Updated_Drawings_(Bid___Construction_Issue_January_29__2026)_0001.pdf
PDF 10 MB Posted
- Attached to
- REHAB PINE ISLAND HOUSING UNIT 120
- Solicitation number
- 140P5426R0006
About this file
This document is a set of construction bid and contract issue drawings for renovation work at Everglades National Park, specifically addressing three residential units (119, 120, and 124) in the Pine Island Community, located in Miami-Dade County, Florida. The project includes comprehensive demolition and rehabilitation of structures to provide modern and functional living space for park housing.
The scope of work encompasses demolition of interior and exterior components including aluminum-framed screen wall systems, concrete condensing unit pads, roof overhang soffits, kitchen and bathroom fixtures, flooring finishes, wall tile, window treatments, and various plumbing and HVAC systems. New work includes replacement of roof assemblies utilizing standing seam metal roofing systems with modified bitumen roofing, installation of new terrazzo flooring with concrete slab infill, replacement of wood roof deck planks, drywall ceiling finishes, interior partitions, closet systems with bi-fold doors, hurricane paneling systems, new plumbing fixtures with thermostatic mixing valves, new HVAC systems including indoor heat pump units and outdoor condensing units, new electrical service with 200-amp panelboards and updated lighting and receptacle circuits, and fire protection sprinkler systems. The drawings establish construction details, specifications, equipment schedules, material requirements, and installation standards across architectural, structural, plumbing, mechanical, electrical, and fire protection disciplines. Work is designed to comply with 2015 International Building Code and 2015 International Residential Code, with particular attention to hurricane protection, accessibility standards (ADA), and occupancy safety requirements. The project issue date is January 29, 2026.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Sol_140P5426R0006_Amd_0001.pdf | ||
| Questions___Answers_0001.pdf | ||
| Specifications.pdf | ||
| Drawings.pdf | ||
| Wage_Determination.pdf | ||
| Past_Performance_Questionnaire.pdf | ||
| Sol_140P5426R0006.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
COVER SHEET G001
NORTH
MONROE CO.
CARD SO
UND RO
ADENVIRONMENTAL
KEY WEST
TO 1
CENTER
FLORIDA
BAY
BAY
FLAMINGO
V.C.
SABLE
CAPE
WHITEWATER
OCEAN
V.C.
SOUND
BARNES
MCLAUGHLIN
KEY
MEXICO
GULF OF
OCHOPEE
NAPLES
TO
EVERGLADES
COAST
GULF
V.C.
CITY
FORT MYERS
BIG CYPRESS29
TO
RESERVATION
FL
O
R
ID
A' S
TU
R
N
PI
KE
MONROE COUNTY
HIDDEN LAKE
CENTER
BEARD
DANIEL
LOOP
D
AD
E C
O U
N
TY
M O
N R
O E
C O
U N
TY
ROAD
TAMIAMI
PALM
ROYAL
CENTER
HQ.
RESEARCH
CITY
MAIN
V.C.
FLORIDA
CITY
LEISURE
HOMESTEAD
CHEKIKA
VALLEY
SHARK
MUCCOSUKEE
PRESERVE
COLLIER COUNTY
TAMIAMI TRAIL
NATIONAL
INDIAN
ATLANTIC
LARGO
KEY
NATIONAL
DADE CO.
PARK
BISCAYNE
DRIVECANAL
FORT LAUDERDALE
MIAMI
TO
UNESCO
EVERGLADES NATIONAL PARK
WORLD HERITAGE SITE
PARK OFFICIAL FOR LIMITATIONS.
FEDERAL GOVERNMENT. CHECK WITH LOCAL
PARK HAVE BEEN ACQUIRED BY THE
BOUNDARY OF THE EVERGLADES NATIONAL
NOT ALL LANDS INSIDE THE AUTHORIZED
NOTE
SWAMP OR SLOUGH
PUBLIC AIRPORTS
OBSERVATION TOWER
INFORMATION CENTER
RANGER STATION
PARK HEADQUARTERS
VISITOR CENTER
HQ.
V.C.
CREEK
LEGEND
PARK BOUNDARY
COUNTY LINE
BASIC DATA: BOUNDARY MAPS 160/20,013B 9/89; 160/20,012 3/85; PARK MINI FOLDER 1992; REVISED & REDRAWN 5/93. UPDATED 11/98. SGS.
MEXICO
OF
GULF
LE
E
C O
ATLANTIC
FLORIDA BAY
EVERGLADES
PARK
NATIONAL
KEY LARGO
OCEAN
NORTH MIAMI BEACH
FORT LAUDERDALE
H
EN
D R
Y C
O
KENDALL
PALM BEACH CO.
DADE CO.
BROWARD CO.
FLORIDA CITY
HOMESTEAD
PRINSTON
C O
LL
IE
R C
O
MONROE CO.
PRESERVE
NATIONAL
BIG CYPRESS
MIAMI
NATIONAL
BISCAYNE
PARK
HOLLYWOOD
SCALE IN MILES
10 0 10 20SOUTHERN
FLORIDA
176672
SCALE IN MILES
SCALE IN KILOMETERS
5 0
15105
5 10 LOCATION WITHIN PARK
NAME OF PARK
TITLE OF SHEET
EVERGLADES NATIONAL PARK
PINE ISLAND COMMUNITY
STATEREGION COUNTY
SOUTHEAST FLORIDAMIAMI-DADE
PMIS / PKG. NO.
SHEET
DRAWING NO.
OF 34
DATE:
TECH. REVIEW:
DRAWN:
DESIGNED:REVISIONS SUB SHEET NO.
NATIONAL PARK SERVICE
DENVER SERVICE CENTER
DEPARTMENT OF THE INTERIOR
UNITED STATES
KS/EW
EW / CH
11/21/2022
KS / CH 305612
11/21/2022
BID & CONSTRUCTION ISSUE
JANUARY 29, 2026
11/21/2022
D101
1 DEMOLITION FLOOR PLAN
SCALE 1/4" = 1'
1/4" = 1' - 0" SCALE OF FEET
0'4' 4' 8'
GENERAL NOTES
KEY NOTES
D1 DEMOLISH ALUMINUM-FRAMED SCREENWALL SYSTEM
D2 DEMOLISH CONCRETE CONDENSING UNIT PAD
D3 DEMOLISH ROOF OVERHANG SOFFITS AND VENTS
D4 DEMOLISH CLOSET SLIDING DOORS AND TRACKS. SALVAGE DOORS FOR REUSE.
D5 DEMOLISH KITCHEN CABINETS
D6 DEMOLISH KITCHEN APPLIANCES
D7 DEMOLISH FLOOR TILE (UNIT 119 ONLY)
D8 DEMOLISH SINK VANITIES, WALL CABINETS, MIRRORS, TOWEL AND TOILET PAPER HOLDERS, SOAP TRAYS, ETC AND ALL
FASTENERS OR ANCHORS
D9 DEMOLISH WALL TILE AND SUBSTRATE AND/OR BACKERBOARD.
D10 EXISTING LIGHT SHELF TO REMAIN
D11 DEMOLISH EXISTING WATER-DAMAGED WOOD PLANK ROOF DECK, SHADED AREA INDICATES APPROXIMATE EXTENTS OF KNOWN
DAMAGE. ALL DETERIORATED OR WATER-DAMAGED DECK SHALL BE REMOVED, ADVISE CONTRACT OFFICER IF DAMAGE AREA IS
FOUND TO EXTEND BEYOND THE INDICATED EXTENTS.
D12 DEMOLISH WOOD SHELVING, BRACKETS, SUPPORTS, HOOKS, HANGERS, ANCHORS, ETC. INSIDE OF CLOSET. PATCH HOLES.
D13 SAWCUT AND DEMOLISH CONCRETE FLOOR SLAB FOR EXTENTS REQUIRED TO DEMOLISH EXISTING UNDERSLAB PIPING AND INSTALL NEW WORK. HATCHED AREA INDICATES APPROXIMATE EXTENTS. REFER TO NEW WORK DRAWINGS FOR PATCH AND
REPAIR SCOPE.
D14 DEMOLISH PLASTER AND/OR GYPSUM BOARD WALL FINISHES BOTH SIDES OF WALL AND AS REQUIRED TO DEMOLISH EXISTING
ELECTRICAL AND PLUMBING, AND INSTALL NEW WORK.
D15 DEMOLISH EXISTING WALL TO SLOPED CEILING
D16 DEMOLISH WALLCOVERING FROM FULL EXTENTS OF WALL
D17 REFINISH WOOD SHELVING, DOOR, AND OTHER COMPONENT IN HALLWAY CLOSET.
D18 DEMOLISH SURFACE-MOUNTED HOUSE NUMBERS. EXACT LOCATION MAY VARY AT EACH UNIT.
D19 DEMOLISH HOSE BRACKET
D20 DEMOLISH ANTENNA AND ASSOCIATED BRACKETS AND WIRING. PATCH AND REPAIR EXISTING FINISHES AS REQUIRED. REFER TO
ELECTRICAL FOR SCOPE OF SATELLITE DISH
D21 DEMOLISH CORRUGATED METAL PANEL HURRICANE SHUTTERS AND SUPPORTS AT TOP AND BOTTOM OF WALL. PATCH AND
REPAIR SUBSTRATES.
D22 DEMOLISH PLASTER AND/OR DRYWALL CEILING FINISH AS REQUIRED FOR NEW WORK
D23 REMOVE WALL MOUNTED FIRE EXTINGUISHER
A INTERIOR DOORS: DEMOLISH INTERIOR DOOR. INTERIOR DOOR FRAMES SHALL REMAIN.
B EXTERIOR DOORS: DEMOLISH EXTERIOR DOOR. GENERAL CONTRACTOR TO EVALUATE CONDITION OF FRAME AND ADVISE
CONTRACT OFFICER.
C INTERIOR FINISHES: PLASTER AND PLASTERBOARD WALL AND CEILING FINISHES SHALL BE CUT, TRENCHED, DEMOLISHED AS
REQUIRED TO COMPLETE THE WORK.
D FLOOR FINISHES: TERRAZZO FLOOR AND CONCRETE SLAB SUBSTRATE SHALL BE CUT, TRENCED, DEMOLISHED AS REQUIRED TO INSTALL NEW WORK. MINIMIZE FLOOR SLAB DEMOLITION. LOCATE UNDERSLAB PIPING AND OTHER UTILITIES BY NON-DESTRUCTIVE MEANS PRIOR TO BEGINNING DEMOLITION. SAWCUT TERRAZZO FINISH AND CONCRETE SLAB IN CLEAN
STRAIGHT AND ORTHOGONAL LINES.
E INTERIOR WOOD TRIM: BASE TRIM AND DOOR TRIM SHALL BE DEMOLISHED WHERE REQUIRED TO CARRY OUT NEW WORK.
SALVAGE TRIM FOR REUSE. PROVIDE NEW TRIM WHERE REUSE OF SALVAGED TRIM IS NOT POSSIBLE
F WINDOWS: EXTERIOR WINDOWS ARE NOT IN CONTRACT. PROTECT WINDOWS FROM DAMAGE DURING THE COURSE OF THE
NEW WORK
G ROOF: DEMOLISH ROOFING DOWN TO THE ROOF DECK. INSPECT ROOF DECK FOR WATER DAMAGE AND SUITABILITY FOR INSTALLATION OF NEW ROOF. SURVEY FLAT ROOF AREAS WITH TONGUE AND GROOVE WOOD PLANK DECK FOR WATER DAMAGE.
ADVISE CONTRACT OFFICER OF FINDINGS PRIOR TO CARRYING OUT ADDITIONAL DEMOLITION OR INSTALLING NEW WORK. ANY
DETERIORATED SUBSTRATE (PLYWOOD SHEATHING, BUILDING WRAP, ECT) IS TO BE REMOVED.
H WINDOWS SHADES/BLINDS: DEMOLISH LOUVRE BLINDS, VALENCES, HANGERS AND ALL BRACKETS AND ANCHORS AT EACH WINDOW IN EACH UNIT. PATCH AND REPAIR ANY DAMAGE MADE BY REMOVAL OF BRACKETS, ANCHORS, OR OTHER.
5' -3
8'-1"
'-7
2'-6"
1' -1
33'-0"
1' -5
6'
-5
8' -7
AREA OF FINISH DEMOLITION
(CEILING AND/OR FLOORS)
EXISTING CONSTRUCTION
TO REMAIN
EXISTING CONSTRUCTION
TO BE DEMOLISHED
DOOR TO BE DEMOLISHED
FRAME TO REMAIN
DOOR AND FRAME TO
REMAIN
D101 SCALE 14" = 1'
D101 SCALE 14" = 1'
A INTERIOR DOORS: DEMOLISH INTERIOR DOORS AND HARDWARE. INTERIOR DOOR FRAMES SHALL REMAIN.
B EXTERIOR DOORS: DEMOLISH DOORS AND HARDWARE; GENERAL CONTRACTOR TO EVAULATE CONDITION OF
FRAME AND ADVISE OWNER
C INTERIOR FINISHES: PLASTER AND PLASTERBOARD WALL AND CEILING FINISHES SHALL BE CUT, TRENCHED, DEMOLISHED AS REQUIRED TO INSTALL NEW WORK. MINIMIZE INTERIOR FINISH DEMOLITION, UTILIZE DEMOLISHED CEILING AREA IN CORRIDOR FOR ACCESS TO ATTIC SPACE. FINISH DEMOLITION SHALL BE CARRIED OUT BY MAKING CLEAN STRAIGHT CUTS IN FINISHES AND DEMOLISHING FINISHES WITHIN CUT AREAS. WALL AND CEILING FRAMING SHALL BE PRESERVED UN-DAMAGED. ALL DAMAGE RESULTING FROM DEMO WORK SHALL BE PATCHED AND
REPAIRED TO MATCH ADJACENT WALL FINISH AND TEXTURE.
D FLOOR FINISHES: TERRAZZO FLOOR AND CONCRETE SLAB SUBSTRATE SHALL BE CUT, TRENCED, DEMOLISHED AS REQUIRED TO INSTALL NEW WORK. MINIMIZE FLOOR SLAB DEMOLITION. LOCATE UNDERSLAB PIPING AND OTHER UTILITIES BY NON-DESTRUCTIVE MEANS PRIOR TO BEGINNING DEMOLITION. SAWCUT TERRAZZO FINISH AND
CONCRETE SLAB IN CLEAN STRAIGHT AND ORTHOGONAL LINES.
E INTERIOR WOOD TRIM: BASE TRIM AND DOOR TRIM SHALL BE DEMOLISHED ONLY WHERE REQUIRED TO CARRY OUT NEW WORK. SALVAGE TRIM FOR REUSE. PROVIDE NEW TRIM WHERE REUSE OF SALVAGED TRIM IS NOT
POSSIBLE
F WINDOWS: EXTERIOR WINDOWS ARE NOT IN CONTRACT. PROTECT WINDOWS FROM DAMAGE DURING THE
COURSE OF THE NEW WORK
G ROOF: DEMOLISH ROOFING DOWN TO THE ROOF DECK. INSPECT ROOF DECK FOR WATER DAMAGE AND SUITABILITY FOR INSTALLATION OF NEW ROOF. SURVEY FLAT ROOF AREAS WITH TONGUE AND GROOVE WOOD PLANK DECK FOR WATER DAMAGE BEYOND THE KNOWN DAMAGED AREAS INDICATED ON DRAWINGS. ADVISE CONTRACT OFFICER OF FINDINGS PRIOR TO CARRYING OUT ADDITIONAL DEMOLITION OR INSTALLING NEW WORK.
ANY DETERIORATED SUBSTRATE (PLYWOOD SHEATHING, BUILDING WRAP, ECT) IS TO BE REMOVED.
H WINDOWS SHADES/BLINDS: DEMOLISH LOUVRE BLINDS, VALENCES, HANGERS AND ALL BRACKETS AND ANCHORS AT EACH WINDOW IN EACH UNIT. PATCH AND REPAIR ANY DAMAGE MADE BY REMOVAL OF BRACKETS, ANCHORS, OR OTHER.
D1 DEMOLISH ALUMINUM-FRAMED SCREENWALL SYSTEM
D2 DEMOLISH CONCRETE CONDENSING UNIT PAD
D3 DEMOLISH ROOF OVERHANG SOFFITS AND VENTS
D4 DEMOLISH CLOSET SLIDING DOORS AND TRACKS
D5 DEMOLISH KITCHEN CABINETS
D6 DEMOLISH KITCHEN APPLIANCES
D7 DEMOLISH FLOOR TILE (UNIT 119 ONLY)
D8 DEMOLISH SINK VANITIES, WALL CABINETS, MIRRORS, TOWEL AND TOILET PAPER HOLDERS, SOAP TRAYS, ETC AND
ALL FASTENERS OR ANCHORS
D9 DEMOLISH WALL TILE AND SUBSTRATE AND/OR BACKERBOARD.
D10 EXISTING LIGHT SHELF TO REMAIN - REFER TO ELECTRICAL
D11 DEMOLISH EXISTING WATER-DAMAGED WOOD PLANK ROOF DECK, HATCHED AREA INDICATES APPROXIMATE
EXTENTS OF KNOWN DAMAGE. ALL DETERIORATED OR WATER-DAMAGED DECK SHALL BE REMOVED, ADVISE
CONTRACT OFFICER IF DAMAGE AREA IS FOUND TO EXTEND BEYOND THE INDICATED EXTENTS.
D12 DEMOLISH WOOD SHELVING, BRACKETS, SUPPORTS, HOOKS, HANGERS, ANCHORS, ETC. INSIDE OF CLOSET. PATCH
HOLES.
D13 SAWCUT AND DEMOLISH CONCRETE FLOOR SLAB FOR EXTENTS REQUIRED TO DEMOLISH EXISTING UNDERSLAB PIPING AND INSTALL NEW WORK. HATCHED AREA INDICATES APPROXIMATE EXTENTS. REFER TO NEW WORK
DRAWINGS FOR PATCH AND REPAIR SCOPE.
D14 DEMOLISH PLASTER AND/OR GYPSUM BOARD WALL FINISHES BOTH SIDES OF WALL AND AS REQUIRED TO
DEMOLISH EXISTING ELECTRICAL AND PLUMBING, AND INSTALL NEW WORK.
D15 DEMOLISH EXISTING WALL FROM 42" AFF TO SLOPED CEILING
D16 DEMOLISH WALLCOVERING FROM FULL EXTENTS OF WALL
D17 DEMOLISH CLOSET IN CORRIDOR AND BEDROOM A INCLUDING WOOD SHELVING, DOORS, AND OTHER
COMPONENTS.
D18 DEMOLISH SURFACE-MOUNTED HOUSE NUMBERS. EXACT LOCATION MAY VARY AT EACH UNIT.
D19 DEMOLISH HOSE BRACKET
D20 DEMOLISH ANTENNA AND ASSOCIATED BRACKETS AND WIRING. PATCH AND REPAIR EXISTING FINISHES AS
REQUIRED. REFER TO ELECTRICAL FOR SCOPE OF SATELLITE DISH
D21 DEMOLISH CORRUGATED METAL PANEL HURRICANE SHUTTERS AND SUPPORTS AT TOP AND BOTTOM OF WALL.
PATCH AND REPAIR SUBSTRATES.
D22 DEMOLISH PLASTER AND/OR DRYWALL CEILING FINISH FOR EXTENTS INDICATED.
D23 REMOVE WALL MOUNTED FIRE EXTINGUISHER
349*��)*241.8-�1&:3)7>�)4478 &3)�<&11�&9�:3.9� 11��431>
1/4" = 1' - 0" SCALE OF FEET
0'4' 4' 8'
1*G*3)
SCREENED
PORCH
D
D104 D104
D
4 G*3*7&1�349*8
0*>�349*8
11/21/2022
W
D
WH
A.H.U.
SCREENED
PORCH
LIVING
ROOM
CAR
PORT
KITCHEN
BATHROOM
POWDER
ROOM
BEDROOM
A
BEDROOM
B
BEDROOM
C
05a
CLOSET
04a
CLOSET
CORRIDOR
05b
CLOSET
03a
LAUNDRY
D1
D2
D4
D4
D5 D6
D7
D12 D21
D14
D13
D15
D16
D17
D8,D9
D104
D104
D104
D104
D102
1 DEMOLITION REFLECTED CEILING PLAN
SCALE 1/4" = 1'
24'-2"
2' -9
'-6
54'-0"
4' -6
16'-10"
2' -9
5'
-4
2'-10"
'-4
3'-0"
11'-8"
'-3
AREA OF FINISH DEMOLITION
(CEILING AND/OR FLOORS)
EXISTING CONSTRUCTION
TO REMAIN
EXISTING CONSTRUCTION
TO BE DEMOLISHED
DOOR TO BE DEMOLISHED
FRAME TO REMAIN
DOOR AND FRAME TO
REMAIN
D102 SCALE 14" = 1'
A INTERIOR DOORS: DEMO INTERIOR DOORS AND HARDWARE. INTERIOR DOOR FRAMES SHALL REMAIN.
B EXTERIOR DOORS: DEMOLISH EXTERIOR DOOR AND HARDWARE. GENERAL CONTRACTOR TO EVALUATE CONDITION
OF FRAME AND ADVISE CONTRACT OFFICER. REFER TO KEYNOTES FOR SCOPE OF SCREEN DOORS.
C INTERIOR FINISHES SHALL BE CUT, TRENCHED, DEMOLISHED AS REQUIRED TO INSTALL NEW WORK. MINIMIZE
INTERIOR FINISH DEMO, UTILIZE DEMOLISHED CEILING AREA IN CORRIDOR FOR ACCESS TO ATTIC SPACE. FINISH DEMO SHALL BE CARRIED OUT BY MAKING CLEAN STRAIGHT CUTS IN FINISHES AND DEMOLISHING FINISHES WITHIN CUT AREAS. WALL AND CEILING FRAMING SHALL BE PRESERVED UN-DAMAGED. ALL DAMAGE RESULTING FROM DEMO WORK SHALL BE PATCHED AND REPAIRED TO MATCH ADJACENT WALL FINISH AND TEXTURE.
D FLOOR FINISHES: TERRAZZO FLOOR AND CONCRETE SLAB SUBSTRATE SHALL BE CUT, TRENCED, DEMOLISHED AS REQUIRED TO INSTALL NEW WORK. MINIMIZE FLOOR SLAB DEMO. LOCATE UNDERSLAB PIPING AND OTHER UTILITIES BY NON-DESTRUCTIVE MEANS PRIOR TO BEGINNING DEMO. SAWCUT TERRAZZO FINISH AND CONCRETE
SLAB IN CLEAN STRAIGHT AND ORTHOGONAL LINES.
E INTERIOR WOOD TRIM: BASE TRIM AND DOOR TRIM SHALL BE DEMOLISHED ONLY WHERE REQUIRED TO CARRY OUT NEW WORK. SALVAGE TRIM FOR REUSE. PROVIDE NEW TRIM WHERE REUSE OF SALVAGED TRIM IS NOT
POSSIBLE (PROFILE TO MATCH EXISTING TRIM)
F WINDOWS: EXTERIOR WINDOWS NIC. PROTECT WINDOWS AND HURRICANE SHUTTERS FROM DAMAGE DURING
THE COURSE OF CONSTRUCTION.
G EXTERIOR WOOD SIDING: DEMO EXISTING WOOD SIDING AND FASTENERS IN ENTIRETY. REMOVE BUILDING PAPER OR BUILDING WRAP IF PRESENT. ADVISE CONTRACT OFFICER OF DETERIORATED SUBSTRATE AND AWAIT DIRECTION
ON REPLACEMENT MATERIALS AND METHODS.
H WINDOWS SHADES/BLINDS: DEMO LOUVRE BLINDS, VALENCES, HANGERS AND ALL BRACKETS AND ANCHORS AT EACH WINDOW AND SLIDING DOOR IN EACH UNIT. PATCH AND REPAIR ANY DAMAGE MADE BY REMOVAL OF
BRACKETS, ANCHORS, OR OTHER COMPONENTS TO MATCH ADJACENT EXISTING SURFACES.
D1 DEMOLISH ALUMINUM-FRAMED SCREENWALL SYSTEM
D2 DEMOLISH CONCRETE CONDENSING UNIT PAD
D3 DEMOLISH ROOF OVERHANG SOFFITS AND VENTS
D4 DEMOLISH CLOSET SLIDING DOORS AND TRACKS
D5 DEMOLISH KITCHEN CABINETS
D6 DEMOLISH KITCHEN APPLIANCES
D7 DEMOLISH FLOOR TILE (UNIT 119 ONLY)
D8 DEMOLISH SINK VANITIES, WALL CABINETS, MIRRORS, TOWEL AND TOILET PAPER HOLDERS, SOAP TRAYS, ETC AND
ALL FASTENERS OR ANCHORS
D9 DEMOLISH WALL TILE AND SUBSTRATE AND/OR BACKERBOARD.
D10 EXISTING LIGHT SHELF TO REMAIN - REFER TO ELECTRICAL
D11 DEMOLISH EXISTING WATER-DAMAGED WOOD PLANK ROOF DECK, HATCHED AREA INDICATES APPROXIMATE
EXTENTS OF KNOWN DAMAGE. ALL DETERIORATED OR WATER-DAMAGED DECK SHALL BE REMOVED, ADVISE
CONTRACT OFFICER IF DAMAGE AREA IS FOUND TO EXTEND BEYOND THE INDICATED EXTENTS.
D12 DEMOLISH WOOD SHELVING, BRACKETS, SUPPORTS, HOOKS, HANGERS, ANCHORS, ETC. INSIDE OF CLOSET. PATCH
HOLES.
D13 SAWCUT AND DEMOLISH CONCRETE FLOOR SLAB FOR EXTENTS REQUIRED TO DEMOLISH EXISTING UNDERSLAB PIPING AND INSTALL NEW WORK. HATCHED AREA INDICATES APPROXIMATE EXTENTS. REFER TO NEW WORK
DRAWINGS FOR PATCH AND REPAIR SCOPE.
D14 DEMOLISH PLASTER AND/OR GYPSUM BOARD WALL FINISHES BOTH SIDES OF WALL AND AS REQUIRED TO
DEMOLISH EXISTING ELECTRICAL AND PLUMBING, AND INSTALL NEW WORK.
D15 DEMOLISH EXISTING WALL FROM 42" AFF TO SLOPED CEILING
D16 DEMOLISH WALLCOVERING FROM FULL EXTENTS OF WALL
D17 DEMOLISH CLOSET IN CORRIDOR AND BEDROOM A INCLUDING WOOD SHELVING, DOORS, AND OTHER
COMPONENTS.
D18 DEMOLISH SURFACE-MOUNTED HOUSE NUMBERS. EXACT LOCATION MAY VARY AT EACH UNIT.
D19 DEMOLISH HOSE BRACKET
D20 DEMOLISH ANTENNA AND ASSOCIATED BRACKETS AND WIRING. PATCH AND REPAIR EXISTING FINISHES AS
REQUIRED. REFER TO ELECTRICAL FOR SCOPE OF SATELLITE DISH
D21 DEMOLISH CORRUGATED METAL PANEL HURRICANE SHUTTERS AND SUPPORTS AT TOP AND BOTTOM OF WALL.
PATCH AND REPAIR SUBSTRATES.
D22 DEMOLISH PLASTER AND/OR DRYWALL CEILING FINISH FOR EXTENTS INDICATED.
0*>�349*8
G*3*7&1�349*8
1/4" = 1' - 0" SCALE OF FEET
0'4' 4' 8'
1*G*3)
11/21/2022
RIDGE BEAM
CATHEDRAL
CEILING
SCREENED
PORCH
LIVING
ROOM
CAR
PORT
KITCHEN
BATHROOM
POWDER
ROOM
BEDROOM
A
BEDROOM
B
BEDROOM
C
0505a
CLOSET
04a
CLOSET
CORRIDOR
05b
CLOSET
03a
LAUNDRY
54'-0" +/- (V.I.F.)
'-6
(V .I.
F.
D3
D3
D22
D11
D10
D10
21'-5" +/- (V.I.F.)
40'-0" +/- (V.I.F.)
'-1
0"
(V
.I.
F.
'-1
0"
(V
.I.
F.
2' -7
(V .I.
F.
'-3
(V .I.
F.
GENERAL NOTES
KEY NOTES
D1 DEMOLISH ALUMINUM-FRAMED SCREENWALL SYSTEM
D2 DEMOLISH CONCRETE CONDENSING UNIT PAD
D3 DEMOLISH ROOF OVERHANG SOFFITS AND VENTS
D4
D5 DEMOLISH KITCHEN CABINETS
D6 DEMOLISH KITCHEN APPLIANCES
D7 DEMOLISH FLOOR TILE (UNIT 119 ONLY)
D8 DEMOLISH SINK VANITIES, WALL CABINETS, MIRRORS, TOWEL AND TOILET PAPER HOLDERS, SOAP TRAYS, ETC AND ALL
FASTENERS OR ANCHORS
D9 DEMOLISH WALL TILE AND SUBSTRATE AND/OR BACKERBOARD.
D10 EXISTING LIGHT SHELF TO REMAIN
D11 DEMOLISH EXISTING WATER-DAMAGED WOOD PLANK ROOF DECK, SHADED AREA INDICATES APPROXIMATE EXTENTS OF KNOWN
DAMAGE. ALL DETERIORATED OR WATER-DAMAGED DECK SHALL BE REMOVED, ADVISE CONTRACT OFFICER IF DAMAGE AREA IS
FOUND TO EXTEND BEYOND THE INDICATED EXTENTS.
D12 DEMOLISH WOOD SHELVING, BRACKETS, SUPPORTS, HOOKS, HANGERS, ANCHORS, ETC. INSIDE OF CLOSET. PATCH HOLES.
D13 SAWCUT AND DEMOLISH CONCRETE FLOOR SLAB FOR EXTENTS REQUIRED TO DEMOLISH EXISTING UNDERSLAB PIPING AND INSTALL NEW WORK. HATCHED AREA INDICATES APPROXIMATE EXTENTS. REFER TO NEW WORK DRAWINGS FOR PATCH AND
REPAIR SCOPE.
D14 DEMOLISH PLASTER AND/OR GYPSUM BOARD WALL FINISHES BOTH SIDES OF WALL AND AS REQUIRED TO DEMOLISH EXISTING
ELECTRICAL AND PLUMBING, AND INSTALL NEW WORK.
D15 DEMOLISH EXISTING WALL TO SLOPED CEILING
D16 DEMOLISH WALLCOVERING FROM FULL EXTENTS OF WALL
D17
D18 DEMOLISH SURFACE-MOUNTED HOUSE NUMBERS. EXACT LOCATION MAY VARY AT EACH UNIT.
D19 DEMOLISH HOSE BRACKET
D20 DEMOLISH ANTENNA AND ASSOCIATED BRACKETS AND WIRING. PATCH AND REPAIR EXISTING FINISHES AS REQUIRED. REFER TO
ELECTRICAL FOR SCOPE OF SATELLITE DISH
D21 DEMOLISH CORRUGATED METAL PANEL HURRICANE SHUTTERS AND SUPPORTS AT TOP AND BOTTOM OF WALL. PATCH AND
REPAIR SUBSTRATES.
D22 DEMOLISH PLASTER AND/OR DRYWALL CEILING FINISH AS REQUIRED FOR NEW WORK
D23 REMOVE WALL MOUNTED FIRE EXTINGUISHER
A INTERIOR DOORS: DEMOLISH INTERIOR DOOR. INTERIOR DOOR FRAMES SHALL REMAIN.
B EXTERIOR DOORS: DEMOLISH EXTERIOR DOOR. GENERAL CONTRACTOR TO EVALUATE CONDITION OF FRAME AND ADVISE
CONTRACT OFFICER.
C INTERIOR FINISHES: PLASTER AND PLASTERBOARD WALL AND CEILING FINISHES SHALL BE CUT, TRENCHED, DEMOLISHED AS
REQUIRED TO COMPLETE THE WORK.
D FLOOR FINISHES: TERRAZZO FLOOR AND CONCRETE SLAB SUBSTRATE SHALL BE CUT, TRENCED, DEMOLISHED AS REQUIRED TO INSTALL NEW WORK. MINIMIZE FLOOR SLAB DEMOLITION. LOCATE UNDERSLAB PIPING AND OTHER UTILITIES BY NON-DESTRUCTIVE MEANS PRIOR TO BEGINNING DEMOLITION. SAWCUT TERRAZZO FINISH AND CONCRETE SLAB IN CLEAN
STRAIGHT AND ORTHOGONAL LINES.
E INTERIOR WOOD TRIM: BASE TRIM AND DOOR TRIM SHALL BE DEMOLISHED WHERE REQUIRED TO CARRY OUT NEW WORK.
SALVAGE TRIM FOR REUSE. PROVIDE NEW TRIM WHERE REUSE OF SALVAGED TRIM IS NOT POSSIBLE
F WINDOWS: EXTERIOR WINDOWS ARE NOT IN CONTRACT. PROTECT WINDOWS FROM DAMAGE DURING THE COURSE OF THE
NEW WORK
G ROOF: DEMOLISH ROOFING DOWN TO THE ROOF DECK. INSPECT ROOF DECK FOR WATER DAMAGE AND SUITABILITY FOR INSTALLATION OF NEW ROOF. SURVEY FLAT ROOF AREAS WITH TONGUE AND GROOVE WOOD PLANK DECK FOR WATER DAMAGE.
ADVISE CONTRACT OFFICER OF FINDINGS PRIOR TO CARRYING OUT ADDITIONAL DEMOLITION OR INSTALLING NEW WORK. ANY
DETERIORATED SUBSTRATE (PLYWOOD SHEATHING, BUILDING WRAP, ECT) IS TO BE REMOVED.
H WINDOWS SHADES/BLINDS: DEMOLISH LOUVRE BLINDS, VALENCES, HANGERS AND ALL BRACKETS AND ANCHORS AT EACH WINDOW IN EACH UNIT. PATCH AND REPAIR ANY DAMAGE MADE BY REMOVAL OF BRACKETS, ANCHORS, OR OTHER.
DEMOLISH CLOSET SLIDING DOORS AND TRACKS. SALVAGE DOORS FOR REUSE.
REFINISH WOOD SHELVING, DOOR, AND OTHER COMPONENT IN HALLWAY CLOSET.
'-0
'-0
'-0
22'-10" 23'-7"
82'-6"
48'-6"
'-0
36'-1"
3' -0
'-0
3' -0
3'-0"
3'-0"
8' -0
9' -0
D103 SCALE 14" = 1'
A INTERIOR DOORS: DEMO INTERIOR DOORS AND HARDWARE. INTERIOR DOOR FRAMES SHALL REMAIN.
B EXTERIOR DOORS: DEMOLISH EXTERIOR DOOR AND HARDWARE. GENERAL CONTRACTOR TO EVALUATE CONDITION
OF FRAME AND ADVISE CONTRACT OFFICER. REFER TO KEYNOTES FOR SCOPE OF SCREEN DOORS.
C INTERIOR FINISHES SHALL BE CUT, TRENCHED, DEMOLISHED AS REQUIRED TO INSTALL NEW WORK. MINIMIZE
INTERIOR FINISH DEMO, UTILIZE DEMOLISHED CEILING AREA IN CORRIDOR FOR ACCESS TO ATTIC SPACE. FINISH DEMO SHALL BE CARRIED OUT BY MAKING CLEAN STRAIGHT CUTS IN FINISHES AND DEMOLISHING FINISHES WITHIN CUT AREAS. WALL AND CEILING FRAMING SHALL BE PRESERVED UN-DAMAGED. ALL DAMAGE RESULTING FROM DEMO WORK SHALL BE PATCHED AND REPAIRED TO MATCH ADJACENT WALL FINISH AND TEXTURE.
D FLOOR FINISHES: TERRAZZO FLOOR AND CONCRETE SLAB SUBSTRATE SHALL BE CUT, TRENCED, DEMOLISHED AS REQUIRED TO INSTALL NEW WORK. MINIMIZE FLOOR SLAB DEMO. LOCATE UNDERSLAB PIPING AND OTHER UTILITIES BY NON-DESTRUCTIVE MEANS PRIOR TO BEGINNING DEMO. SAWCUT TERRAZZO FINISH AND CONCRETE
SLAB IN CLEAN STRAIGHT AND ORTHOGONAL LINES.
E INTERIOR WOOD TRIM: BASE TRIM AND DOOR TRIM SHALL BE DEMOLISHED ONLY WHERE REQUIRED TO CARRY OUT NEW WORK. SALVAGE TRIM FOR REUSE. PROVIDE NEW TRIM WHERE REUSE OF SALVAGED TRIM IS NOT
POSSIBLE (PROFILE TO MATCH EXISTING TRIM)
F WINDOWS: EXTERIOR WINDOWS NIC. PROTECT WINDOWS AND HURRICANE SHUTTERS FROM DAMAGE DURING
THE COURSE OF CONSTRUCTION.
G EXTERIOR WOOD SIDING: DEMO EXISTING WOOD SIDING AND FASTENERS IN ENTIRETY. REMOVE BUILDING PAPER OR BUILDING WRAP IF PRESENT. ADVISE CONTRACT OFFICER OF DETERIORATED SUBSTRATE AND AWAIT DIRECTION
ON REPLACEMENT MATERIALS AND METHODS.
H WINDOWS SHADES/BLINDS: DEMO LOUVRE BLINDS, VALENCES, HANGERS AND ALL BRACKETS AND ANCHORS AT EACH WINDOW AND SLIDING DOOR IN EACH UNIT. PATCH AND REPAIR ANY DAMAGE MADE BY REMOVAL OF
BRACKETS, ANCHORS, OR OTHER COMPONENTS TO MATCH ADJACENT EXISTING SURFACES.
DR01 DEMOLISH ASPHALT ROLL-ROOFING, UNDERLAYMENT, EDGE TRIMS, FASCIAS AND DRIP EDGES. DETERIORATED SUBSTRATES OR SHEATHING SHALL BE REMOVED AND REPLACED. ADVISE CONTRACT OFFICER OF DETERIORATED
MATERIALS AND AWAIT DIRECTION ON REPLACEMENT MATERIALS AND METHODS.
DR02
DEMOLISH ASPHALT ROLL ROOFING AND SUBSTRATE AT GABLE ENDS, UNIT #119 ONLY.
DR03 AT UNIT #119 DEMOLISH ASPHALT SHINGLE ROOFING FROM SLOPED ROOF AREA. DEMOLISH UNDERLAYMENT, EDGE TRIMS, FASCIAS AND DRIP EDGES. DETERIORATED SUBSTRATES OR SHEATHING SHALL BE REMOVED AND REPLACED. ADVISE CONTRACT OFFICER OF DETERIORATED MATERIALS AND AWAIT DIRECTION ON REPLACEMENT
MATERIALS AND METHODS.
DR04 AT UNITS #120 AND #124 DEMOLISH ASPHALT ROLL-ROOFING FROM LOW SLOPED ROOF AREA. DEMOLISH UNDERLAYMENT, EDGE TRIMS, FASCIAS AND DRIP EDGES. DETERIORATED SUBSTRATES OR SHEATHING SHALL BE REMOVED AND REPLACED. ADVISE CONTRACT OFFICER OF DETERIORATED MATERIALS AND AWAIT DIRECTION
ON REPLACEMENT MATERIALS AND METHODS.
DR05 REMOVE AND SALVAGE EXISTING ROOF VENTILATORS FOR RE-INSTALLATION
DR06 DEMOLISH ROOF AND STACK VENTS
SL
O
PE
SL
O
PE
G*3*7&1�349*8
1/4" = 1' - 0" SCALE OF FEET
0'4' 4' 8'
0*>�349*8
D102 SCALE 18" = 1'
D102 SCALE 18" = 1'
D102 SCALE 18" = 1'
D102 SCALE 18" = 1'
A INTERIOR DOORS: DEMO INTERIOR DOORS AND HARDWARE. INTERIOR DOOR FRAMES SHALL REMAIN.
B EXTERIOR DOORS: DEMOLISH EXTERIOR DOOR AND HARDWARE. GENERAL CONTRACTOR TO EVALUATE CONDITION
OF FRAME AND ADVISE CONTRACT OFFICER. REFER TO KEYNOTES FOR SCOPE OF SCREEN DOORS.
C INTERIOR FINISHES SHALL BE CUT, TRENCHED, DEMOLISHED AS REQUIRED TO INSTALL NEW WORK. MINIMIZE
INTERIOR FINISH DEMO, UTILIZE DEMOLISHED CEILING AREA IN CORRIDOR FOR ACCESS TO ATTIC SPACE. FINISH DEMO SHALL BE CARRIED OUT BY MAKING CLEAN STRAIGHT CUTS IN FINISHES AND DEMOLISHING FINISHES WITHIN CUT AREAS. WALL AND CEILING FRAMING SHALL BE PRESERVED UN-DAMAGED. ALL DAMAGE RESULTING FROM DEMO WORK SHALL BE PATCHED AND REPAIRED TO MATCH ADJACENT WALL FINISH AND TEXTURE.
D FLOOR FINISHES: TERRAZZO FLOOR AND CONCRETE SLAB SUBSTRATE SHALL BE CUT, TRENCED, DEMOLISHED AS REQUIRED TO INSTALL NEW WORK. MINIMIZE FLOOR SLAB DEMO. LOCATE UNDERSLAB PIPING AND OTHER UTILITIES BY NON-DESTRUCTIVE MEANS PRIOR TO BEGINNING DEMO. SAWCUT TERRAZZO FINISH AND CONCRETE
SLAB IN CLEAN STRAIGHT AND ORTHOGONAL LINES.
E INTERIOR WOOD TRIM: BASE TRIM AND DOOR TRIM SHALL BE DEMOLISHED ONLY WHERE REQUIRED TO CARRY OUT NEW WORK. SALVAGE TRIM FOR REUSE. PROVIDE NEW TRIM WHERE REUSE OF SALVAGED TRIM IS NOT
POSSIBLE (PROFILE TO MATCH EXISTING TRIM)
F WINDOWS: EXTERIOR WINDOWS NIC. PROTECT WINDOWS AND HURRICANE SHUTTERS FROM DAMAGE DURING
THE COURSE OF CONSTRUCTION.
G EXTERIOR WOOD SIDING: DEMO EXISTING WOOD SIDING AND FASTENERS IN ENTIRETY. REMOVE BUILDING PAPER OR BUILDING WRAP IF PRESENT. ADVISE CONTRACT OFFICER OF DETERIORATED SUBSTRATE AND AWAIT DIRECTION
ON REPLACEMENT MATERIALS AND METHODS.
H WINDOWS SHADES/BLINDS: DEMO LOUVRE BLINDS, VALENCES, HANGERS AND ALL BRACKETS AND ANCHORS AT EACH WINDOW AND SLIDING DOOR IN EACH UNIT. PATCH AND REPAIR ANY DAMAGE MADE BY REMOVAL OF
BRACKETS, ANCHORS, OR OTHER COMPONENTS TO MATCH ADJACENT EXISTING SURFACES.
D1 DEMOLISH ALUMINUM-FRAMED SCREENWALL SYSTEM
D2 DEMOLISH CONCRETE CONDENSING UNIT PAD
D3 DEMOLISH ROOF OVERHANG SOFFITS AND VENTS
D4 DEMOLISH CLOSET SLIDING DOORS AND TRACKS
D5 DEMOLISH KITCHEN CABINETS
D6 DEMOLISH KITCHEN APPLIANCES
D7 DEMOLISH FLOOR TILE (UNIT 119 ONLY)
D8 DEMOLISH SINK VANITIES, WALL CABINETS, MIRRORS, TOWEL AND TOILET PAPER HOLDERS, SOAP TRAYS, ETC AND
ALL FASTENERS OR ANCHORS
D9 DEMOLISH WALL TILE AND SUBSTRATE AND/OR BACKERBOARD.
D10 EXISTING LIGHT SHELF TO REMAIN - REFER TO ELECTRICAL
D11 DEMOLISH EXISTING WATER-DAMAGED WOOD PLANK ROOF DECK, HATCHED AREA INDICATES APPROXIMATE
EXTENTS OF KNOWN DAMAGE. ALL DETERIORATED OR WATER-DAMAGED DECK SHALL BE REMOVED, ADVISE
CONTRACT OFFICER IF DAMAGE AREA IS FOUND TO EXTEND BEYOND THE INDICATED EXTENTS.
D12 DEMOLISH WOOD SHELVING, BRACKETS, SUPPORTS, HOOKS, HANGERS, ANCHORS, ETC. INSIDE OF CLOSET. PATCH
HOLES.
D13 SAWCUT AND DEMOLISH CONCRETE FLOOR SLAB FOR EXTENTS REQUIRED TO DEMOLISH EXISTING UNDERSLAB PIPING AND INSTALL NEW WORK. HATCHED AREA INDICATES APPROXIMATE EXTENTS. REFER TO NEW WORK
DRAWINGS FOR PATCH AND REPAIR SCOPE.
D14 DEMOLISH PLASTER AND/OR GYPSUM BOARD WALL FINISHES BOTH SIDES OF WALL AND AS REQUIRED TO
DEMOLISH EXISTING ELECTRICAL AND PLUMBING, AND INSTALL NEW WORK.
D15 DEMOLISH EXISTING WALL FROM 42" AFF TO SLOPED CEILING
D16 DEMOLISH WALLCOVERING FROM FULL EXTENTS OF WALL
D17 DEMOLISH CLOSET IN CORRIDOR AND BEDROOM A INCLUDING WOOD SHELVING, DOORS, AND OTHER
COMPONENTS.
D18 DEMOLISH SURFACE-MOUNTED HOUSE NUMBERS. EXACT LOCATION MAY VARY AT EACH UNIT.
D19 DEMOLISH HOSE BRACKET
D20 DEMOLISH ANTENNA AND ASSOCIATED BRACKETS AND WIRING. PATCH AND REPAIR EXISTING FINISHES AS
REQUIRED. REFER TO ELECTRICAL FOR SCOPE OF SATELLITE DISH
D21 DEMOLISH CORRUGATED METAL PANEL HURRICANE SHUTTERS AND SUPPORTS AT TOP AND BOTTOM OF WALL.
PATCH AND REPAIR SUBSTRATES.
D22 DEMOLISH PLASTER AND/OR DRYWALL CEILING FINISH FOR EXTENTS INDICATED.
1/4" = 1' - 0" SCALE OF FEET
0'4' 4' 8'
0*>�349*8
G*3*7&1�349*8
OPEN
TO
BEYOND
OPEN
TO
BEYOND
A101
1 FLOOR PLAN
SLAB REPAIR AND INFILL DETAIL
A101
2 CONCRETE HVAC PAD DETAIL
A101
SCALE: B
KEY NOTES
GENERAL NOTES
SCALE: B
SCALE: A
WINDOW SHADE SCHEDULE
A PROTECT ALL EXISTING FINISHES FROM DAMAGE DURING THE COURSE OF THE WORK.
PROVIDE PROTECTIVE FLOOR COVERINGS FOR FULL EXTENT OF INTERIOR FINISH FLOORS.
PROTECT CABINETS, APPLIANCES, FIXTURES AND OTHER EXISTING-TO-REMAIN ITEMS
WITH PLASTIC OR OTHER PROTECTIVE MEANS.
B INTERIOR PAINTING SCOPE:- EXISTING PAINTED INTERIOR SURFACES SHALL BE PAINTED.
INCLUDING BUT NOT LIMITED TO WALLS, CEILINGS, TRIM, DOORS, CLOSET INTERIORS
AND CLOSET DOORS, AND EXPOSED WOOD ROOF DECK PLANKS.- PREPARE ALL
SURFACES BY REMOVING EXISTING FASTENERS, ANCHORS OR OTHER ITEMS. FILL AND
PATCH ALL HOLES AND CRACKS. SCRAPE AND REMOVE FLAKING OR UNADHERED PAINT.-
REFER TO PAINTING SPECIFICATION FOR PAINT SYSTEMSPAINT COLOR SELECTIONS:-
PNT-1: CEILINGS- PNT-2: INTERIOR WALLS- PNT-3: CLOSETS AND SHELVING INTERIORS
AND TRIM
C DIMENSIONS PROVIDED ARE APPROXIMATE. ALL DIMENSIONS SHALL BE FIELD VERIFIED
BY CONTRACTOR.
D NEW INTERIOR PARTITION ASSEMBLY SHALL BE 2X4 WOOD FRAMING WITH 1/2"
DRYWALL EACH SIDE.
1 NEW CONCRETE PAD FOR CONDENSING UNIT. COORDINATE SIZE WITH MANUFACTURER
RECOMMENDATIONS
2 NEW VENTED FIBER CEMENT SOFFIT PANELS, DASHED LINE INDICATES EXTENT OF
VENTED PANELS.
3 NEW TERRAZZO FINISH ON NEW SLAB INFILL
4 PROVIDE HURRICANE PANELING SYSTEM MATCHING EXISTING DEMOLISHED SYSTEM.
REFER TO NOTES ON A301.
5 REPLACE WOOD ROOF DECK PLANKS WITH NEW PLANKS OF SAME DIMENSION
6 REPLACE EXISTING CLOSET DOORS, HARDWARE AND SLIDING TRACKS AT EACH CLOSET
AS REQUIRED. SALVAGE & REUSE EXISTING COMPONENTS AS POSSIBLE. ADD SHELF AND
POLE AT EACH CLOSET.
7 PATCH EXISTING WALL AS REQUIRED FOR INSTALLATION OF ELECTRICAL PANEL (REFER
TO ELECTRICAL)
8 WALL MOUNTED FIRE EXTINGUISHER -- REFER TO SPECIFICATIONS
9 REFER TO HARDWARE SET 10 IN SPECIFICATION SECTION 08 71 00 FOR CLOSET
HARDWARE
10 24x24 PLYWOOD ACCESS PANEL (PTD) IN DRYWALL CEILING - COORDINATE FINAL
LOCATION WITH WORK IN ATTIC - HEADERS TO MATCH BOTTOM CORD OF ROOF TRUSS -
1x3 WOOD TRIM (PTD) WITH 1/2" FOAM TAPE ALL SIDES
11 DRYWALL CEILING FINISH (PAINTED) MATCH EXISTING CEILING HEIGHT AND TIE INTO
EXISTING BULKHEAD IN LIVING ROOM (01)
12 DRYWALL CEILING FINISH (PAINTED) MATCH EXISTING CEILING SLOPE
WS-1 ROLLER WINDOW SHADE -- REFER TO SPECIFICATIONS
Pantry
HVAC
Closet
W
D
WH
A.H.U.
SCREENED
PORCH
LIVING
ROOM
CAR
PORT
KITCHEN
BATHROOM
POWDER
ROOM
BEDROOM
A
BEDROOM
B
BEDROOM
C
04a
CLOSET
CORRIDOR
03a
LAUNDRY
01a
05a
03d
04a
04b
04c
03c
03b
01b
03a
XX-XX 1
A401
XX-XX 4
0905b
XX-XX 4
SW-1
XX-XX 6
XX-XX 6
SAND, PATCH & APPLY EPOXY
COAT OVER SLAB IN COLOR TO
MATCH EXISTING @ PORCH
RESTORE EXIST TERRAZZO FLOORING
@ ALL LOC. U.O.N. REMOVE SEALER,
FINE GRIND, ADD GROUT AS NEEDED,
POLISH 200 GRIT AND APPLY NEW
REPLACE EXIST
SLABS IN-KIND @
ALL ENTRIES (TYP)
REBUILD CLOSET WALL TO
MEET 36" MIN REQ
CLEARANCE. RELOCATE
DOORS 01b AND 03c AS REQ
36" MIN
A201
A201
A201
A201
2' -9
NEW TERRAZZO FINISH
CONCRETE SLAB INFILL
0' -4
0'-4"
3" MIN. #57 STONE
4' x4' WELDED WIRE
MESH REINFORCING
AT MID-POINT OF SLAB
3" MIN. #57 STONE
0' -6
0' -4
HATCHED AREA INDICATES APPROXIMATE EXTENTS OF
NEW TERRAZZO FLOOR FINISH. COORDINATE WITH
EXTENTS OF REQUIRED SLAB DEMOLITION AND INFILL
HATCHED AREA INDICATES APPROXIMATE EXTENTS OF NEW
CEILING FINISH. COORDINATE WITH EXTENTS OF REQUIRED
CEILING DEMO.
A101
01a
05a
03d
04a
04b
04c
03c
03b
03a
SCALE: BA101 A101A101
A PROTECT ALL EXISTING FINISHES FROM DAMAGE DURING THE COURSE OF THE
WORK. PROVIDE PROTECTIVE FLOOR COVERINGS FOR FULL EXTENT OF
INTERIOR FINISH FLOORS. PROTECT CABINETS, APPLIANCES, FIXTURES AND
OTHER EXISTING-TO-REMAIN ITEMS WITH PLASTIC OR OTHER PROTECTIVE
MEANS.
B INTERIOR PAINTING SCOPE:
- EXISTING PAINTED INTERIOR SURFACES SHALL BE PAINTED. INCLUDING BUT
NOT LIMITED TO WALLS, CEILINGS, TRIM, DOORS, CLOSET INTERIORS AND
CLOSET DOORS, AND EXPOSED WOOD ROOF DECK PLANKS.
- PREPARE ALL SURFACES BY REMOVING EXISTING FASTENERS, ANCHORS OR
OTHER ITEMS. FILL AND PATCH ALL HOLES AND CRACKS. SCRAPE AND REMOVE
FLAKING OR UNADHERED PAINT.
- REFER TO PAINTING SPECIFICATION FOR PAINT SYSTEMS
PAINT COLOR SELECTIONS:
- PNT-1: CEILINGS
- PNT-2: INTERIOR WALLS
- PNT-3: CLOSETS AND SHELVING INTERIORS AND TRIM
C DIMENSIONS PROVIDED ARE APPROXIMATE. ALL DIMENSIONS SHALL BE FIELD
VERIFIED BY CONTRACTOR.
D NEW INTERIOR PARTITION ASSEMBLY SHALL BE 2X4 WOOD FRAMING WITH
1/2" DRYWALL EACH SIDE.
1 NEW CONCRETE PAD FOR CONDENSING UNIT. COORDINATE SIZE WITH
MANUFACTURER RECOMMENDATIONS
2 NEW VENTED FIBER CEMENT SOFFIT PANELS, DASHED LINE INDICATES EXTENT
OF VENTED PANELS.
3 NEW TERRAZZO FINISH ON NEW SLAB INFILL
4 PROVIDE HURRICANE PANELING SYSTEM MATCHING EXISTING DEMOLISHED
SYSTEM. REFER TO NOTES ON A301.
5 REPLACE WOOD ROOF DECK PLANKS WITH NEW PLANKS OF SAME DIMENSION
6 DEMOLISH AND REPLACE EXISTING IN-KIND CLOSET DOORS, HARDWARE AND
SLIDING TRACKS AT EACH CLOSET. REFER TO 2/A401 DETAILS FOR SCOPE AND
ARRANGEMENT.
7 PATCH EXISTING WALL AS REQUIRED FOR INSTALLATION OF ELECTRICAL PANEL
(REFER TO ELECTRICAL)
8 WALL MOUNTED FIRE EXTINGUISHER -- REFER TO SPECIFICATIONS
9 REFER TO HARDWARE SET 10 IN SPECIFICATION SECTION 08 71 00 FOR CLOSET
HARDWARE
2X4 STUD WALL,
FLOOR TO ROOF
DECK PT SILL PLATE,
LEAD BOTH SIDES
WITH FIBER CEMENT
PANEL CLADDING.
NOTE:
NEW WORK AT UNIT
#119 ONLY.
03a
LAUNDRY
PORCH
SCREENED
1/4" = 1' - 0" SCALE OF FEET
0'4' 4' 8'
1 1/2" = 1' - 0" SCALE OF FEET
0'1' 1'6"
0*>�349*8
G*3*7&1�349*8
1*G*3)
A2
A201 A201
A2
0905b
02a
02b
SCALE: BSCALE: A
SCALE: A
B
A
<.3)4<�8-&)*�8(-*):1*
WS-1 ROLLER WINDOW SHADE -- REFER TO SPECIFICATIONS
WS-2L
VERTICAL LOUVER BLINDS -- CONTROL ON RIGHT; DRAW/ STACK ONE
WAY, STACK LEFT; LENGTH TO BE WINDOW OPENING PLUS 1 1/2" --
REFER TO VERTICAL LOUVER BLIND SPECIFICATION
WS-2R
VERTICAL LOUVER BLINDS -- CONTROL ON LEFT; DRAW/ STACK ONE WAY,
STACK RIGHT; LENGTH TO BE WINDOW OPENING PLUS 1 1/2" -- REFER TO
VERTICAL LOUVER BLIND SPECIFICATION
11/21/2022
2' -9
NEW TERRAZZO FINISH
CONCRETE SLAB INFILL
0' -4
0'-4"
3" MIN. #57 STONE
4' x4' WELDED WIRE
MESH REINFORCING
AT MID-POINT OF SLAB
3" MIN. #57 STONE
0' -6
0' -4
HATCHED AREA INDICATES APPROXIMATE EXTENTS OF
NEW TERRAZZO FLOOR FINISH. COORDINATE WITH
EXTENTS OF REQUIRED SLAB DEMOLITION AND INFILL
HATCHED AREA INDICATES APPROXIMATE EXTENTS OF NEW
CEILING FINISH. COORDINATE WITH EXTENTS OF REQUIRED
CEILING DEMO.
A101
01a
05a
03d
04a
04b
04c
03c
03b
03a
SCALE: BA101 A101A101
A PROTECT ALL EXISTING FINISHES FROM DAMAGE DURING THE COURSE OF THE
WORK. PROVIDE PROTECTIVE FLOOR COVERINGS FOR FULL EXTENT OF
INTERIOR FINISH FLOORS. PROTECT CABINETS, APPLIANCES, FIXTURES AND
OTHER EXISTING-TO-REMAIN ITEMS WITH PLASTIC OR OTHER PROTECTIVE
MEANS.
B INTERIOR PAINTING SCOPE:
- EXISTING PAINTED INTERIOR SURFACES SHALL BE PAINTED. INCLUDING BUT
NOT LIMITED TO WALLS, CEILINGS, TRIM, DOORS, CLOSET INTERIORS AND
CLOSET DOORS, AND EXPOSED WOOD ROOF DECK PLANKS.
- PREPARE ALL SURFACES BY REMOVING EXISTING FASTENERS, ANCHORS OR
OTHER ITEMS. FILL AND PATCH ALL HOLES AND CRACKS. SCRAPE AND REMOVE
FLAKING OR UNADHERED PAINT.
- REFER TO PAINTING SPECIFICATION FOR PAINT SYSTEMS
PAINT COLOR SELECTIONS:
- PNT-1: CEILINGS
- PNT-2: INTERIOR WALLS
- PNT-3: CLOSETS AND SHELVING INTERIORS AND TRIM
C DIMENSIONS PROVIDED ARE APPROXIMATE. ALL DIMENSIONS SHALL BE FIELD
VERIFIED BY CONTRACTOR.
D NEW INTERIOR PARTITION ASSEMBLY SHALL BE 2X4 WOOD FRAMING WITH
1/2" DRYWALL EACH SIDE.
1 NEW CONCRETE PAD FOR CONDENSING UNIT. COORDINATE SIZE WITH
MANUFACTURER RECOMMENDATIONS
2 NEW VENTED FIBER CEMENT SOFFIT PANELS, DASHED LINE INDICATES EXTENT
OF VENTED PANELS.
3 NEW TERRAZZO FINISH ON NEW SLAB INFILL
4 PROVIDE HURRICANE PANELING SYSTEM MATCHING EXISTING DEMOLISHED
SYSTEM. REFER TO NOTES ON A301.
5 REPLACE WOOD ROOF DECK PLANKS WITH NEW PLANKS OF SAME DIMENSION
6 DEMOLISH AND REPLACE EXISTING IN-KIND CLOSET DOORS, HARDWARE AND
SLIDING TRACKS AT EACH CLOSET. REFER TO 2/A401 DETAILS FOR SCOPE AND
ARRANGEMENT.
7 PATCH EXISTING WALL AS REQUIRED FOR INSTALLATION OF ELECTRICAL PANEL
(REFER TO ELECTRICAL)
8 WALL MOUNTED FIRE EXTINGUISHER -- REFER TO SPECIFICATIONS
9 REFER TO HARDWARE SET 10 IN SPECIFICATION SECTION 08 71 00 FOR CLOSET
HARDWARE
2X4 STUD WALL,
FLOOR TO ROOF
DECK PT SILL PLATE,
LEAD BOTH SIDES
WITH FIBER CEMENT
PANEL CLADDING.
NOTE:
NEW WORK AT UNIT
#119 ONLY.
03a
LAUNDRY
PORCH
SCREENED
1/4" = 1' - 0" SCALE OF FEET
0'4' 4' 8'
1 1/2" = 1' - 0" SCALE OF FEET
0'1' 1'6"
0*>�349*8
G*3*7&1�349*8
1*G*3)
A2
A201 A201
A2
0905b
02a
02b
SCALE: BSCALE: A
SCALE: A
B
A
<.3)4<�8-&)*�8(-*):1*
WS-1 ROLLER WINDOW SHADE -- REFER TO SPECIFICATIONS
WS-2L
VERTICAL LOUVER BLINDS -- CONTROL ON RIGHT; DRAW/ STACK ONE
WAY, STACK LEFT; LENGTH TO BE WINDOW OPENING PLUS 1 1/2" --
REFER TO VERTICAL LOUVER BLIND SPECIFICATION
WS-2R
VERTICAL LOUVER BLINDS -- CONTROL ON LEFT; DRAW/ STACK ONE WAY,
STACK RIGHT; LENGTH TO BE WINDOW OPENING PLUS 1 1/2" -- REFER TO
VERTICAL LOUVER BLIND SPECIFICATION
11/21/2022
A111
A111
WS-1
WS-1
WS-1
W S-
W
S-
WS-1 WS-1WS-1 WS-1
WS-1 WS-1WS-1 WS-1 WS-1
A102
1 REFLECTED CEILING PLAN
SCALE 1/4" = 1'
RIDGE BEAM
CATHEDRAL
CEILING
SCREENED
PORCH
LIVING
ROOM
CAR
PORT
KITCHEN
BATHROOM
POWDER
ROOM
BEDROOM
A
BEDROOM
B
BEDROOM
C
0505a
CLOSET
04a
CLOSET
CORRIDOR
05b
CLOSET
03a
LAUNDRY
XX-XX 5
11'-6"
'-9
HATCHED AREA INDICATES APPROXIMATE EXTENTS OF
NEW TERRAZZO FLOOR FINISH. COORDINATE WITH
EXTENTS OF REQUIRED SLAB DEMOLITION AND INFILL
HATCHED AREA INDICATES APPROXIMATE EXTENTS OF NEW
CEILING FINISH. COORDINATE WITH EXTENTS OF REQUIRED
CEILING DEMO.
A102 SCALE 14" = 1'
A PROTECT ALL EXISTING FINISHES FROM DAMAGE DURING THE COURSE OF THE
WORK. PROVIDE PROTECTIVE FLOOR COVERINGS FOR FULL EXTENT OF
INTERIOR FINISH FLOORS. PROTECT CABINETS, APPLIANCES, FIXTURES AND
OTHER EXISTING-TO-REMAIN ITEMS WITH PLASTIC OR OTHER PROTECTIVE
MEANS.
B INTERIOR PAINTING SCOPE:
- EXISTING PAINTED INTERIOR SURFACES SHALL BE PAINTED. INCLUDING BUT
NOT LIMITED TO WALLS, CEILINGS, TRIM, DOORS, CLOSET INTERIORS AND
CLOSET DOORS, AND EXPOSED WOOD ROOF DECK PLANKS.
- PREPARE ALL SURFACES BY REMOVING EXISTING FASTENERS, ANCHORS OR
OTHER ITEMS. FILL AND PATCH ALL HOLES AND CRACKS. SCRAPE AND REMOVE
FLAKING OR UNADHERED PAINT.
- REFER TO PAINTING SPECIFICATION FOR PAINT SYSTEMS
PAINT COLOR SELECTIONS:
- PNT-1: CEILINGS
- PNT-2: INTERIOR WALLS
- PNT-3: CLOSETS AND SHELVING INTERIORS AND TRIM
C DIMENSIONS PROVIDED ARE APPROXIMATE. ALL DIMENSIONS SHALL BE FIELD
VERIFIED BY CONTRACTOR.
D NEW INTERIOR PARTITION ASSEMBLY SHALL BE 2X4 WOOD FRAMING WITH
1/2" DRYWALL EACH SIDE.
1 NEW CONCRETE PAD FOR CONDENSING UNIT. COORDINATE SIZE WITH
MANUFACTURER RECOMMENDATIONS
2 NEW VENTED FIBER CEMENT SOFFIT PANELS, DASHED LINE INDICATES EXTENT
OF VENTED PANELS.
3 NEW TERRAZZO FINISH ON NEW SLAB INFILL
4 PROVIDE NEW HURRICANE PANELING SYSTEM MATCHING EXISTING
DEMOLISHED SYSTEM. PROVIDE ALL REQUIRED COMPONENTS INCLUDING BUT
NOT LIMITED TO 0.050 THICK, 2" CORRUGATED ALUMINUM PANELS AND
POWDERCOATED ALUMINUM 2" 'H' HEADER TRACK AND STUDDED ANGLE
BOTTOM TRACK, AND ALL REQUIRED FASTENERS.
5 REPLACE WOOD ROOF DECK PLANKS WITH NEW PLANKS OF SAME DIMENSION
6 DEMOLISH AND REPLACE EXISTING IN-KIND CLOSET DOORS, HARDWARE AND
SLIDING TRACKS AT EACH CLOSET. REFER TO 2/A401 DETAILS FOR SCOPE AND
ARRANGEMENT.
7 PATCH EXISTING WALL AS REQUIRED FOR INSTALLATION OF ELECTRICAL PANEL
(REFER TO ELECTRICAL)
8 WALL MOUNTED FIRE EXTINGUISHER -- REFER TO SPECIFICATIONS
9 REFER TO HARDWARE SET 10 IN SPECIFICATION SECTION 08 71 00 FOR CLOSET
HARDWARE
10 24x24 PLYWOOD ACCESS PANEL (PTD) IN DRYWALL CEILING - COORDINATE
FINAL LOCATION WITH WORK IN ATTIC - HEADERS TO MATCH BOTTOM CORD
OF ROOF TRUSS - 1x3 WOOD TRIM (PTD) WITH 1/2" FOAM TAPE ALL SIDES
0*>�349*8
G*3*7&1�349*8
1/4" = 1' - 0" SCALE OF FEET
0'4' 4' 8'
1*G*3)
11/21/2022
KEY NOTES
GENERAL NOTES
A PROTECT ALL EXISTING FINISHES FROM DAMAGE DURING THE COURSE OF THE WORK.
PROVIDE PROTECTIVE FLOOR COVERINGS FOR FULL EXTENT OF INTERIOR FINISH FLOORS.
PROTECT CABINETS, APPLIANCES, FIXTURES AND OTHER EXISTING-TO-REMAIN ITEMS
WITH PLASTIC OR OTHER PROTECTIVE MEANS.
B INTERIOR PAINTING SCOPE:- EXISTING PAINTED INTERIOR SURFACES SHALL BE PAINTED.
INCLUDING BUT NOT LIMITED TO WALLS, CEILINGS, TRIM, DOORS, CLOSET INTERIORS
AND CLOSET DOORS, AND EXPOSED WOOD ROOF DECK PLANKS.- PREPARE ALL
SURFACES BY REMOVING EXISTING FASTENERS, ANCHORS OR OTHER ITEMS. FILL AND
PATCH ALL HOLES AND CRACKS. SCRAPE AND REMOVE FLAKING OR UNADHERED PAINT.-
REFER TO PAINTING SPECIFICATION FOR PAINT SYSTEMSPAINT COLOR SELECTIONS:-
PNT-1: CEILINGS- PNT-2: INTERIOR WALLS- PNT-3: CLOSETS AND SHELVING INTERIORS
AND TRIM
C DIMENSIONS PROVIDED ARE APPROXIMATE. ALL DIMENSIONS SHALL BE FIELD VERIFIED
BY CONTRACTOR.
D NEW INTERIOR PARTITION ASSEMBLY SHALL BE 2X4 WOOD FRAMING WITH 1/2"
DRYWALL EACH SIDE.
1 NEW CONCRETE PAD FOR CONDENSING UNIT. COORDINATE SIZE WITH MANUFACTURER
RECOMMENDATIONS
2 NEW VENTED FIBER CEMENT SOFFIT PANELS, DASHED LINE INDICATES EXTENT OF
VENTED PANELS.
3 NEW TERRAZZO FINISH ON NEW SLAB INFILL
4 PROVIDE HURRICANE PANELING SYSTEM MATCHING EXISTING DEMOLISHED SYSTEM.
REFER TO NOTES ON A301.
5 REPLACE WOOD ROOF DECK PLANKS WITH NEW PLANKS OF SAME DIMENSION
6 DEMOLISH AND REPLACE EXISTING ICLOSET DOORS, HARDWARE AND SLIDING TRACKS
AT EACH CLOSET. REPLACE WITH BI-FOLD DOORS AND ADD SHELF AND POLE AT EACH.
7 PATCH EXISTING WALL AS REQUIRED FOR INSTALLATION OF ELECTRICAL PANEL (REFER
TO ELECTRICAL)
8 WALL MOUNTED FIRE EXTINGUISHER -- REFER TO SPECIFICATIONS
9 REFER TO HARDWARE SET 10 IN SPECIFICATION SECTION 08 71 00 FOR CLOSET
HARDWARE
10 24x24 PLYWOOD ACCESS PANEL (PTD) IN DRYWALL CEILING - COORDINATE FINAL
LOCATION WITH WORK IN ATTIC - HEADERS TO MATCH BOTTOM CORD OF ROOF TRUSS -
1x3 WOOD TRIM (PTD) WITH 1/2" FOAM TAPE ALL SIDES
11 DRYWALL CEILING FINISH (PAINTED) MATCH EXISTING CEILING HEIGHT AND TIE INTO
EXISTING BULKHEAD IN LIVING ROOM (01)
12 DRYWALL CEILING FINISH (PAINTED) MATCH EXISTING CEILING SLOPE
A111
SLO
PE
SLO
PE
SLOPE
SLOPE
A111
SL
O
PE
SLOPE
SL
O
PE
RA-2
SLO
PE
SLO
PE
A111
A111
A111
A111
A111
A111
A111
A111
A111
A111
XX-XX 1
SLOPE
XX-XX
TYP.
XX-XX
TYP.
TYP.
RA-1
RA-1
1 ROOF PLAN
A103
2 ROOF ASSEMBLY 1
SCALE: B A103
3 ROOF ASSEMBLY 2
SCALE: B
A1
SCALE: A
SECONDARY ROOFING
UNDERLAYMENT
EXISTING ROOF RAFTER
EXISTING ROOF SHEATHING.
REPLACE DETERIORATED
SHEATHING AS REQ.
1" INSULATION BASE LAYER,
WITH 1/8" TAPERED
INSULATION OVERLAY
SBS MODIFIED BITUMEN
ROOFING SYSTEM
1/2" COVERBOARD
PRIMARY ROOFING
UNDERLAYMENT
STANDING SEAM METAL
ROOFING
SECONDARY ROOFING
UNDERLAYMENT
EXISTING ROOF RAFTER
EXISTING ROOF SHEATHING.
REPLACE DETERIORATED
SHEATHING AS REQ.
PRIMARY ROOFING
UNDERLAYMENT
RA-1 RA-2
1 ROOF VENTILATORS FLASHED INTO STANDING SEAM METAL ROOF -- CENTER IN STANDING
SEAM METAL PANELS -- PROVIDE DIVERTER STRIPS ABOVE VENTILATORS WHEN SPANNING
MULTIPLE PANELS
2 ROOF AND STACK VENTS FLASHED INTO STANDING SEAM METAL ROOF -- REFER TO
PLUMBING DRAWINGS
3 LOW PROFILE ROOF VENTS FLASHED INTO STANDING SEAM METAL ROOF -- CENTER IN
STANDING SEAM METAL PANELS -- REFER TO MECHANCIAL DRAWINGS
A DOCUMENT EXISTING CONDITION OF ROOF RAFTERS AND ROOF SHEATHING AFTER
DEMOLITION OF EXISTING ROOFING MATERIOALS AND PRIOR TO CARRYING OUT NEW
WORK. PROVIDE DOCUMENTATION OF EXISTING CONDITIONS TO CONTRACT OFFICER FOR
REVIEW AND CONFIRMATION OF NEW WORK DESIGN AND APPROACH.
B
ROOF ASSEMLBY RA-2 TO HAVE 1/8-INCH PER FOOT SLOPE WITH TAPERED INSULATION
ON TOP OF 1-INCH BASE LAYER
AREA OF TAPERED INSULATION
ROOF ASSEMBLY TYPE
STANDING SEAM METAL ROOFING
SYSTEM
STANDING SEAM
METAL ROOFING
ROOFING UNDERLAYMENT
32" APA RATED STRUCTURAL
1 SHEATHING
2X8 OVERBUILD
DRILL LINE OF 4" HOLES @ 2'-0"
O.C. FROM EAVE TO RIDGE IN
EACH RAFTER BAY TO PROVIDE
VENTILATION
EXISTING ROOF RAFTER
EXISTING ROOF SHEATHING
MATCH EXISTING SLOPE
NEW 2X8 RAFTER OVERBUILD.
ALIGNED WITH EXISTING RAFTER.
INSECT SCREEN
SBS MODIFIED BITUMEN
ROOFING SYSTEM
2" COVERBOARD
1" INSULATION BASE LAYER,
WITH 18" TAPERED
INSULATION OVERLAY
EXISTING WOOD
ROOF DECK
8" TO 12" SLOPE
SLO
PE
SLO
PE
SLOPE
SLOPE
1 ROOF OVERBUILD FOR FULL EXTENT OF RA-1. INSTALL NEW 2X8 RAFTERS OVER
EXSTING ROOF SHEATHING. ALIGN EACH NEW RAFTER W/EXISTING RAFTER
BELOW. FOR FULL EXTENT OF ROOF ASSEMBLY RA-1 INSTALL 2X8 RAFTER AND
SHEATHING OVERBUILD. TIE NEW RAFTERS TO EXISTING WITH GALVANIZED
METAL TIE PLATE. DRILL GRID OF 4" HOLES AT 2'-0" O.C. IN EXISTING ROOF
SHEATHING ACROSS ENTIRE ROOF AREA TO PROVIDE VENTILATION.
2 REINSTALL EXISTING ROOF VENTILATORS AND FLASHING INTO STANDING SEAM
METAL ROOF
3 ROOF AND STACK VENTS FLASHED INTO STANDING SEAM METAL ROOF -- REFER
TO PLUMBING DRAWINGS
4 LOW PROFILE ROOF VENTS FLASHED INTO STANDING SEAM METAL ROOF --
CENTER IN STANDING SEAM METAL PANELS -- REFER TO MECHANCIAL
DRAWINGS
SL
O
PE
SLOPE
SL
O
PE
SLO
PE
SLO
PE
A DOCUMENT EXISTING CONDITION OF ROOF RAFTERS AND ROOF SHEATHING
AFTER DEMOLITION OF EXISTING ROOFING MATERIOALS AND PRIOR TO
CARRYING OUT NEW WORK. PROVIDE DOCUMENTATION OF EXISTING
CONDITIONS TO CONTRACT OFFICER FOR REVIEW AND CONFIRMATION OF NEW
WORK DESIGN AND APPROACH.
B ROOF ASSEMLBY RA-2 TO HAVE 1/8-INCH PER FOOT SLOPE WITH TAPERED
INSULATION ON TOP OF 1-INCH BASE LAYER
SLOPE
0*>�349*8
G*3*7&1�349*8
1*G*3)
A103 SCALE: B A103 SCALE: B
1/4" = 1' - 0" SCALE OF FEET
0'4' 4' 8'
1 1/2" = 1' - 0" SCALE OF FEET
0'1' 1'6" B
A
A103 SCALE: A
A111
2 ROOF DETAIL - FLAT ROOF EDGE
A111
1 ROOF DETAIL - SLOPED ROOF EAVE
SCALE 1-1/2" = 1' SCALE 1-1/2" = 1'
A111
3 ROOF DETAIL
SCALE 1-1/2" = 1'
2" COVERBOARD
1" INSULATION
MODIFIED BITUMEN
ROOFING SYSTEM
PT WOOD BLOCKING
METAL DRIP EDGE
W/CLEAT
EXISTING ROOF
CONSTRUCTION
PT WOOD BLOCKING
FIBER CEMENT
FASCIA TRIM, 6", PAINTED.
VENTED FIBER CEMENT
SOFFIT PANEL, PAINTED
SECURE INSECT SCREEN
TO TOP SIDE OF SOFFIT
VENT CONTINUOUS
2" COVERBOARD
1" INSULATION
MODIFIED BITUMEN
ROOFING SYSTEM
PT WOOD BLOCKING
METAL DRIP EDGE
W/CLEAT
EXISTING ROOF
CONSTRUCTION
FIBER CEMENT FASCIA
TRIM, PAINTED
32" APA RATED STRUCTURAL
PLYWOOD SHEATHING
STANDING SEAM
METAL ROOF SYSTEM
METAL FLASHING TRIM
W/DRIP EDGE
MODIFIED BITUMEN
ROOFING SYSTEM
2" COVERBOARD
1" INSULATION
EXISTING ROOF DECK
ROOFING UNDERLAYMENT
2X8 RAFTER OVERBUILD, ALIGN
EACH NEW RAFTER W/EXISTING
ROOF RAFTER.
CUT STRIP IN EXISTING ROOF
SHEATHING. DRILL LINE OF 4"
HOLES AT 2'-0" O.C. FROM EAVE
TO RIDGE IN EACH RAFTER BAY
TO PROVIDE VENTILATION.
VENTED FIBER-CEMENT SOFFIT
PANEL. ENSURE CONTINUOUS
PATH OF AIRFLOW FROM SOFFIT
VENT TO RIDGE.
2X8, CONTINUOUS
TIE NEW AND EXISTING RAFTERS
TOGETHER WITH GALVANIZED
METAL SPLICE PLATE AT 4'-0" O.C.
INSECT SCREEN
STANDING SEAM METAL
ROOFING SYSTEM
METAL ROOF PANEL
SYSTEM GABLE-END TRIM
FIBER CEMENT FASCIA
TRIM, 8", PAINTED
ROOF UNDERLAYMENT
32" STRUCTURAL PLYWOOD
2X8 RAFTER OVERBUILD
PT WOOD SHIMS
FIBER CEMENT FASCIA
TRIM, 4", V.I.F
FIBER CEMENT VENTED
SOFFIT PANEL
TIE NEW AND EXISTING
RAFTERS TOGETHER WITH
GALVANIZED METAL SPLICE
PLATE AT 4'-0" O.C.
VENTED RIDGE CAP
STANDING SEAM
METAL ROOF SYSTEM
ROOFING UNDERLAYMENT
33" APA RATED STRUCTURAL 1
SHEATHING
NEW 2X8 RAFTER OVERBUILD,
ALIGNED WITH EXISTING RAFTER
EXISTING RAFTER AND
SHEATHING
TIE NEW AND EXISTING RAFTERS
TOGETHER WITH GALVANIZED
METAL SPLICE PLATE AT 4'-0" O.C.
1 1/2" = 1' - 0" SCALE OF FEET
0'1' 1'6"
11/21/2022
2" COVERBOARD
1" INSULATION
MODIFIED BITUMEN
ROOFING SYSTEM
PT WOOD BLOCKING
METAL DRIP EDGE
W/CLEAT
EXISTING ROOF
CONSTRUCTION
PT WOOD BLOCKING
FIBER CEMENT
FASCIA TRIM, 6", PAINTED.
VENTED FIBER CEMENT
SOFFIT PANEL, PAINTED
SECURE INSECT SCREEN
TO TOP SIDE OF SOFFIT
VENT CONTINUOUS
2" COVERBOARD
1" INSULATION
MODIFIED BITUMEN
ROOFING SYSTEM
PT WOOD BLOCKING
METAL DRIP EDGE
W/CLEAT
EXISTING ROOF
CONSTRUCTION
FIBER CEMENT FASCIA
TRIM, PAINTED
32" APA RATED STRUCTURAL
PLYWOOD SHEATHING
STANDING SEAM
METAL ROOF SYSTEM
METAL FLASHING TRIM
W/DRIP EDGE
MODIFIED BITUMEN
ROOFING SYSTEM
2" COVERBOARD
1" INSULATION
EXISTING ROOF DECK
ROOFING UNDERLAYMENT
2X8 RAFTER OVERBUILD, ALIGN
EACH NEW RAFTER W/EXISTING
ROOF RAFTER.
CUT STRIP IN EXISTING ROOF
SHEATHING. DRILL LINE OF 4"
HOLES AT 2'-0" O.C. FROM EAVE
TO RIDGE IN EACH RAFTER BAY
TO PROVIDE VENTILATION.
VENTED FIBER-CEMENT SOFFIT
PANEL. ENSURE CONTINUOUS
PATH OF AIRFLOW FROM SOFFIT
VENT TO RIDGE.
2X8, CONTINUOUS
TIE NEW AND EXISTING RAFTERS
TOGETHER WITH GALVANIZED
METAL SPLICE PLATE AT 4'-0" O.C.
INSECT SCREEN
STANDING SEAM METAL
ROOFING SYSTEM
METAL ROOF PANEL
SYSTEM GABLE-END TRIM
FIBER CEMENT FASCIA
TRIM, 8", PAINTED
ROOF UNDERLAYMENT
32" STRUCTURAL PLYWOOD
2X8 RAFTER OVERBUILD
PT WOOD SHIMS
FIBER CEMENT FASCIA
TRIM, 4", V.I.F
FIBER CEMENT VENTED
SOFFIT PANEL
TIE NEW AND EXISTING
RAFTERS TOGETHER WITH
GALVANIZED METAL SPLICE
PLATE AT 4'-0" O.C.
VENTED RIDGE CAP
STANDING SEAM
METAL ROOF SYSTEM
ROOFING UNDERLAYMENT
33" APA RATED STRUCTURAL 1
SHEATHING
NEW 2X8 RAFTER OVERBUILD,
ALIGNED WITH EXISTING RAFTER
EXISTING RAFTER AND
SHEATHING
TIE NEW AND EXISTING RAFTERS
TOGETHER WITH GALVANIZED
METAL SPLICE PLATE AT 4'-0" O.C.
1 1/2" = 1' - 0" SCALE OF FEET
0'1' 1'6"
11/21/2022
EXIST PLYWOOD,
REPLACE W/ 23/32" APA
RATED PLYWOOD AS REQ.
NEW ROOFING
UNDERLAYMENT TO
REPLACE EXISTING (GRN)
NEW STANDING SEAM
METAL ROOF SYSTEM
COUNTER FLASHING (GRN)
DRIP EDGE FLASHING (RED)
MODIFIED BITUMEN
ROOFING SYSTEM (BLUE)
1/2" COVER BD
PT WOOD BLOCKING
1" INSULATION TAPER
1/2:12 SLOPE TO EDGE
FIBER CEMENT FACIA
TRIM, PAINTED
EXIST STRUC
SHADED (V.I.F.)
0.5
METAL FLASHING (RED)
MODIFIED BITUMEN
ROOFING SYSTEM (BLUE)
24" BEYOND SLOPE
1/2" COVERBOARD
1" INSULATION TAPER
1/2:12 SLOPE TO EDGE
24"
CAULK SEALANT
SEALANT
2" COVERBOARD
1" INSULATION
MODIFIED BITUMEN
ROOFING SYSTEM
PT WOOD BLOCKING
METAL DRIP EDGE
W/CLEAT
EXISTING ROOF
CONSTRUCTION
PT WOOD BLOCKING
FIBER CEMENT
FASCIA TRIM, 6", PAINTED.
VENTED FIBER CEMENT
SOFFIT PANEL, PAINTED
SECURE INSECT SCREEN
TO TOP SIDE OF SOFFIT
VENT CONTINUOUS
2" COVERBOARD
1" INSULATION
MODIFIED BITUMEN
ROOFING SYSTEM
PT WOOD BLOCKING
METAL DRIP EDGE
W/CLEAT
EXISTING ROOF
CONSTRUCTION
FIBER CEMENT FASCIA
TRIM, PAINTED
32" APA RATED STRUCTURAL
PLYWOOD SHEATHING
STANDING SEAM
METAL ROOF SYSTEM
METAL FLASHING TRIM
W/DRIP EDGE
MODIFIED BITUMEN
ROOFING SYSTEM
2" COVERBOARD
1" INSULATION
EXISTING ROOF DECK
ROOFING UNDERLAYMENT
2X8 RAFTER OVERBUILD, ALIGN
EACH NEW RAFTER W/EXISTING
ROOF RAFTER.
CUT STRIP IN EXISTING ROOF
SHEATHING. DRILL LINE OF 4"
HOLES AT 2'-0" O.C. FROM EAVE
TO RIDGE IN EACH RAFTER BAY
TO PROVIDE VENTILATION.
VENTED FIBER-CEMENT SOFFIT
PANEL. ENSURE CONTINUOUS
PATH OF AIRFLOW FROM SOFFIT
VENT TO RIDGE.
2X8, CONTINUOUS
TIE NEW AND EXISTING RAFTERS
TOGETHER WITH GALVANIZED
METAL SPLICE PLATE AT 4'-0" O.C.
INSECT SCREEN
STANDING SEAM METAL
ROOFING SYSTEM
METAL ROOF PANEL
SYSTEM GABLE-END TRIM
FIBER CEMENT FASCIA
TRIM, 8", PAINTED
ROOF UNDERLAYMENT
32" STRUCTURAL PLYWOOD
2X8 RAFTER OVERBUILD
PT WOOD SHIMS
FIBER CEMENT FASCIA
TRIM, 4", V.I.F
FIBER CEMENT VENTED
SOFFIT PANEL
TIE NEW AND EXISTING
RAFTERS TOGETHER WITH
GALVANIZED METAL SPLICE
PLATE AT 4'-0" O.C.
VENTED RIDGE CAP
STANDING SEAM
METAL ROOF SYSTEM
ROOFING UNDERLAYMENT
33" APA RATED STRUCTURAL 1
SHEATHING
NEW 2X8 RAFTER OVERBUILD,
ALIGNED WITH EXISTING RAFTER
EXISTING RAFTER AND
SHEATHING
TIE NEW AND EXISTING RAFTERS
TOGETHER WITH GALVANIZED
METAL SPLICE PLATE AT 4'-0" O.C.
1 1/2" = 1' - 0" SCALE OF FEET
0'1' 1'6"
11/21/2022
2" COVERBOARD
1" INSULATION
MODIFIED BITUMEN
ROOFING SYSTEM
PT WOOD BLOCKING
METAL DRIP EDGE
W/CLEAT
EXISTING ROOF
CONSTRUCTION
PT WOOD BLOCKING
FIBER CEMENT
FASCIA TRIM, 6", PAINTED.
VENTED FIBER CEMENT
SOFFIT PANEL, PAINTED
SECURE INSECT SCREEN
TO TOP SIDE OF SOFFIT
VENT CONTINUOUS
2" COVERBOARD
1" INSULATION
MODIFIED BITUMEN
ROOFING SYSTEM
PT WOOD BLOCKING
METAL DRIP EDGE
W/CLEAT
EXISTING ROOF
CONSTRUCTION
FIBER CEMENT FASCIA
TRIM, PAINTED
32" APA RATED STRUCTURAL
PLYWOOD SHEATHING
STANDING SEAM
METAL ROOF SYSTEM
METAL FLASHING TRIM
W/DRIP EDGE
MODIFIED BITUMEN
ROOFING SYSTEM
2" COVERBOARD
1" INSULATION
EXISTING ROOF DECK
ROOFING UNDERLAYMENT
2X8 RAFTER OVERBUILD, ALIGN
EACH NEW RAFTER W/EXISTING
ROOF RAFTER.
CUT STRIP IN EXISTING ROOF
SHEATHING. DRILL LINE OF 4"
HOLES AT 2'-0" O.C. FROM EAVE
TO RIDGE IN EACH RAFTER BAY
TO PROVIDE VENTILATION.
VENTED FIBER-CEMENT SOFFIT
PANEL. ENSURE CONTINUOUS
PATH OF AIRFLOW FROM SOFFIT
VENT TO RIDGE.
2X8, CONTINUOUS
TIE NEW AND EXISTING RAFTERS
TOGETHER WITH GALVANIZED
METAL SPLICE PLATE AT 4'-0" O.C.
INSECT SCREEN
STANDING SEAM METAL
ROOFING SYSTEM
METAL ROOF PANEL
SYSTEM GABLE-END TRIM
FIBER CEMENT FASCIA
TRIM, 8", PAINTED
ROOF UNDERLAYMENT
32" STRUCTURAL PLYWOOD
2X8 RAFTER OVERBUILD
PT WOOD SHIMS
FIBER CEMENT FASCIA
TRIM, 4", V.I.F
FIBER CEMENT VENTED
SOFFIT PANEL
TIE NEW AND EXISTING
RAFTERS TOGETHER WITH
GALVANIZED METAL SPLICE
PLATE AT 4'-0" O.C.
VENTED RIDGE CAP
STANDING SEAM
METAL ROOF SYSTEM
ROOFING UNDERLAYMENT
33" APA RATED STRUCTURAL 1
SHEATHING
NEW 2X8 RAFTER OVERBUILD,
ALIGNED WITH EXISTING RAFTER
EXISTING RAFTER AND
SHEATHING
TIE NEW AND EXISTING RAFTERS
TOGETHER WITH GALVANIZED
METAL SPLICE PLATE AT 4'-0" O.C.
1 1/2" = 1' - 0" SCALE OF FEET
0'1' 1'6"
11/21/2022
BEDROOMBEDROOM
HALL
REMOVE EXIST HVAC CHASE &
REFRAME HALLWAY TO HEIGHT
OF TRUSSES.
CLOSE EXIST
OPENINGS ABOVE
DOORS.
5" (R30) CLOSED CELL SPRAY
INSULATION @ UNDERSIDE OF
EXISTING ROOF DECK (TYP)
DUCTWORK, ELECTRICAL, &
SPRINKLER PIPES IN ATTIC
3" (R19) CLOSED CELL SPRAY
INSULATION @ EXTERIOR
WALLS (TYP)
NOTE: PROVIDE SOUND
BATT INSULATION @
BATHROOM WALLS
NOTE: INSTALL CLOSED CELL
INSULATION PRIOR TO ANY
SPRINKLER PIPE INSTALLATION.
PROTECT SPRINKLER PIPES FROM
CONTACT W/ INSULATION.
A111
4 BUILDING SECTION
SCALE 1/2" = 1'
LIVING ROOM
REMOVE EXIST COVE
LIGHTING & CLOSE
OPENING @ CEILING
5" (R30) CLOSED CELL SPRAY
INSULATION @ UNDERSIDE OF
EXISTING ROOF DECK (TYP)
EXIST CATH
CEILING
EXIST
COVE
NOTE: SIMILAR DETAIL @
COVE ON KITCHEN SIDE.
A111
5 BUILDING SECTION AT LIVING ROOM
SCALE 1/2" = 1'
A EXTERIOR PAINTING SCOPE:
▪ ALL EXISTING PAINTED EXTERIOR SURFACES SHALL BE PREPARED AND PAINTED
INCLUDING BUT NOT LIMITED TO CLADDING PANELS, WINDOW TRIM, DOOR
FRAMES, SOFFITS, ROOF OVERHANGS AND ROOF DECKS.
▪ PREPARE ALL SURFACES BY REMOVING EXISTING UNUSED…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .