BRIDGE INSPECTION REPORT

SHORELINE ROAD BRIDGE

SHORELINE ROAD OVER OLD CANAL LAGOON

HARPERS FERRY NATIONAL HISTORICAL PARK

LW

STRUCTURE NO. 3850-002P

INSPECTION TYPE: ROUTINE

INSPECTION DATE: 10/24/13

Report prepared by: SD

Federal Highway Administration Federal Lands Bridge Office Bridge Inspection and Management Program 21400 Ridgetop Circle Sterling, Virginia 20166 http://www.efl.fhwa.dot.gov/FLHBO/BIP

STRUCTURE SUMMARY STRUCTURE NO. 3850-002P

SHORELINE ROAD BRIDGE INSPECTION DATE: 10/24/13

BRIDGE IDENTIFICATION AND DESCRIPTION

MAIN SPAN MATERIAL: ....... PRESTRESSED CONCRETE NO. OF MAIN SPANS:

MAIN SPAN TYPE: ............... STRINGER/MULTI-BEAM or GIRDER NO. OF APPR. SPANS:

# OF BEAMS, MAIN SPAN: .. 4 STRUCT. TOTAL LENGTH: ..

DECK TYPE: ......................... CONCRETE CAST-IN-PLACE MAX. SPAN LENGTH:

WEARING SURFACE: .......... NONE DECK WIDTH:

ABUT. FOUNDATIONS: ........ SPREAD FTG ON BEARING MAT'L CURB TO CURB WIDTH:

PIER FOUNDATION(S): ........ SPREAD FTG ON BEARING MAT'L YEAR BUILT:

ABUTMENT / PIER MAT'L: ... CONCRETE YEAR RECONSTRUCTED: ..

PROJ./PLAN REF. NO: ......... 14-1(1) / 00000 SKEW ANGLE:

NPS ROAD CLASS: .............. 1 - PRINCIPAL PARK ROAD FRACTURE CRITICAL:

STRUCTURE HISTORY: ...... 1995-RAILING CONNECTIONS REPAIRED.

LOCATION

236.0 FT (71.9 M)

78.0 FT (23.8 M)

31.0 FT (9.4 M)

28.0 FT (8.5 M)

N/A 6 °

NO

HARPERS FERRY NATIONAL HISTORICAL PARK MILE POINT: ..................... 0.00 (KM PT 0.00) STATE: ................................. WEST VIRGINIA LOCATION: 1.1 MILES FROM UPPER PARK

ENTRANCE. FACILITY CARRIED: ............ SHORELINE ROAD

FEATURE INTERSECTED: .. OLD CANAL LAGOON

STRUCTURE EVALUATION SUMMARY

This prestressed concrete beam bridge is in good structural condition. There has not been any significant changed to structure since the last inspection. The main problems are deterioration of timber railing and expansion joints, runoff draining directly onto the exterior beams, and spalling at the north edge of the deck directly under the west pier expansion joint.

Corrective measures should be taken as outlined in this report to help prevent the possible development of more serious or costly problems in the future.

INSPECTION TEAM: O. AJIDE, G. GOODLIN

CONDITION ASSESSMENT:

OLUWASEUN AJIDE, FIELD TEAM LEADER 703-948-1419

REPORT REVIEW :

MARCUS MILLER, P.E., SENIOR INSPECTION ENGINEER 703-404-6252

REPORT APPROVAL: DATE: 2/28/14

JORGOMAI CEESAY, PH.D., P.E., BIP SUPERVISORY ENGINEER 703-404-6244

RECOMMENDATIONS AND ESTIMATED COSTS STRUCTURE NO. 3850-002P

A (Critical) - Structure is closed, in imminent danger of collapse, or presents a critical safety hazard.

B (Major) - Structure is seriously deficient or presents a safety hazard, but can remain in service at reduced loads or with frequent inspections.

C (Moderate) - Structure is deficient, functionally obsolete, or requires substantial repairs to prevent a serious deficiency or unsafe condition.

D (Minor) - Structure is generally in good condition. Preventative maintenance may be required.

E (Special) - Structure is under construction or reconstruction.

D226 PRIORITY OF IMPROVEMENT

ITEM

NO.

MAINTENANCE RECOMMENDATIONS

(GENERALLY NOT FLHP ELIGIBLE)

QTY. UNIT COST

UNIT

ESTIMATE

COST

PRELIM.

58.7, 59.2 APPLY CONCRETE SEALANT TO EXTERIOR BEAMS IN VICINITY OF DECK

SCUPPERS TO PROTECT FROM DETERIORATION ASSOCIATED WITH RUNOFF.

58.6 REPLACE DECAYED RAIL SECTIONS AS NECESSARY.

58.2 REPLACE BROKEN EXPANSION JOINT ARMORING.

60.6 REMOVE VINE GROWTH FROM WINGWALLS AND RAIL POSTS.

PRELIM. MAINTENANCE TOTAL :

ITEM

NO.

REHABILITATION/RECONSTRUCTION

(TYPICALLY NEEDED WITHIN 5 YEARS) QTY. UNIT UNIT

COST ESTIMATES

PRELIM. COST

REHAB. RECONSTR.

58.1 REPAIR SPALLING AT EDGE OF DECK ON FACE DIRECTLY UNDER

WEST PIER EXPANSION JOINT.

10 SF

PRELIM. REHABILITATION/RECONSTRUCTION TOTAL :

COST ESTIMATE SUMMARY

PRELIM. MAINTENANCE TOTAL:

PRELIM. REHABILITATION TOTAL:

PRELIM. RECONSTRUCTION TOTAL: ..

TOTAL ITEMIZED COSTS:

PRELIMINARY ESTIMATE TOTAL* :

(*Includes typical contract costs for mobilization, traffic control, and design/construction engineering; but does not include detour bridges, work beyond the bridge limits, or work not listed above. Estimates are approximate and are for preliminary planning purposes only; they should not be used as a complete or final engineers estimate.)

REMARKS: Cost estimates assume that the recommended actions will be combined with similar work being performed on other structures.

Consideration should be given to removing the leaning tree on the north side of the structure.

FIELD INSPECTION REPORT STRUCTURE NO. 3850-002P

G = GOOD (CODES 7 - 9) F = FAIR (CODES 5 - 6) P = POOR (CODES 0 - 4)

CONDITION RATING CODE EQUIVALENTS FOR SUB-ELEMENTS

SERIOUS CONDITION - loss of section, deterioration, spalling, or scour have seriously affected primary structural components. Local failures are possible.

Fatigue cracks in steel or shear cracks in concrete may be present.

CRITICAL CONDITION - advanced deterioration of primary structural elements. Fatigue cracks in steel or shear cracks in concrete may be present or scour may have removed substructure support. Unless closely monitored it may be necessary to close the structure until corrective action can be taken.

“IMMINENT” FAILURE CONDITION - major deterioration or section loss present in critical structural components or obvious vertical or horizontal movement affecting structure stability. Structure is closed to traffic but corrective action may return structure to light service.

FAILED CONDITION - out of service; beyond corrective action.

CONDITION RATING CODES FOR ITEMS 58 - 62, 222, 223

NOT APPLICABLE

EXCELLENT CONDITION

VERY GOOD CONDITION - no problems noted.

GOOD CONDITION - some minor problems.

SATISFACTORY CONDITION - structural elements show some minor deterioration.

FAIR CONDITION - all primary structural elements are sound but may have minor section loss, cracking, spalling, or scour.

POOR CONDITION - advanced section loss, deterioration, spalling, or scour.

N

58. DECK ITEM REFERENCE AND REMARKS

OTHER

ALIGNMENT

DEFLECTION AND/OR VIBRATION

FASCIA(E)

DIAPHRAGMS AND BRACING

TRUSSES

FLOOR BEAMS AND STRINGERS

ARCH(ES) OR SLAB(S)

GIRDERS OR BEAMS

BEARING DEVICES

59. SUPERSTRUCTURE

OTHER

DEFLECTION AND/OR VIBRATION

UTILITIES

DRAINS AND DRAINAGE

PARAPETS AND/OR RAILINGS

CURBS, SIDEWALKS, AND MEDIAN

RIDEABILITY

WEARING SURFACE

EXPANSION JOINTS

DECK SLAB

ABUTMENTS

60. SUBSTRUCTURE

1.

10.

2.

3.

4.

5.

6.

7.

8.

9.

10.

9.

8.

7.

6.

5.

4.

3.

2.

1.

PAINT

11.

G G N N N G N N G

N G

N G G F F N

N

F

G

G

58.1 MINOR CRACKING OF DECK NEAR EAST PIER JOINT, EASTBOUND

LANE OF CENTER SPAN. FORM HANGER CONSTRUCTION REMAINS

IN PLACE ON DECK UNDERSIDE. MODERATE SPALLING WITH

EXPOSED ANCHOR BOLTS AT EDGE OF DECK UNDER WEST PIER

EXPANSION JOINT, NORTH END.

58.2,7 PORTION OF HOLD-DOWN PLATE FOR DECK EXPANSION JOINT

OVER EAST PIER, IS MISSING. EVIDENCE OF MINOR PONDING OF

WATER AT NORTH END OF PIER EXPANSION JOINTS. MINOR

DETERIORATION OF CURB EXPANSION JOINTS.

58.5 MINOR CRACKING OF CURBS. MINOR SPALLING OF SOUTH CURB

EXTERIOR NEAR EAST ABUTMENT. MINOR VINE GROWTH ON

CURBS AT WEST END OF STRUCTURE. CURBS ARE STAINED FROM

WEATHERING STEEL RAIL BACKING PLATES.

DELINEATORS HAVE BEEN PLACED ALONG SOUTH SIDE OF

STRUCTURE TO PROVIDE A PEDESTRIAN WALKWAY.

58.6 STEEL-BACKED TIMBER RAIL. SEVERE DECAY OF SEVERAL RAIL

SECTIONS. WIDESPREAD MODERATE CHECKING OF RAIL. SOME

RAIL MEMBERS WERE REPLACED SINCE LAST INSPECTION.

58.7, 59.2 SCUPPERS DRAIN RUNOFF DIRECTLY ONTO EXTERIOR BEAMS;

BEAMS ARE STAINED AT THIS LOCATION. CRACKING AT BEAM

ENDS AT WEST PIER JOINT. BEAM ARE IN GOOD CONDITION,

HOWEVER.

60.4,15 MINOR CRACKING OF PIER CAPS, AND BACKWALLS (TOPS AND

FRONT FACES).

60.6 MODERATE VINE GROWTH ON SOUTHWEST, AND NORTHWEST

WINGWALLS.

BREASTWALLS OR COLUMNS1. G

PILE BENTS2. N

CAPS AND/OR BEARING SEATS3. G

BACKWALLS AND/OR BULKHEADS4. G

FOUNDATIONS5. N

WINGWALLS6. G

WEEP HOLES7. N

EXPANSION JOINTS8. G

EROSION AND/OR SCOUR9. G

SETTLEMENT OR DEFLECTION10. G

SLOPE PROTECTION11. N

OTHER 12. N

PIER(S)

WALLS AND/OR COLUMNS 13. G

PILE BENTS14. N

CAPS AND/OR BEARING SEATS15. G

FOUNDATIONS16. N

EROSION AND/OR SCOUR17. G

SETTLEMENT OR DEFLECTION18. G

OTHER 19. N

INSPECTION DATE: 10/24/13

STRUCTURE NO. 3850-002P FIELD INSPECTION REPORT

SHORELINE ROAD BRIDGE

ITEM REFERENCE AND REMARKS

AVERAGE CLEAR OPENING 8.

7. NORMAL VELOCITY

ADEQUACY OF OPENING 6.

5. OTHER

4. WATERWAY OBSTRUCTIONS

CHANNEL PROTECTION3.

EROSION AND/OR SCOUR2.

ALIGNMENT1.

61. CHANNEL 8

G G G G N

LOW

SUFF

2 FT.

9. STREAM BED COMPOSITION :

SILT, GRAVEL, SAND

222. APPROACHES 7

OTHER 9.

ALIGNMENT 8.

SIGNS7.

SETTLEMENT 6.

EROSION5.

SURFACING4.

APPROACH GUARDRAIL 3.

2. RELIEF JOINTS

APPROACH SLABS1. G

N G N G G N G N

223. RETAINING WALL N

OTHER 6.

SETTLEMENT OR DEFLECTION5.

EROSION AND/OR SCOUR4.

FOUNDATION3.

WEEP HOLES2.

1. WALL

36. TRAFFIC AND SAFETY FEATURES

APPROACH GUARDRAIL ENDSD.

APPROACH GUARDRAILSC.

TRANSITIONSB.

BRIDGE RAILINGSA. 1

222.1 MINOR LONGITUDINAL CRACKING OF END PORTIONS OF

APPROACH SLABS. APPROACH SLABS PAVEMENT WIDENED ON

SOUTH SIDE TO ALLOW FOR PEDESTRIAN WALKWAY ON NORTH

SHOULDER.

222.3 STEEL BACKED TIMBER GUARDRAIL AT BOTH APPROACHES. END

OF NORTH RAIL IS SPLIT AT WEST APPROACH. TOP OF END POST,

SOUTH RAIL, EAST APPROACH IS SPLIT. MINOR TO MODERATE

CHECKING OF EAST APPROACH RAILS.

222.5,6 MINOR SETTLEMENT OF SOIL SHOULDERS AT BOTH APPROACHES

ON SOUTH SIDE DUE TO FOOT TRAFFIC.

TRAFFIC SAFETY RATING CODES

N

Does not meet standards or a safety feature is required and none is provided.

Meets currently acceptable standards.

Not applicable or a safety feature is not required.

STRUCTURE LOAD RATING STRUCTURE NO. 3850-002P

TRUCK TYPE

INVENTORY RATING (NORMAL TRAFFIC) OPERATING RATING (MAXIMUM LOAD)

TONS METRIC TONS TONS METRIC TONS

H 27 25 45 41

HS 36 33 60 55

TYPE 3 34 31 57 52

TYPE 3S2 44 40 73 66

TYPE 3-3 50 46 84 76

DESIGN LOADING: HS20 (MS18)

X CAPACITY MEETS OR EXCEEDS DESIGN LOAD

CAPACITY IS LESS THAN DESIGN LOAD

ORIGINAL LOAD RATING CALCULATION APPLICABLE

ORIGINAL LOAD RATING CALCULATION REVISED

DATE OF LOAD RATING CALCULATION:

LOAD RATING CONTROLLED BY:

REMARKS: RATING IS BASED ON DESIGN LOAD OF STRUCTURE.

STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 3850-002P

STRUCTURE IDENTIFICATION

(201) PARK: HARPERS FERRY NATIONAL HISTORICAL PARK (1) STATE: ....................................... 543 - WEST VIRGINIA (WV)

(202) STRUCTURE NAME: .......... SHORELINE ROAD BRIDGE (2) STATE HWY. AGENCY DIST:

(203) STRUCTURE KIND: ............1 - BRIDGE (3) COUNTY CODE: ........................ 037 - JEFFERSON

(204) STRUCTURE NUMBER: ..... 3850-002P (4) CITY/PLACE CODE:

(205) NPS REGION: .................... 2 - NATIONAL CAPITAL (5) INVENTORY ROUTE:

(206) ROUTE CODE NUMBER: ... 1 (6) FEATURES INTERSECTED:....... OLD CANAL LAGOON

(207) ROAD SECTION NO: ..........002P (7) FACILITY CARRIED: .................. SHORELINE ROAD

(208) NPS ROAD CLASS: ............ 1 - PRINCIPAL PARK ROAD (8) STATE STRUCTURE NO: .......... 3850002P0000000

(209) WITHIN NPS BNDRY?: .......YES (9) LOCATION: ................................ 1.1 MILES FROM UPPER PAR

(210) OPERATING UNIT: .............PARK (10) INV. RTE. - MIN. VERT. CLR: .. 99.99 FT (99.99 M)

(211) PROJECT NO(S): ................14-1(1) (11) MILE POINT: ............................. 0.00 (KM PT 0.00)

(212) DRAWING NUMBERS: ....... 00000 (27) YEAR BUILT:

(21) MAINTAINED BY: ................. 66 - NATIONAL PARK SERVICE (106) YEAR RECONSTRUCTED: .... N/A

(22) OWNER: ............................... 66 - NATIONAL PARK SERVICE (20) TOLL: ........................................ 3 - FREE ROAD

(37) HISTORICAL DESIGNATION: .. 5 - NOT ELIGIBLE

STRUCTURE DESCRIPTION, FOUNDATION, AND DECK TYPE

(43A) MAIN STR. MATERIAL: ..

(43B) MAIN STR. TYPE:

(45) NO. OF MAIN SPANS:

(48) MAX. SPAN LENGTH:

(49) STRUCTURE LENGTH:

(216A) ABUTMENT #1 FDN:

(216B) ABUTMENT #2 FDN:

(217A) PREDOM. PIER FDN.: ..

(217B) SECOND. PIER FDN: ...

(107) DECK TYPE:

5 - PRESTRESSED CONCRETE

02 - STRINGER/MULTI-BEAM or GIRDER

78.0 FT (23.8 M)

236.0 FT (71.9 M)

2 - SPREAD FTG ON BEARING MAT'L

2 - SPREAD FTG ON BEARING MAT'L

2 - SPREAD FTG ON BEARING MAT'L

2 - SPREAD FTG ON BEARING MAT'L

1 - CONCRETE CAST-IN-PLACE

(44A) APPR. STR. MATERIAL: ........ 0 - OTHER

(44B) APPR. STR. TYPE: ................ 00 - OTHER

(46) NO. OF APPROACH SPANS: .. 0

(108) WEAR SURFACE/PROTECT SYSTEM:

A) TYPE WEARING SURFACE: .. 0 - NONE

B) TYPE MEMBRANE: ................. 0 - NONE

C) TYPE PROTECTION: .............. 0 - NONE

(218) IS SALT USED?: ..................... YES

LOAD RATING AND POSTING

(31) DESIGN LOAD: ................. 5 - HS20 (MS18) (41) LOAD RESTRICTION: ......... A - OPEN, NO RESTRICTION

(66) INVENTORY RATING: ...... 36.0 TONS (32.7 METRIC TONS) (70) BRIDGE POSTING: .............. 5 - NO POSTING REQUIRED

(64) OPERATING RATING: ...... 60.1 TONS (54.5 METRIC TONS)

INSPECTION DATES

(90) INSPECTION DATE: 10/13 (91) FREQ. OF INSP: 24 MONTHS (92 / 93) CRITICAL FEATURE INSPECTION (CFI):

(219) ADD. STUDIES NEEDED: N - 0 - NONE (A) FRACTURE CRITICAL: ... NO

INSP. EVERY: MONTHS - LAST INSP. : (220) SPECIAL STUDY TYPE: 0 - NONE

(B) UNDERWATER: .............. NO

(221) SPECIAL STUDY DATE: INSP. EVERY: MONTHS - LAST INSP. :

(C) SPECIAL INSPECTION: .. NO

INSP. EVERY: MONTHS - LAST INSP. :

STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 3850-002P

GEOMETRY, TRAFFIC, AND NAVIGATIONAL DATA

(16) LATITUDE: ............................. (51) CURB TO CURB WIDTH: ........... 28.0 FT (8.5 M)

(17) LONGITUDE: ......................... (52) DECK WIDTH: ............................ 31.0 FT (9.4 M)

(19) DETOUR LENGTH: ............... 4 MI (6 KM) (32) APPR. ROADWAY WIDTH: ........ 28.0 FT (8.5 M)

(28A) LANES ON STRUCT: .......... 02 (213) APPR. PAVEMENT WIDTH: ..... 22.0 FT (6.7 M)

(28B) LANES UNDER STRUCT: ... 00 LEFT SHOULDER: .................. 3.0 FT (0.9 M)

(42A) SERVICE ON: ..................... 1 - HIGHWAY RIGHT SHOULDER: ................ 3.0 FT (0.9 M)

(42B) SERVICE UNDER: .............. 5 - WATERWAY (33) BRIDGE MEDIAN: ....................... 0 - NO MEDIAN

(29) AVG. DAILY TRAFFIC: .......... 1 (34) SKEW ANGLE: ............................ 6 °

(30) YEAR OF ADT: ...................... 2007 (35) DECK FLARE?: ........................... NO

(114) FUTURE ADT: ..................... 2 (47) TOTAL HORIZ. CLEARANCE: .... 28.0 FT (8.5 M)

(115) YEAR OF FUTURE ADT: ..... 2027 (50) SIDEWALKS:

(101) PARALLEL STRUCTURE: ... N - NONE LEFT : ...................................... 0.0 FT (0.0 M)

(38) NAVIGATION CONTROL?: ... 0 RIGHT : ................................... 0.0 FT (0.0 M)

(39) VERTICAL CLEARANCE: ...... 0.0 FT (0.0 M) (214) BRIDGE RAIL TYPE:

(40) HORIZ. CLEARANCE: ........... 0.0 FT (0.0 M) RAIL CONFIGURATION: ......... 1 - FULL HEIGHT (NO PARAPE

(111) ABUT. OR PIER PROT: ....... 1 - NAV PROTECTION NOT REQUIRED MATERIAL: .............................. 7 - TIMBER

DESIGN TYPE: ........................ 1 - CONTINUOUS RAIL LATERAL UNDERCLEARANCE:

(55) RIGHT: ....................... 0.0 FT (0.0 M) (215) BRIDGE RAIL HEIGHT: ............ 2.90 FT (0.88 M)

(56) LEFT: ......................... 0.0 FT (0.0 M) (53) MIN. VRT. CLEAR. OVER DECK: 99.99 FT (99.99 M)

(54) MIN. VRT. UNDERCLEARANCE: 0.00 FT (0.00 M)

CONDITION AND APPRAISAL DATA, PROPOSED IMPROVEMENTS, AND COST

(58) DECK:

(59) SUPERSTRUCTURE:

(60) SUBSTRUCTURE:

(61) CHANNEL:

(62) CULVERT: ........................... N

(222) APPROACHES:

(223) RETAINING WALL: ...........N

(36) TRAFFIC SAFETY FEAT: ... 1111

(75A) TYPE OF WORK:

(75B) WORK DONE BY:

(76) IMPROVEMENT LENGTH: ..

(67) STRUCTURAL EVALUATION:

(68) DECK GEOMETRY:

(69) UNDERCLEARANCES:

(71) WATERWAY ADEQUACY:

(72) APPROACH ALIGNMENT:

(113) SCOUR CRITICAL:

(225) PURPOSE OF IMPROVEMENT:

(226) PRIORITY OF IMPROVEMENT:

(227) MAINTENANCE COST:

(228) REHAB./RECONSTR. COST: ...

(229) CONSTRUCTION COST:

N

8 - Stable; scour above top of fo

2 - REHAB/RECONSTRUCTION

D - MINOR

$0

ADDITIONAL INFORMATION

(230) STRUCTURE HISTORY:

1995-RAILING CONNECTIONS REPAIRED.

(231) ADDITIONAL CONSIDERATIONS:

(330) ADDITIONAL CONFIG. INFO.:

APPENDIX STRUCTURE NO. 3850-002P

PHOTOGRAPHS STRUCTURE NO. 3850-002P

PHOTO #1 - LOOKING EAST TOWARD HARPERS FERRY

PHOTO #2 - NORTH (UPSTREAM) SIDE

PHOTO #3 - GENERAL TOP SIDE VIEW OF STRUCTURE LOOKING WEST

PHOTO #4 - GENERAL UNDERSIDE VIEW LOOKING WEST

PHOTO #5 - GENERAL VIEW OF EXPANSION

JOINT OVER ABUTMENT, EAST ABUTMENT

SHOWN

PHOTO #6 - TYPICAL CRACKING IN TOP OF

ABUTMENT BACKWALL

PHOTO #7 - BROKEN AND MISSING SECTION

OF EXPANSION JOINT ARMORING OVER EAST

PIER

PHOTO #8 - CLOSE-UP VIEW OF BROKEN AND

MISSING SECTION OF EXPANSION JOINT

ARMORING OVER EAST PIER

PHOTO #9 - DEBRIS ACCUMULATION AND VEGETATION GROWTH

ALONG NORTH CURB AT EXPANSION JOINT OVER EAST PIER

PHOTO #10 - SETTLEMENT OF SHOULDER AT EAST APPROACH TO

PEDESTRIAN WALKWAY

PHOTO #11 - DECAY OF NORTH TIMBER RAIL SECTION IN WEST SPAN

PHOTO #12 - TYPICAL SPLIT IN TIMBER RAIL POST

PHOTO #13 - EAST END OF SOUTH APPROACH GUARDRAIL; NOTE

ANCHOR BOLT OUT OF POST

PHOTO #14 - WATER STAINS ON EXTERIOR OF BEAMS DUE TO

SCUPPER RUNOFF, NORTH SIDE SHOWN

PHOTO #15 - SPALLING OF SOUTH CURB

EXTERIOR NEAR EAST ABUTMENT

PHOTO #16 - DETERIORATION OF BEAM ENDS

AT WEST PIER JOINT, NORTH SIDE

PHOTO #17 - SPALLING AT EDGE OF DECK DIRECTLY UNDER WEST

PIER EXPANSION JOINT WITH EXPOSED ANCHOR BOLTS (PHOTO

FROM 11/4/2009 INSPECTION)

PHOTO #18 - CLOSE-UP OF PREVIOUS PHOTO (PHOTO FROM 11/4/2009

INSPECTION)

PHOTO #19 - GENERAL VIEW OF WEST ABUTMENT CRACKING

PHOTO #20 - CRACKING OF FRONT FACE OF WEST ABUTMENT

BACKWALL

PHOTO #21 - TYPICAL VINE GROWTH ON WINGWALLS, SOUTHWEST

WINGWALL SHOWN

PHOTO #22 - MAP CRACKING WITH EFFLORESCENCE ON SOUTHEAST

WINGWALL

PHOTO #23 - GENERAL VIEW OF EAST PIER

PHOTO #24 - GENERAL VIEW OF PIER BEARINGS

PHOTO #25 - VIEW FROM BRIDGE LOOKING UPSTREAM

PHOTO #26 - VIEW FROM BRIDGE LOOKING DOWNSTREAM

File details come from the government source that posted it. Updated .