Updated_Drawings_(Bid___Construction_Issue_January_29__2026)_0001.pdf

PDF 10 MB Posted

Attached to
REHAB PINE ISLAND HOUSING UNIT 120
Solicitation number
140P5426R0006
Issued by

About this file

This document is a set of construction bid and contract issue drawings for renovation work at Everglades National Park, specifically addressing three residential units (119, 120, and 124) in the Pine Island Community, located in Miami-Dade County, Florida. The project includes comprehensive demolition and rehabilitation of structures to provide modern and functional living space for park housing.

The scope of work encompasses demolition of interior and exterior components including aluminum-framed screen wall systems, concrete condensing unit pads, roof overhang soffits, kitchen and bathroom fixtures, flooring finishes, wall tile, window treatments, and various plumbing and HVAC systems. New work includes replacement of roof assemblies utilizing standing seam metal roofing systems with modified bitumen roofing, installation of new terrazzo flooring with concrete slab infill, replacement of wood roof deck planks, drywall ceiling finishes, interior partitions, closet systems with bi-fold doors, hurricane paneling systems, new plumbing fixtures with thermostatic mixing valves, new HVAC systems including indoor heat pump units and outdoor condensing units, new electrical service with 200-amp panelboards and updated lighting and receptacle circuits, and fire protection sprinkler systems. The drawings establish construction details, specifications, equipment schedules, material requirements, and installation standards across architectural, structural, plumbing, mechanical, electrical, and fire protection disciplines. Work is designed to comply with 2015 International Building Code and 2015 International Residential Code, with particular attention to hurricane protection, accessibility standards (ADA), and occupancy safety requirements. The project issue date is January 29, 2026.

View the file

Other files

File Type Posted
Sol_140P5426R0006_Amd_0001.pdf PDF
Questions___Answers_0001.pdf PDF
Specifications.pdf PDF
Drawings.pdf PDF
Wage_Determination.pdf PDF
Past_Performance_Questionnaire.pdf PDF
Sol_140P5426R0006.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

COVER SHEET G001

NORTH

MONROE CO.

CARD SO

UND RO

ADENVIRONMENTAL

KEY WEST

TO 1

CENTER

FLORIDA

BAY

BAY

FLAMINGO

V.C.

SABLE

CAPE

WHITEWATER

OCEAN

V.C.

SOUND

BARNES

MCLAUGHLIN

KEY

MEXICO

GULF OF

OCHOPEE

NAPLES

TO

EVERGLADES

COAST

GULF

V.C.

CITY

FORT MYERS

BIG CYPRESS29

TO

RESERVATION

FL

O

R

ID

A' S

TU

R

N

PI

KE

MONROE COUNTY

HIDDEN LAKE

CENTER

BEARD

DANIEL

LOOP

D

AD

E C

O U

N

TY

M O

N R

O E

C O

U N

TY

ROAD

TAMIAMI

PALM

ROYAL

CENTER

HQ.

RESEARCH

CITY

MAIN

V.C.

FLORIDA

CITY

LEISURE

HOMESTEAD

CHEKIKA

VALLEY

SHARK

MUCCOSUKEE

PRESERVE

COLLIER COUNTY

TAMIAMI TRAIL

NATIONAL

INDIAN

ATLANTIC

LARGO

KEY

NATIONAL

DADE CO.

PARK

BISCAYNE

DRIVECANAL

FORT LAUDERDALE

MIAMI

TO

UNESCO

EVERGLADES NATIONAL PARK

WORLD HERITAGE SITE

PARK OFFICIAL FOR LIMITATIONS.

FEDERAL GOVERNMENT. CHECK WITH LOCAL

PARK HAVE BEEN ACQUIRED BY THE

BOUNDARY OF THE EVERGLADES NATIONAL

NOT ALL LANDS INSIDE THE AUTHORIZED

NOTE

SWAMP OR SLOUGH

PUBLIC AIRPORTS

OBSERVATION TOWER

INFORMATION CENTER

RANGER STATION

PARK HEADQUARTERS

VISITOR CENTER

HQ.

V.C.

CREEK

LEGEND

PARK BOUNDARY

COUNTY LINE

BASIC DATA: BOUNDARY MAPS 160/20,013B 9/89; 160/20,012 3/85; PARK MINI FOLDER 1992; REVISED & REDRAWN 5/93. UPDATED 11/98. SGS.

MEXICO

OF

GULF

LE

E

C O

ATLANTIC

FLORIDA BAY

EVERGLADES

PARK

NATIONAL

KEY LARGO

OCEAN

NORTH MIAMI BEACH

FORT LAUDERDALE

H

EN

D R

Y C

O

KENDALL

PALM BEACH CO.

DADE CO.

BROWARD CO.

FLORIDA CITY

HOMESTEAD

PRINSTON

C O

LL

IE

R C

O

MONROE CO.

PRESERVE

NATIONAL

BIG CYPRESS

MIAMI

NATIONAL

BISCAYNE

PARK

HOLLYWOOD

SCALE IN MILES

10 0 10 20SOUTHERN

FLORIDA

176672

SCALE IN MILES

SCALE IN KILOMETERS

5 0

15105

5 10 LOCATION WITHIN PARK

NAME OF PARK

TITLE OF SHEET

EVERGLADES NATIONAL PARK

PINE ISLAND COMMUNITY

STATEREGION COUNTY

SOUTHEAST FLORIDAMIAMI-DADE

PMIS / PKG. NO.

SHEET

DRAWING NO.

OF 34

DATE:

TECH. REVIEW:

DRAWN:

DESIGNED:REVISIONS SUB SHEET NO.

NATIONAL PARK SERVICE

DENVER SERVICE CENTER

DEPARTMENT OF THE INTERIOR

UNITED STATES

KS/EW

EW / CH

11/21/2022

KS / CH 305612

11/21/2022

BID & CONSTRUCTION ISSUE

JANUARY 29, 2026

11/21/2022

D101

1 DEMOLITION FLOOR PLAN

SCALE 1/4" = 1'

1/4" = 1' - 0" SCALE OF FEET

0'4' 4' 8'

GENERAL NOTES

KEY NOTES

D1 DEMOLISH ALUMINUM-FRAMED SCREENWALL SYSTEM

D2 DEMOLISH CONCRETE CONDENSING UNIT PAD

D3 DEMOLISH ROOF OVERHANG SOFFITS AND VENTS

D4 DEMOLISH CLOSET SLIDING DOORS AND TRACKS. SALVAGE DOORS FOR REUSE.

D5 DEMOLISH KITCHEN CABINETS

D6 DEMOLISH KITCHEN APPLIANCES

D7 DEMOLISH FLOOR TILE (UNIT 119 ONLY)

D8 DEMOLISH SINK VANITIES, WALL CABINETS, MIRRORS, TOWEL AND TOILET PAPER HOLDERS, SOAP TRAYS, ETC AND ALL

FASTENERS OR ANCHORS

D9 DEMOLISH WALL TILE AND SUBSTRATE AND/OR BACKERBOARD.

D10 EXISTING LIGHT SHELF TO REMAIN

D11 DEMOLISH EXISTING WATER-DAMAGED WOOD PLANK ROOF DECK, SHADED AREA INDICATES APPROXIMATE EXTENTS OF KNOWN

DAMAGE. ALL DETERIORATED OR WATER-DAMAGED DECK SHALL BE REMOVED, ADVISE CONTRACT OFFICER IF DAMAGE AREA IS

FOUND TO EXTEND BEYOND THE INDICATED EXTENTS.

D12 DEMOLISH WOOD SHELVING, BRACKETS, SUPPORTS, HOOKS, HANGERS, ANCHORS, ETC. INSIDE OF CLOSET. PATCH HOLES.

D13 SAWCUT AND DEMOLISH CONCRETE FLOOR SLAB FOR EXTENTS REQUIRED TO DEMOLISH EXISTING UNDERSLAB PIPING AND INSTALL NEW WORK. HATCHED AREA INDICATES APPROXIMATE EXTENTS. REFER TO NEW WORK DRAWINGS FOR PATCH AND

REPAIR SCOPE.

D14 DEMOLISH PLASTER AND/OR GYPSUM BOARD WALL FINISHES BOTH SIDES OF WALL AND AS REQUIRED TO DEMOLISH EXISTING

ELECTRICAL AND PLUMBING, AND INSTALL NEW WORK.

D15 DEMOLISH EXISTING WALL TO SLOPED CEILING

D16 DEMOLISH WALLCOVERING FROM FULL EXTENTS OF WALL

D17 REFINISH WOOD SHELVING, DOOR, AND OTHER COMPONENT IN HALLWAY CLOSET.

D18 DEMOLISH SURFACE-MOUNTED HOUSE NUMBERS. EXACT LOCATION MAY VARY AT EACH UNIT.

D19 DEMOLISH HOSE BRACKET

D20 DEMOLISH ANTENNA AND ASSOCIATED BRACKETS AND WIRING. PATCH AND REPAIR EXISTING FINISHES AS REQUIRED. REFER TO

ELECTRICAL FOR SCOPE OF SATELLITE DISH

D21 DEMOLISH CORRUGATED METAL PANEL HURRICANE SHUTTERS AND SUPPORTS AT TOP AND BOTTOM OF WALL. PATCH AND

REPAIR SUBSTRATES.

D22 DEMOLISH PLASTER AND/OR DRYWALL CEILING FINISH AS REQUIRED FOR NEW WORK

D23 REMOVE WALL MOUNTED FIRE EXTINGUISHER

A INTERIOR DOORS: DEMOLISH INTERIOR DOOR. INTERIOR DOOR FRAMES SHALL REMAIN.

B EXTERIOR DOORS: DEMOLISH EXTERIOR DOOR. GENERAL CONTRACTOR TO EVALUATE CONDITION OF FRAME AND ADVISE

CONTRACT OFFICER.

C INTERIOR FINISHES: PLASTER AND PLASTERBOARD WALL AND CEILING FINISHES SHALL BE CUT, TRENCHED, DEMOLISHED AS

REQUIRED TO COMPLETE THE WORK.

D FLOOR FINISHES: TERRAZZO FLOOR AND CONCRETE SLAB SUBSTRATE SHALL BE CUT, TRENCED, DEMOLISHED AS REQUIRED TO INSTALL NEW WORK. MINIMIZE FLOOR SLAB DEMOLITION. LOCATE UNDERSLAB PIPING AND OTHER UTILITIES BY NON-DESTRUCTIVE MEANS PRIOR TO BEGINNING DEMOLITION. SAWCUT TERRAZZO FINISH AND CONCRETE SLAB IN CLEAN

STRAIGHT AND ORTHOGONAL LINES.

E INTERIOR WOOD TRIM: BASE TRIM AND DOOR TRIM SHALL BE DEMOLISHED WHERE REQUIRED TO CARRY OUT NEW WORK.

SALVAGE TRIM FOR REUSE. PROVIDE NEW TRIM WHERE REUSE OF SALVAGED TRIM IS NOT POSSIBLE

F WINDOWS: EXTERIOR WINDOWS ARE NOT IN CONTRACT. PROTECT WINDOWS FROM DAMAGE DURING THE COURSE OF THE

NEW WORK

G ROOF: DEMOLISH ROOFING DOWN TO THE ROOF DECK. INSPECT ROOF DECK FOR WATER DAMAGE AND SUITABILITY FOR INSTALLATION OF NEW ROOF. SURVEY FLAT ROOF AREAS WITH TONGUE AND GROOVE WOOD PLANK DECK FOR WATER DAMAGE.

ADVISE CONTRACT OFFICER OF FINDINGS PRIOR TO CARRYING OUT ADDITIONAL DEMOLITION OR INSTALLING NEW WORK. ANY

DETERIORATED SUBSTRATE (PLYWOOD SHEATHING, BUILDING WRAP, ECT) IS TO BE REMOVED.

H WINDOWS SHADES/BLINDS: DEMOLISH LOUVRE BLINDS, VALENCES, HANGERS AND ALL BRACKETS AND ANCHORS AT EACH WINDOW IN EACH UNIT. PATCH AND REPAIR ANY DAMAGE MADE BY REMOVAL OF BRACKETS, ANCHORS, OR OTHER.

5' -3

8'-1"

'-7

2'-6"

1' -1

33'-0"

1' -5

6'

-5

8' -7

AREA OF FINISH DEMOLITION

(CEILING AND/OR FLOORS)

EXISTING CONSTRUCTION

TO REMAIN

EXISTING CONSTRUCTION

TO BE DEMOLISHED

DOOR TO BE DEMOLISHED

FRAME TO REMAIN

DOOR AND FRAME TO

REMAIN

D101 SCALE 14" = 1'

D101 SCALE 14" = 1'

A INTERIOR DOORS: DEMOLISH INTERIOR DOORS AND HARDWARE. INTERIOR DOOR FRAMES SHALL REMAIN.

B EXTERIOR DOORS: DEMOLISH DOORS AND HARDWARE; GENERAL CONTRACTOR TO EVAULATE CONDITION OF

FRAME AND ADVISE OWNER

C INTERIOR FINISHES: PLASTER AND PLASTERBOARD WALL AND CEILING FINISHES SHALL BE CUT, TRENCHED, DEMOLISHED AS REQUIRED TO INSTALL NEW WORK. MINIMIZE INTERIOR FINISH DEMOLITION, UTILIZE DEMOLISHED CEILING AREA IN CORRIDOR FOR ACCESS TO ATTIC SPACE. FINISH DEMOLITION SHALL BE CARRIED OUT BY MAKING CLEAN STRAIGHT CUTS IN FINISHES AND DEMOLISHING FINISHES WITHIN CUT AREAS. WALL AND CEILING FRAMING SHALL BE PRESERVED UN-DAMAGED. ALL DAMAGE RESULTING FROM DEMO WORK SHALL BE PATCHED AND

REPAIRED TO MATCH ADJACENT WALL FINISH AND TEXTURE.

D FLOOR FINISHES: TERRAZZO FLOOR AND CONCRETE SLAB SUBSTRATE SHALL BE CUT, TRENCED, DEMOLISHED AS REQUIRED TO INSTALL NEW WORK. MINIMIZE FLOOR SLAB DEMOLITION. LOCATE UNDERSLAB PIPING AND OTHER UTILITIES BY NON-DESTRUCTIVE MEANS PRIOR TO BEGINNING DEMOLITION. SAWCUT TERRAZZO FINISH AND

CONCRETE SLAB IN CLEAN STRAIGHT AND ORTHOGONAL LINES.

E INTERIOR WOOD TRIM: BASE TRIM AND DOOR TRIM SHALL BE DEMOLISHED ONLY WHERE REQUIRED TO CARRY OUT NEW WORK. SALVAGE TRIM FOR REUSE. PROVIDE NEW TRIM WHERE REUSE OF SALVAGED TRIM IS NOT

POSSIBLE

F WINDOWS: EXTERIOR WINDOWS ARE NOT IN CONTRACT. PROTECT WINDOWS FROM DAMAGE DURING THE

COURSE OF THE NEW WORK

G ROOF: DEMOLISH ROOFING DOWN TO THE ROOF DECK. INSPECT ROOF DECK FOR WATER DAMAGE AND SUITABILITY FOR INSTALLATION OF NEW ROOF. SURVEY FLAT ROOF AREAS WITH TONGUE AND GROOVE WOOD PLANK DECK FOR WATER DAMAGE BEYOND THE KNOWN DAMAGED AREAS INDICATED ON DRAWINGS. ADVISE CONTRACT OFFICER OF FINDINGS PRIOR TO CARRYING OUT ADDITIONAL DEMOLITION OR INSTALLING NEW WORK.

ANY DETERIORATED SUBSTRATE (PLYWOOD SHEATHING, BUILDING WRAP, ECT) IS TO BE REMOVED.

H WINDOWS SHADES/BLINDS: DEMOLISH LOUVRE BLINDS, VALENCES, HANGERS AND ALL BRACKETS AND ANCHORS AT EACH WINDOW IN EACH UNIT. PATCH AND REPAIR ANY DAMAGE MADE BY REMOVAL OF BRACKETS, ANCHORS, OR OTHER.

D1 DEMOLISH ALUMINUM-FRAMED SCREENWALL SYSTEM

D2 DEMOLISH CONCRETE CONDENSING UNIT PAD

D3 DEMOLISH ROOF OVERHANG SOFFITS AND VENTS

D4 DEMOLISH CLOSET SLIDING DOORS AND TRACKS

D5 DEMOLISH KITCHEN CABINETS

D6 DEMOLISH KITCHEN APPLIANCES

D7 DEMOLISH FLOOR TILE (UNIT 119 ONLY)

D8 DEMOLISH SINK VANITIES, WALL CABINETS, MIRRORS, TOWEL AND TOILET PAPER HOLDERS, SOAP TRAYS, ETC AND

ALL FASTENERS OR ANCHORS

D9 DEMOLISH WALL TILE AND SUBSTRATE AND/OR BACKERBOARD.

D10 EXISTING LIGHT SHELF TO REMAIN - REFER TO ELECTRICAL

D11 DEMOLISH EXISTING WATER-DAMAGED WOOD PLANK ROOF DECK, HATCHED AREA INDICATES APPROXIMATE

EXTENTS OF KNOWN DAMAGE. ALL DETERIORATED OR WATER-DAMAGED DECK SHALL BE REMOVED, ADVISE

CONTRACT OFFICER IF DAMAGE AREA IS FOUND TO EXTEND BEYOND THE INDICATED EXTENTS.

D12 DEMOLISH WOOD SHELVING, BRACKETS, SUPPORTS, HOOKS, HANGERS, ANCHORS, ETC. INSIDE OF CLOSET. PATCH

HOLES.

D13 SAWCUT AND DEMOLISH CONCRETE FLOOR SLAB FOR EXTENTS REQUIRED TO DEMOLISH EXISTING UNDERSLAB PIPING AND INSTALL NEW WORK. HATCHED AREA INDICATES APPROXIMATE EXTENTS. REFER TO NEW WORK

DRAWINGS FOR PATCH AND REPAIR SCOPE.

D14 DEMOLISH PLASTER AND/OR GYPSUM BOARD WALL FINISHES BOTH SIDES OF WALL AND AS REQUIRED TO

DEMOLISH EXISTING ELECTRICAL AND PLUMBING, AND INSTALL NEW WORK.

D15 DEMOLISH EXISTING WALL FROM 42" AFF TO SLOPED CEILING

D16 DEMOLISH WALLCOVERING FROM FULL EXTENTS OF WALL

D17 DEMOLISH CLOSET IN CORRIDOR AND BEDROOM A INCLUDING WOOD SHELVING, DOORS, AND OTHER

COMPONENTS.

D18 DEMOLISH SURFACE-MOUNTED HOUSE NUMBERS. EXACT LOCATION MAY VARY AT EACH UNIT.

D19 DEMOLISH HOSE BRACKET

D20 DEMOLISH ANTENNA AND ASSOCIATED BRACKETS AND WIRING. PATCH AND REPAIR EXISTING FINISHES AS

REQUIRED. REFER TO ELECTRICAL FOR SCOPE OF SATELLITE DISH

D21 DEMOLISH CORRUGATED METAL PANEL HURRICANE SHUTTERS AND SUPPORTS AT TOP AND BOTTOM OF WALL.

PATCH AND REPAIR SUBSTRATES.

D22 DEMOLISH PLASTER AND/OR DRYWALL CEILING FINISH FOR EXTENTS INDICATED.

D23 REMOVE WALL MOUNTED FIRE EXTINGUISHER

349*��)*241.8-�1&:3)7>�)4478 &3)�<&11�&9�:3.9� 11��431>

1/4" = 1' - 0" SCALE OF FEET

0'4' 4' 8'

1*G*3)

SCREENED

PORCH

D

D104 D104

D

4 G*3*7&1�349*8

0*>�349*8

11/21/2022

W

D

WH

A.H.U.

SCREENED

PORCH

LIVING

ROOM

CAR

PORT

KITCHEN

BATHROOM

POWDER

ROOM

BEDROOM

A

BEDROOM

B

BEDROOM

C

05a

CLOSET

04a

CLOSET

CORRIDOR

05b

CLOSET

03a

LAUNDRY

D1

D2

D4

D4

D5 D6

D7

D12 D21

D14

D13

D15

D16

D17

D8,D9

D104

D104

D104

D104

D102

1 DEMOLITION REFLECTED CEILING PLAN

SCALE 1/4" = 1'

24'-2"

2' -9

'-6

54'-0"

4' -6

16'-10"

2' -9

5'

-4

2'-10"

'-4

3'-0"

11'-8"

'-3

AREA OF FINISH DEMOLITION

(CEILING AND/OR FLOORS)

EXISTING CONSTRUCTION

TO REMAIN

EXISTING CONSTRUCTION

TO BE DEMOLISHED

DOOR TO BE DEMOLISHED

FRAME TO REMAIN

DOOR AND FRAME TO

REMAIN

D102 SCALE 14" = 1'

A INTERIOR DOORS: DEMO INTERIOR DOORS AND HARDWARE. INTERIOR DOOR FRAMES SHALL REMAIN.

B EXTERIOR DOORS: DEMOLISH EXTERIOR DOOR AND HARDWARE. GENERAL CONTRACTOR TO EVALUATE CONDITION

OF FRAME AND ADVISE CONTRACT OFFICER. REFER TO KEYNOTES FOR SCOPE OF SCREEN DOORS.

C INTERIOR FINISHES SHALL BE CUT, TRENCHED, DEMOLISHED AS REQUIRED TO INSTALL NEW WORK. MINIMIZE

INTERIOR FINISH DEMO, UTILIZE DEMOLISHED CEILING AREA IN CORRIDOR FOR ACCESS TO ATTIC SPACE. FINISH DEMO SHALL BE CARRIED OUT BY MAKING CLEAN STRAIGHT CUTS IN FINISHES AND DEMOLISHING FINISHES WITHIN CUT AREAS. WALL AND CEILING FRAMING SHALL BE PRESERVED UN-DAMAGED. ALL DAMAGE RESULTING FROM DEMO WORK SHALL BE PATCHED AND REPAIRED TO MATCH ADJACENT WALL FINISH AND TEXTURE.

D FLOOR FINISHES: TERRAZZO FLOOR AND CONCRETE SLAB SUBSTRATE SHALL BE CUT, TRENCED, DEMOLISHED AS REQUIRED TO INSTALL NEW WORK. MINIMIZE FLOOR SLAB DEMO. LOCATE UNDERSLAB PIPING AND OTHER UTILITIES BY NON-DESTRUCTIVE MEANS PRIOR TO BEGINNING DEMO. SAWCUT TERRAZZO FINISH AND CONCRETE

SLAB IN CLEAN STRAIGHT AND ORTHOGONAL LINES.

E INTERIOR WOOD TRIM: BASE TRIM AND DOOR TRIM SHALL BE DEMOLISHED ONLY WHERE REQUIRED TO CARRY OUT NEW WORK. SALVAGE TRIM FOR REUSE. PROVIDE NEW TRIM WHERE REUSE OF SALVAGED TRIM IS NOT

POSSIBLE (PROFILE TO MATCH EXISTING TRIM)

F WINDOWS: EXTERIOR WINDOWS NIC. PROTECT WINDOWS AND HURRICANE SHUTTERS FROM DAMAGE DURING

THE COURSE OF CONSTRUCTION.

G EXTERIOR WOOD SIDING: DEMO EXISTING WOOD SIDING AND FASTENERS IN ENTIRETY. REMOVE BUILDING PAPER OR BUILDING WRAP IF PRESENT. ADVISE CONTRACT OFFICER OF DETERIORATED SUBSTRATE AND AWAIT DIRECTION

ON REPLACEMENT MATERIALS AND METHODS.

H WINDOWS SHADES/BLINDS: DEMO LOUVRE BLINDS, VALENCES, HANGERS AND ALL BRACKETS AND ANCHORS AT EACH WINDOW AND SLIDING DOOR IN EACH UNIT. PATCH AND REPAIR ANY DAMAGE MADE BY REMOVAL OF

BRACKETS, ANCHORS, OR OTHER COMPONENTS TO MATCH ADJACENT EXISTING SURFACES.

D1 DEMOLISH ALUMINUM-FRAMED SCREENWALL SYSTEM

D2 DEMOLISH CONCRETE CONDENSING UNIT PAD

D3 DEMOLISH ROOF OVERHANG SOFFITS AND VENTS

D4 DEMOLISH CLOSET SLIDING DOORS AND TRACKS

D5 DEMOLISH KITCHEN CABINETS

D6 DEMOLISH KITCHEN APPLIANCES

D7 DEMOLISH FLOOR TILE (UNIT 119 ONLY)

D8 DEMOLISH SINK VANITIES, WALL CABINETS, MIRRORS, TOWEL AND TOILET PAPER HOLDERS, SOAP TRAYS, ETC AND

ALL FASTENERS OR ANCHORS

D9 DEMOLISH WALL TILE AND SUBSTRATE AND/OR BACKERBOARD.

D10 EXISTING LIGHT SHELF TO REMAIN - REFER TO ELECTRICAL

D11 DEMOLISH EXISTING WATER-DAMAGED WOOD PLANK ROOF DECK, HATCHED AREA INDICATES APPROXIMATE

EXTENTS OF KNOWN DAMAGE. ALL DETERIORATED OR WATER-DAMAGED DECK SHALL BE REMOVED, ADVISE

CONTRACT OFFICER IF DAMAGE AREA IS FOUND TO EXTEND BEYOND THE INDICATED EXTENTS.

D12 DEMOLISH WOOD SHELVING, BRACKETS, SUPPORTS, HOOKS, HANGERS, ANCHORS, ETC. INSIDE OF CLOSET. PATCH

HOLES.

D13 SAWCUT AND DEMOLISH CONCRETE FLOOR SLAB FOR EXTENTS REQUIRED TO DEMOLISH EXISTING UNDERSLAB PIPING AND INSTALL NEW WORK. HATCHED AREA INDICATES APPROXIMATE EXTENTS. REFER TO NEW WORK

DRAWINGS FOR PATCH AND REPAIR SCOPE.

D14 DEMOLISH PLASTER AND/OR GYPSUM BOARD WALL FINISHES BOTH SIDES OF WALL AND AS REQUIRED TO

DEMOLISH EXISTING ELECTRICAL AND PLUMBING, AND INSTALL NEW WORK.

D15 DEMOLISH EXISTING WALL FROM 42" AFF TO SLOPED CEILING

D16 DEMOLISH WALLCOVERING FROM FULL EXTENTS OF WALL

D17 DEMOLISH CLOSET IN CORRIDOR AND BEDROOM A INCLUDING WOOD SHELVING, DOORS, AND OTHER

COMPONENTS.

D18 DEMOLISH SURFACE-MOUNTED HOUSE NUMBERS. EXACT LOCATION MAY VARY AT EACH UNIT.

D19 DEMOLISH HOSE BRACKET

D20 DEMOLISH ANTENNA AND ASSOCIATED BRACKETS AND WIRING. PATCH AND REPAIR EXISTING FINISHES AS

REQUIRED. REFER TO ELECTRICAL FOR SCOPE OF SATELLITE DISH

D21 DEMOLISH CORRUGATED METAL PANEL HURRICANE SHUTTERS AND SUPPORTS AT TOP AND BOTTOM OF WALL.

PATCH AND REPAIR SUBSTRATES.

D22 DEMOLISH PLASTER AND/OR DRYWALL CEILING FINISH FOR EXTENTS INDICATED.

0*>�349*8

G*3*7&1�349*8

1/4" = 1' - 0" SCALE OF FEET

0'4' 4' 8'

1*G*3)

11/21/2022

RIDGE BEAM

CATHEDRAL

CEILING

SCREENED

PORCH

LIVING

ROOM

CAR

PORT

KITCHEN

BATHROOM

POWDER

ROOM

BEDROOM

A

BEDROOM

B

BEDROOM

C

0505a

CLOSET

04a

CLOSET

CORRIDOR

05b

CLOSET

03a

LAUNDRY

54'-0" +/- (V.I.F.)

'-6

(V .I.

F.

D3

D3

D22

D11

D10

D10

21'-5" +/- (V.I.F.)

40'-0" +/- (V.I.F.)

'-1

0"

(V

.I.

F.

'-1

0"

(V

.I.

F.

2' -7

(V .I.

F.

'-3

(V .I.

F.

GENERAL NOTES

KEY NOTES

D1 DEMOLISH ALUMINUM-FRAMED SCREENWALL SYSTEM

D2 DEMOLISH CONCRETE CONDENSING UNIT PAD

D3 DEMOLISH ROOF OVERHANG SOFFITS AND VENTS

D4

D5 DEMOLISH KITCHEN CABINETS

D6 DEMOLISH KITCHEN APPLIANCES

D7 DEMOLISH FLOOR TILE (UNIT 119 ONLY)

D8 DEMOLISH SINK VANITIES, WALL CABINETS, MIRRORS, TOWEL AND TOILET PAPER HOLDERS, SOAP TRAYS, ETC AND ALL

FASTENERS OR ANCHORS

D9 DEMOLISH WALL TILE AND SUBSTRATE AND/OR BACKERBOARD.

D10 EXISTING LIGHT SHELF TO REMAIN

D11 DEMOLISH EXISTING WATER-DAMAGED WOOD PLANK ROOF DECK, SHADED AREA INDICATES APPROXIMATE EXTENTS OF KNOWN

DAMAGE. ALL DETERIORATED OR WATER-DAMAGED DECK SHALL BE REMOVED, ADVISE CONTRACT OFFICER IF DAMAGE AREA IS

FOUND TO EXTEND BEYOND THE INDICATED EXTENTS.

D12 DEMOLISH WOOD SHELVING, BRACKETS, SUPPORTS, HOOKS, HANGERS, ANCHORS, ETC. INSIDE OF CLOSET. PATCH HOLES.

D13 SAWCUT AND DEMOLISH CONCRETE FLOOR SLAB FOR EXTENTS REQUIRED TO DEMOLISH EXISTING UNDERSLAB PIPING AND INSTALL NEW WORK. HATCHED AREA INDICATES APPROXIMATE EXTENTS. REFER TO NEW WORK DRAWINGS FOR PATCH AND

REPAIR SCOPE.

D14 DEMOLISH PLASTER AND/OR GYPSUM BOARD WALL FINISHES BOTH SIDES OF WALL AND AS REQUIRED TO DEMOLISH EXISTING

ELECTRICAL AND PLUMBING, AND INSTALL NEW WORK.

D15 DEMOLISH EXISTING WALL TO SLOPED CEILING

D16 DEMOLISH WALLCOVERING FROM FULL EXTENTS OF WALL

D17

D18 DEMOLISH SURFACE-MOUNTED HOUSE NUMBERS. EXACT LOCATION MAY VARY AT EACH UNIT.

D19 DEMOLISH HOSE BRACKET

D20 DEMOLISH ANTENNA AND ASSOCIATED BRACKETS AND WIRING. PATCH AND REPAIR EXISTING FINISHES AS REQUIRED. REFER TO

ELECTRICAL FOR SCOPE OF SATELLITE DISH

D21 DEMOLISH CORRUGATED METAL PANEL HURRICANE SHUTTERS AND SUPPORTS AT TOP AND BOTTOM OF WALL. PATCH AND

REPAIR SUBSTRATES.

D22 DEMOLISH PLASTER AND/OR DRYWALL CEILING FINISH AS REQUIRED FOR NEW WORK

D23 REMOVE WALL MOUNTED FIRE EXTINGUISHER

A INTERIOR DOORS: DEMOLISH INTERIOR DOOR. INTERIOR DOOR FRAMES SHALL REMAIN.

B EXTERIOR DOORS: DEMOLISH EXTERIOR DOOR. GENERAL CONTRACTOR TO EVALUATE CONDITION OF FRAME AND ADVISE

CONTRACT OFFICER.

C INTERIOR FINISHES: PLASTER AND PLASTERBOARD WALL AND CEILING FINISHES SHALL BE CUT, TRENCHED, DEMOLISHED AS

REQUIRED TO COMPLETE THE WORK.

D FLOOR FINISHES: TERRAZZO FLOOR AND CONCRETE SLAB SUBSTRATE SHALL BE CUT, TRENCED, DEMOLISHED AS REQUIRED TO INSTALL NEW WORK. MINIMIZE FLOOR SLAB DEMOLITION. LOCATE UNDERSLAB PIPING AND OTHER UTILITIES BY NON-DESTRUCTIVE MEANS PRIOR TO BEGINNING DEMOLITION. SAWCUT TERRAZZO FINISH AND CONCRETE SLAB IN CLEAN

STRAIGHT AND ORTHOGONAL LINES.

E INTERIOR WOOD TRIM: BASE TRIM AND DOOR TRIM SHALL BE DEMOLISHED WHERE REQUIRED TO CARRY OUT NEW WORK.

SALVAGE TRIM FOR REUSE. PROVIDE NEW TRIM WHERE REUSE OF SALVAGED TRIM IS NOT POSSIBLE

F WINDOWS: EXTERIOR WINDOWS ARE NOT IN CONTRACT. PROTECT WINDOWS FROM DAMAGE DURING THE COURSE OF THE

NEW WORK

G ROOF: DEMOLISH ROOFING DOWN TO THE ROOF DECK. INSPECT ROOF DECK FOR WATER DAMAGE AND SUITABILITY FOR INSTALLATION OF NEW ROOF. SURVEY FLAT ROOF AREAS WITH TONGUE AND GROOVE WOOD PLANK DECK FOR WATER DAMAGE.

ADVISE CONTRACT OFFICER OF FINDINGS PRIOR TO CARRYING OUT ADDITIONAL DEMOLITION OR INSTALLING NEW WORK. ANY

DETERIORATED SUBSTRATE (PLYWOOD SHEATHING, BUILDING WRAP, ECT) IS TO BE REMOVED.

H WINDOWS SHADES/BLINDS: DEMOLISH LOUVRE BLINDS, VALENCES, HANGERS AND ALL BRACKETS AND ANCHORS AT EACH WINDOW IN EACH UNIT. PATCH AND REPAIR ANY DAMAGE MADE BY REMOVAL OF BRACKETS, ANCHORS, OR OTHER.

DEMOLISH CLOSET SLIDING DOORS AND TRACKS. SALVAGE DOORS FOR REUSE.

REFINISH WOOD SHELVING, DOOR, AND OTHER COMPONENT IN HALLWAY CLOSET.

'-0

'-0

'-0

22'-10" 23'-7"

82'-6"

48'-6"

'-0

36'-1"

3' -0

'-0

3' -0

3'-0"

3'-0"

8' -0

9' -0

D103 SCALE 14" = 1'

A INTERIOR DOORS: DEMO INTERIOR DOORS AND HARDWARE. INTERIOR DOOR FRAMES SHALL REMAIN.

B EXTERIOR DOORS: DEMOLISH EXTERIOR DOOR AND HARDWARE. GENERAL CONTRACTOR TO EVALUATE CONDITION

OF FRAME AND ADVISE CONTRACT OFFICER. REFER TO KEYNOTES FOR SCOPE OF SCREEN DOORS.

C INTERIOR FINISHES SHALL BE CUT, TRENCHED, DEMOLISHED AS REQUIRED TO INSTALL NEW WORK. MINIMIZE

INTERIOR FINISH DEMO, UTILIZE DEMOLISHED CEILING AREA IN CORRIDOR FOR ACCESS TO ATTIC SPACE. FINISH DEMO SHALL BE CARRIED OUT BY MAKING CLEAN STRAIGHT CUTS IN FINISHES AND DEMOLISHING FINISHES WITHIN CUT AREAS. WALL AND CEILING FRAMING SHALL BE PRESERVED UN-DAMAGED. ALL DAMAGE RESULTING FROM DEMO WORK SHALL BE PATCHED AND REPAIRED TO MATCH ADJACENT WALL FINISH AND TEXTURE.

D FLOOR FINISHES: TERRAZZO FLOOR AND CONCRETE SLAB SUBSTRATE SHALL BE CUT, TRENCED, DEMOLISHED AS REQUIRED TO INSTALL NEW WORK. MINIMIZE FLOOR SLAB DEMO. LOCATE UNDERSLAB PIPING AND OTHER UTILITIES BY NON-DESTRUCTIVE MEANS PRIOR TO BEGINNING DEMO. SAWCUT TERRAZZO FINISH AND CONCRETE

SLAB IN CLEAN STRAIGHT AND ORTHOGONAL LINES.

E INTERIOR WOOD TRIM: BASE TRIM AND DOOR TRIM SHALL BE DEMOLISHED ONLY WHERE REQUIRED TO CARRY OUT NEW WORK. SALVAGE TRIM FOR REUSE. PROVIDE NEW TRIM WHERE REUSE OF SALVAGED TRIM IS NOT

POSSIBLE (PROFILE TO MATCH EXISTING TRIM)

F WINDOWS: EXTERIOR WINDOWS NIC. PROTECT WINDOWS AND HURRICANE SHUTTERS FROM DAMAGE DURING

THE COURSE OF CONSTRUCTION.

G EXTERIOR WOOD SIDING: DEMO EXISTING WOOD SIDING AND FASTENERS IN ENTIRETY. REMOVE BUILDING PAPER OR BUILDING WRAP IF PRESENT. ADVISE CONTRACT OFFICER OF DETERIORATED SUBSTRATE AND AWAIT DIRECTION

ON REPLACEMENT MATERIALS AND METHODS.

H WINDOWS SHADES/BLINDS: DEMO LOUVRE BLINDS, VALENCES, HANGERS AND ALL BRACKETS AND ANCHORS AT EACH WINDOW AND SLIDING DOOR IN EACH UNIT. PATCH AND REPAIR ANY DAMAGE MADE BY REMOVAL OF

BRACKETS, ANCHORS, OR OTHER COMPONENTS TO MATCH ADJACENT EXISTING SURFACES.

DR01 DEMOLISH ASPHALT ROLL-ROOFING, UNDERLAYMENT, EDGE TRIMS, FASCIAS AND DRIP EDGES. DETERIORATED SUBSTRATES OR SHEATHING SHALL BE REMOVED AND REPLACED. ADVISE CONTRACT OFFICER OF DETERIORATED

MATERIALS AND AWAIT DIRECTION ON REPLACEMENT MATERIALS AND METHODS.

DR02

DEMOLISH ASPHALT ROLL ROOFING AND SUBSTRATE AT GABLE ENDS, UNIT #119 ONLY.

DR03 AT UNIT #119 DEMOLISH ASPHALT SHINGLE ROOFING FROM SLOPED ROOF AREA. DEMOLISH UNDERLAYMENT, EDGE TRIMS, FASCIAS AND DRIP EDGES. DETERIORATED SUBSTRATES OR SHEATHING SHALL BE REMOVED AND REPLACED. ADVISE CONTRACT OFFICER OF DETERIORATED MATERIALS AND AWAIT DIRECTION ON REPLACEMENT

MATERIALS AND METHODS.

DR04 AT UNITS #120 AND #124 DEMOLISH ASPHALT ROLL-ROOFING FROM LOW SLOPED ROOF AREA. DEMOLISH UNDERLAYMENT, EDGE TRIMS, FASCIAS AND DRIP EDGES. DETERIORATED SUBSTRATES OR SHEATHING SHALL BE REMOVED AND REPLACED. ADVISE CONTRACT OFFICER OF DETERIORATED MATERIALS AND AWAIT DIRECTION

ON REPLACEMENT MATERIALS AND METHODS.

DR05 REMOVE AND SALVAGE EXISTING ROOF VENTILATORS FOR RE-INSTALLATION

DR06 DEMOLISH ROOF AND STACK VENTS

SL

O

PE

SL

O

PE

G*3*7&1�349*8

1/4" = 1' - 0" SCALE OF FEET

0'4' 4' 8'

0*>�349*8

D102 SCALE 18" = 1'

D102 SCALE 18" = 1'

D102 SCALE 18" = 1'

D102 SCALE 18" = 1'

A INTERIOR DOORS: DEMO INTERIOR DOORS AND HARDWARE. INTERIOR DOOR FRAMES SHALL REMAIN.

B EXTERIOR DOORS: DEMOLISH EXTERIOR DOOR AND HARDWARE. GENERAL CONTRACTOR TO EVALUATE CONDITION

OF FRAME AND ADVISE CONTRACT OFFICER. REFER TO KEYNOTES FOR SCOPE OF SCREEN DOORS.

C INTERIOR FINISHES SHALL BE CUT, TRENCHED, DEMOLISHED AS REQUIRED TO INSTALL NEW WORK. MINIMIZE

INTERIOR FINISH DEMO, UTILIZE DEMOLISHED CEILING AREA IN CORRIDOR FOR ACCESS TO ATTIC SPACE. FINISH DEMO SHALL BE CARRIED OUT BY MAKING CLEAN STRAIGHT CUTS IN FINISHES AND DEMOLISHING FINISHES WITHIN CUT AREAS. WALL AND CEILING FRAMING SHALL BE PRESERVED UN-DAMAGED. ALL DAMAGE RESULTING FROM DEMO WORK SHALL BE PATCHED AND REPAIRED TO MATCH ADJACENT WALL FINISH AND TEXTURE.

D FLOOR FINISHES: TERRAZZO FLOOR AND CONCRETE SLAB SUBSTRATE SHALL BE CUT, TRENCED, DEMOLISHED AS REQUIRED TO INSTALL NEW WORK. MINIMIZE FLOOR SLAB DEMO. LOCATE UNDERSLAB PIPING AND OTHER UTILITIES BY NON-DESTRUCTIVE MEANS PRIOR TO BEGINNING DEMO. SAWCUT TERRAZZO FINISH AND CONCRETE

SLAB IN CLEAN STRAIGHT AND ORTHOGONAL LINES.

E INTERIOR WOOD TRIM: BASE TRIM AND DOOR TRIM SHALL BE DEMOLISHED ONLY WHERE REQUIRED TO CARRY OUT NEW WORK. SALVAGE TRIM FOR REUSE. PROVIDE NEW TRIM WHERE REUSE OF SALVAGED TRIM IS NOT

POSSIBLE (PROFILE TO MATCH EXISTING TRIM)

F WINDOWS: EXTERIOR WINDOWS NIC. PROTECT WINDOWS AND HURRICANE SHUTTERS FROM DAMAGE DURING

THE COURSE OF CONSTRUCTION.

G EXTERIOR WOOD SIDING: DEMO EXISTING WOOD SIDING AND FASTENERS IN ENTIRETY. REMOVE BUILDING PAPER OR BUILDING WRAP IF PRESENT. ADVISE CONTRACT OFFICER OF DETERIORATED SUBSTRATE AND AWAIT DIRECTION

ON REPLACEMENT MATERIALS AND METHODS.

H WINDOWS SHADES/BLINDS: DEMO LOUVRE BLINDS, VALENCES, HANGERS AND ALL BRACKETS AND ANCHORS AT EACH WINDOW AND SLIDING DOOR IN EACH UNIT. PATCH AND REPAIR ANY DAMAGE MADE BY REMOVAL OF

BRACKETS, ANCHORS, OR OTHER COMPONENTS TO MATCH ADJACENT EXISTING SURFACES.

D1 DEMOLISH ALUMINUM-FRAMED SCREENWALL SYSTEM

D2 DEMOLISH CONCRETE CONDENSING UNIT PAD

D3 DEMOLISH ROOF OVERHANG SOFFITS AND VENTS

D4 DEMOLISH CLOSET SLIDING DOORS AND TRACKS

D5 DEMOLISH KITCHEN CABINETS

D6 DEMOLISH KITCHEN APPLIANCES

D7 DEMOLISH FLOOR TILE (UNIT 119 ONLY)

D8 DEMOLISH SINK VANITIES, WALL CABINETS, MIRRORS, TOWEL AND TOILET PAPER HOLDERS, SOAP TRAYS, ETC AND

ALL FASTENERS OR ANCHORS

D9 DEMOLISH WALL TILE AND SUBSTRATE AND/OR BACKERBOARD.

D10 EXISTING LIGHT SHELF TO REMAIN - REFER TO ELECTRICAL

D11 DEMOLISH EXISTING WATER-DAMAGED WOOD PLANK ROOF DECK, HATCHED AREA INDICATES APPROXIMATE

EXTENTS OF KNOWN DAMAGE. ALL DETERIORATED OR WATER-DAMAGED DECK SHALL BE REMOVED, ADVISE

CONTRACT OFFICER IF DAMAGE AREA IS FOUND TO EXTEND BEYOND THE INDICATED EXTENTS.

D12 DEMOLISH WOOD SHELVING, BRACKETS, SUPPORTS, HOOKS, HANGERS, ANCHORS, ETC. INSIDE OF CLOSET. PATCH

HOLES.

D13 SAWCUT AND DEMOLISH CONCRETE FLOOR SLAB FOR EXTENTS REQUIRED TO DEMOLISH EXISTING UNDERSLAB PIPING AND INSTALL NEW WORK. HATCHED AREA INDICATES APPROXIMATE EXTENTS. REFER TO NEW WORK

DRAWINGS FOR PATCH AND REPAIR SCOPE.

D14 DEMOLISH PLASTER AND/OR GYPSUM BOARD WALL FINISHES BOTH SIDES OF WALL AND AS REQUIRED TO

DEMOLISH EXISTING ELECTRICAL AND PLUMBING, AND INSTALL NEW WORK.

D15 DEMOLISH EXISTING WALL FROM 42" AFF TO SLOPED CEILING

D16 DEMOLISH WALLCOVERING FROM FULL EXTENTS OF WALL

D17 DEMOLISH CLOSET IN CORRIDOR AND BEDROOM A INCLUDING WOOD SHELVING, DOORS, AND OTHER

COMPONENTS.

D18 DEMOLISH SURFACE-MOUNTED HOUSE NUMBERS. EXACT LOCATION MAY VARY AT EACH UNIT.

D19 DEMOLISH HOSE BRACKET

D20 DEMOLISH ANTENNA AND ASSOCIATED BRACKETS AND WIRING. PATCH AND REPAIR EXISTING FINISHES AS

REQUIRED. REFER TO ELECTRICAL FOR SCOPE OF SATELLITE DISH

D21 DEMOLISH CORRUGATED METAL PANEL HURRICANE SHUTTERS AND SUPPORTS AT TOP AND BOTTOM OF WALL.

PATCH AND REPAIR SUBSTRATES.

D22 DEMOLISH PLASTER AND/OR DRYWALL CEILING FINISH FOR EXTENTS INDICATED.

1/4" = 1' - 0" SCALE OF FEET

0'4' 4' 8'

0*>�349*8

G*3*7&1�349*8

OPEN

TO

BEYOND

OPEN

TO

BEYOND

A101

1 FLOOR PLAN

SLAB REPAIR AND INFILL DETAIL

A101

2 CONCRETE HVAC PAD DETAIL

A101

SCALE: B

KEY NOTES

GENERAL NOTES

SCALE: B

SCALE: A

WINDOW SHADE SCHEDULE

A PROTECT ALL EXISTING FINISHES FROM DAMAGE DURING THE COURSE OF THE WORK.

PROVIDE PROTECTIVE FLOOR COVERINGS FOR FULL EXTENT OF INTERIOR FINISH FLOORS.

PROTECT CABINETS, APPLIANCES, FIXTURES AND OTHER EXISTING-TO-REMAIN ITEMS

WITH PLASTIC OR OTHER PROTECTIVE MEANS.

B INTERIOR PAINTING SCOPE:- EXISTING PAINTED INTERIOR SURFACES SHALL BE PAINTED.

INCLUDING BUT NOT LIMITED TO WALLS, CEILINGS, TRIM, DOORS, CLOSET INTERIORS

AND CLOSET DOORS, AND EXPOSED WOOD ROOF DECK PLANKS.- PREPARE ALL

SURFACES BY REMOVING EXISTING FASTENERS, ANCHORS OR OTHER ITEMS. FILL AND

PATCH ALL HOLES AND CRACKS. SCRAPE AND REMOVE FLAKING OR UNADHERED PAINT.-

REFER TO PAINTING SPECIFICATION FOR PAINT SYSTEMSPAINT COLOR SELECTIONS:-

PNT-1: CEILINGS- PNT-2: INTERIOR WALLS- PNT-3: CLOSETS AND SHELVING INTERIORS

AND TRIM

C DIMENSIONS PROVIDED ARE APPROXIMATE. ALL DIMENSIONS SHALL BE FIELD VERIFIED

BY CONTRACTOR.

D NEW INTERIOR PARTITION ASSEMBLY SHALL BE 2X4 WOOD FRAMING WITH 1/2"

DRYWALL EACH SIDE.

1 NEW CONCRETE PAD FOR CONDENSING UNIT. COORDINATE SIZE WITH MANUFACTURER

RECOMMENDATIONS

2 NEW VENTED FIBER CEMENT SOFFIT PANELS, DASHED LINE INDICATES EXTENT OF

VENTED PANELS.

3 NEW TERRAZZO FINISH ON NEW SLAB INFILL

4 PROVIDE HURRICANE PANELING SYSTEM MATCHING EXISTING DEMOLISHED SYSTEM.

REFER TO NOTES ON A301.

5 REPLACE WOOD ROOF DECK PLANKS WITH NEW PLANKS OF SAME DIMENSION

6 REPLACE EXISTING CLOSET DOORS, HARDWARE AND SLIDING TRACKS AT EACH CLOSET

AS REQUIRED. SALVAGE & REUSE EXISTING COMPONENTS AS POSSIBLE. ADD SHELF AND

POLE AT EACH CLOSET.

7 PATCH EXISTING WALL AS REQUIRED FOR INSTALLATION OF ELECTRICAL PANEL (REFER

TO ELECTRICAL)

8 WALL MOUNTED FIRE EXTINGUISHER -- REFER TO SPECIFICATIONS

9 REFER TO HARDWARE SET 10 IN SPECIFICATION SECTION 08 71 00 FOR CLOSET

HARDWARE

10 24x24 PLYWOOD ACCESS PANEL (PTD) IN DRYWALL CEILING - COORDINATE FINAL

LOCATION WITH WORK IN ATTIC - HEADERS TO MATCH BOTTOM CORD OF ROOF TRUSS -

1x3 WOOD TRIM (PTD) WITH 1/2" FOAM TAPE ALL SIDES

11 DRYWALL CEILING FINISH (PAINTED) MATCH EXISTING CEILING HEIGHT AND TIE INTO

EXISTING BULKHEAD IN LIVING ROOM (01)

12 DRYWALL CEILING FINISH (PAINTED) MATCH EXISTING CEILING SLOPE

WS-1 ROLLER WINDOW SHADE -- REFER TO SPECIFICATIONS

Pantry

HVAC

Closet

W

D

WH

A.H.U.

SCREENED

PORCH

LIVING

ROOM

CAR

PORT

KITCHEN

BATHROOM

POWDER

ROOM

BEDROOM

A

BEDROOM

B

BEDROOM

C

04a

CLOSET

CORRIDOR

03a

LAUNDRY

01a

05a

03d

04a

04b

04c

03c

03b

01b

03a

XX-XX 1

A401

XX-XX 4

0905b

XX-XX 4

SW-1

XX-XX 6

XX-XX 6

SAND, PATCH & APPLY EPOXY

COAT OVER SLAB IN COLOR TO

MATCH EXISTING @ PORCH

RESTORE EXIST TERRAZZO FLOORING

@ ALL LOC. U.O.N. REMOVE SEALER,

FINE GRIND, ADD GROUT AS NEEDED,

POLISH 200 GRIT AND APPLY NEW

REPLACE EXIST

SLABS IN-KIND @

ALL ENTRIES (TYP)

REBUILD CLOSET WALL TO

MEET 36" MIN REQ

CLEARANCE. RELOCATE

DOORS 01b AND 03c AS REQ

36" MIN

A201

A201

A201

A201

2' -9

NEW TERRAZZO FINISH

CONCRETE SLAB INFILL

0' -4

0'-4"

3" MIN. #57 STONE

4' x4' WELDED WIRE

MESH REINFORCING

AT MID-POINT OF SLAB

3" MIN. #57 STONE

0' -6

0' -4

HATCHED AREA INDICATES APPROXIMATE EXTENTS OF

NEW TERRAZZO FLOOR FINISH. COORDINATE WITH

EXTENTS OF REQUIRED SLAB DEMOLITION AND INFILL

HATCHED AREA INDICATES APPROXIMATE EXTENTS OF NEW

CEILING FINISH. COORDINATE WITH EXTENTS OF REQUIRED

CEILING DEMO.

A101

01a

05a

03d

04a

04b

04c

03c

03b

03a

SCALE: BA101 A101A101

A PROTECT ALL EXISTING FINISHES FROM DAMAGE DURING THE COURSE OF THE

WORK. PROVIDE PROTECTIVE FLOOR COVERINGS FOR FULL EXTENT OF

INTERIOR FINISH FLOORS. PROTECT CABINETS, APPLIANCES, FIXTURES AND

OTHER EXISTING-TO-REMAIN ITEMS WITH PLASTIC OR OTHER PROTECTIVE

MEANS.

B INTERIOR PAINTING SCOPE:

- EXISTING PAINTED INTERIOR SURFACES SHALL BE PAINTED. INCLUDING BUT

NOT LIMITED TO WALLS, CEILINGS, TRIM, DOORS, CLOSET INTERIORS AND

CLOSET DOORS, AND EXPOSED WOOD ROOF DECK PLANKS.

- PREPARE ALL SURFACES BY REMOVING EXISTING FASTENERS, ANCHORS OR

OTHER ITEMS. FILL AND PATCH ALL HOLES AND CRACKS. SCRAPE AND REMOVE

FLAKING OR UNADHERED PAINT.

- REFER TO PAINTING SPECIFICATION FOR PAINT SYSTEMS

PAINT COLOR SELECTIONS:

- PNT-1: CEILINGS

- PNT-2: INTERIOR WALLS

- PNT-3: CLOSETS AND SHELVING INTERIORS AND TRIM

C DIMENSIONS PROVIDED ARE APPROXIMATE. ALL DIMENSIONS SHALL BE FIELD

VERIFIED BY CONTRACTOR.

D NEW INTERIOR PARTITION ASSEMBLY SHALL BE 2X4 WOOD FRAMING WITH

1/2" DRYWALL EACH SIDE.

1 NEW CONCRETE PAD FOR CONDENSING UNIT. COORDINATE SIZE WITH

MANUFACTURER RECOMMENDATIONS

2 NEW VENTED FIBER CEMENT SOFFIT PANELS, DASHED LINE INDICATES EXTENT

OF VENTED PANELS.

3 NEW TERRAZZO FINISH ON NEW SLAB INFILL

4 PROVIDE HURRICANE PANELING SYSTEM MATCHING EXISTING DEMOLISHED

SYSTEM. REFER TO NOTES ON A301.

5 REPLACE WOOD ROOF DECK PLANKS WITH NEW PLANKS OF SAME DIMENSION

6 DEMOLISH AND REPLACE EXISTING IN-KIND CLOSET DOORS, HARDWARE AND

SLIDING TRACKS AT EACH CLOSET. REFER TO 2/A401 DETAILS FOR SCOPE AND

ARRANGEMENT.

7 PATCH EXISTING WALL AS REQUIRED FOR INSTALLATION OF ELECTRICAL PANEL

(REFER TO ELECTRICAL)

8 WALL MOUNTED FIRE EXTINGUISHER -- REFER TO SPECIFICATIONS

9 REFER TO HARDWARE SET 10 IN SPECIFICATION SECTION 08 71 00 FOR CLOSET

HARDWARE

2X4 STUD WALL,

FLOOR TO ROOF

DECK PT SILL PLATE,

LEAD BOTH SIDES

WITH FIBER CEMENT

PANEL CLADDING.

NOTE:

NEW WORK AT UNIT

#119 ONLY.

03a

LAUNDRY

PORCH

SCREENED

1/4" = 1' - 0" SCALE OF FEET

0'4' 4' 8'

1 1/2" = 1' - 0" SCALE OF FEET

0'1' 1'6"

0*>�349*8

G*3*7&1�349*8

1*G*3)

A2

A201 A201

A2

0905b

02a

02b

SCALE: BSCALE: A

SCALE: A

B

A

<.3)4<�8-&)*�8(-*):1*

WS-1 ROLLER WINDOW SHADE -- REFER TO SPECIFICATIONS

WS-2L

VERTICAL LOUVER BLINDS -- CONTROL ON RIGHT; DRAW/ STACK ONE

WAY, STACK LEFT; LENGTH TO BE WINDOW OPENING PLUS 1 1/2" --

REFER TO VERTICAL LOUVER BLIND SPECIFICATION

WS-2R

VERTICAL LOUVER BLINDS -- CONTROL ON LEFT; DRAW/ STACK ONE WAY,

STACK RIGHT; LENGTH TO BE WINDOW OPENING PLUS 1 1/2" -- REFER TO

VERTICAL LOUVER BLIND SPECIFICATION

11/21/2022

2' -9

NEW TERRAZZO FINISH

CONCRETE SLAB INFILL

0' -4

0'-4"

3" MIN. #57 STONE

4' x4' WELDED WIRE

MESH REINFORCING

AT MID-POINT OF SLAB

3" MIN. #57 STONE

0' -6

0' -4

HATCHED AREA INDICATES APPROXIMATE EXTENTS OF

NEW TERRAZZO FLOOR FINISH. COORDINATE WITH

EXTENTS OF REQUIRED SLAB DEMOLITION AND INFILL

HATCHED AREA INDICATES APPROXIMATE EXTENTS OF NEW

CEILING FINISH. COORDINATE WITH EXTENTS OF REQUIRED

CEILING DEMO.

A101

01a

05a

03d

04a

04b

04c

03c

03b

03a

SCALE: BA101 A101A101

A PROTECT ALL EXISTING FINISHES FROM DAMAGE DURING THE COURSE OF THE

WORK. PROVIDE PROTECTIVE FLOOR COVERINGS FOR FULL EXTENT OF

INTERIOR FINISH FLOORS. PROTECT CABINETS, APPLIANCES, FIXTURES AND

OTHER EXISTING-TO-REMAIN ITEMS WITH PLASTIC OR OTHER PROTECTIVE

MEANS.

B INTERIOR PAINTING SCOPE:

- EXISTING PAINTED INTERIOR SURFACES SHALL BE PAINTED. INCLUDING BUT

NOT LIMITED TO WALLS, CEILINGS, TRIM, DOORS, CLOSET INTERIORS AND

CLOSET DOORS, AND EXPOSED WOOD ROOF DECK PLANKS.

- PREPARE ALL SURFACES BY REMOVING EXISTING FASTENERS, ANCHORS OR

OTHER ITEMS. FILL AND PATCH ALL HOLES AND CRACKS. SCRAPE AND REMOVE

FLAKING OR UNADHERED PAINT.

- REFER TO PAINTING SPECIFICATION FOR PAINT SYSTEMS

PAINT COLOR SELECTIONS:

- PNT-1: CEILINGS

- PNT-2: INTERIOR WALLS

- PNT-3: CLOSETS AND SHELVING INTERIORS AND TRIM

C DIMENSIONS PROVIDED ARE APPROXIMATE. ALL DIMENSIONS SHALL BE FIELD

VERIFIED BY CONTRACTOR.

D NEW INTERIOR PARTITION ASSEMBLY SHALL BE 2X4 WOOD FRAMING WITH

1/2" DRYWALL EACH SIDE.

1 NEW CONCRETE PAD FOR CONDENSING UNIT. COORDINATE SIZE WITH

MANUFACTURER RECOMMENDATIONS

2 NEW VENTED FIBER CEMENT SOFFIT PANELS, DASHED LINE INDICATES EXTENT

OF VENTED PANELS.

3 NEW TERRAZZO FINISH ON NEW SLAB INFILL

4 PROVIDE HURRICANE PANELING SYSTEM MATCHING EXISTING DEMOLISHED

SYSTEM. REFER TO NOTES ON A301.

5 REPLACE WOOD ROOF DECK PLANKS WITH NEW PLANKS OF SAME DIMENSION

6 DEMOLISH AND REPLACE EXISTING IN-KIND CLOSET DOORS, HARDWARE AND

SLIDING TRACKS AT EACH CLOSET. REFER TO 2/A401 DETAILS FOR SCOPE AND

ARRANGEMENT.

7 PATCH EXISTING WALL AS REQUIRED FOR INSTALLATION OF ELECTRICAL PANEL

(REFER TO ELECTRICAL)

8 WALL MOUNTED FIRE EXTINGUISHER -- REFER TO SPECIFICATIONS

9 REFER TO HARDWARE SET 10 IN SPECIFICATION SECTION 08 71 00 FOR CLOSET

HARDWARE

2X4 STUD WALL,

FLOOR TO ROOF

DECK PT SILL PLATE,

LEAD BOTH SIDES

WITH FIBER CEMENT

PANEL CLADDING.

NOTE:

NEW WORK AT UNIT

#119 ONLY.

03a

LAUNDRY

PORCH

SCREENED

1/4" = 1' - 0" SCALE OF FEET

0'4' 4' 8'

1 1/2" = 1' - 0" SCALE OF FEET

0'1' 1'6"

0*>�349*8

G*3*7&1�349*8

1*G*3)

A2

A201 A201

A2

0905b

02a

02b

SCALE: BSCALE: A

SCALE: A

B

A

<.3)4<�8-&)*�8(-*):1*

WS-1 ROLLER WINDOW SHADE -- REFER TO SPECIFICATIONS

WS-2L

VERTICAL LOUVER BLINDS -- CONTROL ON RIGHT; DRAW/ STACK ONE

WAY, STACK LEFT; LENGTH TO BE WINDOW OPENING PLUS 1 1/2" --

REFER TO VERTICAL LOUVER BLIND SPECIFICATION

WS-2R

VERTICAL LOUVER BLINDS -- CONTROL ON LEFT; DRAW/ STACK ONE WAY,

STACK RIGHT; LENGTH TO BE WINDOW OPENING PLUS 1 1/2" -- REFER TO

VERTICAL LOUVER BLIND SPECIFICATION

11/21/2022

A111

A111

WS-1

WS-1

WS-1

W S-

W

S-

WS-1 WS-1WS-1 WS-1

WS-1 WS-1WS-1 WS-1 WS-1

A102

1 REFLECTED CEILING PLAN

SCALE 1/4" = 1'

RIDGE BEAM

CATHEDRAL

CEILING

SCREENED

PORCH

LIVING

ROOM

CAR

PORT

KITCHEN

BATHROOM

POWDER

ROOM

BEDROOM

A

BEDROOM

B

BEDROOM

C

0505a

CLOSET

04a

CLOSET

CORRIDOR

05b

CLOSET

03a

LAUNDRY

XX-XX 5

11'-6"

'-9

HATCHED AREA INDICATES APPROXIMATE EXTENTS OF

NEW TERRAZZO FLOOR FINISH. COORDINATE WITH

EXTENTS OF REQUIRED SLAB DEMOLITION AND INFILL

HATCHED AREA INDICATES APPROXIMATE EXTENTS OF NEW

CEILING FINISH. COORDINATE WITH EXTENTS OF REQUIRED

CEILING DEMO.

A102 SCALE 14" = 1'

A PROTECT ALL EXISTING FINISHES FROM DAMAGE DURING THE COURSE OF THE

WORK. PROVIDE PROTECTIVE FLOOR COVERINGS FOR FULL EXTENT OF

INTERIOR FINISH FLOORS. PROTECT CABINETS, APPLIANCES, FIXTURES AND

OTHER EXISTING-TO-REMAIN ITEMS WITH PLASTIC OR OTHER PROTECTIVE

MEANS.

B INTERIOR PAINTING SCOPE:

- EXISTING PAINTED INTERIOR SURFACES SHALL BE PAINTED. INCLUDING BUT

NOT LIMITED TO WALLS, CEILINGS, TRIM, DOORS, CLOSET INTERIORS AND

CLOSET DOORS, AND EXPOSED WOOD ROOF DECK PLANKS.

- PREPARE ALL SURFACES BY REMOVING EXISTING FASTENERS, ANCHORS OR

OTHER ITEMS. FILL AND PATCH ALL HOLES AND CRACKS. SCRAPE AND REMOVE

FLAKING OR UNADHERED PAINT.

- REFER TO PAINTING SPECIFICATION FOR PAINT SYSTEMS

PAINT COLOR SELECTIONS:

- PNT-1: CEILINGS

- PNT-2: INTERIOR WALLS

- PNT-3: CLOSETS AND SHELVING INTERIORS AND TRIM

C DIMENSIONS PROVIDED ARE APPROXIMATE. ALL DIMENSIONS SHALL BE FIELD

VERIFIED BY CONTRACTOR.

D NEW INTERIOR PARTITION ASSEMBLY SHALL BE 2X4 WOOD FRAMING WITH

1/2" DRYWALL EACH SIDE.

1 NEW CONCRETE PAD FOR CONDENSING UNIT. COORDINATE SIZE WITH

MANUFACTURER RECOMMENDATIONS

2 NEW VENTED FIBER CEMENT SOFFIT PANELS, DASHED LINE INDICATES EXTENT

OF VENTED PANELS.

3 NEW TERRAZZO FINISH ON NEW SLAB INFILL

4 PROVIDE NEW HURRICANE PANELING SYSTEM MATCHING EXISTING

DEMOLISHED SYSTEM. PROVIDE ALL REQUIRED COMPONENTS INCLUDING BUT

NOT LIMITED TO 0.050 THICK, 2" CORRUGATED ALUMINUM PANELS AND

POWDERCOATED ALUMINUM 2" 'H' HEADER TRACK AND STUDDED ANGLE

BOTTOM TRACK, AND ALL REQUIRED FASTENERS.

5 REPLACE WOOD ROOF DECK PLANKS WITH NEW PLANKS OF SAME DIMENSION

6 DEMOLISH AND REPLACE EXISTING IN-KIND CLOSET DOORS, HARDWARE AND

SLIDING TRACKS AT EACH CLOSET. REFER TO 2/A401 DETAILS FOR SCOPE AND

ARRANGEMENT.

7 PATCH EXISTING WALL AS REQUIRED FOR INSTALLATION OF ELECTRICAL PANEL

(REFER TO ELECTRICAL)

8 WALL MOUNTED FIRE EXTINGUISHER -- REFER TO SPECIFICATIONS

9 REFER TO HARDWARE SET 10 IN SPECIFICATION SECTION 08 71 00 FOR CLOSET

HARDWARE

10 24x24 PLYWOOD ACCESS PANEL (PTD) IN DRYWALL CEILING - COORDINATE

FINAL LOCATION WITH WORK IN ATTIC - HEADERS TO MATCH BOTTOM CORD

OF ROOF TRUSS - 1x3 WOOD TRIM (PTD) WITH 1/2" FOAM TAPE ALL SIDES

0*>�349*8

G*3*7&1�349*8

1/4" = 1' - 0" SCALE OF FEET

0'4' 4' 8'

1*G*3)

11/21/2022

KEY NOTES

GENERAL NOTES

A PROTECT ALL EXISTING FINISHES FROM DAMAGE DURING THE COURSE OF THE WORK.

PROVIDE PROTECTIVE FLOOR COVERINGS FOR FULL EXTENT OF INTERIOR FINISH FLOORS.

PROTECT CABINETS, APPLIANCES, FIXTURES AND OTHER EXISTING-TO-REMAIN ITEMS

WITH PLASTIC OR OTHER PROTECTIVE MEANS.

B INTERIOR PAINTING SCOPE:- EXISTING PAINTED INTERIOR SURFACES SHALL BE PAINTED.

INCLUDING BUT NOT LIMITED TO WALLS, CEILINGS, TRIM, DOORS, CLOSET INTERIORS

AND CLOSET DOORS, AND EXPOSED WOOD ROOF DECK PLANKS.- PREPARE ALL

SURFACES BY REMOVING EXISTING FASTENERS, ANCHORS OR OTHER ITEMS. FILL AND

PATCH ALL HOLES AND CRACKS. SCRAPE AND REMOVE FLAKING OR UNADHERED PAINT.-

REFER TO PAINTING SPECIFICATION FOR PAINT SYSTEMSPAINT COLOR SELECTIONS:-

PNT-1: CEILINGS- PNT-2: INTERIOR WALLS- PNT-3: CLOSETS AND SHELVING INTERIORS

AND TRIM

C DIMENSIONS PROVIDED ARE APPROXIMATE. ALL DIMENSIONS SHALL BE FIELD VERIFIED

BY CONTRACTOR.

D NEW INTERIOR PARTITION ASSEMBLY SHALL BE 2X4 WOOD FRAMING WITH 1/2"

DRYWALL EACH SIDE.

1 NEW CONCRETE PAD FOR CONDENSING UNIT. COORDINATE SIZE WITH MANUFACTURER

RECOMMENDATIONS

2 NEW VENTED FIBER CEMENT SOFFIT PANELS, DASHED LINE INDICATES EXTENT OF

VENTED PANELS.

3 NEW TERRAZZO FINISH ON NEW SLAB INFILL

4 PROVIDE HURRICANE PANELING SYSTEM MATCHING EXISTING DEMOLISHED SYSTEM.

REFER TO NOTES ON A301.

5 REPLACE WOOD ROOF DECK PLANKS WITH NEW PLANKS OF SAME DIMENSION

6 DEMOLISH AND REPLACE EXISTING ICLOSET DOORS, HARDWARE AND SLIDING TRACKS

AT EACH CLOSET. REPLACE WITH BI-FOLD DOORS AND ADD SHELF AND POLE AT EACH.

7 PATCH EXISTING WALL AS REQUIRED FOR INSTALLATION OF ELECTRICAL PANEL (REFER

TO ELECTRICAL)

8 WALL MOUNTED FIRE EXTINGUISHER -- REFER TO SPECIFICATIONS

9 REFER TO HARDWARE SET 10 IN SPECIFICATION SECTION 08 71 00 FOR CLOSET

HARDWARE

10 24x24 PLYWOOD ACCESS PANEL (PTD) IN DRYWALL CEILING - COORDINATE FINAL

LOCATION WITH WORK IN ATTIC - HEADERS TO MATCH BOTTOM CORD OF ROOF TRUSS -

1x3 WOOD TRIM (PTD) WITH 1/2" FOAM TAPE ALL SIDES

11 DRYWALL CEILING FINISH (PAINTED) MATCH EXISTING CEILING HEIGHT AND TIE INTO

EXISTING BULKHEAD IN LIVING ROOM (01)

12 DRYWALL CEILING FINISH (PAINTED) MATCH EXISTING CEILING SLOPE

A111

SLO

PE

SLO

PE

SLOPE

SLOPE

A111

SL

O

PE

SLOPE

SL

O

PE

RA-2

SLO

PE

SLO

PE

A111

A111

A111

A111

A111

A111

A111

A111

A111

A111

XX-XX 1

SLOPE

XX-XX

TYP.

XX-XX

TYP.

TYP.

RA-1

RA-1

1 ROOF PLAN

A103

2 ROOF ASSEMBLY 1

SCALE: B A103

3 ROOF ASSEMBLY 2

SCALE: B

A1

SCALE: A

SECONDARY ROOFING

UNDERLAYMENT

EXISTING ROOF RAFTER

EXISTING ROOF SHEATHING.

REPLACE DETERIORATED

SHEATHING AS REQ.

1" INSULATION BASE LAYER,

WITH 1/8" TAPERED

INSULATION OVERLAY

SBS MODIFIED BITUMEN

ROOFING SYSTEM

1/2" COVERBOARD

PRIMARY ROOFING

UNDERLAYMENT

STANDING SEAM METAL

ROOFING

SECONDARY ROOFING

UNDERLAYMENT

EXISTING ROOF RAFTER

EXISTING ROOF SHEATHING.

REPLACE DETERIORATED

SHEATHING AS REQ.

PRIMARY ROOFING

UNDERLAYMENT

RA-1 RA-2

1 ROOF VENTILATORS FLASHED INTO STANDING SEAM METAL ROOF -- CENTER IN STANDING

SEAM METAL PANELS -- PROVIDE DIVERTER STRIPS ABOVE VENTILATORS WHEN SPANNING

MULTIPLE PANELS

2 ROOF AND STACK VENTS FLASHED INTO STANDING SEAM METAL ROOF -- REFER TO

PLUMBING DRAWINGS

3 LOW PROFILE ROOF VENTS FLASHED INTO STANDING SEAM METAL ROOF -- CENTER IN

STANDING SEAM METAL PANELS -- REFER TO MECHANCIAL DRAWINGS

A DOCUMENT EXISTING CONDITION OF ROOF RAFTERS AND ROOF SHEATHING AFTER

DEMOLITION OF EXISTING ROOFING MATERIOALS AND PRIOR TO CARRYING OUT NEW

WORK. PROVIDE DOCUMENTATION OF EXISTING CONDITIONS TO CONTRACT OFFICER FOR

REVIEW AND CONFIRMATION OF NEW WORK DESIGN AND APPROACH.

B

ROOF ASSEMLBY RA-2 TO HAVE 1/8-INCH PER FOOT SLOPE WITH TAPERED INSULATION

ON TOP OF 1-INCH BASE LAYER

AREA OF TAPERED INSULATION

ROOF ASSEMBLY TYPE

STANDING SEAM METAL ROOFING

SYSTEM

STANDING SEAM

METAL ROOFING

ROOFING UNDERLAYMENT

32" APA RATED STRUCTURAL

1 SHEATHING

2X8 OVERBUILD

DRILL LINE OF 4" HOLES @ 2'-0"

O.C. FROM EAVE TO RIDGE IN

EACH RAFTER BAY TO PROVIDE

VENTILATION

EXISTING ROOF RAFTER

EXISTING ROOF SHEATHING

MATCH EXISTING SLOPE

NEW 2X8 RAFTER OVERBUILD.

ALIGNED WITH EXISTING RAFTER.

INSECT SCREEN

SBS MODIFIED BITUMEN

ROOFING SYSTEM

2" COVERBOARD

1" INSULATION BASE LAYER,

WITH 18" TAPERED

INSULATION OVERLAY

EXISTING WOOD

ROOF DECK

8" TO 12" SLOPE

SLO

PE

SLO

PE

SLOPE

SLOPE

1 ROOF OVERBUILD FOR FULL EXTENT OF RA-1. INSTALL NEW 2X8 RAFTERS OVER

EXSTING ROOF SHEATHING. ALIGN EACH NEW RAFTER W/EXISTING RAFTER

BELOW. FOR FULL EXTENT OF ROOF ASSEMBLY RA-1 INSTALL 2X8 RAFTER AND

SHEATHING OVERBUILD. TIE NEW RAFTERS TO EXISTING WITH GALVANIZED

METAL TIE PLATE. DRILL GRID OF 4" HOLES AT 2'-0" O.C. IN EXISTING ROOF

SHEATHING ACROSS ENTIRE ROOF AREA TO PROVIDE VENTILATION.

2 REINSTALL EXISTING ROOF VENTILATORS AND FLASHING INTO STANDING SEAM

METAL ROOF

3 ROOF AND STACK VENTS FLASHED INTO STANDING SEAM METAL ROOF -- REFER

TO PLUMBING DRAWINGS

4 LOW PROFILE ROOF VENTS FLASHED INTO STANDING SEAM METAL ROOF --

CENTER IN STANDING SEAM METAL PANELS -- REFER TO MECHANCIAL

DRAWINGS

SL

O

PE

SLOPE

SL

O

PE

SLO

PE

SLO

PE

A DOCUMENT EXISTING CONDITION OF ROOF RAFTERS AND ROOF SHEATHING

AFTER DEMOLITION OF EXISTING ROOFING MATERIOALS AND PRIOR TO

CARRYING OUT NEW WORK. PROVIDE DOCUMENTATION OF EXISTING

CONDITIONS TO CONTRACT OFFICER FOR REVIEW AND CONFIRMATION OF NEW

WORK DESIGN AND APPROACH.

B ROOF ASSEMLBY RA-2 TO HAVE 1/8-INCH PER FOOT SLOPE WITH TAPERED

INSULATION ON TOP OF 1-INCH BASE LAYER

SLOPE

0*>�349*8

G*3*7&1�349*8

1*G*3)

A103 SCALE: B A103 SCALE: B

1/4" = 1' - 0" SCALE OF FEET

0'4' 4' 8'

1 1/2" = 1' - 0" SCALE OF FEET

0'1' 1'6" B

A

A103 SCALE: A

A111

2 ROOF DETAIL - FLAT ROOF EDGE

A111

1 ROOF DETAIL - SLOPED ROOF EAVE

SCALE 1-1/2" = 1' SCALE 1-1/2" = 1'

A111

3 ROOF DETAIL

SCALE 1-1/2" = 1'

2" COVERBOARD

1" INSULATION

MODIFIED BITUMEN

ROOFING SYSTEM

PT WOOD BLOCKING

METAL DRIP EDGE

W/CLEAT

EXISTING ROOF

CONSTRUCTION

PT WOOD BLOCKING

FIBER CEMENT

FASCIA TRIM, 6", PAINTED.

VENTED FIBER CEMENT

SOFFIT PANEL, PAINTED

SECURE INSECT SCREEN

TO TOP SIDE OF SOFFIT

VENT CONTINUOUS

2" COVERBOARD

1" INSULATION

MODIFIED BITUMEN

ROOFING SYSTEM

PT WOOD BLOCKING

METAL DRIP EDGE

W/CLEAT

EXISTING ROOF

CONSTRUCTION

FIBER CEMENT FASCIA

TRIM, PAINTED

32" APA RATED STRUCTURAL

PLYWOOD SHEATHING

STANDING SEAM

METAL ROOF SYSTEM

METAL FLASHING TRIM

W/DRIP EDGE

MODIFIED BITUMEN

ROOFING SYSTEM

2" COVERBOARD

1" INSULATION

EXISTING ROOF DECK

ROOFING UNDERLAYMENT

2X8 RAFTER OVERBUILD, ALIGN

EACH NEW RAFTER W/EXISTING

ROOF RAFTER.

CUT STRIP IN EXISTING ROOF

SHEATHING. DRILL LINE OF 4"

HOLES AT 2'-0" O.C. FROM EAVE

TO RIDGE IN EACH RAFTER BAY

TO PROVIDE VENTILATION.

VENTED FIBER-CEMENT SOFFIT

PANEL. ENSURE CONTINUOUS

PATH OF AIRFLOW FROM SOFFIT

VENT TO RIDGE.

2X8, CONTINUOUS

TIE NEW AND EXISTING RAFTERS

TOGETHER WITH GALVANIZED

METAL SPLICE PLATE AT 4'-0" O.C.

INSECT SCREEN

STANDING SEAM METAL

ROOFING SYSTEM

METAL ROOF PANEL

SYSTEM GABLE-END TRIM

FIBER CEMENT FASCIA

TRIM, 8", PAINTED

ROOF UNDERLAYMENT

32" STRUCTURAL PLYWOOD

2X8 RAFTER OVERBUILD

PT WOOD SHIMS

FIBER CEMENT FASCIA

TRIM, 4", V.I.F

FIBER CEMENT VENTED

SOFFIT PANEL

TIE NEW AND EXISTING

RAFTERS TOGETHER WITH

GALVANIZED METAL SPLICE

PLATE AT 4'-0" O.C.

VENTED RIDGE CAP

STANDING SEAM

METAL ROOF SYSTEM

ROOFING UNDERLAYMENT

33" APA RATED STRUCTURAL 1

SHEATHING

NEW 2X8 RAFTER OVERBUILD,

ALIGNED WITH EXISTING RAFTER

EXISTING RAFTER AND

SHEATHING

TIE NEW AND EXISTING RAFTERS

TOGETHER WITH GALVANIZED

METAL SPLICE PLATE AT 4'-0" O.C.

1 1/2" = 1' - 0" SCALE OF FEET

0'1' 1'6"

11/21/2022

2" COVERBOARD

1" INSULATION

MODIFIED BITUMEN

ROOFING SYSTEM

PT WOOD BLOCKING

METAL DRIP EDGE

W/CLEAT

EXISTING ROOF

CONSTRUCTION

PT WOOD BLOCKING

FIBER CEMENT

FASCIA TRIM, 6", PAINTED.

VENTED FIBER CEMENT

SOFFIT PANEL, PAINTED

SECURE INSECT SCREEN

TO TOP SIDE OF SOFFIT

VENT CONTINUOUS

2" COVERBOARD

1" INSULATION

MODIFIED BITUMEN

ROOFING SYSTEM

PT WOOD BLOCKING

METAL DRIP EDGE

W/CLEAT

EXISTING ROOF

CONSTRUCTION

FIBER CEMENT FASCIA

TRIM, PAINTED

32" APA RATED STRUCTURAL

PLYWOOD SHEATHING

STANDING SEAM

METAL ROOF SYSTEM

METAL FLASHING TRIM

W/DRIP EDGE

MODIFIED BITUMEN

ROOFING SYSTEM

2" COVERBOARD

1" INSULATION

EXISTING ROOF DECK

ROOFING UNDERLAYMENT

2X8 RAFTER OVERBUILD, ALIGN

EACH NEW RAFTER W/EXISTING

ROOF RAFTER.

CUT STRIP IN EXISTING ROOF

SHEATHING. DRILL LINE OF 4"

HOLES AT 2'-0" O.C. FROM EAVE

TO RIDGE IN EACH RAFTER BAY

TO PROVIDE VENTILATION.

VENTED FIBER-CEMENT SOFFIT

PANEL. ENSURE CONTINUOUS

PATH OF AIRFLOW FROM SOFFIT

VENT TO RIDGE.

2X8, CONTINUOUS

TIE NEW AND EXISTING RAFTERS

TOGETHER WITH GALVANIZED

METAL SPLICE PLATE AT 4'-0" O.C.

INSECT SCREEN

STANDING SEAM METAL

ROOFING SYSTEM

METAL ROOF PANEL

SYSTEM GABLE-END TRIM

FIBER CEMENT FASCIA

TRIM, 8", PAINTED

ROOF UNDERLAYMENT

32" STRUCTURAL PLYWOOD

2X8 RAFTER OVERBUILD

PT WOOD SHIMS

FIBER CEMENT FASCIA

TRIM, 4", V.I.F

FIBER CEMENT VENTED

SOFFIT PANEL

TIE NEW AND EXISTING

RAFTERS TOGETHER WITH

GALVANIZED METAL SPLICE

PLATE AT 4'-0" O.C.

VENTED RIDGE CAP

STANDING SEAM

METAL ROOF SYSTEM

ROOFING UNDERLAYMENT

33" APA RATED STRUCTURAL 1

SHEATHING

NEW 2X8 RAFTER OVERBUILD,

ALIGNED WITH EXISTING RAFTER

EXISTING RAFTER AND

SHEATHING

TIE NEW AND EXISTING RAFTERS

TOGETHER WITH GALVANIZED

METAL SPLICE PLATE AT 4'-0" O.C.

1 1/2" = 1' - 0" SCALE OF FEET

0'1' 1'6"

11/21/2022

EXIST PLYWOOD,

REPLACE W/ 23/32" APA

RATED PLYWOOD AS REQ.

NEW ROOFING

UNDERLAYMENT TO

REPLACE EXISTING (GRN)

NEW STANDING SEAM

METAL ROOF SYSTEM

COUNTER FLASHING (GRN)

DRIP EDGE FLASHING (RED)

MODIFIED BITUMEN

ROOFING SYSTEM (BLUE)

1/2" COVER BD

PT WOOD BLOCKING

1" INSULATION TAPER

1/2:12 SLOPE TO EDGE

FIBER CEMENT FACIA

TRIM, PAINTED

EXIST STRUC

SHADED (V.I.F.)

0.5

METAL FLASHING (RED)

MODIFIED BITUMEN

ROOFING SYSTEM (BLUE)

24" BEYOND SLOPE

1/2" COVERBOARD

1" INSULATION TAPER

1/2:12 SLOPE TO EDGE

24"

CAULK SEALANT

SEALANT

2" COVERBOARD

1" INSULATION

MODIFIED BITUMEN

ROOFING SYSTEM

PT WOOD BLOCKING

METAL DRIP EDGE

W/CLEAT

EXISTING ROOF

CONSTRUCTION

PT WOOD BLOCKING

FIBER CEMENT

FASCIA TRIM, 6", PAINTED.

VENTED FIBER CEMENT

SOFFIT PANEL, PAINTED

SECURE INSECT SCREEN

TO TOP SIDE OF SOFFIT

VENT CONTINUOUS

2" COVERBOARD

1" INSULATION

MODIFIED BITUMEN

ROOFING SYSTEM

PT WOOD BLOCKING

METAL DRIP EDGE

W/CLEAT

EXISTING ROOF

CONSTRUCTION

FIBER CEMENT FASCIA

TRIM, PAINTED

32" APA RATED STRUCTURAL

PLYWOOD SHEATHING

STANDING SEAM

METAL ROOF SYSTEM

METAL FLASHING TRIM

W/DRIP EDGE

MODIFIED BITUMEN

ROOFING SYSTEM

2" COVERBOARD

1" INSULATION

EXISTING ROOF DECK

ROOFING UNDERLAYMENT

2X8 RAFTER OVERBUILD, ALIGN

EACH NEW RAFTER W/EXISTING

ROOF RAFTER.

CUT STRIP IN EXISTING ROOF

SHEATHING. DRILL LINE OF 4"

HOLES AT 2'-0" O.C. FROM EAVE

TO RIDGE IN EACH RAFTER BAY

TO PROVIDE VENTILATION.

VENTED FIBER-CEMENT SOFFIT

PANEL. ENSURE CONTINUOUS

PATH OF AIRFLOW FROM SOFFIT

VENT TO RIDGE.

2X8, CONTINUOUS

TIE NEW AND EXISTING RAFTERS

TOGETHER WITH GALVANIZED

METAL SPLICE PLATE AT 4'-0" O.C.

INSECT SCREEN

STANDING SEAM METAL

ROOFING SYSTEM

METAL ROOF PANEL

SYSTEM GABLE-END TRIM

FIBER CEMENT FASCIA

TRIM, 8", PAINTED

ROOF UNDERLAYMENT

32" STRUCTURAL PLYWOOD

2X8 RAFTER OVERBUILD

PT WOOD SHIMS

FIBER CEMENT FASCIA

TRIM, 4", V.I.F

FIBER CEMENT VENTED

SOFFIT PANEL

TIE NEW AND EXISTING

RAFTERS TOGETHER WITH

GALVANIZED METAL SPLICE

PLATE AT 4'-0" O.C.

VENTED RIDGE CAP

STANDING SEAM

METAL ROOF SYSTEM

ROOFING UNDERLAYMENT

33" APA RATED STRUCTURAL 1

SHEATHING

NEW 2X8 RAFTER OVERBUILD,

ALIGNED WITH EXISTING RAFTER

EXISTING RAFTER AND

SHEATHING

TIE NEW AND EXISTING RAFTERS

TOGETHER WITH GALVANIZED

METAL SPLICE PLATE AT 4'-0" O.C.

1 1/2" = 1' - 0" SCALE OF FEET

0'1' 1'6"

11/21/2022

2" COVERBOARD

1" INSULATION

MODIFIED BITUMEN

ROOFING SYSTEM

PT WOOD BLOCKING

METAL DRIP EDGE

W/CLEAT

EXISTING ROOF

CONSTRUCTION

PT WOOD BLOCKING

FIBER CEMENT

FASCIA TRIM, 6", PAINTED.

VENTED FIBER CEMENT

SOFFIT PANEL, PAINTED

SECURE INSECT SCREEN

TO TOP SIDE OF SOFFIT

VENT CONTINUOUS

2" COVERBOARD

1" INSULATION

MODIFIED BITUMEN

ROOFING SYSTEM

PT WOOD BLOCKING

METAL DRIP EDGE

W/CLEAT

EXISTING ROOF

CONSTRUCTION

FIBER CEMENT FASCIA

TRIM, PAINTED

32" APA RATED STRUCTURAL

PLYWOOD SHEATHING

STANDING SEAM

METAL ROOF SYSTEM

METAL FLASHING TRIM

W/DRIP EDGE

MODIFIED BITUMEN

ROOFING SYSTEM

2" COVERBOARD

1" INSULATION

EXISTING ROOF DECK

ROOFING UNDERLAYMENT

2X8 RAFTER OVERBUILD, ALIGN

EACH NEW RAFTER W/EXISTING

ROOF RAFTER.

CUT STRIP IN EXISTING ROOF

SHEATHING. DRILL LINE OF 4"

HOLES AT 2'-0" O.C. FROM EAVE

TO RIDGE IN EACH RAFTER BAY

TO PROVIDE VENTILATION.

VENTED FIBER-CEMENT SOFFIT

PANEL. ENSURE CONTINUOUS

PATH OF AIRFLOW FROM SOFFIT

VENT TO RIDGE.

2X8, CONTINUOUS

TIE NEW AND EXISTING RAFTERS

TOGETHER WITH GALVANIZED

METAL SPLICE PLATE AT 4'-0" O.C.

INSECT SCREEN

STANDING SEAM METAL

ROOFING SYSTEM

METAL ROOF PANEL

SYSTEM GABLE-END TRIM

FIBER CEMENT FASCIA

TRIM, 8", PAINTED

ROOF UNDERLAYMENT

32" STRUCTURAL PLYWOOD

2X8 RAFTER OVERBUILD

PT WOOD SHIMS

FIBER CEMENT FASCIA

TRIM, 4", V.I.F

FIBER CEMENT VENTED

SOFFIT PANEL

TIE NEW AND EXISTING

RAFTERS TOGETHER WITH

GALVANIZED METAL SPLICE

PLATE AT 4'-0" O.C.

VENTED RIDGE CAP

STANDING SEAM

METAL ROOF SYSTEM

ROOFING UNDERLAYMENT

33" APA RATED STRUCTURAL 1

SHEATHING

NEW 2X8 RAFTER OVERBUILD,

ALIGNED WITH EXISTING RAFTER

EXISTING RAFTER AND

SHEATHING

TIE NEW AND EXISTING RAFTERS

TOGETHER WITH GALVANIZED

METAL SPLICE PLATE AT 4'-0" O.C.

1 1/2" = 1' - 0" SCALE OF FEET

0'1' 1'6"

11/21/2022

BEDROOMBEDROOM

HALL

REMOVE EXIST HVAC CHASE &

REFRAME HALLWAY TO HEIGHT

OF TRUSSES.

CLOSE EXIST

OPENINGS ABOVE

DOORS.

5" (R30) CLOSED CELL SPRAY

INSULATION @ UNDERSIDE OF

EXISTING ROOF DECK (TYP)

DUCTWORK, ELECTRICAL, &

SPRINKLER PIPES IN ATTIC

3" (R19) CLOSED CELL SPRAY

INSULATION @ EXTERIOR

WALLS (TYP)

NOTE: PROVIDE SOUND

BATT INSULATION @

BATHROOM WALLS

NOTE: INSTALL CLOSED CELL

INSULATION PRIOR TO ANY

SPRINKLER PIPE INSTALLATION.

PROTECT SPRINKLER PIPES FROM

CONTACT W/ INSULATION.

A111

4 BUILDING SECTION

SCALE 1/2" = 1'

LIVING ROOM

REMOVE EXIST COVE

LIGHTING & CLOSE

OPENING @ CEILING

5" (R30) CLOSED CELL SPRAY

INSULATION @ UNDERSIDE OF

EXISTING ROOF DECK (TYP)

EXIST CATH

CEILING

EXIST

COVE

NOTE: SIMILAR DETAIL @

COVE ON KITCHEN SIDE.

A111

5 BUILDING SECTION AT LIVING ROOM

SCALE 1/2" = 1'

A EXTERIOR PAINTING SCOPE:

▪ ALL EXISTING PAINTED EXTERIOR SURFACES SHALL BE PREPARED AND PAINTED

INCLUDING BUT NOT LIMITED TO CLADDING PANELS, WINDOW TRIM, DOOR

FRAMES, SOFFITS, ROOF OVERHANGS AND ROOF DECKS.

▪ PREPARE ALL SURFACES BY REMOVING EXISTING UNUSED…