)
1 3.75 48 36 60 60 12 2 6'X6' 3.50 25
ANTI-SEEP
COLLARS
EMERGENCY SPILLWAY
RIPRAP INLET AND OUTLET TABLE
OUTLET ID D50 (FT) APRON THICKNESS
(FT) A (IN) B (FT) L (FT) W (FT)
BASIN 1 0.50 0.75 36 9 20 23
POROUS BAFFLES
NOT TO SCALE
21C-03
NOTES:
1. 3 BAFFLES (MIN) BETWEEN INLET & OUTLET.
2. SEE N.C. DENR EROSION and SEDIMENT CONTROL
PLANNING and DESIGN MANUAL FOR CONDITIONS
WHERE PRACTICE APPLIES; PLANNING
CONSIDERATION & DESIGN CRITERIA.
OUTLET , SEE DETAIL
RIPRAP OUTLET PROTECTION
NOT TO SCALE
21C-06
END OF APRON
LAYER OF WOVEN
GEOTEXTILE FILTER FABRIC
(A) - PIPE DIAMETER (MULTIPLE
PIPES IN SOME LOCATIONS)
SEDIMENT BASIN
NOT TO SCALE
21C-03
NOTES:
1. SKIMMER WILL BE PROVIDED BY THE OWNER. CONTRACTOR TO INSTALL
PER MANUFACTURERS RECCOMENDATIONS.
RETRIEVAL
ROPE
PLAN VIEW
SIDE VIEW
PVC 90°
ELBOW (TYP.)
FLOTATION
SECTION
PVC END
CAP (TYP.)
PVC PIPE (TYP.)
HDPE FLEXIBLE DRAIN
PIPE PER MANUFACTURER
PVC TEE
SKIMMER SECTION
OVERLAPPING
CONNECTING BANDS
SKIMMER
NOT TO SCALE
21C-06
PVC VENT PIPE
CROSS SECTION OF RIPRAP
SPILLWAY AT CONTROL SECTION
PROFILE ALONG CENTERLINE
OF RIPRAP SPILLWAY
SEDIMENT
BASIN ID
MINIMUM
WIDTH (FT.)
(b)
RIPRAP LAYER
THICKNESS (IN.)
RIPRAP
D50 (IN.)
RIPRAP DMAX
(IN.)
1 20 12 8 12 b
EMERGENCY SPILLWAY
NOT TO SCALE
21C-03
LEGEND
b = BOTTOM WIDTH OF EARTH SPILLWAY AT THE CONTROL SECTION, IN FEET.
WOVEN GEOTEXTILE
4" FAIRCLOTH OR
EQUIVALENT
POND BOTTOM EL. 44
1" STEEL STRAP (TYP.)
ORIFICE PLATE
PVC TEE
RISER IS 48" DIA., 16
GAUGE CORRUGATED
METAL PIPE (CMP)
BARREL IS 36" DIA., 16 GAUGE
CORRUGATED METAL PIPE (CMP)
ANTI-FLOTATION BLOCK
(3,000 PSI CONCRETE)
CONCRETE
INFILL TO DRAIN
CUT-OFF TRENCH (2' DEEP,
2' WIDE, 1:1 SIDE SLOPES)
21C-06
RIPRAP OUTLET
PROTECTION
21C-06
B
W
10 MIN.
L
6"x36" ORIFICE
21C-06
21C-06
CYLINDER IS 16 GAUGE
NOTE:
CORRUGATED METAL PIPE.
ISOMETRIC DETAIL
WELDED
TRASH GUARDTACK WELD
ALL AROUND
12" SPACE BAR (TYP.)
SAME MATERIAL AS
SUPPORT BAR
ACCMP RISER,
W/ 2 2/3"X1/2" CORRUGATIONS
SUPPORT BAR SIZE
#8 REBAR
OR EQUAL
8" MIN
25" TALL
72" Ø
16 GAUGE METAL
1. THE CYLINDER MUST BE FIRMLY FASTENED
TO THE TOP OF THE RISER.
2. SUPPORT BARS ARE WELDED TO THE TOP
OF THE RISER OR ATTACHED BY STRAPS
BOLTED TO THE TOP OF THE RISER.
TRASH RACK
NOT TO SCALE
21C-06
A
B
C
2 3 4 5 6 7 8
D
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
0 1" 2" FILENAME
SCALE
SHEET
DATE
UNIT 2 PARTIAL CLOSURE
Greenville County South Carolina10174879
P. WESTMORELAND, P.E.
0 10/2026 ISSUED FOR PROPOSALS
HDR Engineering Inc.
440 S. Church St. Suite 1200 Charlotte, NC 28202-2075 704.338.6700 of the Carolinas
PROJECT ENGINEER
DRAWN BY
SKIMMER BASIN
21C-06.dwg
AS SHOWN 21C-06
File details come from the government source that posted it. Updated .