16 SIR 16R00176_Atch 2_DWGS_ZMA-D-1404046 - 13May16.pdf
PDF 1 MB Posted
- Solicitation number
- DTFAEN-16-R-00176
About this file
16 SIR 16R00176_Atch 2_DWGS_ZMA-D-1404046 - 13May16 (pdf)
View the file
Other files
Show all 30
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FO
TNEMT
R A
P E
D
N
OI
T
AT
RO
PSNART
U N
IT
E
D
STATES OF
AM
ER
I C A
8 1234567
F
IL
E
:1
:0
A M
D a n ie l D o b y
H H
8 1234567
G
F
E
D
C
B
A
G
F
E
D
C
B
A
REV DESCRIPTION JCN
DATE
REDLINE
DATE
APPROVED
APVD
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
SUBMITTED BY APPROVED BY
JCN
DRAWN
CHECKED
REV
ISSUED BY DATE
DRAWING NO
DESIGNED
REVIEWED BY
SCALES SHOWN FOR 22" X 34" SHEET. ADJUST SCALES FOR OTHER SIZES.
ATLANTA NAS
EASTERN SERVICE AREA ATLANTA, GA
ENGINEERING
JD
JD
JOE DOBY, RA
GENERAL
COVER SHEET
1PAGE OF 10
ZMA-D-1404046-
FOR OFFICIAL USE ONLY
PUBLIC AVAILABILITY TO BE DETERMINED UNDER 5 USC 552
FAA ATO
DESIGN ENGINEER, ENROUTE
ENROUTE
1404046
MD/JS
N
NOT TO SCALE
(ZMA ARTCC)
3/31/2016
MANAGER, ENROUTE
JOE SCHMITT
DORAL BLVD
DORAL BLVD
N W
T H
V
P A
L M
E T
O
E X
W Y
NW 74TH ST
W
W
K E E C
H O B E E
R
D
N W
S
O U T
H
R I
V
R
D
NW 58TH ST
NW 74TH ST
N W
N
MIAMI SPRINGS
W 21ST ST
NW 72ND ST
M I
L
MIAMI FLORIDA
G001
SITE
VICINITY MAP
MIAMI, FL 33166-3724
7500 NW 58TH STREET
MIAMI ARTCC (ZMA)
POWER SERVICE BUILDING AND
MIAMI, FL
PARTIAL ROOF REPLACEMENT
AUTOMATION WING
POWER SERVICE BUILDING AND
ZMA - MIAMI ARTCC
AUTOMATION WING PARTIAL ROOF REPLACE
FOR BID)
(FINAL DESIGN SUBMITTAL
ZMA-D-1404046-G001.dgn 5/12/2016 8:16:10 AM
8 1234567
F
IL
E
:1
:5
P
D a n ie l D o b y
H
G
F
E
D
C
B
A
8 1234567
DRAWN
CHECKED
REVDRAWING NO
ENGINEERING
JD
C
B
A
REV DESCRIPTION JCN
DATE
REDLINE
DATE
APPROVED
APVD
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
SUBMITTED BY APPROVED BY
JCNISSUED BY DATEDESIGNED
REVIEWED BY
ATLANTA NAS
EASTERN SERVICE AREA ATLANTA, GA
JD
JOE DOBY, RA
FOR OFFICIAL USE ONLY
PUBLIC AVAILABILITY TO BE DETERMINED UNDER 5 USC 552
H
G
F
E
D
ENROUTE
MD/JS
DESIGN ENGINEER, ENROUTE
8 1234567
F
IL
E
:1
D a n ie l D o b y
H
G
F
E
D
C
B
A
8 1234567
DRAWN
CHECKED
REVDRAWING NO
ENGINEERING
JD
C
B
A
REV DESCRIPTION JCN
DATE
REDLINE
DATE
APPROVED
APVD
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
SUBMITTED BY APPROVED BY
JCNISSUED BY DATEDESIGNED
REVIEWED BY
ATLANTA NAS
EASTERN SERVICE AREA ATLANTA, GA
JD
H
G
F
E
D
ENROUTE
MD/JS
DESIGN ENGINEER, ENROUTE
DRAWING NO. REV. DATE DESCRIPTION
BREAK LINES
A
A012
A
A012
E1
A012
SECTION DESIGNATION
SECTION DESIGNATION
SECTION IS CUT
SHEET ON WHICH
ELEVATION IS DRAWN
SHEET ON WHICH
SECTION IS CUT
SHEET ON WHICH
04’ 4’
E1
A012
ELEVATION IS DRAWN
SHEET ON WHICH
04’ 4’
E1
A012
ELEVATION IS DRAWN
SHEET ON WHICH
04’ 4’
E1
A012
ELEVATION IS DRAWN
SHEET ON WHICH
04’ 4’
GENERAL LEGEND
E1
A012
ELEVATION IS DRAWN
SHEET ON WHICH
04’ 4’
A012
DETAIL NUMBER
A010
A
A010
E1
A012
SECTION DESIGNATION
DETAIL DESIGNATION
ELEVATION DESIGNATION
SECTION IS DRAWN
SHEET ON WHICH
IS DRAWN OR SCHEDULED
SHEET ON WHICH DETAIL
DETAIL IS DRAWN
SHEET ON WHICH
EQUIPMENT ROOM
04’ 4’ 8’
SCALE: 1/4" = 1’-0"
GRAPHIC SCALE
NORTH ARROW
ROOM NAME & NUMBER
EXISTING WORK, UON
NEW WORK, UON
CONTRACTOR, UON
DEMOLITION BY
DETAIL TITLE REFERENCE
SECTION TITLE REFERENCE
DETAIL REFERENCE
SECTION CUT
PARTIAL SECTION CUT
ELEVATION REFERENCE
NOTESDRAWING LIST
G
H
I
J
K
L
M
N
R
S
T
U
V
W
A
B
C
F P
D
E O X
Y
OD OUTSIDE DIAMETER
OC ON CENTER
OA OUTSIDE AIR
NTS NOT TO SCALE
NPT NATIONAL PIPE THREAD
NOM NOMINAL
NIC NOT IN CONTRACT
MIN MINIMUM
MFG MANUFACTURER
MCC MOTOR CONTROL CENTER
MBH 1000 BTU PER HOUR
MAX MAXIMUM
LWT LEAVING WATER TEMPERATURE
LBS POUNDS
LAT LEAVING AIR TEMPERATURE
KW KILOWATTS
KVA KILOVOLT AMPERE
JB JUNCTION BOX
IW INDUSTRIAL WATER
INV INVERT
IN INCH
ID INSIDE DIAMETER
HZ HERTZ
HWS HEATING WATER SUPPLY
HWR HEATING WATER RETURN
HWC HW CIRCULATION LOOP
HW DOMESTIC HOT WATER
HU HUMIDIFIER
HTE HEAT TRACE ELEMENT
HS HUMIDITY SENSOR
HR HOUR
HP HORSE POWER
HORIZ HORIZONTAL
HC HEATING COIL
HB HOSE BIBB
GV GATE VALVE
GPM GALLONS PER MINUTE
GPH GALLONS PER HOUR
GND GROUND
GFI GROUND FAULT INTERRUPTER
GALV GALVANIZED
GA GAUGE
G NATURAL GAS
FT FEET
FPM FEET PER MINUTE
FM FLOW METER/SENSOR
FLG FLANGE
FFE FINISHED FLOOR ELEVATION
FD/SD FIRE/SMOKE DAMPER
FD FIRE DAMPER OR FLOOR DRAIN
FCV FLOW CONTROL VALVE
FCO FLOOR CLEAN OUT
FCU FAN COIL UNIT
STANDARD ABBREVIATIONS
YH YARD HYDRANT
XFMR TRANSFORMER
XFER TRANSFER
WWF WELDED WIRE FABRIC
W/O WITHOUT
WC WATER COLUMN
WB WET BUILD TEMPERATURE
W/ WITH
W WATTS
VS VIBRATION SENSOR
VIF VERIFY IN FIELD
VERT VERTICAL
VD VOLUME DAMPER
VCT VINYL COMPOSITE TILE
TERMINAL
VAV VARIABLE AIR VOLUME
V VOLTS
UNO UNLESS NOTED OTHERWISE
UH UNIT HEATER
TYP TYPICAL
TS TEMPERATURE SENSOR
TRANS TRANSVERSE
TOP TOP OF PIPE
TOD TOP OF DUCT
TI TEMPERATURE INDICATOR
TEMP TEMPERATURE
T THERMOSTAT
STR STRUCTURE
STD STANDARD
SPEC SPECIFICATIONS
SIM SIMILAR
SF SUPPLY FAN
SCH SCHEDULE
SAP SOUND ABSORBING PANEL
SAN SANITARY
SA SUPPLY AIR
RV REFRIGERANT VENT
RPM REVOLUTIONS PER MINUTE
RHC REHEAT COIL
RGS RIGID GALVANIZED STEEL
REV REVISION OR REVERSE
REQ’D REQUIRED
REINF REINFORCING
REF REFERENCE
REC RECEPTACLE
RCP REFLECTED CEILING PLAN
RA RETURN AIR
R RADIUS
PSI POUNDS PER SQUARE INCH
PSF POUNDS PER SQUARE FOOT
PS PRESSURE SENSOR
PRV PRESSURE REDUCING VALVE
POC POINT OF CONNECTION
PI PRESSURE INDICATOR
PHC PREHEAT COIL
PH PHASE
EWT ENTERING WATER TEMPERATURE
EMT ELECTRICAL METAL TUBING
ELEC ELECTRIC/ELECTRICAL
ELEV ELEVATION
EF EXHAUST FAN
EAT ENTERING AIR TEMPERATURE
DPS DP SENSOR
DP DIFFERENTIAL PRESSURE
DO DIGITAL OUTPUT
DN DOWN
DISC DISCONNECT
DIA DIAMETER
DI DIGITAL INPUT
DDC DIRECT DIGITAL CONTROL
DC DIRECT CURRENT
DBL DOUBLE
DB DRY BULB TEMPERATURE
D DRAIN
COPPER
CWS CHILLED WATER SUPPLY
CWR CHILLED WATER RETURN
CW DOMESTIC COLD WATER
CU CONDENSING UNIT
CTS COOLING TOWER WATER SUPPLY
WATER RETURN
CTR CENTER OR COOLING TOWER
TECHNICAL REPRESENTATIVE
COTR CONTRACTING OFFICERS
CONT CONTINUOUS
COND CONDENSATE
CONC CONCRETE
COL COLUMN
CO CLEAN OUT
CMU CONCRETE MASONRY UNIT
CL CENTER LINE
CKT CIRCUIT
CIRC CIRCULATING
CIP CAST IN PLACE
CI CAST IRON
CFM CUBIC FEET PER MINUTE
CD CONDENSATE DRAIN
CC COOLING COIL
BWV BACK WATER VALVE
BV BALL VALVE
BTUH BTU PER HOUR
BTU BRITISH THERMAL UNIT
BSMT BASEMENT
BOTT BOTTOM
BOP BOTTOM OF PIPE
BOD BOTTOM OF DUCT
BLDG BUILDING
BKR BREAKER
BFV BUTTERFLY VALVE
BFP BACK FLOW PREVENTER
BF BLIND FLANGE
AWG AMERICAN WIRE GAUGE
AUX AUXILIARY
ASSY ASSEMBLY
ARCH ARCHITECT/ARCHITECTURAL
APROX APPROXIMATELY
AO ANALOG OUTPUT
AHU AIR HANDLING UNIT
AFM AIR FLOW METER/SENSOR
AFF ABOVE FINISHED FLOOR
AD ACCESS DOOR
AC ALTERNATING CURRENT
A AMP
MANAGER, ENROUTE
JOE SCHMITT
G002ZMA-D-1404046-
1404046
FLORIDA(ZMA ARTCC)MIAMI
3/31/2016
GENERAL
LEGEND, ABBREVIATIONS & CODE ANALYSIS
CODE ANALYSIS
CONSTRUCTION, ETC.
FIRE ALARM SHUTDOWNS NECESSARY FOR
DEBRIS REMOVAL, TESTING, ELECTRICAL AND
COSTS MAY INCLUDE, BUT ARE NOT LIMITED TO,
BY THE GENERAL CONTRACTOR. THESE BOURNE
ANY AND ALL COORDINATION COSTS MUST BE 3.
OF THE WORK BEING PERFORMED.
THE FAA COR IN WRITING 48 HOURS IN ADVANCE
REQUESTS FOR CIRCUIT BREAKER OPERATION TO
BREAKERS. CONTRACTOR SHALL SUBMIT ALL
ONLY FAA PERSONNEL MAY OPERATE CIRCUIT 2.
OF LIVES.
OUTAGE MAY RESULT IN ACCIDENTS OR LOSS
AIR ROUTE TRAFFIC CONTROL CENTER, ANY
AS THIS IS A FULLY OPERATIONAL
SYSTEMS OR THE LIGHTNING PROTECTION SYSTEM.
WORKING ON ANY OF THE ELECTRICAL POWER
EXTREME CAUTION MUST BE PRACTICED WHEN 1.1.
OCCUPANCY CLASSIFICATION:2.
3. CONSTRUCTION TYPE:
REGULATIONS:
APPLICABLE CODES AND
NFPA 101, EXISTING BUSINESS
IBC, GROUP B
4. AUTOMATIC SPRINKLER SYSTEM PROVIDED THROUGHOUT.
7. DEAD END LIMIT: 50 FEET (NFPA 101.38.2.5.2.1).
5. TRAVEL DISTANCE LIMIT: 300 FEET (NFPA 101,38.2.6.1)
6. COMMON PATH OF TRAVEL LIMIT: 100 FEET (NFPA 101.38.2.5.3.1)
TYPE II B IBC ( ADMINISTRATION WING)
TYPE II A IBC ( CONTROL WING AND AUTOMATION WING)
8. SEISMIC DESIGN CATEGORY : C
2013 EDITION, ALTERATIONS CODE
ASME A17.1, SP CODE FOR ELEVATORS AND ESCALATORS,
NFPA 72, NATIONAL FIRE ALARM CODE, 2013 EDITION
NFPA 13, INSTALLATION OF SPRINKLER SYSTEMS, 2013 EDITION
INTERNATIONAL MECHANICAL CODE, 2012 EDITION
NFPA 70 (NATIONAL ELECTRICAL CODE (NEC), 2014
(29 CFR 1910 AND 1926 - CURRENT ISSUE)
GENERAL INDUSTRY SAFETY & HEALTH STANDARDS
OCCUPATIONAL SAFETY & HEALTH ADMINISTRATION (OSHA)
BUILDINGS AND FACILITIES (2004)
ABAAS, ADA AND ABA ACCESSIBILITY GUIDELINES FOR
NFPA 101 - LIFE SAFETY CODE, 2012 EDITION
INTERNATIONAL BUILDING CODE (IBC), 2012 EDITION
POWER SERVICES BUILDING AND
AUTOMATION WING PARTIAL ROOF REPLACE
PAGE OF 10
N
2/9/2016
2/9/2016
2/9/2016
3/31/2016
3/31/2016
3/31/2016
3/31/2016
3/31/2016
3/31/2016
3/31/2016
ZMA-D-1404046-E501
ZMA-D-1404046-E102
ZMA-D-1404046-E101
ZMA-D-1404046-A502
ZMA-D-1404046-A501
ZMA-D-1404046-A103
ZMA-D-1404046-A102
ZMA-D-1404046-A101
ZMA-D-1404046-G002
ZMA-D-1404046-G001
LIGHTNING PROTECTION DETAILS
LIGHTNING PROTECTION PLAN
LIGHTNING PROTECTION DEMOLITION PLAN
ROOF DETAILS
ROOF DETAILS
ROOF PLAN
ROOF DEMOLITION PLAN
CONSTRUCTION STAGING PLAN
DRAWING INDEX, ABBREVIATIONS, LEGEND & CODE ANALYSIS
COVER SHEET
ZMA-D-1404046-G002.dgn 5/4/2016 2:15:58 PM
F
IL
E
:1
:2
D a n ie l D o b y
H H
8 1234567
G
F
E
D
C
B
A
G
F
E
D
C
B
A
REV DESCRIPTION JCN
DATE
REDLINE
DATE
APPROVED
APVD
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
SUBMITTED BY APPROVED BY
JCN
DRAWN
CHECKED
REV
ISSUED BY DATE
DRAWING NO
DESIGNED
REVIEWED BY
SCALES SHOWN FOR 22" X 34" SHEET. ADJUST SCALES FOR OTHER SIZES.
ATLANTA NAS
EASTERN SERVICE AREA ATLANTA, GA
ENGINEERING
JD
JD
JOE DOBY, RA
FOR OFFICIAL USE ONLY
PUBLIC AVAILABILITY TO BE DETERMINED UNDER 5 USC 552
P L
N
NOT TO SCALE
CONSTRUCTION STAGING PLAN
CONSTRUCTION STAGING PLAN NOTES
NOTE
SECURITY FENCE
ASPHALT PAVEMENT
NW 58TH STREET
ASPHALT PAVEMENT
PARKING
CONTRACTOR
LOADING DOCK
E N
U E
ASPHALT PAVEMENT
GUARD HOUSE
P L
ELEVATOR
FREIGHT
MAIN ENTRANCE
SECURITY GATE
P A
L M
E T
P R
E S
S W
A Y
IN
T R
U S
IO
N
E S
T
IM
A T
E D
A S
P H
A L
V E
M E
N T
S .R
P
A L
M E
T
P R
E S
S W
A Y
F U
T U
IN
E
ASPHALT PAVEMENT
STAGING AREA
CONSTRUCTION
XXXXXXXXXXXX
XXXXXXXXX
XXXXXX
X X
X X
X
XXXXXXX
X
XX
X X
X X
X
X
XX
X X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X X
X X
X X X X X
X
X X X
X
X X
X
X X
X X
X X
X X
X X
X X
X X
X
X
X
X
X X
X X
X X X X X X
X X
X X
X X
X
XXXX
XX
X
X
X
X
X
X X
X
X
X
XXXX
X
X
XX
X X
WAREHOUSE
BUILDING
PCS
A S
P H
A
V E
M E
N T
VERIFY EXISTING SITE CONDITIONS AT TIME OF BID.
CAFETERIA
WING
CONTROL
AREA
TELCO
MAIN ARTCC BUILDING
GARAGE
STORAGE
BUILDING
AUTOMATION
WING
CENTER
CHILD CARE
OFFICE
COORDINATION
NAS
ADMIN WING
POLE
FLAG
ZMA-D-1404046-
DESIGN ENGINEER, ENROUTE
ENROUTE
MD/JS
(ZMA ARTCC)
MANAGER, ENROUTE
JOE SCHMITT
ARCHITECTURAL
CONSTRUCTION STAGING PLAN & NOTES
MIAMI FLORIDA
A101
A101
14040463/31/2016
PUBLIC AND MAY RESULT IN CRIMINAL CHARGES AGAINST THE CONTRACTOR.
LOSS OF THIS EQUIPMENT FOR ANY AMOUNT OF TIME WILL JEOPARDIZE SAFETY OF THE FLYING
IMMEDIATELY OF DAMAGE OR DISRUPTION OF ELECTRICAL SERVICES.
SUCH AS BUT NOT LIMITED TO DISRUPTION OF POWER TO EQUIPMENT. CONTRACTOR SHALL NOTIFY COR
FROM PHYSICAL OR ELECTRICAL DAMAGE AS A RESULT OF INCIDENTAL OR ACCIDENTAL NEGLIGENCE
CONTRACT. CONTRACTOR SHALL BE RESPONSIBLE FOR CONTINUOUS PROTECTION OF THIS EQUIPMENT
C.5 EXISTING FAA AIR TRAFFIC EQUIPMENT SHALL REMAIN OPERATIONAL THROUGHOUT DURATION OF THIS
WORK SHALL BE COORDINATED WITH COR. DISRUPTION OF THIS FACILITY SHALL NOT BE PERMITTED.
C.4 CONTRACTOR SHALL USE GREAT CARE AND CAUTION WHILE WORKING IN ALL AREAS OF THIS FACILITY.
COORDINATE WORK WITHIN THE BUILDING IN ADVANCE WITH COR.
C.3 FAA ESCORTS MAY BE REQUIRED FOR CONSTRUCTION PERSONNEL WORKING WITHIN THE BUILDING.
C.2 SITE IS A SECURE AREA AND CONSTRUCTION PERSONNEL SHALL REMAIN IN CONSTRUCTION AREAS.
THE BUILDING. CONTRACTORS VEHICLES SHALL BE MARKED.
SUPERVISORY PERSONNEL SHALL BE RESPONSIBLE FOR CONDUCT OF THEIR PERSONNEL WHILE IN
TEMPORARY SECURITY BADGES SHALL BE ISSUED TO CONSTRUCTION PERSONNEL. CONTRACTOR’S
C.1 AN ADVANCE LIST AND WEEKLY LOG OF CONTRACTOR’S PERSONNEL SHALL BE PROVIDED TO COR.
C. FAA SECURITY REQUIREMENTS.
B.1 CONTRACTOR’S PARKING SHALL BE COORDINATED WITH COR.
B. CONTRACTOR PARKING.
POWER SERVICES BUILDING AND
AUTOMATION WING PARTIAL ROOF REPLACE
PAGE OF 10
SEE A102
AREA OF WORK
X X
XX
8:00 AM AND 2:00 TO 4:00 PM.
FAA EMPLOYEES SHIFT CHANGES TO AVOID CONGESTION. FAA SHIFT CHANGES OCCUR AT 6:30 TO
A.4 DELIVERIES SHALL BE SCHEDULED AND APPROVED IN ADVANCE WITH COR AND AT TIMES OTHER THAN
FAA DELIVERIES.
A.3 CONTRACTOR SHALL KEEP LOADING DOCK AND CAFETERIA ENTRANCE ACCESSIBLE AT ALL TIMES FOR
PERSONS NEAR CONSTRUCTION AREAS.
SITE. PROVIDE NECESSARY BARRICADES, LIGHTS, SIGNAGE AND FENCING TO PROTECT, WARN AND DIRECT
A.2 PROVIDE SIGNAGE TO INDICATE ACCESS ROUTE FOR CONSTRUCTION EMPLOYEES AND DELIVERIES ON
SECURITY GATE.
A.1 CONTRACTOR’S VEHICLES, PEDESTRIAN AND DELIVERIES TO SITE SHALL BE THROUGH MAIN ENTRANCE
A. CONSTRUCTION ACCESS.
BE COORDINATED WITH SITE PERSONNEL VIA COR; PARTICULARLY IN CONJUNCTION WITH ONGOING PROJECTS.
CONSTRUCTION ACCESS, PARKING, OFFICES AND EXTENT/SIZE OF CONSTRUCTION STAGING AREA SHALL
DIVISION 1 REQUIREMENTS.
THESE NOTES PARAPHRASE DIVISION 1 REQUIREMENTS AND ARE NOT INTENDED TO MODIFY OR REPLACE
OF THE MAJOR REQUIREMENTS STATED IN "DIVISION 1 GENERAL REQUIREMENTS" OF THE SPECIFICATIONS.
THE FOLLOWING NOTES AND ACCOMPANYING "CONSTRUCTION STAGING PLAN" GRAPHICALLY REPRESENT MANY
I.1 SEE SPECIFICATION SECTION 01 71 33 FOR SEVERE WEATHER PLAN SUBMITTAL REQUIREMENTS.
I. SITE RESTORATION.
H. ADDITIONAL GENERAL REQUIREMENTS ARE LISTED IN THE SPECIFICATIONS.
SHALL NOT BE PERMITTED IN FAA OCCUPIED AREAS UNLESS APPROVED IN WRITING BY COR.
G.3 NO WELDING EQUIPMENT SHALL BE POWERED BY THE FACILITY ELECTRICAL SYSTEM. WELDING
COORDINATE CONSTRUCTION ACTIVITY SO AS NOT TO INTERFERE WITH FUNCTIONS OF THE ARTCC.
G.2 ARTCC IS A 24 HOUR 7 DAY PER WEEK OPERATING FACILITY. IT WILL BE NECESSARY TO
INCLUDING BUT NOT LIMITED TO, DAMAGE CAUSED BY IMPACT, WATER, DEBRIS AND DUST.
G.1 CONTRACTOR SHALL PROTECT FAA EQUIPMENT, BOTH INSIDE AND OUTSIDE BUILDING, FROM DAMAGE, G. EQUIPMENT PROTECTION.
OF PERFORMANCE OF THE WORK.
COORDINATED AND APPROVED IN WRITING BY COR WITH A MINIMUM OF 10 WORKING DAYS IN ADVANCE
F.2 NOISY DEMOLITION (INSIDE OR OUTSIDE) AND OFF-HOURS CONSTRUCTION ACTIVITIES SHALL BE SCHEDULED, DEMOLITION AND CONSTRUCTION NOISE SHALL BE MINIMIZED BETWEEN 6:00 AM TO 11:00 PM.
F.1 CONTRACTOR SHALL NOT INTERFERE WITH AIR TRAFFIC CONTROL FUNCTION OF THIS FACILITY.
F. DEMOLITION AND CONSTRUCTION HOURS.
E.2 CONTRACTOR SHALL NOT USE FAA DUMPSTERS.
SHALL BE REMOVED BY CONTRACTOR DAILY.
SHALL BE KEPT CLEAN AND FREE OF EXCESS DEBRIS AND DUST DURING CONSTRUCTION. DEBRIS
LOCATIONS TO BE DETERMINED BY CONTRACTING OFFICER REPRESENTATIVE (COR). AREAS AROUND DUMPSTERS
E.1 DUMPSTERS FOR DISPOSAL OF CONSTRUCTION DEBRIS SHALL BE PROVIDED BY CONTRACTOR. DUMPSTER
E. CONSTRUCTION DEBRIS.
BURIED CABLES (UNDERGROUND UTILITIES) MAY RUN THROUGH STAGING AREA AND ELSEWHERE.
CONTRACTOR SHALL DO NO DIGGING WITHOUT PRIOR PERMISSION FROM COR.
STAGING AREA. MATERIALS SHALL BE NEATLY STORED AND PROTECTED.
D.1 STORAGE OF CONSTRUCTION MATERIALS AND TRAILERS ON SITE SHALL BE LIMITED TO THE CONSTRUCTION
D. CONSTRUCTION MATERIAL STORAGE.
PARKING
VISITOR
ZMA-D-1404046-A101.dgn 5/4/2016 2:19:20 PM
F
IL
E
:0
:4
A
M D a n ie l D o b y
H H
8 1234567
G
F
E
D
C
B
A
G
F
E
D
C
B
A
REV DESCRIPTION JCN
DATE
REDLINE
DATE
APPROVED
APVD
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
SUBMITTED BY APPROVED BY
JCN
DRAWN
CHECKED
REV
ISSUED BY DATE
DRAWING NO
DESIGNED
REVIEWED BY
SCALES SHOWN FOR 22" X 34" SHEET. ADJUST SCALES FOR OTHER SIZES.
ATLANTA NAS
EASTERN SERVICE AREA ATLANTA, GA
ENGINEERING
JD
JD
JOE DOBY, RA
FOR OFFICIAL USE ONLY
PUBLIC AVAILABILITY TO BE DETERMINED UNDER 5 USC 552
CONTROL WING
AUTOMATION WING
A D
M
IN
IS
T R
A T
IO
G
LEGEND
- SCUPPERS
- VENTS
030’ 30’ 60’
SCALE: 1" = 30’
68’-0"
POWER SERVICEA
C D
B
E
G
GENERAL NOTES
- DRAIN
- DRAINAGE DIRECTION
2. PRIOR TO REMOVING EXISTING ROOFING SYSTEM THE CONTRACTOR SHALL
CONDITION OF THE METAL DECK, PUDDLE WELDS AND TEK SCREWS FOR
DECK ATTACHMENT. AFTER THE INSPECTION THE PROFESSIONAL ENGINEER
SHALL MAKE RECOMMENDATIONS FOR REPAIR OR ADDITIONAL REINFORCEMENT
IF REQUIRED, TO COMPLY WITH THE LATEST FLORIDA BUILDING CODE
(FBC). CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR THE CORRUGATED
STEEL DECK AND ATTACHMENT AND A REPAIR COST ESTIMATE ON A SQUARE
FOOT BASIS.
3. PROTECT ROOF MOUNTED EQUIPMENT. COORDINATE THE WORK AND ACCESS
MATERIALS CONTAIN CHRYSOTILE ASBESTOS. THE ROOF MATERIALS WERE IN GOOD
CONDITION AT THE TIME OF INSPECTION. ALL APPLICABLE LOCAL, STATE AND
FEDERAL REGULATIONS CONCERNING ASBESTOS REMOVAL MUST BE OBSERVED.
N
A102
CAMPUS ROOF DEMOLITION PLAN
ROOF "B" 4,080
ROOF "G" 150
TO ROOF WITH COR.
ZMA-D-1404046-
DESIGN ENGINEER, ENROUTE
ENROUTE
MD/JS
1404046
(ZMA ARTCC)
A102
MANAGER, ENROUTE
JOE SCHMITT
ARCHITECTURAL
CAMPUS DEMOLITION PLAN & NOTES
MIAMI FLORIDA
AUTOMATION WING STAIRS
POWER SERVICES BLDG
HIRE A FLORIDA REGISTERED STRUCTURAL ENGINEER TO INSPECT THE EXISTING
5. CONTRACTOR SHALL VERIFY EXISTING DIMENSIONS IN FIELD PRIOR
TO BEGINING WORK.
LOW SLOPED METAL DECK
PROTECTION SYSTEM IN AREAS OF WORK.
PER NOTE 2 THIS SHEET. TEMPORARILY DISCONNECT LIGHTNING
FLASHINGS, ROOF DRAINS AND COPINGS. EXAMINE ROOF DECK
FLAT INSULATION, MEMBRANE, SCUPPERS, PARAPET & WALL
UNDERLAYMENT BOARDS, PROTECTION BOARDS, TAPERED AND
REMOVE EXISTING ROOFING SYSTEM INCLUDING CRICKETS,
POWER SERVICES BUILDING AND
AUTOMATION WING PARTIAL ROOF REPLACE
3/31/2016
1. REPLACE EXISTING LIGHTNING PROTECTION SYSTEM ON ROOF "B" AS WORK
PROGRESSES, KEEPING SYSTEM IN OPERATION,
4. ROOF DRAINS ON ROOF ’B’ WILL BE REPLACED; COORDINATE DEMOLITION WITH COR.
PAGE OF 10
FOOTAGE
SQUARE
TYPE
DECK
ROOF
- REMOVE EXISTING ROOF SYSTEM
7. ADDITIONAL REQUIREMENTS ARE LISTED IN THE SPECIFICATIONS.
6. PER ASBESTOS SURVEY BY ?????, DATED MAY 2016, THE COMPOSITE ROOFING
LOW SLOPED CONCRETE SLAB DECK
16’-8"
NOTE 2 THIS SHEET.
AND EDGE FLASHING. EXAMINE ROOF DECK PER
INSULATION, MEMBRANE, SCUPPERS, WALL FLASHING
CRICKETS, UNDERLAYMENT AND PROTECTION BOARDS,
REMOVE EXISTING ROOFING SYSTEM INCLUDING
ZMA-D-1404046-A102.dgn 5/12/2016 8:09:41 AM
F
IL
E
:4
:1
D a n ie l D o b y
H
G
F
E
D
C
B
A
8 1234567
DRAWN
CHECKED
REVDRAWING NO
ENGINEERING
JD
C
B
A
REV DESCRIPTION JCN
DATE
REDLINE
DATE
APPROVED
APVD
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
SUBMITTED BY APPROVED BY
JCNISSUED BY DATEDESIGNED
REVIEWED BY
ATLANTA NAS
EASTERN SERVICE AREA ATLANTA, GA
JD
JOE DOBY, RA
FOR OFFICIAL USE ONLY
PUBLIC AVAILABILITY TO BE DETERMINED UNDER 5 USC 552
H
G
F
E
D
ENROUTE
MD/JS
DESIGN ENGINEER, ENROUTE
8 1234567
F
IL
E
:4
:1
D a n ie l D o b y
H
G
F
E
D
C
B
A
8 1234567
DRAWN
CHECKED
REVDRAWING NO
ENGINEERING
JD
C
B
A
REV DESCRIPTION JCN
DATE
REDLINE
DATE
APPROVED
APVD
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
SUBMITTED BY APPROVED BY
JCNISSUED BY DATEDESIGNED
REVIEWED BY
SCALES SHOWN FOR 22" X 34" SHEET. ADJUST SCALES FOR OTHER SIZES.
ATLANTA NAS
EASTERN SERVICE AREA ATLANTA, GA
JD
H
G
F
E
D
ENROUTE
MD/JS
DESIGN ENGINEER, ENROUTE
010’ 10’ 20’
SCALE: 1" = 10’
NOTES
- ROOF DRAIN
LEGEND
N
MANAGER, ENROUTE
JOE SCHMITT
A103
A103ZMA-D-1404046-
1404046
MIAMI (ZMA ARTCC) FLORIDA
ARCHITECTURAL
A 37’- 0"
END OF PANEL
TOP OF EXIST MET DECK (LP)
TOP OF EXISTING
FACE OF EXISTING
PLYWOOD
TOP OF EXISTING METAL DECK (LP) TOP OF EXISTING METAL DECK (HPT)
BOTTOM OF WALL FLASHING
(CONSTANT)
M I
N
NEW OVERFLOW
SCUPPER
1’-0"
5’- 6"
TOP OF EXISTING
FACE OF EXISTING
PLYWOOD
FACE OF EXISTING PLYWOOD
BOTTOM OF SIDING
(CONSTANT)
CRICKET LINE
ALONG WALL
2 3 1 C E F
31’-0"
SLOPE DN SLOPE DN
4"
EXISTING ROOF EL
-FACE OF EXIST
MASONRY
HP OF
CRICKET
TOP OF EXIST METAL
5 1/2" 23’- 4 1/2" 31’- 1 1/2" 5 1/2" 5 1/2"
PARAPET ELEVATION - LOOKING WEST
PARAPET ELEVATION - LOOKING NORTH
8 0 8 16
1/8" = 1’-0"
8 0 8 16
1/8" = 1’-0"
F
D
B
A
1’2’3’4’6’ 5’7’
C’
D’
F
D
C’
D’
F
D
C’
D’
F
D
A’
LOW ROOF
GIRT LINE
2 1/2" EXP JT
LADDER &
HIGH ROOF
E
C
37’-0" 31’-0"
SL
OP
E
(T
YP
SLOPE DOWN
SLOPE DOWN
R I
D G
E
WALKWAYS TO SERVICE
EXISTING
GENERATOR
BUILDING
RUNGS SHALL BE CLEAR OF
EXIST ROOF VENT
TO REMAIN(TYP 4 PLACES)
A
B C
D
E
A103
C D
A103
PAGE OF 10
3/31/2016
ROOF DRAINS
A103
NO ROOF WORK REQUIRED THIS AREA
LOW
PSB ROOF PLAN
MID ROOF
PARTIAL ROOF PLAN
AUTO WING STAIRS
LOW
G
A502
A
A502
B
ROOF
PSB & PARTIAL AUTO WING ROOF PLANS
8 0 8 16
1/8" = 1’-0"
E
A103
PARAPET ELEVATION - LOOKING EAST
(LOOKING SOUTH - OPPOSITE HAND)
NEW WALL FLASHING
OVER NEW PLYWOOD (TYP)
ROOF
F D B A
ROOF LINE
SECOND
FLOOR
TOP OF EXIST METAL
HP OF
CRICKET
PREFORMED METAL SIDING TO REMAIN (TYP)
CRICKET LINE
ALONG WALL
RD
- ROOF VENTRV
RV
RDRD
RD RD
A501
C
A501
C
A501
D
2. CONTRACTOR TO REMOVE EXISTING ROOF SYSTEMS ON B AND G
ROOF LADDERS AND
WALL FLASHING BY 7" MIN
NEW 4" ROOF DRAIN
SEE DETAIL A/A501
RL - ROOF LADDER
FLASHING AND METAL COPING.
SYSTEM INCLUDING VERTICAL WALL
- REPLACE EXISTING ROOF MEMBRANE
ONLY. REPLACE COPING, WALL FLASHING, ROOF DRAINS
AND SCUPPERS ON THESE TWO ROOFS.
NEW CRICKET (TYPICAL)
NEW
NEW OVERFLOW
SCUPPER SEE F/A501 (TYP OF 4)
NEW WALL FLASHING OVER NEW PLYWOOD
NEW WALL FLASHING OVER NEW PLYWOOD
E
A103
C
A103
C
A103
(OPP. HAND)
D
A103
A502
E
A502
D
A502
D
(@ EXP. JT.)
(@ EXP. JT.)
(@ EXP. JT.)
A502
E
A502
D
A502
D
A501
C
16’-0"
010’ 10’ 20’
SCALE: 1" = 10’
POWER SERVICES BUILDING AND
AUTOMATION WING PARTIAL ROOF REPLACE
ON B ROOF ONLY. SEE E102.
NOTE 4
PLATFORM
1. ROOF B IS LOWEST ROOF ON PSB.
NO ROOF WORK REQUIRED THIS AREA
REQUIRED THIS AREA
NO ROOF WORK
R E
Q U
IR
IS
E A
F
3. CONTRACTOR TO INSTALL NEW LIGHTNING PROTECTION SYSTEM
SEE DETAILS THIS SHEET
NEW LADDERS
NEW LADDER SEE DETAILS THIS SHEET
NEW
NEW LADDER AND
PLATFORM WITH NEW BRACKETS.
A103 N.T.S.
I
N
X
ROOF SURFACE
COPING
TOP OF
2’-6"
1’-6"
ELEVATION AT ROOF A
PROFILE
AT ROOF C & D
PROFILE
ELEV./PROFILES
TYPICAL LADDER
WALKWAY
LADDER
TOP OF
Y
P
3’-6" MIN.
7" MIN.
MIN.
7"
7" MIN.
MIN. DIM.
FOR 7" CLEAR
AS NEEDED
FIELD MEASURE
IRON BRACES
2 X 2 ANGLE
GRATING
WALKWAY
1 1/2"
- BEAR ON WALKPAD
ADJUSTED FOR HEIGHT
SLOTTED ANGLE SUPPORT
TO REMAIN
EXISTING ANCHORS
RL
RL
RL
4. CONTRACTOR TO REPLACE LADDERS (SEE SPEC).
DECK (LP) EL 15’-0 1/2" +
18’-9 1/4"+
DECK (LP) EL 15’-0 1/2" +
PARAPET EL 21’-6"
PARAPET EL 21’-6"
EL 15’-0 1/2" + EL 15’-7 1/2" + EL 15’-0 1/2" +
ZMA-D-1404046-A103.dgn 5/12/2016 12:43:13 PM
F
IL
E
:1
:4
D a n ie l D o b y
H
G
F
E
D
C
B
A
8 1234567
DRAWN
CHECKED
REVDRAWING NO
ENGINEERING
JD
C
B
A
REV DESCRIPTION JCN
DATE
REDLINE
DATE
APPROVED
APVD
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
SUBMITTED BY APPROVED BY
JCNISSUED BY DATEDESIGNED
REVIEWED BY
ATLANTA NAS
EASTERN SERVICE AREA ATLANTA, GA
JD
JOE DOBY, RA
FOR OFFICIAL USE ONLY
PUBLIC AVAILABILITY TO BE DETERMINED UNDER 5 USC 552
H
G
F
E
D
ENROUTE
MD/JS
DESIGN ENGINEER, ENROUTE
8 1234567
F
IL
E
:1
D a n ie l D o b y
H
G
F
E
D
C
B
A
8 1234567
DRAWN
CHECKED
REVDRAWING NO
ENGINEERING
JD
C
B
A
REV DESCRIPTION JCN
DATE
REDLINE
DATE
APPROVED
APVD
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
SUBMITTED BY APPROVED BY
JCNISSUED BY DATEDESIGNED
REVIEWED BY
ATLANTA NAS
EASTERN SERVICE AREA ATLANTA, GA
JD
H
G
F
E
D
ENROUTE
MD/JS
DESIGN ENGINEER, ENROUTE
PAGE OF 106
3/31/2016
MANAGER, ENROUTE
JOE SCHMITT
1/2" DENS DECK
TPO ROOF MEMBRANE
POLY ISO RIGID INSULATION
5/8" FIREGUARD TYPE X DENS DECK
TYPICAL ROOF ASSEMBLY DETAIL
(EXISTING) METAL DECK
COVER BOARD AND THERMAL INSULATION
THERMOPLASTIC ROOF MEMBRANE
DRAIN STRAINER
ROOF DECK
CLAMPING RING
DECK CLAMP
DRAIN BOWL
TAPERED INSULATION
ROOF DETAIL ROOF DRAIN
1. MEMBRANE SEAMS SHOULD NOT INTERSECT DRAIN CLAMPING RING.
BOWL FLANGE AND ROOF MEMBRANE
INSTALL COMPATIBLE SEALANT BETWEEN DRAIN
EXTEND APPROX. 1’’[25 mm] PAST CLAMPING RING
ROUND CUT IN THERMOPLASTIC MEMBRANE;
THAN DRAINPIPE DIAMETER
HOLE IN MEMBRANE SHOULD BE LARGER
NOTE:
A501ZMA-D-1404046-
1404046
ARCHITECTURAL
ROOFING DETAILS
FLORIDA(ZMA ARTCC)MIAMI
A501
A501
TPO MEMBRANE
HEAT WELDED LAP
PLATES & SCREWS 4 PER STACK
PREMOLDED BOOT
STAINLESS STEEL CLAMP
CAULKING
VENT STACK
WATER BLOCK
PREMOLDED PENETRATION FLASHING
SHOULD BE USED WHENEVER POSSIBLE.
IN SMALL AND LARGE SIZES AND
PREMOLDED BOOTS ARE AVAILABLE
IT MUST BE PULLED OVER VENT PIPE
DO NOT CUT PREMOLDED BOOT.
NOTE
(1/2" DENS DECK)
PROTECTION BOARD
DENS DECK
5/8" FIREGUARD TYPE "X"
RIGID INSULATION
ROOF DECK
AT ROOF PENETRATIONS.
NOTE: PROVIDE U.L. APPROVED FIRE AND SMOKE SEALANT
A501
A
C A501
METAL SIDING
PREFORMED
SEE STRUCT DWG
CONT BENT L
1’-6"
7"
5"1
RIGID INSUL
M I
N 3"
MIN
TOP OF STEEL
METAL DECK
3"
CONT CLEAT
CLOSURE (TYP)
SIDING PROFILE
MEMBRANE
ROOFING
SINGLE PLY
METAL CAP
PREFINISHED
JOIST
STRUCT STEEL
STRUCT BEAM
OF WOOD NAILER
EXTEND MEMBRANE OVER TOP
SEE NOTE BELOW FOR REQD FASTENERS
�" EXTERIOR GRADE PLYWOOD
SHEET METAL SCREWS AT 12" OC AT EDGES AND FIELD
FASTEN PLYWOOD TO LINER PANEL WITH CSK PAN HEAD
METAL SCREWS @ 12" OC EACH FACE
FASTEN TO LINER PANEL WITH SHEET
CONT 18 GA SHEET METAL CLOSURE
#4 POINT AT 24" OC
WITH WOOD TO METAL SCREWS:
2x6 SHAPED WOOD NAILER
POINT
ABOVE ROOF LOW
SCUPPER. SET 2"
6" WIDE GALV MET
SLOPE
ASSEMBLY
ROOF DRAIN
NEOPRENE WASHERS
FASTENERS @ 24" OC THRU
NOTE
BELOW BLOCKING
1’’ [25 mm] MIN.
WOOD NAILER
FLASHING MEMBRANE
THERMOPLASTIC ROOF MEMBRANE
COVER BOARD AND THERMAL INSULATION
ROOF DECK
SHEET METAL PARAPET CAP
CONTINUOUS SHIM
GASKETED FASTENERS
SEALANT (IF REQUIRED FOR THE SPECIFIC SYSTEM)
FASTENERS APPROX. 12’’[300 mm] O.C.
BELOW NAILER AND SECURE
EXTEND MEMBRANE TO
SECUREMENT OPTIONS FOR SHEET METAL.
2. REFER TO THE SHEET METAL SECTION OF THE METAL ROOFING MANUAL FOR JOINERY AND
EXPANSION.
1. THIS DETAIL SHOULD BE USED ONLY WHERE THE DECK IS SUPPORTED BY THE WALL
CONTINUOUS CLEAT
SEAM PLATES AND FASTENERS
NOTES:
NOTE
1. ROOF ASSEMBLY SHALL BE MINIMUM R-30
SIDING PROFILE
CLOSURE
EXISTING
ROOF DECK
EXISTING
CONT CLIP WITH
FASTENERS AT
12" OC
EXISTING WOOD NAILERS
EXISTING METAL DECK
V A
R I
E S
N
TOP OF BASE FLASHING
N
SIDING PROFILE
CLOSURE
NOTES
FASTENERS AT
24" OC
TOP OF PARAPET
PREFINISHED
METAL CAP
METAL DRIP
FASTENERS
RETAIN EXISTING FLASHING EXISTING ROOFING
1. REMOVE EXISTING LIGHTNING
PROTECTION SYSTEM AND
COPING (INCLUDING WOOD
NAILER) AT TOP OF PARAPET
PROTECTION SYSTEM PER
SLOPE
2. VERIFY THICKNESS OF EXIST
WALL PRIOR TO FABRICATION
AND INSTALLATION OF SHEET
METAL CAP AND SHAPING OF
WOOD NAILER
1 1/4"1 1/2"
D A501
A501
B TYPICAL PARAPET FLASHING
SCALE: N.T.S.
SCALE: N.T.S.
PARAPET SECTION
PARAPET DETAIL
SCALE: N.T.S.
N.T.S.
N.T.S.
SCALE: N.T.S.
A501
F
SCALE: N.T.S.
ROOF DRAIN & SCUPPER
METAL COPING
NEW PREFINISHED 22 GA
METAL CAP
NEW PREFINISHED
METAL FLASHING
NEW PREFINISHED SHEET
FASTENERS AT 12" OC
NEW CONT CLEAT W/
SUBSTRATE
FLASHING OVER NEW PLYWOOD
INSTALL NEW VERTICAL WALL
REMOVE EXISTING ROOFING &
NEW 22 GA GALV SHEET
BACKING
NEW PLYWOOD
CONSTANT
FLASHING SHALL BE
BOTTOM OF COUNTER
TO REMAIN
CONSTRUCTION
EXISTING PARAPET
EXISTING TO REMAIN
METAL SIDING
PREFINISHED
REMOVE EXISTING
NAILER (AS REQUIRED)
FOR SECURING WOOD
GALV SHT MTL CLOSURE
PROVIDE NEW CONT 18 GA
AT 12" OC
W/ FASTENERS
NEW CONT CLEAT
MET SCREWS:#4 POINT AT 24"OC
TREATED) WD NAILER W/ WD TO
NEW 2x CONT (SHAPED &
POWER SERVICES BUILDING AND
AUTOMATION WING PARTIAL ROOF REPLACE
NEW RIGID INSULATION
NEW BASE FLASHING MEMBRANE
NEW PERIMETER METAL BAR AND
NEW SINGLE PLY ROOF MEMBRANE
SUBMITTED TO COR FOR REVIEW PRIOR TO START OF WORK.
REPLACED BY MANUFACTURER’S WARRANTY APPROVED DETAILS AND
SHOWING EXTENT AND SCOPE ONLY; THESE DETAILS ARE TO BE
EXISTING PROFILES. DETAILS 1, 2, A & B ARE NRCA DETAILS
DETAILS C, D & F ARE SITE SPECIFIC SHOWING CONFIGURATION OF
NOTE:
NEW TAPERED CRICKET SEE PLAN
SPECIFICATIONS
NEW PLYWOOD SHEATHING
WALL FLASHING OVER
METAL SIDING & INSTALL NEW
REMOVE EXISTING PREFINISHED
WALL
3. REPLACE LIGHTNING
ELECTRICAL SHEETS AND
CL
EL 21’-6"
EL 32’-6"
TOP OF PARAPET
EL 29’-10"
ZMA-D-1404046-A501.dgn 5/4/2016 2:12:47 PM
F
IL
E
:1
D a n ie l D o b y
H
G
F
E
D
C
B
A
8 1234567
DRAWN
CHECKED
REVDRAWING NO
ENGINEERING
JD
C
B
A
REV DESCRIPTION JCN
DATE
REDLINE
DATE
APPROVED
APVD
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
SUBMITTED BY APPROVED BY
JCNISSUED BY DATEDESIGNED
REVIEWED BY
ATLANTA NAS
EASTERN SERVICE AREA ATLANTA, GA
JD
JOE DOBY, RA
FOR OFFICIAL USE ONLY
H
G
F
E
D
ENROUTE
MD/JS
DESIGN ENGINEER, ENROUTE
8 1234567
F
IL
E
:1
D a n ie l D o b y
H
G
F
E
D
C
B
A
8 1234567
DRAWN
CHECKED
REVDRAWING NO
ENGINEERING
JD
C
B
A
REV DESCRIPTION JCN
DATE
REDLINE
DATE
APPROVED
APVD
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
SUBMITTED BY APPROVED BY
JCNISSUED BY DATEDESIGNED
REVIEWED BY
SCALES SHOWN FOR 22" X 34" SHEET. ADJUST SCALES FOR OTHER SIZES.
ATLANTA NAS
EASTERN SERVICE AREA ATLANTA, GA
JD
FOR OFFICIAL USE ONLY
PUBLIC AVAILABILITY TO BE DETERMINED UNDER 5 USC 552
H
G
F
E
D
ENROUTE
MD/JS
DESIGN ENGINEER, ENROUTE
PAGE OF 107
3/31/2016
MANAGER, ENROUTE
JOE SCHMITT
THERMOPLASTIC ROOF MEMBRANE
ROOF DECK
MEMBRANE CAP
PLUMBING VENT STACK
PLUMBING VENT ROOF DETAIL
FLASHING MEMBRANE(8’’ [200 mm] MIN. HEIGHT)
AS REQUIRED FOR SPECIFIC SYSTEM
BASE MEMBRANE ATTACHMENT
COVER BOARD AND THERMAL INSULATION
CURBS, AND OTHER PROJECTIONS TO FACILITATE PROPER FLASHING
OF 12 INCHES [300 mm] OF CLEARANCE ON ALL SIDES FROM WALLS,
1. VENT STACKS AND OTHER PIPES SHOULD HAVE A MINIMUM
NOTE:
SEALANT (IF REQUIRED FOR THE SPECIFIC SYSTEM)
NOT TO SCALE
A502ZMA-D-1404046-
A502
INSULATION
THERMAL AND
COVERBOARD
MEMBRANEROOF
THERMOPLASTIC
SYSTEM)
THE SPECIFIC
REQUIRED FOR
SEALANT (IF
MEMBRANE
FLASHING
CONTINUOUS CLEAT
NAILERS
WOOD
B E
L
B
O C
K
IN
G
WOOD NAILERS
TO FASTENED
WOOD CANT
FASCIA CAP
SHEET METAL
FASTENERS
GASKETED
METAL FLASHING (FASCIA CAP)
RAISED PERIMETER EDGE WITH
ROOF DECK
FLASHING
MEMBRANE
APPROPRIATE SEALANT
(E.G., POLYURETHANE)
DRAW BAND
COMPATIBLE SEALANT
MIN. FLANGE
NON-SHRINK
GROUT
COVERBOARD AND
THERMAL INSULATION
ROOF DECK
THERMOPLASTIC
ROOF MEMBRANE
[100 MM] MIN. HEIGHT)
PITCH PAN (4’’
COATED METAL
METAL OR MEMBRANE
SOLDERED SHEET
WEATHERPROOF
PENETRATION POCKET
COLLAR OVERLAPPING
SHEET METAL RAIN
SYSTEM)
THE SPECIFIC
REQUIRED FOR
SEALANT (IF
SEALANT
POURABLE
SPECIFIC SYSTEM
REQUIRED FOR
SECUREMENT AS
BASE MEMBRANE
FASTENERS
SEAM PLATES AND
FASTENED
AT CORNERS
CLEARANCE
APPROX. 1/4’’ [6 MM]
4’’ [100 MM]
SURFACE MOUNTED COUNTERFLASHING
CONCRETE FASTENERS
INSTALL COMPATIBLE SEALANT BEHIND MEMBRANE
THERMOPLASTIC ROOF MEMBRANE
COVER BOARD AND THERMAL INSULATION
ROOF DECK
SEALANT (IF REQUIRED FOR THE SPECIFIC SYSTEM)
FLASHING MEMBRANE (8’’ [200 mm] MIN. HEIGHT)
SHEET METAL COUNTERFLASHING
NOTES:
FOR JOINERY AND SECUREMENT OPTIONS FOR SHEET METAL.
2. REFER TO THE SHEET METAL SECTION OF THE METAL ROOFING MANUAL
1. THIS DETAIL SHOULD BE USED ONLY WHERE THE DECK IS SUPPORTED BY THE WALL.
AND TOOL TO FACILITATE WATER RUN-OF
INSTALL APPROPRIATE SEALANT (E.G., POLYURETHANE)
SEALANT OR TAPE TO SPAN IRREGULARITIES
OPTIONAL: INSTALL COMPRESSIBLE ELASTOMERIC
FASTENERS APPROX. 12’’ [300 mm] O.C.
TERMINATION BAR FASTENED WITH APPROPRIATE
FOR ALTERNATE PERIMETER SECUREMENT OPTIONS
SEAM PLATES AND FASTENERS
7’1
EXTRA WIDE SUBGIRT
2’-5"
7"
EXP JT
7’1
2’-5"
T A
P E
R
C
I
C K
E T
TREATED WD NAILERS.
FASTEN BOTT NAILER
TO METAL DECK WITH
WD TO MET SCREWS:
#4 POINT AT 24" OC
TOP OF PARAPET
TOS EL VARIES
EXP JT
EXISTING
BENT PLATE
EXISTING
MTL DECK
2 1/2 "
2 1/2"
10 1/4"
EXIST EXT 1 1/2" MTL SIDING
A
A502 B
A502
C
A502 NOT TO SCALE
PENETRATION POCKET
D
A502
E
A502
1404046
ARCHITECTURAL
ROOF DETAILS
MIAMI (ZMA ARTCC) FLORIDA
TO REMAIN
EXISTING CONSTRUCTION
PARAPET EL 21’-6"
EXISTING TOP OF
SHEET METAL CLOSURE
EXIST 18 GA GALV
GIRT
EXISTING
W/ INSULATION
EXISTING LINER PANEL
METAL SIDING TO REMAIN
EXISTING PREFORMED
GALV DRIP
EXISTING 18 GA
EXP JT TO REMAIN
EXISTING PREFABRICATED
NEW COPING
TO REMAIN
CONSTRUCTION
EXISTING
EXP JT TO REMAIN
EXISTING PREFABRICATED
NEW CRICKET
NEW METAL COPING
EXIST. STEEL DECK
ON DENS. DECK OVER
NEW RIGID INSULATION
SHEATHING
NEW PLYWOOD
WALL FLASHING
NEW VERTICAL
POWER SERVICES BUILDING AND
AUTOMATION PARTIAL ROOF REPLACE
NOT TO SCALE - AT ROOF ’G’ ONLY
NOT TO SCALE - AT ROOF ’G’ ONLY
DETAIL AT EXPANSION JOINT
DETAIL AT EXP. JT.
AND SUBMITTED TO COR FOR REVIEW PRIOR TO START OF WORK.
REPLACED BY MANUFACTURER’S WARRANTY APPROVED DETAILS
SHOWING EXTENT AND SCOPE ONLY; THESE DETAILS ARE TO BE
EXISTING PROFILES. DETAILS 1, A, B & C ARE NRCA DETAILS
DETAILS D & E ARE SITE SPECIFIC SHOWING CONFIGURATION OF
NOTE:
NOT TO SCALE - ROOF ’B’ ONLY
NOT TO SCALE - ROOF ’B’ ONLY
EL 21’-6"
EL 17’-1"
ELEV 21’-6"
ELEV 22’-0"
ZMA-D-1404046-A502.dgn 5/4/2016 2:13:54 PM
E
A
B
REQUIRED THIS AREA
PROTECTION WORK
NO LIGHTNING
R E
Q U
IR
E A
P R
O T
E C
T
IG
H T
N
3’4’6’ 5’7’ 1
C’
F
D
C’
F
D
C’
F
D
B
A
D
F
2 3
LOW ROOF
RD
RD
HIGH ROOF
MID ROOF
RD
REQUIRED IN THIS AREA
PROTECTION WORK
NO LIGHTNING
THIS AREA
WORK REQUIRED IN
PROTECTION
NO LIGHTNING
37’-0" 31’-0"
E D
M
IS
S
U
R
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
ACTIVE
FLMIAMI
LEGEND:
GENERAL NOTES:
SHEET NOTES:
N
08’ 8’
SCALE: 1/8" = 1’-0"
16’
(LOW ROOF)
ARTCC
MIAMI CENTER
Z
A
D
E .d g n
ENGINEERING SERVICES
ENROUTE/FSS
PARTIAL ROOF REPLACEMENT
POWER SERVICE BUILDING
DM
DM
PROJECT ENGINEER MGR: ENROUTE/FSS ENGR CTR
02/09/2016 1404046
THIS DRAWING PRODUCED ON ASO REGION MICROSTATION SYSTEM
ATO - TECHNICAL OPERATIONS EASTERN SERVICE AREA
ZMA-D-1404046-E101
F
IE
V
IS
IO
N
SYSTEM TO REMAIN
LIGHTNING PROTECTION
EXISTING ROOF "A"
STEEL LADDER
RD
RDRD
RD
FIELD VERIFIED.
ON THE ROOF ARE APPROXIMATE. EXACT LOCATIONS SHALL BE
LOCATION OF LIGHTNING PROTECTION SYSTEM COMPONENTS 2.
GOVERNMENT.
CONDITIONS TO PRODUCE AND ACCEPTABLE PRODUCT FOR THE
CONFIRM ALL INFORMATION PROVIDED HERE WITH EXISTING SITE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY AND
ENCOUNTERED DURING THE CONSTRUCTION PROCESS. IT IS THE
INTENDED TO SHOW ALL POSSIBLE CONDITIONS TO BE
THESE DRAWINGS ARE SCHEMATIC IN NATURE AND ARE NOT 1.
TO ACCOMODATE ROOF "B" REPLACEMENT WORK.
FLASHING TO REMAIN. DISCONNECT AND REINSTALL AS REQUIRED
EXISTING ROOF "A" MAIN CONDUCTOR RUNNING ON ROOF 4
INDICATED ON DRAWING E102.
CONNECTOR FOR NEW INSTALLATION ON ROOF "B" AS
CONDUCTOR ON ROOF "A" TO REMAIN. PROVIDE NEW SPLICE
REMOVE BI-METAL SPLICE CONNECTION TO MAIN LIGHTNING 3
DRAWING E102.
CONDUCTORS FOR FINAL INSTALLATION, AS INDICATED ON
REPLACEMENT WORK. PROVIDE NEW CONNECTORS AND
TEMPORARILY AS REQUIRED TO ACCOMODATE ROOF
EXISTING TO REMAIN DOWN LEAD CONDUCTORS. DISCONNECT 2
PROTECTION SYSTEM AS INDICATED ON DRAWING E102.
ENTIRETY FOR ROOF "B". PROVIDE NEW LIGHTNING
REMOVE EXISTING LIGHTNING PROTECTION SYSTEM IN ITS 1
90% DESIGN
E101 SCALE: 1/8" = 1’-0"
PARTIAL POWER SERVICE BUILDING ROOF - LIGHTNING PROTECTION DEMOLITION PLAN
LIGHTNING PROTECTION DEMOLITION PLAN
STEEL LADDER
ELEMENTS AND/OR EQUIPMENT
BONDING CONNECTION TO METAL STRUCTURE, BUILDING
CLASS II AIR TERMINAL WITH BASE
COPPER CONDUCTOR TO BUILDING COUNTERPOISE.
DOWN LEAD CONDUCTOR TO LOWER ROOF OR TO EXISTING
MAIN LIGHTNING PROTECTION CABLE, CLASS II
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
REV DESCRIPTION JCN
DATE
REDLINE
APVD
SUBMITTED BY APPROVED BY
JCN
DRAWN
CHECKED
REV
ISSUED BY
H
G
F
E
D
C
B
A
H
G
F
E
D
C
B
A
8 1234567
8 1234567
DATE
DRAWING NO
DESIGNED
REVIEWED BY
:1
D a n ie l D o b y
DATE
APPROVED
Z M
A
D
E .d g n
E
A
B
REQUIRED THIS AREA
PROTECTION WORK
NO LIGHTNING
R E
Q U
IR
E A
P R
O T
E C
T
IG
H T
N
3’4’6’ 5’7’ 1
C’
F
D
C’
F
D
C’
F
D
B
A
D
F
2 3
LOW ROOF
RD
RD
HIGH ROOF
MID ROOF
RD
REQUIRED IN THIS AREA
PROTECTION WORK
NO LIGHTNING
THIS AREA
WORK REQUIRED IN
PROTECTION
NO LIGHTNING
37’-0" 31’-0"
E D
M
IS
S
U
R
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
MIAMI
LEGEND:
N
08’ 8’
SCALE: 1/8" = 1’-0"
16’
(LOW ROOF)
A
D
E .d g n
SHEET NOTES:
ELEMENTS AND/OR EQUIPMENT.
BONDING CONNECTION TO METAL STRUCTURE, BUILDING
SOLID ALUMINUM AIR TERMINAL WITH BASE, CLASS II, BLUNT TIP.
BI-METAL CONNECTOR AS REQUIRED.
COPPER CONDUCTOR TO BUILDING COUNTERPOISE. PROVIDE
DOWN LEAD CONDUCTOR TO LOWER ROOF OR TO EXISTING
REQUIREMENTS). FASTENING TO BUILDING EVERY 3 FEET MAX.
OF 13 GAUGE WIRE, 98 LBS. PER 1000 FEET (MIN.
MAIN LIGHTNING CONDUCTOR, CLASS II - ALUMINUM, 37 STRANDS
CONDUCTOR (TYPICAL)
SUPPORTS OF EXPOSED
3’-0" MAXIMUM BETWEEN
ADHESIVE CABLE HOLDERS 6
E501
VENT PIPE
E501
(TYP.)
E501
E501
(TYP.)
(TYP.)
(TYP.)
90% DESIGN
STEEL LADDER
ROOF "D" TO REMAIN
PROTECTION SYSTEM ON
EXISTING LIGHTNING
ROOF "A" TO REMAIN
PROTECTION SYSTEM ON
EXISTING LIGHTNING
RD
RD
RDRD
RD
E D
M
IS
S
U
R
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
FLMIAMI
DM
DM 02/09/2016 1404046
ENGINEERING SERVICES
ENROUTE/FSS
PARTIAL ROOF REPLACEMENT
POWER SERVICE BUILDING
PROJECT ENGINEER MGR: ENROUTE/FSS ENGR CTR
A
D
E .d g n
THIS DRAWING PRODUCED ON ASO REGION MICROSTATION SYSTEM
ATO - TECHNICAL OPERATIONS EASTERN SERVICE AREA
ZMA-D-1404046-E102
F
IE
V
IS
IO
N
ENGINEERING SERVICES
ENROUTE/FSS
PARTIAL ROOF REPLACEMENT
POWER SERVICE BUILDING
DM
DM
PROJECT ENGINEER MGR: ENROUTE/FSS ENGR CTR
02/09/2016 1404046
THIS DRAWING PRODUCED ON ASO REGION MICROSTATION SYSTEM
ATO - TECHNICAL OPERATIONS EASTERN SERVICE AREA
ZMA-D-1404046-E102
F
IE
V
IS
IO
N
FL
E501
E102 SCALE: 1/8" = 1’-0"
PARTIAL POWER SERVICE BUILDING ROOF - LIGHTNING PROTECTION PLAN
LIGHTNING PROTECTION PLANLIGHTNING PROTECTION PLAN
ALUMINUM MAIN CONDUCTOR ON ROOF "B".
LEAD COPPER CONDUCTOR FROM ROOF "D" TO NEW
PROVIDE BI-METAL CONNECTOR TO CONNECT EXISTING DOWN 8
SPLICER CONNECTOR.
TO EXISTING MAIN CONDUCTOR ON ROOF "A". PROVIDE NEW
CONNECT NEW LIGHTNING MAIN CONDUCTOR ON ROOF "B" 7
BUILDING COUNTERPOISE.
BI-METAL CONNECTOR TO EXISTING COPPER CABLE TO
CONNECTION TO EXISTING DOWN CONDUCTOR. PROVIDE 6
LIGHTNING PROTECTION LOOP USING MAIN SIZE CONDUCTOR.
PROVIDE HEAVY-DUTY BONDING LUG/PLATE. CONNECT TO 5
ON ROOF. SEE DETAIL 4 ON DRAWING E501.
PROVIDE BONDING STRAP AND CONDUCTOR FOR VENT PIPE 4
DRAIN.
PROVIDE BONDING LUG AND CONDUCTOR FOR METAL ROOF 3
FASTEN EVERY 3 FEET MAX.
CLASS II ALUMINUM CONDUCTOR RUNNING ON PARAPET WALL. 2
MOUNTED HORIZONTALLY ON PARAPET WALL.
CLASS II ALUMINUM AIR TERMINAL 5/8"x 24" WITH BASE 1
CONDUCTOR. COORDINATE WITH ARCHITECTURE.
BOND NEW SAFETY RAILING TO MAIN LIGHTNING 12.
MANUFACTURER PRIOR TO INSTALLATION.
SUBMITTAL FROM LIGHTNING PROTECTION
CONTRACTOR TO PROVIDE APPROVED SHOP DRAWING 11.
ROOFING CONTRACTOR.
SHALL BE COORDINATED AND INSTALLED BY THE
INSTALLATION OF THE LIGHTNING PROTECTION SYSTEM
SPECIAL ROOFING MATERIALS REQUIRED FOR THE
ROOF PADS, PAVERS, FLASHINGS OR ANY OTHER 10.
MANUFACTURER.
ROOFING MEMBRANE - VERIFY WITH ROOFING
CONDUCTOR FASTENERS SHALL BE COMPATIBLE WITH
ADHESIVE PRODUCT FOR AIR TERMINAL BASES AND 9.
CODE 175, L.P.I. CODE 117 AND FAA-STD-019e.
SYSTEM SHALL COMPLY WITH NFPA 780, UL-96A, L.P.I.
THE INSTALLATION OF THE LIGHTNING PROTECTION 8.
CONFORM TO NFPA 780.
PER UNDERWRITER’S LABORATORIES (UL) 96A AND
ALL NEW MATERIALS SHALL BE CLASS II AND LABELED 7.
SYSTEM INSTALLATION DETAILS.
REFER TO DRAWING E501 FOR LIGHTNING PROTECTION 6.
MOVEMENT.
CONDUCTORS, BASE) IN PLACE FREE FROM ANY
SECURE ALL COMPONENTS (AIR TERMINALS, 5.
REQUIRED BY U.L. AND L.P.I.
WITH MAIN SIZE CONDUCTORS SHOWN AND AS
BOND ALL METAL BODIES OF CONDUCTANCE ON ROOF 4.
DEGREES OR GREATER.
OR GREATER, AND SHALL HAVE AN ANGLE BEND OF 90
CONDUCTOR SHALL HAVE A RADIUS BEND OF 8 INCHES
HORIZONTAL OR DOWNWARD PATH. ALL BENDS IN THE
ALL LIGHTNING CONDUCTORS ARE TO MAINTAIN A 3.
LOCATIONS SHALL BE FIELD VERIFIED
COMPONENTS ON THE ROOF ARE APPROXIMATE. EXACT
LOCATION OF LIGHTNING PROTECTION SYSTEM 2.
FOR THE GOVERNMENT.
CONDITIONS TO PRODUCE AN ACCEPTABLE PRODUCT
INFORMATION PROVIDED HERE WITH EXISTING SITE
CONTRACTOR TO VERIFY AND CONFIRM ALL
PROCESS. IT IS THE RESPONSIBILITY OF THE
TO BE ENCOUNTERED DURING THE CONSTRUCTION
NOT INTENDED TO SHOW ALL POSSIBLE CONDITIONS
THESE DRAWINGS ARE SCHEMATIC IN NATURE AND ARE 1.
STEEL LADDER
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
REV DESCRIPTION JCN
DATE
REDLINE
APVD
SUBMITTED BY APPROVED BY
JCN
DRAWN
CHECKED
REV
ISSUED BY
H
G
F
E
D
C
B
A
H
G
F
E
D
C
B
A
8 1234567
8 1234567
DATE
DRAWING NO
DESIGNED
REVIEWED BY
:1
:3
D a n ie l D o b y
DATE
APPROVED
Z M
A
D
E .d
M
IS
S
U
R
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
A
D
E .d g n
90% DESIGN
E D
M
IS
S
U
R
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
DO
NOT
SI
GN
A
D
E .d g n
NOT TO SCALEE501
AIR TERMINAL AND CABLE HOLDER INSTALLATION
TEE SPLICER
#A706 ALUM
ALUMINUM (NEW)
ROOF DRAIN
LADDER
FLASHING
CLAMP ALUM
FLAT METAL
CABLE TO
# A142X:
ALUM
BOND CLAMP
#A240X:
ALUM
BOND STRAP
#A800:
ALUM
BOND LUG
# A551:
VENT
ALUM
BOND LUG
#A561:
ALUM SPLICER
#A423:
ALUM
BOND PLATE
#A702:
ALUM
SPLICER
#A141:
BONDING LUG
#A561: CAST ALUMINUM
ALUMINUM CONDUCTOR
#509: 10STR. X 14GA. BARE
SPLICER
#229S:BIMETAL
CONDUCTOR)
(EXISTING DOWN
COPPER CABLE
NOT TO SCALEE501
DOWN CONDUCTOR CONNECTION DETAIL
#A706 TEE SPLICER
RADIUS
MIN. 8"
F
IN
IS
H
A D
E
M
IN
M
IN
TYPICAL FLASHING
FOR SLOPED FLASHING
ADJUSTABLE ADAPTER A27
(BLUNT) OR A571BT WITH
THOMPSON #A571BT
AIR TERMINAL 5/8"x 24"
ADHESIVE 731-G
EQUAL USE THOMPSON
THOMPSON #A688 OR
ADHESIVE POINT BASE
MAIN CONDUCTOR
#A37 ALUMINUM
WITH ADAPTER
TERMINAL, BLUNT TIP,
SOLID ALUMINUM AIR
NO. A571BT, 5/8" X 24"
CABLE GUARD
EXISTING PVC
ROD/COUNTERPOISE
CABLE TO GROUND
EXISTING COPPER
ROD/COUNTERPOISE
CABLE TO GROUND
EXISTING COPPER
SPLICER
BI-METAL
NO. 229S,
PER 1000’)
#13AWG WIRES - 190 LBS.
CONDUCTOR (37 STRANDS OF
NO. A37, CLASS II, ALUMINUM
STRUCTURE
BUILDING
HOLDER @ 3’-0" O/C
ADHESIVE CABLE
#A186X: CAST ALUM
NOT TO SCALEE501
DOWN LEAD CONNECTION DETAIL
NOT TO SCALEE501
ROOF DRAIN BONDING DETAIL
THOMPSON ADHESIVE 731-G
EVERY 3’-0" INTERVAL USE
ADHESIVE CABLE HOLDER (A730)
ADHESIVE 731-G
EQUAL USE THOMPSON
THOMPSON #A688 OR
ADHESIVE POINT BASE
CONDUCTOR
BARE ALUMINUM
NO. A37 CLASS 2
FLASHING (TYP.)
PARAPET WALL
NOT TO SCALEE501
BONDING CONNECTORS AND INSTALLATION HARDWARE
NOT TO SCALEE501
AIR TERMINAL AND CABLE HOLDER INSTALLATION
SUBMITTAL REQUIREMENTS.
IS CALLED OUT TO ESTABLISH A DESIGN. SEE SPECIFICATION FOR
FOR THIS DRAWING THOMPSON LIGHTNING PROTECTION HARDWARE 1.
FL
DM
DM 02/09/2016 1404046
ENGINEERING SERVICES
ENROUTE/FSS
LIGHTNING PROTECTION DETAILS
PARTIAL ROOF REPLACEMENT
POWER SERVICE BUILDING
PROJECT ENGINEER MGR: ENROUTE/FSS ENGR CTR
THIS DRAWING PRODUCED ON ASO REGION MICROSTATION SYSTEM
EASTERN SERVICE AREA
ZMA-D-1404046-E501
F
IE
V
IS
IO
N
ENGINEERING SERVICES
ENROUTE/FSS
LIGHTNING PROTECTION DETAILS
PARTIAL ROOF REPLACEMENT
POWER SERVICE BUILDING
DM
DM
PROJECT ENGINEER MGR: ENROUTE/FSS ENGR CTR
02/09/2016 1404046
THIS DRAWING PRODUCED ON ASO REGION MICROSTATION SYSTEM
EASTERN SERVICE AREA
ZMA-D-1404046-E501
F
IE
V
IS
IO
N
FL
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
REV DESCRIPTION JCN
DATE
REDLINE
APVD
SUBMITTED BY APPROVED BY
JCN
DRAWN
CHECKED
REV
ISSUED BY
H
G
F
E
D
C
B
A
H
G
F
E
D
C
B
A
8 1234567
8 1234567
DATE
DRAWING NO
DESIGNED
REVIEWED BY
:1
:0
P
M D a n ie l D o b y
DATE
APPROVED
Z M
A
D
E .d
| ZMA-D-1404046-G001 |
| ZMA-D-1404046-G002 |
| ZMA-D-1404046-A101 |
| ZMA-D-1404046-A102 |
| ZMA-D-1404046-A103 |
| ZMA-D-1404046-A501 |
| ZMA-D-1404046-A502 |
| ZMA-D-1404046-E101 |
| ZMA-D-1404046-E102 |
| ZMA-D-1404046-E501 |
File details come from the government source that posted it. Updated .