These are construction design drawings for the rehabilitation of three residential units (119, 120, and 124) at Pine Island Community in Everglades National Park, located in Miami-Dade County, Florida. The project, dated November 21, 2022, encompasses comprehensive architectural, structural, mechanical, plumbing, electrical, and fire protection work prepared by the National Park Service Denver Service Center.

The scope of work includes demolition of existing roofing, interior finishes, mechanical and electrical systems, and plumbing fixtures across all three units, followed by installation of new systems and finishes. Key construction elements include: new standing seam metal roofing with rafter overbuild, replacement of water-damaged wood roof decking, new terrazzo flooring with concrete slab infill, interior wall and ceiling finishes with drywall and paint, new kitchen and bathroom fixtures, new HVAC system (2-ton heat pump with air handling unit), new plumbing with domestic water service and vent systems, new electrical distribution with updated lighting and outlets, and fire sprinkler system installation. The project requires coordination among multiple trades including general, mechanical, plumbing, electrical, and fire protection contractors. Construction documents specify compliance with 2015 International Building Code, 2015 International Plumbing Code, 2018 International Energy Conservation Code, and applicable NFPA standards. The drawings indicate standard residential occupancy (R-3) with ADA accessibility requirements where applicable.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

COVER SHEET G001

NORTH

MONROE CO.

CARD SO

UND RO

ADENVIRONMENTAL

KEY WEST

TO 1

CENTER

FLORIDA

BAY

BAY

FLAMINGO

V.C.

SABLE

CAPE

WHITEWATER

OCEAN

V.C.

SOUND

BARNES

MCLAUGHLIN

KEY

MEXICO

GULF OF

OCHOPEE

NAPLES

TO

EVERGLADES

COAST

GULF

V.C.

CITY

FORT MYERS

BIG CYPRESS29

TO

RESERVATION

FL

O

R

ID

A' S

TU

R

N

PI

KE

MONROE COUNTY

HIDDEN LAKE

CENTER

BEARD

DANIEL

LOOP

D

AD

E C

O U

N

TY

M O

N R

O E

C O

U N

TY

ROAD

TAMIAMI

PALM

ROYAL

CENTER

HQ.

RESEARCH

CITY

MAIN

V.C.

FLORIDA

CITY

LEISURE

HOMESTEAD

CHEKIKA

VALLEY

SHARK

MUCCOSUKEE

PRESERVE

COLLIER COUNTY

TAMIAMI TRAIL

NATIONAL

INDIAN

ATLANTIC

LARGO

KEY

NATIONAL

DADE CO.

PARK

BISCAYNE

DRIVECANAL

FORT LAUDERDALE

MIAMI

TO

UNESCO

EVERGLADES NATIONAL PARK

WORLD HERITAGE SITE

PARK OFFICIAL FOR LIMITATIONS.

FEDERAL GOVERNMENT. CHECK WITH LOCAL

PARK HAVE BEEN ACQUIRED BY THE

BOUNDARY OF THE EVERGLADES NATIONAL

NOT ALL LANDS INSIDE THE AUTHORIZED

NOTE

SWAMP OR SLOUGH

PUBLIC AIRPORTS

OBSERVATION TOWER

INFORMATION CENTER

RANGER STATION

PARK HEADQUARTERS

VISITOR CENTER

HQ.

V.C.

CREEK

LEGEND

PARK BOUNDARY

COUNTY LINE

BASIC DATA: BOUNDARY MAPS 160/20,013B 9/89; 160/20,012 3/85; PARK MINI FOLDER 1992; REVISED & REDRAWN 5/93. UPDATED 11/98. SGS.

MEXICO

OF

GULF

LE

E

C O

ATLANTIC

FLORIDA BAY

EVERGLADES

PARK

NATIONAL

KEY LARGO

OCEAN

NORTH MIAMI BEACH

FORT LAUDERDALE

H

EN

D R

Y C

O

KENDALL

PALM BEACH CO.

DADE CO.

BROWARD CO.

FLORIDA CITY

HOMESTEAD

PRINSTON

C O

LL

IE

R C

O

MONROE CO.

PRESERVE

NATIONAL

BIG CYPRESS

MIAMI

NATIONAL

BISCAYNE

PARK

HOLLYWOOD

SCALE IN MILES

10 0 10 20SOUTHERN

FLORIDA

176672

SCALE IN MILES

SCALE IN KILOMETERS

5 0

15105

5 10 LOCATION WITHIN PARK

NAME OF PARK

TITLE OF SHEET

EVERGLADES NATIONAL PARK

PINE ISLAND COMMUNITY

STATEREGION COUNTY

SOUTHEAST FLORIDAMIAMI-DADE

PMIS / PKG. NO.

SHEET

DRAWING NO.

OF 34

DATE:

TECH. REVIEW:

DRAWN:

DESIGNED:REVISIONS SUB SHEET NO.

NATIONAL PARK SERVICE

DENVER SERVICE CENTER

DEPARTMENT OF THE INTERIOR

UNITED STATES

KS/EW

EW / CH

11/21/2022

KS / CH 305612

11/21/2022

5' -3

8'-1"

'-7

2'-6"

1' -1

33'-0"

1' -5

6'

-5

8' -7

AREA OF FINISH DEMOLITION

(CEILING AND/OR FLOORS)

EXISTING CONSTRUCTION

TO REMAIN

EXISTING CONSTRUCTION

TO BE DEMOLISHED

DOOR TO BE DEMOLISHED

FRAME TO REMAIN

DOOR AND FRAME TO

REMAIN

D101 SCALE 14" = 1'

D101 SCALE 14" = 1'

A INTERIOR DOORS: DEMOLISH INTERIOR DOORS AND HARDWARE. INTERIOR DOOR FRAMES SHALL REMAIN.

B EXTERIOR DOORS: DEMOLISH DOORS AND HARDWARE; GENERAL CONTRACTOR TO EVAULATE CONDITION OF

FRAME AND ADVISE OWNER

C INTERIOR FINISHES: PLASTER AND PLASTERBOARD WALL AND CEILING FINISHES SHALL BE CUT, TRENCHED, DEMOLISHED AS REQUIRED TO INSTALL NEW WORK. MINIMIZE INTERIOR FINISH DEMOLITION, UTILIZE DEMOLISHED CEILING AREA IN CORRIDOR FOR ACCESS TO ATTIC SPACE. FINISH DEMOLITION SHALL BE CARRIED OUT BY MAKING CLEAN STRAIGHT CUTS IN FINISHES AND DEMOLISHING FINISHES WITHIN CUT AREAS. WALL AND CEILING FRAMING SHALL BE PRESERVED UN-DAMAGED. ALL DAMAGE RESULTING FROM DEMO WORK SHALL BE PATCHED AND

REPAIRED TO MATCH ADJACENT WALL FINISH AND TEXTURE.

D FLOOR FINISHES: TERRAZZO FLOOR AND CONCRETE SLAB SUBSTRATE SHALL BE CUT, TRENCED, DEMOLISHED AS REQUIRED TO INSTALL NEW WORK. MINIMIZE FLOOR SLAB DEMOLITION. LOCATE UNDERSLAB PIPING AND OTHER UTILITIES BY NON-DESTRUCTIVE MEANS PRIOR TO BEGINNING DEMOLITION. SAWCUT TERRAZZO FINISH AND

CONCRETE SLAB IN CLEAN STRAIGHT AND ORTHOGONAL LINES.

E INTERIOR WOOD TRIM: BASE TRIM AND DOOR TRIM SHALL BE DEMOLISHED ONLY WHERE REQUIRED TO CARRY OUT NEW WORK. SALVAGE TRIM FOR REUSE. PROVIDE NEW TRIM WHERE REUSE OF SALVAGED TRIM IS NOT

POSSIBLE

F WINDOWS: EXTERIOR WINDOWS ARE NOT IN CONTRACT. PROTECT WINDOWS FROM DAMAGE DURING THE

COURSE OF THE NEW WORK

G ROOF: DEMOLISH ROOFING DOWN TO THE ROOF DECK. INSPECT ROOF DECK FOR WATER DAMAGE AND SUITABILITY FOR INSTALLATION OF NEW ROOF. SURVEY FLAT ROOF AREAS WITH TONGUE AND GROOVE WOOD PLANK DECK FOR WATER DAMAGE BEYOND THE KNOWN DAMAGED AREAS INDICATED ON DRAWINGS. ADVISE CONTRACT OFFICER OF FINDINGS PRIOR TO CARRYING OUT ADDITIONAL DEMOLITION OR INSTALLING NEW WORK.

ANY DETERIORATED SUBSTRATE (PLYWOOD SHEATHING, BUILDING WRAP, ECT) IS TO BE REMOVED.

H WINDOWS SHADES/BLINDS: DEMOLISH LOUVRE BLINDS, VALENCES, HANGERS AND ALL BRACKETS AND ANCHORS AT EACH WINDOW IN EACH UNIT. PATCH AND REPAIR ANY DAMAGE MADE BY REMOVAL OF BRACKETS, ANCHORS, OR OTHER.

D1 DEMOLISH ALUMINUM-FRAMED SCREENWALL SYSTEM

D2 DEMOLISH CONCRETE CONDENSING UNIT PAD

D3 DEMOLISH ROOF OVERHANG SOFFITS AND VENTS

D4 DEMOLISH CLOSET SLIDING DOORS AND TRACKS

D5 DEMOLISH KITCHEN CABINETS

D6 DEMOLISH KITCHEN APPLIANCES

D7 DEMOLISH FLOOR TILE (UNIT 119 ONLY)

D8 DEMOLISH SINK VANITIES, WALL CABINETS, MIRRORS, TOWEL AND TOILET PAPER HOLDERS, SOAP TRAYS, ETC AND

ALL FASTENERS OR ANCHORS

D9 DEMOLISH WALL TILE AND SUBSTRATE AND/OR BACKERBOARD.

D10 EXISTING LIGHT SHELF TO REMAIN - REFER TO ELECTRICAL

D11 DEMOLISH EXISTING WATER-DAMAGED WOOD PLANK ROOF DECK, HATCHED AREA INDICATES APPROXIMATE

EXTENTS OF KNOWN DAMAGE. ALL DETERIORATED OR WATER-DAMAGED DECK SHALL BE REMOVED, ADVISE

CONTRACT OFFICER IF DAMAGE AREA IS FOUND TO EXTEND BEYOND THE INDICATED EXTENTS.

D12 DEMOLISH WOOD SHELVING, BRACKETS, SUPPORTS, HOOKS, HANGERS, ANCHORS, ETC. INSIDE OF CLOSET. PATCH

HOLES.

D13 SAWCUT AND DEMOLISH CONCRETE FLOOR SLAB FOR EXTENTS REQUIRED TO DEMOLISH EXISTING UNDERSLAB PIPING AND INSTALL NEW WORK. HATCHED AREA INDICATES APPROXIMATE EXTENTS. REFER TO NEW WORK

DRAWINGS FOR PATCH AND REPAIR SCOPE.

D14 DEMOLISH PLASTER AND/OR GYPSUM BOARD WALL FINISHES BOTH SIDES OF WALL AND AS REQUIRED TO

DEMOLISH EXISTING ELECTRICAL AND PLUMBING, AND INSTALL NEW WORK.

D15 DEMOLISH EXISTING WALL FROM 42" AFF TO SLOPED CEILING

D16 DEMOLISH WALLCOVERING FROM FULL EXTENTS OF WALL

D17 DEMOLISH CLOSET IN CORRIDOR AND BEDROOM A INCLUDING WOOD SHELVING, DOORS, AND OTHER

COMPONENTS.

D18 DEMOLISH SURFACE-MOUNTED HOUSE NUMBERS. EXACT LOCATION MAY VARY AT EACH UNIT.

D19 DEMOLISH HOSE BRACKET

D20 DEMOLISH ANTENNA AND ASSOCIATED BRACKETS AND WIRING. PATCH AND REPAIR EXISTING FINISHES AS

REQUIRED. REFER TO ELECTRICAL FOR SCOPE OF SATELLITE DISH

D21 DEMOLISH CORRUGATED METAL PANEL HURRICANE SHUTTERS AND SUPPORTS AT TOP AND BOTTOM OF WALL.

PATCH AND REPAIR SUBSTRATES.

D22 DEMOLISH PLASTER AND/OR DRYWALL CEILING FINISH FOR EXTENTS INDICATED.

D23 REMOVE WALL MOUNTED FIRE EXTINGUISHER

349*��)*241.8-�1&:3)7>�)4478 &3)�<&11�&9�:3.9� 11��431>

1/4" = 1' - 0" SCALE OF FEET

0'4' 4' 8'

1*G*3)

SCREENED

PORCH

D

D104 D104

D

4 G*3*7&1�349*8

0*>�349*8

24'-2"

2' -9

'-6

54'-0"

4' -6

16'-10"

2' -9

5'

-4

2'-10"

'-4

3'-0"

11'-8"

'-3

AREA OF FINISH DEMOLITION

(CEILING AND/OR FLOORS)

EXISTING CONSTRUCTION

TO REMAIN

EXISTING CONSTRUCTION

TO BE DEMOLISHED

DOOR TO BE DEMOLISHED

FRAME TO REMAIN

DOOR AND FRAME TO

REMAIN

D102 SCALE 14" = 1'

A INTERIOR DOORS: DEMO INTERIOR DOORS AND HARDWARE. INTERIOR DOOR FRAMES SHALL REMAIN.

B EXTERIOR DOORS: DEMOLISH EXTERIOR DOOR AND HARDWARE. GENERAL CONTRACTOR TO EVALUATE CONDITION

OF FRAME AND ADVISE CONTRACT OFFICER. REFER TO KEYNOTES FOR SCOPE OF SCREEN DOORS.

C INTERIOR FINISHES SHALL BE CUT, TRENCHED, DEMOLISHED AS REQUIRED TO INSTALL NEW WORK. MINIMIZE

INTERIOR FINISH DEMO, UTILIZE DEMOLISHED CEILING AREA IN CORRIDOR FOR ACCESS TO ATTIC SPACE. FINISH DEMO SHALL BE CARRIED OUT BY MAKING CLEAN STRAIGHT CUTS IN FINISHES AND DEMOLISHING FINISHES WITHIN CUT AREAS. WALL AND CEILING FRAMING SHALL BE PRESERVED UN-DAMAGED. ALL DAMAGE RESULTING FROM DEMO WORK SHALL BE PATCHED AND REPAIRED TO MATCH ADJACENT WALL FINISH AND TEXTURE.

D FLOOR FINISHES: TERRAZZO FLOOR AND CONCRETE SLAB SUBSTRATE SHALL BE CUT, TRENCED, DEMOLISHED AS REQUIRED TO INSTALL NEW WORK. MINIMIZE FLOOR SLAB DEMO. LOCATE UNDERSLAB PIPING AND OTHER UTILITIES BY NON-DESTRUCTIVE MEANS PRIOR TO BEGINNING DEMO. SAWCUT TERRAZZO FINISH AND CONCRETE

SLAB IN CLEAN STRAIGHT AND ORTHOGONAL LINES.

E INTERIOR WOOD TRIM: BASE TRIM AND DOOR TRIM SHALL BE DEMOLISHED ONLY WHERE REQUIRED TO CARRY OUT NEW WORK. SALVAGE TRIM FOR REUSE. PROVIDE NEW TRIM WHERE REUSE OF SALVAGED TRIM IS NOT

POSSIBLE (PROFILE TO MATCH EXISTING TRIM)

F WINDOWS: EXTERIOR WINDOWS NIC. PROTECT WINDOWS AND HURRICANE SHUTTERS FROM DAMAGE DURING

THE COURSE OF CONSTRUCTION.

G EXTERIOR WOOD SIDING: DEMO EXISTING WOOD SIDING AND FASTENERS IN ENTIRETY. REMOVE BUILDING PAPER OR BUILDING WRAP IF PRESENT. ADVISE CONTRACT OFFICER OF DETERIORATED SUBSTRATE AND AWAIT DIRECTION

ON REPLACEMENT MATERIALS AND METHODS.

H WINDOWS SHADES/BLINDS: DEMO LOUVRE BLINDS, VALENCES, HANGERS AND ALL BRACKETS AND ANCHORS AT EACH WINDOW AND SLIDING DOOR IN EACH UNIT. PATCH AND REPAIR ANY DAMAGE MADE BY REMOVAL OF

BRACKETS, ANCHORS, OR OTHER COMPONENTS TO MATCH ADJACENT EXISTING SURFACES.

D1 DEMOLISH ALUMINUM-FRAMED SCREENWALL SYSTEM

D2 DEMOLISH CONCRETE CONDENSING UNIT PAD

D3 DEMOLISH ROOF OVERHANG SOFFITS AND VENTS

D4 DEMOLISH CLOSET SLIDING DOORS AND TRACKS

D5 DEMOLISH KITCHEN CABINETS

D6 DEMOLISH KITCHEN APPLIANCES

D7 DEMOLISH FLOOR TILE (UNIT 119 ONLY)

D8 DEMOLISH SINK VANITIES, WALL CABINETS, MIRRORS, TOWEL AND TOILET PAPER HOLDERS, SOAP TRAYS, ETC AND

ALL FASTENERS OR ANCHORS

D9 DEMOLISH WALL TILE AND SUBSTRATE AND/OR BACKERBOARD.

D10 EXISTING LIGHT SHELF TO REMAIN - REFER TO ELECTRICAL

D11 DEMOLISH EXISTING WATER-DAMAGED WOOD PLANK ROOF DECK, HATCHED AREA INDICATES APPROXIMATE

EXTENTS OF KNOWN DAMAGE. ALL DETERIORATED OR WATER-DAMAGED DECK SHALL BE REMOVED, ADVISE

CONTRACT OFFICER IF DAMAGE AREA IS FOUND TO EXTEND BEYOND THE INDICATED EXTENTS.

D12 DEMOLISH WOOD SHELVING, BRACKETS, SUPPORTS, HOOKS, HANGERS, ANCHORS, ETC. INSIDE OF CLOSET. PATCH

HOLES.

D13 SAWCUT AND DEMOLISH CONCRETE FLOOR SLAB FOR EXTENTS REQUIRED TO DEMOLISH EXISTING UNDERSLAB PIPING AND INSTALL NEW WORK. HATCHED AREA INDICATES APPROXIMATE EXTENTS. REFER TO NEW WORK

DRAWINGS FOR PATCH AND REPAIR SCOPE.

D14 DEMOLISH PLASTER AND/OR GYPSUM BOARD WALL FINISHES BOTH SIDES OF WALL AND AS REQUIRED TO

DEMOLISH EXISTING ELECTRICAL AND PLUMBING, AND INSTALL NEW WORK.

D15 DEMOLISH EXISTING WALL FROM 42" AFF TO SLOPED CEILING

D16 DEMOLISH WALLCOVERING FROM FULL EXTENTS OF WALL

D17 DEMOLISH CLOSET IN CORRIDOR AND BEDROOM A INCLUDING WOOD SHELVING, DOORS, AND OTHER

COMPONENTS.

D18 DEMOLISH SURFACE-MOUNTED HOUSE NUMBERS. EXACT LOCATION MAY VARY AT EACH UNIT.

D19 DEMOLISH HOSE BRACKET

D20 DEMOLISH ANTENNA AND ASSOCIATED BRACKETS AND WIRING. PATCH AND REPAIR EXISTING FINISHES AS

REQUIRED. REFER TO ELECTRICAL FOR SCOPE OF SATELLITE DISH

D21 DEMOLISH CORRUGATED METAL PANEL HURRICANE SHUTTERS AND SUPPORTS AT TOP AND BOTTOM OF WALL.

PATCH AND REPAIR SUBSTRATES.

D22 DEMOLISH PLASTER AND/OR DRYWALL CEILING FINISH FOR EXTENTS INDICATED.

0*>�349*8

G*3*7&1�349*8

1/4" = 1' - 0" SCALE OF FEET

0'4' 4' 8'

1*G*3)

'-0

'-0

'-0

22'-10" 23'-7"

82'-6"

48'-6"

'-0

36'-1"

3' -0

'-0

3' -0

3'-0"

3'-0"

8' -0

9' -0

D103 SCALE 14" = 1'

A INTERIOR DOORS: DEMO INTERIOR DOORS AND HARDWARE. INTERIOR DOOR FRAMES SHALL REMAIN.

B EXTERIOR DOORS: DEMOLISH EXTERIOR DOOR AND HARDWARE. GENERAL CONTRACTOR TO EVALUATE CONDITION

OF FRAME AND ADVISE CONTRACT OFFICER. REFER TO KEYNOTES FOR SCOPE OF SCREEN DOORS.

C INTERIOR FINISHES SHALL BE CUT, TRENCHED, DEMOLISHED AS REQUIRED TO INSTALL NEW WORK. MINIMIZE

INTERIOR FINISH DEMO, UTILIZE DEMOLISHED CEILING AREA IN CORRIDOR FOR ACCESS TO ATTIC SPACE. FINISH DEMO SHALL BE CARRIED OUT BY MAKING CLEAN STRAIGHT CUTS IN FINISHES AND DEMOLISHING FINISHES WITHIN CUT AREAS. WALL AND CEILING FRAMING SHALL BE PRESERVED UN-DAMAGED. ALL DAMAGE RESULTING FROM DEMO WORK SHALL BE PATCHED AND REPAIRED TO MATCH ADJACENT WALL FINISH AND TEXTURE.

D FLOOR FINISHES: TERRAZZO FLOOR AND CONCRETE SLAB SUBSTRATE SHALL BE CUT, TRENCED, DEMOLISHED AS REQUIRED TO INSTALL NEW WORK. MINIMIZE FLOOR SLAB DEMO. LOCATE UNDERSLAB PIPING AND OTHER UTILITIES BY NON-DESTRUCTIVE MEANS PRIOR TO BEGINNING DEMO. SAWCUT TERRAZZO FINISH AND CONCRETE

SLAB IN CLEAN STRAIGHT AND ORTHOGONAL LINES.

E INTERIOR WOOD TRIM: BASE TRIM AND DOOR TRIM SHALL BE DEMOLISHED ONLY WHERE REQUIRED TO CARRY OUT NEW WORK. SALVAGE TRIM FOR REUSE. PROVIDE NEW TRIM WHERE REUSE OF SALVAGED TRIM IS NOT

POSSIBLE (PROFILE TO MATCH EXISTING TRIM)

F WINDOWS: EXTERIOR WINDOWS NIC. PROTECT WINDOWS AND HURRICANE SHUTTERS FROM DAMAGE DURING

THE COURSE OF CONSTRUCTION.

G EXTERIOR WOOD SIDING: DEMO EXISTING WOOD SIDING AND FASTENERS IN ENTIRETY. REMOVE BUILDING PAPER OR BUILDING WRAP IF PRESENT. ADVISE CONTRACT OFFICER OF DETERIORATED SUBSTRATE AND AWAIT DIRECTION

ON REPLACEMENT MATERIALS AND METHODS.

H WINDOWS SHADES/BLINDS: DEMO LOUVRE BLINDS, VALENCES, HANGERS AND ALL BRACKETS AND ANCHORS AT EACH WINDOW AND SLIDING DOOR IN EACH UNIT. PATCH AND REPAIR ANY DAMAGE MADE BY REMOVAL OF

BRACKETS, ANCHORS, OR OTHER COMPONENTS TO MATCH ADJACENT EXISTING SURFACES.

DR01 DEMOLISH ASPHALT ROLL-ROOFING, UNDERLAYMENT, EDGE TRIMS, FASCIAS AND DRIP EDGES. DETERIORATED SUBSTRATES OR SHEATHING SHALL BE REMOVED AND REPLACED. ADVISE CONTRACT OFFICER OF DETERIORATED

MATERIALS AND AWAIT DIRECTION ON REPLACEMENT MATERIALS AND METHODS.

DR02

DEMOLISH ASPHALT ROLL ROOFING AND SUBSTRATE AT GABLE ENDS, UNIT #119 ONLY.

DR03 AT UNIT #119 DEMOLISH ASPHALT SHINGLE ROOFING FROM SLOPED ROOF AREA. DEMOLISH UNDERLAYMENT, EDGE TRIMS, FASCIAS AND DRIP EDGES. DETERIORATED SUBSTRATES OR SHEATHING SHALL BE REMOVED AND REPLACED. ADVISE CONTRACT OFFICER OF DETERIORATED MATERIALS AND AWAIT DIRECTION ON REPLACEMENT

MATERIALS AND METHODS.

DR04 AT UNITS #120 AND #124 DEMOLISH ASPHALT ROLL-ROOFING FROM LOW SLOPED ROOF AREA. DEMOLISH UNDERLAYMENT, EDGE TRIMS, FASCIAS AND DRIP EDGES. DETERIORATED SUBSTRATES OR SHEATHING SHALL BE REMOVED AND REPLACED. ADVISE CONTRACT OFFICER OF DETERIORATED MATERIALS AND AWAIT DIRECTION

ON REPLACEMENT MATERIALS AND METHODS.

DR05 REMOVE AND SALVAGE EXISTING ROOF VENTILATORS FOR RE-INSTALLATION

DR06 DEMOLISH ROOF AND STACK VENTS

SL

O

PE

SL

O

PE

G*3*7&1�349*8

1/4" = 1' - 0" SCALE OF FEET

0'4' 4' 8'

0*>�349*8

D102 SCALE 18" = 1'

D102 SCALE 18" = 1'

D102 SCALE 18" = 1'

D102 SCALE 18" = 1'

A INTERIOR DOORS: DEMO INTERIOR DOORS AND HARDWARE. INTERIOR DOOR FRAMES SHALL REMAIN.

B EXTERIOR DOORS: DEMOLISH EXTERIOR DOOR AND HARDWARE. GENERAL CONTRACTOR TO EVALUATE CONDITION

OF FRAME AND ADVISE CONTRACT OFFICER. REFER TO KEYNOTES FOR SCOPE OF SCREEN DOORS.

C INTERIOR FINISHES SHALL BE CUT, TRENCHED, DEMOLISHED AS REQUIRED TO INSTALL NEW WORK. MINIMIZE

INTERIOR FINISH DEMO, UTILIZE DEMOLISHED CEILING AREA IN CORRIDOR FOR ACCESS TO ATTIC SPACE. FINISH DEMO SHALL BE CARRIED OUT BY MAKING CLEAN STRAIGHT CUTS IN FINISHES AND DEMOLISHING FINISHES WITHIN CUT AREAS. WALL AND CEILING FRAMING SHALL BE PRESERVED UN-DAMAGED. ALL DAMAGE RESULTING FROM DEMO WORK SHALL BE PATCHED AND REPAIRED TO MATCH ADJACENT WALL FINISH AND TEXTURE.

D FLOOR FINISHES: TERRAZZO FLOOR AND CONCRETE SLAB SUBSTRATE SHALL BE CUT, TRENCED, DEMOLISHED AS REQUIRED TO INSTALL NEW WORK. MINIMIZE FLOOR SLAB DEMO. LOCATE UNDERSLAB PIPING AND OTHER UTILITIES BY NON-DESTRUCTIVE MEANS PRIOR TO BEGINNING DEMO. SAWCUT TERRAZZO FINISH AND CONCRETE

SLAB IN CLEAN STRAIGHT AND ORTHOGONAL LINES.

E INTERIOR WOOD TRIM: BASE TRIM AND DOOR TRIM SHALL BE DEMOLISHED ONLY WHERE REQUIRED TO CARRY OUT NEW WORK. SALVAGE TRIM FOR REUSE. PROVIDE NEW TRIM WHERE REUSE OF SALVAGED TRIM IS NOT

POSSIBLE (PROFILE TO MATCH EXISTING TRIM)

F WINDOWS: EXTERIOR WINDOWS NIC. PROTECT WINDOWS AND HURRICANE SHUTTERS FROM DAMAGE DURING

THE COURSE OF CONSTRUCTION.

G EXTERIOR WOOD SIDING: DEMO EXISTING WOOD SIDING AND FASTENERS IN ENTIRETY. REMOVE BUILDING PAPER OR BUILDING WRAP IF PRESENT. ADVISE CONTRACT OFFICER OF DETERIORATED SUBSTRATE AND AWAIT DIRECTION

ON REPLACEMENT MATERIALS AND METHODS.

H WINDOWS SHADES/BLINDS: DEMO LOUVRE BLINDS, VALENCES, HANGERS AND ALL BRACKETS AND ANCHORS AT EACH WINDOW AND SLIDING DOOR IN EACH UNIT. PATCH AND REPAIR ANY DAMAGE MADE BY REMOVAL OF

BRACKETS, ANCHORS, OR OTHER COMPONENTS TO MATCH ADJACENT EXISTING SURFACES.

D1 DEMOLISH ALUMINUM-FRAMED SCREENWALL SYSTEM

D2 DEMOLISH CONCRETE CONDENSING UNIT PAD

D3 DEMOLISH ROOF OVERHANG SOFFITS AND VENTS

D4 DEMOLISH CLOSET SLIDING DOORS AND TRACKS

D5 DEMOLISH KITCHEN CABINETS

D6 DEMOLISH KITCHEN APPLIANCES

D7 DEMOLISH FLOOR TILE (UNIT 119 ONLY)

D8 DEMOLISH SINK VANITIES, WALL CABINETS, MIRRORS, TOWEL AND TOILET PAPER HOLDERS, SOAP TRAYS, ETC AND

ALL FASTENERS OR ANCHORS

D9 DEMOLISH WALL TILE AND SUBSTRATE AND/OR BACKERBOARD.

D10 EXISTING LIGHT SHELF TO REMAIN - REFER TO ELECTRICAL

D11 DEMOLISH EXISTING WATER-DAMAGED WOOD PLANK ROOF DECK, HATCHED AREA INDICATES APPROXIMATE

EXTENTS OF KNOWN DAMAGE. ALL DETERIORATED OR WATER-DAMAGED DECK SHALL BE REMOVED, ADVISE

CONTRACT OFFICER IF DAMAGE AREA IS FOUND TO EXTEND BEYOND THE INDICATED EXTENTS.

D12 DEMOLISH WOOD SHELVING, BRACKETS, SUPPORTS, HOOKS, HANGERS, ANCHORS, ETC. INSIDE OF CLOSET. PATCH

HOLES.

D13 SAWCUT AND DEMOLISH CONCRETE FLOOR SLAB FOR EXTENTS REQUIRED TO DEMOLISH EXISTING UNDERSLAB PIPING AND INSTALL NEW WORK. HATCHED AREA INDICATES APPROXIMATE EXTENTS. REFER TO NEW WORK

DRAWINGS FOR PATCH AND REPAIR SCOPE.

D14 DEMOLISH PLASTER AND/OR GYPSUM BOARD WALL FINISHES BOTH SIDES OF WALL AND AS REQUIRED TO

DEMOLISH EXISTING ELECTRICAL AND PLUMBING, AND INSTALL NEW WORK.

D15 DEMOLISH EXISTING WALL FROM 42" AFF TO SLOPED CEILING

D16 DEMOLISH WALLCOVERING FROM FULL EXTENTS OF WALL

D17 DEMOLISH CLOSET IN CORRIDOR AND BEDROOM A INCLUDING WOOD SHELVING, DOORS, AND OTHER

COMPONENTS.

D18 DEMOLISH SURFACE-MOUNTED HOUSE NUMBERS. EXACT LOCATION MAY VARY AT EACH UNIT.

D19 DEMOLISH HOSE BRACKET

D20 DEMOLISH ANTENNA AND ASSOCIATED BRACKETS AND WIRING. PATCH AND REPAIR EXISTING FINISHES AS

REQUIRED. REFER TO ELECTRICAL FOR SCOPE OF SATELLITE DISH

D21 DEMOLISH CORRUGATED METAL PANEL HURRICANE SHUTTERS AND SUPPORTS AT TOP AND BOTTOM OF WALL.

PATCH AND REPAIR SUBSTRATES.

D22 DEMOLISH PLASTER AND/OR DRYWALL CEILING FINISH FOR EXTENTS INDICATED.

1/4" = 1' - 0" SCALE OF FEET

0'4' 4' 8'

0*>�349*8

G*3*7&1�349*8

OPEN

TO

BEYOND

OPEN

TO

BEYOND

A101

1 FLOOR PLAN

SLAB REPAIR AND INFILL DETAIL

A101

2 CONCRETE HVAC PAD DETAIL

A101

SCALE: B

KEY NOTES

GENERAL NOTES

SCALE: B

SCALE: A

WINDOW SHADE SCHEDULE

A PROTECT ALL EXISTING FINISHES FROM DAMAGE DURING THE COURSE OF THE WORK.

PROVIDE PROTECTIVE FLOOR COVERINGS FOR FULL EXTENT OF INTERIOR FINISH FLOORS.

PROTECT CABINETS, APPLIANCES, FIXTURES AND OTHER EXISTING-TO-REMAIN ITEMS

WITH PLASTIC OR OTHER PROTECTIVE MEANS.

B INTERIOR PAINTING SCOPE:- EXISTING PAINTED INTERIOR SURFACES SHALL BE PAINTED.

INCLUDING BUT NOT LIMITED TO WALLS, CEILINGS, TRIM, DOORS, CLOSET INTERIORS

AND CLOSET DOORS, AND EXPOSED WOOD ROOF DECK PLANKS.- PREPARE ALL

SURFACES BY REMOVING EXISTING FASTENERS, ANCHORS OR OTHER ITEMS. FILL AND

PATCH ALL HOLES AND CRACKS. SCRAPE AND REMOVE FLAKING OR UNADHERED PAINT.-

REFER TO PAINTING SPECIFICATION FOR PAINT SYSTEMSPAINT COLOR SELECTIONS:-

PNT-1: CEILINGS- PNT-2: INTERIOR WALLS- PNT-3: CLOSETS AND SHELVING INTERIORS

AND TRIM

C DIMENSIONS PROVIDED ARE APPROXIMATE. ALL DIMENSIONS SHALL BE FIELD VERIFIED

BY CONTRACTOR.

D NEW INTERIOR PARTITION ASSEMBLY SHALL BE 2X4 WOOD FRAMING WITH 1/2"

DRYWALL EACH SIDE.

1 NEW CONCRETE PAD FOR CONDENSING UNIT. COORDINATE SIZE WITH MANUFACTURER

RECOMMENDATIONS

2 NEW VENTED FIBER CEMENT SOFFIT PANELS, DASHED LINE INDICATES EXTENT OF

VENTED PANELS.

3 NEW TERRAZZO FINISH ON NEW SLAB INFILL

4 PROVIDE HURRICANE PANELING SYSTEM MATCHING EXISTING DEMOLISHED SYSTEM.

REFER TO NOTES ON A301.

5 REPLACE WOOD ROOF DECK PLANKS WITH NEW PLANKS OF SAME DIMENSION

6 DEMOLISH AND REPLACE EXISTING ICLOSET DOORS, HARDWARE AND SLIDING TRACKS

AT EACH CLOSET. REPLACE WITH BI-FOLD DOORS AND ADD SHELF AND POLE AT EACH.

7 PATCH EXISTING WALL AS REQUIRED FOR INSTALLATION OF ELECTRICAL PANEL (REFER

TO ELECTRICAL)

8 WALL MOUNTED FIRE EXTINGUISHER -- REFER TO SPECIFICATIONS

9 REFER TO HARDWARE SET 10 IN SPECIFICATION SECTION 08 71 00 FOR CLOSET

HARDWARE

10 24x24 PLYWOOD ACCESS PANEL (PTD) IN DRYWALL CEILING - COORDINATE FINAL

LOCATION WITH WORK IN ATTIC - HEADERS TO MATCH BOTTOM CORD OF ROOF TRUSS -

1x3 WOOD TRIM (PTD) WITH 1/2" FOAM TAPE ALL SIDES

11 DRYWALL CEILING FINISH (PAINTED) MATCH EXISTING CEILING HEIGHT AND TIE INTO

EXISTING BULKHEAD IN LIVING ROOM (01)

12 DRYWALL CEILING FINISH (PAINTED) MATCH EXISTING CEILING SLOPE

WS-1 ROLLER WINDOW SHADE -- REFER TO SPECIFICATIONS

Pantry

HVAC

Closet

W

D

WH

A.H.U.

SCREENED

PORCH

LIVING

ROOM

CAR

PORT

KITCHEN

BATHROOM

POWDER

ROOM

BEDROOM

A

BEDROOM

B

BEDROOM

C

04a

CLOSET

CORRIDOR

03a

LAUNDRY

01a

05a

03d

04a

04b

04c

03c

03b

01b

03a

XX-XX 1

A401

XX-XX 4

0905b

XX-XX 4

SW-1

XX-XX 6

XX-XX 6

SAND, PATCH & APPLY EPOXY

COAT OVER SLAB IN COLOR TO

MATCH EXISTING @ PORCH

RESTORE EXIST TERRAZZO FLOORING

@ ALL LOC. U.O.N. REMOVE SEALER,

FINE GRIND, ADD GROUT AS NEEDED,

POLISH 200 GRIT AND APPLY NEW

REPLACE EXIST

SLABS IN-KIND @

ALL ENTRIES (TYP)

REBUILD CLOSET WALL TO

MEET 36" MIN REQ

CLEARANCE. RELOCATE

DOORS 01b AND 03c AS REQ

36" MIN

A201

A201

A201

A201

2' -9

NEW TERRAZZO FINISH

CONCRETE SLAB INFILL

0' -4

0'-4"

3" MIN. #57 STONE

4' x4' WELDED WIRE

MESH REINFORCING

AT MID-POINT OF SLAB

3" MIN. #57 STONE

0' -6

0' -4

HATCHED AREA INDICATES APPROXIMATE EXTENTS OF

NEW TERRAZZO FLOOR FINISH. COORDINATE WITH

EXTENTS OF REQUIRED SLAB DEMOLITION AND INFILL

HATCHED AREA INDICATES APPROXIMATE EXTENTS OF NEW

CEILING FINISH. COORDINATE WITH EXTENTS OF REQUIRED

CEILING DEMO.

A101

01a

05a

03d

04a

04b

04c

03c

03b

03a

SCALE: BA101 A101A101

A PROTECT ALL EXISTING FINISHES FROM DAMAGE DURING THE COURSE OF THE

WORK. PROVIDE PROTECTIVE FLOOR COVERINGS FOR FULL EXTENT OF

INTERIOR FINISH FLOORS. PROTECT CABINETS, APPLIANCES, FIXTURES AND

OTHER EXISTING-TO-REMAIN ITEMS WITH PLASTIC OR OTHER PROTECTIVE

MEANS.

B INTERIOR PAINTING SCOPE:

- EXISTING PAINTED INTERIOR SURFACES SHALL BE PAINTED. INCLUDING BUT

NOT LIMITED TO WALLS, CEILINGS, TRIM, DOORS, CLOSET INTERIORS AND

CLOSET DOORS, AND EXPOSED WOOD ROOF DECK PLANKS.

- PREPARE ALL SURFACES BY REMOVING EXISTING FASTENERS, ANCHORS OR

OTHER ITEMS. FILL AND PATCH ALL HOLES AND CRACKS. SCRAPE AND REMOVE

FLAKING OR UNADHERED PAINT.

- REFER TO PAINTING SPECIFICATION FOR PAINT SYSTEMS

PAINT COLOR SELECTIONS:

- PNT-1: CEILINGS

- PNT-2: INTERIOR WALLS

- PNT-3: CLOSETS AND SHELVING INTERIORS AND TRIM

C DIMENSIONS PROVIDED ARE APPROXIMATE. ALL DIMENSIONS SHALL BE FIELD

VERIFIED BY CONTRACTOR.

D NEW INTERIOR PARTITION ASSEMBLY SHALL BE 2X4 WOOD FRAMING WITH

1/2" DRYWALL EACH SIDE.

1 NEW CONCRETE PAD FOR CONDENSING UNIT. COORDINATE SIZE WITH

MANUFACTURER RECOMMENDATIONS

2 NEW VENTED FIBER CEMENT SOFFIT PANELS, DASHED LINE INDICATES EXTENT

OF VENTED PANELS.

3 NEW TERRAZZO FINISH ON NEW SLAB INFILL

4 PROVIDE HURRICANE PANELING SYSTEM MATCHING EXISTING DEMOLISHED

SYSTEM. REFER TO NOTES ON A301.

5 REPLACE WOOD ROOF DECK PLANKS WITH NEW PLANKS OF SAME DIMENSION

6 DEMOLISH AND REPLACE EXISTING IN-KIND CLOSET DOORS, HARDWARE AND

SLIDING TRACKS AT EACH CLOSET. REFER TO 2/A401 DETAILS FOR SCOPE AND

ARRANGEMENT.

7 PATCH EXISTING WALL AS REQUIRED FOR INSTALLATION OF ELECTRICAL PANEL

(REFER TO ELECTRICAL)

8 WALL MOUNTED FIRE EXTINGUISHER -- REFER TO SPECIFICATIONS

9 REFER TO HARDWARE SET 10 IN SPECIFICATION SECTION 08 71 00 FOR CLOSET

HARDWARE

2X4 STUD WALL,

FLOOR TO ROOF

DECK PT SILL PLATE,

LEAD BOTH SIDES

WITH FIBER CEMENT

PANEL CLADDING.

NOTE:

NEW WORK AT UNIT

#119 ONLY.

03a

LAUNDRY

PORCH

SCREENED

1/4" = 1' - 0" SCALE OF FEET

0'4' 4' 8'

1 1/2" = 1' - 0" SCALE OF FEET

0'1' 1'6"

0*>�349*8

G*3*7&1�349*8

1*G*3)

A2

A201 A201

A2

0905b

02a

02b

SCALE: BSCALE: A

SCALE: A

B

A

<.3)4<�8-&)*�8(-*):1*

WS-1 ROLLER WINDOW SHADE -- REFER TO SPECIFICATIONS

WS-2L

VERTICAL LOUVER BLINDS -- CONTROL ON RIGHT; DRAW/ STACK ONE

WAY, STACK LEFT; LENGTH TO BE WINDOW OPENING PLUS 1 1/2" --

REFER TO VERTICAL LOUVER BLIND SPECIFICATION

WS-2R

VERTICAL LOUVER BLINDS -- CONTROL ON LEFT; DRAW/ STACK ONE WAY,

STACK RIGHT; LENGTH TO BE WINDOW OPENING PLUS 1 1/2" -- REFER TO

VERTICAL LOUVER BLIND SPECIFICATION

11/21/2022

2' -9

NEW TERRAZZO FINISH

CONCRETE SLAB INFILL

0' -4

0'-4"

3" MIN. #57 STONE

4' x4' WELDED WIRE

MESH REINFORCING

AT MID-POINT OF SLAB

3" MIN. #57 STONE

0' -6

0' -4

HATCHED AREA INDICATES APPROXIMATE EXTENTS OF

NEW TERRAZZO FLOOR FINISH. COORDINATE WITH

EXTENTS OF REQUIRED SLAB DEMOLITION AND INFILL

HATCHED AREA INDICATES APPROXIMATE EXTENTS OF NEW

CEILING FINISH. COORDINATE WITH EXTENTS OF REQUIRED

CEILING DEMO.

A101

01a

05a

03d

04a

04b

04c

03c

03b

03a

SCALE: BA101 A101A101

A PROTECT ALL EXISTING FINISHES FROM DAMAGE DURING THE COURSE OF THE

WORK. PROVIDE PROTECTIVE FLOOR COVERINGS FOR FULL EXTENT OF

INTERIOR FINISH FLOORS. PROTECT CABINETS, APPLIANCES, FIXTURES AND

OTHER EXISTING-TO-REMAIN ITEMS WITH PLASTIC OR OTHER PROTECTIVE

MEANS.

B INTERIOR PAINTING SCOPE:

- EXISTING PAINTED INTERIOR SURFACES SHALL BE PAINTED. INCLUDING BUT

NOT LIMITED TO WALLS, CEILINGS, TRIM, DOORS, CLOSET INTERIORS AND

CLOSET DOORS, AND EXPOSED WOOD ROOF DECK PLANKS.

- PREPARE ALL SURFACES BY REMOVING EXISTING FASTENERS, ANCHORS OR

OTHER ITEMS. FILL AND PATCH ALL HOLES AND CRACKS. SCRAPE AND REMOVE

FLAKING OR UNADHERED PAINT.

- REFER TO PAINTING SPECIFICATION FOR PAINT SYSTEMS

PAINT COLOR SELECTIONS:

- PNT-1: CEILINGS

- PNT-2: INTERIOR WALLS

- PNT-3: CLOSETS AND SHELVING INTERIORS AND TRIM

C DIMENSIONS PROVIDED ARE APPROXIMATE. ALL DIMENSIONS SHALL BE FIELD

VERIFIED BY CONTRACTOR.

D NEW INTERIOR PARTITION ASSEMBLY SHALL BE 2X4 WOOD FRAMING WITH

1/2" DRYWALL EACH SIDE.

1 NEW CONCRETE PAD FOR CONDENSING UNIT. COORDINATE SIZE WITH

MANUFACTURER RECOMMENDATIONS

2 NEW VENTED FIBER CEMENT SOFFIT PANELS, DASHED LINE INDICATES EXTENT

OF VENTED PANELS.

3 NEW TERRAZZO FINISH ON NEW SLAB INFILL

4 PROVIDE HURRICANE PANELING SYSTEM MATCHING EXISTING DEMOLISHED

SYSTEM. REFER TO NOTES ON A301.

5 REPLACE WOOD ROOF DECK PLANKS WITH NEW PLANKS OF SAME DIMENSION

6 DEMOLISH AND REPLACE EXISTING IN-KIND CLOSET DOORS, HARDWARE AND

SLIDING TRACKS AT EACH CLOSET. REFER TO 2/A401 DETAILS FOR SCOPE AND

ARRANGEMENT.

7 PATCH EXISTING WALL AS REQUIRED FOR INSTALLATION OF ELECTRICAL PANEL

(REFER TO ELECTRICAL)

8 WALL MOUNTED FIRE EXTINGUISHER -- REFER TO SPECIFICATIONS

9 REFER TO HARDWARE SET 10 IN SPECIFICATION SECTION 08 71 00 FOR CLOSET

HARDWARE

2X4 STUD WALL,

FLOOR TO ROOF

DECK PT SILL PLATE,

LEAD BOTH SIDES

WITH FIBER CEMENT

PANEL CLADDING.

NOTE:

NEW WORK AT UNIT

#119 ONLY.

03a

LAUNDRY

PORCH

SCREENED

1/4" = 1' - 0" SCALE OF FEET

0'4' 4' 8'

1 1/2" = 1' - 0" SCALE OF FEET

0'1' 1'6"

0*>�349*8

G*3*7&1�349*8

1*G*3)

A2

A201 A201

A2

0905b

02a

02b

SCALE: BSCALE: A

SCALE: A

B

A

<.3)4<�8-&)*�8(-*):1*

WS-1 ROLLER WINDOW SHADE -- REFER TO SPECIFICATIONS

WS-2L

VERTICAL LOUVER BLINDS -- CONTROL ON RIGHT; DRAW/ STACK ONE

WAY, STACK LEFT; LENGTH TO BE WINDOW OPENING PLUS 1 1/2" --

REFER TO VERTICAL LOUVER BLIND SPECIFICATION

WS-2R

VERTICAL LOUVER BLINDS -- CONTROL ON LEFT; DRAW/ STACK ONE WAY,

STACK RIGHT; LENGTH TO BE WINDOW OPENING PLUS 1 1/2" -- REFER TO

VERTICAL LOUVER BLIND SPECIFICATION

11/21/2022

A111

A111

WS-1

WS-1

WS-1

W S-

W

S-

WS-1 WS-1WS-1 WS-1

WS-1 WS-1WS-1 WS-1 WS-1

11'-6"

'-9

HATCHED AREA INDICATES APPROXIMATE EXTENTS OF

NEW TERRAZZO FLOOR FINISH. COORDINATE WITH

EXTENTS OF REQUIRED SLAB DEMOLITION AND INFILL

HATCHED AREA INDICATES APPROXIMATE EXTENTS OF NEW

CEILING FINISH. COORDINATE WITH EXTENTS OF REQUIRED

CEILING DEMO.

A102 SCALE 14" = 1'

A PROTECT ALL EXISTING FINISHES FROM DAMAGE DURING THE COURSE OF THE

WORK. PROVIDE PROTECTIVE FLOOR COVERINGS FOR FULL EXTENT OF

INTERIOR FINISH FLOORS. PROTECT CABINETS, APPLIANCES, FIXTURES AND

OTHER EXISTING-TO-REMAIN ITEMS WITH PLASTIC OR OTHER PROTECTIVE

MEANS.

B INTERIOR PAINTING SCOPE:

- EXISTING PAINTED INTERIOR SURFACES SHALL BE PAINTED. INCLUDING BUT

NOT LIMITED TO WALLS, CEILINGS, TRIM, DOORS, CLOSET INTERIORS AND

CLOSET DOORS, AND EXPOSED WOOD ROOF DECK PLANKS.

- PREPARE ALL SURFACES BY REMOVING EXISTING FASTENERS, ANCHORS OR

OTHER ITEMS. FILL AND PATCH ALL HOLES AND CRACKS. SCRAPE AND REMOVE

FLAKING OR UNADHERED PAINT.

- REFER TO PAINTING SPECIFICATION FOR PAINT SYSTEMS

PAINT COLOR SELECTIONS:

- PNT-1: CEILINGS

- PNT-2: INTERIOR WALLS

- PNT-3: CLOSETS AND SHELVING INTERIORS AND TRIM

C DIMENSIONS PROVIDED ARE APPROXIMATE. ALL DIMENSIONS SHALL BE FIELD

VERIFIED BY CONTRACTOR.

D NEW INTERIOR PARTITION ASSEMBLY SHALL BE 2X4 WOOD FRAMING WITH

1/2" DRYWALL EACH SIDE.

1 NEW CONCRETE PAD FOR CONDENSING UNIT. COORDINATE SIZE WITH

MANUFACTURER RECOMMENDATIONS

2 NEW VENTED FIBER CEMENT SOFFIT PANELS, DASHED LINE INDICATES EXTENT

OF VENTED PANELS.

3 NEW TERRAZZO FINISH ON NEW SLAB INFILL

4 PROVIDE NEW HURRICANE PANELING SYSTEM MATCHING EXISTING

DEMOLISHED SYSTEM. PROVIDE ALL REQUIRED COMPONENTS INCLUDING BUT

NOT LIMITED TO 0.050 THICK, 2" CORRUGATED ALUMINUM PANELS AND

POWDERCOATED ALUMINUM 2" 'H' HEADER TRACK AND STUDDED ANGLE

BOTTOM TRACK, AND ALL REQUIRED FASTENERS.

5 REPLACE WOOD ROOF DECK PLANKS WITH NEW PLANKS OF SAME DIMENSION

6 DEMOLISH AND REPLACE EXISTING IN-KIND CLOSET DOORS, HARDWARE AND

SLIDING TRACKS AT EACH CLOSET. REFER TO 2/A401 DETAILS FOR SCOPE AND

ARRANGEMENT.

7 PATCH EXISTING WALL AS REQUIRED FOR INSTALLATION OF ELECTRICAL PANEL

(REFER TO ELECTRICAL)

8 WALL MOUNTED FIRE EXTINGUISHER -- REFER TO SPECIFICATIONS

9 REFER TO HARDWARE SET 10 IN SPECIFICATION SECTION 08 71 00 FOR CLOSET

HARDWARE

10 24x24 PLYWOOD ACCESS PANEL (PTD) IN DRYWALL CEILING - COORDINATE

FINAL LOCATION WITH WORK IN ATTIC - HEADERS TO MATCH BOTTOM CORD

OF ROOF TRUSS - 1x3 WOOD TRIM (PTD) WITH 1/2" FOAM TAPE ALL SIDES

0*>�349*8

G*3*7&1�349*8

1/4" = 1' - 0" SCALE OF FEET

0'4' 4' 8'

1*G*3)

AREA OF TAPERED INSULATION

ROOF ASSEMBLY TYPE

STANDING SEAM METAL ROOFING

SYSTEM

STANDING SEAM

METAL ROOFING

ROOFING UNDERLAYMENT

32" APA RATED STRUCTURAL

1 SHEATHING

2X8 OVERBUILD

DRILL LINE OF 4" HOLES @ 2'-0"

O.C. FROM EAVE TO RIDGE IN

EACH RAFTER BAY TO PROVIDE

VENTILATION

EXISTING ROOF RAFTER

EXISTING ROOF SHEATHING

MATCH EXISTING SLOPE

NEW 2X8 RAFTER OVERBUILD.

ALIGNED WITH EXISTING RAFTER.

INSECT SCREEN

SBS MODIFIED BITUMEN

ROOFING SYSTEM

2" COVERBOARD

1" INSULATION BASE LAYER,

WITH 18" TAPERED

INSULATION OVERLAY

EXISTING WOOD

ROOF DECK

8" TO 12" SLOPE

SLO

PE

SLO

PE

SLOPE

SLOPE

1 ROOF OVERBUILD FOR FULL EXTENT OF RA-1. INSTALL NEW 2X8 RAFTERS OVER

EXSTING ROOF SHEATHING. ALIGN EACH NEW RAFTER W/EXISTING RAFTER

BELOW. FOR FULL EXTENT OF ROOF ASSEMBLY RA-1 INSTALL 2X8 RAFTER AND

SHEATHING OVERBUILD. TIE NEW RAFTERS TO EXISTING WITH GALVANIZED

METAL TIE PLATE. DRILL GRID OF 4" HOLES AT 2'-0" O.C. IN EXISTING ROOF

SHEATHING ACROSS ENTIRE ROOF AREA TO PROVIDE VENTILATION.

2 REINSTALL EXISTING ROOF VENTILATORS AND FLASHING INTO STANDING SEAM

METAL ROOF

3 ROOF AND STACK VENTS FLASHED INTO STANDING SEAM METAL ROOF -- REFER

TO PLUMBING DRAWINGS

4 LOW PROFILE ROOF VENTS FLASHED INTO STANDING SEAM METAL ROOF --

CENTER IN STANDING SEAM METAL PANELS -- REFER TO MECHANCIAL

DRAWINGS

SL

O

PE

SLOPE

SL

O

PE

SLO

PE

SLO

PE

A DOCUMENT EXISTING CONDITION OF ROOF RAFTERS AND ROOF SHEATHING

AFTER DEMOLITION OF EXISTING ROOFING MATERIOALS AND PRIOR TO

CARRYING OUT NEW WORK. PROVIDE DOCUMENTATION OF EXISTING

CONDITIONS TO CONTRACT OFFICER FOR REVIEW AND CONFIRMATION OF NEW

WORK DESIGN AND APPROACH.

B ROOF ASSEMLBY RA-2 TO HAVE 1/8-INCH PER FOOT SLOPE WITH TAPERED

INSULATION ON TOP OF 1-INCH BASE LAYER

SLOPE

0*>�349*8

G*3*7&1�349*8

1*G*3)

A103 SCALE: B A103 SCALE: B

1/4" = 1' - 0" SCALE OF FEET

0'4' 4' 8'

1 1/2" = 1' - 0" SCALE OF FEET

0'1' 1'6" B

A

A103 SCALE: A

2" COVERBOARD

1" INSULATION

MODIFIED BITUMEN

ROOFING SYSTEM

PT WOOD BLOCKING

METAL DRIP EDGE

W/CLEAT

EXISTING ROOF

CONSTRUCTION

PT WOOD BLOCKING

FIBER CEMENT

FASCIA TRIM, 6", PAINTED.

VENTED FIBER CEMENT

SOFFIT PANEL, PAINTED

SECURE INSECT SCREEN

TO TOP SIDE OF SOFFIT

VENT CONTINUOUS

2" COVERBOARD

1" INSULATION

MODIFIED BITUMEN

ROOFING SYSTEM

PT WOOD BLOCKING

METAL DRIP EDGE

W/CLEAT

EXISTING ROOF

CONSTRUCTION

FIBER CEMENT FASCIA

TRIM, PAINTED

32" APA RATED STRUCTURAL

PLYWOOD SHEATHING

STANDING SEAM

METAL ROOF SYSTEM

METAL FLASHING TRIM

W/DRIP EDGE

MODIFIED BITUMEN

ROOFING SYSTEM

2" COVERBOARD

1" INSULATION

EXISTING ROOF DECK

ROOFING UNDERLAYMENT

2X8 RAFTER OVERBUILD, ALIGN

EACH NEW RAFTER W/EXISTING

ROOF RAFTER.

CUT STRIP IN EXISTING ROOF

SHEATHING. DRILL LINE OF 4"

HOLES AT 2'-0" O.C. FROM EAVE

TO RIDGE IN EACH RAFTER BAY

TO PROVIDE VENTILATION.

VENTED FIBER-CEMENT SOFFIT

PANEL. ENSURE CONTINUOUS

PATH OF AIRFLOW FROM SOFFIT

VENT TO RIDGE.

2X8, CONTINUOUS

TIE NEW AND EXISTING RAFTERS

TOGETHER WITH GALVANIZED

METAL SPLICE PLATE AT 4'-0" O.C.

INSECT SCREEN

STANDING SEAM METAL

ROOFING SYSTEM

METAL ROOF PANEL

SYSTEM GABLE-END TRIM

FIBER CEMENT FASCIA

TRIM, 8", PAINTED

ROOF UNDERLAYMENT

32" STRUCTURAL PLYWOOD

2X8 RAFTER OVERBUILD

PT WOOD SHIMS

FIBER CEMENT FASCIA

TRIM, 4", V.I.F

FIBER CEMENT VENTED

SOFFIT PANEL

TIE NEW AND EXISTING

RAFTERS TOGETHER WITH

GALVANIZED METAL SPLICE

PLATE AT 4'-0" O.C.

VENTED RIDGE CAP

STANDING SEAM

METAL ROOF SYSTEM

ROOFING UNDERLAYMENT

33" APA RATED STRUCTURAL 1

SHEATHING

NEW 2X8 RAFTER OVERBUILD,

ALIGNED WITH EXISTING RAFTER

EXISTING RAFTER AND

SHEATHING

TIE NEW AND EXISTING RAFTERS

TOGETHER WITH GALVANIZED

METAL SPLICE PLATE AT 4'-0" O.C.

1 1/2" = 1' - 0" SCALE OF FEET

0'1' 1'6"

A EXTERIOR PAINTING SCOPE:

▪ ALL EXISTING PAINTED EXTERIOR SURFACES SHALL BE PREPARED AND PAINTED

INCLUDING BUT NOT LIMITED TO CLADDING PANELS, WINDOW TRIM, DOOR

FRAMES, SOFFITS, ROOF OVERHANGS AND ROOF DECKS.

▪ PREPARE ALL SURFACES BY REMOVING EXISTING UNUSED FASTENERS,

ANCHORS OR OTHER ITEMS. REMOVE FLAKING OR UNADHERED PAINT. CLEAN

SURFACES IN ACCORDANCE WITH PAINT MANUFACTURERS

RECOMMENTATIONS.

▪ PAINT COLORS ARE TO BE DETERMINED:

▪ PNT-4: CLADDING/SIDING PANELS

▪ PNT-5: TRIM, SOFFITS, ROOF OVERHANGS

B WINDOWS WILL BE REPLACED BY SEPARATE CONTRACTOR UNDER SEPARATE

CONTRACT. PROTECT WINDOWS FROM DAMAGE DURING THE COURSE OF THE

WORK.

C AT SCREEN WALL SW-1, INSTALL 1" THICK PT BOARDS, BETWEEN OPENINGS, ON

EXTERIOR SIDE. BOARDS TO RUN FULL HEIGHT AND PLACED ON THE EXTERIOR

SIDE OF EXISTING METAL PANEL. PAINT TO MATCH FAÇADE.

1 UNIT #119 ONLY: FIBER CEMENT LAP SIDING IN GABLE END OVER

BUILDING-WRAP MEMBRANE AND SUBSTRATE

2 EXISTING WINDOW, TYPICAL

3 EXISTING FIBER CEMENT PANEL CLADDING, TYPICAL, PAINTED.

4 EXISTING MASONRY CLADDING, TYPICAL, PRESSURE WASH ALL FACES TO CLEAN.

5 EXISTING ROOF BEAMS AND OVERHANG, PAINTED.

SW-1

SW-2

0*>�349*8

G*3*7&1�349*8

1/4" = 1' - 0" SCALE OF FEET

0'4' 4' 8'

SCREEN

MESH

METAL

PANEL

R E

F.

S

C H

E D

U

LE

REF. SCHEDULE

1/

2" 5"

REF. SCHEDULE

R E

F.

S

C H

E D

U

LE

REF. SCHEDULE

R E

F.

S

C H

E D

U

LE

MATCH\EXTG

M A

TC

H

\E X

TG

M

A

TC

H \E

X

TG

REF. SCHEDULE

R E

F.

S

C H

E D

U

LE

L1 5"F

S L2

LOUVERLOUVER

SCREEN

MESH

REF. SCHEDULE

R E

F.

S

C H

E D

U

LE

L3

CLEAR GLASS

METAL

PANEL

DOOR SCHEDULE

NUMBER

DOOR FRAME DETAILS

FIRE RATING HDWRNEW/ EXIST FINISH

SIZE

NEW/ EXIST TYPE MAT'L JAMBWIDTH HEIGHT THICKNESS

PINE ISLAND 119, 120, 124

01a NEW F FIBERGLASS PF 2'-6" 6'-8" 1 3/8" EXIST - WOOD PAINTED H1 J1 S1 - 1

01b NEW L3 ALUM/GLASS PF 2'-6" 6'-8" - NEW - ALUM PAINTED - - - - -

03a NEW - FIBERGLASS - 2'-6" 6'-8" 1 3/8" EXIST - WOOD PAINTED - - - - - FIELD VERIFY DOOR WIDTH

03b NEW - FIBERGLASS - 5'-0" 6'-8" 1 3/8" EXIST - WOOD PAINTED - - - - -

03c NEW S ALUM - 2'-6" 6'-8" - NEW SW1 ALUM - - - - - 9 BY SCREEN ENCLOSURE MANUF

03d NEW S ALUM - 2'-6" 6'-7" - NEW SW3 ALUM - - - - - 9 BY SCREEN ENCLOSURE MANUF

04a NEW F FIBERGLASS PF 6'-0" 6'-8" 1 3/4" NEW - HM PAINTED H2 J2 - - 4

04b NEW F FIBERGLASS PF 6'-0" 6'-8" 1 3/4" NEW - HM PAINTED H2 J2 - - 4

04c NEW F FIBERGLASS PF 6'-0" 6'-8" 1 3/4" NEW - HM PAINTED H2 J2 - - 4

05a NEW L2 WOOD PAINTED 4'-0" 6'-8" 1 3/8" NEW - WOOD PAINTED - - - - -

05b NEW L1 WOOD PAINTED 2'-6" 6'-8" 1 3/8" NEW - WOOD PAINTED - - - - -

06 NEW L2 WOOD PAINTED 2'-0" 6'-8" 1 3/8" NEW - WOOD PAINTED - - - - 7

07 NEW L2 WOOD PAINTED 2'-6" 6'-8" 1 3/8" NEW - WOOD PAINTED - - - - 7

08 NEW L2 WOOD PAINTED 2'-6" 6'-8" 1 3/8" EXIST - WOOD PAINTED - - - - 8

09 NEW L2 WOOD PAINTED 2'-6" 6'-8" 1 3/8" EXIST - WOOD PAINTED - - - - 8

10 NEW L2 WOOD PAINTED 2'-6" 6'-8" 1 3/8" EXIST - WOOD PAINTED - - - - 8

TYPE MAT'L FINISH HEAD SILL COMMENTS

FULL-LITE DOOR

BI-FOLD W/ WOOD KNOB PULL

FIELD VERIFY DOOR WIDTH, ADD LOUVERS

08,09,10 CLO NEW L2 WOOD PAINTED 3'-6" 6'-8" 1 3/8" NEW - WOOD PAINTED - - - - - BI-FOLD BEDROOM CLOSET W/ WOOD KNOB PULL

3'-0" 2'-6" 2'-0"

3' -0

1'

-4

2' -6

WOOD VENEERED WALL

CABINET WITH ADJ

SHELF, TYPICAL

WOOD VENEERED BASE

CABINETS WITH ADJ

SHELF, TYPICAL

RECEPTACLE, REFER

TO ELECTRICAL.

1-1/2" SOLID SURFACE

COUNTERTOP AND

BACKSPLASH

1' -0

FILLER STRIP AS REQ.

PROVIDE BLOCKING

FOR WALL HUNG MW-01

RANGE

RW-02

MICROWAVE

MW-01

FILLER STRIP AS REQ.

RANGE

RW-02

KITCHEN

BATHROOM

PWDR ROOM

DW-01

RG-02

RF-01

026' -4

1'-111 4" 2'-0"

7' -9

7' -6

WOOD VENEERED

WALL CABINET W/

ADJ SHELF, TYP.

1'-3" 3'-0" 2'-0" 1'-6"

3' -0

1'

-4

2' -6

" RECEPTACLE MOUNTED

IN BACKSPLASH. REFER

TO ELECTRICAL.

1-1/2" SOLID SURFACE

COUNTERTOP AND

BACKSPLASH

DW-01

WOOD VENEERED BASE

CABINETS WITH ADJ

SHELF, TYPICAL

3' -6

1'-5"

FILLER STRIP AS

REQUIRED

1'-3"

FINISHED CABINET END

7'-9"

4' -3

EQ

EQ

4'-3" (VIF)

5' -7

1'

-6

7' -1

0"

(V

IF

0'-3"

REF HARDWARE SET 10 IN

SPECIFICATION SECTION 08 71 00

INTERMEDIATE SHELF - MATCH

EXISTING CLOSET SHELVING

CONSTRUCTION

0' -4

NEW SLIDING WOOD DOORS

0' -5

REF HARDWARE SET 10 IN

SPECIFICATION SECTION 08 71 00

A401 SCALE 12" = 1' A401 SCALE 12" = 1'

A401 SCALE 12" = 1'

A401 A401

A401 SCALE 12" = 1'

1 DASHED LINE INDICATES EXTENT OF NEW WALL TILE (WT-1) -- INSTALL TILE

OVER BACKERBOARD. MATCH EXISTING TILE HEIGHT OF +/- 46" AFF. VERIFY IN

FIELD. PROVIDE BULLNOSE UNITS AT ALL EDGES.

2 FIBERGLASS TUB/SHOWER, REF PLUMBING.

3 SINK VANITY CABINET WITH SOLID SURFACE TOP.

4 WALL CABINET, REFER TO SPECIFICATIONS

METAL BRACKETS

BELOW COUNTER,

TYP. OF (3)

KNEE WALL

BELOW

WOOD CLOSET ROD AND

BRACKETS - MATCH EXTG

CLOSET CONSTRUCTION

NEW PAINT-GRADE PLYWOOD

BOTTOM IN CLOSET ON 2X WOOD

FRAMING. MATCH HEIGHT A.F.F

OF EXISTING CLOSETS

1/2" = 1' - 0" SCALE OF FEET

0'1' 3'6" 2'1'

0*>�349*8

T1 METAL SHOWER CURTAIN ROD, EXPANDING TENSION, TYP.

T2 30" TOWEL BAR

T3 TOILET TISSUE HOLDER

T4 ROBE HOOK - MOUNT ON BACK OF DOOR

T5 12" TOWEL BAR

T6 MEDICINE CABINET WITH MIRROR, REFER TO SPECIFICATIONS

94.1*9�&((*8847.*8��7*+�85*(.+.(&9.438�

A401 SCALE 12" = 1'

ALIGN INTERIOR PARTITION

WITH EXISTING WALL - WOOD

BASE ON CORRIDOR SIDE TO

MATCH EXISTING PROFILE

MB

SS

1/4"=1'-0"

PLUMBING DEMOLITION PLAN - BLDG. 1191

PD101

DEMOLISH EXTERIOR SUPPLY AND WASTE PIPING ASSOCIATED WITH

EXISTING EQUIPMENT. WASTE PIPING SHALL BE REMOVED TO A POINT

FIVE FOOT OUTSIDE THE BUILDING OR AT THE YARD CLEANOUT.

WASTE PIPING SHALL BE TEMPORARILY CAPPED UNTIL MODIFICATION

PORTION OF THE PROJECT. SUPPLY PIPING SHALL BE REMOVED TO A

POINT FIVE FOOT OUTSIDE THE BUILDING AND BE TEMPORARILY

CAPPED UNTIL MODIFICATION PORTION OF THE PROJECT.

DEMOLISH ALL SUPPLY, WASTE AND VENT PIPING AND ASSOCIATED

APPURTENANCES WITH THE ROOM INCLUDING PIPING IN THE WALLS,

ABOVE THE CEILING AND BELOW SLAB (WALLS, CEILINGS AND SLAB

REMOVED BY OTHERS). WASTE AND VENT PIPING SHALL BE REMOVED

TO A POINT BELOW FLOOR/ABOVE CEILING. SUPPLY AND WASTE

PIPING SHALL BE REMOVED TO THE EXTERIOR. VENT PIPING SHALL BE

REMOVED TO THE VENT THRU ROOF. VENT THRU ROOF SHALL BE

REMOVED AND HOLE IN THE ROOF SHALL BE TEMPORARILY

CAPPED/PLUGGED UNTIL MODIFICATION PORTION OF THE PROJECT.

DEMOLISH ALL SUPPLY, WASTE AND VENT PIPING AND ASSOCIATED

APPURTENANCES CONNECTED TO THE WASHING MACHINE. SEE

DEMOLITION NOTE 2 FOR ADDITIONAL INFORMATION.

REMOVE AND LEGALLY DISPOSE OF EXISTING WATER HEATER,

ANCILLARY TRIM AND PIPING (SUPPLY AND DWV). SEE DEMOLITION

NOTE 2 FOR ADDITIONAL INFORMATION.

REMOVE AND LEGALLY DISPOSE OF EXISTING LAVATORY, ANCILLARY

TRIM AND PIPING (SUPPLY AND DWV). SEE DEMOLITION NOTE 2 FOR

ADDITIONAL INFORMATION.

REMOVE AND LEGALLY DISPOSE OF EXISTING KITCHEN SINK,

ANCILLARY TRIM AND PIPING (SUPPLY AND DWV). SEE DEMOLITION

NOTE 2 FOR ADDITIONAL INFORMATION.

REMOVE AND LEGALLY DISPOSE OF EXISTING TANK-TYPE WATER

CLOSET AND PIPING (SUPPLY AND DWV). SEE DEMOLITION NOTE 2 FOR

ADDITIONAL INFORMATION.

REMOVE AND DEMOLISH EXISTING SHOWER ASSEMBLY AND

ANCILLARY TRIM AND PIPING (SUPPLY AND DWV). SEE DEMOLITION

NOTE 2 FOR ADDITIONAL INFORMATION.

GENERAL NOTE:

DEMOLISH ALL HOT AND COLD WATER AND DWV PIPING THROUGHOUT

THE BUILDING. SUPPLY AND WASTE PIPING SHALL BE REMOVED TO THE

EXTERIOR. ALL PLUMBING FIXTURES AND EQUIPMENT AND PIPING

(INCLUDING IN WALLS, ABOVE CEILING AND BELOW SLAB) SHALL BE

REMOVED FROM THE BUILDING AND LEGALLY DISPOSED OF. NOT ALL

PIPING LOCATIONS MAY BE SHOWN WITH HATCHING. DEMOLISH ALL

PIPING IN BUILDING.

SEE DRAWING P-001 FOR PROJECT PLUMBING DEMOLITION NOTES AND

ADDITIONAL GENERAL DEMOLITION NOTES.

DEMOLISHED PIPING, FIXTURES AND APPURTENANCES ARE

REPRESENTED BY HATCHED DESIGNATION AND/OR KEYED NOTE.

DEMOLISH ALL HOT AND COLD WATER AND DWV PIPING THROUGHOUT

THE BUILDING. SUPPLY AND WASTE PIPING SHALL BE REMOVED TO THE

EXTERIOR. ALL PLUMBING FIXTURES AND EQUIPMENT AND PIPING

(INCLUDING IN WALLS, ABOVE CEILING AND BELOW SLAB) SHALL BE

REMOVED FROM THE BUILDING AND LEGALLY DISPOSED OF. NOT ALL

PIPING LOCATIONS MAY BE SHOWN WITH HATCHING. DEMOLISH ALL

PIPING IN BUILDING.

COORDINATE WITH GENERAL CONTRACTOR ON DEMOLITION OF WALLS,

CEILINGS AND FLOOR SLABS AS NEEDED.

3.)

1.)2.)

4.)

LEGEND

KEY NOTES

GENERAL NOTES

1/4" = 1' - 0" SCALE OF FEET

0'4' 4' 8'

MB

PROJECT PLUMBING NOTES

GENERAL NOTES: (DWG P-001 - P-301)

MB

MB

SS

V

PLBG ABBREVIATION LEGEND

CW

HW

W

SAN

T

PIPE SYMBOL LEGEND

SAN

SS

SS

V

C/A

30-240

DEG.F

0-100

PSIG

MB

05a

CLOSET

BEDROOM A

BEDROOM B

BEDROOM C

CORRIDOR

ROOM

LIVING

PORCH

SCREENED

KITCHEN

BATHROOM

ROOM

POWDER

03a

LAUNDRY

PORT

CAR

04a

CLOSET

1/4"=1'-0"

PLUMBING PLAN - BLDG. 1191

P-101

SEE DRAWING P-001 FOR PROJECT PLUMBING NOTES.

COLD AND HOT WATER PIPING AND VENT PIPING ARE LOCATED ABOVE

CEILING AND SANITARY PIPING IS LOCATED BELOW SLAB ON GRADE,

EXCEPT WHERE NOTED OTHERWISE.

SEE ARCHITECTURAL DRAWINGS FOR ELEVATIONS AND TOILET ROOM

FIXTURE HEIGHTS.

COORDINATE WITH GENERAL CONTRACTOR ON WALL FURR-OUT

LOCATIONS FOR HOSE BIBB DROPS.

GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ASSIGNMENT OF

ALL WALL/FLOOR/CEILING CUTTING AND PATCHING REQUIRED FOR THIS

TRADE WORK. FINAL FINISH ASSIGNED BY GENERAL CONTRACTOR.

2.)

1.)

3.)

4.)

5.)

NEW WATER SERVICE. WATER SERVICE WILL SERVE BOTH DOMESTIC COLD

WATER AND FIRE PROTECTION (SPRINKLER). INSTALL NEW RPZ BACKFLOW

PREVENTER (SIMILAR TO WATTS 009-LF WITH STRAINER) INSIDE BUILDING.

TAKE THE DRAIN FROM THE RPZ TO THE OUTSIDE.

ROUTE NEW 2" SANITARY FROM WASHER SERVICE BOX OUTSIDE AND

CONNECT TO NEW 4" SANITARY MAIN. INSTALL NEW VENT PIPING AND VENT

THRU ROOF FOR WASHER SERVICE BOX. COORDINATE WITH GENERAL

CONTRACTOR FOR LOCATION AND ROOF WORK.

INSTALL NEW WATER SHUT-OFF VALVE WITHIN 5 FOOT OF BUILDING.

COORDINATE LOCATION WITH MECHANICAL CONTRACTOR AND NEW HVAC

EQUIPMENT.

ARCHITECTURAL PROVIDED LAVATORY. INSTALL THERMOSTATIC MIXING

VALVE UNDER LAVATORY. SEE PLUMBING EQUIPMENT/FITTINGS SCHEDULE

ON P-301 FOR ADDITIONAL INFORMATION.

INSTALL NEW VENT THRU ROOF IN THE LOCATION OF THE OLD VENT THRU

ROOF. ROUTE AND CONNECT NEW VENT PIPING TO NEW VENT THRU ROOF.

COORDINATE INSTALLATION OF VENT THRU ROOF WITH GENERAL

CONTRACTOR AND THE ROOF REPLACEMENT.

1-1/2" VENT PIPING AND 1/2" HOT AND COLD WATER PIPING BELOW FLOOR.

WATER SERVICE TO BE ROUTED OVERHEAD TO CARPORT CLOSET. INSTALL

HOSE BIBB WITH SHUT-OFF VALVE. FIRE PROTECTION (SPRINKLER) WILL

SEPARATE IN CLOSET. SEE FIRE PROTECTION DRAWINGS FOR CONTINUATION.

WASHER SERVICE BOX (WSB) TO BE SURFACE MOUNTED.

LEGEND

KEY NOTES

GENERAL NOTES

1/4" = 1' - 0" SCALE OF FEET

0'4' 4' 8'

MB

SEE DRAWING P-001 FOR PROJECT PLUMBING NOTES.

SEE ARCHITECTURAL DRAWINGS FOR ELEVATIONS AND TOILET ROOM

FIXTURE HEIGHTS.

2.)

1.)

INSTALL NEW VENT THRU ROOF IN THE LOCATION OF THE OLD VENT THRU

ROOF. ROUTE AND CONNECT NEW VENT PIPING TO NEW VENT THRU ROOF.

COORDINATE INSTALLATION OF VENT THRU ROOF WITH GENERAL

CONTRACTOR AND THE ROOF REPLACEMENT.

LEGEND

KEY NOTES

GENERAL NOTES

MB

AND 80 STEEL PIPING

HORIZONTAL SCHEDULE 40

HORIZONTAL SCHEDULE 40

AND 80 PVC OR ABS PIPING

3/8"1/2" 5'

2-1/2"

1-1/2"

1-1/4"

5/8"

3/4"

7'

3"

2"

10'

8'

8'

1"

7'

6'

5'

5'

3/8"

1/2"

1/2"

3/8"

3/8"

3/8"

3/8"

3/8"

1/2"-2" 4'

2-1/2"-3"

6"-8"

4"

4'

4'

4'

PIPE

SIZE

HANGER

SPACING

SUPPORT

SPACING

NOTE: ALL PIPING 1" AND LARGER SHALL BE

SUPPORTED AT EACH FLOOR PENETRATION

ROD DIAMETER

HORIZONTAL COPPER

PIPING (ALL TYPES)

12'

15'

10'

ALL TYPES AND SIZES

VERTICAL PIPING

3/8"

PIPE

SIZE SPACING

HANGER

4'

4" - 14"

1" - 1-1/2"

2" - 2-1/2"

1/2"-3/4"

3/8"

3"

SIZE

PIPE

1/4"

HANGER

14"

6"-8"

10"-12"

4"-5"

12'

12'

12'

12'

3"

2-1/2"

2"

1-1/2"

1-1/4"

12'

11'

10'

9'

8'4'

8'

6'

SIZE

PIPE

SPACING

HANGER PLATE LUGS SHALL BE MSS TYPE 57.

ALL RIGID RODS HANGERS SHALL HAVE A MEANS

FOR VERTICAL ADJUSTMENT AFTER ERECTION.

HANGER INSPECTIONS SHALL BE PERFORMED IN

ACCORDANCE WITH MSS-SP89 (SECTION 7.7) AND

ASME B31.1 (APPENDIX V).

WHERE INDICATED AS ACCEPTABLE, GROOVED PIPING

SYSTEM HANGERS AND SUPPORTS SHALL BE

DESIGNED AND LAYED OUT BY THE GROOVED PIPE

SYSTEM MANUFACTURER. DRAWINGS SHALL BE

SUBMITTED TO THE ENGINEER PRIOR TO

INSTALLATION.

CUT OFF EXCESS THREADED ROD AFTER HANGER

ADJUSTMENTS HAVE BEEN MADE.

PIPE HANGERS AND SUPPORTS SHALL NOT BE

ATTACHED TO UPPER FLOOR OR ROOF, METAL

DECKING.

SEE SEPARATE ROOF SUPPORT DETAIL FOR ROOF

SUPPORT REQUIREMENTS. SPACING OF ROOF PIPE

SUPPORTS VARY FROM THOSE INDICATED HEREIN.

PIPE HANGER AND SUPPORT NOTES

PIPE HANGERS , SUPPORTS AND COMPONENTS

SHALL BE MSS SP-58, FACTORY-FABRICATED

COMPONENTS.

POWDER-ACTUATED DRIVE-PIN FASTENERS SHALL

HAVE PULL-OUT AND SHEAR CAPACITIES

APPROPRIATE FOR THE SUPPORTED LOADS AND

BUILDING MATERIALS WHERE USED.

MECHANICAL-ANCHOR FASTENERS SHALL BE

INSERT-TYPE WITH PULL-OUT AND SHEAR

CAPACITIES APPROPRIATE FOR THE SUPPORTED

LOADS AND BUILDING MATERIALS WHERE USED.

STRUCTURAL STEEL CROSS MEMBERS, SUPPORTS

AND BRACING SHALL BE ASTM A36/A 36M, STEEL

PLATES, SHAPES, AND BARS. STEEL MEMBERS SHALL

BE PAINTED OR GALVANIZED.

CHANNEL SUPPORT SYSTEMS SHALL BE MFMA-2,

FACTORY-FABRICATED COMPONENTS FOR FIELD

ASSEMBLY AS MANUFACTURED BY GRINNELL, B-LINE

OR EQUAL.

TOP BEAM C-CLAMPS SHALL BE MSS TYPE 19.

SIDE BEAM OR CHANNEL CLAMPS SHALL BE MSS

TYPE 20.

CENTER-BEAM CLAMPS SHALL BE MSS TYPE 21.

C-CLAMPS SHALL BE MSS-23

WELDED STEEL BRACKETS SHALL BE MSS TYPE 31

FOR UP TO 750 LB LOADS, MSS TYPE 32 FOR UP

TO 1500 LBS AND MSS TYPE 33 FOR LOADS UP

TO 3000 LBS.

SIDE-BEAM BRACKETS SHALL BE MSS TYPE 34.

3/8"

1/2"-5/8"

3/4"

1/2"

ROD DIAMETER

HANGER

10.)

11.)

9.)

8.)

7.)

1/2"

1"

3/4"

7/8"

5/8"

1/2"

3/8"

3/8"

3/8"

6.)

5.)

4.)

ROD DIAMETER

HANGER

3.)

2.)

1.)

16.)

15.)

14.)

13.)

12.)

PIPE HANGERS AND PIPE CLAMP DETAILS AND NOTES (SEE SECTION 15060)

GALVANIZED STEEL RODS

THREADED AT EACH END

ANCHORED TO STRUCTURE

ABOVE. ALL-THREAD ROD

MAY BE USED FOR RODS 24"

AND SHORTER.

GALVANIZED STEEL CLEVIS

HANGER. GRINNELL FIG. 260

OR EQUAL.

INSULATED STEEL OR COPPER

PIPE.

24" LONG 14 GAGE 180°

GALV. STEEL PROTECTION

SADDLE

TREATED WOOD BLOCK

GALVANIZED STEEL RISER CLAMP.

GRINNELL FIG. 261 OR EQUAL.

FOUR (4) STEEL SHEAR LUGS

WELDED TO SIDE OF PIPE. LUGS

TO BE 3"L X 1.5" X .25" FOR

PIPING 6" AND SMALLER. USE 4"H

X 2" X .375" FOR PIPING 8"-14"

STEEL PIPE.

INSULATE CLAMP ON COLD PIPING

TO REDUCE CONDENSATION.

GALVANIZED STEEL RODS

THREADED AT EACH END

ANCHORED TO STRUCTURE

ABOVE. ALL-THREAD ROD

MAY BE USED FOR RODS

24" AND SHORTER.

GALVANIZED STEEL CLEVIS

HANGER. GRINNELL FIG. 260

OR EQUAL.

INSULATED COPPER PIPE.

18" LONG 16 GAGE 180°

GALV. STEEL PROTECTION

SADDLE

GALVANIZED STEEL RODS

THREADED AT EACH END

ANCHORED TO STRUCTURE

ABOVE. ALL-THREAD ROD

MAY BE USED FOR RODS

24" AND SHORTER.

GALVANIZED STEEL CLEVIS

HANGER. GRINNELL FIG. 65

OR EQUAL.

INSULATED COPPER PIPE

12" LONG 18 GAGE 180°

GALV. STEEL PROTECTION

SADDLE

INSULATED PIPE - NOMINAL PIPE SIZE THRU 2"

INSULATED PIPE - NOMINAL PIPE SIZE THRU 1-1/2"

GALVANIZED STEEL ALL-THREAD

ROD ANCHORED TO STRUCTURE

ABOVE. ALL-THREAD ROD MAY

BE USED FOR RODS 24" AND

SHORTER.

PLASTIC COATED PLATED STEEL

PIPE RING HANGER. GRINNELL

FIG. CT-99C OR EQUAL.

INSULATED COPPER PIPE.

12" LONG 18 GAGE 180° GALV.

STEEL PROTECTION SADDLE

NOMINAL PIPE SIZE - 3/4" THRU 3" NOMINAL PIPE SIZE - 4" THRU 14"

INSULATED PIPE - NOMINAL PIPE SIZE 6" THRU 8"

GALVANIZED STEEL RISER CLAMP.

GRINNELL FIG. 261 OR EQUAL.

STEEL OR PVC PIPE.

INSULATE CLAMP ON COLD

PIPING TO REDUCE

CONDENSATION.

INSULATED PIPE - NOMINAL PIPE SIZE 1" THRU 4" INSULATED PIPE - NOMINAL PIPE SIZE 8" THRU 12"

GALVANIZED STEEL ALL-THREAD

ROD ANCHORED TO STRUCTURE

ABOVE. ALL-THREAD ROD MAY

BE USED FOR RODS 24" AND

SHORTER.

PLATED STEEL PIPE RING

HANGER. GRINNELL FIG. 69 OR

EQUAL.

INSULATED COPPER PIPE

12" LONG 18 GAGE 180° GALV.

STEEL PROTECTION SADDLE

PLASTIC COATED COPPER FINISHED

RISER CLAMP. GRINNELL FIG.

CT-121C OR EQUAL.

COPPER PIPE.

INSULATE CLAMP ON COLD PIPING

TO REDUCE CONDENSATION.

NOMINAL PIPE SIZE - .75" THRU 4"

GALVANIZED U-BOLT PIPE

CLAMP. GRINNELL FIG. 137

OR EQUAL.

UNINSULATED STEEL OR PVC

PIPE.

12 GAGE MOUNTING

CHANNEL. GRINNELL

POWERSTRUT OR EQUAL.

INSULATED PIPE - PIPE O.D. 1/2" THRU 8"

SHOP FABRICATED 18 GAGE

12" LONG 170° PROTECTION

SADDLE GLUED IN PLACE

(TOP AND BOTTOM)

TWO PIECE GALVANIZED PIPE

CLAMPS. GRINNELL MODEL

PS 1200 OR EQUAL.

INSULATED STEEL OR

COPPER PIPE.

12 GAGE MOUNTING

CHANNEL. GRINNELL

POWERSTRUT OR EQUAL.

NOMINAL PIPE SIZE .375" THRU 4"

TWO PIECE GALVANIZED PIPE

CLAMPS. GRINNELL MODEL PS

1200 OR EQUAL.

UNINSULATED STEEL OR PVC

PIPE.

12 GAGE MOUNTING CHANNEL.

GRINNELL POWERSTRUT OR

EQUAL.

NOMINAL PIPE SIZE .375" THRU 3"

TWO PIECE GALVANIZED

PIPE CLAMP WITH RUBBER

CUSHION. GRINNELL

MODEL PS 1400 OR

EQUAL.

UNINSULATED COPPER

PIPE.

12 GAGE MOUNTING

CHANNEL. GRINNELL

POWERSTRUT OR EQUAL.

NOMINAL PIPE SIZE 4" THRU 14"

GALVANIZED STEEL RODS

THREADED AT EACH END

ANCHORED TO STRUCTURE

ABOVE. ALL-THREAD ROD

MAY BE USED FOR RODS

24" AND SHORTER.

GALVANIZED STEEL CLEVIS

HANGER. GRINNELL FIG. 260

OR EQUAL.

UNINSULATED STEEL OR PVC

PIPE.

GALVANIZED STEEL ALL-THREAD

ROD ANCHORED TO STRUCTURE

ABOVE. ALL-THREAD ROD MAY

BE USED FOR RODS 24" AND

SHORTER.

PLASTIC COATED PLATED STEEL

PIPE RING HANGER. GRINNELL

FIG. CT-99C OR EQUAL.

UNINSULATED COPPER PIPE.

NOMINAL PIPE SIZE .375" THRU 3" NOMINAL PIPE SIZE 2.5" THRU 4"

GALVANIZED STEEL ALL-THREAD

ROD ANCHORED TO STRUCTURE

ABOVE. ALL-THREAD ROD MAY

BE USED FOR RODS 24" AND

SHORTER.

PLATED STEEL PIPE RING

HANGER. GRINNELL FIG. 69 OR

EQUAL.

UNINSULATED STEEL OR PVC

PIPE.

NOMINAL PIPE SIZE .375" THRU 2"

GALVANIZED STEEL RODS

THREADED AT EACH END

ANCHORED TO STRUCTURE

ABOVE. ALL-THREAD ROD

MAY BE USED FOR RODS

24" AND SHORTER.

GALVANIZED STEEL CLEVIS

HANGER. GRINNELL FIG. 65

OR EQUAL.

UNINSULATED STEEL OR

PVC PIPE.

NOMINAL PIPE SIZE 5" THRU 12"

NOTE: PIPE INSULATION TO BE CONTINUOUS THRU

PIPE HANGERS/BRACKETS.

17.)

18.)

P-201

.5" HIGH LETTERS (MINIMUM)

8" OR LONGER SNAP-ON OR WRAP-AROUND

POLYESTER LABELS WITH ADHESIVE STRIP(S).

FLOW DIRECTION ARROW

DOMESTIC HOT WATER

PLUMBING PIPING LABELING DETAILS

BACKGROUND

COLOR

LABEL TEXT AND COLOR LEGEND

1.25" O.D. AND SMALLER PIPING. (O.D. INCLUDES INSULATION WHERE REQUIRED)

BLACK

BLACK

WHITE

WHITE

WHITE

WHITE

BLACK

BLACK

BLACK

WHITE

ACID VENT

ACID WASTE

CITY WATER

COMPRESSED AIR

DEIONIZED WATER

DOMESTIC COLD WATER

DOMESTIC HOT WATER*

DOMESTIC HOT WATER

RETURN

NATURAL OR LP GAS

SANITARY DRAIN

PIPE SYSTEM

DESCRIPTION

LETTER

COLOR

DOMESTIC HOT WATER

RED

GREEN

YELLOW

WHITE

BLACK

BLUE

GREEN

WHITE

WHITE

BLACK

BLACK

WHITE

WHITE

WHITE

YELLOW

YELLOW

GREEN

BLUE

GREEN

GREEN

YELLOW

YELLOW

YELLOW

GREEN

SPRINKLER-FIRE

STORM

MEDICAL AIR

MEDICAL VACUUM

NITROGEN

NITROUS OXIDE

OXYGEN

NOT TO SCALE

PIPE SYSTEM

DESCRIPTION

BACKGROUND

COLOR

LETTER

COLOR

2" TO 6" O.D. PIPING AND ABOVE. (O.D. INCLUDES INSULATION WHERE REQUIRED)

1.5" O.D. PIPING. (O.D. INCLUDES INSULATION WHERE REQUIRED)

DOMESTIC HOT WATERDOMESTIC HOT WATER

DOMESTIC HOT WATERDOMESTIC HOT WATER

1.25" HIGH LETTERS (MINIMUM)

12" LONGER SNAP-ON OR WRAP-AROUND

POLYESTER LABELS WITH ADHESIVE STRIP(S).

FLOW DIRECTION ARROW

.75" HIGH LETTERS (MINIMUM)

8" OR LONGER SNAP-ON OR WRAP-AROUND

POLYESTER LABELS WITH ADHESIVE STRIP(S).

FLOW…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .