DWG_FINAL_Bldg 730_Interior Demolition.pdf

PDF 1 MB Posted

Attached to
Building 730 Interior Demolition Federal contract opportunity
Solicitation number
W911SG22B0007
Issued by
Department of the Army Materiel Command Mission and Installation Contracting Command Fort Hood

View the file

Other files for this federal contract opportunity

Show all 12

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

T50

T48

T45

T4

T

801B

SUMNER ROAD

CHAFFEE ROAD

H O

LB

R

O O

K A

V E

C U

ST

ER

R O

A D

D E S C R

IP

TI

O N

M A R K

D A

TE

D P

W

FO

R T

B

LI

SS

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DESIGNED BY:

AutoCAD SHX Text

SPEC. #

AutoCAD SHX Text W.O. #

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

NUMBER:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

OF

AutoCAD SHX Text

DIRECTORATE OF PUBLIC WORKS FORT BLISS, TEXAS

AutoCAD SHX Text

BUILDING 1006 REPLACE AIR WASHERS

AutoCAD SHX Text

COVER SHEET

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text A-100

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AS SHOWN

AutoCAD SHX Text

FORT BLISS, TEXAS

AutoCAD SHX Text

INDEX OF DRAWINGS

AutoCAD SHX Text

NO.

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

BUILDING 730 INTERIOR DEMOLITION

AutoCAD SHX Text

PROJECT LOCATION MAP

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text N

AutoCAD SHX Text

PROJECT LOCATION

AutoCAD SHX Text A-100 = COVER SHEET/SITE LOCATION MAP A-101 = FLOOR LAYOUT AD-102 = CEILING & WALLS DEMOLITION MD-100 = MECHANICAL DEMOLITION ED-100 = ELECTRICAL DEMOLITION E-100 = REMAINING LIGHTS & POWER

AutoCAD SHX Text A.H

AutoCAD SHX Text

FE-XXXXX-2J

AutoCAD SHX Text A.H

AutoCAD SHX Text

AutoCAD SHX Text 12/14/2021

D E S C R

IP

TI

O N

M A R K

D A

TE

D P

W

FO

R T

B

LI

SS

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 103-A

AutoCAD SHX Text 103-B

AutoCAD SHX Text 103-D

AutoCAD SHX Text 103-C

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DESIGNED BY:

AutoCAD SHX Text

SPEC. #

AutoCAD SHX Text W.O. #

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

NUMBER:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

OF

AutoCAD SHX Text

DIRECTORATE OF PUBLIC WORKS FORT BLISS, TEXAS

AutoCAD SHX Text

BUILDING 730 INTERIOR DEMOLITION

AutoCAD SHX Text

FLOOR LAYOUT

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text A-101

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AS SHOWN

AutoCAD SHX Text

FE-XXXXX-2J

AutoCAD SHX Text A.H

AutoCAD SHX Text

AutoCAD SHX Text 12/09/2021

AutoCAD SHX Text A.H

AutoCAD SHX Text

AutoCAD SHX Text

BLDG. 730 - FLOOR LAYOUT

AutoCAD SHX Text

SCALE: 1/8" = 1'-0"

AutoCAD SHX Text

1. CONTRACTOR SHALL MAINTAIN AND CLEAN CONSTRUCTION CONTRACTOR SHALL MAINTAIN AND CLEAN CONSTRUCTION AREA AS PER CONTRACT AND SAFETY RECOMMENDATIONS. 2. CONTRACTOR SHALL PROVIDE AND FURNISH TRAFFIC CONTRACTOR SHALL PROVIDE AND FURNISH TRAFFIC CONTROL FOR AREA ADJACENT TO CONSTRUCTION AREA. CONTRACTOR SHALL PROVIDE ALL REQUIRED TRAFFIC CONTROL PLANS. ALL SIGNS, BARRICADES, CHANNELIZATION DEVICES, SIGN FRAMES AND ERECTION OF SUCH DEVICES SHALL CONFORM TO THE REQUIREMENTS OF THE LOCAL TRAFFIC CONTROL AUTHORITY. 3. CONTRACTOR SHALL PROVIDE BUILDING ACCESS TO USER. CONTRACTOR SHALL PROVIDE BUILDING ACCESS TO USER. 4. CONTRACTOR SHALL PROVIDE VEHICULAR ACCESS TO CONTRACTOR SHALL PROVIDE VEHICULAR ACCESS TO PARKING SPACES. 5. ALL WORK SHALL COMPLY WITH THE MANUFACTURER'S ALL WORK SHALL COMPLY WITH THE MANUFACTURER'S SPECIFICATIONS/RECOMMENDATIONS, FEDERAL, STATE, AND LOCAL CODES. 6. CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN A CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN A COMPLETE SET OF CONSTRUCTION DOCUMENTS ON SITE AND INDICATE CHANGES AS THE PROJECT PROGRESSES. 7. NO OBSTRUCTIONS WILL BE PERMITTED WITHIN THREE NO OBSTRUCTIONS WILL BE PERMITTED WITHIN THREE FEET OF FIRE HYDRANTS. 8. ANY DEMOLITION DEBRIS SUSPECTED TO CONTAIN ANY DEMOLITION DEBRIS SUSPECTED TO CONTAIN HAZARDOUS MATERIALS, SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE CONTRACTING OFFICER REPRESENTATIVE PRIOR TO CONTINUING ANY ADDITIONAL WORK. 9. CONTRACTOR SHALL LIFT IN PLACE EXISTING ELECTRICAL CONTRACTOR SHALL LIFT IN PLACE EXISTING ELECTRICAL CONDUIT, GAS LINES, WIRES, ETC., AS REQUIRED. 10. CONTRACTOR IS RESPONSIBLE TO PROTECT ALL EXISTING CONTRACTOR IS RESPONSIBLE TO PROTECT ALL EXISTING EQUIPMENT, MATERIALS AND FINISHES THAT ARE TO REMAIN, AND WITHOUT NECESSARY DAMAGE. ANY DAMAGES SHALL BE REPLACED OR RESTORED WITHOUT ADDITIONAL COST TO THE GOVERNMENT. 11. ALL REMOVED EQUIPMENT SHALL BE INSTALLED AND ALL REMOVED EQUIPMENT SHALL BE INSTALLED AND TESTED IN THE PRESENCE OF A CONTRACTING OFFICER REPRESENTATIVE. 12. CONTRACTOR SHALL NOTIFY CONTRACTING OFFICER'S CONTRACTOR SHALL NOTIFY CONTRACTING OFFICER'S FIELD REPRESENTATIVE IMMEDIATELY OF ANY CONFLICTS DISCOVERED IN THE FIELD TO ALLOW SUFFICIENT TIME TO REVIEW AND RESOLVE THE ISSUE. 13. CONSTRUCTION & DEMOLITION DIVERSION: FORT BLISS CONSTRUCTION & DEMOLITION DIVERSION: FORT BLISS REQUIRES A MINIMUM OF 60% OF CONSTRUCTION AND DEMOLITION MATERIALS AND DEBRIS FROM LANDFILLS. IF THE CONTRACTOR HAS A VALID REASON FOR NOT BEING ABLE TO MEET THIS DIVERSION GOAL, THE CONTRACTOR NEEDS TO PRESENT THEIR REASONING IN WRITING TO DPW-ENVIRONMENTAL DIVISION. 14. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS, CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS, EXACT LOCATIONS AND QUANTITY BEFORE COMMENCING WORK. 15. CONTRACTOR SHALL PROPERLY SECURE WORKING AREA CONTRACTOR SHALL PROPERLY SECURE WORKING AREA TO PROTECT EQUIPMENT, VEHICLES, AND PERSONNEL. 16. THESE PLANS ARE FOR REFERENCE ONLY AND MAY NOT THESE PLANS ARE FOR REFERENCE ONLY AND MAY NOT REFLECT ALL AVAILABLE INFORMATION. THE EXACT LOCATION AND QUANTITY OF EXISTING FEATURES AND EQUIPMENT MAY DEVIATE FROM LOCATIONS AND QUANTITY SHOWN ON DRAWINGS. 17. LOCATIONS OF EQUIPMENT AND DUCTWORK, AS INDICATED LOCATIONS OF EQUIPMENT AND DUCTWORK, AS INDICATED ON THE DRAWING, ARE APPROXIMATE AND SUBJECT TO MINOR ADJUSTMENTS IN THE FIELD. WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE IN THE FIELD.

AutoCAD SHX Text

GENERAL NOTES

AutoCAD SHX Text

AutoCAD SHX Text

BLDG. 730 - GENERAL LAYOUT

SCALE: 1/8" = 1'-0"

S C R

IP

TI

O N

M A R K

D A

TE

D P

W

FO

R T

B

LI

SS

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 103-A

AutoCAD SHX Text 103-B

AutoCAD SHX Text 103-D

AutoCAD SHX Text 103-C

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DESIGNED BY:

AutoCAD SHX Text

SPEC. #

AutoCAD SHX Text W.O. #

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

NUMBER:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

OF

AutoCAD SHX Text

DIRECTORATE OF PUBLIC WORKS FORT BLISS, TEXAS

AutoCAD SHX Text

BUILDING 730 INTERIOR DEMOLITION

AutoCAD SHX Text

CEILING & WALL DEMOLITION

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AD-102

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AS SHOWN

AutoCAD SHX Text

FE-XXXXX-2J

AutoCAD SHX Text A.H

AutoCAD SHX Text

AutoCAD SHX Text 12/09/2021

AutoCAD SHX Text A.H

AutoCAD SHX Text

AutoCAD SHX Text

BLDG. 730 - WALL DEMOLITION

AutoCAD SHX Text

SCALE: 1/8" = 1'-0"

AutoCAD SHX Text

1. CONTRACTOR SHALL MAINTAIN AND CLEAN CONSTRUCTION CONTRACTOR SHALL MAINTAIN AND CLEAN CONSTRUCTION AREA AS PER CONTRACT AND SAFETY RECOMMENDATIONS. 2. CONTRACTOR SHALL PROVIDE AND FURNISH TRAFFIC CONTRACTOR SHALL PROVIDE AND FURNISH TRAFFIC CONTROL FOR AREA ADJACENT TO CONSTRUCTION AREA. CONTRACTOR SHALL PROVIDE ALL REQUIRED TRAFFIC CONTROL PLANS. ALL SIGNS, BARRICADES, CHANNELIZATION DEVICES, SIGN FRAMES AND ERECTION OF SUCH DEVICES SHALL CONFORM TO THE REQUIREMENTS OF THE LOCAL TRAFFIC CONTROL AUTHORITY. 3. CONTRACTOR SHALL PROVIDE BUILDING ACCESS TO USER. CONTRACTOR SHALL PROVIDE BUILDING ACCESS TO USER. 4. CONTRACTOR SHALL PROVIDE VEHICULAR ACCESS TO CONTRACTOR SHALL PROVIDE VEHICULAR ACCESS TO PARKING SPACES. 5. ALL WORK SHALL COMPLY WITH THE MANUFACTURER'S ALL WORK SHALL COMPLY WITH THE MANUFACTURER'S SPECIFICATIONS/RECOMMENDATIONS, FEDERAL, STATE, AND LOCAL CODES. 6. CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN A CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN A COMPLETE SET OF CONSTRUCTION DOCUMENTS ON SITE AND INDICATE CHANGES AS THE PROJECT PROGRESSES. 7. NO OBSTRUCTIONS WILL BE PERMITTED WITHIN THREE NO OBSTRUCTIONS WILL BE PERMITTED WITHIN THREE FEET OF FIRE HYDRANTS. 8. ANY DEMOLITION DEBRIS SUSPECTED TO CONTAIN ANY DEMOLITION DEBRIS SUSPECTED TO CONTAIN HAZARDOUS MATERIALS, SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE CONTRACTING OFFICER REPRESENTATIVE PRIOR TO CONTINUING ANY ADDITIONAL WORK. 9. CONTRACTOR SHALL LIFT IN PLACE EXISTING ELECTRICAL CONTRACTOR SHALL LIFT IN PLACE EXISTING ELECTRICAL CONDUIT, GAS LINES, WIRES, ETC., AS REQUIRED. 10. CONTRACTOR IS RESPONSIBLE TO PROTECT ALL EXISTING CONTRACTOR IS RESPONSIBLE TO PROTECT ALL EXISTING EQUIPMENT, MATERIALS AND FINISHES THAT ARE TO REMAIN, AND WITHOUT NECESSARY DAMAGE. ANY DAMAGES SHALL BE REPLACED OR RESTORED WITHOUT ADDITIONAL COST TO THE GOVERNMENT. 11. ALL REMOVED EQUIPMENT SHALL BE INSTALLED AND ALL REMOVED EQUIPMENT SHALL BE INSTALLED AND TESTED IN THE PRESENCE OF A CONTRACTING OFFICER REPRESENTATIVE. 12. CONTRACTOR SHALL NOTIFY CONTRACTING OFFICER'S CONTRACTOR SHALL NOTIFY CONTRACTING OFFICER'S FIELD REPRESENTATIVE IMMEDIATELY OF ANY CONFLICTS DISCOVERED IN THE FIELD TO ALLOW SUFFICIENT TIME TO REVIEW AND RESOLVE THE ISSUE. 13. CONSTRUCTION & DEMOLITION DIVERSION: FORT BLISS CONSTRUCTION & DEMOLITION DIVERSION: FORT BLISS REQUIRES A MINIMUM OF 60% OF CONSTRUCTION AND DEMOLITION MATERIALS AND DEBRIS FROM LANDFILLS. IF THE CONTRACTOR HAS A VALID REASON FOR NOT BEING ABLE TO MEET THIS DIVERSION GOAL, THE CONTRACTOR NEEDS TO PRESENT THEIR REASONING IN WRITING TO DPW-ENVIRONMENTAL DIVISION. 14. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS, CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS, EXACT LOCATIONS AND QUANTITY BEFORE COMMENCING WORK. 15. CONTRACTOR SHALL PROPERLY SECURE WORKING AREA CONTRACTOR SHALL PROPERLY SECURE WORKING AREA TO PROTECT EQUIPMENT, VEHICLES, AND PERSONNEL. 16. THESE PLANS ARE FOR REFERENCE ONLY AND MAY NOT THESE PLANS ARE FOR REFERENCE ONLY AND MAY NOT REFLECT ALL AVAILABLE INFORMATION. THE EXACT LOCATION AND QUANTITY OF EXISTING FEATURES AND EQUIPMENT MAY DEVIATE FROM LOCATIONS AND QUANTITY SHOWN ON DRAWINGS. 17. LOCATIONS OF EQUIPMENT AND DUCTWORK, AS INDICATED LOCATIONS OF EQUIPMENT AND DUCTWORK, AS INDICATED ON THE DRAWING, ARE APPROXIMATE AND SUBJECT TO MINOR ADJUSTMENTS IN THE FIELD. WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE IN THE FIELD.

AutoCAD SHX Text

GENERAL NOTES

AutoCAD SHX Text

AutoCAD SHX Text

BLDG. 730 - CEILING DEMOLITION

AutoCAD SHX Text

SCALE: 1/8" = 1'-0"

AutoCAD SHX Text GYPSUM BOARD ASSEMBLIES 5/8" TWO-SIDED. 2"x4" WOOD STUDS, 16" O.C.

AutoCAD SHX Text CEILING SUSPENSION SYSTEM, W/T-BAR, 2'x4' GRID, ON 2'x4' WOOD BEAMS, H=12'-6"

AutoCAD SHX Text CEILING, GYPSUM BOARD ON 2'x4' WOOD BEAMS, H=8'-11"

AutoCAD SHX Text DEMOLISH GYPSUM BOARD ASSEMBLIES TO INCLUDE THE WOOD STUDS, POWER OUTLETS BACK TO HOME-RUN, COMM. OUTLETS AND ANY OTHER ARCHITECTURAL, MECHANICAL-ELECTRICAL-PLUMBING SYSTEMS LOCATED ON OR WITHIN THE WALLS.

AutoCAD SHX Text

AutoCAD SHX Text DEMOLISH METAL WALL & METAL CEILING. DEMOLITION DEBRIS OF METAL STRUCTURES SHALL FIT THROUGH EXTERIOR DOORS. WIDENING OF EXISTING EXTERIOR DOORS IS NOT ALLOWED.

AutoCAD SHX Text

AutoCAD SHX Text

KEYED NOTES

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

DEMOLISH CEILING SUSPENSION SYSTEM, TO INCLUDE T-BAR, GRID, AND WOOD BEAMS.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

DEMOLISH CEILING, GYPSUM BOARD TO INCLUDE WOOD BEAMS.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

STRUCTURAL COLUMNS TO REMAIN, TO INCLUDE THE ONES CONCEALED IN PARTITION WALLS.

S C R

IP

TI

O N

M A R K

D A

TE

D P

W

FO

R T

B

LI

SS

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DESIGNED BY:

AutoCAD SHX Text

SPEC. #

AutoCAD SHX Text W.O. #

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

NUMBER:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

OF

AutoCAD SHX Text

DIRECTORATE OF PUBLIC WORKS FORT BLISS, TEXAS

AutoCAD SHX Text

BUILDING 730 INTERIOR DEMOLITION

AutoCAD SHX Text

MECHANICAL DEMOLITION

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

MD-100

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AS SHOWN

AutoCAD SHX Text

FE-XXXXX-2J

AutoCAD SHX Text A.H

AutoCAD SHX Text

AutoCAD SHX Text 12/09/2021

AutoCAD SHX Text A.H

AutoCAD SHX Text

AutoCAD SHX Text

BLDG. 730 - MECHANICAL DEMOLITION

AutoCAD SHX Text

SCALE: 1/8" = 1'-0"

AutoCAD SHX Text

1. CONTRACTOR SHALL MAINTAIN AND CLEAN CONSTRUCTION CONTRACTOR SHALL MAINTAIN AND CLEAN CONSTRUCTION AREA AS PER CONTRACT AND SAFETY RECOMMENDATIONS. 2. CONTRACTOR SHALL PROVIDE AND FURNISH TRAFFIC CONTRACTOR SHALL PROVIDE AND FURNISH TRAFFIC CONTROL FOR AREA ADJACENT TO CONSTRUCTION AREA. CONTRACTOR SHALL PROVIDE ALL REQUIRED TRAFFIC CONTROL PLANS. ALL SIGNS, BARRICADES, CHANNELIZATION DEVICES, SIGN FRAMES AND ERECTION OF SUCH DEVICES SHALL CONFORM TO THE REQUIREMENTS OF THE LOCAL TRAFFIC CONTROL AUTHORITY. 3. CONTRACTOR SHALL PROVIDE BUILDING ACCESS TO USER. CONTRACTOR SHALL PROVIDE BUILDING ACCESS TO USER. 4. CONTRACTOR SHALL PROVIDE VEHICULAR ACCESS TO CONTRACTOR SHALL PROVIDE VEHICULAR ACCESS TO PARKING SPACES. 5. ALL WORK SHALL COMPLY WITH THE MANUFACTURER'S ALL WORK SHALL COMPLY WITH THE MANUFACTURER'S SPECIFICATIONS/RECOMMENDATIONS, FEDERAL, STATE, AND LOCAL CODES. 6. CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN A CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN A COMPLETE SET OF CONSTRUCTION DOCUMENTS ON SITE AND INDICATE CHANGES AS THE PROJECT PROGRESSES. 7. NO OBSTRUCTIONS WILL BE PERMITTED WITHIN THREE NO OBSTRUCTIONS WILL BE PERMITTED WITHIN THREE FEET OF FIRE HYDRANTS. 8. ANY DEMOLITION DEBRIS SUSPECTED TO CONTAIN ANY DEMOLITION DEBRIS SUSPECTED TO CONTAIN HAZARDOUS MATERIALS, SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE CONTRACTING OFFICER REPRESENTATIVE PRIOR TO CONTINUING ANY ADDITIONAL WORK. 9. CONTRACTOR SHALL LIFT IN PLACE EXISTING ELECTRICAL CONTRACTOR SHALL LIFT IN PLACE EXISTING ELECTRICAL CONDUIT, GAS LINES, WIRES, ETC., AS REQUIRED. 10. CONTRACTOR IS RESPONSIBLE TO PROTECT ALL EXISTING CONTRACTOR IS RESPONSIBLE TO PROTECT ALL EXISTING EQUIPMENT, MATERIALS AND FINISHES THAT ARE TO REMAIN, AND WITHOUT NECESSARY DAMAGE. ANY DAMAGES SHALL BE REPLACED OR RESTORED WITHOUT ADDITIONAL COST TO THE GOVERNMENT. 11. ALL REMOVED EQUIPMENT SHALL BE INSTALLED AND ALL REMOVED EQUIPMENT SHALL BE INSTALLED AND TESTED IN THE PRESENCE OF A CONTRACTING OFFICER REPRESENTATIVE. 12. CONTRACTOR SHALL NOTIFY CONTRACTING OFFICER'S CONTRACTOR SHALL NOTIFY CONTRACTING OFFICER'S FIELD REPRESENTATIVE IMMEDIATELY OF ANY CONFLICTS DISCOVERED IN THE FIELD TO ALLOW SUFFICIENT TIME TO REVIEW AND RESOLVE THE ISSUE. 13. CONSTRUCTION & DEMOLITION DIVERSION: FORT BLISS CONSTRUCTION & DEMOLITION DIVERSION: FORT BLISS REQUIRES A MINIMUM OF 60% OF CONSTRUCTION AND DEMOLITION MATERIALS AND DEBRIS FROM LANDFILLS. IF THE CONTRACTOR HAS A VALID REASON FOR NOT BEING ABLE TO MEET THIS DIVERSION GOAL, THE CONTRACTOR NEEDS TO PRESENT THEIR REASONING IN WRITING TO DPW-ENVIRONMENTAL DIVISION. 14. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS, CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS, EXACT LOCATIONS AND QUANTITY BEFORE COMMENCING WORK. 15. CONTRACTOR SHALL PROPERLY SECURE WORKING AREA CONTRACTOR SHALL PROPERLY SECURE WORKING AREA TO PROTECT EQUIPMENT, VEHICLES, AND PERSONNEL. 16. THESE PLANS ARE FOR REFERENCE ONLY AND MAY NOT THESE PLANS ARE FOR REFERENCE ONLY AND MAY NOT REFLECT ALL AVAILABLE INFORMATION. THE EXACT LOCATION AND QUANTITY OF EXISTING FEATURES AND EQUIPMENT MAY DEVIATE FROM LOCATIONS AND QUANTITY SHOWN ON DRAWINGS. 17. LOCATIONS OF EQUIPMENT AND DUCTWORK, AS INDICATED LOCATIONS OF EQUIPMENT AND DUCTWORK, AS INDICATED ON THE DRAWING, ARE APPROXIMATE AND SUBJECT TO MINOR ADJUSTMENTS IN THE FIELD. WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE IN THE FIELD.

AutoCAD SHX Text

GENERAL NOTES

AutoCAD SHX Text

RADIANT HEATER

AutoCAD SHX Text 24" x 24" DIFFUSER

AutoCAD SHX Text 12" x 12" DIFFUSER

AutoCAD SHX Text 12" x 12" RETURN GRILLE

AutoCAD SHX Text DEMOLISH ALL WATER FIXTURES & LAVATORIES TO INCLUDE ALL PLUMBING, CAP OUTSIDE BLDG. SEAL AND CAP WALL.

AutoCAD SHX Text

AutoCAD SHX Text DEMOLISH CENTRAL AIR TO INCLUDE ALL PLUMBING & ELECTRICAL CONNECTIONS TO HOME-RUN.

AutoCAD SHX Text

AutoCAD SHX Text

DEMOLISH ALL DUCTWORK, TO INCLUDE SUPPLY & RETURN GRILLES/REGISTERS.

AutoCAD SHX Text

AutoCAD SHX Text

KEYED NOTES

AutoCAD SHX Text

DEMOLISH CEILING RADIANT HEATERS.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

S C R

IP

TI

O N

M A R K

D A

TE

D P

W

FO

R T

B

LI

SS

1 2

4 4

5 5

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DESIGNED BY:

AutoCAD SHX Text

SPEC. #

AutoCAD SHX Text W.O. #

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

NUMBER:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

OF

AutoCAD SHX Text

DIRECTORATE OF PUBLIC WORKS FORT BLISS, TEXAS

AutoCAD SHX Text

BUILDING 730 INTERIOR DEMOLITION

AutoCAD SHX Text

ELECTRICAL DEMOLITION

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

ED-100

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AS SHOWN

AutoCAD SHX Text

FE-XXXXX-2J

AutoCAD SHX Text A.H

AutoCAD SHX Text

AutoCAD SHX Text 12/09/2021

AutoCAD SHX Text A.H

AutoCAD SHX Text

AutoCAD SHX Text

BLDG. 730 - ELECTRICAL DEMOLITION

AutoCAD SHX Text

SCALE: 1/8" = 1'-0"

AutoCAD SHX Text

GENERAL NOTES

AutoCAD SHX Text

1. LABEL ALL ELECTRICAL EQUIPMENT AS PER NEC. LABEL WITH SELF-ADHESIVE-BACKED LAMINATED PLASTIC LABELS. LABELS SHALL INDICATE NAME OF EQUIPMENT, VOLTAGE, AMPS AND PHASES. LABELS SHALL ALSO INDICATE ORIGIN OF FEEDER CIRCUIT. LETTERING SHALL BE A MINIMUM OF .25 INCHES HIGH. UPDATE OR PROVIDE NEW PANEL SCHEDULES AND SELF-ADHESIVE-BACKED LAMINATED PLASTIC CIRCUIT LABELS FOR EXISTING PANEL WITH CHANGES. LABEL RECEPTACLE COVER PLATES WITH PANEL AND CIRCUIT NUMBER; WHITE LABEL WITH BLACK LETTERS. 2. SEAL AROUND ALL CONDUIT PENETRATIONS IN WALLS, CEILING, AND FLOORS TO RESTORE SURFACE AND FIRE RATING. CONDUIT SHALL BE RUN TO THE MAXIMUM EXTENT POSSIBLE INSIDE OF THE BUILDING. 3. INSTALL ALL CONDUIT USING COMPRESSION TYPE FITTINGS. MINIMUM USE #12 THHN/THWN CU UNLESS OTHERWISE NOTED. WIRE GAGE #10 AND SMALLER SHALL BE SOLID; #8 AND LARGER SHALL BE STRANDED. 4. USE NEMA 3R FOR EXTERIOR INSTALLATIONS AND NEMA 1 FOR INTERIOR INSTALLATIONS UNLESS OTHERWISE NOTED. 5. INSTALLATION SHALL MEET NATIONAL ELECTRICAL CODE . INSTALLATION SHALL MEET NATIONAL ELECTRICAL CODE CLEARANCE REQUIREMENTS. 6. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE CURRENT NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 70, NATIONAL ELECTRICAL CODE (NEC), AND AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) C2, NATIONAL ELECTRICAL SAFETY CODE (NESC).

AutoCAD SHX Text

ELECTRICAL OUTLETS ALONG EXTERIOR WALLS TO REMAIN.

AutoCAD SHX Text

AutoCAD SHX Text

ELECTRICAL PANELS AND DISCONNECTS TO REMAIN.

AutoCAD SHX Text

AutoCAD SHX Text DEMOLISH 2' x 4' RECESSED LIGHT FIXTURE.

AutoCAD SHX Text

AutoCAD SHX Text 1' x 4' SURFACE MOUNTED, WRAPPED AROUND LIGHT FIXTURE, TO BE RE-INSTALLED. SECURE TO ROOF RAFTERS/BEAMS.

AutoCAD SHX Text

AutoCAD SHX Text

KEYED NOTES

AutoCAD SHX Text

AutoCAD SHX Text

DEMOLISH INCANDESCENT LIGHT FIXTURE WITH LED BULB.

AutoCAD SHX Text 1' x 4' POLE MOUNTED LIGHT FIXTURE, TO BE RE-INSTALLED. SECURE TO ROOF RAFTERS/BEAMS.

AutoCAD SHX Text

AutoCAD SHX Text DEMOLISH 1' x 4' POLE MOUNTED LIGHT FIXTURE.

AutoCAD SHX Text

AutoCAD SHX Text DEMOLISH 1' x 4' SURFACE MOUNTED, WRAPPED AROUND LIGHT FIXTURE.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

DEMOLISH POWER POLE, 2-POWER OUTLET, 2-COMM.

AutoCAD SHX Text

COMM/PHONE PATCH PANEL. TO REMAIN.

AutoCAD SHX Text

AutoCAD SHX Text

DEMOLISH COMM/PHONE PATCH PANELS.

AutoCAD SHX Text

4X (TYP.).

AutoCAD SHX Text

4X (TYP.).

AutoCAD SHX Text

3X (TYP.).

AutoCAD SHX Text

7X (TYP.).

AutoCAD SHX Text

3X (TYP.).

AutoCAD SHX Text

7X (TYP.).

AutoCAD SHX Text

3X (TYP.).

AutoCAD SHX Text

7X (TYP.).

AutoCAD SHX Text

AutoCAD SHX Text

8X (TYP.).

AutoCAD SHX Text

3X (TYP.).

AutoCAD SHX Text

4X (TYP.).

AutoCAD SHX Text

4X (TYP.).

AutoCAD SHX Text

3X (TYP.).

AutoCAD SHX Text

3X (TYP.).

AutoCAD SHX Text

2X (TYP.).

AutoCAD SHX Text

4X (TYP.).

AutoCAD SHX Text

8X (TYP.).

AutoCAD SHX Text

4X (TYP.).

AutoCAD SHX Text

6X (TYP.).

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ELECTRICAL NOTES

AutoCAD SHX Text A. DISCONNECT & REMOVE ALL LIGHT FIXTURES, DISCONNECT & REMOVE ALL LIGHT FIXTURES, SWITCHES, JUNCTION BOXES & HARDWARE ASSOCIATED, TO INCLUDE CONDUIT AND CONDUCTORS BACK TO PANEL, UNLESS NOTED OTHERWISE. B. LIGHT FIXTURES INDICATED TO REMAIN SHALL BE LIGHT FIXTURES INDICATED TO REMAIN SHALL BE RECONNECTED WITH NEW TEMPORARY CONNECTIONS USING FLEX CONDUIT ASSEMBLY TO CORRECTLY CONNECTED PANEL. C. DISCONNECT & REMOVE ALL POWER RECEPTACLES, DISCONNECT & REMOVE ALL POWER RECEPTACLES, MECHANICAL EQUIPMENT DISCONNECTS, JUNCTION BOXES & HARDWARE ASSOCIATED, TO INCLUDE CONDUIT & CONDUCTORS BACK TO PANEL, UNLESS NOTED OTHERWISE. D. POWER RECEPTACLES INDICATED TO REMAIN SHALL BE POWER RECEPTACLES INDICATED TO REMAIN SHALL BE RECONNECTED WITH NEW TEMPORARY CONNECTIONS USING FLEX CONDUIT ASSEMBLY TO CORRECTLY CONNECTED PANEL. E. COMMUNICATIONS: PULLOUT COMMUNICATION CABLING COMMUNICATIONS: PULLOUT COMMUNICATION CABLING BACK TO PLYWOOD WALLS AND/OR SERVER RACKS THROUGHOUT THE BUILDING. REMOVE DATA/PHONE DROPS. REMOVE CABLE TRAYS & SERVER RACKS. FIBER SERVICE ENTRANCE TO REMAIN INTACT FOR FUTURE USE.

AutoCAD SHX Text

AutoCAD SHX Text

DEMOLISH ALL EMERGENCY LIGHT HEADS.

AutoCAD SHX Text

AutoCAD SHX Text 2' x 4' RECESSED LIGHT

AutoCAD SHX Text 1' x 4' HANGING LIGHTS

AutoCAD SHX Text 1' x 4' SURFACE MOUNTED LIGHTS, WRAPPED AROUND

AutoCAD SHX Text

ELECTRICAL DISCONNECT

AutoCAD SHX Text

ELECTRICAL PANEL

AutoCAD SHX Text

INCANDESCENT LIGHT FIXTURE WITH LED BULB

AutoCAD SHX Text

POWER POLE, 2-POWER OUTLET, 2-COMM, TYP.

AutoCAD SHX Text

EMERGENCY LIGHT HEADS

AutoCAD SHX Text

WEATHERPROOF DUPLEX RECEPTACLE, 20 AMP, SUBSCRIPT E INDICATES EXISTING.

AutoCAD SHX Text

WP

AutoCAD SHX Text T

AutoCAD SHX Text

TRANSFORMER

AutoCAD SHX Text

HOMERUNS TO PANEL-CIRCUITS INDICATED

CONDUIT WITH WIRE: GROUND, PHASE, SWITCH, AND NEUTRAL RESPECTIVELY

S C R

IP

TI

O N

M A R K

D A

TE

D P

W

FO

R T

B

LI

SS

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DESIGNED BY:

AutoCAD SHX Text

SPEC. #

AutoCAD SHX Text W.O. #

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

NUMBER:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

OF

AutoCAD SHX Text

DIRECTORATE OF PUBLIC WORKS FORT BLISS, TEXAS

AutoCAD SHX Text

BUILDING 730 INTERIOR DEMOLITION

AutoCAD SHX Text

REMAINING LIGHTS & POWER

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text E-100

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AS SHOWN

AutoCAD SHX Text

FE-XXXXX-2J

AutoCAD SHX Text A.H

AutoCAD SHX Text

AutoCAD SHX Text 12/09/2021

AutoCAD SHX Text A.H

AutoCAD SHX Text

AutoCAD SHX Text

BLDG. 730 - LIGHTS & POWER TO REMAIN

AutoCAD SHX Text

SCALE: 1/8" = 1'-0"

AutoCAD SHX Text

GENERAL NOTES

AutoCAD SHX Text

1. LABEL ALL ELECTRICAL EQUIPMENT AS PER NEC. LABEL WITH SELF-ADHESIVE-BACKED LAMINATED PLASTIC LABELS. LABELS SHALL INDICATE NAME OF EQUIPMENT, VOLTAGE, AMPS AND PHASES. LABELS SHALL ALSO INDICATE ORIGIN OF FEEDER CIRCUIT. LETTERING SHALL BE A MINIMUM OF .25 INCHES HIGH. UPDATE OR PROVIDE NEW PANEL SCHEDULES AND SELF-ADHESIVE-BACKED LAMINATED PLASTIC CIRCUIT LABELS FOR EXISTING PANEL WITH CHANGES. LABEL RECEPTACLE COVER PLATES WITH PANEL AND CIRCUIT NUMBER; WHITE LABEL WITH BLACK LETTERS. 2. SEAL AROUND ALL CONDUIT PENETRATIONS IN WALLS, CEILING, AND FLOORS TO RESTORE SURFACE AND FIRE RATING. CONDUIT SHALL BE RUN TO THE MAXIMUM EXTENT POSSIBLE INSIDE OF THE BUILDING. 3. INSTALL ALL CONDUIT USING COMPRESSION TYPE FITTINGS. MINIMUM USE #12 THHN/THWN CU UNLESS OTHERWISE NOTED. WIRE GAGE #10 AND SMALLER SHALL BE SOLID; #8 AND LARGER SHALL BE STRANDED. 4. USE NEMA 3R FOR EXTERIOR INSTALLATIONS AND NEMA 1 FOR INTERIOR INSTALLATIONS UNLESS OTHERWISE NOTED. 5. INSTALLATION SHALL MEET NATIONAL ELECTRICAL CODE . INSTALLATION SHALL MEET NATIONAL ELECTRICAL CODE CLEARANCE REQUIREMENTS. 6. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE CURRENT NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 70, NATIONAL ELECTRICAL CODE (NEC), AND AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) C2, NATIONAL ELECTRICAL SAFETY CODE (NESC).

AutoCAD SHX Text

ELECTRICAL OUTLETS ALONG EXTERIOR WALLS TO RECONNECT BACK TO PANEL.

AutoCAD SHX Text

AutoCAD SHX Text

ELECTRICAL PANELS AND DISCONNECTS TO REMAIN.

AutoCAD SHX Text

AutoCAD SHX Text 1' x 4' SURFACE MOUNTED, WRAPPED AROUND LIGHT FIXTURE SECURE TO ROOF RAFTERS/BEAMS.

AutoCAD SHX Text

AutoCAD SHX Text

KEYED NOTES

AutoCAD SHX Text 1' x 4' LIGHT FIXTURE SECURE TO ROOF RAFTERS/BEAMS.

AutoCAD SHX Text

AutoCAD SHX Text 2' x 4' RECESSED LIGHT

AutoCAD SHX Text 1' x 4' HANGING LIGHTS

AutoCAD SHX Text 1' x 4' SURFACE MOUNTED LIGHTS, WRAPPED AROUND

AutoCAD SHX Text

ELECTRICAL DISCONNECT

AutoCAD SHX Text

ELECTRICAL PANEL

AutoCAD SHX Text

INCANDESCENT LIGHT FIXTURE WITH LED BULB

AutoCAD SHX Text

POWER POLE, 2-POWER OUTLET, 2-COMM, TYP.

AutoCAD SHX Text

EMERGENCY LIGHT HEADS

AutoCAD SHX Text

ELECTRICAL NOTES

AutoCAD SHX Text A. LIGHT FIXTURES INDICATED TO REMAIN SHALL BE LIGHT FIXTURES INDICATED TO REMAIN SHALL BE RECONNECTED WITH NEW TEMPORARY CONNECTIONS USING FLEX CONDUIT ASSEMBLY TO CORRECTLY CONNECTED PANEL. B. POWER RECEPTACLES INDICATED TO REMAIN SHALL BE POWER RECEPTACLES INDICATED TO REMAIN SHALL BE RECONNECTED WITH NEW TEMPORARY CONNECTIONS USING FLEX CONDUIT ASSEMBLY TO CORRECTLY CONNECTED PANEL.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

4X (TYP.).

AutoCAD SHX Text

WEATHERPROOF DUPLEX RECEPTACLE, 20 AMP, SUBSCRIPT E INDICATES EXISTING.

AutoCAD SHX Text

WP

AutoCAD SHX Text T

AutoCAD SHX Text

TRANSFORMER

AutoCAD SHX Text

HOMERUNS TO PANEL-CIRCUITS INDICATED

AutoCAD SHX Text

CONDUIT WITH WIRE: GROUND, PHASE, SWITCH, AND NEUTRAL RESPECTIVELY

AutoCAD SHX Text

4X (TYP.).

AutoCAD SHX Text SECURE THE LIGHTS BY RE-USING PREVIOUS ATTACHMENT METHODS OR BY WRAPPING AROUND ROOF RAFTERS/BEAMS. NEW PENETRATIONS TO MECHANICALLY FASTEN THE CEILING LIGHTS IS NOT ALLOWED.

AutoCAD SHX Text

AutoCAD SHX Text NEW PENETRATIONS TO SECURE REMAINING ELECTRICAL OUTLETS TO EXTERIOR WALL ARE NOT ALLOWED. IF REMOVAL OR RELOCATION OF THE OUTLET IS NECESSARY, EXISTING PENETRATIONS ARE TO BE RE-USED.

AutoCAD SHX Text

AutoCAD SHX Text STRUCTURAL COLUMNS ARE SHOWN AS REFERENCE ONLY. ALL STRUCTURAL COLUMNS TO REMAIN.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

Sheets and Views
DWG_FINAL_Bldg 730_Interior Demolition-A-100
DWG_FINAL_Bldg 730_Interior Demolition-A-101
DWG_FINAL_Bldg 730_Interior Demolition-AD-102
DWG_FINAL_Bldg 730_Interior Demolition-MD-100
DWG_FINAL_Bldg 730_Interior Demolition-ED-100
DWG_FINAL_Bldg 730_Interior Demolition-E-100

File details come from the government source that posted it. Updated .