About this file
This file contains architectural drawings and specifications for exterior renovations to the Floyd County Courthouse located at 366 Plainville Road NE, Rome, Georgia 30161, prepared by E Dunay Design, LLC. The scope of work addresses drainage improvements, masonry restoration, and exterior finishes, including cleaning and recaulking gutters; adding underground piping and drain grates to connect downspouts to stormwater lines; installing new concrete trenches with grates from downspouts to the road; adding one new downspout with associated piping and drains; cleaning, caulking, and painting exterior wood and metal trim; repointing masonry; sealing terracotta tile; repairing and repointing masonry above attic windows; and reseeding disturbed grass areas. The drawings include a site plan showing drainage details, existing condition photographs documenting current building conditions at multiple locations including cornices, chimneys, gutters, dormers, and towers, and detailed elevation drawings of the front, rear, left, and right facades with specific renovation notes and measurements for each section.
The documents provide technical specifications for construction activities including OSHA-compliant entrance protection, stormwater system connections using 6-inch and 8-inch piping, French drain installation below window wells, masonry stabilization and repointing of approximately 650 square feet, and attic masonry details with anchoring options using Hilti helical wall ties or threaded rods. Construction sequencing requires temporary closure and relocation of parking spaces during work completion and mandates contact with Georgia 811 before any excavation. The drawings were prepared with a status date of August 1, 2025, project number 2423, and identify the design professional contact as beth@edunaydesign.com with phone number 706-766-0366.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| NOTICE OF INTENT TO AWARD.pdf | ||
| 25_028 EXTERIOR RENOVATION FLOYD COUNTY HISTO.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C :\U se rs
\b du na \D oc um en ts
\jo bs
\c ou rth ou se \c ou rth ou se p 1.
pl n
FL
O
YD
C
O C
O U
RT
H
O U
SE
RO
M
E, G
A
G
O V
ER
N
M
EN
T
PL
A
ZA
RE
N
O V
A
TI
O N
S
TO
T H
E
366 PLAINVILLE RD NE
ROME, GEORGIA 30161
ph_706 766-0366
E DUNAY DESIGN, LLC
A.0.1
STATUS: SD
DATE: 8/1/2025
PROJECT # 2423
COVER SHEET
beth@edunaydesign.com
REVISIONS
4"
MIN.
6"
4"
MIN.
4" M
IN
V
A
RI
ES
EXISTING
CONCRETE
HEAVY DUTY
DUCTILE IRON
CHANNEL GRATE
NEW
CONCRETE
8" HEAVY DUTY TRENCH
CHANNEL WITH GRATE
NEW FRENCH DRAIN FROM BELOW THE
WINDOW WELL SLAB TO DOWNSPOUT PIPING
EXISTING 6" PIPE
NEW 8" PVC PIPE TO STORM WATER LINE
CONSTRUCTION BARRIER.
RELOCATE & REOPEN PARKING SPACES
ONCE NEW WORK IS COMPLETED
CONSTRUCTION BARRIER AS NEEDED,
LIMIT TIME USED AS MUCH AS POSSIBLE
NEW CURB & GUTTER
AS NEEDED
NEW 6" DRAIN & GRATE
NEW 8" DRAIN & GRATE
NEW 6" PIPE
NEW DOWNSPOUT
ALIGN WITH DOWNSPOUT
CLEAN MASONRY
REPOINT & SEAL THIS AREA
CLEAN MASONRY
REPOINT & SEAL THIS AREA
PROVIDE OSHA COMPLIANT
PROTECTION AT ENTRANCES
PROVIDE OSHA COMPLIANT
PROTECTION AT ENTRANCES
EXISTING STORM
WATER SYSTEM
PATCH SIDEWALK
AS NEEDED
NOTE: CALL GEORGIA 811 BEFORE DIGGING.
A.0.1
A.0.1
SCALE: 1" = 1'-0"1 DRAIN DETAIL
SCALE: 1" = 10'2 LEFT ELEVATION
SCOPE OF WORK
1. CLEAN AND RECAULK GUTTERS.
2. ADD NEW UNDERGROUND PIPING AND DRAIN GRATES FROM DOWNSPOUTS TO STORMWATER LINES.
3. INSTALL NEW CONCRETE TRENCHES FROM DOWNSPOUT TO ROAD.
4. ADD ONE NEW DOWNSPOUT, PIPING DRAINS AND GRATES TO STORM WATER LINES.
5. CLEAN, CAULK AND PAINT ALL EXTERIOR WOOD AND METAL TRIM, NOT INCLUDING WINDOWS AND WINDOW TRIM.
6. REPOINT MASONRY AS NOTED.
7. SEAL ALL TERRACOTTA TILE.
8. REPAIR AND REPOINT MASONRY ABOVE ATTIC WINDOWS.
9. RESEED ALL DISTURBED GRASS AREAS.
SHEET INDEX
A.0.1 SITE PLAN
A.1.0 EXISTING CONDITIONS PHOTOS
A.2.0 ELEVATIONS
A.2.1 ELEVATIONS
EXTERIOR RENOVATIONS TO THE
FLOYD CO COURTHOUSE
se rs
\b du na \D oc um en ts
\jo bs
\c ou rth ou se \c ou rth ou se p 1.
pl n
FL
O
YD
C
O C
O U
RT
H
O U
SE
RO
M
E, G
A
G
O V
ER
N
M
EN
T
PL
A
ZA
RE
N
O V
A
TI
O N
S
TO
T H
E
366 PLAINVILLE RD NE
ROME, GEORGIA 30161
ph_706 766-0366
E DUNAY DESIGN, LLC
A.1.0
STATUS: SD
DATE: 8/1/2025
PROJECT # 2423
EXISTING
CONDITIONS
beth@edunaydesign.com
REVISIONS
1 CORNICE
2 CORNICE
3 TRIM & GUTTER
4 CHIMNEY & GUTTER
5 CHIMNEY & VENTS
6 DORMER & GUTTER
7 TOWER TRIM
8 CHIMNEY & DORMER
9 DORMER
10 GUTTER
11 GUTTER
12 GUTTER
se rs
\b du na \D oc um en ts
\jo bs
\c ou rth ou se \c ou rth ou se p 1.
pl n
FL
O
YD
C
O C
O U
RT
H
O U
SE
RO
M
E, G
A
G
O V
ER
N
M
EN
T
PL
A
ZA
RE
N
O V
A
TI
O N
S
TO
T H
E
366 PLAINVILLE RD NE
ROME, GEORGIA 30161
ph_706 766-0366
E DUNAY DESIGN, LLC
A.2.0
STATUS: SD
DATE: 8/1/2025
PROJECT # 2423
ELEVATIONS
beth@edunaydesign.com
REVISIONS
REPOINT
PARAPET TILES,
SEAL PARAPET
TILES & JOINTS
REPOINT CHIMNEY
ADD PRE-FINIISHED METAL CAP
REATTACH AND CAULK FLASHING EDGES
SCRAPE, PRIME AND PAINT
RECAULK FLASHING
CLEAN AND PAINT
WOOD CEILING
SEAL BRICK FLOOR
STABALIZE BRICK
& REPOINT, SEE 3/A.3.1
CAULK EDGES,
PAINT TRIM & CAP
CAULK TRIM &
FLASHING EDGES,
PAINT TRIM
SEAL ALL
TERRACOTTA
REMOVE MULCH FROM AGAINST
WINDOWS
ADD FRENCH DRAIN BELOW
WINDOW WELL SLAB LEVEL
METAL SILL
SCRAPE, CAULK & PAINT
REATTACH AND CAULK FLASHING EDGES
SCRAPE, PRIME AND PAINT
STABLIZE
MASONRY
& REPOINT
PAINT WOOD CEILING
PAINT LITES AND TRIM.
RESTAIN DOOR EXTERIORS.
PAINT COLUMNS
REPOINT PARAPET
TILES, SEAL
PARAPET TILES &
JOINTS
PAINT METAL FACIA
W/2 COATS OF MARINE PAINT
1'-4"
1 / 4
8"
1 / 4
5" 9 1/4"
+2
FIELD VERIFY ALL DIMENSIONS
AND DETAILS
SCALE: 1/8" = 1'-0"1 RIGHT ELEVATION
SCALE: 1/8" = 1'-0"2 FRONT ELEVATION
SCALE: 1' = 1'-0"3 GUTTER PHOTO
SCALE: 1/4" = 1'-0"4 GUTTER DETAIL
se rs
\b du na \D oc um en ts
\jo bs
\c ou rth ou se \c ou rth ou se p 1.
pl n
FL
O
YD
C
O C
O U
RT
H
O U
SE
RO
M
E, G
A
G
O V
ER
N
M
EN
T
PL
A
ZA
RE
N
O V
A
TI
O N
S
TO
T H
E
366 PLAINVILLE RD NE
ROME, GEORGIA 30161
ph_706 766-0366
E DUNAY DESIGN, LLC
A.2.1
STATUS: SD
DATE: 8/1/2025
PROJECT # 2423
ELEVATIONS
beth@edunaydesign.com
REVISIONS
CAULK TRIM &
PAINT FACIA
CAULK & PAINT
SHUTTER
COPPER FLASHING
CAULK EDGES & JOINTS
REPOINT CHIMNEY
ADD NEW BRONZE
FINISH CAP
REPOINT
PARAPET TILES,
SEAL PARAPET
TILES & JOINTS
REPOINT CHIMNEY
ADD NEW BRONZE FINISH CAP
REATTACH AND CAULK FLASHING EDGES
SCRAPE, PRIME AND PAINT
PRIME RUST & PAINT ROOF HATCH
PRIME VENTS &
PAINT GRAY
CONNECT DOWNSPOUT
TO NEW TRENCH
RECAULK GUTTERS. WHERE
DAMAGED INSTALL LIQUID
RUBBER PATCH
CLEAN BRICK & STONE
REPOINT, REPAIR CRACK, SEAL
~ 5 SF
SCRAPE, CAULK &
PAINT METAL SILL
REATTACH AND CAULK FLASHING EDGES
SCRAPE, PRIME AND PAINT
CLEAN BRICK &
STONE, REPOINT AS
NEEDED & SEAL
~650 SF
SEAL CHIPS
ADD PREFINISHED 4 x 6
BRONZE DOWNSPOUT
STABALIZE BRICK
& REPOINT, SEE 3/A.3.1
PAINT WOOD CEILING
SEAL ALL
TERRA COTTA
CONNECT DOWNSPOUT
TO NEW TRENCH
PAINT ALL DOORS AND
TRIM
PAINT COLUMNS
REPOINT PARAPET
TILES, SEAL
PARAPET TILES &
JOINTS
RECAULK FLASHING
EXISTING ROOF
FRAMING
2 WYTHS OF BRICKS
HILTI HELI TIE
(HELICAL WALL TIE)
@ 32" OC
EXISTING ROOF
FRAMING
2 WYTHS OF BRICKS
3/8" DIA. HILTI HY270
THREADED ROD @
48" OC- EMBED 4"
INSTALL BLOCKING @
ANCHORS -CONNECT
TO FRAMING
W/SIMPSON A34
FRAMING ANGLE
OPTION A
OPTION B
OPTION B
SCALE: 1/8" = 1'-0"1 REAR ELEVATION
SCALE: 1/8" = 1'-0"2 LEFT ELEVATION
SCALE: 1" = 1'-0"3 ATTIC MASONRY DETAIL
File details come from the government source that posted it. Updated .