Drawings MEPF - 561-19-130.pdf

PDF 9 MB Posted

Attached to
Y1DA--Upgrade AHU's and Water-Cooled Equipment
Solicitation number
36C24221B0040
Issued by

About this file

This federal contract opportunity notice seeks proposals for upgrading air handling units and water-cooled equipment at the VA New Jersey Healthcare System campus in East Orange. The project is classified under NAICS code 238220 with a size standard of $16.5 million. The cost estimate range is $2-5 million.

Scope of work includes general construction, HVAC, plumbing and electrical upgrades to deficient equipment in Buildings 1 and 7. Successful offerors must provide construction services, submittals, as-built drawings, and complete the project within 328 calendar days of the notice to proceed. The solicitation will be released on June 4, 2021 with response submittal details provided therein. This project requires bonding. Offerors must be registered in SAM.gov and verified as a service-disabled veteran-owned small business in VIP.vetbiz.gov by the time of proposal submission and award.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Charlotte Engineers, LLP 5838 Monroe Road, Suite 100

Charlotte, NC 28212

704 531 3000

Project No. 4325

CHARLOTTE

ENGINEERS, LLP

5838 MONROE ROAD

CHARLOTTE, NC 28212

(704) 531-3000

CAMPUS SITE PLAN:

VICINITY PLAN:

PROJECT TEAM: MEP/FP

561-19-130

Department of Veterans Affairs - VAMC East Orange AHU & Water-Cooled Equipment Upgrades

Tremont and South Center Street East Orange, NJ 07019

3/11/2021

PROJECT LOCATION

Project No.

Date:

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT STAMPPROGRAM MANAGER

321 4 5 6 7 8 9 10

ENGINEER OF RECORD

Charlotte Engineers, LLP 5838 Monroe Road Charlotte, NC 28212 704-531-3000 Michael Eaves

M L o c a l R e v it F ile s \R e v it

\4

C

E C e n tr a l M o d e l.

rv t

/1

/2

:1

:4

P

M

G-001

COVER SHEET VAMC EAST ORANGE AHU &

WATER-COOLED EQUIPMENT

UPGRADES

EAST ORANGE, NEW JERSEY

561-19-130

3/11/2021 GAT DON

FULLY SPRINKLERED

SHEET INDEX

DRAWING TITLE

MECHANICAL

M-001 MECHANICAL - SYMBOLS, NOTES & DRAWING INDEX

M-002 MECHANICAL - DETAILS

M-003 MECHANICAL - DETAILS AND SCHEDULES

M-004 MECHANICAL - AHU SCHEDULES

M-005 MECHANICAL - SEQUENCE OF OPERATIONS

M-006 MECHANICAL - SEQUENCE OF OPERATIONS

M-007 MECHANICAL - SEQUENCE OF OPERATIONS

M-008 MECHANICAL - AHU SCHEMATICS

MD-1-C-01 MECHANICAL - DEMOLITION - BUILDING 1 - C LEVEL

MD-1-C-02 MECHANICAL - DEMOLITION - BUILDING 1 - C LEVEL

MD-1-B-01 MECHANICAL - DEMOLITION - BUILDING 1 - B LEVEL

MD-1-B-02 MECHANICAL - DEMOLITION - BUILDING 1 - B LEVEL

MD-1-A-01 MECHANICAL - DEMOLITION - BUILDING 1 - A LEVEL

MD-1-3-01 MECHANICAL - DEMOLITION - BUILDING 1 - 3RD FLOOR CORE

MD-1-PH-01 MECHANICAL - DEMOLITION - BUILDING 1 - PENTHOUSE A

MD-7-R-01 MECHANICAL - DEMOLITION - BUILDING 7 - ROOF

MH-1-C-01 MECHANICAL - NEW WORK - BUILDING 1 - C LEVEL

MH-1-C-02 MECHANICAL - NEW WORK - BUILDING 1 - C LEVEL

MH-1-B-01 MECHANICAL - NEW WORK - BUILDING 1 - B LEVEL

MH-1-B-02 MECHANICAL - NEW WORK - BUILDING 1 - B LEVEL

MH-1-B-03 MECHANICAL - NEW WORK - BUILDING 1 - B LEVEL

MH-1-A-01 MECHANICAL - NEW WORK - BUILDING 1 - A LEVEL

MH-1-3-01 MECHANICAL - NEW WORK - BUILDING 1 - 3RD FLOOR CORE

MH-1-PH-01 MECHANICAL - NEW WORK - BUILDING 1 - PENTHOUSE A

MH-7-R-01 MECHANICAL - NEW WORK - BUILDING 7 - ROOF

PLUMBING

PS-001 PLUMBING - SYMBOLS, NOTES & DRAWING INDEX

PS-002 PLUMBING - DETAILS

PD-1-C-01 PLUMBING - DEMOLITION - BUILDING 1 - C LEVEL

PS-1-C-01 PLUMBING - NEW WORK - BUILDING 1 - C LEVEL

SHEET INDEX

DRAWING TITLE

GENERAL

G-001 COVER SHEET

ELECTRICAL

ES-001 ELECTRICAL - SYMBOLS, NOTES & DRAWING INDEX

ES-002 ELECTRICAL - DETAILS

ES-003 ELECTRICAL - PANEL SCHEDULES

ES-004 ELECTRICAL - PANEL SCHEDULES

ES-006 ELECTRICAL - PANEL SCHEDULES

ES-005 ELECTRICAL - PANEL SCHEDULES

ED-1-C-01 ELECTRICAL - DEMOLITION - BUILDING 1 - C LEVEL

ED-1-C-02 ELECTRICAL - DEMOLITION - BUILDING 1 - C LEVEL

ED-1-B-01 ELECTRICAL - DEMOLITION - BUILDING 1 - B LEVEL

ED-1-B-02 ELECTRICAL - DEMOLITION - BUILDING 1 - B LEVEL

ED-1-A-01 ELECTRICAL - DEMOLITION - BUILDING 1 - A LEVEL

ED-1-3-01 ELECTRICAL - DEMOLITION - BUILDING 1 - 3RD FLOOR CORE

ED-1-PH-01 ELECTRICAL - DEMOLITION - BUILDING 1 - PENTHOUSE A

ED-7-R-01 ELECTRICAL - DEMOLITION - BUILDING 7 - ROOF

EP-1-C-01 ELECTRICAL - NEW WORK - BUILDING 1 - C LEVEL

EP-1-C-02 ELECTRICAL - NEW WORK - BUILDING 1 - C LEVEL

EP-1-B-01 ELECTRICAL - NEW WORK - BUILDING 1 - B LEVEL

EP-1-B-02 ELECTRICAL - NEW WORK - BUILDING 1 - B LEVEL

EP-1-A-01 ELECTRICAL - NEW WORK - BUILDING 1 - A LEVEL

EP-1-3-01 ELECTRICAL - NEW WORK - BUILDING 1 - 3RD FLOOR CORE

EP-1-PH-01 ELECTRICAL - NEW WORK - BUILDING 1 - PENTHOUSE A

EP-7-R-01 ELECTRICAL - NEW WORK - BUILDING 7 - ROOF

EQUIPMENT

QF-1-3-01 EQUIPMENT FOOD SERVICE - BUILDING 1 - 3RD FLOOR CORE

FIRE PROTECTION

FA-001 FIRE ALARM - SYMBOLS, NOTES & DRAWING INDEX

FA-002 FIRE ALARM - DETAILS

FA-003 FIRE ALARM - FIRESTOP DETAILS

FAD-1-C-01 FIRE ALARM - DEMOLITION - BUILDING 1 - C LEVEL

FAD-1-C-02 FIRE ALARM - DEMOLITION - BUILDING 1 - C LEVEL

FAD-1-B-01 FIRE ALARM - DEMOLITION - BUILDING 1 - B LEVEL

FAD-1-A-01 FIRE ALARM - DEMOLITION - BUILDING 1 - A LEVEL

FAD-1-3-01 FIRE ALARM - DEMOLITION - BUILDING 1 - 3RD FLOOR CORE

FAD-1-PH-01 FIRE ALARM - DEMOLITION - BUILDING 1 - PENTHOUSE A

FAD-7-R-01 FIRE ALARM - DEMOLITION - BUILDING 7 - ROOF

FA-1-C-01 FIRE ALARM - NEW WORK - BUILDING 1 - C LEVEL

FA-1-C-02 FIRE ALARM - NEW WORK - BUILDING 1 - C LEVEL

FA-1-B-01 FIRE ALARM - NEW WORK - BUILDING 1 - B LEVEL

FA-1-A-01 FIRE ALARM - NEW WORK - BUILDING 1 - A LEVEL

FA-1-3-01 FIRE ALARM - NEW WORK - BUILDING 1 - 3RD FLOOR CORE

FA-1-PH-01 FIRE ALARM - NEW WORK - BUILDING 1 - PENTHOUSE A

FA-7-R-01 FIRE ALARM - NEW WORK - BUILDING 7 - ROOF

FX-001 FIRE SUPPRESSION - SYMBOLS, NOTES & DRAWING INDEX

FX-002 FIRE SUPPRESSION - DETAILS

FX-003 FIRE SUPPRESSION - FIRESTOP DETAILS

FXD-1-C-01 FIRE SUPPRESSION - DEMOLITOIN - BUILDING 1 - C LEVEL

FXD-1-B-02 FIRE SUPPRESSION - DEMOLITION - BUILDING 1 - B LEVEL

FXD-1-A-01 FIRE SUPPRESSION - DEMOLITION - BUILDING 1 - A LEVEL

FXD-1-3-01 FIRE SUPPRESSION - DEMOLITION - BUILDING 1 - 3RD FLOOR CORE

FXD-1-PH-01 FIRE SUPPRESSION - DEMOLITION - BUILDING 1 - PENTHOUSE A

FX-1-C-01 FIRE SUPPRESION - NEW WORK - BUILDING 1 - C LEVEL

FX-1-B-02 FIRE SUPPRESSION - NEW WORK - BUILDING 1 - B LEVEL

FX-1-A-01 FIRE SUPPRESSION - NEW WORK - BUILDING 1 - A LEVEL

FX-1-3-01 FIRE SUPPRESSION - NEW WORK - BUILDING 1 - 3RD FLOOR CORE

FX-1-PH-01 FIRE SUPPRESSION - NEW WORK - BUILDING 1 - PENTHOUSE A

Revisions: Date:

PB

K

( NOTE: SYMBOLS WITHIN THIS SCHEDULE ARE REPRESENTATIVE OF THOSE TYPICALLY FOUND ON THE DRAWINGS. ALL SYMBOLS MAY NOT APPEAR ON THIS SET OF DRAWINGS. )ELECTRICAL SYMBOLS

DIMENSION INDICATES HEIGHT, AFF, AT WHICH DEVICE IS TO BE MOUNTED.

ON CENTER.

ABOVE FINISHED FLOOR TO CENTERLINE OF DEVICE.

TELEPHONE TERMINAL BOARD.

EMPTY CONDUIT.

ABBREVIATIONS

AFF

EC

OC

TTB

+60"

NIGHT LIGHTING, 24 HOUR, OPERATION. WIRE AHEAD OF ALL LOCAL SWITCHES.NL

TELEPHONE OUTLET, FLUSH FLOOR MOUNTED.

TELEPHONE OUTLET, WALL MOUNTED 18" AFF TO CENTER OF DEVICE.

SECURITY SYSTEM CLOSED CIRCUIT T.V. CAMERA. SUBSCRIPT INDICATES PAN/TILT/ZOOM CONTROL.

SECURITY SYSTEM PUSHBUTTON STATION. SURFACE MOUNTED 42" AFF.

PUBLIC ADDRESS SYSTEM MICROPHONE OUTLET, WALL MOUNTED 18" AFF. COORDINATE TYPE OF

PUBLIC ADDRESS SYSTEM HORN, WALL MOUNTED 7'-6" AFF. UNLESS OTHERWISE INDICATED.

PUBLIC ADDRESS SYSTEM SPEAKER, CEILING MOUNTED.

OUTLET WITH OWNER'S EQUIPMENT.

W = WALL MOUNTED STATION

INTERCOM OUTLET WALL MOUNTED 42" AFF TO CENTER OF DEVICE, WITH DESK MOUNTED STATION UNLESS

INTERCOM WALL MOUNTED 18" AFF TO CENTER OF DEVICE, WITH DESK MOUNTED STATION.

VOICE/DATA OUTLET, WALL MOUNTED 18" AFF TO CENTER OF DEVICE. PROVIDE 3/4"C. FROM

MODIFIERS FOR INTERCOM:

S = SUB STATION

M = MASTER STATION

TELEPHONE OUTLET, WALL MOUNTED 48" AFF.

VOICE/DATA OUTLET, WALL MOUNTED 42" AFF, 2" FROM BOTTOM OF OUTLET TO BACKSPLASH.

PROVIDE 3/4"C. FROM OUTLET TO AN ACCESSIBLE SPACE ABOVE THE CORRIDOR LAY-IN CEILING.

OR 6" FROM BOTTOM OF OUTLET TO COUNTERTOP.

TELEPHONE OUTLET WALL MOUNTED 42" AFF, 2" FROM BOTTOM OF OUTLET TO BACKSPLASH,

PROVIDE FLUSH MOUNTED JUNCTION BOX WITH APPROPRIATE COVERPLATE. PROVIDE 1 1/4" EMPTY CONDUIT WITH NYLON PULL CORD FROM JUNCTION BOX TO ABOVE ACCESSIBLE CEILING FOR VOICE/DATA WIRING TO

PRE WIRED FURNITURE. COORDINATE EXACT REQUIREMENTS AND LOCATION WITH EQUIPMENT

MODIFIERS FOR VOICE/DATA & TELEPHONE OUTLETS: (DEVICE AND CONDUCTORS BY TELECOM VENDOR) a = VOICE ONLY b = STANDARD (2 DATA / 1 VOICE SPLIT) c = 1 DATA ONLY d = 4 DATA / 1 VOICE SPLIT

COMMUNICATIONS

VOICE/DATA OUTLET, FLUSH FLOOR MOUNTED.

GROUND BAR - 1/8"x1"x12" COPPER BUS IN NEMA 1 ENCLOSURE. LOCATE ABOVE SUSPENDED CEILING.

PUBLIC ADDRESS SYSTEM VOLUME CONTROL SWITCH, WALL MOUNTED 42" AFF.

CONDUIT SLEEVES. SEE PLANS FOR SIZE AND QUANTITY.

W

LED LIGHTING FIXTURE, WALL MOUNTED OR UNDER CABINET, CONNECTED TO NORMAL POWER.

LED LIGHTING FIXTURE, CEILING OR WALL MOUNTED,

POLE MOUNTED LIGHTING FIXTURE. SEE SCHEDULE FOR TYPE (*).

DRAWINGS. SEE SCHEDULE FOR TYPE (*).

CEILING OR WALL MOUNTED EXIT SIGN. PROVIDE NUMBER OF FACES AND CHEVRONS AS INDICATED ON

EMERGENCY LIGHTING FIXTURE, CEILING-MOUNTED OR WALL-MOUNTED AT 7'-6" AFF UNLESS NOTED

OTHERWISE. CONNECT UNSWITCHED.

LIGHTING

LED LIGHTING WALLWASH FIXTURE, CEILING MOUNTED.

TRACK LIGHTING FIXTURE. SEE PLANS/SCHEDULE FOR TRACK LENGTH AND NUMBER OF TRACK HEADS.

EQUIPMENT IDENTIFICATION

HORSEPOWER RATING

MOTOR CONNECTION. SPECIAL VOLTAGES AS SHOWN ON DRAWING.

ENCLOSED CIRCUIT BREAKER. NUMERAL INDICATES TRIP AMPERE RATING.

FUSED SAFETY SWITCH. NUMERAL INDICATES FUSE RATING.

NON-FUSIBLE SAFETY SWITCH. NUMERAL INDICATES AMPERE RATING.

SIZE AND BOTTOM NUMERAL INDICATES NEMA STARTER SIZE.

COMBINATION MOTOR STARTER WITH CIRCUIT BREAKER. TOP NUMERAL INDICATES CIRCUIT BREAKER

MOTOR STARTER. NUMERAL INDICATES NEMA SIZE.

AMPACITY. SEE FEEDER SCHEDULE.

ON RISERS, DESIGNATION DENOTES QUANTITY OF CURRENT CARRYING CONDUCTORS AND FEEDER

WIRING SYSTEM CONCEALED IN OR ABOVE CEILING OR IN WALL.

WIRING SYSTEM BELOW FLOOR OR BELOW GRADE.

DESIGNATION DENOTES PANEL BOARD, SWITCHBOARD, MOTOR CONTROL CENTER, ETC., AND OVERCURRENT BRANCH OR FEEDER CIRCUIT HOMERUN TO PANEL BOARD, SWITCHBOARD, MOTOR CONTROL CENTER, ETC.

WIRING SYSTEM TURNED UP.

WIRING SYSTEM TURNED DOWN.

WIRING SYSTEM EXPOSED.

PROTECTION DEVICE NUMBER.

DRY TYPE TRANSFORMER.

NEC REQUIRED GROUND.

EF-1, 10 HP.460V, 3∅

208V, 3∅

120V, 1∅

MOTOR RATED SWITCH.

CONNECTION TO WALL MOUNTED FILM ILLUMINATOR. PROVIDE RECEPTACLE IN FLUSH OUTLET BOX AT

LOWER RIGHT HAND CORNER OF UNIT IF SURFACE MOUNTED. HARD WIRE IF RECESSED.

JUNCTION BOX AND CONNECTION TO EQUIPMENT OR TERMINAL STRIPS.

CEILING FAN 120V. MANUFACTURER (HUNTER#21252 GREEN FINISH W/ INTEGRATED 240W LIGHT FIXTURE)

CONNECTION TO HEADWALL UNIT. ONE NORMAL POWER CIRCUIT. ONE CRITICAL POWER CIRCUIT, CONNECTION TO FAN COIL UNIT. COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR.

AND ONE DEDICATED CRITICAL POWER CIRCUIT FOR VENTILATOR.

CONNECTION TO EXHAUST FAN. COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR.

PANELBOARD SURFACE MOUNTED.

REMOTE ALARM PANEL FOR ISOLATED POWER PANEL BOARD WALL MOUNTED AT 5'-0" AFF.

GENERATOR REMOTE ALARM ANNUNCIATOR. WALL MOUNTED AT 5'-0" AFF.

N = NORMAL BRANCH

U = UNGROUNDED (ISOLATION) PANEL

Q = EQUIPMENT BRANCH

C = CRITICAL BRANCH

L = LIFE SAFETY BRANCH

M = MOTOR CONTROL CENTER

L = 120/208 VOLT

H = 277/480 VOLT

PANELBOARD FLUSH MOUNTED.

1,2,3 = FLOOR

A,B,C = LOCATION

PANELBOARD NAMING CONVENTION

JUNCTION OR PULL BOX. W = WEATHERPROOF.

CONDUIT STUBBED INTO ACCESSIBLE CEILING SPACE.

HARDWIRE CONNECTION FROM FLUSH MOUNTED JUNCTION BOX WITH APPROPRIATE COVERPLATE AND 3/4" LIQUID TIGHT FLEXIBLE METALLIC WHIP TO PRE-WIRED FURNITURE. COORDINATE EXACT REQUIREMENTS AND LOCATION WITH EQUIPMENT SUPPLIER/INSTALLER. EIGHT(8) WIRE SYSTEM PROVIDES FOUR(4) CIRCUITS.

POWER

SURFACE MOUNTED MULTIOUTLET ASSEMBLY. 46" AFF OR 8" ABOVE COUNTER

TV = TELEVISION, SEE DETAIL.

G = GROUND FAULT CIRCUIT INTERRUPTER.

EWC = ELECTRIC WATER COOLER POWER CONNECTION, PROVIDE GROUND FAULT CIRCUIT INTERRUPTER

P = PEDESTAL

WP = WEATHERPROOF "IN-USE" COVER, PROVIDE GROUND FAULT CIRCUIT INTERRUPTER DEVICE.

DUPLEX RECEPTACLE, MOUNTED 18" AFF TO CENTER OF DEVICE. NEMA 5-20R UNLESS OTHERWISE

OR 2" ABOVE BACKSPLASH. SHADED AREA INDICATES RECEPTACLE.

DUPLEX RECEPTACLE OUTLET. FLUSH FLOOR MOUNTED.

SIMPLEX RECEPTACLE MOUNTED 18" AFF TO CENTER OF DEVICE. NEMA 5-20R UNLESS OTHERWISE

TWO DUPLEX RECEPTACLES IN 2-GANG BOX, MOUNTED 42" AFF TO CENTER OF OUTLET

OR 2" FROM BOTTOM OF OUTLET TO TOP OF BACKSPLASH OR COUNTERTOP. SLASH INDICATES

OUTLET TO TOP OF BACKSPLASH OR COUNTERTOP. SLASH INDICATES CONNECTED TO THE EMERGENCY

DUPLEX RECEPTACLE, MOUNTED 42" AFF TO CENTER OF OUTLET OR 2" FROM BOTTOM OF

TWO DUPLEX RECEPTACLES IN 2-GANG BOX, MOUNTED 18" AFF TO CENTER OF DEVICE. SLASH

DUPLEX RECEPTACLE OUTLET. CEILING MOUNTED.

SPECIAL RECEPTACLE OUTLET. NEMA CONFIGURATION AS INDICATED.

MODIFIERS FOR RECEPTACLES:

SPECIAL RECEPTACLE OUTLET. FLUSH FLOOR MOUNTED. NEMA CONFIGURATION AS INDICATED.

LH2A-1

CH2A

POWER POLE. DEVICE CONFIGURATION AND COLOR AS INDICATED.

EQUIPMENT CONNECTION DESIGNATION, SEE SCHEDULE FOR DETAILS.

M

RATING AND BOTTOM NUMERAL INDICATES NEMA STARTER SIZE.

COMBINATION MOTOR STARTER WITH FUSED SWITCH. TOP NUMERAL INDICATES FUSETRON AMPERE

LIGHTNING PROTECTION SYSTEM GROUND ROD.

75KVA

T

LIGHTNING PROTECTION SYSTEM AIR TERMINAL.

TR = TAMPER RESISTANT

3 = THREE WAY

MODIFIERS FOR SWITCHES:

SINGLE POLE SWITCH, MOUNTED 42" AFF TO CENTER OF DEVICE.

THREE SINGLE POLE SWITCHES IN A 3-GANG BOX, MOUNTED 42" AFF TO CENTER OF DEVICE.

PHOTO ELECTRIC CELL MOUNTED ON CONDUIT STUBBED 6" ABOVE ROOF, FACING NORTH.

SWITCHES

TWO SINGLE POLE SWITCHES IN A 2-GANG BOX, MOUNTED 42" AFF TO CENTER OF DEVICE.

PROVIDE DIVIDER FOR DIFFERENT VOLTAGES OR BRANCHES.

4 = FOUR WAY

D = DIMMER

DT = DOUBLE THROW

LV = LOW VOLTAGE

TWO SINGLE POLE SWITCHES IN A 2-GANG BOX, MOUNTED 42" AFF TO CENTER OF DEVICE, TO COMPLY WITH ENERGY CODE. EITHER SWITCH INBOARD AND OUTBOARD LAMPS SEPARATELY OR STEP-DIM BOTH

PROVIDE DIVIDER(S) FOR DIFFERENT VOLTAGES OR BRANCHES.

OS = OCCUPANCY SENSOR

TIME CLOCK. PROVIDE POWER CIRCUIT AND 3/4" CONDUIT TO ACCESSIBLE CEILING SPACE.

a,b,c = MULTIPLE SWITCH LEGS

T = TIMER

INDICATED.

INDICATED. SLASH INDICATES CONNECTED TO THE EMERGENCY POWER SYSTEM.

INDICATES CONNECTED TO THE EMERGENCY POWER SYSTEM.

CONNECTED TO NORMAL POWER. SEE SCHEDULE FOR TYPE (*). SEE ARCHITECTURAL RCP FOR EXACT

LUMINAIRE, CEILING MOUNTED, CONNECTED TO THE NORMAL POWER SYSTEM (UNLESS OTHERWISE NOTED).

SEE SCHEDULE FOR TYPE (*). SEE ARCHITECTURAL RCP FOR EXACT LOCATION AND CEILING TYPE.

LOCATION AND CEILING TYPE. SLASH INDICATES CONNECTED TO THE CRITICAL BRANCH.

SEE SCHEDULE FOR TYPE (*).

SEE SCHEDULE FOR TYPE (*).

REMOTE EMERGENCY EGRESS TWIN-LAMP UNIT.

HALF-SHADED INDICATES CONNECTED TO LIFE SAFETY BRANCH.

LAMPS TO 50%.

NOTED OTHERWISE.

SUPPLIER/INSTALLER.

PTZ

SLASH INDICATES CONNECTED TO THE CRITICAL BRANCH. HALF-SHADED INDICATES CONNECTED TO THE EMERGENCY OR LIFE SAFETY BRANCH; VIA EMERGENCY GENERATOR SET OR BATTERY BALLAST, SEE PLANS.

SLASH INDICATES CONNECTED TO THE CRITICAL BRANCH. SEE SCHEDULE FOR TYPE (*).

HEADWALL. SEE PLAN FOR NUMBER.HW#

POWER COLUMN. SEE PLAN FOR NUMBER.PC#

OUTLET TO AN ACCESSIBLE SPACE ABOVE THE CORRIDOR LAY-IN CEILING.

POWER SYSTEM.

CONNECTED TO THE EMERGENCY POWER SYSTEM.

LED STRIP LUMINAIRE. CEILING MOUNTED OR SUSPENDED 8'-0" AFF TO BOTTOM OF LUMINAIRE, CONNECTED TO NORMAL POWER. SLASH INDICATES CONNECTED TO THE CRITICAL BRANCH.

HALF-SHADED INDICATES CONNECTED TO THE EMERGENCY OR LIFE SAFETY BRANCH; VIA EMERGENCY

GENERATOR SET OR BATTERY BALLAST, SEE PLANS.

CARD READER. PROVIDE BOX AND CONDUIT AS REQUIRED. COORDINATE WITH HARDWARE VENDOR.

ELECTRIC STRIKE. PROVIDE BOX AND CONDUIT AS REQUIRED. COORDINATE WITH HARDWARE VENDOR.

WALL MOUNTED LOCAL ALARM BUZZER, 85dBA.

PUSH BUTTON DOOR RELEASE WITH SOUNDER COVER.

MAGNETIC LOCK FOR DOOR.

D

PUBLIC ADDRESS SYSTEM SPEAKER, CEILING MOUNTED.

REMOTE LINE ISOLATION MONITOR.

CABLE TV OUTLET, MOUNTED ADJACENT TO TV RECEPTACLE, UNLESS NOTED OTHERWISE.

PUSHPAD. PROVIDE BOX AND CONDUIT AS REQUIRED. COORDINATE WITH HARDWARE VENDOR.

VARIABLE SPEED DRIVEVSD

EXPEDITOR SYSTEM

WIRELESS TELEMETRY ANTENNA

WIRELESS TELEMETRY DEVICE

EXPEDITER BUTTON PANEL

EXAM LIGHT CONTROLLER

EMERGENCY EGRESS PUSH BUTTON

KEY PAD CARD READER

EMERGENCY RELEASE SWITCH. PROVIDE TAMPER RESISTANT COVER WITH A SOUNDING HORN.

PNEUMATIC TUBE STATIONPTS

BUTTON RELEASE.

BADGE ACCESS.

NURSE LOCATOR.

EMERGENCY MANUAL OVERRIDE.

DEVICE. INSTALL DEVICE SO IT IS CONCEALED BEHIND ENCLOSURE, COORDINATE WITH PLUMBING.

SHOWN TO CLARIFY THAT DEVICES/LUMINAIRES ON THE SAME CIRCUIT ARE CONTROLLED SEPARATELY.

POLE MOUNTED LIGHTING FIXTURE. SEE SCHEDULE FOR TYPE (*).

SYMBOL LOCATION LEADER

4/350

XXXX

ERS

GENERAL PROJECT NOTES

1. THE DRAWINGS SHALL NOT BE SCALED FOR CONSTRUCTION PURPOSES.

THE SCALE WHEN INDICATED IS INTENDED FOR GENERAL REFERENCE

ONLY.

2. SHUTDOWNS SHALL BE COORDINATED AND APPROVED THROUGH THE

OWNERS' REPRESENTATIVE AND WILL REQUIRE ADVANCE NOTICE OF ONE

WEEK. THIS TIME LENGTH MAY BE LONGER OR SHORTER FOR SOME

SHUTDOWNS AND SHALL BE AT THE OWNER'S DISCRETION.

3. CONSTRUCTION DEBRIS SHALL BE REMOVED DAILY.

4. ALL FIXED ELECTRICAL EQUIPMENT FURNISHED BY ELECTRICAL

CONTRACTOR SHALL BE LISTED AND LABELED BY AN APPROVED TESTING

AGENCY. FACTORY ASSEMBLED LISTED COMPONENTS SHALL BE LISTED

AND LABELED AS AN ASSEMBLY. ANY ELECTRICAL EQUIPMENT NOT

LISTED OR LABELED MUST BE APPROVED BY THE LOCAL AUTHORITY

HAVING JURISDICTION AND HAVE A THIRD PARTY TESTING LABEL.

5. FIRE ALARM APPLIANCES AND DEVICES SHOWN INDICATE TO PROVIDE

COVERAGE IN THAT AREA. ELECTRICAL CONTRACTOR SHALL PROVIDE

APPLIANCES AND DEVICES AS REQUIRED BY THE LATEST EDITION OF

NFPA 72 AND THE BUILDING CODE. NO CHANGE ORDERS WILL BE

ALLOWED FOR APPLIANCES AND DEVICES REQUIRED BY NFPA 72 AND THE

BUILDING CODE.

6. CONTRACTOR SHALL COORDINATE WITH THE FACILITY'S INFECTION

CONTROL OFFICER TO VERIFY THAT APPROPRIATE SAFEGUARDS ARE

BEING TAKEN TO PROTECT WORKERS INVOLVED IN DEMOLITION

ACTIVITIES.

7. CONTRACTOR SHALL COORDINATE WITH FACILITY'S INFECTION CONTROL

OFFICER TO VERIFY THAT APPROPRIATE PRECAUTIONS ARE BEING TAKEN

TO PROTECT FACILITY STAFF AND PATIENTS DURING THE CONSTRUCTION

ACTIVITIES.

8. ASBESTOS CONTAINING MATERIALS (IF PRESENT) WILL BE IDENTIFIED BY

THE OWNER AND WILL BE REMOVED FROM AHU'S, PIPING INSULATION,

DUCT INSULATION, ETC. (IF REQUIRED) PRIOR TO CONTRACTOR BEGINNING

ANY WORK ON THE SITE. COORDINATE WITH OWNER.

9. COMPLETE EXISTING ELECTRICAL WORK AS INDICATED ON THE PLANS.

CONNECTIONS OF FEEDERS AND BRANCH CIRCUITS TO NEW PANELS

SHALL BE DONE TO KEEP DOWNTIME TO AN ABSOLUTE MINIMUM.

10. ALL TERMINATIONS, CONDUCTORS, AND DEVICES SHALL BE 75 DEGREE

RATED.

LIM

RA

GA

J

E

C

M

H

F

P

P

S

P

J

SS

SS

ELC

EXIT

KPCR

PP

ES

CR

ES

AL

PB

ML

BR

BA

NL

EMO

SS

V

M

H

GB

P S

P S

C

TC

PE

SS

SSS

SS

S

DUAL TECHNOLOGY CEILING MOUNTED OCCUPANCY SENSOR. PROVIDE ONE POWER PACK FOR EACHOS

SENSOR. COORDINATE WIRING REQUIREMENTS WITH EQUIPMENT SUPPLIER PRIOR TO ROUGH-IN.

WIRELESS ACCESS POINTWAP

DEMOLITION NOTES

A.

B.

C.

D.

E.

F.

G.

H.

I.

COORDINATE ALL DEMOLITION WORK WITH OWNER PRIOR TO BEGINNING WORK.

REMOVE ALL ELECTRICAL DEVICES, WIRING AND RACEWAYS IN WALLS AND CEILINGS BEING DEMOLISHED UNLESS NOTED OTHERWISE. RECONNECT DEVICES AND FIXTURES DOWNSTREAM OF REMOVED WORK.

UNLESS OTHERWISE NOTED, WIRING AND RACEWAYS ARE TO BE REMOVED BACK TO THEIR SOURCE.

RELOCATE EXISTING WORK TO REMAIN WHICH INTERFERES WITH RENOVATION.

ELECTRICAL DEMOLITION WORK SHALL BE PHASED IN ACCORDANCE WITH PROJECT "GENERAL

CONDITIONS". ELECTRICAL CONTRACTOR SHALL DEVELOP A PHASING SCHEME WHICH WILL WORK WITH

THE ARCHITECT'S OVERALL PHASING PLAN AND WITH WORK TO BE DONE BY OTHER TRADES.

CONTRACTOR SHALL PROVIDE TEMPORARY POWER WHERE NECESSARY AT NO EXTRA COST TO THE

OWNER IN ORDER TO KEEP THE BUILDING IN OPERATION DURING EACH PHASE OF THE RENOVATION.

REMOVE EXISTING ELECTRICAL WORK AS INDICATED. TRANSFER OF FEEDERS AND BRANCH CIRCUITS TO NEW PANELS SHALL BE DONE IN A MANNER THAT WILL KEEP DOWNTIME TO AN ABSOLUTE MINIMUM.

ALL OUTAGES SHALL BE COORDINATED WITH OWNER AT LEAST 72 HOURS IN ADVANCE. OUTAGES WHICH ARE ANTICIPATED TO LAST LONGER THAN 1 HOUR SHALL BE COORDINATED WITH OWNER AT LEAST 1

WEEK IN ADVANCE.

ELECTRICAL CONTRACTOR SHALL REMOVE ALL ELECTRICAL WORK ASSOCIATED WITH WORK INDICATED TO BE REMOVED ON THE ARCHITECTURAL, PLUMBING, MECHANICAL AND FIRE PROTECTION DRAWINGS.

ELECTRICAL WORK SHOWN IS BASED ON FIELD OBSERVATIONS AND EXISTING DRAWINGS AND IS

PROVIDED TO CONVEY THE GENERAL SCOPE OF DEMOLITION WORK TO BE ACCOMPLISHED. THE

ELECTRICAL CONTRACTOR SHALL VISIT THE SITE AND OBSERVE EXISTING CONDITIONS PRIOR TO BIDDING.

RL = EXISTING DEVICE TO BE RELOCATED.

DASHED SYMBOLS INDICATE EXISTING DEVICES.

RLD = RELOCATED DEVICE SHOWN IN FINAL LOCATION.

RM = EXISTING DEVICE TO REMAIN.

RM

RM

RV = EXISTING DEVICE TO BE REMOVED.

RP = EXISTING DEVICE TO BE REPLACED WITH NEW DEVICE.

EX = EXISTING DEVICE

11. ELECTRICAL CONTRACTOR IS NOT PERMITTED TO ROUTE WIRING

CONNECTED TO THE LIFE SAFETY OR CRITICAL BRANCH SOURCES OF

POWER IN FLEXIBLE METAL RACEWAYS OR METAL SHEATHED CABLE

ASSEMBLIES, WITH THE EXCEPTIONS OF THE EXEMPTIONS LISTED IN NEC

517.30.C.3.

12. ELECTRICAL CONTRACTORS SHALL PROVIDE SEPARATE RACEWAY,

JUNCTION BOXES OR CABINETS THAT ROUTE LIFE SAFETY AND/OR CRITICAL

BRANCH CIRCUITS WIRING FROM ALL WIRING AND EQUIPMENT CONNECTED

TO OTHER BRANCHES OF POWER.

13. UNLESS NOTED OTHERWISE, ELECTRICAL CONTRACTOR SHALL INSTALL ALL

RACEWAY, BOXES, AND CABLES. ALL MEDICAL EQUIPMENT CABLES, UNLESS

OTHERWISE NOTED, SHALL BE PROVIDED BY MEDICAL EQUIPMENT VENDOR.

14. ALL ELECTRICAL WORK MUST BE COMPLETED IN PHASES, AS ESTABLISHED

IN "GENERAL CONDITIONS".

15.

16.

A MAXIMUM OF THREE 20A, 1 POLE BRANCH CIRCUITS MAY BE COMBINED IN

A COMMON HOMERUN SHARING A COMMON NEUTRAL OR WITH SEPARATE

NEUTRALS, FOR A TOTAL OF SIX CURRENT CARRYING CONDUCTORS. ALL

BRANCH CIRCUITS LARGER THAN 20A SHALL BE SEPARATELY HOMERUN TO

PANEL.

17.

CONDUCTORS SHALL BE COPPER, RATED AT NOT LESS THAN 600 VOLTS.

MINIMUM SIZE SHALL BE NO. 12 AWG UNLESS OTHERWISE NOTED ON THE

DRAWINGS. ALL WIRE #8 AWG AND LARGER SHALL BE STRANDED. #10 THRU

#12 AWG CONDUCTORS SHALL BE SOLID. ALL INSULATION TYPES SHALL BE

THWN OR THHN.

18.

ELECTRICAL CONTRACTOR SHALL USE MULTI-POLE BREAKERS FOR ALL

SHARED NEUTRALS OR PROVIDE SEPARATE NEUTRALS FOR EACH BRANCH

CIRCUIT. ADJUST PANEL SCHEDULES ACCORDINGLY TO MEET NEC 210.4.

19.

ALL WORK ASSOCIATED WITH VOICE, DATA, CCTV, CATV, NURSE CALL, WI-FI,

PUBLIC ADDRESS, SECURITY ACCESS, TO BE PROVIDED BY THE OWNER. THE

CONTRACTOR TO PROVIDE BACK BOXES, CONDUIT STUB-UP AND PULL

WIRE.

20.

BRANCH CIRCUIT WIRE SIZING WILL BE IN ACCORD WITH THE FOLLOWING

TABLES:

REMAINDER

VOLTS DISTANCE HOMERUN OF CIRCUIT

120/208 0' - 50' #12 #12

50' - 100' #10 #12

100 - 150' #8 #10

21.

A SHORT-CIRCUIT/ARC FLASH AND SELECTIVE COORDINATION STUDY

SHALL BE PREPARED FOR THE ELECTRICAL OVERCURRENT DEVICES TO BE

INSTALLED UNDER THIS PROJECT. FINAL FIELD SETTINGS AND

MODIFICATIONS OF THE OVERCURRENT PROTECTIVE DEVICES SHALL BE

MADE TO CONFIRM WITH THE STUDY, WITHOUT ADDITIONAL COST TO THE

OWNER.

ALL BREAKERS 600 AMP AND ABOVE ARE TO BE SOLID-STATE TYPE. SELECT

ELECTRONIC TRIP FUNCTIONS FOR LOW-VOLTAGE CIRCUIT BREAKERS SO

AS TO ACHIEVE SELECTIVE COORDINATION.

REMAINDER

VOLTS DISTANCE HOMERUN OF CIRCUIT

277/480 0' - 125' #12 #12 125' - 220' #10 #12

220 - 330' #8 #10

ELECTRICAL ENERGY CODE SUMMARY

ELECTRICAL SUMMARY

ELECTRICAL SYSTEM AND EQUIPMENT

Method of Compliance:

Prescriptive Performance

Lighting schedule lamp type required in fixture number of lamps in fixture ballast type used in the fixture number of ballasts in fixture total wattage per fixture total interior wattage specified vs. allowed NO ADDITIONAL LIGHTING LOAD ADDED total exterior wattage specified vs. allowed N/A

Additional Efficiency Package Options

C406.2 More Efficient HVAC Equipment Performance

C406.3 Reduced Lighting Power Density

C406.4 Enhanced Digital Lighting Controls

C406.5 On-Site Renewable Energy

C406.6 Dedicated Outdoor Air System

Energy Code:

ASHRAE 90.1: Prescriptive Performance

C406.7 Reduced Energy Use in Service Water Heating

(When using the 2018 NCECC; not required for ASHRAE 90.1)

COMMUNICATIONS

FIRE ALARM

POWER AND FIRE ALARM CONNECTION TO

SMOKE DAMPER OR FIRE/SMOKE DAMPER,

SEE DETAIL ON ES-002.

FSD

FIRE ALARM SMOKE DETECTOR.S

D

FIRE ALARM DUCT MOUNTED SMOKE DETECTOR.D

D

POWER CONNECTION TO FIRE DAMPER.F

D

HEAT DETECTORH

D

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT STAMPPROGRAM MANAGER

321 4 5 6 7 8 9 10

ENGINEER OF RECORD

Charlotte Engineers, LLP 5838 Monroe Road Charlotte, NC 28212 704-531-3000 Michael Eaves

M L o c a l R e v it F ile s \R e v it

\4

C

E C e n tr a l M o d e l.

rv t

/1

/2

:1

:2

P

M

ES-001

ELECTRICAL - SYMBOLS, NOTES &

DRAWING INDEX

VAMC EAST ORANGE AHU &

WATER-COOLED EQUIPMENT

UPGRADES

EAST ORANGE, NEW JERSEY

561-19-130

3/11/2021 CLH JMM

FULLY SPRINKLERED

ELECTRICAL - DRAWING INDEX

Sheet Number Sheet Name

ES-001 ELECTRICAL - SYMBOLS, NOTES & DRAWING INDEX

ES-002 ELECTRICAL - DETAILS

ES-003 ELECTRICAL - PANEL SCHEDULES

ES-004 ELECTRICAL - PANEL SCHEDULES

ES-006 ELECTRICAL - PANEL SCHEDULES

ES-005 ELECTRICAL - PANEL SCHEDULES

ED-1-C-01 ELECTRICAL - DEMOLITION - BUILDING 1 - C LEVEL

ED-1-C-02 ELECTRICAL - DEMOLITION - BUILDING 1 - C LEVEL

ED-1-B-01 ELECTRICAL - DEMOLITION - BUILDING 1 - B LEVEL

ED-1-B-02 ELECTRICAL - DEMOLITION - BUILDING 1 - B LEVEL

ED-1-A-01 ELECTRICAL - DEMOLITION - BUILDING 1 - A LEVEL

ED-1-3-01 ELECTRICAL - DEMOLITION - BUILDING 1 - 3RD FLOOR CORE

ED-1-PH-01 ELECTRICAL - DEMOLITION - BUILDING 1 - PENTHOUSE A

ED-7-R-01 ELECTRICAL - DEMOLITION - BUILDING 7 - ROOF

EP-1-C-01 ELECTRICAL - NEW WORK - BUILDING 1 - C LEVEL

EP-1-C-02 ELECTRICAL - NEW WORK - BUILDING 1 - C LEVEL

EP-1-B-01 ELECTRICAL - NEW WORK - BUILDING 1 - B LEVEL

EP-1-B-02 ELECTRICAL - NEW WORK - BUILDING 1 - B LEVEL

EP-1-A-01 ELECTRICAL - NEW WORK - BUILDING 1 - A LEVEL

EP-1-3-01 ELECTRICAL - NEW WORK - BUILDING 1 - 3RD FLOOR CORE

EP-1-PH-01 ELECTRICAL - NEW WORK - BUILDING 1 - PENTHOUSE A

EP-7-R-01 ELECTRICAL - NEW WORK - BUILDING 7 - ROOF

A

A

Section A-A

1. RATED WALL OR FLOOR ASSEMBLY - PROVIDE FIRE STOPPING ASSEMBLY FOR

PARTITION TYPE & RATING ENCOUNTERED.

2. THROUGH PENETRATION - PROVIDE FIRE STOPPING ASSEMBLY FOR SIZE &

MATERIAL OF THROUGH PENETRATION UTILIZED.

3. FIRE STOPPING MATERIAL - PROVIDE FIRE STOPPING MATERIAL FOR WALL

ASSEMBLY & THROUGH PENETRATION MATERIAL ENCOUNTERED. FILL VOIDS OR

CAVITY ACCORDING TO THE REQUIREMENTS OF THE FIRE STOPPING SYSTEM

UTILIZED.

ALL RATED WALLS, PARTITIONS OR FLOORS SHALL BE PROVIDED WITH A UL LISTED

FIRE STOP SYSTEM. THE SYSTEM UTILIZED SHALL MATCH THE SEPARATION

PENETRATED AND THE THROUGH PENETRATION MATERIAL.

DETAILS FOR THE INSTALLATION OF SYSTEM TYPE UTILIZED SHALL BE AVAILABLE AT

THE PROJECT SITE FOR THE DURATION OF CONSTRUCTION AND SHALL BE PROVIDED

TO THE AUTHORITY HAVING JURISDICTION AND TO THE BUILDING OWNER AT THE

PROJECT COMPLETION.

PROVIDE WALL OR FLOOR LABELS INDICATING THE SYSTEM MANUFACTURER AND UL

LISTED ASSEMBLY NUMBER AT EACH LOCATION WHERE THE FIRE STOPPING SYSTEM

IS INSTALLED.

THROUGH PENETRATION FIRESTOP SYS.

(PROVIDE UL LISTED SYSTEM)

EXIT

12", UNLESS CEILING IS HIGHER

THAN 12'-0", THEN 24" ABOVE DOOR.

CEILING

FLOOR

WALL MOUNTED

TELEPHONE

2" TO

TOP OF

COUNTER OR

BACKSPLASH

18"

RECEPTACLE

LIGHT SWITCH

OR DIMMER

ALIGN WHERE

POSSIBLE

TELEPHONE OR

VOICE DATA OUTLET

TV OUTLET

OR CLOCK

OUTLET

FIRE ALARM DEVICES

A B

O V

E F

L O

O R

T O

B O

T T

O M

O F

D E

V

IC

E

O N

C O

L U

M N

S

MOUNTING HEIGHTS OF DEVICES

FOR WALL MOUNTED UNITS:

BOTTOM

OF DEVICE

N O

T T

O E

X C

E E

D

T O

B O

T T

O M

GENERAL DETAIL NOTES:

A. PARTICULAR ATTENTION SHALL BE GIVEN TO THE ALIGNMENT OF DEVICES.

WHEREVER DEVICES, ON THIS SHEET OR OTHER SHEETS, ARE SHOWN AT

GIVEN LOCATION WITH DIFFERENT MOUNTING HEIGHTS THEY SHALL BE

ALIGNED VERTICALLY. IF THEY ARE SHOWN AT THE SAME MOUNTING HEIGHT

THEY SHALL BE ALIGNED HORIZONTALLY. REFER TO THE ARCHITECTURAL

PLANS, ELEVATIONS AND DETAILS. COORDINATE WITH ARCHITECT PRIOR TO

ROUGH-IN.

B. ALL DIMENSIONS ARE TO THE CENTER LINE OF DEVICE UNLESS INDICATED

OTHERWISE.

C. MOUNTING HEIGHTS SHOWN HERE ARE TYPICAL. PRIOR TO ROUGH-IN,

COORDINATE WITH ARCHITECTURAL PLANS, ELEVATIONS, AND DETAILS. IF A

CONFLICT OCCURS, REQUEST CLARIFICATION FROM ARCHITECT/ENGINEER

PRIOR TO ROUGH-IN.

6"

NTS

NTS

T

N

DEVICE LEGEND:

LIGHT SWITCH

RECEPTACLE

VOICE/DATA OUTLET

NURSE CALL DEVICES

THERMOSTAT

ACOUSTICAL CEILING TILE (TYP)

ARCHITECTURAL

CEILING

GENERAL NOTE:

1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING INSTRUCTIONS AND

USING THE RECOMMENDED MOUNTING HARDWARE.

LUMINAIRE MOUNTING - LAY-IN CEILING

LUMINAIRE

SUSPENSION

WIRES REFER TO

SPECIFICATION

SECTION 26 51 00

3 TWIST MINIMUM

(TYP)

FIXTURE WHIP FROM JUNCTION

BOX (1829mm (6') LONG MAX.)

LUMINAIRE. REFER

TO SCHEDULE

LUMINAIRE MANUFACTURER'S

MOUNTING HARDWARE. REFER TO

SPECIFICATION SECTION 26 51 00

CEILING CROSS

BEAM

LUMINAIRE. REFER TO SCHEDULE

GRID

DEVICE MOUNTING DETAIL

TOP PLATE

STUDS

JUNCTION BOX ABOVE

CEILING MOUNTED ON

BRACKET, TOP PLATE,

OR BY THREADED

ROD FROM STRUCTURE.

HOMERUN

IN EMT.

EMT

CADDY STRAP.

MOUNT TO

STUDS ON BOTH

SIDES.

SWITCH OR

RECEPTACLE.

NAMEPLATE DETAIL

NORMAL

BRANCH

PANEL 'X'

208Y/120V

ENGRAVED THREE-LAYER LAMINATED

PLASTIC WITH ADHESIVE BACKING

PROVIDE ALL ELECTRICAL DISTRIBUTION EQUIPMENT WITH A NAMEPLATE AS

FOLLOWS: (SWITCHBOARDS, PANELBOARDS, BUSWAYS, DISCONNECTS, AHU,

FANS, FCU, ETC)

1/4" LETTERING

(TYPICAL)

WHITE LETTERS ON BLACK BACKGROUND

WHITE LETTERS ON RED BACKGROUND

WHITE LETTERS ON RED BACKGROUND

WHITE LETTERS ON RED BACKGROUND

NORMAL:

LIFE SAFETY:

CRITICAL:

EQUIPMENT:

3/8" LETTERING

GENERAL DETAIL NOTES:

A. PROVIDE SAMPLE FOR APPROVAL BY ENGINEERS/OWNER.

B. COORDINATE NAMING CONVENTION AND DESCRIPTIONS WITH OWNER.

SOURCE

VOLTAGE

BRANCH

NAME OF

EQUIPMENT

OR LOAD

LOCATION

FED FROM PANEL 'MDP'

LOCATED IN F-WING

4TH FLR ELECTRICAL RM

7FCL-37FCL-1

FIRE, SMOKE, & FIRE/SMOKE DAMPER

WIRING DETAIL

NOTES:

1. ALL WIRING SHALL BE INSTALLED IN RACEWAY.

2. MULTIPLE DAMPERS CAN BE SERVED BY EACH JUNCTION BOX UP TO A MAXIMUM OF

10 AMPS PER CIRCUIT.

WIRING FROM JUNCTION

BOX TO DISCONNECT

SWITCH AND FROM

DISCONNECT SWITCH

TO DAMPER ACTUATOR

BY EC.

WIRING FROM

ELECTRICAL

PANEL TO

JUNCTION BOX

PROVIDED BY EC.

FIRE, SMOKE, OR

FIRE/SMOKE DAMPER BY

MC.

FIRE ALARM SYSTEM

CONNECTION,

REQUIRED FOR

SMOKE AND

FIRE/SMOKE

DAMPERS. PROVIDED

BY FIRE ALARM

CONTRACTOR.

TO OTHER

DAMPERS

(SEE NOTE 2)

DISCONNECT SWITCH (LEVITON

#1221, OR APPROVED EQUAL)

WITH LOCKABLE COVER; AND

INDICATOR LIGHT (DAYTON/ZORO

RED, OR APPROVED EQUAL)

MOUNTED IN STAINLESS STEEL

PLATE ON UTILITY BOX THAT IS

MOUNTED WITHIN 18 INCHES OF

DAMPER ACCESS DOOR. PROVIDE

CIRCUIT LABEL ON PLATE.

ELECTRICAL PANEL LOCATED IN

ELECTRICAL ROOM, PROVIDED BY EC.

PILOT LIGHT BY EC.

ON WHEN SWITCH IS

ON. MOUNT NEXT TO

SWITCH.

DEVICE LABELING DETAIL

PROVIDE ALL WIRING DEVICES WITH A SELF-

ADHESIVE METALLIC LABEL WITH BLACK

LETTERING INDICATING PANEL AND CIRCUIT

NUMBER SERVING THE DEVICE. THE LABEL

SHALL MATCH THE CURRENT FACILITY'S

STANDARDS FOR NORMAL AND EMERGENCY

BRANCH CIRCUITS. 1

4 " MINIMUM LETTERING

HEIGHT.

GENERAL DETAIL NOTES:

A. COORDINATE LABELING WITH OWNER PRIOR TO INSTALLATION.

NTS

NTS

NTS

NTS

NTS

RECEPTACLE GROUNDING BOX DETAIL

METALLIC

BOXCONDUIT

CONDUIT

BUSHING

GROUNDING

SCREW

"GREEN"

GROUND

WIRE

NTS

PLASTIC

THROAT

BUSHING

GROUND WIRE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT STAMPPROGRAM MANAGER

321 4 5 6 7 8 9 10

ENGINEER OF RECORD

Charlotte Engineers, LLP 5838 Monroe Road Charlotte, NC 28212 704-531-3000 Michael Eaves

M L o c a l R e v it F ile s \R e v it

\4

C

E C e n tr a l M o d e l.

rv t

/1

/2

:1

:3

P

M

ES-002

ELECTRICAL - DETAILS VAMC EAST ORANGE AHU &

WATER-COOLED EQUIPMENT

UPGRADES

EAST ORANGE, NEW JERSEY

561-19-130

3/11/2021 CLH JMM

FULLY SPRINKLERED

EQP1

LDA PP-1A

NL1B

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT STAMPPROGRAM MANAGER

321 4 5 6 7 8 9 10

ENGINEER OF RECORD

Charlotte Engineers, LLP 5838 Monroe Road Charlotte, NC 28212 704-531-3000 Michael Eaves

M L o c a l R e v it F il e s \R e v it

\4

C

E C e n tr a l M o d e l.

rv t

/1

/2

:1

:3

P

M

ES-003

ELECTRICAL - PANEL SCHEDULES VAMC EAST ORANGE AHU &

WATER-COOLED EQUIPMENT

UPGRADES

EAST ORANGE, NEW JERSEY

561-19-130

3/11/2021 CLH JMM

BN-2

LPB-5A PP5-2

PB-176A

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT STAMPPROGRAM MANAGER

321 4 5 6 7 8 9 10

ENGINEER OF RECORD

Charlotte Engineers, LLP 5838 Monroe Road Charlotte, NC 28212 704-531-3000 Michael Eaves

M L o c a l R e v it F il e s \R e v it

\4

C

E C e n tr a l M o d e l.

rv t

/1

/2

:1

:3

P

M

ES-004

ELECTRICAL - PANEL SCHEDULES VAMC EAST ORANGE AHU &

WATER-COOLED EQUIPMENT

UPGRADES

EAST ORANGE, NEW JERSEY

561-19-130

3/11/2021 CLH JMM

PB-8

SWB B SWB C

PP-8

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT STAMPPROGRAM MANAGER

321 4 5 6 7 8 9 10

ENGINEER OF RECORD

Charlotte Engineers, LLP 5838 Monroe Road Charlotte, NC 28212 704-531-3000 Michael Eaves

M L o c a l R e v it F il e s \R e v it

\4

C

E C e n tr a l M o d e l.

rv t

/1

/2

:1

:3

P

M

ES-005

ELECTRICAL - PANEL SCHEDULES VAMC EAST ORANGE AHU &

WATER-COOLED EQUIPMENT

UPGRADES

EAST ORANGE, NEW JERSEY

561-19-130

3/11/2021 CLH JMM

#3CB-SWB

LP3-7B

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT STAMPPROGRAM MANAGER

321 4 5 6 7 8 9 10

ENGINEER OF RECORD

Charlotte Engineers, LLP 5838 Monroe Road Charlotte, NC 28212 704-531-3000 Michael Eaves

M L o c a l R e v it F il e s \R e v it

\4

C

E C e n tr a l M o d e l.

rv t

/1

/2

:1

:3

P

M

ES-006

ELECTRICAL - PANEL SCHEDULES VAMC EAST ORANGE AHU &

WATER-COOLED EQUIPMENT

UPGRADES

EAST ORANGE, NEW JERSEY

561-19-130

3/11/2021 CLH JMM

J

C-124

MECHANICAL

ROOM

C-135A

ENGINEERING

C-135

ENGINEERING

C-ELEV3

ELEVATOR

C-ELEV4

ELEVATOR

C-142

ELEVATOR

LOBBY

C-141

ELEVATOR

LOBBY

C-ELEV1

ELEVATOR

C-ELEV2

ELEVATOR

C-ELEV5

ELEVATOR

C-ELEV6

ELEVATOR

C--E-105

ELECTRIC

C-132

UTILITY

SHOPE

C-137

CONTROL

ROOM

C-126

MECHANICAL

ROOM

C-SHAFT3

SHAFTWAY

C-136

STORAGE

C -1

F

C O

R R

ID

O

R

C-132

UTILITY

SHOPE

EXISTING

MORGUE

AHU-10A

EXISTING

AHU-12

4 4

4 4

EXISTING SWBD-C

EXISTING

AHU-11

RV

EXISTING PANEL BE

EXISTING PANEL PP-7

EXISTING PANEL PP-8

C-132

UTILITY

SHOPE

C-132

UTILITY

SHOPE

C-132

UTILITY

SHOPE

REMOVE EXISTING SINGLE POINT CONNECTION TO VFD. DEMOLISH

JUNCTION BOX, WIRE, AND CONDUIT BACK TO SWB-C IN C-132. LABEL

BREAKERS AS SPARE.

REMOVE EXISTING ELECTRICAL CONNECTION BETWEEN AHU AND

DISCONNECT. DEMOLISH JUNCTION BOX, WIRE, DISCONNECT AND

CONDUIT BACK TO SWB-C IN C-132. LABEL BREAKER AS SPARE.

EXISTING AHU TO BE REMOVED BY MECHANICAL CONTRACTOR.

REMOVE ELECTRICAL CONNECTIONS FOR EXISTING MEDICAL VACUUM

PUMPS. REMOVE WIRING, DISCONNECTS AND CONDUIT BACK TO MAIN

BREAKER IN PANEL PP-8. LABEL BREAKER AS SPARE.

REMOVE EXISTING ELECTRICAL CONNECTION BETWEEN AHU AND

DISCONNECT. DEMOLISH JUNCTION BOX, WIRE, DISCONNECT AND

CONDUIT BACK TO SWB-C. LABEL BREAKER AS SPARE.

DEMOLITION KEYED NOTES

GENERAL NOTES

A. ALL EQUIPMENT BE U.L. LISTED.

B. THE ELECTRICAL CONTRACTOR SHALL CONNECT ALL MECHANICAL EQUIPMENT;

PROVIDE DISCONNECTS, WIRING AND CONDUIT, INSTALL STARTERS, AND MOUNT

AND WIRE VARIABLE SPEED DRIVES, UNLESS OTHERWISE NOTED.

C. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION WITH

OTHER TRADES TO ELIMINATE CONFLICT WITH OTHER TRADES. ANY WORK

INSTALLED BY THIS CONTRACTOR THAT RESULTS IN CONFLICT, DUE TO LACK OF

COORDINATION BETWEEN TRADES, SHALL BE CHANGED AS DIRECTED BY THE

ARCHITECT/ENGINEER WITHOUT ADDITIONAL COMPENSATION TO THE

CONTRACTOR.

D. THE DRAWINGS SHALL NOT BE SCALED FOR CONSTRUCTION PURPOSES. THE

SCALE, WHEN INDICATED IS INTENDED FOR GENERAL REFERENCE ONLY.

E. ALL SHUTDOWNS SHALL BE COORDINATED AND APPROVED THROUGH THE

OWNERS REPRESENTATIVE AND WILL REQUIRE ADVANCE NOTICE OF ONE WEEK.

THIS LENGTH MAY BE LONGER OR SHORTER FOR SOME SHUTDOWNS AND SHALL

BE AT THE OWNERS DISCRETION.

F. ALL EXISTING FIRE, FIRE/SMOKE, AND SMOKE DAMPERS WITHIN THE LIMITS OF

CONSTRUCTION AND BORDERING THE LIMITS OF CONSTRUCTION FOR THIS

PROJECT, SHALL BE REPLACED WITH NEW.

G. ALL EXISTING POWERED FIRE, FIRE/SMOKE, AND SMOKE DAMPERS WITHIN THE

LIMITS OF CONSTRUCTION AND BORDERING THE LIMITS OF CONSTRUCTION FOR

THIS PROJECT, SHALL BE BE CHECKED TO ENSURE THAT A LOCAL DISCONNECT IS

PROVIDED FOR EACH. IF A LOCAL DISCONNECT IS NOT CURRENTLY PROVIDED

THEN NEW SHALL BE INSTALLED.

H. CONSTRUCTION DEBRIS SHALL BE REMOVED DAILY.

I. CONTRACTOR TO TRACE ALL EXISTING CIRCUITS TO CONFIRM SOURCES IN FIELD

PRIOR TO BEGINNING DEMOLITION.

J. ALL LIGHTING FIXTURES LOCATED WITHIN THE AREA OF DEMOLITION TO BE

REMOVED/RELOCATED AS REQUIRED TO ACCOMMODATE THE REMOVAL OF

EXISTING EQUIPMENT.

K. ALL PANELS SHOWN ARE EXISTING TO REMAIN UNLESS OTHERWISE NOTED.

AHU-11

AHU-13

MORGUE AHU

AHU-12

ELECTRICAL

ROOM

SWB-C

AHU-12-S

VFD

AHU-12-R

VFD

KEY PLAN

GRAPHIC SCALE

( in Feet )

1 inch = 4 ft.

4 42 8 16

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT STAMPPROGRAM MANAGER

321 4 5 6 7 8 9 10

ENGINEER OF RECORD

Charlotte Engineers, LLP 5838 Monroe Road Charlotte, NC 28212 704-531-3000 Michael Eaves

M L o c a l R e v it F ile s \R e v it

\4

C

E C e n tr a l M o d e l.

rv t

/1

/2

:1

:5

P

M

ED-1-C-01

ELECTRICAL - DEMOLITION -

BUILDING 1 - C LEVEL

VAMC EAST ORANGE AHU &

WATER-COOLED EQUIPMENT

UPGRADES

EAST ORANGE, NEW JERSEY

561-19-130

3/11/2021 CLH JMM

FULLY SPRINKLERED

1/4" = 1'-0"

ELECTRICAL - DEMOLITION - AHU 12 & MORGUE AHU

C LEVEL

RV

C-133

OTHER

SPACE

EXISTING

AHU-13

VFD-SF-13 VFD-RF-6

1 1

Generic - 12"

C-132

UTILITY SHOPPE

REMOVE EXISTING SINGLE POINT CONNECTION TO VFD. DEMOLISH

JUNCTION BOX, WIRE, AND CONDUIT BACK TO SWB-C IN C-132. LABEL

BREAKERS AS SPARE.

REMOVE EXISTING ELECTRICAL CONNECTION BETWEEN AHU AND

DISCONNECT. DEMOLISH JUNCTION BOX, WIRE, DISCONNECT AND

CONDUIT BACK TO SWB-C IN C-132. LABEL BREAKER AS SPARE.

EXISTING AHU TO BE REMOVED BY MECHANICAL CONTRACTOR

DEMOLITION KEYED NOTES

GENERAL NOTES

A. ALL EQUIPMENT BE U.L. LISTED.

B. THE ELECTRICAL CONTRACTOR SHALL CONNECT ALL MECHANICAL EQUIPMENT;

PROVIDE DISCONNECTS, WIRING AND CONDUIT, INSTALL STARTERS, AND MOUNT

AND WIRE VARIABLE SPEED DRIVES, UNLESS OTHERWISE NOTED.

C. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION WITH

OTHER TRADES TO ELIMINATE CONFLICT WITH OTHER TRADES. ANY WORK

INSTALLED BY THIS CONTRACTOR THAT RESULTS IN CONFLICT, DUE TO LACK OF

COORDINATION BETWEEN TRADES, SHALL BE CHANGED AS DIRECTED BY THE

ARCHITECT/ENGINEER WITHOUT ADDITIONAL COMPENSATION TO THE

CONTRACTOR.

D. THE DRAWINGS SHALL NOT BE SCALED FOR CONSTRUCTION PURPOSES. THE

SCALE, WHEN INDICATED IS INTENDED FOR GENERAL REFERENCE ONLY.

E. ALL SHUTDOWNS SHALL BE COORDINATED AND APPROVED THROUGH THE

OWNERS REPRESENTATIVE AND WILL REQUIRE ADVANCE NOTICE OF ONE WEEK.

THIS LENGTH MAY BE LONGER OR SHORTER FOR SOME SHUTDOWNS AND SHALL

BE AT THE OWNERS DISCRETION.

F. ALL EXISTING FIRE, FIRE/SMOKE, AND SMOKE DAMPERS WITHIN THE LIMITS OF

CONSTRUCTION AND BORDERING THE LIMITS OF CONSTRUCTION FOR THIS

PROJECT, SHALL BE REPLACED WITH NEW.

G. ALL EXISTING POWERED FIRE, FIRE/SMOKE, AND SMOKE DAMPERS WITHIN THE

LIMITS OF CONSTRUCTION AND BORDERING THE LIMITS OF CONSTRUCTION FOR

THIS PROJECT, SHALL BE BE CHECKED TO ENSURE THAT A LOCAL DISCONNECT IS

PROVIDED FOR EACH. IF A LOCAL DISCONNECT IS NOT CURRENTLY PROVIDED

THEN NEW SHALL BE INSTALLED.

H. CONSTRUCTION DEBRIS SHALL BE REMOVED DAILY.

I. CONTRACTOR TO TRACE ALL EXISTING CIRCUITS TO CONFIRM SOURCES IN FIELD

PRIOR TO BEGINNING DEMOLITION.

J. ALL LIGHTING FIXTURES LOCATED WITHIN THE AREA OF DEMOLITION TO BE

REMOVED/RELOCATED AS REQUIRED TO ACCOMMODATE THE REMOVAL OF

EXISTING EQUIPMENT.

K. ALL PANELS SHOWN ARE EXISTING TO REMAIN UNLESS OTHERWISE NOTED.

AHU-11

AHU-13

MORGUE AHU

AHU-12

ELECTRICAL

ROOM

SWB-C

AHU-12-S

VFD

AHU-12-R

VFD

KEY PLAN

GRAPHIC SCALE

( in Feet )

1 inch = 4 ft.

4 42 8 16

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT STAMPPROGRAM MANAGER

321 4 5 6 7 8 9 10

ENGINEER OF RECORD

Charlotte Engineers, LLP 5838 Monroe Road Charlotte, NC 28212 704-531-3000 Michael Eaves

M L o c a l R e v it F ile s \R e v it

\4

C

E C e n tr a l M o d e l.

rv t

/1

/2

:1

:5

P

M

ED-1-C-02

ELECTRICAL - DEMOLITION -

BUILDING 1 - C LEVEL

VAMC EAST ORANGE AHU &

WATER-COOLED EQUIPMENT

UPGRADES

EAST ORANGE, NEW JERSEY

561-19-130

3/11/2021 CLH JMM

FULLY SPRINKLERED

1/4" = 1'-0"

ELECTRICAL - DEMOLITION - AHU 13

C LEVEL

B-158C

MSDS-SPD

B-177A

SUPERVISOR

OFFICE

B-177B

NEEDLE

ROOM

B-165

MECHANICAL

ROOM

B-165A

IRM

CLOSET

B-177

GENERAL

STORAGE

B-175A

DUMB/

WAITER

B-175B

DUMB/

WAITER

B-SHAFT1

SHAFTWAY

B-SHAFT2

SHAFTWAY

B-ELEV5

ELEVATOR

B-176D

ELEVATOR

LOBBY

B-ELEV6

ELEVATOR

B-ELEV1

ELEVATOR

B-ELEV2

ELEVATOR

B-E-105

ELECTRIC

B-176C

ELEVATOR

LOBBY

B-ELEV4

ELEVATOR

B-ELEV3

ELEVATOR

B -1

B

S T

O R

A G

E

B-176B

CORRIDOR

EXISTING

MAILROOM

AHU

EXISTING

MSDS

AHU

EX

DISCONNECT

40A/3/1P

EX DISCONNECT

208/3P

RV

REMOVE EXISTING ELECTRICAL CONNECTIONS BETWEEN AHU AND

DISCONNECT. DEMOLISH JUNCTION BOX, WIRE DISCONNECT, AND

CONDUIT BACK TO PANEL PB176 IN ROOM B-176. LABEL BREAKERS AS

SPARE.

REMOVE EXISTING ELECTRICAL CONNECTION BETWEEN AHU AND

DISCONNECT. DEMOLISH JUNCTION BOX, WIRE DISCONNECT AND CONDUIT

BACK TO SOURCE. LABEL BREAKER AS SPARE.

EXISTING AHU TO BE REMOVED BY MECHANICAL CONTRACTOR.

DEMOLITION KEYED NOTES

GENERAL NOTES

A. ALL EQUIPMENT BE U.L. LISTED.

B. THE ELECTRICAL CONTRACTOR SHALL CONNECT ALL MECHANICAL EQUIPMENT;

PROVIDE DISCONNECTS, WIRING AND CONDUIT, INSTALL STARTERS, AND MOUNT

AND WIRE VARIABLE SPEED DRIVES, UNLESS OTHERWISE NOTED.

C. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION WITH

OTHER TRADES TO ELIMINATE CONFLICT WITH OTHER TRADES. ANY WORK

INSTALLED BY THIS CONTRACTOR THAT RESULTS IN CONFLICT, DUE TO LACK OF

COORDINATION BETWEEN TRADES, SHALL BE CHANGED AS DIRECTED BY THE

ARCHITECT/ENGINEER WITHOUT ADDITIONAL COMPENSATION TO THE

CONTRACTOR.

D. THE DRAWINGS SHALL NOT BE SCALED FOR CONSTRUCTION PURPOSES. THE

SCALE, WHEN INDICATED IS INTENDED FOR GENERAL REFERENCE ONLY.

E. ALL SHUTDOWNS SHALL BE COORDINATED AND APPROVED THROUGH THE

OWNERS REPRESENTATIVE AND WILL REQUIRE ADVANCE NOTICE OF ONE WEEK.

THIS LENGTH MAY BE LONGER OR SHORTER FOR SOME SHUTDOWNS AND SHALL

BE AT THE OWNERS DISCRETION.

F. ALL EXISTING FIRE, FIRE/SMOKE, AND SMOKE DAMPERS WITHIN THE LIMITS OF

CONSTRUCTION AND BORDERING THE LIMITS OF CONSTRUCTION FOR THIS

PROJECT, SHALL BE REPLACED WITH NEW.

G. ALL EXISTING POWERED FIRE, FIRE/SMOKE, AND SMOKE DAMPERS WITHIN THE

LIMITS OF CONSTRUCTION AND BORDERING THE LIMITS OF CONSTRUCTION FOR

THIS PROJECT, SHALL BE BE CHECKED TO ENSURE THAT A LOCAL DISCONNECT IS

PROVIDED FOR EACH. IF A LOCAL DISCONNECT IS NOT CURRENTLY PROVIDED

THEN NEW SHALL BE INSTALLED.

H. CONSTRUCTION DEBRIS SHALL BE REMOVED DAILY.

I. CONTRACTOR TO TRACE ALL EXISTING CIRCUITS TO CONFIRM SOURCES IN FIELD

PRIOR TO BEGINNING DEMOLITION.

J. ALL LIGHTING FIXTURES LOCATED WITHIN THE AREA OF DEMOLITION TO BE

REMOVED/RELOCATED AS REQUIRED TO ACCOMMODATE THE REMOVAL OF

EXISTING EQUIPMENT.

K. ALL PANELS SHOWN ARE EXISTING TO REMAIN UNLESS OTHERWISE NOTED.

MAIL ROOM AHU

MSDS AHU

KEY PLAN

GRAPHIC SCALE

( in Feet )

1 inch = 4 ft.

4 42 8 16

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT STAMPPROGRAM MANAGER

321 4 5 6 7 8 9 10

ENGINEER OF RECORD

Charlotte Engineers, LLP 5838 Monroe Road Charlotte, NC 28212 704-531-3000 Michael Eaves

M L o c a l R e v it F ile s \R e v it

\4

C

E C e n tr a l M o d e l.

rv t

/1

/2

:1

:5

P

M

ED-1-B-01

ELECTRICAL - DEMOLITION -

BUILDING 1 - B LEVEL

VAMC EAST ORANGE AHU &

WATER-COOLED EQUIPMENT

UPGRADES

EAST ORANGE, NEW JERSEY

561-19-130

3/11/2021 CLH JMM

FULLY SPRINKLERED

1/4" = 1'-0"

ELECTRICAL - DEMOLITION - MSDS AHU

B LEVEL

S M

J

B-148

MORGE,

AUTOPSY

SUITE

B-150B

NEW

BODY BOX

B-150

STAGING

ROOM

B-150A

VIEWING

ROOM

B-152

VESTIBULE

B-SHAFT 7

SHAFTWAY

B-154

BIO-MED

OFFICE

B-ELEV 11

ELEVATOR

B-151A

ELEVATOR

LOBBY

B-151

CORRIDOR

B-148A

B -1

C L O

S E

T

B-144

UNIFORM ROOM

EXISTING

EVAPORATOR

UNIT

RV

1B-S6

STAIR 6

B-120

REFRIG

B-119

REFRIG

B-118

REFRIG

B -1

C O

R R

ID

O

R

EX EVAPORATING UNIT

EX. EVAPORATING UNIT

EX. EVAPORATING UNIT

RV

RV

RV

B-173A

CORRIDOR

B-173

WALKIN

REFRIG

B-SHAFT3

SHAFTWAY

B-174B

MAIL

ROOM

B -1

A

C O

R R

ID

O

R

EX. EVAPORATING UNIT

RV

B-128C

WALKIN

REFRIG

B -1

C

C O

R R

ID

O

R

B-128B

FREEZER

EX. EVAPORATING UNIT

EX. EVAPORATING UNIT

RV

RV

RV

RV

RV

RV

REMOVE EXISTING SINGLE POINT CONNECTION TO EVAPORATOR UNIT.

DEMOLISH JUNCTION BOX, WIRE, CONDUIT AND DISCONNECT BACK TO

SOURCE IN PANEL PP-5-1, PP-5-2, PP-5-3 IN KITCHEN AREA. LABEL

BREAKERS AS SPARE.

ENTIRE COOLER TO BE REMOVED BY MECHANICAL CONTRACTOR.

DISCONNECT ELECTRICAL CONNECTION FOR AUTOMATIC DOOR. PROTECT

FOR RE-USE.

REMOVE ELECTRICAL CONNECTION BACK TO PANEL PP-5 IN KITCHEN.

LABEL BREAKER AS SPARE.

REMOVE EXISTING LIGHT. MAINTAIN LIGHTING CIRCUIT FOR RE-USE WITH

NEW LIGHT FIXTURES.

EXISTING LIGHT FIXTURES IN THIS AREA TO REMAIN.

DEMOLITION KEYED NOTES

B-S6

STAIR 6

B-119C

UTILITY

SHOP

B-128D O.R. A/C

EX ELECTRICAL

GEAR

REMOVE ELECTRICAL CONNECTION,

WIRING, DISCONNECT AND CONDUIT FOR

EXISTING CONDENSING UNIT SERVING

PRODUCE COOLER.

REMOVE ELECTRICAL CONNECTION,

WIRING, DISCONNECT AND CONDUIT FOR

EXISTING CONDENSING UNIT SERVING

PRODUCE COOLER.

EXISTING PANEL EQP1

EXISTING PANEL PM1

GENERAL NOTES

A. ALL EQUIPMENT BE U.L. LISTED.

B. THE ELECTRICAL CONTRACTOR SHALL CONNECT ALL MECHANICAL EQUIPMENT;

PROVIDE DISCONNECTS, WIRING AND CONDUIT, INSTALL STARTERS, AND MOUNT

AND WIRE VARIABLE SPEED DRIVES, UNLESS OTHERWISE NOTED.

C. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION WITH

OTHER TRADES TO ELIMINATE CONFLICT WITH OTHER TRADES. ANY WORK

INSTALLED BY THIS CONTRACTOR THAT RESULTS IN CONFLICT, DUE TO LACK OF

COORDINATION BETWEEN TRADES, SHALL BE CHANGED AS DIRECTED BY THE

ARCHITECT/ENGINEER WITHOUT ADDITIONAL COMPENSATION TO THE

CONTRACTOR.

D. THE DRAWINGS SHALL NOT BE SCALED FOR CONSTRUCTION PURPOSES. THE

SCALE, WHEN INDICATED IS INTENDED FOR GENERAL REFERENCE ONLY.

E. ALL SHUTDOWNS SHALL BE COORDINATED AND APPROVED THROUGH THE

OWNERS REPRESENTATIVE AND WILL REQUIRE ADVANCE NOTICE OF ONE WEEK.

THIS LENGTH MAY BE LONGER OR SHORTER FOR SOME SHUTDOWNS AND SHALL

BE AT THE OWNERS DISCRETION.

F. ALL EXISTING FIRE, FIRE/SMOKE, AND SMOKE DAMPERS WITHIN THE LIMITS OF

CONSTRUCTION AND BORDERING THE LIMITS OF CONSTRUCTION FOR THIS

PROJECT, SHALL BE REPLACED WITH NEW.

G. ALL EXISTING POWERED FIRE, FIRE/SMOKE, AND SMOKE DAMPERS WITHIN THE

LIMITS OF CONSTRUCTION AND BORDERING THE LIMITS OF CONSTRUCTION FOR

THIS PROJECT, SHALL BE BE CHECKED TO ENSURE THAT A LOCAL DISCONNECT IS

PROVIDED FOR EACH. IF A LOCAL DISCONNECT IS NOT CURRENTLY PROVIDED

THEN NEW SHALL BE INSTALLED.

H. CONSTRUCTION DEBRIS SHALL BE REMOVED DAILY.

I. CONTRACTOR TO TRACE ALL EXISTING CIRCUITS TO CONFIRM SOURCES IN FIELD

PRIOR TO BEGINNING DEMOLITION.

J. ALL LIGHTING FIXTURES LOCATED WITHIN THE AREA OF DEMOLITION TO BE

REMOVED/RELOCATED AS REQUIRED TO ACCOMMODATE THE REMOVAL OF

EXISTING EQUIPMENT.

K. ALL PANELS SHOWN ARE EXISTING TO REMAIN UNLESS OTHERWISE NOTED.

PRODUCE

COOLER

WALK-IN

REFRIGERATOR

MILKBOX

WALK-IN

KEY PLAN

GRAPHIC SCALE

( in Feet )

1 inch = 4 ft.

4 42 8 16

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT STAMPPROGRAM MANAGER

321 4 5 6 7 8 9 10

ENGINEER OF RECORD

Charlotte Engineers, LLP 5838 Monroe Road Charlotte, NC 28212 704-531-3000 Michael Eaves

M L o c a l R e v it F ile s \R e v it

\4

C

E C e n tr a l M o d e l.

rv t

/1

/2

:1

:5

P

M

ED-1-B-02

ELECTRICAL - DEMOLITION -

BUILDING 1 - B LEVEL

VAMC EAST ORANGE AHU &

WATER-COOLED EQUIPMENT

UPGRADES

EAST ORANGE, NEW JERSEY

561-19-130

3/11/2021 CLH JMM

FULLY SPRINKLERED

1/4" = 1'-0"

ELECTRICAL - DEMOLITION - MORGUE WALK-IN

1/4" = 1'-0"

ELECTRICAL - DEMOLITION - PRODUCE COOLER

1/4" = 1'-0"

ELECTRICAL - DEMOLITION - MILKBOX WALK-IN

1/4" = 1'-0"

ELECTRICAL - DEMOLITION - WALK-IN REFRIGERATOR

B LEVEL

1/4" = 1'-0"

ELECTRICAL - DEMOLITION - MECHANICAL ROOM

A-146

ZZ CORRIDOR

EXISTING

A LEVEL-LAB

AHU

EXISTING

A LEVEL-LAB

ERU

EL1B

EL1A

NL1A NL1B NL1J

LDA

RM

RM

RM RM RM

RM

RM

RV

REMOVE EXISTING ELECTRICAL CONNECTIONS TO EXISTING AHUS.

DEMOLISH JUNCTION BOX, WIRE DISCONNECT, AND CONDUIT BACK TO

MCC-1.

EXISTING AHU AND ERU TO BE REMOVED BY MECHANICAL CONTRACTOR.

DEMOLISH EXISTING MCC AND REMOVE WIRE AND CONDUIT BACK TO

SOURCE IN PANEL LDA.

DEMOLITION KEYED NOTES

GENERAL NOTES

A. ALL EQUIPMENT BE U.L. LISTED.

B. THE ELECTRICAL CONTRACTOR SHALL CONNECT ALL MECHANICAL EQUIPMENT;

PROVIDE DISCONNECTS, WIRING AND CONDUIT, INSTALL STARTERS, AND MOUNT

AND WIRE VARIABLE SPEED DRIVES, UNLESS OTHERWISE NOTED.

C. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION WITH

OTHER TRADES TO ELIMINATE CONFLICT WITH OTHER TRADES. ANY WORK

INSTALLED BY THIS CONTRACTOR THAT RESULTS IN CONFLICT, DUE TO LACK OF

COORDINATION BETWEEN TRADES, SHALL BE CHANGED AS DIRECTED BY THE

ARCHITECT/ENGINEER WITHOUT ADDITIONAL COMPENSATION TO THE

CONTRACTOR.

D. THE DRAWINGS SHALL NOT BE SCALED FOR CONSTRUCTION PURPOSES. THE

SCALE, WHEN INDICATED IS INTENDED FOR GENERAL REFERENCE ONLY.

E. ALL SHUTDOWNS SHALL BE COORDINATED AND APPROVED THROUGH THE

OWNERS REPRESENTATIVE AND WILL REQUIRE ADVANCE NOTICE OF ONE WEEK.

THIS LENGTH MAY BE LONGER OR SHORTER FOR SOME SHUTDOWNS AND SHALL

BE AT THE OWNERS DISCRETION.

F. ALL EXISTING FIRE, FIRE/SMOKE, AND SMOKE DAMPERS WITHIN THE LIMITS OF

CONSTRUCTION AND BORDERING THE LIMITS OF CONSTRUCTION FOR THIS

PROJECT, SHALL BE REPLACED WITH NEW.

G. ALL EXISTING POWERED FIRE, FIRE/SMOKE, AND SMOKE DAMPERS WITHIN THE

LIMITS OF CONSTRUCTION AND BORDERING THE LIMITS OF CONSTRUCTION FOR

THIS PROJECT, SHALL BE BE CHECKED TO ENSURE THAT A LOCAL DISCONNECT IS

PROVIDED FOR EACH. IF A LOCAL DISCONNECT IS NOT CURRENTLY PROVIDED

THEN NEW SHALL BE INSTALLED.

H. CONSTRUCTION DEBRIS SHALL BE REMOVED DAILY.

I. CONTRACTOR TO TRACE ALL EXISTING CIRCUITS TO CONFIRM SOURCES IN FIELD

PRIOR TO BEGINNING DEMOLITION.

J. ALL LIGHTING FIXTURES LOCATED WITHIN THE AREA OF DEMOLITION TO BE

REMOVED/RELOCATED AS REQUIRED TO ACCOMMODATE THE REMOVAL OF

EXISTING EQUIPMENT.

K. ALL PANELS SHOWN ARE EXISTING TO REMAIN UNLESS OTHERWISE NOTED.

KEY PLAN

AREA OF

WORK

GRAPHIC SCALE

( in Feet )

1 inch = 4 ft.

4 42 8 16

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100%…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .