BRIDGE INSPECTION REPORT
MONOCACY BRIDGE
PARK ACCESS ROAD OVER STREAM
MONOCACY NATIONAL BATTLEFIELD
LW
STRUCTURE NO. 3130-001P
INSPECTION TYPE: ROUTINE
INSPECTION DATE: 10/22/13
Report prepared by: SU
Federal Highway Administration Federal Lands Bridge Office Bridge Inspection and Management Program 21400 Ridgetop Circle Sterling, Virginia 20166 http://www.efl.fhwa.dot.gov/FLHBO/BIP
STRUCTURE SUMMARY STRUCTURE NO. 3130-001P
MONOCACY BRIDGE INSPECTION DATE: 10/22/13
BRIDGE IDENTIFICATION AND DESCRIPTION
MAIN SPAN MATERIAL: ....... WOOD or TIMBER NO. OF MAIN SPANS:
MAIN SPAN TYPE: ............... SLAB NO. OF APPR. SPANS:
# OF BEAMS, MAIN SPAN: .. 9 STRUCT. TOTAL LENGTH: .. 21.0 FT (6.4 M)
DECK TYPE: ......................... WOOD OR TIMBER MAX. SPAN LENGTH: .......... 19.0 FT (5.8 M) WEARING SURFACE: .......... NONE DECK WIDTH: ...................... 13.5 FT (4.1 M) ABUT. FOUNDATIONS: ........ SPREAD FTG ON BEARING MAT'L CURB TO CURB WIDTH: ..... 12.2 FT (3.7 M)
PIER FOUNDATION(S): ........ N/A YEAR BUILT:
ABUTMENT / PIER MAT'L: ... CONCRETE YEAR RECONSTRUCTED: .. N/A
PROJ./PLAN REF. NO: ......... MONOCACY BR. / 8540.3 SKEW ANGLE: ..................... 0 °
NPS ROAD CLASS: .............. 1 - PRINCIPAL PARK ROAD FRACTURE CRITICAL: ........ NO STRUCTURE HISTORY: ...... 2001 - APPROACHES REPAVED. 2002-DETERIORATED AREAS OF DECK REPAIRED W /
EPOXY PATCHES; DECK JOINTS CLEANED/RESEALED. 2006-GABION BASKETS REMOVED,
LOCATION
MONOCACY NATIONAL BATTLEFIELD MILE POINT: ..................... 0.00 (KM PT 0.00) STATE: ................................. MARYLAND LOCATION: 0.15 MILES FROM MD ROUTE 355
FACILITY CARRIED: ............ PARK ACCESS ROAD
FEATURE INTERSECTED: .. STREAM
STRUCTURE EVALUATION SUMMARY
This structure is a glue-laminated timber deck panel bridge. The structure is currently in fair condition overall, but exhibits some problems that require attention. These include weathering and deterioration of the timber deck; a large split in the deck at the northeast corner under the curb, causing the railing to lean outward; deterioration of the deck joint sealer at both abutments; and moderate scour along the east abutment. Corrective measures should be taken as outlined in this report to help prevent the possible development of more serious or costly problems in the future.
It should be noted that the bridge meets state legal load standards and does not require posting of load limit signs.
However, the bridge may be posted at the discretion of the Park to control the type of vehicle that accesses the facility. Options for such signing have previously been furnished to the Park.
INSPECTION TEAM: O. AJIDE, G. GOODLIN
CONDITION ASSESSMENT:
OLUWASEUN AJIDE, FIELD TEAM LEADER 703-948-1419
REPORT REVIEW :
MARCUS MILLER, P.E., SENIOR INSPECTION ENGINEER 703-404-6252
REPORT APPROVAL: DATE: 2/14/14
JORGOMAI CEESAY, PH.D., P.E., BIP SUPERVISORY ENGINEER 703-404-6244
RECOMMENDATIONS AND ESTIMATED COSTS STRUCTURE NO. 3130-001P
A (Critical) - Structure is closed, in imminent danger of collapse, or presents a critical safety hazard.
B (Major) - Structure is seriously deficient or presents a safety hazard, but can remain in service at reduced loads or with frequent inspections.
C (Moderate) - Structure is deficient, functionally obsolete, or requires substantial repairs to prevent a serious deficiency or unsafe condition.
D (Minor) - Structure is generally in good condition. Preventative maintenance may be required.
E (Special) - Structure is under construction or reconstruction.
C226 PRIORITY OF IMPROVEMENT
ITEM
NO.
MAINTENANCE RECOMMENDATIONS
(GENERALLY NOT FLHP ELIGIBLE)
QTY. UNIT COST
UNIT
ESTIMATE
COST
PRELIM.
58.2 CLEAN AND RESEAL DECK JOINTS AT BOTH ABUTMENTS. BRING JOINT SEAL UP
TO GRADE.
58.1, 59.3 CLEAN DECK AND APPLY APPROVED GLULAM TIMBER SEALER TO SURFACE.
58.1, 59.3 SECURE NORTH EDGE OF DECK AT NORTHEAST CORNER OF BRIDGE. 1
222.4 SEAL CRACKS IN PAVEMENT AT WEST APPROACH.
PRELIM. MAINTENANCE TOTAL :
ITEM
NO.
REHABILITATION/RECONSTRUCTION
(TYPICALLY NEEDED WITHIN 5 YEARS) QTY. UNIT UNIT
COST ESTIMATES
PRELIM. COST
REHAB. RECONSTR.
60.5,9 INSTALL ENGINEERED RIPRAP ALONG FACE OF EAST ABUTMENT. 5 CY
PRELIM. REHABILITATION/RECONSTRUCTION TOTAL : $0
COST ESTIMATE SUMMARY
PRELIM. MAINTENANCE TOTAL:
PRELIM. REHABILITATION TOTAL:
PRELIMINARY ESTIMATE TOTAL* :
(*Includes typical contract costs for mobilization, traffic control, and design/construction engineering; but does not include detour bridges, work beyond the bridge limits, or work not listed above. Estimates are approximate and are for preliminary planning purposes only; they should not be used as a complete or final engineers estimate.)
REMARKS: Cost estimates are based on historical data, including costs for similar projects when available.
FIELD INSPECTION REPORT STRUCTURE NO. 3130-001P
CONDITION RATING CODES FOR ITEMS 58 - 62, 222, 223
N NOT APPLICABLE
9 EXCELLENT CONDITION
8 VERY GOOD CONDITION - no problems noted.
7 GOOD CONDITION - some minor problems.
6 SATISFACTORY CONDITION - structural elements show some minor deterioration.
5 FAIR CONDITION - all primary structural elements are sound but may have minor section loss, cracking, spalling, or scour.
4 POOR CONDITION - advanced section loss, deterioration, spalling, or scour.
3 SERIOUS CONDITION - loss of section, deterioration, spalling, or scour have seriously affected primary structural components. Local failures are possible.
Fatigue cracks in steel or shear cracks in concrete may be present.
2 CRITICAL CONDITION - advanced deterioration of primary structural elements. Fatigue cracks in steel or shear cracks in concrete may be present or scour may have removed substructure support. Unless closely monitored it may be necessary to close the structure until corrective action can be taken.
1 “IMMINENT” FAILURE CONDITION - major deterioration or section loss present in critical structural components or obvious vertical or horizontal movement affecting structure stability. Structure is closed to traffic but corrective action may return structure to light service.
0 FAILED CONDITION - out of service; beyond corrective action.
CONDITION RATING CODE EQUIVALENTS FOR SUB-ELEMENTS
G = GOOD (CODES 7 - 9) F = FAIR (CODES 5 - 6) P = POOR (CODES 0 - 4)
58. DECK 5
1. DECK SLAB F
2. EXPANSION JOINTS P
3. WEARING SURFACE N
4. RIDEABILITY G
5. CURBS, SIDEWALKS, AND MEDIAN G
6. PARAPETS AND/OR RAILINGS F
7. DRAINS AND DRAINAGE G
8. UTILITIES N
9. DEFLECTION AND/OR VIBRATION G
10. OTHER N
59. SUPERSTRUCTURE 5
1. BEARING DEVICES
2. GIRDERS OR BEAMS
3. ARCH(ES) OR SLAB(S)
4. FLOOR BEAMS AND STRINGERS
5. TRUSSES
6. DIAPHRAGMS AND BRACING
7. PAINT
8. FASCIA(E)
9. DEFLECTION AND/OR VIBRATION
10. ALIGNMENT
11. OTHER
60. SUBSTRUCTURE
ABUTMENTS
1. BREASTWALLS OR COLUMNS
2. PILE BENTS
3. CAPS AND/OR BEARING SEATS
4. BACKWALLS AND/OR BULKHEADS
5. FOUNDATIONS
6. WINGWALLS
7. WEEP HOLES
8. EXPANSION JOINTS
9. EROSION AND/OR SCOUR
10. SETTLEMENT OR DEFLECTION
11. SLOPE PROTECTION
12. OTHER
PIER(S)
13. WALLS AND/OR COLUMNS
14. PILE BENTS
15. CAPS AND/OR BEARING SEATS
16. FOUNDATIONS
17. EROSION AND/OR SCOUR
18. SETTLEMENT OR DEFLECTION
19. OTHER
N N F N N F N N G G N
G N G G G G N N F G G N
N N N N N N N
58.1, 59.3
58.2
58.5
58.6
59.6
60.4
60.5,9,11
ITEM REFERENCE AND REMARKS
WIDESPREAD WEATHERING AND MODERATE CHECKING
THROUGHOUT PREFABRICATED TIMBER DECK PANELS.
MODERATE DETERIORATION OF TOP SURFACE AT ENDS OF
PANELS. BOLT HOLES IN DECK SURFACE LOCATED NEAR BOTH
ABUTMENTS ARE FULL OF DEBRIS AND VEGETATION GROWTH.
LARGE SPLIT (1/2" W X 11' L) IN TIMBER DECK AT NORTHEAST
CORNER UNDER CURB, CAUSING RAILING TO LEAN OUTWARD (SEE
58.6).
MINOR CHIPPING OF BOTTOM EDGE OF EXTERIOR PANELS, LIKELY
DUE TO COLLISION FROM FLOOD DEBRIS. SIGNS OF INCIPIENT
DECAY ON DECK UNDERSIDE AT BEARING AREAS.
MODERATE DETERIORATION OF DECK JOINT SEALER WITH DEBRIS
AND VEGETATION GROWTH IN JOINT.
CHECKING AND MINOR DECAY OF TIMBER CURBS; FULL LENGTH
CHECK IN SOUTH CURB; MINOR DECAY ALONG UNDERSIDE OF
CURBS, BOTH EDGES OF DECK.
MINOR COLLISION DAMAGE TO CURBS.
DEBRIS AND VEGETATION GROWTH ALONG AND UNDER CURBS.
MINOR DETERIORATION OF RAILING TIMBER. MINOR COLLISION
DAMAGE TO RAILING. MODERATE CHECKING OF RAIL POSTS.
EAST RAILING LEANS OUTWARD AT NORTH END.
DECK PANELS ARE HELD TOGETHER BY TWO LATERAL TIES ON
UNDERSIDE OF DECK; BOTH LATERAL TIES ARE SPLIT AT
DOWNSTREAM END, AND CHECKED AT UPSTREAM END.
MODERATE SCALING OF TOP SURFACE OF BOTH BACKWALLS HAS
EXPOSED STONE AGGREGATE IN CONCRETE.
MODERATE SCOUR ALONG EAST ABUTMENT BREASTWALL;
FOOTING NOT EXPOSED AT TIME OF INSPECTION.
RIPRAP IN PLACE ALONG CORNERS OF EAST ABUTMENT. RIPRAP
AT WEST ABUTMENT SLOPE HAS BEEN PARTLY WASHED AWAY;
SOME RIPRAP REMAINS IN PLACE UNDER WEST END OF SPAN.
INSPECTION DATE: 10/22/13
STRUCTURE NO. 3130-001P FIELD INSPECTION REPORT
MONOCACY BRIDGE
ITEM REFERENCE AND REMARKS
AVERAGE CLEAR OPENING 8.
7. NORMAL VELOCITY
ADEQUACY OF OPENING 6.
5. OTHER
4. WATERWAY OBSTRUCTIONS
CHANNEL PROTECTION3.
EROSION AND/OR SCOUR2.
ALIGNMENT1.
61. CHANNEL 6
F G G G N
LOW
SUFF
3 FT.
9. STREAM BED COMPOSITION :
SILT, SAND
222. APPROACHES 6
OTHER 9.
ALIGNMENT 8.
SIGNS7.
SETTLEMENT 6.
EROSION5.
SURFACING4.
APPROACH GUARDRAIL 3.
2. RELIEF JOINTS
APPROACH SLABS1. N
N N F G G G G N
223. RETAINING WALL N
OTHER 6.
SETTLEMENT OR DEFLECTION5.
EROSION AND/OR SCOUR4.
FOUNDATION3.
WEEP HOLES2.
1. WALL
36. TRAFFIC AND SAFETY FEATURES
APPROACH GUARDRAIL ENDSD.
APPROACH GUARDRAILSC.
TRANSITIONSB.
BRIDGE RAILINGSA. 1
N N N
61.1 STREAM FLOWS AGAINST EAST ABUTMENT, CAUSING SCOUR
ALONG BREASTWALL AND NORTHEAST WINGWALL (SEE 60.5,9).
SMALL STREAM JOINS CHANNEL APPROXIMATELY 25'
DOWNSTREAM FROM BRIDGE.
61.2,3,4 EXTENSIVE RIPRAP BANK PROTECTION HAS BEEN PLACED ALONG
BOTH BANKS AT UPSTREAM SIDE OF STRUCTURE; SEVERAL
STONES HAVE DISLODGED AND ROLLED INTO CHANNEL.
222.4,6 RIPRAP AND TOPSOIL HAVE BEEN INSTALLED TO REPAIR
PREVIOUSLY REPORTED EROSION OF APPROACH EMBANKMENT
AT NORTHEAST CORNER OF BRIDGE.
MINOR TO MODERATE RANDOM CRACKING OF PAVEMENT AT WEST
APPROACH.
222.7 "SPEED LIMIT 15", AND "TRASH FREE PARK" SIGNS AT WEST
APPROACH, SOUTH SIDE. TYPE 3 (B/Y) OBJECT MARKER PANELS
ON WOOD POSTS AT CORNERS OF BRIDGE.
TRAFFIC SAFETY RATING CODES
N
Does not meet standards or a safety feature is required and none is provided.
Meets currently acceptable standards.
Not applicable or a safety feature is not required.
STRUCTURE LOAD RATING STRUCTURE NO. 3130-001P
TRUCK TYPE
INVENTORY RATING (NORMAL TRAFFIC) OPERATING RATING (MAXIMUM LOAD)
TONS METRIC TONS TONS METRIC TONS
H 20 18 27 24
HS 36 33 48 43
TYPE 3 29 27 39 35
TYPE 3S2 46 42 62 56
TYPE 3-3 57 52 76 69
DESIGN LOADING: HS20 (MS18)
X CAPACITY MEETS OR EXCEEDS DESIGN LOAD
CAPACITY IS LESS THAN DESIGN LOAD
ORIGINAL LOAD RATING CALCULATION APPLICABLE
ORIGINAL LOAD RATING CALCULATION REVISED
DATE OF LOAD RATING CALCULATION:
LOAD RATING CONTROLLED BY:
REMARKS: RATING IS BASED ON DESIGN LOAD OF STRUCTURE.
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 3130-001P
STRUCTURE IDENTIFICATION
(201) PARK: MONOCACY NATIONAL BATTLEFIELD (1) STATE: ....................................... 243 - MARYLAND (MD)
(202) STRUCTURE NAME: .......... MONOCACY BRIDGE (2) STATE HWY. AGENCY DIST:
(203) STRUCTURE KIND: ............1 - BRIDGE (3) COUNTY CODE: ........................ 021 - FREDERICK
(204) STRUCTURE NUMBER: ..... 3130-001P (4) CITY/PLACE CODE:
(205) NPS REGION: .................... 2 - NATIONAL CAPITAL (5) INVENTORY ROUTE:
(206) ROUTE CODE NUMBER: ... 0 (6) FEATURES INTERSECTED:....... STREAM
(207) ROAD SECTION NO: ..........001P (7) FACILITY CARRIED: .................. PARK ACCESS ROAD
(208) NPS ROAD CLASS: ............ 1 - PRINCIPAL PARK ROAD (8) STATE STRUCTURE NO: .......... 3130001P0000000
(209) WITHIN NPS BNDRY?: .......YES (9) LOCATION: ................................ 0.15 MILES FROM MD ROUTE
(210) OPERATING UNIT: .............PARK (10) INV. RTE. - MIN. VERT. CLR: .. 99.99 FT (99.99 M)
(211) PROJECT NO(S): ................MONOCACY BR. (11) MILE POINT: ............................. 0.00 (KM PT 0.00)
(212) DRAWING NUMBERS: ....... 8540.3 (27) YEAR BUILT:
(21) MAINTAINED BY: ................. 66 - NATIONAL PARK SERVICE (106) YEAR RECONSTRUCTED: .... N/A
(22) OWNER: ............................... 66 - NATIONAL PARK SERVICE (20) TOLL: ........................................ 3 - FREE ROAD
(37) HISTORICAL DESIGNATION: .. 5 - NOT ELIGIBLE
STRUCTURE DESCRIPTION, FOUNDATION, AND DECK TYPE
(43A) MAIN STR. MATERIAL: ..
(43B) MAIN STR. TYPE:
(45) NO. OF MAIN SPANS:
(48) MAX. SPAN LENGTH:
(49) STRUCTURE LENGTH:
(216A) ABUTMENT #1 FDN:
(216B) ABUTMENT #2 FDN:
(217A) PREDOM. PIER FDN.: ..
(217B) SECOND. PIER FDN: ...
(107) DECK TYPE:
7 - WOOD or TIMBER
01 - SLAB
19.0 FT (5.8 M)
21.0 FT (6.4 M)
2 - SPREAD FTG ON BEARING MAT'L
2 - SPREAD FTG ON BEARING MAT'L
6 - N/A
6 - N/A
8 - WOOD OR TIMBER
(44A) APPR. STR. MATERIAL: ........ 0 - OTHER
(44B) APPR. STR. TYPE: ................ 00 - OTHER
(46) NO. OF APPROACH SPANS: .. 0
(108) WEAR SURFACE/PROTECT SYSTEM:
A) TYPE WEARING SURFACE: .. 0 - NONE
B) TYPE MEMBRANE: ................. 0 - NONE
C) TYPE PROTECTION: .............. 0 - NONE
(218) IS SALT USED?: ..................... NO
LOAD RATING AND POSTING
(31) DESIGN LOAD: ................. 5 - HS20 (MS18) (41) LOAD RESTRICTION: ......... A - OPEN, NO RESTRICTION
(66) INVENTORY RATING: ...... 36.0 TONS (32.7 METRIC TONS) (70) BRIDGE POSTING: .............. 5 - NO POSTING REQUIRED
(64) OPERATING RATING: ...... 47.9 TONS (43.4 METRIC TONS)
INSPECTION DATES
(90) INSPECTION DATE: 10/13 (91) FREQ. OF INSP: 24 MONTHS (92 / 93) CRITICAL FEATURE INSPECTION (CFI):
(219) ADD. STUDIES NEEDED: N - 0 - NONE (A) FRACTURE CRITICAL: ... NO
INSP. EVERY: MONTHS - LAST INSP. : (220) SPECIAL STUDY TYPE: 0 - NONE
(B) UNDERWATER: .............. NO
(221) SPECIAL STUDY DATE: INSP. EVERY: MONTHS - LAST INSP. :
(C) SPECIAL INSPECTION: .. NO
INSP. EVERY: MONTHS - LAST INSP. :
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 3130-001P
GEOMETRY, TRAFFIC, AND NAVIGATIONAL DATA
(16) LATITUDE: ............................. 39°22'00.40" (51) CURB TO CURB WIDTH: ........... 12.2 FT (3.7 M)
(17) LONGITUDE: ......................... 77°23'16.00" (52) DECK WIDTH: ............................ 13.5 FT (4.1 M)
(19) DETOUR LENGTH: ............... 0 MI (0 KM) (32) APPR. ROADWAY WIDTH: ........ 20.0 FT (6.1 M)
(28A) LANES ON STRUCT: .......... 01 (213) APPR. PAVEMENT WIDTH: ..... 20.0 FT (6.1 M)
(28B) LANES UNDER STRUCT: ... 00 LEFT SHOULDER: .................. 0.0 FT (0.0 M)
(42A) SERVICE ON: ..................... 1 - HIGHWAY RIGHT SHOULDER: ................ 0.0 FT (0.0 M)
(42B) SERVICE UNDER: .............. 5 - WATERWAY (33) BRIDGE MEDIAN: ....................... 0 - NO MEDIAN
(29) AVG. DAILY TRAFFIC: .......... 60 (34) SKEW ANGLE: ............................ 0 °
(30) YEAR OF ADT: ...................... 2007 (35) DECK FLARE?: ........................... NO
(114) FUTURE ADT: ..................... 66 (47) TOTAL HORIZ. CLEARANCE: .... 12.0 FT (3.7 M)
(115) YEAR OF FUTURE ADT: ..... 2027 (50) SIDEWALKS:
(101) PARALLEL STRUCTURE: ... N - NONE LEFT : ...................................... 0.0 FT (0.0 M)
(38) NAVIGATION CONTROL?: ... 0 RIGHT : ................................... 0.0 FT (0.0 M)
(39) VERTICAL CLEARANCE: ...... 0.0 FT (0.0 M) (214) BRIDGE RAIL TYPE:
(40) HORIZ. CLEARANCE: ........... 0.0 FT (0.0 M) RAIL CONFIGURATION: ......... 1 - FULL HEIGHT (NO PARAPE
(111) ABUT. OR PIER PROT: ....... 1 - NAV PROTECTION NOT REQUIRED MATERIAL: .............................. 7 - TIMBER
DESIGN TYPE: ........................ 1 - CONTINUOUS RAIL LATERAL UNDERCLEARANCE:
(55) RIGHT: ....................... 0.0 FT (0.0 M) (215) BRIDGE RAIL HEIGHT: ............ 3.50 FT (1.07 M)
(56) LEFT: ......................... 0.0 FT (0.0 M) (53) MIN. VRT. CLEAR. OVER DECK: 99.99 FT (99.99 M)
(54) MIN. VRT. UNDERCLEARANCE: 0.00 FT (0.00 M)
CONDITION AND APPRAISAL DATA, PROPOSED IMPROVEMENTS, AND COST
(58) DECK:
(59) SUPERSTRUCTURE:
(60) SUBSTRUCTURE:
(61) CHANNEL:
(62) CULVERT: ........................... N
(222) APPROACHES:
(223) RETAINING WALL: ...........N
(36) TRAFFIC SAFETY FEAT: ... 1NNN
(75A) TYPE OF WORK: .............. 35 - GENERAL REHAB
(75B) WORK DONE BY: ............. 2 - OWNER
(76) IMPROVEMENT LENGTH: ..
(67) STRUCTURAL EVALUATION:
(68) DECK GEOMETRY:
(69) UNDERCLEARANCES:
(71) WATERWAY ADEQUACY:
(72) APPROACH ALIGNMENT:
(113) SCOUR CRITICAL:
(225) PURPOSE OF IMPROVEMENT:
(226) PRIORITY OF IMPROVEMENT:
(227) MAINTENANCE COST:
(228) REHAB./RECONSTR. COST: ...
(229) CONSTRUCTION COST:
N
4 - Stable; action required to pro
2 - REHAB/RECONSTRUCTION
C - MODERATE
ADDITIONAL INFORMATION
(230) STRUCTURE HISTORY:
2001 - APPROACHES REPAVED. 2002-DETERIORATED AREAS OF DECK REPAIRED W/ EPOXY PATCHES; DECK JOINTS
CLEANED/RESEALED. 2006-GABION BASKETS REMOVED, RIPRAP PLACED.
(231) ADDITIONAL CONSIDERATIONS:
(330) ADDITIONAL CONFIG. INFO.:
APPENDIX STRUCTURE NO. 3130-001P
PHOTOGRAPHS STRUCTURE NO. 3130-001P
PHOTO #1 - LOOKING EAST TOWARD VISITOR CENTER
FLOW
PHOTO #2 - NORTH (DOWNSTREAM) SIDE
PHOTO #3 - GENERAL TOPSIDE VIEW LOOKING WEST
PHOTO #4 - TYPICAL WEATHERING AND CHECKING OF TOP SURFACE
OF TIMBER DECK PANELS
PHOTO #5 - TYPICAL DETERIORATION OF
DECK JOINT SEALER, EAST JOINT SHOWN;
NOTE DEBRIS AND VEGETATION GROWTH
PHOTO #6 - CRACKING OF WEST APPROACH
PAVEMENT
PHOTO #7 - FULL LENGTH CHECK IN SOUTH TIMBER CURB
PHOTO #8 - TYPICAL COLLISION DAMAGE TO CURB AND RAILING,
SOUTHWEST CORNER SHOWN
PHOTO #9 - NORTH END OF EAST RAILING; NOTE OUTWARD LEAN OF
RAILING
PHOTO #10 - GENERAL UNDERSIDE VIEW OF STRUCTURE LOOKING
WEST
PHOTO #11 - SPLIT IN DOWNSTREAM END OF EAST LATERAL TIE ON
UNDERSIDE OF DECK
PHOTO #12 - GENERAL VIEW OF EAST ABUTMENT; NOTE SCOUR
ALONG FACE OF ABUTMENT
PHOTO #13 - CLOSE UP SCOUR AT NORTH CORNER OF EAST
ABUTMENT
PHOTO #14 - GENERAL VIEW OF RIPRAP AT NORTHEAST CORNER;
NOTE DISLODGED STONES AND EXPOSED FILTER FABRIC
PHOTO #15 - RIPRAP BANK PROTECTION ALONG EAST BANK AT
UPSTREAM SIDE OF STRUCTURE; NOTE SEVERAL DISLODGED
STONES IN CHANNEL
PHOTO #16 - PARTIAL WASHOUT OF RIPRAP AT WEST ABUTMENT
PHOTO #17 - RIPRAP AND TOPSOIL INSTALLED TO STABILIZE
EMBANKMENT EROSION AT NORTHEAST CORNER OF BRIDGE
PHOTO #18 - LOOKING UPSTREAM FROM BRIDGE
PHOTO #19 - LOOKING DOWNSTREAM FROM BRIDGE