Orange County Convention Center South Concourse Command Center Upgrades
Solicitation number
Y24-733
Issued by
Orange County, Orlando City, Florida

About this file

The document is a comprehensive set of mechanical, electrical, and architectural drawings for the Orange County Convention Center South Concourse Command Center Upgrades project in Florida. The drawings, prepared by ADC Architectural Design Collaborative, detail the proposed renovations for upgrading the command center, including mechanical, electrical, and power system modifications. The project involves relocating existing equipment, installing new conduits and wiring, updating lighting and control systems, and implementing new IDF (Intermediate Distribution Frame) cabinets. The project is estimated to cost $214,406.00, with electronic bid submissions due by 4:00 pm EST on Thursday, January 18, 2024, through the ProcureNow OpenGov e-Procurement Platform.

The drawings provide extensive technical specifications for the renovation, including detailed plans for mechanical symbol specifications, demolition plans, proposed floor plans, lighting and power layouts, and electrical details. The scope includes specific requirements for ductwork, electrical systems, fire alarm devices, and cable installations. The project appears to be focused on modernizing and improving the technological infrastructure of the command center, with particular attention to precise equipment placement, wiring configurations, and compliance with building and electrical codes. The documents indicate a comprehensive approach to upgrading the facility's technological capabilities while maintaining existing system functionalities.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RETURN GRILLE

LEAVING DRY BULB

KILOWATT

INSIDE DIAMETER

HERTZ (CYCLES PER SECOND)

MAXIMUM

MANUAL DAMPER

NUMBER, NORMALLY OPEN

NOT APPLICABLE

NOT TO SCALE

LOR LIMIT OF REMOVAL

OUTSIDE DIAMETER

OPPOSED BLADE DAMPER

OUTSIDE AIR

OPERATING

REGISTER

RETURN FAN

RETURN AIR

POUNDS PER SQUARE INCH GAUGE

POUNDS PER SQUARE INCH

MASTER BUILDING CONTROLLER

THOUSAND BTU PER HOUR

LEAVING WET BULB

SUPPLY AIR

REHEAT COIL

SMOKE/FIRE DAMPER

TEMPERATURE

THERMOSTAT

SUPPLY FAN

VERTICAL

VOLUME DAMPER

WET BULB

VENT, VOLT

THREE WAY BLOW

TWO WAY BLOW

ONE WAY BLOW

WATER PRESSURE DROP

TERMINAL EQUIPMENT CONTROLLER

RELATIVE HUMIDITY

HEATING HOT WATER SUPPLY&RETURN

HOURHR

AND AIR CONDITIONING

HEATING VENTILATINGHVAC

GALLONS PER MINUTE

HORSEPOWER, HEAT PUMP

HAND-OFF-AUTOMATIC

FIRE/SMOKE DAMPER

FEET PER SECOND

GALLONS PER HOUR

FIRE DAMPER, FLOOR DRAIN

ENTERING WET BULB

FEET PER MINUTE

FAHRENHEIT

FEETFT

HHWS&R

HOA

HP

GPH

GPM

FPM

FPS

F/SD

EWB

F

FD

3WB

2WB

1WB

WPD

WB

VERT

V

VD

CHILLED WATER SUPPLY & RETURN

ENERGY MANAGEMENT SYSTEM

EXISTING RETURN GRILLE

DOMESTIC HOT WATER

DISCONNECT

DELIVERY

ENTERING AIR TEMPERATURE

ENTERING

EXHAUST FAN

ELEVATION

EFFICIENCY

ENTERING DRY BULB

EXHAUST AIR, EACH

EAT

ELEV

ERG

ENT

EMS

EDB

EFF

EF

DN

EA

DISC

DHW

DELIV

DOWN

CLEAN OUT

DRY BULB, DOWN BLOW

DOMESTIC COLD WATER

CONDENSATE

BRITISH THERMAL UNIT

BACKFLOW PREVENTER

CUBIC FEET PER MINUTE

CELSIUS, DEGREE CELSIUS

CENTRIFUGAL

CEILINGCLG

DEG

DCW

DB

COND

CO

DEGREE

CHWS&R

CFM

CENT

BTU

BFP

C

SF

TEC

TS

TEMP

S/FD

T

TEMPERATURE SENSOR

RM

SA

RHC

RG

RH

ROOM

REG

RF

RA

PSIG

PSI

NO OR #

OA

OBD

OPER

OD

NTS

MECHANICAL ABBREVIATIONS

AUTOMATIC TEMPERATURE CONTROL

AAV AUTOMATIC AIR VENT

ABOVE FINISHED GRADE

ABOVE FINISHED FLOOR

ACCESS DOOR, AIR DRYER

AIR CONDITIONING UNIT

BACK DRAFT DAMPER

AIR VENT

ACCESS PANEL

AIR PRESSURE DROP

AIR HANDLING UNIT

ALUMINUM

AIR CONDITIONING

ALUM

AV

BOT

BDD

ATC

APD

AP

BOTTOM

AFF

AHU

AFG

ACU

AC

AD

A AIR

MAX

NA

N

MIN

MBH

MBC

MD

NORTH

MINIMUM

LDB

LWB

ID

KW

IN INCH

HZ

EMS ENERGY MANAGEMENT SYSTEM

FLEXIBLE ROUND DUCT

CO CARBON DIOXIDE SENSOR

A-350

FIRE DAMPER AND ACCESS DOOR.

DAMPER, WITH ACCESS DOOR.

COMBINATION FIRE AND SMOKE

ROUND DUCT, DIAMETER SHOWN

F

SD SD

H

T THERMOSTAT OR TEMPERATURE SENSOR

FIRE STAT

SMOKE DETECTOR

HUMIDITY SENSOR

VOLUME DAMPER

SPIN-IN COLLAR WITH

M

BD

FSD

24X12

FD

BACKDRAFT DAMPER

MOTORIZED DAMPER

FIGURE IS SIDE SHOWN

RECTANGULAR DUCT, FIRST

AIR DISTRIBUTION DESIGNATION

EXHAUST AIR REGISTER/GRILLE

RETURN AIR REGISTER/GRILLE

SQUARE SUPPLY AIR DIFFUSER

SIDEWALL REGISTER OR GRILLE

AIR QUANTITY

TYPE

DUCT CONNECTION

FLEXIBLE CONNECTION

CEILING DIFFUSER - SIDE

4-WAY DISCHARGE

SUPPLY AIR DUCT - SECTION

UP

DN

ELBOW TURNED DOWN

CEILING DIFFUSER -

STANDARD BRANCH TAKEOFF

BOTTOM DUCT CONNECTION

FLOOR/CEILING ASSEMBLY

FLOOR/CEILING ASSEMBLY

EXHAUST AIR DUCT - SECTION

SUPPLY DUCT UP THRU ROOF OR

RETURN DUCT UP THRU ROOF OR

RETURN AIR DUCT - SECTION

OFFSET IN DUCTWORK - UP

OFFSET IN DUCTWORK - DOWN

TEE WITH DOUBLE THICKNESS

MANUAL DAMPER

RADIUS ELBOW

MITERED ELBOW - WHERE USED PROVIDE TURNING VANES

ELBOW TURNED UP

DUCTWORK

MECHANICAL SYMBOLS LEGEND

NEW WORK

MECHANICAL LEGEND

-CHILLED WATER SUPPLYCHWS

-CHILLED WATER RETURNCHWR

-CONDENSATE DRAINCD

-REFRIGERANT LIQUIDRL

-REFRIGERANT SUCTIONRS

-GATE VALVE

-BALL VALVE

-CALIBRATE BALANCING VALVE

-BUTTERFLY VALVE

-GAS COOK

-UNION

-STRAINER

-PSI REG.

-CHECK VALVE

-CONNECTION, BOTTOM

-CONNECTION, TOP

-ELBOW, TURNED UP

-ELBOW,TURNED DOWN

-REDUCER, CONCENTRIC

-REDUCER, ECCENTRIC STRAIGHT CROWN

-CAP

SECTION TAG

EXISTING PIPING

NEW PIPING

HWS

HWR

-HOT WATER SUPPLY

-HOT WATER RETURN

HATCH INDICATES DEMO ITEM

EXISTING DUCTWORK AND/OR PIPING

BALL VALVEBV

TYP TYPICAL

DPS DIFFERENTIAL PRESSURE SWITCH

PRESSURE GAUGEPG

WIRE MESH SCREENWMS

SMOKE DAMPER

FIRE/SMOKE DAMPER

FIRE DAMPER

STR MOTOR STARTER

VFD VARIABLE FREQUENCY DRIVE

ENLARGED PLAN TAG, FLOOR PLAN REFERENCE

ENLARGED PLAN REFERENCE

FLOOR PLAN:

ENLARGED PLAN:

SP STATIC PRESSURE SENSOR

M200

M400

M400 A

MECHANICAL SCOPE OF WORK:

1. BALANCE EXISTING TO REMAIN SUPPLY DIFFUSERS AND BALANCE CFM VALUE INDICATED

2. RELOCATION OF EXISTING THERMOSTAT

3. RELOCATION OF EXISTING CONTROL PANEL

4. EXISTING RETURNS AND DIFFUSERS CURRENT LOCATION TO REMAIN FOR RE-USE

MECHANICAL GENERAL NOTES

1. THE CONTRACTOR SHALL DEMONSTRATE EACH HVAC SYSTEMS PERFORMANCE IN THE PRESENCE OF THE ARCHITECT AND THE OWNER'S PROJECT

MANAGER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COST OF ANY ADDITIONAL SYSTEM TEST REQUIRED IF IN THE OPINION OF THE ARCHITECT AND THE OWNERS PROJECT MANAGER THE SYSTEMS DO NOT PERFORM AS SPECIFIED.

2. IF, THE INTENT OF ARCHITECT/ ENGINEER WITH REGARD TO ANY DETAIL IS NOT CLEAR, OR IS CAPABLE OF MORE THAN ONE INTERPRETATION, SUCH MATTERS WILL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER IN WRITING BEFORE THE SUBMISSION OF BIDS, AND THE ARCHITECT/ ENGINEER SHALL MAKE CORRECTION OR EXPLANATION IN WRITING. OTHERWISE, NO EXTRA CHARGE WILL BE ALLOWED FOR THE WORK OR MATERIAL WHICH THE ARCHITECT/ENGINEER WILL REQUIRE, PROVIDED THAT IT COMES WITHIN A REASONABLE INTERPRETATION OF THE DRAWINGS AND

SPECIFICATIONS.

3. THE PLANS AND SPECIFICATIONS ARE INTENDED AS A GENERAL DESCRIPTION OF THE WORK TO BE PERFORMED. ALL ITEMS NOT SPECIFICALLY MENTIONED OR SHOWN, BUT NECESSARY FOR THE COMPLETION OF THE INSTALLATION, SHALL BE FURNISHED AND INSTALLED BY THIS CONTRACTOR.

THIS CONTRACTOR SHALL THOROUGHLY ACQUAINT HIMSELF WITH THE MECHANICAL, ARCHITECTURAL AND ELECTRICAL PLANS BEFORE SUBMITTING HIS FINAL BID. NO ADDITIONAL COMPENSATION WILL BE ALLOWED DUE TO THE CONTRACTOR'S FAILURE TO FAMILIARIZE HIMSELF WITH THE PLANS.

4. UNFORESEEN CONDITIONS MAY EXIST AND WORK MAY NOT BE FIELD LOCATED EXACTLY AS SHOWN ON THE DRAWINGS. COOPERATION WITH OTHER TRADES IN ROUTING AND/OR BURIAL DEPTHS AS DETERMINED DURING CONSTRUCTION AND AS DIRECTED BY THE ARCHITECT/ENGINEER MAYBE NECESSARY. IT IS INTENDED THAT SUCH DEVIATIONS SHALL BE CONSIDERED AS PART OF THIS CONTRACT. SUCH DEVIATIONS MAY NOT BE CONSIDERED AS PART OF THIS CONTRACT WHEN PROPERLY DOCUMENTED IN WRITING. THE PLANS ARE NOT COMPLETELY TO SCALE. CONTRACTOR IS TO FIELD VERIFY DIMENSIONS OF ALL SITE UTILITIES ETC PRIOR TO BID AND INCLUDE ANY DEVIATIONS IN THE CONTRACT.

5. ALL PIPING AND DUCT IS TO BE CONCEALED ABOVE CEILING OR IN NEW WALLS UNLESS SPECIFICALLY NOTED AS EXPOSED OR SURFACE MOUNTED.

CONTRACTOR TO COORDINATE WITH THE GENERAL CONTRACTOR TO PAINT ALL EXPOSED PIPING TO MATCH CORRESPONDING EXPOSED AREAS.

6. ALL WORK SHALL BE IN ACCORDANCE WITH THE 2020 FLORIDA BUILDING CODE AND ALL LOCAL CODES.

7. THE SIZE AND LOCATION OF EQUIPMENT INSTALLED UNDER DIVISION 23 MECHANICAL SHALL BE COORDINATED WITH OTHER TRADES. CONNECTION TO EQUIPMENT SHALL BE VERIFIED WITH MANUFACTURER'S CERTIFIED DRAWINGS. TRANSITIONS TO ALL EQUIPMENT SHALL BE VERIFIED AND PROVIDED

FOR EQUIPMENT FURNISHED.

8. PROVIDE A VOLUME DAMPER AT EVERY BRANCH DUCT AND AS SHOWN ON THE DOCUMENTS FOR ALL DUCTWORK SYSTEMS. ALL DAMPERS MAY NOT BE

SHOWN ON THE DOCUMENTS FOR CLARITY.

9. VERIFY EXISTING CONDITIONS IN FIELD AND COORDINATE WITH ALL TRADES INCLUDING, BUT NOT LIMITED TO, ARCHITECTURAL, STRUCTURAL, LIGHTING, POWER, SYSTEMS, PLUMBING, FIRE PROTECTION AND OTHER EXISTING AND NEW WORK.

10. INTERRUPTION OF EXISTING SERVICES SHALL BE MINIMAL AND SHALL BE FULLY COORDINATED WITH THE OWNER AND ALL TRADES IN ADVANCE TO

SCHEDULE ALL INTERRUPTIONS DURING NON-CRITICAL TIMES.

11. ALL EQUIPMENT, DUCTWORK, ETC., SHALL BE SUPPORTED AS DETAILED AND/OR SPECIFIED. PROVIDE ADDITIONAL SUPPORTS AS REQUIRED TO PROVIDE A VIBRATION-FREE, RIGID INSTALLATION. SUPPORT ALL OBJECTS FROM STRUCTURE WITHOUT PENETRATING THE CEILING.

12. REFER TO TYPICAL DETAILS FOR PIPING AND INSTALLATION OF EQUIPMENT.

13. ALL DUCTWORK SHALL BE CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH NFPA 90A AND 90B.

14. DUCT SIZES SHOWN ARE MINIMUM INSIDE DIMENSIONS.

15. BEFORE FABRICATION, VERIFY AND COORDINATE ALL DIMENSIONS IN FIELD. DUCT SIZES AND ALL OPENINGS THROUGH BUILDING CONSTRUCTION SHALL

SUIT EQUIPMENT FURNISHED.

16. ALL WORK SHALL BE COORDINATED WITH ALL TRADES INVOLVED. OFFSETS IN DUCTS AND PIPING (INCLUDING DIVIDING DUCTS) AND TRANSITIONS

AROUND OBSTRUCTIONS SHALL BE PROVIDED AT NO ADDITIONAL COST.

17. ALL DUCTWORK AND PIPING IS SHOWN SCHEMATICALLY. PROVIDE ALL TRANSITIONS, ELBOWS, FITTINGS, ETC., TO ALLOW SMOOTH FLOWS. ALL SPLIT DUCT FITTINGS SHALL TRANSITION TO FULL SIZE OF THE SUM OF BOTH BRANCHES UPSTREAM OF SPLIT.

18. ACCESS PANELS IN DUCTWORK AND CEILINGS SHALL BE PROVIDED WHERE REQUIRED FOR OPERATION, BALANCING AND MAINTENANCE OF ALL

MECHANICAL EQUIPMENT.

19. ALL DUCT BENDS FROM VERTICAL TO THE HORIZONTAL AND ANGLED TURNS OF DUCTWORK SHALL HAVE LONG RADIUS ELBOWS INSTALLED.

20. MAINTAIN CLEARANCE OF A MINIMUM OF 6" BETWEEN DUCTWORK, PIPING, EQUIPMENT, ETC., AND ALL FIRE RATED AND FIRE/SMOKE RATED PARTITIONS

TO ALLOW FOR INSPECTIONS OF RATED WALLS.

21. DIFFUSER NECKS SHALL MATCH SIZES OF FLEX DUCTS TO BE CONNECTED.

22. FLEXIBLE DUCTWORK SHALL BE FULLY EXTENDED NOT TO EXCEED 8'-0" IN LENGTH.

23. COORDINATE DIFFUSER, GRILLE AND REGISTER LOCATIONS WITH ARCHITECTURAL REFLECTED CEILING PLANS AND EQUIPMENT OF ALL TRADES.

24. COORDINATE WITH ARCHITECT BEFORE PURCHASING GRILLES, REGISTERS, DIFFUSERS, LOUVERS AND OTHER AIR DISTRIBUTION DEVICES TO VERIFY

FINISH.

25. DAMPERS AND INSIDES OF DUCTS VISIBLE THROUGH GRILLES, REGISTERS AND DIFFUSERS SHALL BE PAINTED FLAT BLACK.

26. ALL SUPPLY AND RETURN DUCTWORK SHALL BE INSULATED GALVANIZED STEEL. DUCTWORK SHALL BE SUPPORTED WITH MINIMUM 1" SHEET METAL

STRAPS AT 5'-0" ON CENTERS.

27. PROVIDE FIRE DAMPERS AT EACH FIRE RATED WALL PENETRATION OF ALL AIR SUPPLY, RETURN, EXHAUST AND VENTILATION DUCTS. IF NOT SHOWN ON THE DOCUMENTS THIS MUST BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO BID.

28. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING MATERIALS, EQUIPMENT, APPLIANCES AND DEVICES THAT ARE TO BE REUSED SHALL BE RECONDITIONED, TESTED AND PLACED IN GOOD AND PROPER WORKING CONDITION AND APPROVED. ANY DISCREPANCIES MUST BE BROUGHT TO THE

ATTENTION OF THE ENGINEER PRIOR TO BID.

29. ALL EQUIPMENT SHALL BE FREE OF ANY DAMAGE AT THE TIME OF ACCEPTANCE. ALL DENTS, SCRATCHES, AND ANY OTHER DAMAGE MUST BE REPAIRED

PRIOR TO THE INSTALLATION OF THE EQUIPMENT.

30. ALL DUCTWORK SHALL BE GALVANIZED SHEET METAL WITH EXTERNALLY WRAPPED INSULATION AND INSTALLED PER SMACNA GUIDELINES.

DUCTS/MATERIALS SHALL BE PROPERLY STORED, PROTECTED FROM MOISTURE, DUST AND DEBRIS, AND INTERIORS CLEANED PRIOR TO INSTALLATION.

31. ALL SUPPLY, RETURN, EXHAUST, AND OUTSIDE AIR BRANCH OR RUN-OUT DUCTS SHALL BE PROVIDED WITH MANUAL DAMPERS FOR AIR VOLUME

CONTROL AND ADJUSTMENT.

32. AIR HANDLING AND DUCTWORK SYSTEMS SHALL BE PROTECTED FROM CONSTRUCTION DUST AND WEATHER DURING THE CONSTRUCTION PERIOD.

AFTER CONSTRUCTION, SYSTEMS SHALL BE OBSERVED BY THE ENGINEER AND CLEANED BY CONTRACTOR IF NECESSARY.

33. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR COORDINATING HIS/HER WORK WITH THE TEST AND BALANCE FIRM. PRIOR TO TEST AND BALANCE, THE CONTRACTOR SHALL START-UP, PRE-BALANCE, AND REPLACE ALL AIR FILTERS FOR EVERY AHU BEING TESTED. ALL DISCREPANCIES, DRIVE CHANGES, ETC. REPORTED BY ENGINEER OR TEST AND BALANCE FIRM SHALL BE CORRECTED BY CONTRACTOR WITHIN FIVE CALENDAR DAYS AT NO ADDITIONAL COST. TEST AND BALANCE SHALL BE COMPLETED PRIOR TO SUBSTANTIAL COMPLETION. THE TEST AND BALANCE SHALL BE INCLUDED IN CONTRACTOR'S

SCOPE OF WORK.

34. OPERATION AND MAINTENANCE MANUALS SHALL INCLUDE AS A SEPARATE SUBMITTAL ITEM A LIST OF ALL EQUIPMENT INSTALLED, AND PREVENTATIVE MAINTENANCE REQUIREMENTS ALONG WITH TIME SCHEDULE(S) FOR EACH ITEM. THE SEQUENCE OF OPERATION SHALL ALSO INCLUDE A DEFINITIVE SEQUENCE OF OPERATION OF THE MECHANICAL SYSTEM AND COMPONENTS AS THEY FUNCTION INTEGRALLY AND INDEPENDENTLY WITH THE SYSTEM.

THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING TRANSFERRING CONTROL OF THE SYSTEM TO THE OWNER ENERGY CONTROL DEPARTMENT PRIOR TO FINAL CLOSEOUT OF THE PROJECT. THIS IS REQUIRED PRIOR TO ISSUANCE OF ANY FORM OF OCCUPANCY CERTIFICATE

35. THE HVAC SYSTEMS SHOULD BE TESTED AND BALANCED UNDER THE DIRECTION OF A PROFESSIONAL ENGINEER OR BY AN AABC OR NEBB CERTIFIED TEST AND BALANCE CONTRACTOR EMPLOYED BY THE CONSTRUCTION MANAGER. TEST AND BALANCE SHALL BE COMPLETED PRIOR TO SUBSTANTIAL COMPLETION. THE TEST AND BALANCE SHALL BE INCLUDED IN CONTRACTOR'S SCOPE OF WORK.

36. THE OWNER RESERVES THE RIGHT TO PROVIDE VERIFICATION OF THE TEST AND BALANCE REPORTS AND SUCH VERIFICATION SHALL BE BY A SECOND INDEPENDENT BALANCER. REPORTS FOUND TO BE INACCURATE WILL BE DISALLOWED AND THE BALANCER WILL BE REQUIRED TO REPEAT OPERATIONS UNDER THE SUPERVISION OF THE SECOND INDEPENDENT BALANCER UNTIL ACCURATE REPORTS ARE COMPLETED AND AGREED UPON. THE COST OF INITIAL CHECKING WILL BE BY THE CONTRACTOR, UNLESS THE INITIAL REPORT IS FOUND TO BE INACCURATE AND/OR INCOMPLETE. IN SUCH CASE, THE COSTS OF THE VERIFICATION TEST AND BALANCE AND ALL SUBSEQUENT COSTS OF SUPERVISION IN ORDER TO SECURE ACCEPTABLE REPORTS WILL BE

BY THE BALANCER.

Consultant ● Seal/Signature

Sheet Title:

Project Number:

2022-538

Scale:3 8''

File Name

Drawn By:

Checked By

AR

CH

ITE

CT

UR

E

PL

AN

NI

NG

IN

TE

RI

OR

D

ES

IG

N

SP

AC

E

PL

AN

NI

NG

Issue Date:09/18/2023 Project Status:

100% CONSTRUCTION DOCUMENTS

PR

IN

TE

D

ON

Client Information

ADCARCHITECTURAL DESIGN COLLABORATIVE

Architect ● Seal/Signature

Issue

Project Documents for:

Date Issue Description

Project:

Check By

945 N. PENNSYLVANIA AVENUE

WINTER PARK, FLORIDA 32789

OFFICE: (407) 629-1188

FAX: (407) 388-1220

WWW. ADCINTERNATIONAL.NET

MECHANICAL SYMBOL SPECIFICATIONS

M001

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text ALBERT JOSEPH COOPER III AR-0010460 STATE OF FLORIDA REGISTRATION NUMBER AA-C001315

AutoCAD SHX Text 2022-538

AutoCAD SHX Text

AutoCAD SHX Text 09/18/2023

AutoCAD SHX Text

100% CONSTRUCTION DOCUMENTS

AutoCAD SHX Text OCCC S CONCOURSE COMMAND CENTRAL ALTERATION 9800 INTERNATIONAL DRIVE ORLANDO, FL 32819

166 CFM

(TYP.3)

METASYS

CONTROL

PANEL

T VA

V-

B x8

10x6 x8 x8

1 T

VAV-C

14x6 x6

8Ø

20x10

1. RELOCATE EXITING THERMOSTATS AS REQUIRED. SEE RENOVATION PLANS

FOR NEW LOCATIONS.

2. REMAIN EXISTING DIFFUSERS AS REQUIRED

3. RELOCATE EXISTING CONTROL PANEL AS REQUIRED. CONTRACTOR TO FIELD

VERIFY NEW LOCATION AND COORDINATE WITH WITH EXISTING FURNITURE

AND EQUIPMENT.

PLAN KEY NOTES:#

GENERAL NOTES:

A. REFER TO SHEETS M001 AND M002 FOR MECHANICAL GENERAL NOTES AND

SYMBOLS LEGEND.

B. COORDINATE WORK SCHEDULE WITH PROJECT MANAGER. DISRUPTION OF

COOLING TO THE ADJACENT SPACES OR CAMPUS IS NOT ALLOWED.

C. DRAWINGS ARE DIAGRAMMATIC AND REPRESENT THE GENERAL LAYOUT OF

MECHANICAL COMPONENTS, FOR EXACT BUILDING DIMENSIONS SEE

ARCHITECTURAL AND STRUCTURAL DRAWINGS.

D. COORDINATE DUCTWORK ROUTING WITH ALL TRADES.

E. LOCATE EQUIPMENT SO THAT MANUFACTURERS SERVICE CLEARANCES ARE

MAINTAINED.

F. COORDINATE WITH ELECTRICAL CONTRACTOR LOCATION OF DISCONNECTS. DO

NOT BLOCK SERVICE CLEARANCE TO EQUIPMENT.

G. DUCTWORK SHALL REMAIN SEALED DURING CONSTRUCTION. .IF DUCTWORK IS

LEFT UNCOVERED DURING CONSTRUCTION, CONTRACTOR WILL BE REQUIRED

TO CLEAN ALL DUCTWORK PRIOR TO UNIT START-UP.

H. EXISTING DUCTWORK IS SHOWN AS REFERENCE ONLY, AND FOR TEST AND

BALANCE PURPOSE.

I. CONTRACTOR SHALL SEAL ALL WALL PENETRATIONS.

Consultant ● Seal/Signature

Sheet Title:

Project Number:

2022-538

Scale:3 8''

File Name

Drawn By:

Checked By

AR

CH

IT

EC

TU

RE

PL

AN

NI

NG

IN

TE

RI

OR

D

ES

IG

N

SP

AC

E

PL

AN

NI

NG

Issue Date:09/18/2023

Project Status:

100% CONSTRUCTION DOCUMENTS

PR

IN

TE

D

ON

Client Information

ADCARCHITECTURAL DESIGN COLLABORATIVE

Architect ● Seal/Signature

Issue

Project Documents for:

Date Issue Description

Project:

Check By

945 N. PENNSYLVANIA AVENUE

WINTER PARK, FLORIDA 32789

OFFICE: (407) 629-1188

FAX: (407) 388-1220

WWW. ADCINTERNATIONAL.NET

MECHANICAL DEMO FLOOR PLAN

MD201

N

00 8' 16'4'SCALE: 3/8"=1'-0"

MECHANICAL DEMO FLOOR PLAN

AutoCAD SHX Text

CONSOLE

AutoCAD SHX Text

ROOM

AutoCAD SHX Text 6-113.7

AutoCAD SHX Text

EQUIP.

AutoCAD SHX Text

ROOM

AutoCAD SHX Text 6-113.5

AutoCAD SHX Text ALBERT JOSEPH COOPER III AR-0010460 STATE OF FLORIDA REGISTRATION NUMBER AA-C001315

AutoCAD SHX Text 2022-538

AutoCAD SHX Text

AutoCAD SHX Text 09/18/2023

AutoCAD SHX Text

100% CONSTRUCTION DOCUMENTS

174 CFM

240 CFM

(TPY.3)

VA

V-

B

VAV-C

x8

10x6

14x6 x6

8Ø x8 x8

20x10

METASYS

CONTROL

PANEL

T

T

(E)

6"Ø

6"Ø

GENERAL NOTES:

PLAN KEY NOTES:

A. REFER TO SHEETS M001 AND M002 FOR MECHANICAL GENERAL NOTES AND

SYMBOLS LEGEND.

B. COORDINATE WORK SCHEDULE WITH PROJECT MANAGER. DISRUPTION OF

COOLING TO THE ADJACENT SPACES OR CAMPUS IS NOT ALLOWED.

C. DRAWINGS ARE DIAGRAMMATIC AND REPRESENT THE GENERAL LAYOUT OF

MECHANICAL COMPONENTS, FOR EXACT BUILDING DIMENSIONS SEE

ARCHITECTURAL AND STRUCTURAL DRAWINGS.

D. COORDINATE DUCTWORK ROUTING WITH ALL TRADES.

E. LOCATE EQUIPMENT SO THAT MANUFACTURERS SERVICE CLEARANCES ARE

MAINTAINED.

F. COORDINATE WITH ELECTRICAL CONTRACTOR LOCATION OF DISCONNECTS. DO

NOT BLOCK SERVICE CLEARANCE TO EQUIPMENT.

G. DUCTWORK SHALL REMAIN SEALED DURING CONSTRUCTION. .IF DUCTWORK IS

LEFT UNCOVERED DURING CONSTRUCTION, CONTRACTOR WILL BE REQUIRED

TO CLEAN ALL DUCTWORK PRIOR TO UNIT START-UP.

H. EXISTING DUCTWORK IS SHOWN AS REFERENCE ONLY, AND FOR TEST AND

BALANCE PURPOSE.

I. CONTRACTOR SHALL SEAL ALL WALL PENETRATIONS.

1. REMAIN EXISTING SUPPLY DIFFUSERS AND BALANCE TO CFM VALUE INDICATED.

2. RELOCATED EXISTING THERMOSTAT AS REQUIRED.

3. RELOCATE EXISTING CONTROL PANEL. PROPOSED LOCATION IS APPROXIMATE.

CONTRACTOR TO FIELD VERIFY NEW LOCATION AND COORDINATE WITH EXISTING

FURNITURE AND EQUIPMENT.

Consultant ● Seal/Signature

Sheet Title:

Project Number:

2022-538

Scale:3 8''

File Name

Drawn By:

Checked By

AR

CH

IT

EC

TU

RE

PL

AN

NI

NG

IN

TE

RI

OR

D

ES

IG

N

SP

AC

E

PL

AN

NI

NG

Issue Date:09/18/2023

Project Status:

100% CONSTRUCTION DOCUMENTS

PR

IN

TE

D

ON

Client Information

ADCARCHITECTURAL DESIGN COLLABORATIVE

Architect ● Seal/Signature

Issue

Project Documents for:

Date Issue Description

Project:

Check By

945 N. PENNSYLVANIA AVENUE

WINTER PARK, FLORIDA 32789

OFFICE: (407) 629-1188

FAX: (407) 388-1220

WWW. ADCINTERNATIONAL.NET

MECHANICAL FLOOR PLAN PROPOSED

M201

N

00 8' 16'4'SCALE: 3/8"=1'-0"

MECHANICAL FLOOR PLAN PROPOSED

AutoCAD SHX Text

CONSOLE

AutoCAD SHX Text

ROOM

AutoCAD SHX Text 6-113.7

AutoCAD SHX Text

EQUIP.

AutoCAD SHX Text

ROOM

AutoCAD SHX Text 6-113.5

AutoCAD SHX Text ALBERT JOSEPH COOPER III AR-0010460 STATE OF FLORIDA REGISTRATION NUMBER AA-C001315

AutoCAD SHX Text 2022-538

AutoCAD SHX Text

AutoCAD SHX Text 09/18/2023

AutoCAD SHX Text

100% CONSTRUCTION DOCUMENTS

Consultant ● Seal/Signature

Sheet Title:

Project Number:

2022-538

Scale:3 8''

File Name

Drawn By:

Checked By

AR

CH

ITE

CT

UR

E

PL

AN

NI

NG

IN

TE

RI

OR

D

ES

IG

N

SP

AC

E

PL

AN

NI

NG

Issue Date:09/18/2023 Project Status:

100% CONSTRUCTION DOCUMENTS

PR

IN

TE

D

ON

Client Information

ADCARCHITECTURAL DESIGN COLLABORATIVE

Architect ● Seal/Signature

Issue

Project Documents for:

Date Issue Description

Project:

Check By

945 N. PENNSYLVANIA AVENUE

WINTER PARK, FLORIDA 32789

OFFICE: (407) 629-1188

FAX: (407) 388-1220

WWW. ADCINTERNATIONAL.NET

MECHANICAL DETAILS

M801

DUCT TO SUPPLY DIFFUSER CONN. DETAIL

CEILING

SUPPLY AIR DUCT

SECURE FLEX DUCT TO

DIFFUSER NECK USING

STAINLESS STEEL CLAMP OR

PANDUIT STRAP

UL 181, CLASS 1 FLEX DUCT

MAXIMUM LENGTH 7 FEET

2" WIDE GALVANIZED STEEL

FLEX DUCT SUPPORT STRAP

SPIN IN FITTING W/MANUAL

VOLUME DAMPER

SEAL FLEX TO DUCT USING

TIMA APPROVED DUCT TAPE

OR GLASS FABRIC & MASTIC

STAINLESS STEEL BAND

OR PANDUIT STRAP

2" BATT INSULATION WITH FOIL

VAPOR BARRIER ON OUTSIDE

SEAL INSULATION TO FLEX DUCT AND

DIFFUSER USING TIMA APPROVED DUCT

TAPE TO MAINTAIN VAPOR BARRIER

NOT TO SCALE

DIFFUSER- SEE PLAN AND

SCHEDULE FOR TYPE

SUPPLY DUCT

SPIN-IN FITTING

WITH DAMPER INSULATED ROUND FLEXIBLE

DUCT (MAX. 6'-0" LONG) SIZE

TO MATCH DIFFUSER NECK.

INSULATION

CEILING DIFFUSERCEILING

ROUND METAL DUCT

(EXTERNAL INSULATION)

CEILING DIFFUSER RUNOUT DETAIL

NOT TO SCALE

M8.01

60" MAX

HANGER STRAPS DUCT

HANGER STRAPS

DUCT HANGING DETAIL

NOT TO SCALE

SUPPORT BY EXISTING

STRUCTURE

AutoCAD SHX Text ALBERT JOSEPH COOPER III AR-0010460 STATE OF FLORIDA REGISTRATION NUMBER AA-C001315

AutoCAD SHX Text 2022-538

AutoCAD SHX Text

AutoCAD SHX Text 09/18/2023

AutoCAD SHX Text

100% CONSTRUCTION DOCUMENTS

TV

TV

LIGHTING FIXTURES

POWER DEVICES

SINGLE RECEPTACLE

JUNCTION BOX

DUPLEX RECEPTACLE

DISCONNECT SWITCH

DOOR BELL PUSH BUTTON

EQUIPMENT CONNECTION

SPECIAL PURPOSE RECEPTACLE

DOUBLE DUPLEX RECEPTACLE

MOTOR STARTER

SHUNT TRIP. MTD. AT 6'-5" AFF/AFG TO TOP OF ENCLOSURE

PHOTOCELL

DOOR BELL

TIMECLOCK

TRANSFORMER

DUPLEX RECEPTACLE, GROUND FAULT, ABOVE COUNTER

DUPLEX RECEPTACLE, GROUND FAULT

SINGLE 250V NON-LOCKING TYPE RECEPTACLE

ABOVE COUNTER DUPLEX RECEPTACLE

DUPLEX RECEPTACLE, HALF SWITCHED

MOTOR

120/208V PANELBOARD, SURFACE MOUNT

277/480V PANELBOARD, SURFACE MOUNT

POWER/DATA POLE

PULL BOX

CEILING MOUNTED RECEPTACLE

RECESSED FLOOR RECEPTACLE

FLOOR MOUNTED JUNCTION BOX

120/208V PANELBOARD, RECESSED

277/480V PANELBOARD, RECESSED

FEEDER OR BRANCH CIRCUIT CONCEALED IN WALL,

CEILING OR FLOOR

STARTER/DISCONNECT SWITCH

GENERATOR

CLOCK

LOCKBOX

DUPLEX RECEPTACLE, GROUND FAULT

WITH CAST ALUMINUM PADLOCKABLE (1

4" HASP) WEATHERPROOF

"IN USE" COVER. TAYMAC MX3200 OR EQUAL

DUPLEX RECEPTACLE, GROUND FAULT

LOCATE WITHIN ELECTRIC WATER COOLER PER

MANUFACTURER'S INSTRUCTIONS

DUPLEX RECEPTACLE FOR COMPUTER WORKSTATION

DUPLEX RECEPTACLE FOR TV LOCATED AT 18"AFF. LOCATE IN

COMMON BOX WITH CCTV

DUPLEX RECEPTACLE FOR TV LOCATED AT 84" AFF UNLESS

NOTED OTHERWISE.

AIR TERMINAL (ALUMINUM CLASS 1 MIN).

ROOFTOP MAIN CONDUCTOR, RUN EXPOSED ACROSS

ROOF.

DOWN CONDUCTOR, RUN CONCEALED IN STRUCTURE -

COPPER CLASS 1

COPPER-CLAD DRIVEN GROUND ROD AND TEST WELL.

SEE SPECIFICATIONS.

BOLTED 3-WAY SPLICE

BOLTED 4-WAY SPLICE

GROUND BUS BAR

GROUND ROD WITH TEST INSPECTION WELL. SEE

SPECIFICATIONS.

PIR-WALL SWITCH DECORATOR MOTION SENSOR, 120/277 VAC,

800/1200W. WATTSTOPPER PW-100 OR EQUAL.

DUAL ULTRASONIC/PIR-WALL SWITCH DECORATOR MOTION SENSOR,

120/277VAC, 800/1200W. WATTSTOPPER DW-100 OR EQUAL.

*DUAL ULTRASONIC/PIR-CEILING MOUNT SENSOR, 24 VDC/VAC,

35mA. WATTSTOPPER DT-305 OR EQUAL.

*DUAL ULTRASONIC/PIR-WALL MOUNT SENSOR, 24 VAC/VDC, 35mA.

WATTSTOPPER DT-205 OR EQUAL.

POWER PACK 120/277 VAC; 20 AMPS, 225mA SECONDARY.

WATTSTOPPER BZ-250 OR EQUAL.

*PIR-WALL MOUNT SENSOR, LOW TEMP, 24 VDC/AC, 20mA.

WATTSTOPPER CB-100 OR EQUAL.

*PIR-CEILING MOUNT SENSOR 24 VDC/VAC, 11mA, WATTSTOPPER

CI-205 OR EQUAL.

QUAD RECEPTACLE, GROUND FAULT

WITH CAST ALUMINUM PADLOCKABLE (1

4" HASP) WEATHERPROOF "IN USE"

COVER. TAYMAC MX 6200 OR EQUAL.

TRACK FIXTURE

CEILING MOUNTED RECESSED, DOWN LIGHT

EMERGENCY LIGHT FIXTURE

2'x4' FIXTURE

1'x4' FIXTURE

2'x2' FIXTURE

SURFACE MOUNTED LIGHTING FIXTURE

2'x4' FIXTURE, BATTERY/EMERGENCY

2'x2' FIXTURE, BATTERY/EMERGENCY

1'x4' FIXTURE, BATTERY/EMERGENCY

FLOOD LIGHT FIXTURE

BOLLARD OR PENDANT LIGHT FIXTURE

POWER DISTRIBUTION

LIGHTING CONTROL DEVICES

LIGHTNING PROTECTION

MISCELLANEOUS SYMBOL LEGEND

ABBREVIATIONS

AMPERES

ABOVE FINISHED FLOOR

ABOVE FINISHED GRADE

BELOW FINISHED GRADE

ELECTRIC UNIT HEATER

ELECTRIC WATER COOLER

ELECTRIC WATER HEATER

ELECTRICAL METALLIC TUBING

BELOW FINISHED CEILING

EWH

FLUOR

FA

EXIST

EXH

EQUIP

EWC

EUH

EMT

EF

FLUORESCENT

FIRE ALARM

EXHAUST

EXISTING

EXHAUST FAN

EQUIPMENT

CLG

DISC

DWG

EA

CU

CL

CAB

CKT

BFG

CEILING

CENTERLINE

DISCONNECT(ING)

DRAWING(S)

EACH

COPPER

CABINET

CIRCUIT

CONDUIT

AFG

BFC

A

AFF

NATIONAL ELECTRICAL CODE

POLYVINYL CHLORIDE

UNLESS OTHERWISE NOTED

XFMR

V

WP

VA

TEL

UON

TRANSFORMER

TELEPHONE

VOLT-AMPERES

WEATHER PROOF

VOLTS

PVC

PNL

REC

NEC

MTR

MTG

MTD

MISC

MIN

RECEPTACLE

PANEL

MINIMUM

MISCELLANEOUS

MOUNTED

MOUNTING

MOTOR

HEATING/VENTILATING/

KILO-VOLTS-AMPERES

KILO-WATT-HOURS

MOTOR CONTROL CENTERMCC

MH

MFR

MAX

LTG

kVA kWH kW kV

JB

METAL HALIDE

LIGHTING

MANUFACTURER

MAXIMUM

JUNCTION BOX

KILO-VOLTS

KILO-WATTS

HVAC

HV

INC

HP HORSEPOWER

HIGH VOLTAGE

INCANDESCENT

FLA FULL LOAD AMPERES

ABOVE FINISHED CEILINGAFC

W WATTS

TYP TYPICAL

GFCI GROUND FAULT CIRCUIT

INTERRUPTER

CURRENT TRANSFORMERSCT's

KILO-VOLTS-AMPERES REACTIVEkVAR

RGS RIGID GALVANIZED STEEL

C m METER mm MILLIMETER

AIC AMPERES INTERUPTING

CAPACITY

MCB MAIN CIRCUIT BREAKER

MCP MOTOR CIRCUIT PROTECTOR

AIR CONDITIONING

HAND-OFF-AUTOMATIC

HIGH INTENSITY DISCHARGE

HIGH PRESSURE SODIUM

HID

HOA

HPS

GND

HGT

GROUND

HEIGHT

GFP GROUND FAULT PROTECTION

VFD VARIABLE FREQUENCY DRIVE

AMERICAN WIRE GAUGEAWG

PULL STATION INSIDEPSI

EXP EXPLOSION PROOFAUDIO ENHANCEMENTAE

1R1-1,3,5

1M1-1:3:5

1R1-1

1M1-1:3

1R1-1,3

4' WALL MOUNT FIXTURE

4' WALL MOUNT FIXTURE, EMERGENCY

CEILING MOUNTED RECESSED, EMERGENCY DOWN LIGHT

BOLLARD OR PENDANT LUMINAIRE, EMERGENCY

WALL MOUNTED SCONCE FIXTURE, BATTERY/EMERGENCY

POLE MOUNTED LUMINAIRE

SINGLE POLE MOUNT LUMINAIRE-RECTANGLES INDICATE

NUMBER OF FIXTURES

HOMERUN CONSISTING OF ONE SINGLE-PHASE, 1-POLE CIRCUIT, SEE

SPECIFICATIONS AND/OR FEEDER SCHEDULES FOR WIRE SIZES.

PANELBOARD AND CIRCUIT DESIGNATION ARE INDICATED.

HOMERUN CONSISTING OF THREE SINGLE-PHASE CIRCUITS: SEE

SPECIFICATIONS AND/OR FEEDER SCHEDULES FOR WIRE SIZES.

PANELBOARD AND CIRCUIT DESIGNATIONS ARE INDICATED.

HOMERUN CONSISTING OF ONE THREE-PHASE CIRCUITS: SEE

SPECIFICATIONS AND/OR FEEDER SCHEDULES FOR WIRE SIZES.

PANELBOARD AND CIRCUIT DESIGNATIONS ARE INDICATED.

HOMERUN CONSISTING OF ONE SINGLE-PHASE, 2-P0LE CIRCUIT:

SEE SPECIFICATIONS AND/OR FEEDER SCHEDULES FOR WIRE

SIZES. PANELBOARD AND CIRCUIT DESIGNATIONS ARE INDICATED.

HOMERUN CONSISTING OF TWO SINGLE-PHASE CIRCUITS: SEE

SPECIFICATIONS AND/OR FEEDER SCHEDULES FOR WIRE SIZES.

PANELBOARD AND CIRCUIT DESIGNATION ARE INDICATED.

E200

TITLE

SCALE: DETAIL TITLE REFERENCE

DETAIL NUMBER

SHEET NUMBER WHERE DETAIL IS REFERENCED

ADDITIONAL SHEET REFERENCES

E200

DETAIL NUMBER

SHEET NUMBER TO WHERE DETAIL IS REFERENCED

XX.XX

XX

WP

WP

EWC

CEILING MOUNTED RECESSED, WALL WASHER (ARROW

INDICATES DIRECTION OF WASH)

SINGLE FACE EXIT LIGHT FIXTURE ARROW INDICATES

DIRECTION OF EGRESS

DOUBLE FACE EXIT LIGHT FIXTURE ARROW INDICATES

DIRECTION OF EGRESS

POLE MOUNTED SITE LIGHTING FIXTURE RECTANGLES INDICATE

NUMBER OF FIXTURES

PC

TC

C

QUAD RECEPTACLE, GROUND FAULT

C

POWER POLE

J

J

PB

C

ST

DB

G

ALUMINUMAL

P

PD

PP

T

DN

SPD SURGE PROTECTION DEVICE, SEE SPECIFICATIONS.

SPD SURGE PROTECTION DEVICE

ECB

MMS

ENCLOSED CIRCUIT BREAKER

MANUAL MOTOR STARTER SWITCH

LT

R9

PP

W

CI

DT

S

D1

C

NOTIFICATION APPLIANCE CIRCUIT

*ULTRASONIC-CEILING CORRIDOR MOTION SENSOR, 24 VDC/VAC,

40mA. WATTSTOPPER WT-2250 OR EQUAL.

NAC

SWITCH, 1 POLE, LETTER INDICATES SWITCHLEG CONTROLLED.

SWITCH, KEYSWITCH

S3 4S

S

PS

2S

SWITCH

a

SWITCH, 2 POLE

S

SWITCH, 3-WAY

SWITCH, 4-WAY

KS

SWITCH - PILOT LIGHT

MS

S

MOTOR RATED SWITCH

S

SWITCH, 3-WAY, LETTER INDICATES SWITCHLEG CONTROLLED

SWITCH, KEYSWITCH, 3-WAY

NIGHT LIGHT, UNSWITCHEDNL

*FOR LOW VOLTAGE OCCUPANCY SENSORS, PROVIDE POWER

PACK(S) 120/277 VAC; 20 AMPS, 225mA SECONDARY AS NEEDED FOR

ZONE/AREA CONTROL. WATTSTOPPER BZ-250 OR EQUAL.

SWITCHES

SWITCH - LINE VOLTAGE TIMER, 120/277 VAC. WATTSTOPPER

TS-400 OR EQUAL.

DUAL ULTRASONIC/PIR-DUAL RELAY WALL SWITCH DECORATOR

MOTION SENSOR, 120/277VAC, 800/1200W. WATTSTOPPER DW-200 OR

EQUAL.

D2

S SWITCH, EXPLOSION PROOF

QUAD RECEPTACLE FOR COMPUTER WORKSTATION

C

4' STRIP FIXTURE

4' STRIP FIXTURE, BATTERY/EMERGENCY

4' STRIP FIXTURE, WALL MOUNTED

4' STRIP FIXTURE, WALL MOUNTED,

BATTERY/EMERGENCY

3a

3K

EXP

LB

VARIABLE FREQUENCY DRIVEVFD

UL 924 LISTED FAILSAFE EMERGENCY SWITCHING RELAY, LVS EPC-A

OR EQUAL. LOWER CASE LETTER NEXT TO DEVICE INDICATES

SWITCHLEG CONTROLLED.

LVS

S SWITCH, LOW VOLTAGE MOMENTARYL

TS

SWP

SWITCH, WEATHERPROOF

LIGHTING CONTACTORLC

Consultant ● Seal/Signature

Sheet Title:

Project Number:

2022-538

Scale:38''

File Name

Drawn By:

Checked By

AR

CH

ITE

CT

UR

E

PL

AN

NI

NG

IN

TE

RI

OR

D

ES

IG

N

SP

AC

E

PL

AN

NI

NG

Issue Date:09/18/2023 Project Status:

100% CONSTRUCTION DOCUMENTS

PR

IN

TE

D

ON

Client Information

ADCARCHITECTURAL DESIGN COLLABORATIVE

Architect ● Seal/Signature

Issue

Project Documents for:

Date Issue Description

Project:

Check By

945 N. PENNSYLVANIA AVENUE

WINTER PARK, FLORIDA 32789

OFFICE: (407) 629-1188

FAX: (407) 388-1220

WWW. ADCINTERNATIONAL.NET

2022-538

ELECTRICAL SYMBOL SPECIFICATIONS

E001

AutoCAD SHX Text ALBERT JOSEPH COOPER III AR-0010460 STATE OF FLORIDA REGISTRATION NUMBER AA-C001315

AutoCAD SHX Text

AutoCAD SHX Text 09/18/2023

AutoCAD SHX Text

100% CONSTRUCTION DOCUMENTS

WAP

EXEX

EX

EX

EX

EX

EX

EX

1 1 1

1 1

1 1

GENERAL NOTES:

a. REFER TO SYMBOL LEGEND ON SHEET E001.

b. REFER TO BOOK SPECIFICATIONS.

c. REFER TO ARCHITECTURAL INTERIOR ELEVATIONS TO COORDINATE

EXACT PLACEMENT OF ALL DEVICES, EQUIPMENT, FIXTURES,

SWITCHES AND OUTLETS.

d. ITEMS SCREENED ARE EXISTING TO REMAIN. ITEMS IN FULL PEN

WEIGHT SHALL BE DEMOLISHED

PLAN KEY NOTES:

1. CONTRACTOR TO REMOVE ALL DEVICES, WIRING, AND CONDUIT

BACK TO THE SOURCE.

Consultant ● Seal/Signature

Sheet Title:

Project Number:

2022-538

Scale:38''

File Name

Drawn By:

Checked By

AR

CH

ITE

CT

UR

E

PL

AN

NI

NG

IN

TE

RI

OR

D

ES

IG

N

SP

AC

E

PL

AN

NI

NG

Issue Date:09/18/2023 Project Status:

100% CONSTRUCTION DOCUMENTS

PR

IN

TE

D

ON

Client Information

ADCARCHITECTURAL DESIGN COLLABORATIVE

Architect ● Seal/Signature

Issue

Project Documents for:

Date Issue Description

Project:

Check By

945 N. PENNSYLVANIA AVENUE

WINTER PARK, FLORIDA 32789

OFFICE: (407) 629-1188

FAX: (407) 388-1220

WWW. ADCINTERNATIONAL.NET

2022-538

LIGHTING DEMO PLAN

ED201

N

00 8' 16'4'SCALE: 3/8"=1'-0"

LIGHTING DEMO PLAN

AutoCAD SHX Text ALBERT JOSEPH COOPER III AR-0010460 STATE OF FLORIDA REGISTRATION NUMBER AA-C001315

AutoCAD SHX Text

AutoCAD SHX Text 09/18/2023

AutoCAD SHX Text

100% CONSTRUCTION DOCUMENTS

EX EX

EX

EX

EX

EX

EXEXEX

EX

EX

J

1AELC-13,15

1AELC-11

1AELC-17

1AELC-25

1AELC-19

1AELC-21

1AELC-23

F

F

F S

F

2 2

GENERAL NOTES:

a. REFER TO SYMBOL LEGEND ON SHEET E001.

b. REFER TO BOOK SPECIFICATIONS.

c. REFER TO ARCHITECTURAL INTERIOR ELEVATIONS TO COORDINATE

EXACT PLACEMENT OF ALL DEVICES, EQUIPMENT, FIXTURES,

SWITCHES AND OUTLETS.

d. ITEMS SCREENED ARE EXISTING TO REMAIN. ITEMS IN FULL PEN

WEIGHT SHALL BE DEMOLISHED

PLAN KEY NOTES:

1. CONTRACTOR TO REMOVE EXISTING FIRE ALARM DEVICES

CONTRACTOR TO PROTECT EXISTING FIRE ALARM CIRCUIT TO BE

REUSED.

2. CONTRACTOR TO REMOVE ALL DEVICES, WIRING, AND CONDUIT

BACK TO THE SOURCE.

Consultant ● Seal/Signature

Sheet Title:

Project Number:

2022-538

Scale:38''

File Name

Drawn By:

Checked By

AR

CH

ITE

CT

UR

E

PL

AN

NI

NG

IN

TE

RI

OR

D

ES

IG

N

SP

AC

E

PL

AN

NI

NG

Issue Date:09/18/2023 Project Status:

100% CONSTRUCTION DOCUMENTS

PR

IN

TE

D

ON

Client Information

ADCARCHITECTURAL DESIGN COLLABORATIVE

Architect ● Seal/Signature

Issue

Project Documents for:

Date Issue Description

Project:

Check By

945 N. PENNSYLVANIA AVENUE

WINTER PARK, FLORIDA 32789

OFFICE: (407) 629-1188

FAX: (407) 388-1220

WWW. ADCINTERNATIONAL.NET

2022-538

POWER DEMO PLAN

ED301

N

00 8' 16'4'SCALE: 3/8"=1'-0"

POWER DEMO PLAN

AutoCAD SHX Text

CONSOLE

AutoCAD SHX Text

ROOM

AutoCAD SHX Text 6-113.7

AutoCAD SHX Text

EQUIP.

AutoCAD SHX Text

ROOM

AutoCAD SHX Text 6-113.5

AutoCAD SHX Text ALBERT JOSEPH COOPER III AR-0010460 STATE OF FLORIDA REGISTRATION NUMBER AA-C001315

AutoCAD SHX Text

AutoCAD SHX Text 09/18/2023

AutoCAD SHX Text

100% CONSTRUCTION DOCUMENTS

MATCH

LINE

MATCH

LINE

1APC

1AEHC

1AEPC

1AELC

ELECTRICAL ROOM

Consultant ● Seal/Signature

Sheet Title:

Project Number:

2022-538

Scale:38''

File Name

Drawn By:

Checked By

AR

CH

ITE

CT

UR

E

PL

AN

NI

NG

IN

TE

RI

OR

D

ES

IG

N

SP

AC

E

PL

AN

NI

NG

Issue Date:09/18/2023 Project Status:

100% CONSTRUCTION DOCUMENTS

PR

IN

TE

D

ON

Client Information

ADCARCHITECTURAL DESIGN COLLABORATIVE

Architect ● Seal/Signature

Issue

Project Documents for:

Date Issue Description

Project:

Check By

945 N. PENNSYLVANIA AVENUE

WINTER PARK, FLORIDA 32789

OFFICE: (407) 629-1188

FAX: (407) 388-1220

WWW. ADCINTERNATIONAL.NET

2022-538

EXHIBIT LEVEL 1

E101

N

00 8' 16'4'SCALE: 3/8"=1'-0"

EXHIBIT LEVEL 1

AutoCAD SHX Text ALBERT JOSEPH COOPER III AR-0010460 STATE OF FLORIDA REGISTRATION NUMBER AA-C001315

AutoCAD SHX Text

AutoCAD SHX Text 09/18/2023

AutoCAD SHX Text

100% CONSTRUCTION DOCUMENTS

WAP

EXEX

EX

EX

EX

EX

EX

EX

S

3S

A

AA

A

A

A

A

1 1

A

A

A

A

GENERAL NOTES:

a. REFER TO SYMBOL LEGEND ON SHEET E001.

b. REFER TO BOOK SPECIFICATIONS.

c. REFER TO ARCHITECTURAL INTERIOR ELEVATIONS TO COORDINATE

EXACT PLACEMENT OF ALL DEVICES, EQUIPMENT, FIXTURES,

SWITCHES AND OUTLETS.

d. ALL COMPUTER CIRCUITS SHALL HAVE DEDICATED NEUTRAL FROM

LOAD TO SOURCE EQUIPMENT.

e. IF CIRCUITS ARE COMBINED AND RUN AS MULTI-WIRE BRANCH

CIRCUITS SHARING A COMMON NEUTRAL, THEN EACH UNGROUNDED

CONDUCTOR MUST BE DISCONNECTED SIMULTANEOUSLY BY A

COMMON TRIP CIRCUIT BREAKER. CONTRACTOR MAY, AT THEIR

OPTION, PROVIDE EITHER COMMON TRIP MULTI-POLE CIRCUIT

BREAKERS OR UTILIZE MANUFACTURERS LISTED HANDLE TIES IN

ORDER TO PROVIDE THE SIMULTANEOUS TRIP. THESE DEVICES ARE

NOT SHOWN IN THE PANEL SCHEDULES AND MUST BE PROVIDED BY

THIS SCOPE OF WORK. NO MORE THAN 3 CIRCUITS MAY BE

COMBINED IN A SINGLE RACEWAY WITHOUT PRIOR APPROVAL BY

THE ENGINEER.

f. CONTRACTOR SHALL PERFORM CIRCUIT TRACE ON ALL BRANCH

CIRCUITS IN PANEL BEING REPLACED AND PROVIDE AN UPDATED

TYPEWRITTEN PANEL SCHEDULE IDENTIFYING CIRCUITS FED AND

LOCATION AND/OR ROOM NUMBER.

g. CONTRACTOR TO CONFIRM THAT THERE IS A GROUND CONDUCTOR

FOR EACH LOAD OR THAT THE CONDUIT PATH GROUND IS

CONTINUOUS FOR EACH LOAD.

h. CONTRACTOR TO CHECK PHASE ROTATION PRIOR TO

DISCONNECTION AND AFTER RECONNECTION OF POWER.

i. CONTRACTOR TO IDENTIFY CONDUITS EXITING PANEL WITH CIRCUIT

NUMBER INFORMATION.

j. ENSURE ALL WIRES ARE TAGGED PER IDENTIFICATION

SPECIFICATION.

PLAN KEY NOTES:

1. CONTRACTOR TO REUSE EXISTING LIGHTING CIRCUIT. EXTEND

EXISTING CIRCUIT (CONDUIT AND WIRING AS NEEDED). CONTRACTOR

TO REPROGRAM EXISTING LIGHTING SYSTEM COMBINING THE TWO

ROOMS. ALL FIXTURES SHALL BE CAPABLE OF DIMMING

CONTRACTOR TO PROGRAM DIMMING.

Consultant ● Seal/Signature

Sheet Title:

Project Number:

2022-538

Scale:38''

File Name

Drawn By:

Checked By

AR

CH

ITE

CT

UR

E

PL

AN

NI

NG

IN

TE

RI

OR

D

ES

IG

N

SP

AC

E

PL

AN

NI

NG

Issue Date:09/18/2023 Project Status:

100% CONSTRUCTION DOCUMENTS

PR

IN

TE

D

ON

Client Information

ADCARCHITECTURAL DESIGN COLLABORATIVE

Architect ● Seal/Signature

Issue

Project Documents for:

Date Issue Description

Project:

Check By

945 N. PENNSYLVANIA AVENUE

WINTER PARK, FLORIDA 32789

OFFICE: (407) 629-1188

FAX: (407) 388-1220

WWW. ADCINTERNATIONAL.NET

2022-538

LIGHTING PLAN RCP

E201

N

00 8' 16'4'SCALE: 3/8"=1'-0"

LIGHTING PLAN RCP

AutoCAD SHX Text ALBERT JOSEPH COOPER III AR-0010460 STATE OF FLORIDA REGISTRATION NUMBER AA-C001315

AutoCAD SHX Text

AutoCAD SHX Text 09/18/2023

AutoCAD SHX Text

100% CONSTRUCTION DOCUMENTS

1AELC-13

1AELC-17

1AELC-25

1AELC-19

1AELC-21

1AELC-23

S4

S4

S4

S4

S4

S4

S4

S4

S4

S4

S4

S4

S4

1AELC-15

75CD S

J4

+68"

+68"

+68"

+68"

+58"

+58"

S4

1AELC-34

NEW IDF

CABINET

1AELC-36:38

GENERAL NOTES:

a. REFER TO SYMBOL LEGEND ON SHEET E001.

b. REFER TO BOOK SPECIFICATIONS.

c. REFER TO ARCHITECTURAL INTERIOR ELEVATIONS TO COORDINATE

EXACT PLACEMENT OF ALL DEVICES, EQUIPMENT, FIXTURES,

SWITCHES AND OUTLETS.

d. ALL COMPUTER CIRCUITS SHALL HAVE DEDICATED NEUTRAL FROM

LOAD TO SOURCE EQUIPMENT.

e. IF CIRCUITS ARE COMBINED AND RUN AS MULTI-WIRE BRANCH

CIRCUITS SHARING A COMMON NEUTRAL, THEN EACH UNGROUNDED

CONDUCTOR MUST BE DISCONNECTED SIMULTANEOUSLY BY A

COMMON TRIP CIRCUIT BREAKER. CONTRACTOR MAY, AT THEIR

OPTION, PROVIDE EITHER COMMON TRIP MULTI-POLE CIRCUIT

BREAKERS OR UTILIZE MANUFACTURERS LISTED HANDLE TIES IN

ORDER TO PROVIDE THE SIMULTANEOUS TRIP. THESE DEVICES ARE

NOT SHOWN IN THE PANEL SCHEDULES AND MUST BE PROVIDED BY

THIS SCOPE OF WORK. NO MORE THAN 3 CIRCUITS MAY BE

COMBINED IN A SINGLE RACEWAY WITHOUT PRIOR APPROVAL BY

THE ENGINEER.

f. CONTRACTOR SHALL PERFORM CIRCUIT TRACE ON ALL BRANCH

CIRCUITS IN PANEL BEING REPLACED AND PROVIDE AN UPDATED

TYPEWRITTEN PANEL SCHEDULE IDENTIFYING CIRCUITS FED AND

LOCATION AND/OR ROOM NUMBER.

g. CONTRACTOR TO CONFIRM THAT THERE IS A GROUND CONDUCTOR

FOR EACH LOAD OR THAT THE CONDUIT PATH GROUND IS

CONTINUOUS FOR EACH LOAD.

h. CONTRACTOR TO CHECK PHASE ROTATION PRIOR TO

DISCONNECTION AND AFTER RECONNECTION OF POWER.

i. CONTRACTOR TO IDENTIFY CONDUITS EXITING PANEL WITH CIRCUIT

NUMBER INFORMATION.

j. ENSURE ALL WIRES ARE TAGGED PER IDENTIFICATION

SPECIFICATION.

PLAN KEY NOTES:

1. CONTRACTOR TO PROVIDE AND INSTALL NEW CONDUIT AND WIRING

FOR POWER AND DATA FOR MONITORS. CONTRACTOR REFER TO

ARCHITECTURAL DRAWINGS FOR EXACT LOCATION AND HEIGHTS OF

MONITORS.

2. CONTRACTOR TO PROVIDE AND INSTALL NEW CONDUIT AND WIRING

FOR POWER AND DATA AT NEW CONTROL CONSOLE. ALL CONDUIT

TO BE INSTALLED ON EXISTING COLUMN UNTIL NEW CONSOLE

CABINET. CONTRACTOR TO INSTALL CONDUIT AND WIRING IN

CONSOLE SO THAT IT IS CONCEALED FROM VIEW.

3. CONTRACTOR TO CONNECT NEW FIRE ALARM DEVICES INTO

EXISTING CIRCUIT. CONTRACTOR TO PROVIDE ALL CONDUIT,WIRING,

AND FIRE ALARM DEVICES AS NEEDED.

4. CONTRACTOR TO INSTALL CONDUIT AND WIRING ON THE COLUMN

FOR THE POWER AND DATA TO THE CONSOLE.

5. PROVIDE AND INSTALL NEW IDF CABINET. CONTRACTOR TO INSTALL

FIBER TO NEAREST IDF CABINET.

Consultant ● Seal/Signature

Sheet Title:

Project Number:

2022-538

Scale:38''

File Name

Drawn By:

Checked By

AR

CH

ITE

CT

UR

E

PL

AN

NI

NG

IN

TE

RI

OR

D

ES

IG

N

SP

AC

E

PL

AN

NI

NG

Issue Date:09/18/2023 Project Status:

100% CONSTRUCTION DOCUMENTS

PR

IN

TE

D

ON

Client Information

ADCARCHITECTURAL DESIGN COLLABORATIVE

Architect ● Seal/Signature

Issue

Project Documents for:

Date Issue Description

Project:

Check By

945 N. PENNSYLVANIA AVENUE

WINTER PARK, FLORIDA 32789

OFFICE: (407) 629-1188

FAX: (407) 388-1220

WWW. ADCINTERNATIONAL.NET

2022-538

POWER PROPOSED PLAN

E301

N

00 8' 16'4'SCALE: 3/8"=1'-0"

POWER PROPOSED PLAN

AutoCAD SHX Text

CONSOLE

AutoCAD SHX Text

ROOM

AutoCAD SHX Text 6-113.7

AutoCAD SHX Text

EQUIP.

AutoCAD SHX Text

ROOM

AutoCAD SHX Text 6-113.5

AutoCAD SHX Text ALBERT JOSEPH COOPER III AR-0010460 STATE OF FLORIDA REGISTRATION NUMBER AA-C001315

AutoCAD SHX Text

AutoCAD SHX Text 09/18/2023

AutoCAD SHX Text

100% CONSTRUCTION DOCUMENTS

Consultant ● Seal/Signature

Sheet Title:

Project Number:

2022-538

Scale:38''

File Name

Drawn By:

Checked By

AR

CH

ITE

CT

UR

E

PL

AN

NI

NG

IN

TE

RI

OR

D

ES

IG

N

SP

AC

E

PL

AN

NI

NG

Issue Date:09/18/2023 Project Status:

100% CONSTRUCTION DOCUMENTS

PR

IN

TE

D

ON

Client Information

ADCARCHITECTURAL DESIGN COLLABORATIVE

Architect ● Seal/Signature

Issue

Project Documents for:

Date Issue Description

Project:

Check By

945 N. PENNSYLVANIA AVENUE

WINTER PARK, FLORIDA 32789

OFFICE: (407) 629-1188

FAX: (407) 388-1220

WWW. ADCINTERNATIONAL.NET

2022-538

PANEL SCHEDULES

E701

AutoCAD SHX Text ALBERT JOSEPH COOPER III AR-0010460 STATE OF FLORIDA REGISTRATION NUMBER AA-C001315

AutoCAD SHX Text

AutoCAD SHX Text 09/18/2023

AutoCAD SHX Text

100% CONSTRUCTION DOCUMENTS

* NOTE

THIS MATERIAL WAS EXTRACTED BY 3M FIRE PROTECTION PRODUCTS FROM THE 2002

EDITION OF THE UL FIRE RESISTANCE DIRECTORY

1. Wall Assembly - The 1 or 2 hr fire rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the manner described in the individual U300 or U400 Series Wall or Partition Designs in the UL Fire Resistance Directory and shall include the following construction features:

A. Studs - Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in.

lumber spaced 16 in. OC with nom 2 by 4 in. lumber end plates and cross braces. Steel studs to be min 3-5/8 in. wide by 1-3/8 in. deep channels spaced max 24 in. OC.

B. Gypsum Board* - Nom 5/8 in. thick, 4 ft. wide with square or tapered edges. The gypsum wallboard type, number of layers and sheet orientation shall be as specified in the individual Wall and Partition Design. Diam of circular through opening cut through gypsum wallboard on each side of wall assembly to be min 0 in. (point contact) to max 1 in. larger than outside diam of flexible metal conduit (Item 2) installed in through opening. Side edge of circular opening to be min 3 in.

from nearest stud in wall cavity.

C. Fasteners - When wood stud framing is employed, gypsum wallboard attached to studs with cement coated nails as specified in the individual Wall or Partition Design. When steel channel stud framing is employed, gypsum wallboard attached to studs with Type S self-drilling, self-tapping bugle-head steel screws as specified in the individual Wall or Partition Design.

2. Through Penetrating Product* - Flexible Metal Conduit - Nom 4 in. diam (or smaller) aluminum or steel Flexible Metal Conduit+. Max one flexible metal conduit to be installed near center of circular opening in gypsum wallboard. Flexible metal conduit to be rigidly supported on both sides of wall assembly.

AFC CABLE SYSTEMS INC

3. Fill,Void or Cavity Material* - Caulk - Caulk fill material forced into annular space around entire circumference of through penetrating product to completely fill opening in gypsum wallboard layers on each side of the wall assembly. A min 5/8 in.

thickness of caulk is required for the 1 hr F Rating. A min 1-1/4 in. thickness of caulk is required for the 2 hr F Rating.

MINNESOTA MINING & MFG CO - CP 25WB+

*Bearing the UL Classification Marking

F RATINGS-- 1 AND 2 HR (SEE ITEM 3)

T RATING-- 0 HR

L RATING AT AMBIENT--LESS THAN 1 CFM/sq ft L RATING AT 400° F--LESS THAN 1 CFM/sq ft

SYSTEM NO. W-L-1017

A

A

1C

1B

1A

SECTION A-A

SECTION A-A

1 44

A

A

1. Floor or Wall Assembly — Min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3) concrete. Wall may also be constructed of any UL Classified Concrete Blocks*. Max diam of opening ) is 27-1/4 in. (692 mm).

See Concrete Block (CAZT) category in the Fire Resistance Directory for names of manufacturers.

1A. Steel Sleeve — (Optional, Not Shown) - Nom 28 in. (711 mm) diam (or smaller) Schedule 10 (or heavier) steel sleeve cast or grouted into floor or wall assembly. As an alternate, nom 28 in. (711 mm) diam (or smaller) sleeve fabricated from nom 0.028 in. (0.71 mm) thick galv steel cast or grouted into floor or wall assembly flush with floor or wall surfaces.

2. Through-Penetrant — One metallic pipe, conduit or tubing to be installed either concentrically or eccentrically within the firestop system. An annular space of min 0 in. (point contact) to max 3-1/4 in. (83 mm) is required within the firestop system . When optional steel sleeve is used, min annular space shall be 1/2 in. (13 mm). Pipe, conduit or tubing to be rigidly supported on both sides of floor or wall assembly. The following types and sizes of metallic pipes, conduits or tubing may be used:

A. Steel Pipe — Nom 24 in. (610 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe. When Type FB-1000 NS or FB-1003 SL sealant (see Item 4) is used, pipe diam shall not exceed nom 8 in. (203 mm).

B. Conduit — Nom 4 in. (102 mm) diam (or smaller) steel electrical metallic tubing or nom 6 in. (152 mm) diam (or smaller) steel conduit.

C. Copper Tubing — Nom 6 in. (152 mm) diam (or smaller) Type L (or heavier) copper tubing. When Type FB-1000 NS or FB-1003 SL sealant (see Item 4) is used, tubing diam shall not exceed nom 4 in.

(102 mm).

D. Copper Pipe — Nom 6 in. (152 mm) diam (or smaller) Regular (or heavier) copper pipe. When Type FB-1000 NS or FB-1003 SL sealant (see Item 4) is used, pipe diam shall not exceed nom 4 in. (102 mm).

E. Iron Pipe — Nom 24 in. (610 mm) diam (or smaller) cast or ductile iron pipe. When Type FB-1000 NS or FB-1003 SL sealant (see Item 4) is used, pipe diam shall not exceed nom 8 in. (203 mm).

3. Packing Material — Min 3 in. (76 mm) thickness of min 4 pcf (64 kg/m3) mineral wool batt insulation firmly packed into opening as a permanent form. Packing material to be recessed from top surface of floor or from both surfaces of wall as required to accommodate the required thickness of fill material.

3A. Forming Material* — As an alternate to the packing material in Item 3, nom 4 in. (102 mm) wide strips of min 1/2 in (13 mm) thick compressible mat to be stacked to a thickness greater than the width of the annular space and compression-fitted, edge-first, to fill the annular space to a min 4 in. (102 mm) depth. Top of forming material to be recessed from top surface of floor or steel sleeve or from both surfaces of wall or steel sleeve in wall as necessary to accommodate the required thickness of caulk fill material.

3M COMPANY 3M FIRE PROTECTION PRODUCTS — Fire Barrier Packing Material

4. Fill, Void or Cavity Material* — Sealant — Min 1/2 in. (13 mm) thickness of fill material applied within annulus, flush with top surface of floor or both surfaces of wall assembly. At the point contact location between pipe and concrete, a min 1/2 in. (13 mm) diam bead of sealant shall be applied at the concrete/pipe interface on the top surface of floor and on both surfaces of wall assembly.

3M COMPANY 3M FIRE PROTECTION PRODUCTS — Types FB-2000, FB-2000+, FB-1000 NS, FB-1003 SL or

FB-3000 WT.

(Note - W Rating applies only when FB-1000 NS, FB-1003 SL or FB-3000 WT Sealant is used.)

*Bearing the UL Classification Mark

System No. C-AJ-1058 May 09, 2013

ANSI/UL1479 (ASTM E814)

F Rating — 3 Hr T Rating — 0 Hr

L RATING AT AMBIENT — LESS THAN 1 CFM/SQ FT

L RATING AT 400 F — LESS THAN 1 CFM/SQ FT

W RATING — CLASS 1 (SEE ITEM 4)

System No. C-AJ-1058 May 09, 2013

CAN/ULC S115

F Rating — 3 Hr

FT Rating — 0 Hr FH Rating — 3 Hr

FTH Rating — 0 Hr

L RATING AT AMBIENT — LESS THAN 1 CFM/SQ FT L

RATING AT 400 F — LESS THAN 1 CFM/SQ FT

BUNDLED VOICE/DATA PDS CABLING, RUN

FROM CABLE TRAY, THROUGH

PENETRATION

FIRE-RATED

PARTITION

4" EMT SLEEVE

CABLE TIE

SECTION THOUGH RATED WALL

UL LISTED FIRE-WALL PENETRATION ASSEMBLY, WIREMOLD

"FLAMESTOPPER FS-4" SERIES, STI "EZ PATH SYSTEM" OR

APPROVED SUBSTITUTE

ADJUSTING

SCREWS (2)

INTEGRAL INTUMESCENT

FIRESTOPPING MATERIAL

FRONT VIEW ISOMETRIC VIEW

4" EMT SLEEVE

Consultant ● Seal/Signature

Sheet Title:

Project Number:

2022-538

Scale:38''

File Name

Drawn By:

Checked By

AR

CH

ITE

CT

UR

E

PL

AN

NI

NG

IN

TE

RI

OR

D

ES

IG

N

SP

AC

E

PL

AN

NI

NG

Issue Date:09/18/2023 Project Status:

100% CONSTRUCTION DOCUMENTS

PR

IN

TE

D

ON

Client Information

ADCARCHITECTURAL DESIGN COLLABORATIVE

Architect ● Seal/Signature

Issue

Project Documents for:

Date Issue Description

Project:

Check By

945 N. PENNSYLVANIA AVENUE

WINTER PARK, FLORIDA 32789

OFFICE: (407) 629-1188

FAX: (407) 388-1220

WWW. ADCINTERNATIONAL.NET

2022-538

ELECTRICAL DETAILS

E801

AutoCAD SHX Text

MC CABLE THRU GYP BOARD PENETRATION DETAIL

AutoCAD SHX Text No Scale

AutoCAD SHX Text

AutoCAD SHX Text

EMT THRU CONCRETE PENETRATION DETAIL

AutoCAD SHX Text No Scale

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

DETAIL - UL LISTED FIRE WALL PENETRATION ASSEMBLY FOR VOICE/DATA PDS CABLE

AutoCAD SHX Text No Scale

AutoCAD SHX Text

PENETRATIONS THROUGH RATED WALLS

AutoCAD SHX Text ALBERT JOSEPH COOPER III AR-0010460 STATE OF FLORIDA REGISTRATION NUMBER AA-C001315

AutoCAD SHX Text

AutoCAD SHX Text 09/18/2023

AutoCAD SHX Text

100% CONSTRUCTION DOCUMENTS

M001 MECHANICAL SYMBOL SPECIFICATIONS
MD201 MECHANICAL DEMO FLOOR PLAN
M201 MECHANICAL FLOOR PLAN PROPOSED
M801 MECHANICAL DETAILS
E001 ELECTRICAL SYMBOL SPECIFICATIONS
ED201 LIGHTING DEMO PLAN
ED301 POWER DEMO PLAN
E101 EXHIBIT LEVEL 1
E201 LIGHTING PLAN RCP
E301 POWER PROPOSED PLAN
E701 PANEL SCHEDULES
E801 ELECTRICAL DETAILS

File details come from the government source that posted it. Updated .