These are construction design drawings for the rehabilitation of three residential units (119, 120, and 124) at Pine Island Community in Everglades National Park, located in Miami-Dade County, Florida. The project, dated November 21, 2022, encompasses comprehensive architectural, structural, mechanical, plumbing, electrical, and fire protection work prepared by the National Park Service Denver Service Center.
The scope of work includes demolition of existing roofing, interior finishes, mechanical and electrical systems, and plumbing fixtures across all three units, followed by installation of new systems and finishes. Key construction elements include: new standing seam metal roofing with rafter overbuild, replacement of water-damaged wood roof decking, new terrazzo flooring with concrete slab infill, interior wall and ceiling finishes with drywall and paint, new kitchen and bathroom fixtures, new HVAC system (2-ton heat pump with air handling unit), new plumbing with domestic water service and vent systems, new electrical distribution with updated lighting and outlets, and fire sprinkler system installation. The project requires coordination among multiple trades including general, mechanical, plumbing, electrical, and fire protection contractors. Construction documents specify compliance with 2015 International Building Code, 2015 International Plumbing Code, 2018 International Energy Conservation Code, and applicable NFPA standards. The drawings indicate standard residential occupancy (R-3) with ADA accessibility requirements where applicable.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
COVER SHEET G001
NORTH
MONROE CO.
CARD SO
UND RO
ADENVIRONMENTAL
KEY WEST
TO 1
CENTER
FLORIDA
BAY
BAY
FLAMINGO
V.C.
SABLE
CAPE
WHITEWATER
OCEAN
V.C.
SOUND
BARNES
MCLAUGHLIN
KEY
MEXICO
GULF OF
OCHOPEE
NAPLES
TO
EVERGLADES
COAST
GULF
V.C.
CITY
FORT MYERS
BIG CYPRESS29
TO
RESERVATION
FL
O
R
ID
A' S
TU
R
N
PI
KE
MONROE COUNTY
HIDDEN LAKE
CENTER
BEARD
DANIEL
LOOP
D
AD
E C
O U
N
TY
M O
N R
O E
C O
U N
TY
ROAD
TAMIAMI
PALM
ROYAL
CENTER
HQ.
RESEARCH
CITY
MAIN
V.C.
FLORIDA
CITY
LEISURE
HOMESTEAD
CHEKIKA
VALLEY
SHARK
MUCCOSUKEE
PRESERVE
COLLIER COUNTY
TAMIAMI TRAIL
NATIONAL
INDIAN
ATLANTIC
LARGO
KEY
NATIONAL
DADE CO.
PARK
BISCAYNE
DRIVECANAL
FORT LAUDERDALE
MIAMI
TO
UNESCO
EVERGLADES NATIONAL PARK
WORLD HERITAGE SITE
PARK OFFICIAL FOR LIMITATIONS.
FEDERAL GOVERNMENT. CHECK WITH LOCAL
PARK HAVE BEEN ACQUIRED BY THE
BOUNDARY OF THE EVERGLADES NATIONAL
NOT ALL LANDS INSIDE THE AUTHORIZED
NOTE
SWAMP OR SLOUGH
PUBLIC AIRPORTS
OBSERVATION TOWER
INFORMATION CENTER
RANGER STATION
PARK HEADQUARTERS
VISITOR CENTER
HQ.
V.C.
CREEK
LEGEND
PARK BOUNDARY
COUNTY LINE
BASIC DATA: BOUNDARY MAPS 160/20,013B 9/89; 160/20,012 3/85; PARK MINI FOLDER 1992; REVISED & REDRAWN 5/93. UPDATED 11/98. SGS.
MEXICO
OF
GULF
LE
E
C O
ATLANTIC
FLORIDA BAY
EVERGLADES
PARK
NATIONAL
KEY LARGO
OCEAN
NORTH MIAMI BEACH
FORT LAUDERDALE
H
EN
D R
Y C
O
KENDALL
PALM BEACH CO.
DADE CO.
BROWARD CO.
FLORIDA CITY
HOMESTEAD
PRINSTON
C O
LL
IE
R C
O
MONROE CO.
PRESERVE
NATIONAL
BIG CYPRESS
MIAMI
NATIONAL
BISCAYNE
PARK
HOLLYWOOD
SCALE IN MILES
10 0 10 20SOUTHERN
FLORIDA
176672
SCALE IN MILES
SCALE IN KILOMETERS
5 0
15105
5 10 LOCATION WITHIN PARK
NAME OF PARK
TITLE OF SHEET
EVERGLADES NATIONAL PARK
PINE ISLAND COMMUNITY
STATEREGION COUNTY
SOUTHEAST FLORIDAMIAMI-DADE
PMIS / PKG. NO.
SHEET
DRAWING NO.
OF 34
DATE:
TECH. REVIEW:
DRAWN:
DESIGNED:REVISIONS SUB SHEET NO.
NATIONAL PARK SERVICE
DENVER SERVICE CENTER
DEPARTMENT OF THE INTERIOR
UNITED STATES
KS/EW
EW / CH
11/21/2022
KS / CH 305612
11/21/2022
5' -3
8'-1"
'-7
2'-6"
1' -1
33'-0"
1' -5
6'
-5
8' -7
AREA OF FINISH DEMOLITION
(CEILING AND/OR FLOORS)
EXISTING CONSTRUCTION
TO REMAIN
EXISTING CONSTRUCTION
TO BE DEMOLISHED
DOOR TO BE DEMOLISHED
FRAME TO REMAIN
DOOR AND FRAME TO
REMAIN
D101 SCALE 14" = 1'
D101 SCALE 14" = 1'
A INTERIOR DOORS: DEMOLISH INTERIOR DOORS AND HARDWARE. INTERIOR DOOR FRAMES SHALL REMAIN.
B EXTERIOR DOORS: DEMOLISH DOORS AND HARDWARE; GENERAL CONTRACTOR TO EVAULATE CONDITION OF
FRAME AND ADVISE OWNER
C INTERIOR FINISHES: PLASTER AND PLASTERBOARD WALL AND CEILING FINISHES SHALL BE CUT, TRENCHED, DEMOLISHED AS REQUIRED TO INSTALL NEW WORK. MINIMIZE INTERIOR FINISH DEMOLITION, UTILIZE DEMOLISHED CEILING AREA IN CORRIDOR FOR ACCESS TO ATTIC SPACE. FINISH DEMOLITION SHALL BE CARRIED OUT BY MAKING CLEAN STRAIGHT CUTS IN FINISHES AND DEMOLISHING FINISHES WITHIN CUT AREAS. WALL AND CEILING FRAMING SHALL BE PRESERVED UN-DAMAGED. ALL DAMAGE RESULTING FROM DEMO WORK SHALL BE PATCHED AND
REPAIRED TO MATCH ADJACENT WALL FINISH AND TEXTURE.
D FLOOR FINISHES: TERRAZZO FLOOR AND CONCRETE SLAB SUBSTRATE SHALL BE CUT, TRENCED, DEMOLISHED AS REQUIRED TO INSTALL NEW WORK. MINIMIZE FLOOR SLAB DEMOLITION. LOCATE UNDERSLAB PIPING AND OTHER UTILITIES BY NON-DESTRUCTIVE MEANS PRIOR TO BEGINNING DEMOLITION. SAWCUT TERRAZZO FINISH AND
CONCRETE SLAB IN CLEAN STRAIGHT AND ORTHOGONAL LINES.
E INTERIOR WOOD TRIM: BASE TRIM AND DOOR TRIM SHALL BE DEMOLISHED ONLY WHERE REQUIRED TO CARRY OUT NEW WORK. SALVAGE TRIM FOR REUSE. PROVIDE NEW TRIM WHERE REUSE OF SALVAGED TRIM IS NOT
POSSIBLE
F WINDOWS: EXTERIOR WINDOWS ARE NOT IN CONTRACT. PROTECT WINDOWS FROM DAMAGE DURING THE
COURSE OF THE NEW WORK
G ROOF: DEMOLISH ROOFING DOWN TO THE ROOF DECK. INSPECT ROOF DECK FOR WATER DAMAGE AND SUITABILITY FOR INSTALLATION OF NEW ROOF. SURVEY FLAT ROOF AREAS WITH TONGUE AND GROOVE WOOD PLANK DECK FOR WATER DAMAGE BEYOND THE KNOWN DAMAGED AREAS INDICATED ON DRAWINGS. ADVISE CONTRACT OFFICER OF FINDINGS PRIOR TO CARRYING OUT ADDITIONAL DEMOLITION OR INSTALLING NEW WORK.
ANY DETERIORATED SUBSTRATE (PLYWOOD SHEATHING, BUILDING WRAP, ECT) IS TO BE REMOVED.
H WINDOWS SHADES/BLINDS: DEMOLISH LOUVRE BLINDS, VALENCES, HANGERS AND ALL BRACKETS AND ANCHORS AT EACH WINDOW IN EACH UNIT. PATCH AND REPAIR ANY DAMAGE MADE BY REMOVAL OF BRACKETS, ANCHORS, OR OTHER.
D1 DEMOLISH ALUMINUM-FRAMED SCREENWALL SYSTEM
D2 DEMOLISH CONCRETE CONDENSING UNIT PAD
D3 DEMOLISH ROOF OVERHANG SOFFITS AND VENTS
D4 DEMOLISH CLOSET SLIDING DOORS AND TRACKS
D5 DEMOLISH KITCHEN CABINETS
D6 DEMOLISH KITCHEN APPLIANCES
D7 DEMOLISH FLOOR TILE (UNIT 119 ONLY)
D8 DEMOLISH SINK VANITIES, WALL CABINETS, MIRRORS, TOWEL AND TOILET PAPER HOLDERS, SOAP TRAYS, ETC AND
ALL FASTENERS OR ANCHORS
D9 DEMOLISH WALL TILE AND SUBSTRATE AND/OR BACKERBOARD.
D10 EXISTING LIGHT SHELF TO REMAIN - REFER TO ELECTRICAL
D11 DEMOLISH EXISTING WATER-DAMAGED WOOD PLANK ROOF DECK, HATCHED AREA INDICATES APPROXIMATE
EXTENTS OF KNOWN DAMAGE. ALL DETERIORATED OR WATER-DAMAGED DECK SHALL BE REMOVED, ADVISE
CONTRACT OFFICER IF DAMAGE AREA IS FOUND TO EXTEND BEYOND THE INDICATED EXTENTS.
D12 DEMOLISH WOOD SHELVING, BRACKETS, SUPPORTS, HOOKS, HANGERS, ANCHORS, ETC. INSIDE OF CLOSET. PATCH
HOLES.
D13 SAWCUT AND DEMOLISH CONCRETE FLOOR SLAB FOR EXTENTS REQUIRED TO DEMOLISH EXISTING UNDERSLAB PIPING AND INSTALL NEW WORK. HATCHED AREA INDICATES APPROXIMATE EXTENTS. REFER TO NEW WORK
DRAWINGS FOR PATCH AND REPAIR SCOPE.
D14 DEMOLISH PLASTER AND/OR GYPSUM BOARD WALL FINISHES BOTH SIDES OF WALL AND AS REQUIRED TO
DEMOLISH EXISTING ELECTRICAL AND PLUMBING, AND INSTALL NEW WORK.
D15 DEMOLISH EXISTING WALL FROM 42" AFF TO SLOPED CEILING
D16 DEMOLISH WALLCOVERING FROM FULL EXTENTS OF WALL
D17 DEMOLISH CLOSET IN CORRIDOR AND BEDROOM A INCLUDING WOOD SHELVING, DOORS, AND OTHER
COMPONENTS.
D18 DEMOLISH SURFACE-MOUNTED HOUSE NUMBERS. EXACT LOCATION MAY VARY AT EACH UNIT.
D19 DEMOLISH HOSE BRACKET
D20 DEMOLISH ANTENNA AND ASSOCIATED BRACKETS AND WIRING. PATCH AND REPAIR EXISTING FINISHES AS
REQUIRED. REFER TO ELECTRICAL FOR SCOPE OF SATELLITE DISH
D21 DEMOLISH CORRUGATED METAL PANEL HURRICANE SHUTTERS AND SUPPORTS AT TOP AND BOTTOM OF WALL.
PATCH AND REPAIR SUBSTRATES.
D22 DEMOLISH PLASTER AND/OR DRYWALL CEILING FINISH FOR EXTENTS INDICATED.
D23 REMOVE WALL MOUNTED FIRE EXTINGUISHER
349*��)*241.8-�1&:3)7>�)4478 &3)�<&11�&9�:3.9� 11��431>
1/4" = 1' - 0" SCALE OF FEET
0'4' 4' 8'
1*G*3)
SCREENED
PORCH
D
D104 D104
D
4 G*3*7&1�349*8
0*>�349*8
24'-2"
2' -9
'-6
54'-0"
4' -6
16'-10"
2' -9
5'
-4
2'-10"
'-4
3'-0"
11'-8"
'-3
AREA OF FINISH DEMOLITION
(CEILING AND/OR FLOORS)
EXISTING CONSTRUCTION
TO REMAIN
EXISTING CONSTRUCTION
TO BE DEMOLISHED
DOOR TO BE DEMOLISHED
FRAME TO REMAIN
DOOR AND FRAME TO
REMAIN
D102 SCALE 14" = 1'
A INTERIOR DOORS: DEMO INTERIOR DOORS AND HARDWARE. INTERIOR DOOR FRAMES SHALL REMAIN.
B EXTERIOR DOORS: DEMOLISH EXTERIOR DOOR AND HARDWARE. GENERAL CONTRACTOR TO EVALUATE CONDITION
OF FRAME AND ADVISE CONTRACT OFFICER. REFER TO KEYNOTES FOR SCOPE OF SCREEN DOORS.
C INTERIOR FINISHES SHALL BE CUT, TRENCHED, DEMOLISHED AS REQUIRED TO INSTALL NEW WORK. MINIMIZE
INTERIOR FINISH DEMO, UTILIZE DEMOLISHED CEILING AREA IN CORRIDOR FOR ACCESS TO ATTIC SPACE. FINISH DEMO SHALL BE CARRIED OUT BY MAKING CLEAN STRAIGHT CUTS IN FINISHES AND DEMOLISHING FINISHES WITHIN CUT AREAS. WALL AND CEILING FRAMING SHALL BE PRESERVED UN-DAMAGED. ALL DAMAGE RESULTING FROM DEMO WORK SHALL BE PATCHED AND REPAIRED TO MATCH ADJACENT WALL FINISH AND TEXTURE.
D FLOOR FINISHES: TERRAZZO FLOOR AND CONCRETE SLAB SUBSTRATE SHALL BE CUT, TRENCED, DEMOLISHED AS REQUIRED TO INSTALL NEW WORK. MINIMIZE FLOOR SLAB DEMO. LOCATE UNDERSLAB PIPING AND OTHER UTILITIES BY NON-DESTRUCTIVE MEANS PRIOR TO BEGINNING DEMO. SAWCUT TERRAZZO FINISH AND CONCRETE
SLAB IN CLEAN STRAIGHT AND ORTHOGONAL LINES.
E INTERIOR WOOD TRIM: BASE TRIM AND DOOR TRIM SHALL BE DEMOLISHED ONLY WHERE REQUIRED TO CARRY OUT NEW WORK. SALVAGE TRIM FOR REUSE. PROVIDE NEW TRIM WHERE REUSE OF SALVAGED TRIM IS NOT
POSSIBLE (PROFILE TO MATCH EXISTING TRIM)
F WINDOWS: EXTERIOR WINDOWS NIC. PROTECT WINDOWS AND HURRICANE SHUTTERS FROM DAMAGE DURING
THE COURSE OF CONSTRUCTION.
G EXTERIOR WOOD SIDING: DEMO EXISTING WOOD SIDING AND FASTENERS IN ENTIRETY. REMOVE BUILDING PAPER OR BUILDING WRAP IF PRESENT. ADVISE CONTRACT OFFICER OF DETERIORATED SUBSTRATE AND AWAIT DIRECTION
ON REPLACEMENT MATERIALS AND METHODS.
H WINDOWS SHADES/BLINDS: DEMO LOUVRE BLINDS, VALENCES, HANGERS AND ALL BRACKETS AND ANCHORS AT EACH WINDOW AND SLIDING DOOR IN EACH UNIT. PATCH AND REPAIR ANY DAMAGE MADE BY REMOVAL OF
BRACKETS, ANCHORS, OR OTHER COMPONENTS TO MATCH ADJACENT EXISTING SURFACES.
D1 DEMOLISH ALUMINUM-FRAMED SCREENWALL SYSTEM
D2 DEMOLISH CONCRETE CONDENSING UNIT PAD
D3 DEMOLISH ROOF OVERHANG SOFFITS AND VENTS
D4 DEMOLISH CLOSET SLIDING DOORS AND TRACKS
D5 DEMOLISH KITCHEN CABINETS
D6 DEMOLISH KITCHEN APPLIANCES
D7 DEMOLISH FLOOR TILE (UNIT 119 ONLY)
D8 DEMOLISH SINK VANITIES, WALL CABINETS, MIRRORS, TOWEL AND TOILET PAPER HOLDERS, SOAP TRAYS, ETC AND
ALL FASTENERS OR ANCHORS
D9 DEMOLISH WALL TILE AND SUBSTRATE AND/OR BACKERBOARD.
D10 EXISTING LIGHT SHELF TO REMAIN - REFER TO ELECTRICAL
D11 DEMOLISH EXISTING WATER-DAMAGED WOOD PLANK ROOF DECK, HATCHED AREA INDICATES APPROXIMATE
EXTENTS OF KNOWN DAMAGE. ALL DETERIORATED OR WATER-DAMAGED DECK SHALL BE REMOVED, ADVISE
CONTRACT OFFICER IF DAMAGE AREA IS FOUND TO EXTEND BEYOND THE INDICATED EXTENTS.
D12 DEMOLISH WOOD SHELVING, BRACKETS, SUPPORTS, HOOKS, HANGERS, ANCHORS, ETC. INSIDE OF CLOSET. PATCH
HOLES.
D13 SAWCUT AND DEMOLISH CONCRETE FLOOR SLAB FOR EXTENTS REQUIRED TO DEMOLISH EXISTING UNDERSLAB PIPING AND INSTALL NEW WORK. HATCHED AREA INDICATES APPROXIMATE EXTENTS. REFER TO NEW WORK
DRAWINGS FOR PATCH AND REPAIR SCOPE.
D14 DEMOLISH PLASTER AND/OR GYPSUM BOARD WALL FINISHES BOTH SIDES OF WALL AND AS REQUIRED TO
DEMOLISH EXISTING ELECTRICAL AND PLUMBING, AND INSTALL NEW WORK.
D15 DEMOLISH EXISTING WALL FROM 42" AFF TO SLOPED CEILING
D16 DEMOLISH WALLCOVERING FROM FULL EXTENTS OF WALL
D17 DEMOLISH CLOSET IN CORRIDOR AND BEDROOM A INCLUDING WOOD SHELVING, DOORS, AND OTHER
COMPONENTS.
D18 DEMOLISH SURFACE-MOUNTED HOUSE NUMBERS. EXACT LOCATION MAY VARY AT EACH UNIT.
D19 DEMOLISH HOSE BRACKET
D20 DEMOLISH ANTENNA AND ASSOCIATED BRACKETS AND WIRING. PATCH AND REPAIR EXISTING FINISHES AS
REQUIRED. REFER TO ELECTRICAL FOR SCOPE OF SATELLITE DISH
D21 DEMOLISH CORRUGATED METAL PANEL HURRICANE SHUTTERS AND SUPPORTS AT TOP AND BOTTOM OF WALL.
PATCH AND REPAIR SUBSTRATES.
D22 DEMOLISH PLASTER AND/OR DRYWALL CEILING FINISH FOR EXTENTS INDICATED.
0*>�349*8
G*3*7&1�349*8
1/4" = 1' - 0" SCALE OF FEET
0'4' 4' 8'
1*G*3)
'-0
'-0
'-0
22'-10" 23'-7"
82'-6"
48'-6"
'-0
36'-1"
3' -0
'-0
3' -0
3'-0"
3'-0"
8' -0
9' -0
D103 SCALE 14" = 1'
A INTERIOR DOORS: DEMO INTERIOR DOORS AND HARDWARE. INTERIOR DOOR FRAMES SHALL REMAIN.
B EXTERIOR DOORS: DEMOLISH EXTERIOR DOOR AND HARDWARE. GENERAL CONTRACTOR TO EVALUATE CONDITION
OF FRAME AND ADVISE CONTRACT OFFICER. REFER TO KEYNOTES FOR SCOPE OF SCREEN DOORS.
C INTERIOR FINISHES SHALL BE CUT, TRENCHED, DEMOLISHED AS REQUIRED TO INSTALL NEW WORK. MINIMIZE
INTERIOR FINISH DEMO, UTILIZE DEMOLISHED CEILING AREA IN CORRIDOR FOR ACCESS TO ATTIC SPACE. FINISH DEMO SHALL BE CARRIED OUT BY MAKING CLEAN STRAIGHT CUTS IN FINISHES AND DEMOLISHING FINISHES WITHIN CUT AREAS. WALL AND CEILING FRAMING SHALL BE PRESERVED UN-DAMAGED. ALL DAMAGE RESULTING FROM DEMO WORK SHALL BE PATCHED AND REPAIRED TO MATCH ADJACENT WALL FINISH AND TEXTURE.
D FLOOR FINISHES: TERRAZZO FLOOR AND CONCRETE SLAB SUBSTRATE SHALL BE CUT, TRENCED, DEMOLISHED AS REQUIRED TO INSTALL NEW WORK. MINIMIZE FLOOR SLAB DEMO. LOCATE UNDERSLAB PIPING AND OTHER UTILITIES BY NON-DESTRUCTIVE MEANS PRIOR TO BEGINNING DEMO. SAWCUT TERRAZZO FINISH AND CONCRETE
SLAB IN CLEAN STRAIGHT AND ORTHOGONAL LINES.
E INTERIOR WOOD TRIM: BASE TRIM AND DOOR TRIM SHALL BE DEMOLISHED ONLY WHERE REQUIRED TO CARRY OUT NEW WORK. SALVAGE TRIM FOR REUSE. PROVIDE NEW TRIM WHERE REUSE OF SALVAGED TRIM IS NOT
POSSIBLE (PROFILE TO MATCH EXISTING TRIM)
F WINDOWS: EXTERIOR WINDOWS NIC. PROTECT WINDOWS AND HURRICANE SHUTTERS FROM DAMAGE DURING
THE COURSE OF CONSTRUCTION.
G EXTERIOR WOOD SIDING: DEMO EXISTING WOOD SIDING AND FASTENERS IN ENTIRETY. REMOVE BUILDING PAPER OR BUILDING WRAP IF PRESENT. ADVISE CONTRACT OFFICER OF DETERIORATED SUBSTRATE AND AWAIT DIRECTION
ON REPLACEMENT MATERIALS AND METHODS.
H WINDOWS SHADES/BLINDS: DEMO LOUVRE BLINDS, VALENCES, HANGERS AND ALL BRACKETS AND ANCHORS AT EACH WINDOW AND SLIDING DOOR IN EACH UNIT. PATCH AND REPAIR ANY DAMAGE MADE BY REMOVAL OF
BRACKETS, ANCHORS, OR OTHER COMPONENTS TO MATCH ADJACENT EXISTING SURFACES.
DR01 DEMOLISH ASPHALT ROLL-ROOFING, UNDERLAYMENT, EDGE TRIMS, FASCIAS AND DRIP EDGES. DETERIORATED SUBSTRATES OR SHEATHING SHALL BE REMOVED AND REPLACED. ADVISE CONTRACT OFFICER OF DETERIORATED
MATERIALS AND AWAIT DIRECTION ON REPLACEMENT MATERIALS AND METHODS.
DR02
DEMOLISH ASPHALT ROLL ROOFING AND SUBSTRATE AT GABLE ENDS, UNIT #119 ONLY.
DR03 AT UNIT #119 DEMOLISH ASPHALT SHINGLE ROOFING FROM SLOPED ROOF AREA. DEMOLISH UNDERLAYMENT, EDGE TRIMS, FASCIAS AND DRIP EDGES. DETERIORATED SUBSTRATES OR SHEATHING SHALL BE REMOVED AND REPLACED. ADVISE CONTRACT OFFICER OF DETERIORATED MATERIALS AND AWAIT DIRECTION ON REPLACEMENT
MATERIALS AND METHODS.
DR04 AT UNITS #120 AND #124 DEMOLISH ASPHALT ROLL-ROOFING FROM LOW SLOPED ROOF AREA. DEMOLISH UNDERLAYMENT, EDGE TRIMS, FASCIAS AND DRIP EDGES. DETERIORATED SUBSTRATES OR SHEATHING SHALL BE REMOVED AND REPLACED. ADVISE CONTRACT OFFICER OF DETERIORATED MATERIALS AND AWAIT DIRECTION
ON REPLACEMENT MATERIALS AND METHODS.
DR05 REMOVE AND SALVAGE EXISTING ROOF VENTILATORS FOR RE-INSTALLATION
DR06 DEMOLISH ROOF AND STACK VENTS
SL
O
PE
SL
O
PE
G*3*7&1�349*8
1/4" = 1' - 0" SCALE OF FEET
0'4' 4' 8'
0*>�349*8
D102 SCALE 18" = 1'
D102 SCALE 18" = 1'
D102 SCALE 18" = 1'
D102 SCALE 18" = 1'
A INTERIOR DOORS: DEMO INTERIOR DOORS AND HARDWARE. INTERIOR DOOR FRAMES SHALL REMAIN.
B EXTERIOR DOORS: DEMOLISH EXTERIOR DOOR AND HARDWARE. GENERAL CONTRACTOR TO EVALUATE CONDITION
OF FRAME AND ADVISE CONTRACT OFFICER. REFER TO KEYNOTES FOR SCOPE OF SCREEN DOORS.
C INTERIOR FINISHES SHALL BE CUT, TRENCHED, DEMOLISHED AS REQUIRED TO INSTALL NEW WORK. MINIMIZE
INTERIOR FINISH DEMO, UTILIZE DEMOLISHED CEILING AREA IN CORRIDOR FOR ACCESS TO ATTIC SPACE. FINISH DEMO SHALL BE CARRIED OUT BY MAKING CLEAN STRAIGHT CUTS IN FINISHES AND DEMOLISHING FINISHES WITHIN CUT AREAS. WALL AND CEILING FRAMING SHALL BE PRESERVED UN-DAMAGED. ALL DAMAGE RESULTING FROM DEMO WORK SHALL BE PATCHED AND REPAIRED TO MATCH ADJACENT WALL FINISH AND TEXTURE.
D FLOOR FINISHES: TERRAZZO FLOOR AND CONCRETE SLAB SUBSTRATE SHALL BE CUT, TRENCED, DEMOLISHED AS REQUIRED TO INSTALL NEW WORK. MINIMIZE FLOOR SLAB DEMO. LOCATE UNDERSLAB PIPING AND OTHER UTILITIES BY NON-DESTRUCTIVE MEANS PRIOR TO BEGINNING DEMO. SAWCUT TERRAZZO FINISH AND CONCRETE
SLAB IN CLEAN STRAIGHT AND ORTHOGONAL LINES.
E INTERIOR WOOD TRIM: BASE TRIM AND DOOR TRIM SHALL BE DEMOLISHED ONLY WHERE REQUIRED TO CARRY OUT NEW WORK. SALVAGE TRIM FOR REUSE. PROVIDE NEW TRIM WHERE REUSE OF SALVAGED TRIM IS NOT
POSSIBLE (PROFILE TO MATCH EXISTING TRIM)
F WINDOWS: EXTERIOR WINDOWS NIC. PROTECT WINDOWS AND HURRICANE SHUTTERS FROM DAMAGE DURING
THE COURSE OF CONSTRUCTION.
G EXTERIOR WOOD SIDING: DEMO EXISTING WOOD SIDING AND FASTENERS IN ENTIRETY. REMOVE BUILDING PAPER OR BUILDING WRAP IF PRESENT. ADVISE CONTRACT OFFICER OF DETERIORATED SUBSTRATE AND AWAIT DIRECTION
ON REPLACEMENT MATERIALS AND METHODS.
H WINDOWS SHADES/BLINDS: DEMO LOUVRE BLINDS, VALENCES, HANGERS AND ALL BRACKETS AND ANCHORS AT EACH WINDOW AND SLIDING DOOR IN EACH UNIT. PATCH AND REPAIR ANY DAMAGE MADE BY REMOVAL OF
BRACKETS, ANCHORS, OR OTHER COMPONENTS TO MATCH ADJACENT EXISTING SURFACES.
D1 DEMOLISH ALUMINUM-FRAMED SCREENWALL SYSTEM
D2 DEMOLISH CONCRETE CONDENSING UNIT PAD
D3 DEMOLISH ROOF OVERHANG SOFFITS AND VENTS
D4 DEMOLISH CLOSET SLIDING DOORS AND TRACKS
D5 DEMOLISH KITCHEN CABINETS
D6 DEMOLISH KITCHEN APPLIANCES
D7 DEMOLISH FLOOR TILE (UNIT 119 ONLY)
D8 DEMOLISH SINK VANITIES, WALL CABINETS, MIRRORS, TOWEL AND TOILET PAPER HOLDERS, SOAP TRAYS, ETC AND
ALL FASTENERS OR ANCHORS
D9 DEMOLISH WALL TILE AND SUBSTRATE AND/OR BACKERBOARD.
D10 EXISTING LIGHT SHELF TO REMAIN - REFER TO ELECTRICAL
D11 DEMOLISH EXISTING WATER-DAMAGED WOOD PLANK ROOF DECK, HATCHED AREA INDICATES APPROXIMATE
EXTENTS OF KNOWN DAMAGE. ALL DETERIORATED OR WATER-DAMAGED DECK SHALL BE REMOVED, ADVISE
CONTRACT OFFICER IF DAMAGE AREA IS FOUND TO EXTEND BEYOND THE INDICATED EXTENTS.
D12 DEMOLISH WOOD SHELVING, BRACKETS, SUPPORTS, HOOKS, HANGERS, ANCHORS, ETC. INSIDE OF CLOSET. PATCH
HOLES.
D13 SAWCUT AND DEMOLISH CONCRETE FLOOR SLAB FOR EXTENTS REQUIRED TO DEMOLISH EXISTING UNDERSLAB PIPING AND INSTALL NEW WORK. HATCHED AREA INDICATES APPROXIMATE EXTENTS. REFER TO NEW WORK
DRAWINGS FOR PATCH AND REPAIR SCOPE.
D14 DEMOLISH PLASTER AND/OR GYPSUM BOARD WALL FINISHES BOTH SIDES OF WALL AND AS REQUIRED TO
DEMOLISH EXISTING ELECTRICAL AND PLUMBING, AND INSTALL NEW WORK.
D15 DEMOLISH EXISTING WALL FROM 42" AFF TO SLOPED CEILING
D16 DEMOLISH WALLCOVERING FROM FULL EXTENTS OF WALL
D17 DEMOLISH CLOSET IN CORRIDOR AND BEDROOM A INCLUDING WOOD SHELVING, DOORS, AND OTHER
COMPONENTS.
D18 DEMOLISH SURFACE-MOUNTED HOUSE NUMBERS. EXACT LOCATION MAY VARY AT EACH UNIT.
D19 DEMOLISH HOSE BRACKET
D20 DEMOLISH ANTENNA AND ASSOCIATED BRACKETS AND WIRING. PATCH AND REPAIR EXISTING FINISHES AS
REQUIRED. REFER TO ELECTRICAL FOR SCOPE OF SATELLITE DISH
D21 DEMOLISH CORRUGATED METAL PANEL HURRICANE SHUTTERS AND SUPPORTS AT TOP AND BOTTOM OF WALL.
PATCH AND REPAIR SUBSTRATES.
D22 DEMOLISH PLASTER AND/OR DRYWALL CEILING FINISH FOR EXTENTS INDICATED.
1/4" = 1' - 0" SCALE OF FEET
0'4' 4' 8'
0*>�349*8
G*3*7&1�349*8
OPEN
TO
BEYOND
OPEN
TO
BEYOND
A101
1 FLOOR PLAN
SLAB REPAIR AND INFILL DETAIL
A101
2 CONCRETE HVAC PAD DETAIL
A101
SCALE: B
KEY NOTES
GENERAL NOTES
SCALE: B
SCALE: A
WINDOW SHADE SCHEDULE
A PROTECT ALL EXISTING FINISHES FROM DAMAGE DURING THE COURSE OF THE WORK.
PROVIDE PROTECTIVE FLOOR COVERINGS FOR FULL EXTENT OF INTERIOR FINISH FLOORS.
PROTECT CABINETS, APPLIANCES, FIXTURES AND OTHER EXISTING-TO-REMAIN ITEMS
WITH PLASTIC OR OTHER PROTECTIVE MEANS.
B INTERIOR PAINTING SCOPE:- EXISTING PAINTED INTERIOR SURFACES SHALL BE PAINTED.
INCLUDING BUT NOT LIMITED TO WALLS, CEILINGS, TRIM, DOORS, CLOSET INTERIORS
AND CLOSET DOORS, AND EXPOSED WOOD ROOF DECK PLANKS.- PREPARE ALL
SURFACES BY REMOVING EXISTING FASTENERS, ANCHORS OR OTHER ITEMS. FILL AND
PATCH ALL HOLES AND CRACKS. SCRAPE AND REMOVE FLAKING OR UNADHERED PAINT.-
REFER TO PAINTING SPECIFICATION FOR PAINT SYSTEMSPAINT COLOR SELECTIONS:-
PNT-1: CEILINGS- PNT-2: INTERIOR WALLS- PNT-3: CLOSETS AND SHELVING INTERIORS
AND TRIM
C DIMENSIONS PROVIDED ARE APPROXIMATE. ALL DIMENSIONS SHALL BE FIELD VERIFIED
BY CONTRACTOR.
D NEW INTERIOR PARTITION ASSEMBLY SHALL BE 2X4 WOOD FRAMING WITH 1/2"
DRYWALL EACH SIDE.
1 NEW CONCRETE PAD FOR CONDENSING UNIT. COORDINATE SIZE WITH MANUFACTURER
RECOMMENDATIONS
2 NEW VENTED FIBER CEMENT SOFFIT PANELS, DASHED LINE INDICATES EXTENT OF
VENTED PANELS.
3 NEW TERRAZZO FINISH ON NEW SLAB INFILL
4 PROVIDE HURRICANE PANELING SYSTEM MATCHING EXISTING DEMOLISHED SYSTEM.
REFER TO NOTES ON A301.
5 REPLACE WOOD ROOF DECK PLANKS WITH NEW PLANKS OF SAME DIMENSION
6 DEMOLISH AND REPLACE EXISTING ICLOSET DOORS, HARDWARE AND SLIDING TRACKS
AT EACH CLOSET. REPLACE WITH BI-FOLD DOORS AND ADD SHELF AND POLE AT EACH.
7 PATCH EXISTING WALL AS REQUIRED FOR INSTALLATION OF ELECTRICAL PANEL (REFER
TO ELECTRICAL)
8 WALL MOUNTED FIRE EXTINGUISHER -- REFER TO SPECIFICATIONS
9 REFER TO HARDWARE SET 10 IN SPECIFICATION SECTION 08 71 00 FOR CLOSET
HARDWARE
10 24x24 PLYWOOD ACCESS PANEL (PTD) IN DRYWALL CEILING - COORDINATE FINAL
LOCATION WITH WORK IN ATTIC - HEADERS TO MATCH BOTTOM CORD OF ROOF TRUSS -
1x3 WOOD TRIM (PTD) WITH 1/2" FOAM TAPE ALL SIDES
11 DRYWALL CEILING FINISH (PAINTED) MATCH EXISTING CEILING HEIGHT AND TIE INTO
EXISTING BULKHEAD IN LIVING ROOM (01)
12 DRYWALL CEILING FINISH (PAINTED) MATCH EXISTING CEILING SLOPE
WS-1 ROLLER WINDOW SHADE -- REFER TO SPECIFICATIONS
Pantry
HVAC
Closet
W
D
WH
A.H.U.
SCREENED
PORCH
LIVING
ROOM
CAR
PORT
KITCHEN
BATHROOM
POWDER
ROOM
BEDROOM
A
BEDROOM
B
BEDROOM
C
04a
CLOSET
CORRIDOR
03a
LAUNDRY
01a
05a
03d
04a
04b
04c
03c
03b
01b
03a
XX-XX 1
A401
XX-XX 4
0905b
XX-XX 4
SW-1
XX-XX 6
XX-XX 6
SAND, PATCH & APPLY EPOXY
COAT OVER SLAB IN COLOR TO
MATCH EXISTING @ PORCH
RESTORE EXIST TERRAZZO FLOORING
@ ALL LOC. U.O.N. REMOVE SEALER,
FINE GRIND, ADD GROUT AS NEEDED,
POLISH 200 GRIT AND APPLY NEW
REPLACE EXIST
SLABS IN-KIND @
ALL ENTRIES (TYP)
REBUILD CLOSET WALL TO
MEET 36" MIN REQ
CLEARANCE. RELOCATE
DOORS 01b AND 03c AS REQ
36" MIN
A201
A201
A201
A201
2' -9
NEW TERRAZZO FINISH
CONCRETE SLAB INFILL
0' -4
0'-4"
3" MIN. #57 STONE
4' x4' WELDED WIRE
MESH REINFORCING
AT MID-POINT OF SLAB
3" MIN. #57 STONE
0' -6
0' -4
HATCHED AREA INDICATES APPROXIMATE EXTENTS OF
NEW TERRAZZO FLOOR FINISH. COORDINATE WITH
EXTENTS OF REQUIRED SLAB DEMOLITION AND INFILL
HATCHED AREA INDICATES APPROXIMATE EXTENTS OF NEW
CEILING FINISH. COORDINATE WITH EXTENTS OF REQUIRED
CEILING DEMO.
A101
01a
05a
03d
04a
04b
04c
03c
03b
03a
SCALE: BA101 A101A101
A PROTECT ALL EXISTING FINISHES FROM DAMAGE DURING THE COURSE OF THE
WORK. PROVIDE PROTECTIVE FLOOR COVERINGS FOR FULL EXTENT OF
INTERIOR FINISH FLOORS. PROTECT CABINETS, APPLIANCES, FIXTURES AND
OTHER EXISTING-TO-REMAIN ITEMS WITH PLASTIC OR OTHER PROTECTIVE
MEANS.
B INTERIOR PAINTING SCOPE:
- EXISTING PAINTED INTERIOR SURFACES SHALL BE PAINTED. INCLUDING BUT
NOT LIMITED TO WALLS, CEILINGS, TRIM, DOORS, CLOSET INTERIORS AND
CLOSET DOORS, AND EXPOSED WOOD ROOF DECK PLANKS.
- PREPARE ALL SURFACES BY REMOVING EXISTING FASTENERS, ANCHORS OR
OTHER ITEMS. FILL AND PATCH ALL HOLES AND CRACKS. SCRAPE AND REMOVE
FLAKING OR UNADHERED PAINT.
- REFER TO PAINTING SPECIFICATION FOR PAINT SYSTEMS
PAINT COLOR SELECTIONS:
- PNT-1: CEILINGS
- PNT-2: INTERIOR WALLS
- PNT-3: CLOSETS AND SHELVING INTERIORS AND TRIM
C DIMENSIONS PROVIDED ARE APPROXIMATE. ALL DIMENSIONS SHALL BE FIELD
VERIFIED BY CONTRACTOR.
D NEW INTERIOR PARTITION ASSEMBLY SHALL BE 2X4 WOOD FRAMING WITH
1/2" DRYWALL EACH SIDE.
1 NEW CONCRETE PAD FOR CONDENSING UNIT. COORDINATE SIZE WITH
MANUFACTURER RECOMMENDATIONS
2 NEW VENTED FIBER CEMENT SOFFIT PANELS, DASHED LINE INDICATES EXTENT
OF VENTED PANELS.
3 NEW TERRAZZO FINISH ON NEW SLAB INFILL
4 PROVIDE HURRICANE PANELING SYSTEM MATCHING EXISTING DEMOLISHED
SYSTEM. REFER TO NOTES ON A301.
5 REPLACE WOOD ROOF DECK PLANKS WITH NEW PLANKS OF SAME DIMENSION
6 DEMOLISH AND REPLACE EXISTING IN-KIND CLOSET DOORS, HARDWARE AND
SLIDING TRACKS AT EACH CLOSET. REFER TO 2/A401 DETAILS FOR SCOPE AND
ARRANGEMENT.
7 PATCH EXISTING WALL AS REQUIRED FOR INSTALLATION OF ELECTRICAL PANEL
(REFER TO ELECTRICAL)
8 WALL MOUNTED FIRE EXTINGUISHER -- REFER TO SPECIFICATIONS
9 REFER TO HARDWARE SET 10 IN SPECIFICATION SECTION 08 71 00 FOR CLOSET
HARDWARE
2X4 STUD WALL,
FLOOR TO ROOF
DECK PT SILL PLATE,
LEAD BOTH SIDES
WITH FIBER CEMENT
PANEL CLADDING.
NOTE:
NEW WORK AT UNIT
#119 ONLY.
03a
LAUNDRY
PORCH
SCREENED
1/4" = 1' - 0" SCALE OF FEET
0'4' 4' 8'
1 1/2" = 1' - 0" SCALE OF FEET
0'1' 1'6"
0*>�349*8
G*3*7&1�349*8
1*G*3)
A2
A201 A201
A2
0905b
02a
02b
SCALE: BSCALE: A
SCALE: A
B
A
<.3)4<�8-&)*�8(-*):1*
WS-1 ROLLER WINDOW SHADE -- REFER TO SPECIFICATIONS
WS-2L
VERTICAL LOUVER BLINDS -- CONTROL ON RIGHT; DRAW/ STACK ONE
WAY, STACK LEFT; LENGTH TO BE WINDOW OPENING PLUS 1 1/2" --
REFER TO VERTICAL LOUVER BLIND SPECIFICATION
WS-2R
VERTICAL LOUVER BLINDS -- CONTROL ON LEFT; DRAW/ STACK ONE WAY,
STACK RIGHT; LENGTH TO BE WINDOW OPENING PLUS 1 1/2" -- REFER TO
VERTICAL LOUVER BLIND SPECIFICATION
11/21/2022
2' -9
NEW TERRAZZO FINISH
CONCRETE SLAB INFILL
0' -4
0'-4"
3" MIN. #57 STONE
4' x4' WELDED WIRE
MESH REINFORCING
AT MID-POINT OF SLAB
3" MIN. #57 STONE
0' -6
0' -4
HATCHED AREA INDICATES APPROXIMATE EXTENTS OF
NEW TERRAZZO FLOOR FINISH. COORDINATE WITH
EXTENTS OF REQUIRED SLAB DEMOLITION AND INFILL
HATCHED AREA INDICATES APPROXIMATE EXTENTS OF NEW
CEILING FINISH. COORDINATE WITH EXTENTS OF REQUIRED
CEILING DEMO.
A101
01a
05a
03d
04a
04b
04c
03c
03b
03a
SCALE: BA101 A101A101
A PROTECT ALL EXISTING FINISHES FROM DAMAGE DURING THE COURSE OF THE
WORK. PROVIDE PROTECTIVE FLOOR COVERINGS FOR FULL EXTENT OF
INTERIOR FINISH FLOORS. PROTECT CABINETS, APPLIANCES, FIXTURES AND
OTHER EXISTING-TO-REMAIN ITEMS WITH PLASTIC OR OTHER PROTECTIVE
MEANS.
B INTERIOR PAINTING SCOPE:
- EXISTING PAINTED INTERIOR SURFACES SHALL BE PAINTED. INCLUDING BUT
NOT LIMITED TO WALLS, CEILINGS, TRIM, DOORS, CLOSET INTERIORS AND
CLOSET DOORS, AND EXPOSED WOOD ROOF DECK PLANKS.
- PREPARE ALL SURFACES BY REMOVING EXISTING FASTENERS, ANCHORS OR
OTHER ITEMS. FILL AND PATCH ALL HOLES AND CRACKS. SCRAPE AND REMOVE
FLAKING OR UNADHERED PAINT.
- REFER TO PAINTING SPECIFICATION FOR PAINT SYSTEMS
PAINT COLOR SELECTIONS:
- PNT-1: CEILINGS
- PNT-2: INTERIOR WALLS
- PNT-3: CLOSETS AND SHELVING INTERIORS AND TRIM
C DIMENSIONS PROVIDED ARE APPROXIMATE. ALL DIMENSIONS SHALL BE FIELD
VERIFIED BY CONTRACTOR.
D NEW INTERIOR PARTITION ASSEMBLY SHALL BE 2X4 WOOD FRAMING WITH
1/2" DRYWALL EACH SIDE.
1 NEW CONCRETE PAD FOR CONDENSING UNIT. COORDINATE SIZE WITH
MANUFACTURER RECOMMENDATIONS
2 NEW VENTED FIBER CEMENT SOFFIT PANELS, DASHED LINE INDICATES EXTENT
OF VENTED PANELS.
3 NEW TERRAZZO FINISH ON NEW SLAB INFILL
4 PROVIDE HURRICANE PANELING SYSTEM MATCHING EXISTING DEMOLISHED
SYSTEM. REFER TO NOTES ON A301.
5 REPLACE WOOD ROOF DECK PLANKS WITH NEW PLANKS OF SAME DIMENSION
6 DEMOLISH AND REPLACE EXISTING IN-KIND CLOSET DOORS, HARDWARE AND
SLIDING TRACKS AT EACH CLOSET. REFER TO 2/A401 DETAILS FOR SCOPE AND
ARRANGEMENT.
7 PATCH EXISTING WALL AS REQUIRED FOR INSTALLATION OF ELECTRICAL PANEL
(REFER TO ELECTRICAL)
8 WALL MOUNTED FIRE EXTINGUISHER -- REFER TO SPECIFICATIONS
9 REFER TO HARDWARE SET 10 IN SPECIFICATION SECTION 08 71 00 FOR CLOSET
HARDWARE
2X4 STUD WALL,
FLOOR TO ROOF
DECK PT SILL PLATE,
LEAD BOTH SIDES
WITH FIBER CEMENT
PANEL CLADDING.
NOTE:
NEW WORK AT UNIT
#119 ONLY.
03a
LAUNDRY
PORCH
SCREENED
1/4" = 1' - 0" SCALE OF FEET
0'4' 4' 8'
1 1/2" = 1' - 0" SCALE OF FEET
0'1' 1'6"
0*>�349*8
G*3*7&1�349*8
1*G*3)
A2
A201 A201
A2
0905b
02a
02b
SCALE: BSCALE: A
SCALE: A
B
A
<.3)4<�8-&)*�8(-*):1*
WS-1 ROLLER WINDOW SHADE -- REFER TO SPECIFICATIONS
WS-2L
VERTICAL LOUVER BLINDS -- CONTROL ON RIGHT; DRAW/ STACK ONE
WAY, STACK LEFT; LENGTH TO BE WINDOW OPENING PLUS 1 1/2" --
REFER TO VERTICAL LOUVER BLIND SPECIFICATION
WS-2R
VERTICAL LOUVER BLINDS -- CONTROL ON LEFT; DRAW/ STACK ONE WAY,
STACK RIGHT; LENGTH TO BE WINDOW OPENING PLUS 1 1/2" -- REFER TO
VERTICAL LOUVER BLIND SPECIFICATION
11/21/2022
A111
A111
WS-1
WS-1
WS-1
W S-
W
S-
WS-1 WS-1WS-1 WS-1
WS-1 WS-1WS-1 WS-1 WS-1
11'-6"
'-9
HATCHED AREA INDICATES APPROXIMATE EXTENTS OF
NEW TERRAZZO FLOOR FINISH. COORDINATE WITH
EXTENTS OF REQUIRED SLAB DEMOLITION AND INFILL
HATCHED AREA INDICATES APPROXIMATE EXTENTS OF NEW
CEILING FINISH. COORDINATE WITH EXTENTS OF REQUIRED
CEILING DEMO.
A102 SCALE 14" = 1'
A PROTECT ALL EXISTING FINISHES FROM DAMAGE DURING THE COURSE OF THE
WORK. PROVIDE PROTECTIVE FLOOR COVERINGS FOR FULL EXTENT OF
INTERIOR FINISH FLOORS. PROTECT CABINETS, APPLIANCES, FIXTURES AND
OTHER EXISTING-TO-REMAIN ITEMS WITH PLASTIC OR OTHER PROTECTIVE
MEANS.
B INTERIOR PAINTING SCOPE:
- EXISTING PAINTED INTERIOR SURFACES SHALL BE PAINTED. INCLUDING BUT
NOT LIMITED TO WALLS, CEILINGS, TRIM, DOORS, CLOSET INTERIORS AND
CLOSET DOORS, AND EXPOSED WOOD ROOF DECK PLANKS.
- PREPARE ALL SURFACES BY REMOVING EXISTING FASTENERS, ANCHORS OR
OTHER ITEMS. FILL AND PATCH ALL HOLES AND CRACKS. SCRAPE AND REMOVE
FLAKING OR UNADHERED PAINT.
- REFER TO PAINTING SPECIFICATION FOR PAINT SYSTEMS
PAINT COLOR SELECTIONS:
- PNT-1: CEILINGS
- PNT-2: INTERIOR WALLS
- PNT-3: CLOSETS AND SHELVING INTERIORS AND TRIM
C DIMENSIONS PROVIDED ARE APPROXIMATE. ALL DIMENSIONS SHALL BE FIELD
VERIFIED BY CONTRACTOR.
D NEW INTERIOR PARTITION ASSEMBLY SHALL BE 2X4 WOOD FRAMING WITH
1/2" DRYWALL EACH SIDE.
1 NEW CONCRETE PAD FOR CONDENSING UNIT. COORDINATE SIZE WITH
MANUFACTURER RECOMMENDATIONS
2 NEW VENTED FIBER CEMENT SOFFIT PANELS, DASHED LINE INDICATES EXTENT
OF VENTED PANELS.
3 NEW TERRAZZO FINISH ON NEW SLAB INFILL
4 PROVIDE NEW HURRICANE PANELING SYSTEM MATCHING EXISTING
DEMOLISHED SYSTEM. PROVIDE ALL REQUIRED COMPONENTS INCLUDING BUT
NOT LIMITED TO 0.050 THICK, 2" CORRUGATED ALUMINUM PANELS AND
POWDERCOATED ALUMINUM 2" 'H' HEADER TRACK AND STUDDED ANGLE
BOTTOM TRACK, AND ALL REQUIRED FASTENERS.
5 REPLACE WOOD ROOF DECK PLANKS WITH NEW PLANKS OF SAME DIMENSION
6 DEMOLISH AND REPLACE EXISTING IN-KIND CLOSET DOORS, HARDWARE AND
SLIDING TRACKS AT EACH CLOSET. REFER TO 2/A401 DETAILS FOR SCOPE AND
ARRANGEMENT.
7 PATCH EXISTING WALL AS REQUIRED FOR INSTALLATION OF ELECTRICAL PANEL
(REFER TO ELECTRICAL)
8 WALL MOUNTED FIRE EXTINGUISHER -- REFER TO SPECIFICATIONS
9 REFER TO HARDWARE SET 10 IN SPECIFICATION SECTION 08 71 00 FOR CLOSET
HARDWARE
10 24x24 PLYWOOD ACCESS PANEL (PTD) IN DRYWALL CEILING - COORDINATE
FINAL LOCATION WITH WORK IN ATTIC - HEADERS TO MATCH BOTTOM CORD
OF ROOF TRUSS - 1x3 WOOD TRIM (PTD) WITH 1/2" FOAM TAPE ALL SIDES
0*>�349*8
G*3*7&1�349*8
1/4" = 1' - 0" SCALE OF FEET
0'4' 4' 8'
1*G*3)
AREA OF TAPERED INSULATION
ROOF ASSEMBLY TYPE
STANDING SEAM METAL ROOFING
SYSTEM
STANDING SEAM
METAL ROOFING
ROOFING UNDERLAYMENT
32" APA RATED STRUCTURAL
1 SHEATHING
2X8 OVERBUILD
DRILL LINE OF 4" HOLES @ 2'-0"
O.C. FROM EAVE TO RIDGE IN
EACH RAFTER BAY TO PROVIDE
VENTILATION
EXISTING ROOF RAFTER
EXISTING ROOF SHEATHING
MATCH EXISTING SLOPE
NEW 2X8 RAFTER OVERBUILD.
ALIGNED WITH EXISTING RAFTER.
INSECT SCREEN
SBS MODIFIED BITUMEN
ROOFING SYSTEM
2" COVERBOARD
1" INSULATION BASE LAYER,
WITH 18" TAPERED
INSULATION OVERLAY
EXISTING WOOD
ROOF DECK
8" TO 12" SLOPE
SLO
PE
SLO
PE
SLOPE
SLOPE
1 ROOF OVERBUILD FOR FULL EXTENT OF RA-1. INSTALL NEW 2X8 RAFTERS OVER
EXSTING ROOF SHEATHING. ALIGN EACH NEW RAFTER W/EXISTING RAFTER
BELOW. FOR FULL EXTENT OF ROOF ASSEMBLY RA-1 INSTALL 2X8 RAFTER AND
SHEATHING OVERBUILD. TIE NEW RAFTERS TO EXISTING WITH GALVANIZED
METAL TIE PLATE. DRILL GRID OF 4" HOLES AT 2'-0" O.C. IN EXISTING ROOF
SHEATHING ACROSS ENTIRE ROOF AREA TO PROVIDE VENTILATION.
2 REINSTALL EXISTING ROOF VENTILATORS AND FLASHING INTO STANDING SEAM
METAL ROOF
3 ROOF AND STACK VENTS FLASHED INTO STANDING SEAM METAL ROOF -- REFER
TO PLUMBING DRAWINGS
4 LOW PROFILE ROOF VENTS FLASHED INTO STANDING SEAM METAL ROOF --
CENTER IN STANDING SEAM METAL PANELS -- REFER TO MECHANCIAL
DRAWINGS
SL
O
PE
SLOPE
SL
O
PE
SLO
PE
SLO
PE
A DOCUMENT EXISTING CONDITION OF ROOF RAFTERS AND ROOF SHEATHING
AFTER DEMOLITION OF EXISTING ROOFING MATERIOALS AND PRIOR TO
CARRYING OUT NEW WORK. PROVIDE DOCUMENTATION OF EXISTING
CONDITIONS TO CONTRACT OFFICER FOR REVIEW AND CONFIRMATION OF NEW
WORK DESIGN AND APPROACH.
B ROOF ASSEMLBY RA-2 TO HAVE 1/8-INCH PER FOOT SLOPE WITH TAPERED
INSULATION ON TOP OF 1-INCH BASE LAYER
SLOPE
0*>�349*8
G*3*7&1�349*8
1*G*3)
A103 SCALE: B A103 SCALE: B
1/4" = 1' - 0" SCALE OF FEET
0'4' 4' 8'
1 1/2" = 1' - 0" SCALE OF FEET
0'1' 1'6" B
A
A103 SCALE: A
2" COVERBOARD
1" INSULATION
MODIFIED BITUMEN
ROOFING SYSTEM
PT WOOD BLOCKING
METAL DRIP EDGE
W/CLEAT
EXISTING ROOF
CONSTRUCTION
PT WOOD BLOCKING
FIBER CEMENT
FASCIA TRIM, 6", PAINTED.
VENTED FIBER CEMENT
SOFFIT PANEL, PAINTED
SECURE INSECT SCREEN
TO TOP SIDE OF SOFFIT
VENT CONTINUOUS
2" COVERBOARD
1" INSULATION
MODIFIED BITUMEN
ROOFING SYSTEM
PT WOOD BLOCKING
METAL DRIP EDGE
W/CLEAT
EXISTING ROOF
CONSTRUCTION
FIBER CEMENT FASCIA
TRIM, PAINTED
32" APA RATED STRUCTURAL
PLYWOOD SHEATHING
STANDING SEAM
METAL ROOF SYSTEM
METAL FLASHING TRIM
W/DRIP EDGE
MODIFIED BITUMEN
ROOFING SYSTEM
2" COVERBOARD
1" INSULATION
EXISTING ROOF DECK
ROOFING UNDERLAYMENT
2X8 RAFTER OVERBUILD, ALIGN
EACH NEW RAFTER W/EXISTING
ROOF RAFTER.
CUT STRIP IN EXISTING ROOF
SHEATHING. DRILL LINE OF 4"
HOLES AT 2'-0" O.C. FROM EAVE
TO RIDGE IN EACH RAFTER BAY
TO PROVIDE VENTILATION.
VENTED FIBER-CEMENT SOFFIT
PANEL. ENSURE CONTINUOUS
PATH OF AIRFLOW FROM SOFFIT
VENT TO RIDGE.
2X8, CONTINUOUS
TIE NEW AND EXISTING RAFTERS
TOGETHER WITH GALVANIZED
METAL SPLICE PLATE AT 4'-0" O.C.
INSECT SCREEN
STANDING SEAM METAL
ROOFING SYSTEM
METAL ROOF PANEL
SYSTEM GABLE-END TRIM
FIBER CEMENT FASCIA
TRIM, 8", PAINTED
ROOF UNDERLAYMENT
32" STRUCTURAL PLYWOOD
2X8 RAFTER OVERBUILD
PT WOOD SHIMS
FIBER CEMENT FASCIA
TRIM, 4", V.I.F
FIBER CEMENT VENTED
SOFFIT PANEL
TIE NEW AND EXISTING
RAFTERS TOGETHER WITH
GALVANIZED METAL SPLICE
PLATE AT 4'-0" O.C.
VENTED RIDGE CAP
STANDING SEAM
METAL ROOF SYSTEM
ROOFING UNDERLAYMENT
33" APA RATED STRUCTURAL 1
SHEATHING
NEW 2X8 RAFTER OVERBUILD,
ALIGNED WITH EXISTING RAFTER
EXISTING RAFTER AND
SHEATHING
TIE NEW AND EXISTING RAFTERS
TOGETHER WITH GALVANIZED
METAL SPLICE PLATE AT 4'-0" O.C.
1 1/2" = 1' - 0" SCALE OF FEET
0'1' 1'6"
A EXTERIOR PAINTING SCOPE:
▪ ALL EXISTING PAINTED EXTERIOR SURFACES SHALL BE PREPARED AND PAINTED
INCLUDING BUT NOT LIMITED TO CLADDING PANELS, WINDOW TRIM, DOOR
FRAMES, SOFFITS, ROOF OVERHANGS AND ROOF DECKS.
▪ PREPARE ALL SURFACES BY REMOVING EXISTING UNUSED FASTENERS,
ANCHORS OR OTHER ITEMS. REMOVE FLAKING OR UNADHERED PAINT. CLEAN
SURFACES IN ACCORDANCE WITH PAINT MANUFACTURERS
RECOMMENTATIONS.
▪ PAINT COLORS ARE TO BE DETERMINED:
▪ PNT-4: CLADDING/SIDING PANELS
▪ PNT-5: TRIM, SOFFITS, ROOF OVERHANGS
B WINDOWS WILL BE REPLACED BY SEPARATE CONTRACTOR UNDER SEPARATE
CONTRACT. PROTECT WINDOWS FROM DAMAGE DURING THE COURSE OF THE
WORK.
C AT SCREEN WALL SW-1, INSTALL 1" THICK PT BOARDS, BETWEEN OPENINGS, ON
EXTERIOR SIDE. BOARDS TO RUN FULL HEIGHT AND PLACED ON THE EXTERIOR
SIDE OF EXISTING METAL PANEL. PAINT TO MATCH FAÇADE.
1 UNIT #119 ONLY: FIBER CEMENT LAP SIDING IN GABLE END OVER
BUILDING-WRAP MEMBRANE AND SUBSTRATE
2 EXISTING WINDOW, TYPICAL
3 EXISTING FIBER CEMENT PANEL CLADDING, TYPICAL, PAINTED.
4 EXISTING MASONRY CLADDING, TYPICAL, PRESSURE WASH ALL FACES TO CLEAN.
5 EXISTING ROOF BEAMS AND OVERHANG, PAINTED.
SW-1
SW-2
0*>�349*8
G*3*7&1�349*8
1/4" = 1' - 0" SCALE OF FEET
0'4' 4' 8'
SCREEN
MESH
METAL
PANEL
R E
F.
S
C H
E D
U
LE
REF. SCHEDULE
1/
2" 5"
REF. SCHEDULE
R E
F.
S
C H
E D
U
LE
REF. SCHEDULE
R E
F.
S
C H
E D
U
LE
MATCH\EXTG
M A
TC
H
\E X
TG
M
A
TC
H \E
X
TG
REF. SCHEDULE
R E
F.
S
C H
E D
U
LE
L1 5"F
S L2
LOUVERLOUVER
SCREEN
MESH
REF. SCHEDULE
R E
F.
S
C H
E D
U
LE
L3
CLEAR GLASS
METAL
PANEL
DOOR SCHEDULE
NUMBER
DOOR FRAME DETAILS
FIRE RATING HDWRNEW/ EXIST FINISH
SIZE
NEW/ EXIST TYPE MAT'L JAMBWIDTH HEIGHT THICKNESS
PINE ISLAND 119, 120, 124
01a NEW F FIBERGLASS PF 2'-6" 6'-8" 1 3/8" EXIST - WOOD PAINTED H1 J1 S1 - 1
01b NEW L3 ALUM/GLASS PF 2'-6" 6'-8" - NEW - ALUM PAINTED - - - - -
03a NEW - FIBERGLASS - 2'-6" 6'-8" 1 3/8" EXIST - WOOD PAINTED - - - - - FIELD VERIFY DOOR WIDTH
03b NEW - FIBERGLASS - 5'-0" 6'-8" 1 3/8" EXIST - WOOD PAINTED - - - - -
03c NEW S ALUM - 2'-6" 6'-8" - NEW SW1 ALUM - - - - - 9 BY SCREEN ENCLOSURE MANUF
03d NEW S ALUM - 2'-6" 6'-7" - NEW SW3 ALUM - - - - - 9 BY SCREEN ENCLOSURE MANUF
04a NEW F FIBERGLASS PF 6'-0" 6'-8" 1 3/4" NEW - HM PAINTED H2 J2 - - 4
04b NEW F FIBERGLASS PF 6'-0" 6'-8" 1 3/4" NEW - HM PAINTED H2 J2 - - 4
04c NEW F FIBERGLASS PF 6'-0" 6'-8" 1 3/4" NEW - HM PAINTED H2 J2 - - 4
05a NEW L2 WOOD PAINTED 4'-0" 6'-8" 1 3/8" NEW - WOOD PAINTED - - - - -
05b NEW L1 WOOD PAINTED 2'-6" 6'-8" 1 3/8" NEW - WOOD PAINTED - - - - -
06 NEW L2 WOOD PAINTED 2'-0" 6'-8" 1 3/8" NEW - WOOD PAINTED - - - - 7
07 NEW L2 WOOD PAINTED 2'-6" 6'-8" 1 3/8" NEW - WOOD PAINTED - - - - 7
08 NEW L2 WOOD PAINTED 2'-6" 6'-8" 1 3/8" EXIST - WOOD PAINTED - - - - 8
09 NEW L2 WOOD PAINTED 2'-6" 6'-8" 1 3/8" EXIST - WOOD PAINTED - - - - 8
10 NEW L2 WOOD PAINTED 2'-6" 6'-8" 1 3/8" EXIST - WOOD PAINTED - - - - 8
TYPE MAT'L FINISH HEAD SILL COMMENTS
FULL-LITE DOOR
BI-FOLD W/ WOOD KNOB PULL
FIELD VERIFY DOOR WIDTH, ADD LOUVERS
08,09,10 CLO NEW L2 WOOD PAINTED 3'-6" 6'-8" 1 3/8" NEW - WOOD PAINTED - - - - - BI-FOLD BEDROOM CLOSET W/ WOOD KNOB PULL
3'-0" 2'-6" 2'-0"
3' -0
1'
-4
2' -6
WOOD VENEERED WALL
CABINET WITH ADJ
SHELF, TYPICAL
WOOD VENEERED BASE
CABINETS WITH ADJ
SHELF, TYPICAL
RECEPTACLE, REFER
TO ELECTRICAL.
1-1/2" SOLID SURFACE
COUNTERTOP AND
BACKSPLASH
1' -0
FILLER STRIP AS REQ.
PROVIDE BLOCKING
FOR WALL HUNG MW-01
RANGE
RW-02
MICROWAVE
MW-01
FILLER STRIP AS REQ.
RANGE
RW-02
KITCHEN
BATHROOM
PWDR ROOM
DW-01
RG-02
RF-01
026' -4
1'-111 4" 2'-0"
7' -9
7' -6
WOOD VENEERED
WALL CABINET W/
ADJ SHELF, TYP.
1'-3" 3'-0" 2'-0" 1'-6"
3' -0
1'
-4
2' -6
" RECEPTACLE MOUNTED
IN BACKSPLASH. REFER
TO ELECTRICAL.
1-1/2" SOLID SURFACE
COUNTERTOP AND
BACKSPLASH
DW-01
WOOD VENEERED BASE
CABINETS WITH ADJ
SHELF, TYPICAL
3' -6
1'-5"
FILLER STRIP AS
REQUIRED
1'-3"
FINISHED CABINET END
7'-9"
4' -3
EQ
EQ
4'-3" (VIF)
5' -7
1'
-6
7' -1
0"
(V
IF
0'-3"
REF HARDWARE SET 10 IN
SPECIFICATION SECTION 08 71 00
INTERMEDIATE SHELF - MATCH
EXISTING CLOSET SHELVING
CONSTRUCTION
0' -4
NEW SLIDING WOOD DOORS
0' -5
REF HARDWARE SET 10 IN
SPECIFICATION SECTION 08 71 00
A401 SCALE 12" = 1' A401 SCALE 12" = 1'
A401 SCALE 12" = 1'
A401 A401
A401 SCALE 12" = 1'
1 DASHED LINE INDICATES EXTENT OF NEW WALL TILE (WT-1) -- INSTALL TILE
OVER BACKERBOARD. MATCH EXISTING TILE HEIGHT OF +/- 46" AFF. VERIFY IN
FIELD. PROVIDE BULLNOSE UNITS AT ALL EDGES.
2 FIBERGLASS TUB/SHOWER, REF PLUMBING.
3 SINK VANITY CABINET WITH SOLID SURFACE TOP.
4 WALL CABINET, REFER TO SPECIFICATIONS
METAL BRACKETS
BELOW COUNTER,
TYP. OF (3)
KNEE WALL
BELOW
WOOD CLOSET ROD AND
BRACKETS - MATCH EXTG
CLOSET CONSTRUCTION
NEW PAINT-GRADE PLYWOOD
BOTTOM IN CLOSET ON 2X WOOD
FRAMING. MATCH HEIGHT A.F.F
OF EXISTING CLOSETS
1/2" = 1' - 0" SCALE OF FEET
0'1' 3'6" 2'1'
0*>�349*8
T1 METAL SHOWER CURTAIN ROD, EXPANDING TENSION, TYP.
T2 30" TOWEL BAR
T3 TOILET TISSUE HOLDER
T4 ROBE HOOK - MOUNT ON BACK OF DOOR
T5 12" TOWEL BAR
T6 MEDICINE CABINET WITH MIRROR, REFER TO SPECIFICATIONS
94.1*9�&((*8847.*8��7*+�85*(.+.(&9.438�
A401 SCALE 12" = 1'
ALIGN INTERIOR PARTITION
WITH EXISTING WALL - WOOD
BASE ON CORRIDOR SIDE TO
MATCH EXISTING PROFILE
MB
SS
1/4"=1'-0"
PLUMBING DEMOLITION PLAN - BLDG. 1191
PD101
DEMOLISH EXTERIOR SUPPLY AND WASTE PIPING ASSOCIATED WITH
EXISTING EQUIPMENT. WASTE PIPING SHALL BE REMOVED TO A POINT
FIVE FOOT OUTSIDE THE BUILDING OR AT THE YARD CLEANOUT.
WASTE PIPING SHALL BE TEMPORARILY CAPPED UNTIL MODIFICATION
PORTION OF THE PROJECT. SUPPLY PIPING SHALL BE REMOVED TO A
POINT FIVE FOOT OUTSIDE THE BUILDING AND BE TEMPORARILY
CAPPED UNTIL MODIFICATION PORTION OF THE PROJECT.
DEMOLISH ALL SUPPLY, WASTE AND VENT PIPING AND ASSOCIATED
APPURTENANCES WITH THE ROOM INCLUDING PIPING IN THE WALLS,
ABOVE THE CEILING AND BELOW SLAB (WALLS, CEILINGS AND SLAB
REMOVED BY OTHERS). WASTE AND VENT PIPING SHALL BE REMOVED
TO A POINT BELOW FLOOR/ABOVE CEILING. SUPPLY AND WASTE
PIPING SHALL BE REMOVED TO THE EXTERIOR. VENT PIPING SHALL BE
REMOVED TO THE VENT THRU ROOF. VENT THRU ROOF SHALL BE
REMOVED AND HOLE IN THE ROOF SHALL BE TEMPORARILY
CAPPED/PLUGGED UNTIL MODIFICATION PORTION OF THE PROJECT.
DEMOLISH ALL SUPPLY, WASTE AND VENT PIPING AND ASSOCIATED
APPURTENANCES CONNECTED TO THE WASHING MACHINE. SEE
DEMOLITION NOTE 2 FOR ADDITIONAL INFORMATION.
REMOVE AND LEGALLY DISPOSE OF EXISTING WATER HEATER,
ANCILLARY TRIM AND PIPING (SUPPLY AND DWV). SEE DEMOLITION
NOTE 2 FOR ADDITIONAL INFORMATION.
REMOVE AND LEGALLY DISPOSE OF EXISTING LAVATORY, ANCILLARY
TRIM AND PIPING (SUPPLY AND DWV). SEE DEMOLITION NOTE 2 FOR
ADDITIONAL INFORMATION.
REMOVE AND LEGALLY DISPOSE OF EXISTING KITCHEN SINK,
ANCILLARY TRIM AND PIPING (SUPPLY AND DWV). SEE DEMOLITION
NOTE 2 FOR ADDITIONAL INFORMATION.
REMOVE AND LEGALLY DISPOSE OF EXISTING TANK-TYPE WATER
CLOSET AND PIPING (SUPPLY AND DWV). SEE DEMOLITION NOTE 2 FOR
ADDITIONAL INFORMATION.
REMOVE AND DEMOLISH EXISTING SHOWER ASSEMBLY AND
ANCILLARY TRIM AND PIPING (SUPPLY AND DWV). SEE DEMOLITION
NOTE 2 FOR ADDITIONAL INFORMATION.
GENERAL NOTE:
DEMOLISH ALL HOT AND COLD WATER AND DWV PIPING THROUGHOUT
THE BUILDING. SUPPLY AND WASTE PIPING SHALL BE REMOVED TO THE
EXTERIOR. ALL PLUMBING FIXTURES AND EQUIPMENT AND PIPING
(INCLUDING IN WALLS, ABOVE CEILING AND BELOW SLAB) SHALL BE
REMOVED FROM THE BUILDING AND LEGALLY DISPOSED OF. NOT ALL
PIPING LOCATIONS MAY BE SHOWN WITH HATCHING. DEMOLISH ALL
PIPING IN BUILDING.
SEE DRAWING P-001 FOR PROJECT PLUMBING DEMOLITION NOTES AND
ADDITIONAL GENERAL DEMOLITION NOTES.
DEMOLISHED PIPING, FIXTURES AND APPURTENANCES ARE
REPRESENTED BY HATCHED DESIGNATION AND/OR KEYED NOTE.
DEMOLISH ALL HOT AND COLD WATER AND DWV PIPING THROUGHOUT
THE BUILDING. SUPPLY AND WASTE PIPING SHALL BE REMOVED TO THE
EXTERIOR. ALL PLUMBING FIXTURES AND EQUIPMENT AND PIPING
(INCLUDING IN WALLS, ABOVE CEILING AND BELOW SLAB) SHALL BE
REMOVED FROM THE BUILDING AND LEGALLY DISPOSED OF. NOT ALL
PIPING LOCATIONS MAY BE SHOWN WITH HATCHING. DEMOLISH ALL
PIPING IN BUILDING.
COORDINATE WITH GENERAL CONTRACTOR ON DEMOLITION OF WALLS,
CEILINGS AND FLOOR SLABS AS NEEDED.
3.)
1.)2.)
4.)
LEGEND
KEY NOTES
GENERAL NOTES
1/4" = 1' - 0" SCALE OF FEET
0'4' 4' 8'
MB
PROJECT PLUMBING NOTES
GENERAL NOTES: (DWG P-001 - P-301)
MB
MB
SS
V
PLBG ABBREVIATION LEGEND
CW
HW
W
SAN
T
PIPE SYMBOL LEGEND
SAN
SS
SS
V
C/A
30-240
DEG.F
0-100
PSIG
MB
05a
CLOSET
BEDROOM A
BEDROOM B
BEDROOM C
CORRIDOR
ROOM
LIVING
PORCH
SCREENED
KITCHEN
BATHROOM
ROOM
POWDER
03a
LAUNDRY
PORT
CAR
04a
CLOSET
1/4"=1'-0"
PLUMBING PLAN - BLDG. 1191
P-101
SEE DRAWING P-001 FOR PROJECT PLUMBING NOTES.
COLD AND HOT WATER PIPING AND VENT PIPING ARE LOCATED ABOVE
CEILING AND SANITARY PIPING IS LOCATED BELOW SLAB ON GRADE,
EXCEPT WHERE NOTED OTHERWISE.
SEE ARCHITECTURAL DRAWINGS FOR ELEVATIONS AND TOILET ROOM
FIXTURE HEIGHTS.
COORDINATE WITH GENERAL CONTRACTOR ON WALL FURR-OUT
LOCATIONS FOR HOSE BIBB DROPS.
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ASSIGNMENT OF
ALL WALL/FLOOR/CEILING CUTTING AND PATCHING REQUIRED FOR THIS
TRADE WORK. FINAL FINISH ASSIGNED BY GENERAL CONTRACTOR.
2.)
1.)
3.)
4.)
5.)
NEW WATER SERVICE. WATER SERVICE WILL SERVE BOTH DOMESTIC COLD
WATER AND FIRE PROTECTION (SPRINKLER). INSTALL NEW RPZ BACKFLOW
PREVENTER (SIMILAR TO WATTS 009-LF WITH STRAINER) INSIDE BUILDING.
TAKE THE DRAIN FROM THE RPZ TO THE OUTSIDE.
ROUTE NEW 2" SANITARY FROM WASHER SERVICE BOX OUTSIDE AND
CONNECT TO NEW 4" SANITARY MAIN. INSTALL NEW VENT PIPING AND VENT
THRU ROOF FOR WASHER SERVICE BOX. COORDINATE WITH GENERAL
CONTRACTOR FOR LOCATION AND ROOF WORK.
INSTALL NEW WATER SHUT-OFF VALVE WITHIN 5 FOOT OF BUILDING.
COORDINATE LOCATION WITH MECHANICAL CONTRACTOR AND NEW HVAC
EQUIPMENT.
ARCHITECTURAL PROVIDED LAVATORY. INSTALL THERMOSTATIC MIXING
VALVE UNDER LAVATORY. SEE PLUMBING EQUIPMENT/FITTINGS SCHEDULE
ON P-301 FOR ADDITIONAL INFORMATION.
INSTALL NEW VENT THRU ROOF IN THE LOCATION OF THE OLD VENT THRU
ROOF. ROUTE AND CONNECT NEW VENT PIPING TO NEW VENT THRU ROOF.
COORDINATE INSTALLATION OF VENT THRU ROOF WITH GENERAL
CONTRACTOR AND THE ROOF REPLACEMENT.
1-1/2" VENT PIPING AND 1/2" HOT AND COLD WATER PIPING BELOW FLOOR.
WATER SERVICE TO BE ROUTED OVERHEAD TO CARPORT CLOSET. INSTALL
HOSE BIBB WITH SHUT-OFF VALVE. FIRE PROTECTION (SPRINKLER) WILL
SEPARATE IN CLOSET. SEE FIRE PROTECTION DRAWINGS FOR CONTINUATION.
WASHER SERVICE BOX (WSB) TO BE SURFACE MOUNTED.
LEGEND
KEY NOTES
GENERAL NOTES
1/4" = 1' - 0" SCALE OF FEET
0'4' 4' 8'
MB
SEE DRAWING P-001 FOR PROJECT PLUMBING NOTES.
SEE ARCHITECTURAL DRAWINGS FOR ELEVATIONS AND TOILET ROOM
FIXTURE HEIGHTS.
2.)
1.)
INSTALL NEW VENT THRU ROOF IN THE LOCATION OF THE OLD VENT THRU
ROOF. ROUTE AND CONNECT NEW VENT PIPING TO NEW VENT THRU ROOF.
COORDINATE INSTALLATION OF VENT THRU ROOF WITH GENERAL
CONTRACTOR AND THE ROOF REPLACEMENT.
LEGEND
KEY NOTES
GENERAL NOTES
MB
AND 80 STEEL PIPING
HORIZONTAL SCHEDULE 40
HORIZONTAL SCHEDULE 40
AND 80 PVC OR ABS PIPING
3/8"1/2" 5'
2-1/2"
1-1/2"
1-1/4"
5/8"
3/4"
7'
3"
2"
10'
8'
8'
1"
7'
6'
5'
5'
3/8"
1/2"
1/2"
3/8"
3/8"
3/8"
3/8"
3/8"
1/2"-2" 4'
2-1/2"-3"
6"-8"
4"
4'
4'
4'
PIPE
SIZE
HANGER
SPACING
SUPPORT
SPACING
NOTE: ALL PIPING 1" AND LARGER SHALL BE
SUPPORTED AT EACH FLOOR PENETRATION
ROD DIAMETER
HORIZONTAL COPPER
PIPING (ALL TYPES)
12'
15'
10'
ALL TYPES AND SIZES
VERTICAL PIPING
3/8"
PIPE
SIZE SPACING
HANGER
4'
4" - 14"
1" - 1-1/2"
2" - 2-1/2"
1/2"-3/4"
3/8"
3"
SIZE
PIPE
1/4"
HANGER
14"
6"-8"
10"-12"
4"-5"
12'
12'
12'
12'
3"
2-1/2"
2"
1-1/2"
1-1/4"
12'
11'
10'
9'
8'4'
8'
6'
SIZE
PIPE
SPACING
HANGER PLATE LUGS SHALL BE MSS TYPE 57.
ALL RIGID RODS HANGERS SHALL HAVE A MEANS
FOR VERTICAL ADJUSTMENT AFTER ERECTION.
HANGER INSPECTIONS SHALL BE PERFORMED IN
ACCORDANCE WITH MSS-SP89 (SECTION 7.7) AND
ASME B31.1 (APPENDIX V).
WHERE INDICATED AS ACCEPTABLE, GROOVED PIPING
SYSTEM HANGERS AND SUPPORTS SHALL BE
DESIGNED AND LAYED OUT BY THE GROOVED PIPE
SYSTEM MANUFACTURER. DRAWINGS SHALL BE
SUBMITTED TO THE ENGINEER PRIOR TO
INSTALLATION.
CUT OFF EXCESS THREADED ROD AFTER HANGER
ADJUSTMENTS HAVE BEEN MADE.
PIPE HANGERS AND SUPPORTS SHALL NOT BE
ATTACHED TO UPPER FLOOR OR ROOF, METAL
DECKING.
SEE SEPARATE ROOF SUPPORT DETAIL FOR ROOF
SUPPORT REQUIREMENTS. SPACING OF ROOF PIPE
SUPPORTS VARY FROM THOSE INDICATED HEREIN.
PIPE HANGER AND SUPPORT NOTES
PIPE HANGERS , SUPPORTS AND COMPONENTS
SHALL BE MSS SP-58, FACTORY-FABRICATED
COMPONENTS.
POWDER-ACTUATED DRIVE-PIN FASTENERS SHALL
HAVE PULL-OUT AND SHEAR CAPACITIES
APPROPRIATE FOR THE SUPPORTED LOADS AND
BUILDING MATERIALS WHERE USED.
MECHANICAL-ANCHOR FASTENERS SHALL BE
INSERT-TYPE WITH PULL-OUT AND SHEAR
CAPACITIES APPROPRIATE FOR THE SUPPORTED
LOADS AND BUILDING MATERIALS WHERE USED.
STRUCTURAL STEEL CROSS MEMBERS, SUPPORTS
AND BRACING SHALL BE ASTM A36/A 36M, STEEL
PLATES, SHAPES, AND BARS. STEEL MEMBERS SHALL
BE PAINTED OR GALVANIZED.
CHANNEL SUPPORT SYSTEMS SHALL BE MFMA-2,
FACTORY-FABRICATED COMPONENTS FOR FIELD
ASSEMBLY AS MANUFACTURED BY GRINNELL, B-LINE
OR EQUAL.
TOP BEAM C-CLAMPS SHALL BE MSS TYPE 19.
SIDE BEAM OR CHANNEL CLAMPS SHALL BE MSS
TYPE 20.
CENTER-BEAM CLAMPS SHALL BE MSS TYPE 21.
C-CLAMPS SHALL BE MSS-23
WELDED STEEL BRACKETS SHALL BE MSS TYPE 31
FOR UP TO 750 LB LOADS, MSS TYPE 32 FOR UP
TO 1500 LBS AND MSS TYPE 33 FOR LOADS UP
TO 3000 LBS.
SIDE-BEAM BRACKETS SHALL BE MSS TYPE 34.
3/8"
1/2"-5/8"
3/4"
1/2"
ROD DIAMETER
HANGER
10.)
11.)
9.)
8.)
7.)
1/2"
1"
3/4"
7/8"
5/8"
1/2"
3/8"
3/8"
3/8"
6.)
5.)
4.)
ROD DIAMETER
HANGER
3.)
2.)
1.)
16.)
15.)
14.)
13.)
12.)
PIPE HANGERS AND PIPE CLAMP DETAILS AND NOTES (SEE SECTION 15060)
GALVANIZED STEEL RODS
THREADED AT EACH END
ANCHORED TO STRUCTURE
ABOVE. ALL-THREAD ROD
MAY BE USED FOR RODS 24"
AND SHORTER.
GALVANIZED STEEL CLEVIS
HANGER. GRINNELL FIG. 260
OR EQUAL.
INSULATED STEEL OR COPPER
PIPE.
24" LONG 14 GAGE 180°
GALV. STEEL PROTECTION
SADDLE
TREATED WOOD BLOCK
GALVANIZED STEEL RISER CLAMP.
GRINNELL FIG. 261 OR EQUAL.
FOUR (4) STEEL SHEAR LUGS
WELDED TO SIDE OF PIPE. LUGS
TO BE 3"L X 1.5" X .25" FOR
PIPING 6" AND SMALLER. USE 4"H
X 2" X .375" FOR PIPING 8"-14"
STEEL PIPE.
INSULATE CLAMP ON COLD PIPING
TO REDUCE CONDENSATION.
GALVANIZED STEEL RODS
THREADED AT EACH END
ANCHORED TO STRUCTURE
ABOVE. ALL-THREAD ROD
MAY BE USED FOR RODS
24" AND SHORTER.
GALVANIZED STEEL CLEVIS
HANGER. GRINNELL FIG. 260
OR EQUAL.
INSULATED COPPER PIPE.
18" LONG 16 GAGE 180°
GALV. STEEL PROTECTION
SADDLE
GALVANIZED STEEL RODS
THREADED AT EACH END
ANCHORED TO STRUCTURE
ABOVE. ALL-THREAD ROD
MAY BE USED FOR RODS
24" AND SHORTER.
GALVANIZED STEEL CLEVIS
HANGER. GRINNELL FIG. 65
OR EQUAL.
INSULATED COPPER PIPE
12" LONG 18 GAGE 180°
GALV. STEEL PROTECTION
SADDLE
INSULATED PIPE - NOMINAL PIPE SIZE THRU 2"
INSULATED PIPE - NOMINAL PIPE SIZE THRU 1-1/2"
GALVANIZED STEEL ALL-THREAD
ROD ANCHORED TO STRUCTURE
ABOVE. ALL-THREAD ROD MAY
BE USED FOR RODS 24" AND
SHORTER.
PLASTIC COATED PLATED STEEL
PIPE RING HANGER. GRINNELL
FIG. CT-99C OR EQUAL.
INSULATED COPPER PIPE.
12" LONG 18 GAGE 180° GALV.
STEEL PROTECTION SADDLE
NOMINAL PIPE SIZE - 3/4" THRU 3" NOMINAL PIPE SIZE - 4" THRU 14"
INSULATED PIPE - NOMINAL PIPE SIZE 6" THRU 8"
GALVANIZED STEEL RISER CLAMP.
GRINNELL FIG. 261 OR EQUAL.
STEEL OR PVC PIPE.
INSULATE CLAMP ON COLD
PIPING TO REDUCE
CONDENSATION.
INSULATED PIPE - NOMINAL PIPE SIZE 1" THRU 4" INSULATED PIPE - NOMINAL PIPE SIZE 8" THRU 12"
GALVANIZED STEEL ALL-THREAD
ROD ANCHORED TO STRUCTURE
ABOVE. ALL-THREAD ROD MAY
BE USED FOR RODS 24" AND
SHORTER.
PLATED STEEL PIPE RING
HANGER. GRINNELL FIG. 69 OR
EQUAL.
INSULATED COPPER PIPE
12" LONG 18 GAGE 180° GALV.
STEEL PROTECTION SADDLE
PLASTIC COATED COPPER FINISHED
RISER CLAMP. GRINNELL FIG.
CT-121C OR EQUAL.
COPPER PIPE.
INSULATE CLAMP ON COLD PIPING
TO REDUCE CONDENSATION.
NOMINAL PIPE SIZE - .75" THRU 4"
GALVANIZED U-BOLT PIPE
CLAMP. GRINNELL FIG. 137
OR EQUAL.
UNINSULATED STEEL OR PVC
PIPE.
12 GAGE MOUNTING
CHANNEL. GRINNELL
POWERSTRUT OR EQUAL.
INSULATED PIPE - PIPE O.D. 1/2" THRU 8"
SHOP FABRICATED 18 GAGE
12" LONG 170° PROTECTION
SADDLE GLUED IN PLACE
(TOP AND BOTTOM)
TWO PIECE GALVANIZED PIPE
CLAMPS. GRINNELL MODEL
PS 1200 OR EQUAL.
INSULATED STEEL OR
COPPER PIPE.
12 GAGE MOUNTING
CHANNEL. GRINNELL
POWERSTRUT OR EQUAL.
NOMINAL PIPE SIZE .375" THRU 4"
TWO PIECE GALVANIZED PIPE
CLAMPS. GRINNELL MODEL PS
1200 OR EQUAL.
UNINSULATED STEEL OR PVC
PIPE.
12 GAGE MOUNTING CHANNEL.
GRINNELL POWERSTRUT OR
EQUAL.
NOMINAL PIPE SIZE .375" THRU 3"
TWO PIECE GALVANIZED
PIPE CLAMP WITH RUBBER
CUSHION. GRINNELL
MODEL PS 1400 OR
EQUAL.
UNINSULATED COPPER
PIPE.
12 GAGE MOUNTING
CHANNEL. GRINNELL
POWERSTRUT OR EQUAL.
NOMINAL PIPE SIZE 4" THRU 14"
GALVANIZED STEEL RODS
THREADED AT EACH END
ANCHORED TO STRUCTURE
ABOVE. ALL-THREAD ROD
MAY BE USED FOR RODS
24" AND SHORTER.
GALVANIZED STEEL CLEVIS
HANGER. GRINNELL FIG. 260
OR EQUAL.
UNINSULATED STEEL OR PVC
PIPE.
GALVANIZED STEEL ALL-THREAD
ROD ANCHORED TO STRUCTURE
ABOVE. ALL-THREAD ROD MAY
BE USED FOR RODS 24" AND
SHORTER.
PLASTIC COATED PLATED STEEL
PIPE RING HANGER. GRINNELL
FIG. CT-99C OR EQUAL.
UNINSULATED COPPER PIPE.
NOMINAL PIPE SIZE .375" THRU 3" NOMINAL PIPE SIZE 2.5" THRU 4"
GALVANIZED STEEL ALL-THREAD
ROD ANCHORED TO STRUCTURE
ABOVE. ALL-THREAD ROD MAY
BE USED FOR RODS 24" AND
SHORTER.
PLATED STEEL PIPE RING
HANGER. GRINNELL FIG. 69 OR
EQUAL.
UNINSULATED STEEL OR PVC
PIPE.
NOMINAL PIPE SIZE .375" THRU 2"
GALVANIZED STEEL RODS
THREADED AT EACH END
ANCHORED TO STRUCTURE
ABOVE. ALL-THREAD ROD
MAY BE USED FOR RODS
24" AND SHORTER.
GALVANIZED STEEL CLEVIS
HANGER. GRINNELL FIG. 65
OR EQUAL.
UNINSULATED STEEL OR
PVC PIPE.
NOMINAL PIPE SIZE 5" THRU 12"
NOTE: PIPE INSULATION TO BE CONTINUOUS THRU
PIPE HANGERS/BRACKETS.
17.)
18.)
P-201
.5" HIGH LETTERS (MINIMUM)
8" OR LONGER SNAP-ON OR WRAP-AROUND
POLYESTER LABELS WITH ADHESIVE STRIP(S).
FLOW DIRECTION ARROW
DOMESTIC HOT WATER
PLUMBING PIPING LABELING DETAILS
BACKGROUND
COLOR
LABEL TEXT AND COLOR LEGEND
1.25" O.D. AND SMALLER PIPING. (O.D. INCLUDES INSULATION WHERE REQUIRED)
BLACK
BLACK
WHITE
WHITE
WHITE
WHITE
BLACK
BLACK
BLACK
WHITE
ACID VENT
ACID WASTE
CITY WATER
COMPRESSED AIR
DEIONIZED WATER
DOMESTIC COLD WATER
DOMESTIC HOT WATER*
DOMESTIC HOT WATER
RETURN
NATURAL OR LP GAS
SANITARY DRAIN
PIPE SYSTEM
DESCRIPTION
LETTER
COLOR
DOMESTIC HOT WATER
RED
GREEN
YELLOW
WHITE
BLACK
BLUE
GREEN
WHITE
WHITE
BLACK
BLACK
WHITE
WHITE
WHITE
YELLOW
YELLOW
GREEN
BLUE
GREEN
GREEN
YELLOW
YELLOW
YELLOW
GREEN
SPRINKLER-FIRE
STORM
MEDICAL AIR
MEDICAL VACUUM
NITROGEN
NITROUS OXIDE
OXYGEN
NOT TO SCALE
PIPE SYSTEM
DESCRIPTION
BACKGROUND
COLOR
LETTER
COLOR
2" TO 6" O.D. PIPING AND ABOVE. (O.D. INCLUDES INSULATION WHERE REQUIRED)
1.5" O.D. PIPING. (O.D. INCLUDES INSULATION WHERE REQUIRED)
DOMESTIC HOT WATERDOMESTIC HOT WATER
DOMESTIC HOT WATERDOMESTIC HOT WATER
1.25" HIGH LETTERS (MINIMUM)
12" LONGER SNAP-ON OR WRAP-AROUND
POLYESTER LABELS WITH ADHESIVE STRIP(S).
FLOW DIRECTION ARROW
.75" HIGH LETTERS (MINIMUM)
8" OR LONGER SNAP-ON OR WRAP-AROUND
POLYESTER LABELS WITH ADHESIVE STRIP(S).
FLOW…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .