This document is a comprehensive set of architectural and engineering drawings for the Orange County Corrections Support Administration Building Window Replacement and Wall Restoration Project, prepared by Jay Ammon Architect, Inc. on July 8, 2022. The project involves a complete exterior renovation of the multi-story corrections administration building, including replacing all windows, curtain walls, and exterior wall surfaces, with work spanning 15 construction phases across four floors and the roof. The project scope includes removing existing hurricane shutters, installing new Level "E" impact-rated windows and curtain walls, restoring brick veneer, repairing precast concrete panels, replacing sealants, refinishing louvers, and conducting comprehensive exterior wall restoration. The estimated project cost is $2,200,000.00, with sealed electronic responses due by 4:00 pm EST on March 9, 2023, through the OpenGov e-Procurement Platform.
The project documents detail extensive technical specifications, including wind load calculations, Florida Building Code 2020 compliance, and specific restoration requirements for various building components. The renovation involves replacing windows with YKK AP storefront and curtain wall systems, applying new wall coatings, resealing control joints, and implementing comprehensive waterproofing and restoration techniques. Specific attention is given to wind resistance, with ultimate wind speed calculations of 145 MPH and risk category III exposure. The phased construction approach is designed to minimize disruption to the occupied corrections administration building, with each phase targeting specific floor areas and rooms, and requiring interior construction barriers and careful coordination with building occupancy.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ORANGE COUNTY CAPITAL PROJECTS DIVISION
PREPARED FOR:
3723 VISION BLVD
ORLANDO, FL 32839
JULY 8, 2022
STATEMENT OF COMPLIANCE
TO THE BEST OF OUR KNOWLEDGE THESE
DRAWINGS ARE COMPLETE AND COMPLY WITH
THE FLORIDA BUILDING CODE 2020 (7TH ED), AND
REFERENCED STATUTES, CODES, RULES AND
REGULATIONS REFERENCED THEREIN.
CONSTRUCTION DOCUMENTS
BOARD OF COUNTY COMMISSIONERS:
DISTRICT 1 - NICOLE H. WILSON
DISTRICT 2 - CHRISTINE MOORE
DISTRICT 3 - MAYRA URIBE
DISTRICT 4 - MARIBEL GOMEZ CORDERO
DISTRICT 5 - EMILY BONILLA
DISTRICT 6 - VICTORIA P. SIPLIN
MAYOR:
JERRY L. DEMINGS
ORANGE COUNTY CORRECTIONS SUPPORT
ADMINISTRATION BUILDING
WINDOW REPLACEMENT & WALL RESTORATION PROJECT
3723 VISION BLVD
ORLANDO, FL 32839
SITE VICINITY MAP
SHEET
REVISIONS
KAK / CAS
APPROVED BY:
DRAWN BY:
JPA
NUMBER TYPE
JULY 8, 2022
PROJECT NUMBER:
DATE:
21-016
DATE:
CONSTRUCTION DOCUMENTS
PLOT:
FAX: (407) 333-4686
126 S. PARK AVE STE. A WINTER PARK, FLORIDA 32789
JAY AMMON ARCHITECT, INC.
(407) 333-1977 E MAIL: JAY@JAYAMMON.COM
ORLANDO, FLORIDA
ORANGE COUNTY GOVERNMENT
WALL RESTORATION PROJECT
ORANGE COUNTY CORRECTIONS
SUPPORT ADMINISTRATION BUILDING
WINDOW REPLACEMENT AND
G1.0N.T.S.
COVER SHEET
AutoCAD SHX Text N
DRAWING INDEX
SHEET
NUMBER SHEET TITLE ORIGINAL
DATE
REVISION
NUMBER
REVISION
DATE
G1.0 COVER SHEET 7/8/2022 0 NA
G1.01 DRAWINGS INDEX 7/8/2022 0 NA
G1.1 SYMBOLS, ABBREVIATIONS AND CODE INFORMATION 7/8/2022 0 NA
G1.2 GENERAL NOTES 7/8/2022 0 NA
G1.3 SCOPE OF WORK 7/8/2022 0 NA
G1.4 OVERALL SITE PLAN
AND AERIAL VIEW
7/8/2022 0 NA
A1.1 EXISTING FIRST FLOOR PLAN 7/8/2022 0 NA
A1.2 EXISTING SECOND FLOOR PLAN 7/8/2022 0 NA
A1.3 EXISTING THIRD FLOOR PLAN 7/8/2022 0 NA
A1.4 EXISTING FOURTH FLOOR PLAN 7/8/2022 0 NA
A1.5 EXISTING ROOF PLAN 7/8/2022 0 NA
A2.0 NORTH AND SOUTH ELEVATIONS 7/8/2022 0 NA
A2.1 EAST AND WEST ELEVATIONS 7/8/2022 0 NA
A2.2
SOUTHEAST AND
NORTHWEST ELEVATIONS
7/8/2022 0 NA
A3.1 WALL SECTIONS 7/8/2022 0 NA
A3.2 WALL SECTIONS 7/8/2022 0 NA
A4.1 STOREFRONT ELEVATIONS 7/8/2022 0 NA
A4.2 CURTAIN WALL ELEVATION 7/8/2022 0 NA
A4.3 CURTAIN WALL ELEVATION 7/8/2022 0 NA
A4.4 STOREFRONT ENTRANCE ELEVATIONS 7/8/2022 0 NA
A5.1 STOREFRONT DETAILS 7/8/2022 0 NA
A5.2 CURTAIN WALL DETAILS 7/8/2022 0 NA
A5.3 DOOR DETAILS 7/8/2022 0 NA
A5.4 DETAILS 7/8/2022 0 NA
A5.5 DETAILS 7/8/2022 0 NA
A5.6 DETAILS 7/8/2022 0 NA
A5.7 DETAILS 7/8/2022 0 NA
A6.1 PHOTOGRAPHS 7/8/2022 0 NA
A6.2 PHOTOGRAPHS 7/8/2022 0 NA
A7.1 CURTAIN WALL & STOREFRONT PRODUCT APPROVALS 7/8/2022 0 NA
A7.2
ENTRANCE DOORS - FLORIDA -
PRODUCT APPROVALS
7/8/2022 0 NA
A8.1 CURTAIN WALL-FLORIDA PRODUCT
APPROVALS-INSTALL INSTRUCTIONS
7/8/2022 0 NA
SHEET
NUMBER SHEET TITLE ORIGINAL
DATE
REVISION
NUMBER
REVISION
DATE
A8.2 CURTAIN WALL-FLORIDA PRODUCT
APPROVALS-INSTALL INSTRUCTIONS
7/8/2022 0 NA
A8.3
CURTAIN WALL-FLORIDA PRODUCT
APPROVALS-INSTALL INSTRUCTIONS
7/8/2022 0 NA
A8.4
CURTAIN WALL-FLORIDA PRODUCT
APPROVALS-INSTALL INSTRUCTIONS
7/8/2022 0 NA
A8.5 CURTAIN WALL-FLORIDA PRODUCT
APPROVALS-INSTALL INSTRUCTIONS
7/8/2022 0 NA
A8.6 CURTAIN WALL-FLORIDA PRODUCT
APPROVALS-INSTALL INSTRUCTIONS
7/8/2022 0 NA
A8.7 CURTAIN WALL-FLORIDA PRODUCT
APPROVALS-INSTALL INSTRUCTIONS
7/8/2022 0 NA
A8.8
CURTAIN WALL-FLORIDA PRODUCT
APPROVALS-INSTALL INSTRUCTIONS
7/8/2022 0 NA
A8.9 CURTAIN WALL-FLORIDA PRODUCT
APPROVALS-INSTALL INSTRUCTIONS
7/8/2022 0 NA
A8.10 STOREFRONT WINDOWS-FLORIDA PRODUCT
APPROVALS-INSTALL INSTRUCTIONS
7/8/2022 0 NA
A8.11
STOREFRONT WINDOWS-FLORIDA PRODUCT
APPROVALS-INSTALL INSTRUCTIONS
7/8/2022 0 NA
A8.12 STOREFRONT WINDOWS-FLORIDA PRODUCT
APPROVALS-INSTALL INSTRUCTIONS
7/8/2022 0 NA
A8.13 STOREFRONT DOORS-FLORIDA PRODUCT
APPROVALS-INSTALL INSTRUCTIONS
7/8/2022 0 NA
A8.14
STOREFRONT DOORS-FLORIDA PRODUCT
APPROVALS-INSTALL INSTRUCTIONS
7/8/2022 0 NA
A8.15
STOREFRONT DOORS-FLORIDA PRODUCT
APPROVALS-INSTALL INSTRUCTIONS
7/8/2022 0 NA
A8.16 STOREFRONT DOORS-FLORIDA PRODUCT
APPROVALS-INSTALL INSTRUCTIONS
7/8/2022 0 NA
A8.20 UL LISTING 7/8/2022 0 NA
A9.0 PHASING SCHEDULE 7/8/2022 0 NA
A9.1 FIRST FLOOR PHASING PLAN 7/8/2022 0 NA
A9.2 SECOND FLOOR PHASING PLAN 7/8/2022 0 NA
A9.3 THIRD FLOOR PHASING PLAN 7/8/2022 0 NA
A9.4 FOURTH FLOOR PHASING PLAN 7/8/2022 0 NA
A9.5 ROOF PHASING PLAN 7/8/2022 0 NA
A9.6 NORTH AND SOUTH ELEVATIONS PROJECT PHASING 7/8/2022 0 NA
A9.7 EAST AND WEST ELEVATIONS PROJECT PHASING 7/8/2022 0 NA
A9.8 SOUTHEAST AND NORTHWEST ELEVATIONS PROJECT
PHASING
7/8/2022 0 NA
S1.1 ROOF WIND PRESSURE PLAN 7/8/2022 0 NA
S1.2 NORTH AND SOUTH WALL WIND PRESSURES 7/8/2022 0 NA
S1.3 EAST AND WEST WALL WIND PRESSURES 7/8/2022 0 NA
S1.4
SOUTHEAST AND NORTHWEST WALL WIND
PRESSURES
7/8/2022 0 NA
SHEET
REVISIONS
KAK / CAS
APPROVED BY:
DRAWN BY:
JPA
NUMBER TYPE
JULY 8, 2022
PROJECT NUMBER:
DATE:
21-016
DATE:
CONSTRUCTION DOCUMENTS
PLOT:
FAX: (407) 333-4686
126 S. PARK AVE STE. A WINTER PARK, FLORIDA 32789
JAY AMMON ARCHITECT, INC.
(407) 333-1977 E MAIL: JAY@JAYAMMON.COM
ORLANDO, FLORIDA
ORANGE COUNTY GOVERNMENT
WALL RESTORATION PROJECT
ORANGE COUNTY CORRECTIONS
SUPPORT ADMINISTRATION BUILDING
WINDOW REPLACEMENT AND
G1.01N.T.S.
DRAWINGS INDEX
CODE INFORMATION
APPLICABLE BUILDING CODES
ARCHITECTURAL ABBREVIATIONS SYMBOLSMATERIALS LEGEND
W1
D1
CW1
SHEET
REVISIONS
KAK / CAS
APPROVED BY:
DRAWN BY:
JPA
NUMBER TYPE
JULY 8, 2022
PROJECT NUMBER:
DATE:
21-016
DATE:
CONSTRUCTION DOCUMENTS
PLOT:
FAX: (407) 333-4686
126 S. PARK AVE STE. A WINTER PARK, FLORIDA 32789
JAY AMMON ARCHITECT, INC.
(407) 333-1977 E MAIL: JAY@JAYAMMON.COM
ORLANDO, FLORIDA
ORANGE COUNTY GOVERNMENT
WALL RESTORATION PROJECT
ORANGE COUNTY CORRECTIONS
SUPPORT ADMINISTRATION BUILDING
WINDOW REPLACEMENT AND
G1.1N.T.S.
SYMBOLS, ABBREVIATIONS
AND CODE INFORMATION
AutoCAD SHX Text
LIGHTWEIGHT CONCRETE
AutoCAD SHX Text
2020 FLORIDA BUILDING CODE - BUILDING
AutoCAD SHX Text
BUILDING :
AutoCAD SHX Text Edition :
AutoCAD SHX Text
SEVENTH
AutoCAD SHX Text Edition :
AutoCAD SHX Text
SEVENTH
AutoCAD SHX Text Edition :
AutoCAD SHX Text Edition :
AutoCAD SHX Text Edition :
AutoCAD SHX Text Edition :
AutoCAD SHX Text Edition :
AutoCAD SHX Text
SEVENTH
AutoCAD SHX Text
SEVENTH
AutoCAD SHX Text
SEVENTH
AutoCAD SHX Text
SEVENTH
AutoCAD SHX Text
SEVENTH
AutoCAD SHX Text Edition :
AutoCAD SHX Text
SEVENTH
AutoCAD SHX Text
2020 FLORIDA BUILDING CODE - EXISTING BUILDING
AutoCAD SHX Text
EXISTING :
AutoCAD SHX Text
2020 FLORIDA BUILDING CODE - MECHANICAL
AutoCAD SHX Text
MECHANICAL :
AutoCAD SHX Text
2020 FLORIDA BUILDING CODE - PLUMBING
AutoCAD SHX Text
PLUMBING :
AutoCAD SHX Text
2020 FLORIDA BUILDING CODE - FUEL GAS
AutoCAD SHX Text
FUEL GAS :
AutoCAD SHX Text
2020 FLORIDA BUILDING CODE - ACCESSIBILITY
AutoCAD SHX Text
ACCESSIBILITY :
AutoCAD SHX Text
2020 FLORIDA BUILDING CODE - ENERGY CONSERVATION
AutoCAD SHX Text
ENERGY :
AutoCAD SHX Text
FLORIDA FIRE PREVENTION CODE (2020)
AutoCAD SHX Text
FIRE :
AutoCAD SHX Text
CONSTRUCTION TYPE: TYPE II 2HR. FIRE PROTECTEDTYPE II 2HR. FIRE PROTECTED
AutoCAD SHX Text
FIRE SPRINKLERS: YESYES
AutoCAD SHX Text OCCUPANCY: CLASSIFICATION: INSTITUTIONAL GROUP - I-3 CONDITION 1CLASSIFICATION: INSTITUTIONAL GROUP - I-3 CONDITION 1
AutoCAD SHX Text
STORIES: 44
AutoCAD SHX Text
BUILDING HEIGHT: 57'-1" TO TOP OF PARAPET57'-1" TO TOP OF PARAPET
AutoCAD SHX Text
PROJECT AREA: ROOF AREA - 20,513 SQ. FT.ROOF AREA - 20,513 SQ. FT.
AutoCAD SHX Text
TOTAL AREA - 80,052 SQ. FT.
AutoCAD SHX Text
C.M.U. ( SECTION )
AutoCAD SHX Text
SHEET ON WHICH
AutoCAD SHX Text
SHEET ON WHICH ELEVATION OCCURS
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
WALL SECTION
AutoCAD SHX Text
ELEVATION
AutoCAD SHX Text
LETTERS FOR DETAILS
AutoCAD SHX Text
SHEET ON WHICH DETAIL OCCURS
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
SECTION OCCURS
AutoCAD SHX Text
OVERALL BUILDING SECTION
AutoCAD SHX Text
SECTION OCCURS
AutoCAD SHX Text
SHEET ON WHICH
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text A
AutoCAD SHX Text A2.1
AutoCAD SHX Text
AutoCAD SHX Text A3.1
AutoCAD SHX Text
AutoCAD SHX Text A4.1
AutoCAD SHX Text
AutoCAD SHX Text A4.1
AutoCAD SHX Text
AutoCAD SHX Text A4.1
AutoCAD SHX Text
NUMBERS FOR FLOOR, ENLARGED UNIT FLOOR PLANS & PHOTOS
AutoCAD SHX Text
EARTH
AutoCAD SHX Text
CONCRETE MASONRY
AutoCAD SHX Text
CONCRETE
AutoCAD SHX Text
COMPRESSIBLE FILLER
AutoCAD SHX Text
PORTLAND CEMENT
AutoCAD SHX Text
PLASTER OVER METAL LATH
AutoCAD SHX Text
UNIT
AutoCAD SHX Text
PORTLAND
AutoCAD SHX Text
BATT INSULATION
AutoCAD SHX Text
ACOUSTICAL TILE
AutoCAD SHX Text
ACOUSTICAL INSULATION
AutoCAD SHX Text
MOTOR CONTROL CENTER
AutoCAD SHX Text
MATERIAL
AutoCAD SHX Text
MODIFIED BITUMINOUS SHEET ROOFING
AutoCAD SHX Text
MAINTENANCE
AutoCAD SHX Text
HOSE BIBB
AutoCAD SHX Text
HOLLOW METAL
AutoCAD SHX Text
INSIDE DIAMETER
AutoCAD SHX Text
HORIZONTAL
AutoCAD SHX Text
HEATING VENTILATING & AIR CONDITIONING
AutoCAD SHX Text
KITCHEN EQUIPMENT CONTRACTOR
AutoCAD SHX Text
MAX
AutoCAD SHX Text
MCC
AutoCAD SHX Text
MBSR
AutoCAD SHX Text
MATL
AutoCAD SHX Text
MAINT
AutoCAD SHX Text
KEC
AutoCAD SHX Text
MAXIMUM
AutoCAD SHX Text
INSUL
AutoCAD SHX Text
ID
AutoCAD SHX Text
HT
AutoCAD SHX Text
HB
AutoCAD SHX Text
HM
AutoCAD SHX Text
HORIZ
AutoCAD SHX Text
INSULATION
AutoCAD SHX Text
MEMBER
AutoCAD SHX Text
FINISH SYSTEM (E.I.F.S.)
AutoCAD SHX Text
PLYWOOD
AutoCAD SHX Text
WOOD BLOCKING
AutoCAD SHX Text
CONTINUOUS WOOD
AutoCAD SHX Text
FINISHED WOOD MEMBER
AutoCAD SHX Text
EXTERIOR INSULATION &
AutoCAD SHX Text
GLASS
AutoCAD SHX Text
GYPSUM BOARD
AutoCAD SHX Text
RIGID INSULATION
AutoCAD SHX Text
METAL
AutoCAD SHX Text
WATER RESISTANT
AutoCAD SHX Text
WORK POINT
AutoCAD SHX Text
WALL COVERING OR WATER CLOSET
AutoCAD SHX Text
WOOD
AutoCAD SHX Text
VINYL COMPOSITION TILE
AutoCAD SHX Text
UPHOLSTERY
AutoCAD SHX Text
TOP OF PARAPET
AutoCAD SHX Text
TOP OF WALL
AutoCAD SHX Text
UNLESS NOTED OTHERWISE
AutoCAD SHX Text
TOP OF STEEL
AutoCAD SHX Text
WD
AutoCAD SHX Text
WR
AutoCAD SHX Text
WP
AutoCAD SHX Text W/
AutoCAD SHX Text W/O
AutoCAD SHX Text
WC
AutoCAD SHX Text W
AutoCAD SHX Text
WITH
AutoCAD SHX Text
WIDE
AutoCAD SHX Text
WITHOUT
AutoCAD SHX Text
VCT
AutoCAD SHX Text
VERT
AutoCAD SHX Text
UPH
AutoCAD SHX Text
UNO
AutoCAD SHX Text
TYP
AutoCAD SHX Text
TOP
AutoCAD SHX Text
TOS
AutoCAD SHX Text
TOW
AutoCAD SHX Text
VERTICAL
AutoCAD SHX Text
TYPICAL
AutoCAD SHX Text
CARPET
AutoCAD SHX Text
CPT
AutoCAD SHX Text
EXPOSED
AutoCAD SHX Text
EXP
AutoCAD SHX Text
GLASS FIBER REINFORCED CONCRETE
AutoCAD SHX Text
FLOOR DRAIN
AutoCAD SHX Text
FINISH FLOOR
AutoCAD SHX Text
FIRE HOSE CABINET
AutoCAD SHX Text
FACE OF CONCRETE
AutoCAD SHX Text
FACE OF FINISH
AutoCAD SHX Text
FACE OF MASONRY
AutoCAD SHX Text
FACE OF STUD
AutoCAD SHX Text
FIBERGLASS REINFORCED PLASTIC
AutoCAD SHX Text FLOOR SINK or FINISH SEALER
AutoCAD SHX Text
GALVANIZED
AutoCAD SHX Text
GLASS FIBER REINFORCED GYPSUM
AutoCAD SHX Text
FOS
AutoCAD SHX Text
GA
AutoCAD SHX Text
GFRG
AutoCAD SHX Text H
AutoCAD SHX Text
GALV
AutoCAD SHX Text
GFRC
AutoCAD SHX Text
FT
AutoCAD SHX Text
FS
AutoCAD SHX Text
FRP
AutoCAD SHX Text
GAUGE
AutoCAD SHX Text
HIGH
AutoCAD SHX Text
FEET
AutoCAD SHX Text
FOF
AutoCAD SHX Text
FOC
AutoCAD SHX Text
FOM
AutoCAD SHX Text
FIN
AutoCAD SHX Text
FLR
AutoCAD SHX Text
FHC
AutoCAD SHX Text
FBR
AutoCAD SHX Text
FD
AutoCAD SHX Text
FF
AutoCAD SHX Text
EXT
AutoCAD SHX Text
FINISH
AutoCAD SHX Text
FLOOR
AutoCAD SHX Text
EXTERIOR
AutoCAD SHX Text
FABRIC
AutoCAD SHX Text
DISTRESSED WOOD PROCESS
AutoCAD SHX Text
CERAMIC TILE
AutoCAD SHX Text
DIAMETER
AutoCAD SHX Text
DOWN SPOUT
AutoCAD SHX Text
DISTRESSED METAL PROCESS
AutoCAD SHX Text
ELECTRICAL DRINKING FOUNTAIN
AutoCAD SHX Text
DIAGONAL
AutoCAD SHX Text
EXTERIOR INSULATION & FINISH SYSTEM
AutoCAD SHX Text
EXPANSION JOINT
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
EQUIPMENT
AutoCAD SHX Text
ELECTRONIC EQUIPMENT ROOM
AutoCAD SHX Text
DS
AutoCAD SHX Text
EER
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
EQUIP
AutoCAD SHX Text
EQ
AutoCAD SHX Text
EIFS
AutoCAD SHX Text
EJ
AutoCAD SHX Text (E)
AutoCAD SHX Text
EA
AutoCAD SHX Text
EDF
AutoCAD SHX Text
EQUAL
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
EACH
AutoCAD SHX Text
DMP
AutoCAD SHX Text
DWP
AutoCAD SHX Text
DN
AutoCAD SHX Text
DIAG
AutoCAD SHX Text
DET
AutoCAD SHX Text
DIA
AutoCAD SHX Text
DBL
AutoCAD SHX Text D
AutoCAD SHX Text
CT
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
DOWN
AutoCAD SHX Text
DEPTH
AutoCAD SHX Text
DOUBLE
AutoCAD SHX Text
ALUMINUM
AutoCAD SHX Text
CONCRETE MASONRY UNIT
AutoCAD SHX Text
ABOVE FINISHED FLOOR
AutoCAD SHX Text AREA DRAIN or AREA DEVELOPMENT
AutoCAD SHX Text ACOUSTICAL CEILING TILE or ACOUSTICAL TREATMENT
AutoCAD SHX Text
AIR CONDITIONING
AutoCAD SHX Text
CONTROL JOINT
AutoCAD SHX Text
CONCRETE
AutoCAD SHX Text
CONTINUOUS
AutoCAD SHX Text
CLG
AutoCAD SHX Text
COL
AutoCAD SHX Text
CONC
AutoCAD SHX Text
CONT
AutoCAD SHX Text
CMU
AutoCAD SHX Text
CLR
AutoCAD SHX Text
CJ
AutoCAD SHX Text
BLDG
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
CLEAR
AutoCAD SHX Text
COLUMN
AutoCAD SHX Text
BUILDING
AutoCAD SHX Text
ALUM
AutoCAD SHX Text
AFF
AutoCAD SHX Text
AD
AutoCAD SHX Text
ACT
AutoCAD SHX Text A/C
AutoCAD SHX Text
OWNER FURNISHED ITEM
AutoCAD SHX Text
OFI
AutoCAD SHX Text
REF
AutoCAD SHX Text
REFERENCE
AutoCAD SHX Text
SANITARY SHEET PLASTIC
AutoCAD SHX Text
TOP OF MASONRY
AutoCAD SHX Text
SURFACED FOUR SIDES
AutoCAD SHX Text
SPECIAL FINISH
AutoCAD SHX Text
RESILIENT FLOOR
AutoCAD SHX Text SQUARE FEET or STONE FACE
AutoCAD SHX Text
ROUGH OPENING
AutoCAD SHX Text
SOLID CORE
AutoCAD SHX Text
STAINLESS STEEL
AutoCAD SHX Text
STANDARD
AutoCAD SHX Text
SUSPENDED
AutoCAD SHX Text
TONGUE AND GROOVE
AutoCAD SHX Text
TELEPHONE
AutoCAD SHX Text TOP OF CONCRETE or CURB
AutoCAD SHX Text
SQUARE
AutoCAD SHX Text
SQ
AutoCAD SHX Text T&G
AutoCAD SHX Text
TOM
AutoCAD SHX Text
TOC
AutoCAD SHX Text
TEL
AutoCAD SHX Text T
AutoCAD SHX Text
STD
AutoCAD SHX Text S4S
AutoCAD SHX Text
SUSP
AutoCAD SHX Text
SSP
AutoCAD SHX Text
SS
AutoCAD SHX Text
TREAD
AutoCAD SHX Text
SPF
AutoCAD SHX Text
SIM
AutoCAD SHX Text
SF
AutoCAD SHX Text
SHT
AutoCAD SHX Text
SC
AutoCAD SHX Text
RO
AutoCAD SHX Text
REQD
AutoCAD SHX Text
RM
AutoCAD SHX Text
RF
AutoCAD SHX Text
SIMILAR
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
REQUIRED
AutoCAD SHX Text
RESILIENT BASE STRAIGHT
AutoCAD SHX Text
REFLECTED CEILING PLAN
AutoCAD SHX Text
RESILIENT BASE COVE
AutoCAD SHX Text
POINT OF SALE
AutoCAD SHX Text
OWNER FURNISHED CONTRACTOR INSTALLED
AutoCAD SHX Text
OWNER FURNISHED OWNER INSTALLED
AutoCAD SHX Text
POINT OF CONNECTION
AutoCAD SHX Text
PLASTIC LAMINATE
AutoCAD SHX Text
PREPARATION
AutoCAD SHX Text
QUARRY TILE
AutoCAD SHX Text
ROOF DRAIN
AutoCAD SHX Text
PREP
AutoCAD SHX Text R or RAD
AutoCAD SHX Text R
AutoCAD SHX Text
RBS
AutoCAD SHX Text
RCP
AutoCAD SHX Text
RD
AutoCAD SHX Text
RBC
AutoCAD SHX Text
QT
AutoCAD SHX Text
RISER
AutoCAD SHX Text
RADIUS
AutoCAD SHX Text
POC
AutoCAD SHX Text
POS
AutoCAD SHX Text
PR
AutoCAD SHX Text
PLYWD
AutoCAD SHX Text
PNT
AutoCAD SHX Text
PLAM
AutoCAD SHX Text
PL
AutoCAD SHX Text
OFOI
AutoCAD SHX Text
OFCI
AutoCAD SHX Text
OPP
AutoCAD SHX Text
PLYWOOD
AutoCAD SHX Text
PAINT
AutoCAD SHX Text
PAIR
AutoCAD SHX Text
PLATE
AutoCAD SHX Text
OPPOSITE
AutoCAD SHX Text
OPERATOR CONTROL PANEL
AutoCAD SHX Text
OPERATOR CONTROL CONSOLE
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text
MEZZANINE
AutoCAD SHX Text
MOISTURE RESISTANT TREATMENT
AutoCAD SHX Text
MISCELLANEOUS
AutoCAD SHX Text
NOT RATED
AutoCAD SHX Text
NOT IN CONTRACT
AutoCAD SHX Text OUTSIDE DIAMETER or OVERFLOW DRAIN
AutoCAD SHX Text
ON CENTER
AutoCAD SHX Text
MRT
AutoCAD SHX Text
OCC
AutoCAD SHX Text
OCP
AutoCAD SHX Text
OD
AutoCAD SHX Text
OC
AutoCAD SHX Text
NIC
AutoCAD SHX Text
NR
AutoCAD SHX Text
MIN
AutoCAD SHX Text
MFR
AutoCAD SHX Text
MISC
AutoCAD SHX Text
MECH
AutoCAD SHX Text
MEZZ
AutoCAD SHX Text
MINIMUM
AutoCAD SHX Text
CEMENT PLASTER
AutoCAD SHX Text
WDF
AutoCAD SHX Text
WOOD FLOOR
AutoCAD SHX Text
STONE
AutoCAD SHX Text
ST
AutoCAD SHX Text
METAL
AutoCAD SHX Text
MET
AutoCAD SHX Text
BRICK FACE
AutoCAD SHX Text
BF
AutoCAD SHX Text
METAL FACE
AutoCAD SHX Text
MF
AutoCAD SHX Text
PF
AutoCAD SHX Text
PLASTER FACE
AutoCAD SHX Text
WOOD FACE
AutoCAD SHX Text
WF
AutoCAD SHX Text
ELEVATION
AutoCAD SHX Text
EL
AutoCAD SHX Text
MASONRY OPENING
AutoCAD SHX Text
MO
AutoCAD SHX Text
ACRYLIC RESIN FLOORING
AutoCAD SHX Text
ARF
AutoCAD SHX Text
BOARD
AutoCAD SHX Text
BD
AutoCAD SHX Text
BO
AutoCAD SHX Text
BOTTOM OF
AutoCAD SHX Text
BOH
AutoCAD SHX Text
BACK OF HOUSE
AutoCAD SHX Text
BOT
AutoCAD SHX Text
BOTTOM
AutoCAD SHX Text
CONTRACTOR FURNISHED OWNER INSTALLED
AutoCAD SHX Text
CFOI
AutoCAD SHX Text
DRAWING
AutoCAD SHX Text
DWG
AutoCAD SHX Text
DRAWER
AutoCAD SHX Text
DWR
AutoCAD SHX Text
EYEHOOK
AutoCAD SHX Text
EH
AutoCAD SHX Text
FOUNDATION
AutoCAD SHX Text
FDN
AutoCAD SHX Text
FINISH FLOOR ELEVATION
AutoCAD SHX Text
FFE
AutoCAD SHX Text
GLASS
AutoCAD SHX Text
GL
AutoCAD SHX Text
GYPSUM BOARD
AutoCAD SHX Text
GYP BD
AutoCAD SHX Text
HIGH POINT
AutoCAD SHX Text
HP
AutoCAD SHX Text
HEIGHT
AutoCAD SHX Text
HVAC
AutoCAD SHX Text
INT
AutoCAD SHX Text
INTERIOR
AutoCAD SHX Text
JT
AutoCAD SHX Text
JOINT
AutoCAD SHX Text
LAVATORY
AutoCAD SHX Text
LAV
AutoCAD SHX Text
LIVE LOAD
AutoCAD SHX Text
LL
AutoCAD SHX Text
NEW
AutoCAD SHX Text (N)
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
NTS
AutoCAD SHX Text
PROJECTION
AutoCAD SHX Text
PROJ
AutoCAD SHX Text
POUNDS PER SQUARE FPPT
AutoCAD SHX Text
PSF
AutoCAD SHX Text
REINFORCED CONCRETE
AutoCAD SHX Text
RC
AutoCAD SHX Text
ROUGH SAWN
AutoCAD SHX Text
RS
AutoCAD SHX Text
STEEL
AutoCAD SHX Text
STL
AutoCAD SHX Text
STRUCTURAL
AutoCAD SHX Text
STRUCT
AutoCAD SHX Text
VIF
AutoCAD SHX Text
VERIFY IN FIELD
AutoCAD SHX Text
WOOD BASE
AutoCAD SHX Text
WDB
AutoCAD SHX Text
APPROX
AutoCAD SHX Text
APPROXIMATELY
AutoCAD SHX Text
AIR HANDLING UNIT
AutoCAD SHX Text
AHU
AutoCAD SHX Text
CLEAN OUT
AutoCAD SHX Text
CO
AutoCAD SHX Text
DEAD LOAD
AutoCAD SHX Text
DL
AutoCAD SHX Text
FMG
AutoCAD SHX Text
FACTORY MUTUAL GLOBAL
AutoCAD SHX Text
FRT
AutoCAD SHX Text
FIRE RETARDANT TREATED
AutoCAD SHX Text
NATIONAL ROOFING CONTRACTORS ASSOCIATION
AutoCAD SHX Text
NRCA
AutoCAD SHX Text P.S.I.
AutoCAD SHX Text
POUNDS PER SQUARE INCH
AutoCAD SHX Text
PRESSURE TREATED
AutoCAD SHX Text
PT
AutoCAD SHX Text
SQUARE FEET OR SQUARE FOOT
AutoCAD SHX Text
SQ FT
AutoCAD SHX Text
SOUTHERN YELLOW PINE
AutoCAD SHX Text
SYP
AutoCAD SHX Text
GALLON
AutoCAD SHX Text
GAL
AutoCAD SHX Text
HOUR
AutoCAD SHX Text
HR
AutoCAD SHX Text
KILN DRIED AFTER TREATMENT
AutoCAD SHX Text
KDAT
AutoCAD SHX Text
LOW POINT
AutoCAD SHX Text
LP
AutoCAD SHX Text
UL
AutoCAD SHX Text
UNDERWRITERS LABORATORIES INC.
AutoCAD SHX Text
KD
AutoCAD SHX Text
KILN DRIED
AutoCAD SHX Text
DENS DECK SHEATHING
AutoCAD SHX Text
WINDOW / STOREFRONT TYPE SYMBOL
AutoCAD SHX Text
CURTAIN WALL TYPES SYMBOLS
AutoCAD SHX Text
TAPERED INSULATION
AutoCAD SHX Text
COVER BOARD
AutoCAD SHX Text
BRICK
AutoCAD SHX Text
EXTERIOR SHEATHING
AutoCAD SHX Text
DOOR TYPE SYMBOL
AutoCAD SHX Text
DOOR TYPES SYMBOLS
AutoCAD SHX Text
CURTAIN WALL SYMBOL
CURTAIN WALL TYPES SYMBOL
GENERAL NOTES:
A. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE FIELD. THIS
SHALL INCLUDE VERIFYING THE EXACT LOCATIONS, DIMENSIONS AND
QUANTITIES OF ALL WALL MOUNTED EQUIPMENT AND PENETRATIONS WHICH
INCLUDES, BUT IS NOT LIMITED TO VENT PIPES, DRAINS, ELECTRICAL JUNCTION
BOXES, CURBS, BASE FLASHING AND ALL OTHERS PENETRATIONS AND WORK
ASSOCIATED WITH THIS EXTERIOR RESTORATION PROJECT. THE CONTRACTOR
SHALL NOTIFY THE ARCHITECT, IN WRITING, OF ALL EXISTING CONDITIONS
WHICH ARE IN VARIANCE WITH THE CONDITIONS DOCUMENTED HEREIN.
B. CONTRACTOR SHALL PROTECT ALL EXISTING CONSTRUCTION TO REMAIN,
INCLUDING ADJACENT ROOFS, WALLS, LANDSCAPE/VEGETATION, GROUNDS,
EXTERIOR SURFACES AND THE INTERIOR OF THE BUILDING. THIS SHALL
INCLUDE, BUT IS NOT LIMITED TO PAINT, WATER, DUST, DEBRIS AND PHYSICAL
DAMAGE. ALL SURFACES SHALL BE RESTORED TO THEIR PRE-DAMAGE
CONDITION BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER
AND TO THE SATISFACTION OF THE OWNER AND ARCHITECT.
C. ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL CODES
AND AUTHORITIES HAVING JURISDICTION OVER THIS PROJECT.
D. ALL DETAILS INDICATE MINIMUM INSTALLATION REQUIREMENTS. IF THE
MANUFACTURER'S STANDARDS DETAILS ARE MORE STRINGENT, IN THE OPINION
OF THE ARCHITECT, THEY SHALL GOVERN. IF THE DETAILS SHOWN ARE MORE
STRINGENT THAN THE MANUFACTURER'S STANDARD DETAILS, IN THE OPINION
OF THE ARCHITECT, THE DETAILS SHOWN SHALL GOVERN, REGARDLESS OF THE
MANUFACTURER'S WILLINGNESS TO WARRANT / GUARANTY THE LESSER
DETAIL. BY SUBMITTING A BID FOR THIS PROJECT, IT IS UNDERSTOOD THAT THE
CONTRACTOR AND MANUFACTURER AGREE TO WARRANT / GUARANTY THE
DETAILS SHOWN. THE ARCHITECT MAY, BUT IS NOT OBLIGATED TO, ACCEPT ANY
PROPOSED CHANGES TO THE DETAILS SHOWN.
E. THE CONTRACTOR IS TO PROVIDE ALL LABOR AND MATERIAL FOR A COMPLETE
AND WATERTIGHT JOB WHICH IS FULLY WARRANTED / GUARANTEED BY THE
MANUFACTURER AS PROVIDED FOR IN THE CONTRACT DOCUMENTS. ANY
DETAILS OR WORK REQUIRED FOR A COMPLETE JOB, BUT NOT SHOWN OR
SPECIFIED BY THE CONTRACT DOCUMENTS, SHALL BE INSTALLED IN
ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATIONS AND
REQUIREMENTS AT NO ADDITIONAL COST TO THE OWNER. ANY ADDITIONAL
LABOR AND MATERIAL REQUIRED TO MEET MANUFACTURER'S WARRANTY /
GUARANTY REQUIREMENTS, BUT NOT INDICATED BY THE CONTRACT
DOCUMENTS, SHALL BE PROVIDED AT NO ADDITIONAL COST TO THE OWNER.
F. ALL REFINISHING REQUIREMENTS, SHALL INCLUDE THE FOLLOWING:
REMOVE ALL RUST FROM METAL SURFACES AND APPLY COAT OF RUST
INHIBITOR. REPLACE ALL METAL COMPONENTS WHICH ARE CORRODED
THROUGH THE METAL. PRESSURE CLEAN ALL EXPOSED SURFACES. SECURE
ALL LOOSE COMPONENTS WITH STAINLESS STEEL FASTENERS WHICH EXTEND
INTO SOLID SUBSTRATE BELOW OR BEHIND COMPONENT BEING SECURED.
CONCEAL FASTENER HEADS WITH MATERIAL WHICH MATCHES ADJACENT
SURFACES. REPAINT ALL EXPOSED SURFACES TO MATCH EXISTING FINISHES.
G. LAYDOWN/STORAGE AREA IS LIMITED AND SHALL BE AS APPROVED BY THE
OWNER.
H. PRIOR TO PERFORMING WORK, CONTRACTOR SHALL INSPECT WORK SITE AND
EXISTING CONSTRUCTION FOR POTENTIAL SAFETY HAZARDS. PROVIDE FOR THE
SAFETY AND PROTECTION OF WORKERS AND OCCUPANTS THROUGHOUT
COURSE OF WORK. COMPLY WITH OSHA REQUIREMENTS.
I. BUILDING ACCESS IS RESTRICTED AND ALLOWED ONLY AS REQUIRED TO
ACCOMPLISH CONTRACT WORK. COORDINATE ANY REQUIRED ACCESS WITH
THE OWNER.
J. SITE SHALL BE CLEANED AND SECURED ON A DAILY BASIS AT THE END OF EACH
WORK SHIFT.
K. ALL COMPONENTS AND ASSEMBLIES SHALL MEET OR EXCEED UL STANDARDS
FOR A CLASS A FIRE RATING.
L. THE FINISH OF ALL NEW COMPONENTS OR REPAIRED COMPONENTS SHALL
MATCH ALL CHARACTERISTICS OF THE EXISTING COMPONENTS INCLUDING
TEXTURE AND ALL OTHER QUALITIES.
M. PATCH ALL FINISHES AFFECTED BY THE WORK OF THIS PROJECT AS REQUIRED
TO MATCH ALL CHARACTERISTICS OF EXISTING UNDAMAGED FINISHES.
N. ALL ITEMS IN DRAWINGS ARE NEW UNLESS DEPICTED/NOTED AS "EXISTING".
GENERAL SCOPE OF WORK:
A. SEE SHEET G1.3 FOR DESCRIPTION OF WORK.
BUILDING PROTECTION NOTES:
A. THE BUILDING WILL REMAIN FUNCTIONAL THROUGHOUT THE CONSTRUCTION
PERIOD. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO CONTENTS
AND OCCUPANTS. CONTRACT TO COORDINATE WITH OWNERSHIP REGARDING
PROTECTION, REQUIRED ACCESSIBILITY AND NECESSARY LINES OF SITE.
B. THE BUILDING SHALL BE WATERTIGHT AT THE END OF EACH DAYS CONSTRUCTION
AND WHEN INCLEMENT WEATHER THREATENS.
C. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PROTECT ALL
EXISTING CONSTRUCTION TO REMAIN, INCLUDING THE BUILDING, ADJACENT ROOFS,
WALLS, LANDSCAPE/VEGETATION, GROUNDS, EXTERIOR SURFACES, THE INTERIOR OF
THE BUILDING AND ALL PROMENADE CONCRETE WITHIN THE PROJECT BOUNDARIES.
THIE SHALL INCLUDE BUT NOT LIMITED TO PAINT, WATER, DUST, DEBRIS AND
PHYSICAL DAMAGE. ALL SURFACES SHALL BE RESTORED TO THEIR PRE-DAMAGED
CONDITION BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER AND TO
THE SATISFACTION OF THE OWNER AND ARCHITECT. OVERHEAD PROTECTION
BRIDGE TO BE INSTALLED OVER ALL PUBLIC WALKWAYS.
D. ANY SURFACES STAINED, MARKED, MARRED, OR DAMAGED BY THE CONTRACTOR
SHALL BE RETURNED TO THE ORIGINAL CONDITION AND TO MATCH ADJACENT
SURFACES.
E. LAYDOWN/STORAGE AREA IS LIMITED AND SHALL BE APPROVED BY THE OWNER.
F. PRIOR TO PERFORMING WORK, CONTRACTOR SHALL INSPECT WORK SITE AND
EXISTING CONSTRUCTION FOR POTENTIAL SAFETY HAZARDS. PROVIDE FOR THE
SAFETY AND PROTECTION OF WORKERS AND OCCUPANTS THROUGHOUT COURSE
OF WORK. COMPLY WITH OSHA REQUIREMENTS.
G. BUILDING ACCESS IS RESTRICTED AND ALLOWED ONLY AS REQUIRED TO
ACCOMPLISH CONTRACT WORK. COORDINATE ANY REQUIRED ACCESS WITH THE
OWNER.
EXTERIOR RESTORATION NOTES:
A. FOR PURPOSES OF THIS PROJECT, REMOVE SHALL MEAN REMOVE AND DISPOSE OF
IN AN APPROVED AND LEGAL MANNER.
B. CONTRACTOR SHALL VERIFY THE TOTAL NUMBER OF DETAIL CONDITIONS IN THE
FIELD AND PERFORM NEW WORK IN ACCORDANCE WITH THE DETAIL REFERENCED
OR THOSE WHICH ARE SIMILAR. CONTRACTOR SHALL VERIFY ALL CONDITIONS IN THE
FIELD.
C. DAMAGED OR DETERIORATED WALL SUBSTRATE UNCOVERED DURING DEMOLITION
SHALL BE DOCUMENTED BY THE CONTRACTOR, REPORTED TO THE PROJECT
MANAGER IN WRITING.
D. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL EXISTING WALL MATERIALS
AND METHODS OF INSTALLATION BEFORE THE START OF WORK. ANY DISCREPANCIES
BETWEEN THE INFORMATION PROVIDED BY THE CONTRACT DOCUMENTS AND
CONDITIONS ENCOUNTERED BY THE CONTRACTOR BEFORE THE START OF WORK
SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE OWNER. THE
CONTRACTOR SHALL NOT BE ENTITLED TO COMPENSATION FOR ANY ADDITIONAL
LABOR OR MATERIALS DUE TO DIFFERING EXISTING CONDITIONS WHICH ARE NOT
BROUGHT TO THE ATTENTION OF THE OWNER PRIOR TO THE START OF WORK.
E. THE CONTRACTOR SHALL REMOVE ALL EXISTING EXTERIOR CONDUIT, PIPING,
LIGHTING FIXTURES, LIGHTNING PROTECTION SYSTEMS AND ANY OTHER ITEMS
WHICH INTERFERE WITH THE INSTALLATION OF THE NEW EXTERIOR BUILDING
ENVELOPE COMPONENTS AND OR RELATED WORK. ALL SUCH EQUIPMENT AND ITEMS
SHALL BE TEMPORARILY RE-ROUTED AS NECESSARY IF IT IS REQUIRED TO STAY IN
SERVICE. ANY ITEMS NOT REQUIRED TO STAY IN SERVICE SHALL BE PROPERLY
STORED BY THE CONTRACTOR AND REINSTALLED AT THE COMPLETION OF THE
WORK. ALL WORK SHALL BE PERFORMED BY QUALIFIED, LICENSED CRAFTSMEN IN
ACCORDANCE WITH ALL APPLICABLE BUILDING CODES AT NO ADDITIONAL COST TO
THE OWNER. ANY EXISTING WORK WHICH DOES NOT CONFORM TO APPLICABLE
CURRENT CODES SHALL BE REPORTED TO THE OWNER IN WRITING PRIOR TO THE
REMOVAL.
SPECIFIC NOTES:
A. PERFORMANCE REQUIREMENTS: THE CONTRACTOR SHALL BASE THE BID UPON PROVIDING A
COMPLETE EXTERIOR RESTORATION PROJECT AS REQUIRED TO PROVIDE ASSEMBLIES WHICH WILL REMAIN WATERTIGHT FOR A MINIMUM PERIOD OF 20 YEARS. THE CONTRACTOR SHALL ADVISE THE ARCHITECT OF ANY DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND THE CONSTRUCTION
DOCUMENTS, PRIOR TO SUBMISSION OF THE BID.
B. EXISTING CONDITIONS VERIFICATION: THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING
CONDITIONS, INCLUDING BUT NOT LIMITED TO, WINDOW AND DOOR OPENINGS AND EXISTING
EXTERIOR WALL ASSEMBLY MATERIALS AND DETAILS.
C. COMPLIANCE WITH INDUSTRY STANDARDS: ALL WORK SHALL BE PERFORMED IN
ACCORDANCE WITH THE CONSTRUCTION DOCUMENT REQUIREMENTS, MANUFACTURER'S
RECOMMENDATIONS, BUILDING CODE REQUIREMENTS, AND RECOGNIZED INDUSTRY STANDARDS,
INCLUDING BUT NOT LIMITED TO, THE AAMA, AND NAFS WINDOW STANDARDS.
D. WIND RESISTANCE: ALL NEW EXTERIOR COMPONENTS SHALL BE INSTALLED TO RESIST FORCES RESULTING FROM AN ULTIMATE DESIGN WIND SPEED OF 150 MPH IN ACCORDANCE WITH ASCE 7-16.
SUBMIT ENGINEERING CALCULATIONS PREPARED BY A FLORIDA LICENSED STRUCTURAL ENGINEER
TO VERIFY COMPLIANCE WITH THIS REQUIREMENT FOR EACH NEW COMPONENT.
E. TYPICAL NOTES, SECTIONS AND DETAILS: NOTES, SECTIONS, AND DETAILS DESCRIBING
REQUIRED WORK AT EACH COMPONENT ARE TYPICAL FOR ALL SIMILAR COMPONENTS AND THE
NOTE, SECTION, OR DETAIL SHALL APPLY AS IF CALLED OUT SEPARATELY AT EACH LOCATION. THE
DETAILS REFLECT A GENERAL DESIGN OF EACH DETAIL. THE CONTRACTOR SHALL MAKE ANY
REQUIRED MODIFICATIONS TO THE GIVEN DETAILS NECESSARY TO MAKE THE DETAIL COMPATIBLE WITH EXISTING CONDITIONS. THE CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ARCHITECT
FOR ALL MODIFIED DETAILS BEFORE THE DETAILS ARE CONSTRUCTED.
F. PATCHING: PATCH ALL EXISTING COMPONENTS THAT ARE AFFECTED BY THE CONSTRUCTION
WORK OF THIS PROJECT WHETHER OR NOT IDENTIFIED BY THE CONSTRUCTION DOCUMENTS TO BE PATCHED. PATCHING IS DEFINED AS: REPAIRING ALL EXISTING COMPONENTS INCLUDING BUT NOT LIMITED TO SUBSTRATE MATERIALS, STRUCTURAL COMPONENTS, AND FINISHES IN ACCORDANCE WITH INDUSTRY STANDARDS. ALL FINISHES AFFECTED BY THE CONSTRUCTION SHALL BE PATCHED TO MATCH ALL CHARACTERISTICS OF EXISTING ADJACENT MATERIALS INCLUDING BUT NOT LIMITED
TO MATERIAL TYPE, FINISH TEXTURE, AND COLOR OF FINISH.
G. MOCKUPS: PREPARE ONE IN-PLACE MOCKUP OF EACH NEW COMPONENT TYPE. RECEIVE WRITTEN APPROVAL FROM ALL MATERIAL MANUFACTURERS FOR PRODUCTS INCLUDED IN THE MOCKUP, FROM
THE ARCHITECT, AND FROM THE OWNER PRIOR TO FURTHER APPLICATION OR INSTALLATION.
H. TESTING: CONDUCT APPROPRIATE TESTS FOR EACH NEWLY INSTALLED COMPONENT.
I. NEW COMPONENTS: ALL DEPICTED COMPONENTS ON DRAWINGS ARE NEW UNLESS IDENTIFIED
AS EXISTING.
J. INTERIOR PROTECTION: PRIOR TO DEMOLITION, INSTALL PROTECTION OVER INTERIOR SPACES
AS REQUIRED TO PROTECT OCCUPANTS, BUILDING COMPONENTS, AND EQUIPMENT FROM WEATHER
ELEMENTS AND CONSTRUCTION RELATED DEBRIS. COORDINATE PER PHASING PLAN AND
OWNERSHIP REQUIREMENTS TO MAINTAIN MEANS OF EGRESS.
K. HOUSEKEEPING: THOROUGHLY CLEAN ALL CONSTRUCTION RELATED DEBRIS FROM ALL INTERIOR SURFACES, EXTERIOR SURFACES, AND SITE SURFACES ON A DAILY BASIS. ALL CONSTRUCTION EQUIPMENT, DEBRIS, AND NEW MATERIAL STORED ON THE SITE SHALL BE SECURED TO PREVENT
WIND DISPLACEMENT.
L. SAFETY: PROVIDE ALL NECESSARY MEASURES TO ENSURE SAFETY TO BUILDING OCCUPANTS
DURING THE PERIODS WHEN THE BUILDING IS OCCUPIED. PREVENT ACCESS TO THE CONSTRUCTION AREAS AND STAGING AREAS BY SIGNS, FENCES, AND OTHER BARRIERS. INSTALL A TEMPORARY BARRIER OVER THE TOP OF ALL ENTRANCES FOR A DISTANCE OF 10 FEET BEYOND THE ENTRANCE AS
REQUIRED TO PROTECT PEDESTRIANS FROM FALLING DEBRIS.
M. TRADES: ALL WORK SHALL BE PERFORMED BY CONTRACTORS LICENSED IN THEIR TRADES AND AS REQUIRED BY THE BUILDING DEPARTMENT OFFICIALS. THESE TRADES INCLUDE BUT ARE NOT LIMITED
TO WINDOW CONTRACTORS, GENERAL CONTRACTORS, ELECTRICAL CONTRACTORS, HVAC
CONTRACTORS, PLUMBING CONTRACTORS, AND SEALANT CONTRACTORS.
N. OVERHEAD PROTECTION: PROVIDE OVERHEAD PROTECTION AT PUBLIC WALKWAYS WHILE WORK IS TO BE COMPLETED ABOVE. THIS IS TO BE INCLUDE ANY AREAS THAT CAN NOT BE CLOSED TO THE
PUBLIC DURING CONSTRUCTION.
SHEET
REVISIONS
KAK / CAS
APPROVED BY:
DRAWN BY:
JPA
NUMBER TYPE
JULY 8, 2022
PROJECT NUMBER:
DATE:
21-016
DATE:
CONSTRUCTION DOCUMENTS
PLOT:
FAX: (407) 333-4686
126 S. PARK AVE STE. A WINTER PARK, FLORIDA 32789
JAY AMMON ARCHITECT, INC.
(407) 333-1977 E MAIL: JAY@JAYAMMON.COM
ORLANDO, FLORIDA
ORANGE COUNTY GOVERNMENT
WALL RESTORATION PROJECT
ORANGE COUNTY CORRECTIONS
SUPPORT ADMINISTRATION BUILDING
WINDOW REPLACEMENT AND
G1.2N.T.S.
GENERAL NOTES
SCOPE OF WORK:
0.1 GENERAL: THE WINDOW REPLACEMENT AND EXTERIOR WALL REPAIR PROJECT OF THE
ORANGE COUNTY CORRECTIONS ADMINISTRATION BUILDING INCLUDES THE REPLACEMENT OF
ALL WINDOWS AND THE RESTORATION OF ALL EXTERIOR WALL SURFACES EXPOSED TO THE
WEATHER. AT A MINIMUM, ALL EXTERIOR ENVELOPE PREVIOUSLY PAINTED SURFACES WILL BE
PROPERLY PREPARED, PRIMED, PAINTED, AND ALL EXPOSED SEALANTS TO BE REPLACED. ALL
BRICK VENEER WILL BE RESTORED AND BE SEALED. ALL CURTAIN WALL COMPONENTS ARE TO
BE REMOVED AND REPLACED. CONTRACTOR TO INSURE ALL CODE REQUIRED INSPECTION ARE
COORDINATED. WHERE A SCOPE OF WORK ITEM IS DESIGNATED, THAT DESIGNATION IS TYPICAL
FOR ALL SIMILAR COMPONENTS AND ASSEMBLIES WHETHER OR NOT SPECIFICALLY
DENOTED/CALLED OUT IN THE DRAWINGS.
1.0 EXTERIOR WINDOWS AND CURTAIN WALLS:
1.1 HURRICANE SHUTTER REMOVAL: REMOVE ALL EXISTING HURRICANE SHUTTER
COMPONENTS FROM THE ROOF AND WALL ASSEMBLY INCLUDING BUT NOT LIMITED TO; ROOF
HOUSING STRUCTURE, WALL MOUNTED HOUSING, HURRICANE SCREENS, MECHANICAL
COMPONENTS, TRACKS, FASTENERS, FRAMING AND ACCESSORIES. HURRICANE SHUTTERS ARE
LOCATED AT CURTAIN WALL AND STOREFRONT WINDOW ASSEMBLIES. CUT ALL WALL ANCHORS
BACK AND GRIND DOWN 1" RECESSED FROM FACE OF WALL SURFACE. INSTALL EPOXY GROUT
PER MANUFACTURER'S SPECIFICATIONS. AT THE ROOF LEVEL, CUT EXISTING SUPPORT POSTS
DOWN FLUSH WITH THE EXISTING INSULATION. FILL POSTS WITH POLYISOCYANURATE
INSULATION AND INSTALL COVER BOARD. PREP SURFACE AND INSTALL ROOF PATCH WITH
MODIFIED BITUMEN BASE SHEET, CAP SHEET AND TWO PART REINFORCED PMMA LIQUID APPLIED
MEMBRANE. PATCH TO BE PER EXISTING ROOFING MANUFACTURER'S SPECIFICATIONS AND
COMPLY WITH THE EXISTING WARRANTY REQUIREMENTS. SEE DETAIL C/A5.4
1.2 ENGINEERING AND MOCK-UPS: CONTRACTOR TO PROVIDE SEALED ENGINEERED SHOP
DRAWINGS OF THE NEW CURTAIN WALL, STOREFRONT WINDOW ASSEMBLIES, CAST-IN-PLACE
CONCRETE CURBS, STOREFRONT DOOR ASSEMBLIES, FASCIA PANELS, AND NEW ALUMINUM
TUBE / BENT PLATE WINDOW FRAMING COMPLYING WITH PROJECT WIND UPLIFT PRESSURES AND
TESTED WINDOW FPA CRITERIA. ENGINEERED SHOP DRAWINGS TO BE COMPLETED BY A STATE
OF FLORIDA LICENSED STRUCTURAL ENGINEER. INSTALL IN-FIELD MOCK-UPS OF CURTAIN WALL
FLASHINGS, WINDOW FLASHINGS AND WINDOW FRAMING FOR OWNER AND ARCHITECT
APPROVAL.
1.3 EXTERIOR WINDOWS:
1.3.1 EXTERIOR WINDOWS AT PRECAST CONCRETE PANELS: REMOVE EXISTING
WINDOW ASSEMBLY AND ACCESSORIES AT THE EXISTING WINDOWS AT PRECAST CONCRETE
PANELS. AT EXISTING WINDOW OPENINGS, PRIME SURFACES AND INSTALL A LAYER OF GRACE
PERM-A-BARRIER HIGH TEMPERATURE SELF ADHERED WATERPROOFING MEMBRANE TO TIE-IN
EXISTING INTERNAL WALL WATERPROOFING WITH THE NEW WINDOW ASSEMBLY COMPONENTS.
INSTALL NEW .050" ALUMINUM WINDOW SILL PAN WITH END DAMS, JAMB AND TRIM FLASHINGS BY
WINDOW MANUFACTURER. TURN UP BACKS AND SIDES OF SILL TRIM. INSTALL LAYER OF SELF
ADHERED MEMBRANE WITHIN SILL PAN. INSTALL NEW FIXED ALUMINUM LEVEL "E" RATED
HURRICANE IMPACT STOREFRONT WINDOWS. BASIS OF DESIGN: YKK (MODEL YHS 50 FI)
COMPLYING WITH FPA: 14218.1. ALL GLASS FINISH/TINT TO BE SELECTED BY OWNERSHIP FROM STANDARD LEVEL "E" GLAZING MEETING FBC SHGC REQUIREMENTS. SEAL ALL FASTENER HEADS
WITH A BEAD OF SEALANT PER MANUFACTURER'S SPECIFICATIONS. MATCH ALL EXISTING
WINDOW FRAMING PROFILES. INSTALL BACK PLATE ON WINDOW FRAME AND INSTALL A DOUBLE
BEAD OF SEALANT AT THE PERIMETER OF THE EXTERIOR WINDOWS MATCHING COLOR OF
WINDOW FRAME. WINDOW FRAME COLOR TO BE DARK BRONZE ANODIZED ALUMINUM. SEAL ALL
INTERIOR WINDOW JOINTS WITH LATEX SEALANT. SEE SPECIFICATION 08 43 13.
1.3.2 EXTERIOR WINDOWS AT BRICK CAVITY WALL: AT THE 1ST FLOOR BRICK CAVITY
WALL, REMOVE AND DISPOSE OF THE EXISTING WINDOW. NOTCH EXPOSED INSULATION TO
CONNECT EXISTING WATERPROOFING TO NEW AIR BARRIER. INSTALL NEW 22 GAUGE METAL TRIM ANGLE SET IN SEALANT AT JAMBS. FASTEN AT INTERIOR JAMB FACE AND SET IN BUTYL TAPE.
INSTALL SELF ADHERED WATERPROOFING AT WINDOW SILL WITH END DAMS. AT EXISTING
WINDOW OPENINGS, INSTALL NEW .050" ALUMINUM WINDOW SILL PAN WITH END DAMS. TURN UP
BACKS AND SIDES OF SILL TRIM. FILL JAMB CAVITY BETWEEN BRICK AND BACK-UP MASONRY
WITH NON-SHRINK GROUT. INSTALL NEW FIXED ALUMINUM LEVEL "E" RATED HURRICANE IMPACT
STOREFRONT WINDOWS. BASIS OF DESIGN: YKK (MODEL YHS 50 FI) COMPLYING WITH FPA:
14218.5. GLAZING TO MATCH EXISTING MIRRORED FINISH MEETING REQUIRED SHGC PER FBC.
SEAL ALL FASTENER HEADS WITH A BEAD OF SEALANT. MATCH ALL EXISTING WINDOW FRAMING
PROFILES. INSTALL BACK PLATE ON WINDOW FRAME AND INSTALL DOUBLE BEAD OF SEALANT
AT THE PERIMETER OF THE EXTERIOR WINDOWS MATCHING COLOR OF WINDOW FRAME.
WINDOW FRAME COLOR TO BE DARK BRONZE ANODIZED ALUMINUM. SEAL ALL INTERIOR
WINDOW JOINTS WITH LATEX SEALANT. SEE SPECIFICATION 08 43 13.
1.4 WINDOW GLAZING: INSTALL LEVEL "E" MISSILE TESTED GLAZING PER FPA. COLOR TO
MATCH EXISTING WINDOW ASSEMBLIES SELECTED BY OWNERSHIP FROM STANDARD COLOR
SELECTION MEETING FBC REQUIREMENTS. SEE SPECIFICATION SECTION 08 80 00.
1.5 CURTAIN WALL ASSEMBLIES: REMOVE EXISTING CURTAIN WALL ASSEMBLY AND
DISPOSE OF IT PER PROJECT REQUIREMENTS. REMOVE AND REPLACE METAL CLOSURES AT THE
JAMBS. BASIS OF DESIGN: ALUCOBOND PLUS PANELS. PANEL FINISH TO BE SELECTED FROM BY
OWNER FROM STANDARD COLORS. AT EXPOSED CURTAIN WALL OPENINGS, INSTALL 1
2" EXTERIOR
WALL BOARD TO EXPOSED FRAMING. INSTALL .063 ALUMINUM CLOSURE BETWEEN NEW CURTAIN
WALL AND WALL CLOSURE. SEE SPECIFICATION SECTION 07 42 13 PRIME AND INSTALL A LAYER
OF SELF ADHERED WATERPROOFING MEMBRANE TO TIE-IN EXISTING INTERNAL WALL
WATERPROOFING WITH NEW CURTAIN WALL COMPONENTS AND FRAMING. INSTALL CONTINUOUS
INSULATION ON EXTERIOR FACE OF WALL FULL HEIGHT OF THE WALL (BASIS OF DESIGN -
ROCKWOOL'S CAVITY ROCK). AT THE OPENING SILL, REMOVE EXISTING WINDOW SILL PAN AND
COUNTERFLASHING. INSTALL NEW WOOD BLOCKING AND WRAP WITH SELF-ADHERED
WATERPROOFING. INSTALL NEW SILL PAN/TWO-PIECE COUNTERFLASHING. SILL PAN TO HAVE
MINIMUM 1" VERTICAL END DAM AT INTERIOR AND JAMBS. LINE PAN WITH SELF-ADHERED
WATERPROOFING. INSTALL NEW ROOF COUNTER-FLASHING. INSTALL NEW FIXED ALUMINUM
LEVEL "E" RATED HURRICANE IMPACT GLAZED 10-1
2" CURTAIN WALLS. BASIS OF DESIGN: YKK (YHC
300 OG) COMPLYING WITH FPA: 13433.2. INSTALL LEVEL "E" LARGE MISSILE TESTED GLAZING PER
FPA. COLOR TO BE REVIEWED AND APPROVED BY OWNERSHIP. SEAL THE PERIMETER EXTERIOR
CURTAIN WALL JOINTS WITH A DOUBLE BEAD OF SEALANT. SEAL ALL INTERIOR WINDOW JOINTS
WITH LATEX SEALANT. DUE TO WIDTH OF NEW CURTAIN WALL COMPONENTS, INSTALL NEW
METAL STUDS AND INTERIOR GYPSUM WALL BOARD AS REQUIRED TO BUILD OUT WALL FINISHES
AT WINDOW OPENINGS. INSTALL NEW GYPSUM AND ACOUSTICAL CEILING TILE COMPONENTS
TO ACCOMMODATE WALL BUILD OUT. INSTALL .063 ALUMINUM JAMB TRIM PROVIDED BY
WINDOW MANUFACTURER AT STUD PARTITION WALLS. FILL OPENING WITH FIRE-STOPPING AT
PARTITIONS. MODIFY EXISTING FLOOR FINISHES. AT FIRST FLOOR SOFFIT, PROVIDE METAL
CLOSURE AT FLOOR SLAB, SEALING BUILDING ENVELOPE. SET METAL IN SEALANT TAPE AND SEAL TO INTERIOR FACE OF CURTAIN WALL PANEL WITH SEALANT. INSTALL 2 HR FIRE STOP BARRIER AT CURTAIN WALL FLOOR/ROOF SLAB INTERFACE. BASIS FO DESIGN: HILTI - CFS-SP WB FIRESTOP FIRESTOP JOINT SPRAY. SEE DETAIL A8.20. SEE EXISTING SPECIFICATION SECTIONS 08 44 13 AND 08 80 00.
1.6 JAMB TRIM AT CURTAIN WALL COLUMNS: INSTALL .063" ALUMINUM JAMB TRIM BY
WINDOW MANUFACTURER AT COLUMNS AND CURTAIN WALLS TO ACCOMMODATE WIDTH OF THE
COLUMN ASSEMBLY. PAINT EXTERIOR FACE OF COLUMN BLACK TO CONCEAL FROM VIEW
THROUGH CURTAIN WALL. SEAL ALL JOINTS WITH TWO BEADS OF SEALANT.
2.0 PRECAST CONCRETE PANELS:
2.1 PRECAST CONCRETE WALL SEALANT REPLACEMENT: REMOVE ALL HORIZONTAL
AND VERTICAL SEALANTS ASSOCIATED WITH THE PRECAST CONCRETE PANEL SURFACES,
INCLUDING OVERHEAD SOFFITS. INSTALL A CLOSED CELL BACKER ROD AT ALL VERTICAL AND
HORIZONTAL JOINTS. PRIME WALL JOINT SUBSTRATES, AND APPLY NEW SECONDARY SEALANT
AT ALL HORIZONTAL AND VERTICAL JOINTS. PROVIDE ADDITIONAL BOND BREAKER AND APPLY A
SECOND LAYER OF SEALANT TO CREATE A "DOUBLE SEALANT" JOINT PROFILE. SEE
SPECIFICATION 07 92 00.
2.2 PRECAST CONCRETE WALL COATING: POWER WASH ALL PRECAST CONCRETE WALL
SURFACES. REMOVE ALL LOOSE COATINGS. PRIME AND PAINT ALL PREVIOUSLY PAINTED
SURFACES . BASIS OF DESIGN: CHEMTRETE -BSM400. SEE SPECIFICATION SECTION 09 91 00.
2.3 WALL PENETRATION, WALL MOUNTED EQUIPMENT AND LIGHTS SEALANT
REPLACEMENT: REMOVE ALL SEALANTS ASSOCIATED WITH THE WALL PENETRATIONS AND
WALL MOUNTED EQUIPMENT, INSTALL BACKER ROD AND SEALANT AT ALL JOINTS PENETRATING
THROUGH THE PRECAST CONCRETE WALL PANELS. SEE SPECIFICATION SECTION 07 92 00.
3.0 BRICK VENEER ASSEMBLY:
3.1 BRICK RESTORATION AND SEALING: REMOVE ALL LOOSE AND DETERIORATED
MORTAR FROM THE EXISTING BRICK VENEER MORTAR JOINTS AND RESTORE MORTAR JOINTS
USING A THREE STEP MASONRY TUCK-POINTING PROCESS. REPLACE ALL WALL PENETRATION
SEALANTS WITH NEW BACKER ROD AND SEALANTS. POWER WASH ALL BRICK VENEER WALL
SURFACES. APPLY CLEAR PENETRATING SEALER; BASIS OF DESIGN: CHEM-TRETE BMS400 BY
PROTECTOSIL, TO ALL BRICK WALL SURFACES. SEE SPECIFICATION SECTION 04 01 20 AND
07 19 00.
3.2 BRICK CRACK REPAIR: AT CRACKED BRICK LOCATIONS, GROOVE CUT EXISTING CRACK
PROVIDING 12" GROOVE. APPLY BOND BREAKER AND SEALANT. ASSUME 100 LF TO BE INCLUDED IN
BASE BID QUANTITIES.
3.3 BRICK CONTROL JOINTS: REMOVE AND REPLACE EXISTING EXTERIOR SEALANT AND
BACKER ROD AT ALL EXISTING CONTROL JOINTS. INSTALL NEW SEALANT. SEE SPECIFICATION
SECTION 07 92 00.
4.0 EXTERIOR LOUVER ASSEMBLIES:
4.1 LOUVER REFINISHING: REMOVE EXISTING SEALANTS FROM THE INTERFACE OF THE
LOUVER FRAMES AND ADJACENT PRECAST CONCRETE OR OTHER BUILDING ENVELOPE
COMPONENTS. INSTALL NEW BACKER ROD AND SEALANT. PRIME AND PAINT ALL PREVIOUSLY
PAINTED LOUVER FRAME SURFACES. MILL FINISHED ALUMINUM SURFACES TO REMAIN. SEE
SPECIFICATION SECTIONS 07 92 00 AND 09 90 00.
4.2 DIVERTER INSTALLATION: INSTALL NEW 20 GAUGE TYPE 316 STAINLESS STEEL
DIVERTER OVER ALL LOUVER ASSEMBLIES. SET VERTICAL FLANGE OF DIVERTER IN SEALANT TAPE
AND SECURE TO THE EXISTING PRECAST CONCRETE WALL ASSEMBLY WITH STAINLESS STEEL
EPDM GASKETED FASTENERS. SEE SPECIFICATION SECTION 07 62 00.
5.0 GLAZED DOOR ASSEMBLIES:
5.1 DEMOLITION: REMOVE ALL DESIGNATED EXISTING EXTERIOR DOORS AND THEIR
ASSOCIATED COMPONENTS INCLUDING BUT NOT LIMITED TO: DOORS, GLAZING, HARDWARE,
THRESHOLD, WOOD BUCKS, SHIMS, METAL FLASHINGS, FASTENERS, AND SEALANTS FROM THE
SURFACES OF THE EXISTING SUBSTRATES.
5.2 NEW GLAZED DOOR ASSEMBLY: INSTALL NEW YKK AP AMERICA, INC. ALUMINUM
DOOR (SERIES YKK 35H) WITH INSULATED, LEVEL "E" LARGE MISSILE IMPACT RATED TEMPERED
GLASS AND WITH PERIMETER SHIMS AND WITH AN EXTRUDED ALUMINUM, ACCESSIBLE
THRESHOLD. SEAL ALL EXTERIOR DOOR JOINTS WITH A DOUBLE BEAD OF SEALANT AT THE
PERIMETER OF THE EXTERIOR DOOR. INSTALL ALUMINUM HARDWARE MATCHING THE TYPE AND
KEYING OF THE ORIGINAL DOOR. AT CAVITY WALLS, TIE-INTO EXISTING SUBSTRATE AIR BARRIER.
FULLY SEAL TRANSITIONS TO PROVIDE AIR-TIGHT DETAIL.
5.3 NORTH ENTRANCE STOREFRONT CAST IN PLACE CONCRETE CURB: INSTALL A
NEW ENGINEERED CAST IN PLACE CONCRETE CURB AT NORTH ENTRANCE STOREFRONT TO
RAISE WINDOW SILL HEIGHT 12" ABOVE FINISHED GRADE. INSTALL NEW REINFORCEMENT PER
APPROVED DETAIL ON A/A5.3. INSTALL NEW .125 ANODIZED ALUMINUM CAP AT INTERIOR AND
EXTERIOR OF CURB TO MATCH WINDOW FRAME. PROVIDE WATER-STOP AT ALL COLD JOINTS.
BASIS OF DESIGN: ADCORE 500S BY GCP APPLIED TECHNOLOGIES. COORDINATE INSTALLATION
WITH BUILDING SECURITY.
5.4 NORTH ENTRANCE STOREFRONT FRAMING: FOLLOWING THE REMOVAL OF THE
EXISTING STOREFRONT, SHORE OPENING AS REQUIRED. INSTALL NEW HSS FRAMING AT HEAD
AND JAMBS TO SUPPORT NEW LEVEL "E" STOREFRONT ASSEMBLY PER FPA. PROVIDE
ENGINEERED SIGNED AND SEALED DOCUMENTS FOR FRAMING AND WINDOW INSTALLATION.
BASIS OF DESIGN: YKK AP AMERICA, INC. ALUMINUM DOORS (SERIES YKK35H) WITH INSULATED LEVEL "E" LARGE MISSILE IMPACT RATED GLASS. PROVIDE BACK PLATE AT FRAME TO PROVIDE
DOUBLE PERIMETER SEALANT JOINT. INSTALL NEW ADA THRESHOLD AT DOORWAY. BASIS OF
DESIGN: ZERO INTERNATIONAL, RABBETED THRESHOLD #65, OR APPROVED EQUAL. SET IN FULL
BED OF TRAFFIC RATED SEALANT.
6.0 PAINTED HOLLOW METAL DOORS:
6.1 HOLLOW METAL DOOR RESTORATION: REMOVE ALL SEALANTS FROM THE EXISTING
DOOR COMPONENTS. PROPERLY PREPARE ALL SURFACES AND INSTALL NEW BOND BREAKER
AND SEALANT AT PERIMETER DOOR FRAME JOINTS. TREAT ANY CORRODED METAL SURFACES,
PRIME AND PAINT ALL DOOR FRAME AND DOOR LEAF SURFACES. INSTALL 20 GAUGE TYPE 316
STAINLESS STEEL RAIN DIVERTER FLASHING OVER DOOR ASSEMBLIES. REMOVE AND REPLACE
EXISTING THRESHOLDS. BASIS OF DESIGN: ZERO INTERNATIONAL RABBETED THRESHOLD #65 OR
APPROVED EQUAL. SET IN FULL BED OF TRAFFIC RATED SEALANT. INSTALL TRAFFIC RATED
SEALANTS AT THE INTERFACE OF THE EXISTING DOOR THRESHOLD AND DOOR JAMB FRAMING.
REMOVE AND REPLACE WEATHER STRIPPING AND SWEEPS. SEE SPECIFICATION SECTIONS 07 92
00 AND 09 91 13.
6.2 DIVERTER INSTALLATION AT ROOF ACCESS DOOR: INSTALL NEW 20 GAUGE TYPE
316 STAINLESS STEEL DIVERTER OVER PAINTED HOLLOW METAL ROOF ACCESS DOOR ASSEMBLY.
SET VERTICAL FLANGE OF DIVERTER IN SEALANT TAPE AND SECURE TO THE EXISTING WALL
ASSEMBLY WITH GASKETED EPDM STAINLESS STEEL FASTENERS. SEE SPECIFICATION SECTION
07 62 00.
7.0 STUCCO WALL AND SOFFIT ASSEMBLY:
7.1 EXISTING STUCCO RESTORATION: ROUTE OUT ALL CRACKED STUCCO SURFACES.
PATCH STUCCO WITH NEW TEXTURED SEALANT, MATCHING STUCCO TEXTURE. PRESSURE CLEAN
ALL WALL AND SOFFIT SURFACES AND APPLY PRIMER AND HIGH PERFORMANCE COATING
SYSTEM TO ALL STUCCO WALL SURFACES. REPLACE ALL SEALANTS ASSOCIATED WITH THIS
WALL ASSEMBLY. AT ALL WALL AND SOFFIT PENETRATIONS, FILL ANNULAR SPACE WITH BACKER
ROD AND SEALANT. APPLY SEALANT AT ALL VERTICAL AND HORIZONTAL STUCCO CONTROL
JOINTS AND STUCCO REVEALS MAINTAINING PROFILES OF EXISTING JOINTS AND REVEALS.
INCLUDE 50 LINEAR FEET OF STUCCO CRACK REPAIR WITHIN BASE BID. INSTALL IN-FIELD
MOCK-UP OF STUCCO CRACK REPAIR FOR OWNER/ARCHITECT APPROVAL. SEE SPECIFICATION
SECTIONS 07 92 00 AND 09 91 13.
8.0 ROOFING REPAIRS:
8.1 COPING WATERPROOFING: REMOVE ALL SEALANTS ASSOCIATED WITH THE EXISTING
PARAPET WALL COPING ASSEMBLY. PRIME METAL SURFACES AND INSTALL NEW SILICONE TAPE:
BASIS OF DESIGN: DOWSIL 123 SEALANT TAPE AT ALL COPING END JOINTS, TERMINATIONS AND
TRANSITIONS. SEE SPECIFICATION SECTION 07 92 00.
8.2 ROOF REPAIRS AT FIRST FLOOR ROOFING ASSEMBLIES: AT FIRST FLOOR ROOFING
ASSEMBLIES, REMOVE AND REPLACE EXISTING COUNTER FLASHINGS. AT CURTAIN WALL, INSTALL
NEW TWO PIECE ALUMINUM COUNTER-FLASHING WITH CONTINUOUS CLEATS. AT EXISTING
PRECAST CONCRETE PANELS, SAWCUT NEW REGLET TO RECEIVE NEW TWO-PIECE FLASHINGS.
FABRICATE AND INSTALL NEW 22 GAUGE 316 STAINLESS STEEL RECEIVER AND
COUNTERFLASHING SYSTEM SECURED TO THE EXISTING WALL ASSEMBLY. PROVIDE
CONTINUOUS METAL CLEAT OF 20 GAUGE 316 STAINLESS STEEL.
8.3 ROOF FLASHING REPLACEMENT AT THE NORTH FIRST FLOOR ROOFING
ASSEMBLIES: AT THE NORTH MAIN ENTRANCE FIRST FLOOR SETBACK ROOF, INSTALL NEW
FLASHING ASSEMBLY IN COORDINATION WITH THE NEW FASICA PANEL INSTALLATION. REMOVE
AND REPLACE EXISTING AS PER EXISTING SINGLE-PLY ROOFING MANUFACTURER'S
REQUIREMENTS TO COMPLY WITH EXISTING WARRANTY REQUIREMENTS.
8.4 ROOF COATING AT FIRST FLOOR ROOFING ASSEMBLIES: AT THE FIRST FLOOR
ROOFING ASSEMBLIES, PRESSURE WASH EXISTING ROOF ASSEMBLY. AT ROOF NOT PREVIOUSLY
COATED, PREP PER MANUFACTURER'S SPECIFICATIONS AND APPLY NEW FULLY REINFORCED
ROOF COATING. PROVIDE ENGINEERED MOISTURE SCAN OF EXISTING ROOF ASSEMBLY. REMOVE
AND REPLACE ANY WET ROOF AREAS PER MANUFACTURER'S REQUIREMENTS. APPLY TWO PART
URETHANE ROOF COATING. SEE SPECIFICATION SECTION 07 56 10.
8.5 ROOF FLASHING REPLACEMENT AT MAIN ROOFING ASSEMBLIES: INSTALL NEW
FLASHING AT INTERIOR FACE OF NEWLY CONSTRUCTED PARAPET. REMOVE EXISTING FLASHING
WITH CURTAIN WALL DEMOLITION. INSTALL NEW TWO-PLY MODIFIED BITUMEN BASE FLASHING, COVERBOARD AND INSULATION EXTENDING TO THE TOP OF THE NEW PARAPET WALL EXTENDING
FOUR FEET INTO THE FIELD OF THE ROOF. ASSEMBLY TO COORDINATED WITH CURRENT ROOF
MANUFACTURER TO ENSURE FLASHING IS INCLUDED INTO EXISTING WARRANTY. INSTALL NEW
METAL COPINGS AT NEW CURTAIN-WALL SECTION. COPINGS TO BE ENGINEERED ANSI-SPRI ES-1
TESTED ASSEMBLIES. TIE-IN EXISTING COPING WITH MIN 12" TRANSITION COPING.
8.6 ROOF PARAPET WALL CONSTRUCTION: AT THE MAIN AND FIRST FLOOR NORTH WALL
ROOF, INSTALL NEW PARAPET WALL AND CURB COORDINATED WITH CURTAIN WALL AND FASCIA
PANEL INSTALLATION. AT THE MAIN ROOF, INSTALL NEW 4"X4"X3
8" HSS ATTACHED TO THE EXISTING
ROOF DECK AT MULLION LOCATIONS WITH NEW ANGLE CLIPS ANCHORED WITH HILTI-HIT HY 270, MIN. 4" EMBEDMENT. INSTALL NON-STRUCTURAL STEEL FRAMING AT 16" O.C AND INSULATION
BETWEEN HSS TUBES. INSTALL NEW COVERBOARD IN COORDINATION WITH ROOFING
INSTALLATION. TUBES TO BE ENGINEERED IN COORDINATION WITH CURTAIN WALL SHOP
DRAWINGS.
8.7 LIGHTNING PROTECTION: AT THE MAIN ROOF, TEMPORARILY REMOVE ALL EXISTING
LIGHTNING AIR TERMINALS AND CABLES AS REQUIRED WHICH ARE ATTACHED TO COMPONENTS
DESCRIBED IN THIS SCOPE OF WORK. PROVIDE FULLY OPERATIONAL LIGHTNING PROTECTION
SYSTEM DURING CONSTRUCTION. REPLACE ALL DETERIORATED/DAMAGED AIR TERMINALS.
REINSTALL LIGHTNING PROTECTION SYSTEM IN ACCORDANCE WITH NFPA-780 BY A LICENSED
CONTRACTOR WITH A MINIMUM OF 5 YEARS OF EXPERIENCE. IN THE INSTALLATION OF LIGHTNING PROTECTION SYSTEMS, RE-CERTIFY THE LIGHTNING PROTECTION SYSTEM. SEE SPECIFICATIONS
SECTION 13 10 00.
8.8 FIRST FLOOR SETBACK REGLET COUNTERFLASHING: AT THE FIRST FLOOR
COVERED WALKWAY, REMOVE AND REPLACE REGLETTED COUNTERFLASHING AT PRECAST WALL.
INSTALL NEW TWO-PIECE COUNTERFLASHING WITH CONTINUOUS CLEAT. SEE SPECIFICATION
SECTION 07 62 00.
9.0 FIRST FLOOR SETBACK FASCIA PANELS:
9.1 FIRST FLOOR FASCIA PANELS: AT THE NORTH FACADE, REMOVE AND REPLACE THE
FIRST FLOOR FASCIA PANELS TO MATCH THE NEW SPANDREL GLASS PANELS AT THE CURTAIN
WALL. PROVIDE ENGINEERED SHOP DRAINGS COMPLYING WITH FBC AND THE FLORIDA PRODUCT
APPROVAL, MEETING ALL WIND UPLIFT PRESSURES. REMOVE AND REPLACE VENTED SOFFIT
PANELS TO MATCH EXISTING.
10.0 HARDSCAPE SEALANT JOINT:
10.1 REPLACEMENT OF HARDSCAPE JOINT: REMOVE AND REPLACE EXISTING SEALANT
JOINT BETWEEN SIDEWALK AND VERTICAL BUILDING WALL. INSTALL NEW PREMOLDED JOINT FILL
AND SELF LEVELING TRAFFICABLE SEALANT. SEE SPECIFICATION SECTION 07 92 00.
11.0 WALL PENETRATIONS:
11.1 WALL PENETRATION SEALANT REPLACEMENT: REMOVE AND REPLACE EXISTING
SEALANT AT EXISTING WALL PENETRATIONS. INSTALL BOND BREAKER AND SEALANT AROUND
PENETRATIONS. SEE SPECIFICATION SECTION 07 92 00.
12.0 INTERIOR COMPONENTS, FINISHES AND INSULATION:
12.1 DEMOLITION: REMOVE ALL INTERIOR FINISHES AS REQUIRED TO INSTALL NEW CURTAIN
WALL AND WINDOW ASSEMBLY COMPONENTS INCLUDING BUT NOT LIMITED TO GYPSUM BOARD,
METAL STUDS, SEALANTS, WINDOW STOOLS, CEILING COMPONENTS AND FLOOR FINISHES.
12.2 INSULATION AND FIREPROOFING: WHERE EXISTING INSULATION AND FIREPROOFING
WAS REMOVED AT WINDOW OPENINGS, INSTALL NEW R-13 BATT OR SPRAYED POLYURETHANE
FOAM INSULATION WITH FIRE RATED INTUMESCENT COATING. BASIS OF DESIGN: HILTI CW-S-2028
2-HR FIREPROOFING AT ALL FLOOR SLABS AND TERMINATIONS.
12.3 METAL STUDS AND GYPSUM SHEATHING: INSTALL NEW METAL STUD FRAMING AND
GYPSUM SHEATHING WHERE EXISTING GYPSUM SHEATHING OR PLASTER WERE REMOVED AND
AT WALL LOCATIONS WHERE NEW STUD FRAMING WAS INSTALLED TO ACCOMMODATE CURTAIN
WALL WIDTH. AT NEW CURTAIN WALL COMPONENTS, EXTEND METAL STUD FRAMING AND
GYPSUM SHEATHING TO THE ADJACENT PARTITION WALLS. TIE-IN NEW GYPSUM SHEATHING
WITH ADJACENT EXISTING GYPSUM SHEATHING.
12.4 GYPSUM AND ACOUSTICAL CEILING PANEL ASSEMBLIES: MODIFY EXISTING AND
INSTALL NEW GYPSUM BOARD AND/OR ACOUSTICAL CEILING PANEL ASSEMBLY AS REQUIRED TO
INSTALL NEW CURTAIN WALL AND WINDOW COMPONENTS.
12.5 PAINTING: PRIME AND PAINT ALL INTERIOR WALL AND CEILING SURFACES ADJACENT TO THE WINDOW COMPONENTS. PRIME AND PAINT THE INTERIOR SURFACES (FLOOR TO CEILING) OF
THE EXISTING AND NEW INTERIOR GYPSUM WALLBOARD AT NEW WINDOW ASSEMBLIES. SEE
SPECIFICATION SECTION 09 91 25
12.6 INTERIOR BLINDS: INSTALL NEW ROLL-UP BLINDS (MATCH EXISTING) AT ALL BLIND
LOCATIONS.
12.7 INTERIOR SEALANTS: SEAL ALL INTERIOR WINDOW JOINTS WITH ACRYLIC LATEX
SEALANT.
12.8 ELECTRICAL COMPONENTS: MODIFY EXISTING ELECTRICAL COMPONENTS TO
ACCOMMODATE NEW INTERIOR FINISHES.
12.9 INTERIOR TILES: REMOVE AND REPLACE EXISTING FLOOR TILES AND BASE COVES AS
NECESSARY TO INSTALL NEW WINDOW ASSEMBLIES. REPLACE IN-KIND WITH APPROVED TILE
MATCHING EXISTING AND THIN SET MORTAR BY LATICRETE.
12.10 INTERIOR CONSTRUCTION BARRIER: INSTALL INTERIOR CONSTRUCTION BARRIER
ISOLATING CONSTRUCTION AREA FROM INTERIOR OCCUPIED SPACE. INSTALL USING WALL
FRAMING AND SOLID PARTITION. PROVIDE DUST CONTROL AND AIR BARRIER.
SHEET
REVISIONS
KAK / CAS
APPROVED BY:
DRAWN BY:
JPA
NUMBER TYPE
JULY 8, 2022
PROJECT NUMBER:
DATE:
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .