TYS-1003480- Bid Drawings.pdf
PDF 3 MB Posted
- Solicitation number
- DTFAEN-14-R-00036
About this file
TYS-1003480- Bid Drawings (pdf)
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Q A 14-R-00036.docx | DOCX document | |
| DIV 7 Master.pdf | ||
| DIV 5 Master.pdf | ||
| DIV 1 Master.pdf | ||
| FAA Form 3900-18 04.16.2013.pdf | ||
| TYS-1003480- Bid Drawings.pdf | ||
| DIV 26 Master.pdf | ||
| FAA-STD-019e.pdf | ||
| DIV 2 Master.pdf | ||
| DIV 7 Master.pdf | ||
| FAA-STD-019e.pdf | ||
| DIV 2 Master.pdf | ||
| FAA Form 3900-18 04.16.2013.pdf | ||
| DIV 26 Master.pdf | ||
| DIV 1 Master.pdf | ||
| DIV 5 Master.pdf | ||
| DIV 26 Master.pdf | ||
| DIV 5 Master.pdf | ||
| DIV 2 Master.pdf | ||
| DIV 7 Master.pdf | ||
| FAA-STD-019e.pdf | ||
| FAA Form 3900-18 04.16.2013.pdf | ||
| DIV 1 Master.pdf |
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
IS
S
U E
D
F O
R
C
N S
T R
U C
T
IO
N
ATCT
MC GHEE TYSON AIRPORT
TERMINAL
ATO - TECHNICAL OPERATIONS EASTERN SERVICE AREA
ENGINEERING SERVICES
WATERPROOFING AND OSH IMPROVEMENT PROJECT
LMC
BP
PROJECT ENGINEER MGR: ENGINEERING - CENTER A
11/01/2013 TYSATCT
TN
COVER SHEET AND DRAWING INDEX
GENERAL
KNOXVILLE
TYS-D-1003480-G001
DRAWING LIST
DRAWING NO. DESCRIPTIONREV. DATE
TYS-D-1003480-E003
TYS-D-1003480-E002
TYS-D-1003480-E001
TYS-D-1003480-S001
TYS-D-1003480-H001
TYS-D-1003480-G003
TYS-D-1003480-G002
TYS-D-1003480-G001
11-01-2013
11-01-2013
11-01-2013
11-01-2013
11-01-2013
11-01-2013
11-01-2013
11-01-2013
WATERPROOFING AND OSH IMPROVEMENT PROJECT ELECTRICAL AIR TERMINAL DETAILS - BASE BUILDING
WATERPROOFING AND OSH IMPROVEMENT PROJECT ELECTRICAL GROUNDING DETAILS
WATERPROOFING AND OSH IMPROVEMENT PROJECT ELECTRICAL LIGHTNING PROTECTION
WATERPROOFING AND OSH IMPROVEMENT PROJECT STRUCTURAL SAFETY HANDRAIL DETAILS
WATERPROOFING AND OSH IMPROVEMENT PROJECT HAZMAT ASBESTOS MATERIAL LOCATION SUMMARY
WATERPROOFING AND OSH IMPROVEMENT PROJECT GENERAL PROJECT PHOTOS
WATERPROOFING AND OSH IMPROVEMENT PROJECT GENERAL BASELINE BASE BUILDING ROOF AND GENERAL DIMENSIONS
WATERPROOFING AND OSH IMPROVEMENT PROJECT GENERAL COVER SHEET AND DRAWING INDEX
Courtney J. NolanBrian Papagni
AVIA
T
I O
N
L A
R
E D
E F
TRAT
IO
N
SI
NI
M
D A
02/06/2014
ISSUED FOR BID
McGHEE TYSON AIRPORT
WATERPROOFING AND OSH IMPROVEMENT PROJECT
ATCT - KNOXVILLE, TENNESSEE
A
T OF TRANSPO
R T A T
IO
N
M
E R
IC
A
OF
STATES
U N
IT
E D
D E P A
R
TM
EN
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
REV DESCRIPTION JCN
DATE
REDLINE
APVD
SUBMITTED BY APPROVED BY
JCN
DRAWN
CHECKED
REV
ISSUED BY
H
G
F
E
D
C
B
A
H
G
F
E
D
C
B
A
8 1234567
8 1234567
DATE
DRAWING NO
DESIGNED
REVIEWED BY
:2
:0
P M
P lo t t e d b y le w is c t r c u r t is
DATE
APPROVED
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
REV DESCRIPTION JCN
DATE
REDLINE
APVD
SUBMITTED BY APPROVED BY
JCN
DRAWN
CHECKED
REV
ISSUED BY
H
G
F
E
D
C
B
A
H
G
F
E
D
C
B
A
8 1234567
8 1234567
DATE
DRAWING NO
DESIGNED
REVIEWED BY
:2
:0
P lo t t e d b y le w is c t r c u r t is
IS
S
U
TN
LMC
BP 11/01/2013 TYSATCT
N S
T R
U C
T
IO
ENGINEERING SERVICES
ROOF AND GENERAL DIMENSIONS
GENERAL BASELINE BASE BUILDING
WATERPROOFING AND OSH IMPROVEMENT PROJECT
MC GHEE TYSON AIRPORTKNOXVILLE
PROJECT ENGINEER MGR: ENGINEERING - CENTER A
TYS-D-1003480-G002
PRECAST JOINTS
HORIZONTAL
EIGHT TYPICAL
PRECAST JOINTS
VERTICAL
FOUR TYPICAL
.6
98.6667’
8.0207’
34.5’
.9
.5
51.1667’
.4
.5
13’
08’ 8’
SCALE: 1/8" = 1’-0"
16’
G002 NOT TO SCALE
TOWER ELEVATION
G002
BASELINE BASE BUILDING ROOF PLAN
TOWER
Courtney J. NolanBrian Papagni
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
REV DESCRIPTION JCN
DATE
REDLINE
APVD
SUBMITTED BY APPROVED BY
JCN
DRAWN
CHECKED
REV
ISSUED BY
H
G
F
E
D
C
B
A
H
G
F
E
D
C
B
A
8 1234567
8 1234567
DATE
DRAWING NO
DESIGNED
REVIEWED BY
:2
:1
P lo t t e d b y le w is c t r c u r t is
H
G
F
E
D
C
TOWER CAB
METAL PANEL JOINT
BASE BUILDING (2)
BASE BUILDING(1)
ATCT (1)
ATCT(2)
IS
S
U
GENERAL
BP 11/01/2013 TYSATCT
N S
T R
U C
T
IO
PROJECT PHOTOS
TYS-D-1003480-G003
Courtney J. NolanBrian Papagni
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
REV DESCRIPTION JCN
DATE
REDLINE
APVD
SUBMITTED BY APPROVED BY
JCN
DRAWN
CHECKED
REV
ISSUED BY
H
G
F
E
D
C
B
A
H
G
F
E
D
C
B
A
8 1234567
8 1234567
DATE
DRAWING NO
DESIGNED
REVIEWED BY
:2
:2
P lo t t e d b y le w is c t r c u r t is
JANITOR
LOCKERS
STORAGE
BASE BUILDING AF SHOP WHITE THERMAL INSULATION SEALANT
BASE BUILDING BREAK WHITE THERMAL INSULATION SEALANT
BASE BUILDING EG WHITE THERMAL INSULATION SEALANT; GENERATOR GASKET; MUFFLER INSULATION
BASE BUILDING WHITE THERMAL INSULATION SEALANT
BASE BUILDING WHITE THERMAL INSULATION SEALANT
BASE BUILDING MEN’S WHITE THERMAL INSULATION SEALANT
BASE BUILDING WOMEN’S WHITE THERMAL INSULATION SEALANT
BASE BUILDING WHITE THERMAL INSULATION SEALANT
PUMP
CAB
WHITE THERMAL INSULATION SEALANT
WHITE THERMAL INSULATION SEALANT
WHITE THERMAL INSULATION SEALANT
WHITE THERMAL INSULATION SEALANT
WHITE THERMAL INSULATION SEALANT
WHITE THERMAL INSULATION SEALANT
WHITE THERMAL INSULATION SEALANT
WHITE THERMAL INSULATION SEALANT
ELEVATOR LOBBY LEVEL
SECOND ENTRY
SECOND ELEVATOR LOBBY
THIRD ELEVATOR LOBBY
FOURTH LAVATORY
FOURTH PLUMBING SHAFT
SUB-JUNCTION MECHANICAL
CAB
IS
S
U
ORIGINAL SIGNED BY: ORIGINAL SIGNED BY:
ASBESTOS MATERIAL LOCATION SUMMARY
TYSATCT
TERMINAL
TN
LMC
AJ 11/01/2013
ATO - TECHNICAL OPERATIONS EASTERN SERVICE AREA
ENGINEERING SERVICES
HAZMAT
WATERPROOFING AND OSH IMPROVEMENT PROJECT
PROJECT ENGINEER MGR: ENGINEERING - CENTER A
C O
N S
T R
U C
T
IO
N
PROCEDURES FOR HANDLING ASBESTOS MATERIALS.
2. REFER TO SPECIFICATIONS AND APPENDICES FOR STANDARD OPERATING
SPECIFICATIONS. THE COMPLETE REPORT IS ON FILE WITH THE FAA.
CONSULTANTS, INC. A SUMMARY OF THIS REPORT IS INCLUDED IN THE
LOCATIONS AS CONTAINED IN THE REPORT PREPARED BY RESEARCH MANAGEMENT
THIS DRAWING IS A SUMMARY OF ASBESTOS CONTAINING MATERIAL (ACM)
1. BUILDING CONTAINS HAZARDOUS MATERIAL (HAZMAT) LOCATIONS. SHOWN ON
HAZMAT NOTES
SUSPECTED ASBESTOS MATERIAL LOCATION SUMMARY
(SEE SPECIFICATIONS FOR ACM REPORT)
ASBESTOS MATERIAL (ACM)ROOM NAME
FLOOR LEVEL
Courtney J. NolanBrian Papagni
TYS-D-1003480-H001
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
REV DESCRIPTION JCN
DATE
REDLINE
APVD
SUBMITTED BY APPROVED BY
JCN
DRAWN
CHECKED
REV
ISSUED BY
H
G
F
E
D
C
B
A
H
G
F
E
D
C
B
A
8 1234567
8 1234567
DATE
DRAWING NO
DESIGNED
REVIEWED BY
:2
:3
P lo t t e d b y le w is c t r c u r t is
X X X X X X X X X X X X X X X X X X X X X X X X
X X X X X X X X X X X X X X X X X X X X X X X X
X X X X X X X X X X X X X X X X X X X X X X X X
0.75"
3"3/16"
EXISTING C4x 5.4
3/8" Ø A307 (TYP)
3"3/16"
PARAPET WALL
TOP OF EXISTING
FLANGE TYPE #68-6
KEE KLAMP WALL
FLANGE TYPE #68-6
KEE KLAMP WALL
TYPE #68-6
WALL FLANGE
KEE KLAMP
3"3/16"
3/16"
3/16"
3/8" Ø A307 (TYP)
0.75"
TYPE #68-6
WALL FLANGE
KEE KLAMP
TYPE #68-6
WALL FLANGE
KEE KLAMP
TYPE #26-6
TWO SOCKET CROSS
KEE KLAMP
TYPE #26-6
TWO SOCKET CROSS
KEE KLAMP
TYPE #26-6
TWO SOCKET CROSS
KEE KLAMP
TYPE #26-6
TWO SOCKET CROSS
KEE KLAMP
TYPE #25-6
THREE SOCKET TEE
KEE KLAMP
TYPE #25-6
THREE SOCKET TEE
KEE KLAMP
TYPE #25-6
THREE SOCKET TEE
KEE KLAMP
TYPE #25-6
THREE SOCKET TEE
KEE KLAMP
STEEL PIPE
NO. 6 GALVANIZED STEEL PIPE
NO. 6 GALVANIZED
STEEL PIPE
NO. 6 GALVANIZED
STEEL PIPE
NO. 6 GALVANIZED
STEEL PIPE
NO. 6 GALVANIZED
STEEL PIPE
NO. 6 GALVANIZED
STEEL PIPE (TYP)
NO. 6 GALVANIZED
STEEL PIPE (TYP)
NO. 6 GALVANIZED
PARAPET WALL
TOP OF EXISTING
PARAPET WALL
TOP OF EXISTING
PARAPET WALL
TOP OF EXISTING
.2
.7
.2
.7
1.5" 11" 1.5"
14"Lx 6"Wx 1/2" P 14"Lx 6"Wx 1/2" PLL
SIDE VIEW ELEVATION VIEW
PLAN VIEW
SIDE VIEW ELEVATION VIEW
S001
CANOPY BASE BUILDING ROOF PARAPET
HANDRAIL CONNECTIONS @ LINK AND
SCALE: 3" = 1’-0"
IS
S
U
AJ 11/01/2013 TYSATCT
N S
T R
U C
T
IO
NOTE
L
L5x 5x 3/8"x 8" LG
NEW
L5x 5x 3/8"x 8" LG
NEW4
.1
.7
.1
.1
7"
INSTEAD.
P FOR 3/8" A307 BOLTS
TAPPING HOLES IN STEEL
DIFFICULT CONSIDER
STEEL. WELDING CAN BE
ANCHOR IS GALVANIZED
3/8" Ø A307 BOLTS, TYP.
*8 .7
.1
ASSEMBLY
CONNECTION>
ASSEMBLY
CONNECTION>
ASSEMBLY
CONNECTION>
ASSEMBLY
CONNECTION>
L5x 5x 3/8"x 8" LG
NEW
C4x 5.4
EXISTING
C4x 5.4
EXISTING
LOCATED AT 4’-0" O.C.
FRAMES ARE TO BE
LOCATED AT 4’-0" O.C.
FRAMES ARE TO BE
LOCATED AT 4’-0" O.C.
FRAMES ARE TO BE
LOCATED AT 4’-0" O.C.
FRAMES ARE TO BE
S001
ROOF PRECAST CONCRETE PARAPET
BASE BUILDING HANDRAIL CONNECTIONS
SCALE: 3" = 1’-0"
SAFETY HANDRAIL DETAILS
STRUCTURAL
WATERPROOFING AND OSH IMPROVEMENT PROJECT
TYS-D-1003480-S001
3" 0 3" 9"6"
SCALE: 3" = 1’-0"
Courtney J. NolanBrian Papagni
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
REV DESCRIPTION JCN
DATE
REDLINE
APVD
SUBMITTED BY APPROVED BY
JCN
DRAWN
CHECKED
REV
ISSUED BY
H
G
F
E
D
C
B
A
H
G
F
E
D
C
B
A
8 1234567
8 1234567
DATE
DRAWING NO
DESIGNED
REVIEWED BY
:2
:4
P lo t t e d b y le w is c t r c u r t is
8 0 8 16
1/8" = 1’-0"
E/G EXHAUST
HOOD
CM ESTABLISHED PER CCD # 21952
CAB
HOOD
HOOD
HOOD
A/C 7.5 TON
CAB
ANTENNA
TV
SWITCH
DISCONNECT
SWITCH
DISCONNECT
N
(15 TONS)
RTU-2
(30 TONS)
RTU-1
2 TYPICAL
IS
S
U
N S
T R
U C
T
IO
LIGHTNING PROTECTION
ELECTRICAL
TNMC GHEE TYSON AIRPORTKNOXVILLE
WATERPROOFING AND OSH IMPROVEMENT PROJECT
ANTENNA
THAN THE TALLEST FAA
SHOULD BE 10" TALLER
THESE AIR TERMINALS
HANDRAIL SYSTEM.
TO BE MOUNTED ON TOP OF
CONDUCTORS AND AIR TERMINALS
LIGHTNING PROTECTION
FAA ANTENNA MOUNTS
SHALL BE BONDED TO THE COUNTERPOISE.
6. ALL METALLIC OBJECTS WITHIN 6’ OF ROOF COUNTERPOISE
REQUIREMENTS.
COMPLY WITH NFPA 780 - CLASS II SYSTEM INSTALLATION
5. ALL LIGHTNING PROTECTION SYSTEM COMPONENTS SHALL
GOVERNMENT UPON PROJECT COMPLETION.
EDITION." THE UL MASTER LABEL SHALL BE FURNISHED TO THE
LIGHTNING PROTECTION SYSTEMS, UL96A - MOST CURRENT
SYSTEM SHALL MEET THE "INSTALLATION REQUIREMENTS FOR
4. THE COMPLETED GROUNDING AND LIGHTNING PROTECTION
MOUNTS SEE DETAIL SHEETS E002.
3. FOR CONNECTIONS TO ROOF DRAINS, HOODS, AND ANTENNA
SHEET E003.
2. LIGHTNING PROTECTION AIR TERMINAL, SEE DETAIL 3, ON
13 FOR MORE DETAILS.
PVC CONDUIT. SEE LIGHTNING PROTECTION SPECIFICATION 26 41
DOWN CONDUCTOR 6’ ABOVE FINISHED GRADE WITH SCHEDULE 40
EXOTHERMICALLY WELDED TO EXISTING COUNTERPOISE. PROTECT
1. LIGHTNING PROTECTION DOWN CONDUCTOR SHOULD BE
Courtney J. NolanBrian Papagni
TYS-D-1003480-E001
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
REV DESCRIPTION JCN
DATE
REDLINE
APVD
SUBMITTED BY APPROVED BY
JCN
DRAWN
CHECKED
REV
ISSUED BY
H
G
F
E
D
C
B
A
H
G
F
E
D
C
B
A
8 1234567
8 1234567
DATE
DRAWING NO
DESIGNED
REVIEWED BY
:2
:4
P lo t t e d b y le w is c t r c u r t is
3/8" BOLT HOLE
BONDING LUG WITH
THOMPSON #551
DOME ROOF DRAIN
DRILL AND TAP ROOF DRAIN
FLANGE AND CONNECT BONDING
CONNECTOR TO DRAIN FLANGE
VENT POINT
THOMPSON NO. 655
VENT POINT SUPPORT
THOMPSON NO. 657
COUPLER
THOMPSON NO. 656
ROD CONNECTOR
THOMPSON NO. 693
VENT ROD
THOMPSON NO 654
HOLE
LUG WITH 3/8" BOLT
THOMPSON #551 BONDING
FLASHING CAP
METAL PIPE VENT INSIDE
VENT POINT
THOMPSON NO. 655
COUPLER
THOMPSON NO. 656
ROD CONNECTOR
THOMPSON NO. 693
VENT POINT SUPPORT
THOMPSON NO. 657
ROOF CONDUCTOR
VENT ROD
THOMPSON NO 654
IS
S
U
N S
T R
U C
T
IO
GROUNDING DETAILS
ELECTRICAL
TYS-D-1003480-E002
3A1 2
WITH STAINLESS STEEL BOLT
3B
AIR TERMINAL
(OR APPROVED EQUAL)
THOMPSON NO. 675
BONDING CONDUCTOR
CLASS II PRIMARY
ROOF CONDUCTOR
CONNECT TO CLASS II
AIR TERMINAL
(OR APPROVED EQUAL)
THOMPSON NO. 675
BASE
THOMPSON NO. 688
BASE
THOMPSON NO. 688
PRIMARY BONDING CONDUCTOR
CLASS II
E002E002E002
E002
ROOF
PARAPET WALL
TOP OF EXISTING
SERIES PIPE CLAMP.
ANCHORED TO TOP RAIL W/ THOMPSON #240
LIGHTNING PROTECTION AIR TERMINAL
METAL RAIL SYSTEM
IN
IM
U M
AIR TERMINAL GROUNDING
EXHAUST FAN HOOD
GROUNDING
EXHAUST FLUE
ROOF VENT GROUNDINGROOF DRAIN GROUNDING
HANDRAIL AIR TERMINAL GROUNDING
NOT TO SCALENOT TO SCALENOT TO SCALENOT TO SCALE
NOT TO SCALE
E002
Courtney J. NolanBrian Papagni
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
REV DESCRIPTION JCN
DATE
REDLINE
APVD
SUBMITTED BY APPROVED BY
JCN
DRAWN
CHECKED
REV
ISSUED BY
H
G
F
E
D
C
B
A
H
G
F
E
D
C
B
A
8 1234567
8 1234567
DATE
DRAWING NO
DESIGNED
REVIEWED BY
:2
:5
P lo t t e d b y le w is c t r c u r t is
L
PH
U
L
3 AIR TERMINAL DETAIL
L
PH
U
L
1 2
- 375 LBS. PER 1000’)
(28 STRANDS OF 14 AWG WIRES
LIGHTNING CONDUCTOR
NO. 28R, CLASS II COPPER
UNIVERSAL BASE
NO. 611 CA, COPPER
MAX.
FASTENER EVERY 3’
ADHESIVE CABLE
NO. 730 CA, COPPER
STRAP TYPE PIPE CLAMP
NO. A704, ALUMINUM
NO. 704, TINNED COPPER
CROSS RUN CONNECTOR
NO. A637, ALUMINUM
NO. 637, BRONZE
CONNECTOR
NO. 229, BIMETAL
U-BOLT TYPE PIPE CLAMP
NO. A802, ALUMINUM
NO. 802, TINNED BRONZE
CABLE TO FLAT METAL CLAMP
NO. A142, ALUMINUM
NO. 142, BRONZE
BONDING PLATE
NO. A702, ALUMINUM
NO. 702, TINNED BRONZE
1 BOLT PARALLEL CLAMP
NO. A141, ALUMINUM
NO. 141, BRONZE
SECONDARY BONDING LUG
NO. A551, ALUMINUM
NO. 551, BRONZE
BULLET TIPPED SOLID
COPPER AIR TERMINAL
215 LBS. PER 1000’)
LIGHTNING CONDUCTOR (32
STRANDS OF 17 AWG WIRES -
WITH STAINLESS STEEL
FASTENER - EVERY 3’ MAX.
UNIVERSAL BASE MOUNTED
WITH STAINLESS STEEL
FASTENERS
NO. 571BT, 5/8" X 24"
NO. 611, BRONZE
NO. 168M, COPPER CABLE CLIP
SOLID COPPER AIR TERMINAL
NO. 668-5, 5/8 " X 60"
STEEL TRIPOD BRACE 48" HIGH
NO. 83-5 CA, GALVANIZED
NO. 32, CLASS II COPPER
IS
S
U
N S
T R
U C
T
IO
AIR TERMINAL DETAILS - BASE BUILDING
ELECTRICAL
E003 E003 E003
WATERPROOFING AND OSH IMPROVEMENT PROJECT
TYS-D-1003480-E003
H250
H250
NOTES
TYPICAL BONDING/SPICING DETAILS AIR TERMINAL DETAIL
NOT TO SCALENOT TO SCALENOT TO SCALE
FASTENERS. TYPICAL FOR ALL BASE PLATES.
BY THE ROOFING MANUFACTURER. DO NOT PENETRATE ROOFING WITH MECHANICAL
3. MOUNT BASE PLATES TO BUILDING ROOF WITH COPPER ADHESIVE AS RECOMMENDED
2. ALL BENDS IN ROOF AND DOWN CONDUCTORS SHALL HAVE A MINIMUM 8" RADIUS.
1. MODEL NUMBERS SHOWN ARE BASED ON THOMPSON, OR APPROVED EQUAL.
Courtney J. NolanBrian Papagni
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
REV DESCRIPTION JCN
DATE
REDLINE
APVD
SUBMITTED BY APPROVED BY
JCN
DRAWN
CHECKED
REV
ISSUED BY
H
G
F
E
D
C
B
A
H
G
F
E
D
C
B
A
8 1234567
8 1234567
DATE
DRAWING NO
DESIGNED
REVIEWED BY
:2
:0
P
M P lo t t e d b y le w is c t r c u r t is
| tys-d-1003480-g001 |
| Saved Views |
| BLANK |
| preview |
| References |
| border, faadborder.dgn |
| border-1, faadborder.dgn |
| tys-d-1003480-g002 |
| Saved Views |
| BLANK |
| preview |
| References |
| border, faadborder.dgn |
| tys-d-1003480-g003 |
| Saved Views |
| preview |
| References |
| border, faadborder.dgn |
| TYS-D-1003480-H001 |
| References |
| border, faadborder.dgn |
| TYS-D-1003480-S001 |
| Saved Views |
| BLANK |
| preview |
| References |
| border, faadborder.dgn |
| TYS-D-1003480-E001 |
| Saved Views |
| preview |
| References |
| border, faadborder.dgn |
| TYS-D-1003480-E002 |
| Saved Views |
| CAB |
| PLOT |
| preview |
| References |
| border, faadborder.dgn |
| TYS-D-1003480-E003 |
| Saved Views |
| PLOT |
| preview |
| References |
| border, faadborder.dgn |
File details come from the government source that posted it. Updated .