Drawings_D0SWN00009.pdf
PDF 3 MB Posted
- Solicitation number
- 2120984
- Issued by
- Erie County, New York
About this file
This document is a set of architectural drawings and specifications for a chimney and roof replacement project for the New York State Office for People with Developmental Disabilities (OPWDD), located at 328 Buffalo Street in Gowanda, NY. The project involves comprehensive roof and chimney renovation, including complete removal of existing roofing materials, installation of a new 60-mil EPDM single-ply roof membrane, replacement of roof joists, fascia, soffit, gutters, and chimney reconstruction. The work is specifically focused on a two-story residential building with Type 5B construction and will be completed from the building's exterior without disturbing interior occupants.
The project specifications detail precise requirements for materials and installation, with specific manufacturers designated as basis of design, such as Carlisle Syntec for roofing membrane, GAF-Elk for asphalt shingles, and Huntsman Building Solutions for spray foam insulation. The roofing system will include a 20-year manufacturer's warranty, with specific performance requirements for materials like spray foam insulation, including thermal resistance, air leakage, and fire-response characteristics. The total project involves unit pricing for roof rafters, plywood sheathing, and chimney reconstruction, with the contractor required to provide all labor, materials, and equipment necessary to complete the work in compliance with New York State building codes and OPWDD regulations.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Project Manual - D0SWN00009.pdf | ||
| ADDENDUM 1- D0SWN00009.pdf | ||
| Q&A Memo - D0SWN00009.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BUILDING DATADRAWING INDEX
CONSTRUCTION TYPE: TYPE 5B
OCCUPANCY CLASSIFICATION: RESIDENTIAL GROUP R-3
NUMBER OF STORIES: TWO
SPRINKLER SYSTEM: NONE
CODE COMPLIANCE:
NYS 2020 RESIDENTIAL CODE
NFPA 101 LIFE SAFETY CODE
NFPA 211 STANADRD FOR CHI,MNEYS, FIREPLACES, VENTS AND SOLID FUEL BURNING APPLIANCES
CHAPTER 33 - EXISTING RESIDENTIAL BOARD & CARE OCCUPANCIES
ANSI - A117.1 (2009) ACCESSIBLE AND USEABLE BUILDING AND FACILITIES
NATIONAL ELECTRIC CODE
ALL GOVERNING LOCAL CODES
ZAXIS ARCHITECTURAL P.C. CERTIFIES TO THE BEST OF OUR KNOWLEDGE THAT THE DRAWINGS PROVIDED ARE COMPLETE AND IN COMPLIANCE WITH THE NYS UNIFORM BUILDING CODES, THE NYS
ENERGY CODES AND ALL RELEVANT OPWDD REGULATIONS AND REQUIREMENTS
ARCHITECTURAL
COVER SHEET CS-1
FLOOR PLANS A-101
ROOF AND CHIMNEY SECTIONS AND DETAILS A-401
SPECIFICATIONS SP-101
CHIMNEY & ROOF REPLACEMENT
328 BUFFALO STREET, GOWANDA, NY 14070
NYS OFFICE FOR PEOPLE WITH DISABILITIES
1200 EAST AND WEST ROAD
WEST SENECA, NY 14224
4245 UNION ROAD, SUITE 210
BUFFALO, NEW YORK 14225
P:716.923.0133 F:716.923.0136
SITE LOCATION MAP
UNIT PRICING
PROVIDE UNIT COST - INCLUDING FURNISHING ALL MATERIAL AND ALL LABOR INSTALLATION, INCLUDE THE COST OF REMOVAL OF THE EXISTING DETERIORATED MATERIAL FOR THE FOLLOWING ITEMS:
1. ROOF RAFTER (FIELD VERIFY AND MATCH EXISTING DEPTH):
A.) 2" x 6", 20' LENGTH ________ DOLLARS ($_____) PER UNIT.
B.) 2" x 8", 20' LENGTH ________ DOLLARS ($_____) PER UNIT.
C.) 2" x 10", 20' LENGTH ________DOLLARS ($_____) PER UNIT.
D.) 2" x 12", 20' LENGTH ________DOLLARS ($_____) PER UNIT.
2. 3 4" PLYWOOD CDX EXTERIOR GRADE T&G ROOF SHEATHING PER 4'x8' SHEET
3. BRICK CHIMNEY REMOVAL AND REPLACEMENT BEYOND THE SPECIFIC SCOPE OF WORK. PER THE
FOLLOWING UNIT:
A.) FOR EACH THREE (3) COURSES OR 8" IN HEIGHT FOR THE ENTIRE CHIMNEY PERIMETER
4. REMOVE AND REPLACE THE ENTIRE EXISTING HOT WATER TANK VENT PIPE AND THE EXISTING FURNACE VENT PIPE FROM WITHIN THE ENTIRE LENGTH OF THE CHIMNEY, UTILIZING MATCHING
MATERIALS AND RECONNECT TO ENSURE PROPER OPERATION OF THE EXISTING HOT WATER
TANK AND THE EXISTING FURNACE
PROJECT SITE
DRAWING No.
PROJECT No: 23-023
DATE: 11-30-23
R
EV
IS
IO
N S
D
AT
E N o.-
CS-1
-3
0-
ZA
XI
S
AR
C H
IT
EC
TU
R
AL
P
.C
TH
IS
D O
C U
M
EN
T, A
N D
T H
E
ID
EA
S
AN
D
D
ES
IG
N
S
IN
C O
R
PO
R
AT
ED
H
ER
EI
N , A
R E
TH
E
PR
O
PE
R
TY
O
F
ZA
XI
S
AR
C
H
IT
EC
TU
R
AL
P .C
U N
AU
TH
O R
IZ
ED
R
EP
R O
D U
C
TI
O N
, A
LT
ER
AT
IO
N
O R
A D
D
IT
IO
N
T O
A N
Y D
R
AW
IN
G
D
ES
IG
N , S
PE
C
IF
IC
AT
IO
N , P
LA
N
O R
R
EP
O R
T
IN
W H
O
LE
O R
IN
P
AR
T
W
IT
H O
U T
TH
E
EX
PR
ES
S
W R
IT
TE
N A
U
TH
O R
IZ
AT
IO
N
O F
ZA
XI
S
AR
C H
IT
EC
TU
R
AL
P
.C . I
S
PR
O H
IB
IT
ED
B
Y
SE
C
TI
O N
9, P
R O
VI
SI
O N
O
F
TH
E N
EW
Y
O R
K
ST
AT
E
ED
U
C
AT
IO
N
L
AW
C H
IM
N
EY
R O
O F
R
EP
LA
C
EM
EN
T N
YS
O
FF
IC
E
FO
R P
EO
PL
E W
IT
H
D
IS
AB
IL
IT
IE
S
B
U
FF
AL
O
S
TR
EE
T, G O
W
AN
D A, N Y
1- 3-
R
EI
SS
U
ED
P
ER
O W
N
ER
'S C
O M
M
EN
TS
IS
SU
ED
F
O R
R
EV
IE
W
1-
-2
R
EI
SS
U
ED
P
ER
O W
N
ER
'S C
O M
M
EN
TS
stroudjj Accepted For Construction
+/- 1 TO 1 1/2:12
ROOF SLOPE V.I.F.
EXISTING HIGH (2)
STORY HIP ROOF
(NIC)
EXISTING SINGLE
STORY PORCH ROOF
(NIC)
EXISTING SINGLE
STORY PORCH ROOF
RIDGE
EX
IS
T.
R
ID
G
E
R
ID
G E
+/- 11'-4"
(FOLLOWING SLOPE
RIDGE TO FASCIA)
EXISTING (2) STORY
GABLE ROOF
EXISTING (1) STORY
GABLE ROOF
(NIC)
EXIST.
LOW
SHED
ROOF
NIC
EXIST. LOW
SHED ROOF
(NIC)
- 1 2'
-0
- 2
'-2 1 2"
- 7
'-6
1'-41 2"
FACE OF EXIST.
BLDG. WALL BELOW
(DASHED)
A-401
ROOF PLAN
1/4" = 1'-0''
AREA OF NEW
WORK
EXISTING
RIDGE VENT
EQ
EQ
EQ
LINE OF BUILDING
WALLS BELOW
EXISTING GUTTER - TYP
EXIST. LOW
FLAT ROOF
(NIC)
+/- 6:12 ROOF
SLOPE V.I.F.
+/- 6:12 ROOF
SLOPE V.I.F.
EXISTING (1) STORY
SHED ROOF
EXTENSION
(NIC)
EXISTING SINGLE
STORY PORCH ROOF
(NIC)
D1
D4
D3 4
GABLE END
2D2
2D2
2D2
EXISTING GUTTER
EXISTING GUTTER
'-8
1 2"
KEYED CONSTRUCTION NOTES
PROVIDE ROOF MEMBRANE SYSTEM AS FOLLOWS:
A. FULLY ADHERED SINGLE PLY ROOF MEMBRANE SYSTEM:
60 MIL NON-REINFORCED SINGLE PLY EPDM
MANF: CARLISLE SYNTEC (BASIS OF DESIGN)
WARRANTY 20 YR.
COLOR: BLACK
B. ROOF DECK: 3 4" CDX EXTERIOR GRADE T & G PLYWOOD
C. PROVIDE MANF. REQUIRED FLASHING FOR CHIMNEY AND
ADJACENT BRICK WALL AS DETAILED.
D. PROVIDE MIN. R-49 SPRAY FOAM INSULATION BETWEEN THE
EXISTING ROOF RAFTERS
PROVIDE FASCIA
A. 2X12 (VIF MATCH EXIST.) CONTINUOUS ALUMINUM CLAD WOOD
FASCIA BOARD
B. PROVIDE WOOD BLOCKING FOR FLASHING AND SOFFITS
PROVIDE 2X WOOD FRAMED CRICKET WITH PLYWOOD DECK FOR
PROPER ROOF DRAINAGE AROUND THE CHIMNEY
PROVIDE WEATHER TIGHT TRANSITION OF THE SINGLE PLY ROOF
MEMBRANE AND ASPHALT SHINGLE ROOF SYSTEM AT THE RIDGE -
REFER TO DETAILS:
A. ASPHALT SHINGLES BASIS OF DESIGN:
MANF: GAF-ELK MATERIALS CORPORATION
MODEL: TIMBERLINE HD
COLOR: SHALL MATCH EXISTING
B. ICE AND WEATHER SHIELD (LEAK BARRIER) BASIS OF DESIGN
MANF: GAF-ELK MATERIALS CORPORATION
THICKNESS: 40 MIL MIN.
(THE ICE AND WEATHER SHIELD SHALL BE PROVIDED BY THE
SAME MANF. AS THE ASPHALT SHINGLES)
PROVIDE (2) 12" GRAVITY VENTILATORS REFER TO DETAIL 2/A-401 FOR
BASIS OF DEIGN.
PROVIDE 6" ALUMINUM GUTTER WITH "K" STYLE GUTTER BRACKET AND
GUTTER DEBRIS GUARD.
- SLOPE GUTTERS A MINIMUM OF 14" PER FOOT
- PROVIDE WIRE BALL DOWNSPOUT STRAINER AND VALLEY
BAFFLES
- PROVIDE CONTINUOUS SINGLE LENGTHS OF GUTTERS, NO JOINTS
MID LENGTH
- PROVIDE SHOP FABRICATED INTERIOR AND EXTERIOR CORNERS
- COLOR: SHALL MATCH EXISTING
A. GUTTER DEBRIS GUARD:
- MANF: GUTTER GUARD
- MODEL: GUTTER GLOVE PRO
- DESCRIPTION: EXTRUDED ALUMINUM FRAME WITH FINE WOVEN
STAINLESS STEEL MESH
PROVIDE 3"X4" RECTANGULAR ROOF DRAIN LEADERS (RDL)
(DOWNSPOUTS)
- PROVIDE STANDARD HANGERS AND SECURE
- RECONNECT RDL TO EXISTING GUTTER WITH DOWN TURNED
ELBOW
PROVIDE ALUMINUM SOFFIT PANELS AT ALL ROOF OVERHANGS AND
GABLE END RAKES. REFER TO DETAILS:
A. MANF: ATAS INTERNATIONAL INC.
C. WIND LOK OVERHANG SOFFITS MPV 120 AND WIND LOK GABLE END
RAKES MPS 120 (SMOOTH NON-VENTED)
D. FIELD VERIFY WIDTH X 3 8" HGT. (LENGTH AS REQ.)
E. THICKNESS: 032 ALUMINUM
F. COLOR: WHITE - MATCH EXISTING
CHIMNEY: REPOINT THE EXISTING REMAINING PORTION OF THE
CHIMNEY AND RECONSTRUCT THE REMOVED PORTION:
A. REPOINT: REFER TO DETAIL 1/A-401
B. RECONSTRUCTION:
- THE PORTION OF THE REMOVED CHIMNEY SHALL BE
RECONSTRUCTED TO MATCH THE EXISTING CHIMNEY'S SIZE
LENGTH, WIDTH AND HEIGHT - REFER TO THE MINIMUM CODE
REQUIRED HEIGHT AND EXTEND ACCORDING.
- REFER TO DETAILS ON DWG. A-401
IN GENERAL:
- THE EXISTING BRICK CHIMNEY IS TO REMAIN THREE COURSE OF
BRICK BELOW THE EXISTING PORCH ROOF PLYWOOD ROOF DECK.
- THE EXISTING GRAVITY VENTED HOT WATER TANKS & FURNACE IN
THE BASEMENT ARE TO REMAIN. PROVIDE TEMPORARY SUPPORT
P2: EXIST. SINGLE PLY ROOF P3: VIEW FROM NORTH P4: EXIST. CHIMNEY - ROOF P5: EXIST ROOF RIDGE P6: EXIST. ROOF CONNECTION P7: FASCIA AND SOFFITP1: VIEW FROM PORCH
PROJECT REFERENCE PHOTOS
FIELD VERIFY ALL CONDITONS
GENERAL NOTES
A. CONTRACTOR SHALL PROVIDE TEMPORARY SHORING/BRACING
DURING, DEMOLITION AND SELECTIVE REMOVAL PROCESS, TO
ENSURE THAT EXISTING BUILDING COMPONENTS DO NOT
DEFLECT, MOVE OR OTHERWISE BECOME DAMAGED DURING THE
REMOVAL PROCESS OR WHILE NEW WORK IS BEING PERFORMED
B. THE CONTRACTOR SHALL REMOVE ALL EXISTING ITEMS
ATTACHED TO THE EXISTING ROOF/FACIA/SOFFIT/JOISTS SUCH AS
NAILS, SCREWS, ANCHORS, HOOKS ETC. AND PATCH THE
ASSOCIATE HOLES, ETC FOR THE INSTALLATION OF NEW WORK.
C. DEMOLITION WORK SHALL INCLUDE ALL WORK NECESSARY TO
COMPLETE INSTALLATION OF NEW WORK/MATERIALS. WHERE
EXISTING CONDITIONS INTERFERES WITH NEW WORK - WHETHER
OR NOT SPECIFICALLY INDICATED TO BE REMOVED, THE
CONTRACTOR SHALL PERFORM COORDINATION AND REMOVE
THE MATERIAL TO THE EXTENT THAT THE NEW WORK SHALL BE
PROPERLY INSTALLED
D. ALL DAMAGED MATERIALS OR REMOVALS PERFORMED BEYOND
THAT WHICH IS REQUIRED FOR THE INSTALLATION OF NEW WORK
OR WHERE EXISTING MATERIALS ARE INTENDED TO REMAIN, THE
CONTRACTOR SHALL REPLACE THE DAMAGED MATERIALS WITH
NEW MATERIALS IN A "LIKE NEW" CONDITION
E. THE CONTRACTOR SHALL PROVIDE TARPS ON THE GROUND TO
CAPTURE SMALL DEBRIS INCLUDING FASTENERS THROUGHOUT
ALL PHASES OF WORK
F. CONTRACTOR SHALL PERFORM A FINAL GROUND CLEAN-UP AND
REMOVE ALL DEBRIS. INCLUDING ALL FASTENERS FROM THE
SURROUNDING WORK AREA
G. THE CONTRACTOR SHALL PROVIDE TARPS AND SECURE
WEATHER TIGHT TO TEMPORARILY PROTECT THE BUILDING FROM
ADVERSE WEATHER DURING ALL PHASES OF THE WORK
H. THE CONTRACTOR SHALL REMOVE ALL DEMOLITION
DEBRIS/MATERIAL DAILY
I. THE WORK OF THE CONTRACTOR SHALL INCLUDE LABOR,
MATERIALS, TOOLS, EQUIPMENT, SERVICES, ETC. NECESSARY OR
INCIDENTAL TO HIS/HER PORTION OF THE WORK SHOWN ON THE
DRAWINGS AND HEREIN SPECIFIED. SHOP DRAWINGS AND/OR
SAMPLES SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW
FOR ALL WORK OR MATERIALS REQUIRING FABRICATION,
QUALITY APPROVAL, OR COLOR SELECTION.
J. THE CONTRACTOR SHALL ORDER AND HAVE ALL MATERIALS
AVAILABLE BEFORE STARTING WORK, TO INSURE THAT ONCE THE
WORK IS STARTED, IT SHALL PROCEED CONTINUOUSLY UNTIL
COMPLETE.
K. THE CONTRACTOR SHALL ASCERTAIN THE LOCATION OF ALL
UTILITY LINES AND TAKE PROPER PRECAUTION NOT TO DISTURB
ANY EXISTING UTILITIES UNLESS AUTHORIZED. THE
CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ANY DAMAGE
TO UTILITY LINES DURING THE PROCESS OF WORK UNDER THE
CONTRACT.
L. THE CONTRACTOR SHALL CAREFULLY EXAMINE THE DRAWINGS
AND VERIFY THE PROVISIONS ARE ADEQUATE FOR THE PROPER
INSTALLATION OF EACH ITEM. SHOULD THERE BE ANY CONDITION
THAT WILL PREVENT A THOROUGHLY SATISFACTORY
INSTALLATION, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT
AND OWNER, PRIOR TO BEGINNING WORK. FAILURE OF
NOTIFICATION WILL CONSTITUTE ACCEPTANCE OF THE
CONDITIONS, AND THE CONTRACTOR SHALL MAKE ANY
NECESSARY CHANGES TO PROPERLY ACCOMMODATE EACH ITEM
AT HIS/HER COST.
M. ALL WORK MUST COMPLY WITH NEW YORK STATE BUILDING
CONSTRUCTION CODE, AISC CODE, ACI BUILDING CODE, AWI
CODE, ASTM STANDARDS AND ANY OTHER APPLICABLE CODE,
RULES AND REGULATION BY AGENCIES HAVING JURISDICTION.
WHERE CODES OVERLAP, COMPLY WITH THE MORE STRINGENT
REQUIREMENTS.
N. THE CONTRACTOR SHALL MAINTAIN INSURANCE WHICH WILL
PROTECT HIM/HER FROM LIABILITY UNDER WORKMEN'S
COMPENSATION ACTS AND OTHER EMPLOYEE BENEFITS ACTS IN
ACCORDANCE WITH THE LAWS OF NEW YORK STATE, AND FROM
LIABILITY FOR DAMAGES BECAUSE OF BODILY INJURY, INCLUDING
DEATH AND PROPERTY DAMAGE.
O. CONTRACTOR IS TO REVIEW DRAWINGS AND EXISTING SITE
CONDITIONS AND DIMENSIONS FOR SCOPE OF THE WORK
INVOLVED. CONTRACTOR IS TO INCLUDE, IN HIS/HER PROPOSAL,
ALL ITEMS, MATERIALS, ETC. TO ACHIEVE THE DESIGN CONCEPT
AS SHOWN ON THE DRAWINGS.
P. CONTRACTOR IS TO INCLUDE IN HIS/HER PROPOSAL ALL
ADDITIONAL MATERIALS AND LABOR AS REQUIRED TO WORK
AROUND EXISTING CONDITIONS.
Q. CONTRACTOR IS RESPONSIBLE FOR ALL MEANS, METHODS,
LABOR PROCEDURES AND SAFETY PRECAUTIONS FOR
COMPLETING WORK.
R. ALL WORKMANSHIP MUST BE IN THE BEST PRACTICE OF THE
TRADE AS DETERMINED BY THE ARCHITECT OR OWNER. ANY
WORK NOT MEETING THESE STANDARDS WILL BE REJECTED.
S. WHERE A SPECIFIC MANUFACTURER'S PRODUCT IS CALLED OUT,
ALL MATERIALS AND WORK MUST COMPLY WITH THE
MANUFACTURER'S STRICT RECOMMENDATIONS FOR
INSTALLATION AND/OR COORDINATION. IT IS THE CONTRACTOR'S
RESPONSIBILITY TO OBTAIN INSTRUCTIONS AND TO FOLLOW
THEM.
T. CONTRACTOR TO LEAVE THE RESIDENCE FREE FROM DEBRIS &
BROOM CLEAN AT THE END OF EACH WORK DAY.
THE BUILDING WILL BE OCCUPIED DURING CONSTRUCTION:
THE CONTRACTOR IS REQUIRED TO PERFORM THE FOLLOWING:
1. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN SAFE MEANS OF EGRESS
FROM ALL EXISTING BUILDING EXITS DURING ALL PHASES OF WORK,
INCLUDING PROVIDING TEMPORARY PROTECTIVE BARRIERS TO THE OWNER'S
DESIGNATED AREAS.
2. PROVIDE TEMPORARY BARRIERS TO SEPARATE ALL WORK AREAS, INCLUDING
STAGING AND STORAGE OF MATERIALS AND EQUIPMENT FROM THE BUILDING
OCCUPANTS AND GENERAL PUBLIC.
3. PROVIDE SIGNAGE CLEARLY IDENTIFYING WORK AND DANGER AREAS. ALSO,
WHEN WORK IS BEING PERFORMED NEAR OR ABOVE AN EXIT DOOR, PROVIDE
SIGNAGE TO OWNER - TO BE MOUNTED ON INTERIOR DOORS THAT STATES:
· "EMERGENCY EXIT ONLY"
4. THE CONTRACTOR SHALL PROVIDE OVERHEAD FALL PROTECTION AND
PROVIDE AND ADDRESS ALL SAFETY CONCERNS REQUESTED BY THE OWNER.
THE CONTRACTOR SHALL PERFORM A POST DEMOLITION INSPECTION WITH THE
OWNER AND ARCHITECT AND PREPARE A WRITTEN REPORT ON THE EXPOSED
SURFACES OF THE ATTIC AND OF THE EXISTING MECHANICAL FLUES WITHIN THE
EXISTING CHIMNEY. THE INSPECTION SHALL INCLUDE THE CONDITION OF AND
RECOMMENDATIONS FOR REPLACEMENT OF:
1. THE ROOF: WOOD ROOF JOIST, GYPSUM BOARD (CEILING) FASTENED TO THE
INSIDE OF THE ROOF JOISTS, REMAINING BLOCKING, PLYWOOD SHEATHING, WOOD
FASCIA BOARDS AND WOOD SOFFITS FRAMING WHERE THE MATERIALS ARE
INTENDED TO REMAIN AND BE REUSED AS BASE MATERIALS FOR NEW WORK.
2. THE CHIMNEY: THE EXISTING HOT WATER TANK AND THE FURNACE FLUE AND
CONNECTION TO THE CHIMNEY, EXISTING CLAY TILE FLUE LINER, EXISTING BRICK
SCHEDULED TO REMAIN.
THE CONTRACTOR SHALL INCLUDE IN THEIR BASE BID, THE LABOR AND MATERIAL COST
TO; REMOVE AND INSTALL THE FOLLOWING ITEMS. THE NEW MATERIALS SHALL MATCH
THE EXISTING SIZE AND MATERIALS VIF:
A. (4) FOUR - ROOF JOISTS 20' LENGTHS PER UNIT PRICING
UPON COMPLETION OF THE PROJECT ALL UNUSED MATERIAL AND LABOR SHALL BE
CREDITED BACK TO THE OWNER BASED ON UNIT MATERIAL RATES
POST DEMOLITION INSPECTION AND EVALUATION:
A
B
C
A
CHIMNEY CODE ANALYSIS AND
MINIMUM WORK REQUIREMENT
PER R1003.9 OF THE NYS RESIDENTIAL
CODE;
· THE BRICK CHIMNEY SHALL EXTEND ON
THE SHORTEST SIDE A MIN OF 3 FT.
ABOVE THE HIGHEST POINT WHERE THE
CHIMNEY PASSES THROUGH THE ROOF
AND
· MUST EXTEND A MIN. OF 2 FT. HIGHER
THAN ANY PORTION OF THE BUILDING
WITHIN 10 FT.
REMOVE ALL EXISTING ROOFING MATERIALS ENTIRELY, INCLUDING BUT
NOT LIMITED TO: ASPHALT SHINGLE, ROOF MEMBRANE MATERIALS, ALL
ROOF UNDERLAYMENT; ALL ROOF PATCHING MATERIAL SUCH AS ROOF
TAR, ALL FLASHINGS, INSULATION (SEALANTS, METAL DRIP EDGES, RIDGE
VENTS, PLYWOOD SHEATHING, ETC. ALL FASTENERS SHALL BE
REMOVED. EXPOSE THE EXISTING ROOF JOISTS & INTERIOR GYPSUM
WALL BOARD. BOTH ARE INTENDED TO REMAIN REFER TO POST
DEMOLITION INSPECTION REQ.
REMOVE ENTIRELY ALL EXISTING WOOD FASCIA BOARDS, ASSOCIATED
BLOCKING, ALUMINUM (METAL) CLADDING, DRIP EDGE AND SOFFIT
PANELS FROM THE PERIMETER FASCIA BOARDS AND GABLE END
BOARDS: INCLUDING BUT NOT LIMITED TO ALL FASTENERS AND
SEALANTS EXPOSING THE WOOD ROOF JOISTS.
REMOVE A PORTION OF THE EXISTING ASPHALT SHINGLES ROOF
SYSTEM, REFER TO NEW WORK - EXPOSING THE PLYWOOD ROOF DECK
FROM 24" ± FROM THE ROOF RIDGE - VERIFY THE TOTAL AMOUNT OF
REMOVAL AND REPLACEMENT WITH EACH ROOF MANF. WRITTEN
REQUIREMENTS.
EXISTING CHIMNEY (REFER TO NEW WORK) SHALL BE REMOVED
ENTIRELY FROM THE EXISTING PORCH ROOF DECK TO THE BRICK CAP,
INCLUDING THE ALL FLASHINGS AT THE ROOF CONNECTIONS. THE
EXISTING MECHANICAL FLUES ARE INTENDED TO REMAIN - REFER TO
POST DEMOLITION INSPECTION REQUIREMENTS. PROVIDE TEMPORARY
SUPPORTS FOR THE FLUES AND TEMPORARY WEATHER PROTECTION TO
ALL AFFECTED AREAS
KEYED DEMOLITION NOTES
D1
D2
D3
D4
D0
DESIGN INTENT CLARIFICATION:
IT IS THE OWNER'S INTENTION TO COMPLETE ALL WORK
FROM THE BUILDING EXTERIOR AND NOT TO DISTURB
THE INTERIOR OR BUILDING OCCUPANTS. SHOULD ANY
CONDITIONS EXIST TO PROHIBIT THE COMPLETION OF
THE WORK FROM THE EXTERIOR - NOTIFY OWNER &
ARCHITECT PRIOR TO PROCEEDING.
ROOF PLAN
A-101
4245 UNION ROAD, SUITE 210
BUFFALO, NEW YORK 14225
P: 716.923.0133 F: 716.923.0136
No. REVISIONS DATE
DRAWING TITLE:
DRAWING No.
architectural, p.c.
architecture planning consulting
- 11-30-23
DATE: 11-30-23
SCALE: AS SHOWN
DRAWN BY: DHH
CHECKED BY:
PROJECT No: 23-023
ISSUED FOR 100% REVIEW
NYS OFFICE FOR PEOPLE
WITH DISABILITIES
1200 EAST AND WEST ROAD
WEST SENECA, NY 14224
CHIMNEY & ROOF
REPLACEMENT
LOCATED AT:
328 BUFFALO STREET
GOWANDA, NY 14070
REISSUED PER OWNER'S COMMENTS 1-3-24-
REISSUED PER OWNER'S COMMENTS 1-30-24-
AutoCAD SHX Text
SCALE :
AutoCAD SHX Text
ZAXIS ARCHITECTURAL P.C.
AutoCAD SHX Text THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, ARE THE PROPERTY OF ZAXIS ARCHITECTURAL P.C. UNAUTHORIZED REPRODUCTION, ALTERATION OR ADDITION TO ANY DRAWING, DESIGN, SPECIFICATION, PLAN OR REPORT IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN AUTHORIZATION OF ZAXIS ARCHITECTURAL P.C. IS PROHIBITED BY SECTION 7209, PROVISION 2 OF THE NEW YORK STATE EDUCATION LAW.
+ 0'-0"
FINISH FLOOR / TOP OF CONC. PATIO FLOOR
A-401
KEYED SECTION THRU ROOF AND CHIMNEY ELEVATION
1/4" = 1'-0'' 1
A-401
EXISTING METAL SOFFIT
PANELS SHALL BE
TEMPORARILY REMOVED,
SALVAGES AND
REINSTALLED TO
PERFORM BRICK
INVESTIGATION,
REPOINTING AND BRICK
CLEANING WORK.
REPLACE THE METAL "J"
CHANNEL PERIMETER
SUPPORTS WHERE
DAMAGED DURING
REMOVAL
EXISTING WOOD BOARD TRIM SHALL BE
TEMPORARILY REMOVED, SALVAGES AND
REINSTALLED TO PERFORM BRICK
INVESTIGATION, REPOINTING AND BRICK
CLEANING WORK. PAINT REPLACED BOARDS
AFTER REINSTALLING
CLEAN AND REPOINT ALL REMAINING
EXISTING CHIMNEY BRICK, INCLUDING WITHIN
THE PATIO ROOF
EXISTING BRICK NOT ASSOCIATED WITH
THE CHIMNEY IS NOT IN CONTRACT (NIC)
LINE OF ROOF BEYOND
A-401
A-401
LINE OF ROOF BEYOND
EXISTING
PATIO ROOF
EXISTING DOOR
BEYOND
BRICK CHIMNEY
A-401
A-401
A-401
A-401
EXISTING ELECTRICAL RECEPTACLE AND
CONDUIT MOUNTED TO THE CHIMNEY SHALL
BE TEMPORARILY REMOVED, SUPPORTED
AND REINSTALLED
'-0
8"
M
IN
. 2
MIN. 10'
M
IN
. 3
7A A-401
AT LEAST 4"
USE ONE PIECE
METAL
NON-CORRODING
STEP FLASHING
FOR EACH
COURSE. SEAL
OVERLYING
SHINGLES TO
STEP FLASHING
WITH ASPHALT
PLASTIC CEMENT.
EXTEND
NON-CORRODING
METAL COUNTER
FLASHING OVER
BASE FLASHING.
WALL BEYOND
ASPHALT
SHINGLE
ROOF
SYSTEM
(PORCH)
CHIMNEY STEP FLASHING AT ASPHALT SHINGLE ROOF 8 CHIMNEY STEP FLASHING AT EPDM ROOF 7
EPDM FLASHING FULLY
ADHERED TO BRICK MIN 8"
VERT. ABOVE ROOF SURFACE
- INCLUDING BACKSIDE OF
CRICKET REFER TO DETAIL
7A/A-401
CRICKET BEYOND EPDM
MEMBRANE
ROOF
SOFFIT:
GUTTER AND
FASCIA NOT
SHOWN FOR
CLARITY
TERMINATION BAR
EPDM
MEMBRANE
ROOF
EXTEND PAST
GUTTER
(NOT SHOWN)
PRE-FINISHED NON-VENTED
ALUMINUM SOFFIT PANELS
EXISTING SIDING
PROVIDE PRE-FINISHED
ALUMINUM ROOF EDGE
FASCIA AND GUTTER
SYSTEM, REFER TO
DETAIL 5/A-401
PROVIDE BRICK CHIMNEY
BEYOND
METAL STEP FLASHING
REFER TO CHIMNEY DETAILS
CRICKET WITH 60 MIL EPDM
ROOFING SYSTEM
PROVIDE BRICK CHIMNEY
BEYOND
EXISTING WOOD FRAMING
ROOF RAFTERS AND
EXISTING BRICK AND WOOD
STUD WALL
EXISTING GYPSUM WALL BOARD
CEILING TO REMAIN
EPDM TRANSITION WITH TERMINATION
BAR REFER TO DETAIL 7A/A-401
PROVIDE
INSULATION
BAFFLE
PROVIDE SPRAY FOAM INSULATION
CLOSED CELL REFER TO KEYED
NOTES#1.D FOR MIN. R-VALUE
6A A-401
8" M
IN
PROVIDE BRICK CHIMNEY
REFER TO TYP. NOTES
BUILDING INTERIOR
8"
REMOVE AND RECONSTRUCT
BRICK CHIMNEY STARTING AT (3)
BRICK COURSES BELOW THE
EXISTING PATIO ROOF DECK
REFER TO INVESTIGATION
REQUIREMENTS
EXISTING TILE FLUE
TO REMAIN
INVESTIGATION
REQUIREMENTS
EXISTING PATIO ROOF
FRAMING AND ASPHALT ROOF
SHINGLE SYSTEM TO REMAIN
PROTECT FORM DAMAGE
DURING ALL PHASES OF
WORK
REMOVE AND REPLACE TWO
COURSES OF SHINGLES AROUND
THE CHIMNEY. MATCH THE
EXISTING COLOR, STYLE AND SIZE.
PROVIDE ICE AND WEATHER SHIELD
UNDERLAYMENT IN DISTURBED
AREAS
METAL STEP FLASHING
REFER TO CHIMNEY DETAILS
CHIMNEY CAP DETAIL 9
CHIMNEY - ROOF ELEVATION 6
NOTE:
REFER TO DETAIL 5/A-401 FOR SOFFIT, FASCIA, GUTTER,
ETC. NOTATIONS
CHIMNEY - PORCH ROOF DETAIL 3
SOFFIT/FASCIA/GUTTER DETAIL 5
PROVIDE 6" PRE-FINISHED
ALUMINUM GUTTER, UNDER
DRIP EDGE
PROVIDE EXTERIOR GRADE CDX
PLYWOOD T & G SHEATHING
PROVIDE FULLY ADHERED 60 MIL
EPDM SINGLE PLY MEMBRANE
PROVIDE GUTTER DEBRIS
GUARD
PRE-FINISHED ALUMINUM
DRIP EDGE, OVER
GUTTER AND FASCIA
PROVIDE PRE-FINISHED ALUMINUM
WRAPPED 2X12 (VIF) CONT. WOOD
FASCIA BOARD WITH DRIP
PROVIDE PRE-FINISHED ALUMINUM
SOFFIT PANEL NON-VENTED
PROVIDE WOOD BLOCKING TYP.
PROVIDE ROOF DRAIN LEADER
REFER TO PLAN
PROVIDE PRE-FINISHED
ALUMINUM ROOF EDGE FASCIA
WITH DRIP - AS PER MANF.
WRITTEN INSTRUCTIONS FOR
WARRANTY SYSTEM
EXISTING WOOD FRAMING
ROOF & (CLG) RAFTERS
PROVIDE INSULATION BAFFLE
PROVIDE SPRAY FOAM
INSULATION CLOSED CELL
REFER TO KEYED NOTES#1.D
FOR MIN. R-VALUE
EXISTING BRICK AND
WOOD FRAMED WALL
EXISTING SIDING - REPAIR
TRIM JUNCTURE WITH
SOFFIT FOR LIKE NEW
CONDITION
EXISTING GYPSUM WALL
BOARD CEILING TO REMAIN
EPDM FORM FLASH OVER DRIP
6A A-401
PROVIDE PRE-FINISHED
NON-VENTED ALUMINUM
SOFFIT PANELS
EXISTING SIDING
GABLE END RAKE SECTION 4
PROVIDE PRE-FINISHED
ALUMINUM ROOF EDGE
FASCIA WITH DRIP - AS
PER MANF. WRITTEN
INSTRUCTIONS FOR
WARRANTY SYSTEM
PRE-FINISHED ALUMINUM
WRAPPED WOOD FASCIA
W/ DRIP
12" VIF
PROVIDE WOOD BLOCKING
PROVIDE EXTERIOR GRADE CDX
PLYWOOD T & G SHEATHING
PROVIDE FULLY ADHERED 60 MIL EPDM
SINGLE PLY MEMBRANE
PROVIDE
INSULATION BAFFLE
FASTEN TO FACE
OF WOOD JOIST
PROVIDE SPRAY FOAM
INSULATION CLOSED CELL
REFER TO KEYED NOTES#1.D
FOR MIN. R-VALUE
6A A-401
RIDGE AND VENT DETAIL 2
PROVIDE EXTERIOR
GRADE CDX PLYWOOD
T & G SHEATHING
PROVIDE ARCHITECTURAL SHINGLE
ROOFING TO MATCH EXISTING
EXISTING WOOD FRAMING ROOF RAFTERS
PROVIDE PREFINISHED ALUMINUM
OVER-LAYMENT STRIP MIN 0.40 MATERIAL
THICKNESS SECURE THE OVER-LAYMENT
STRIP AS REQUIRED BY THE EPDM MANF.
WRITTEN INSTRUCTIONS EXISTING SHINGLE SIDE OF THE ROOF:
· REMOVE EXISTING CONTINUOUS RIDGE VENT
· REMOVE AND REPLACE A MIN. OF 4 COURSES OF SHINGLES. THE EXISTING UNDERLAYMENT
SHALL ONLY BE REMOVED WHERE THE PLYWOOD IS TO BE REMOVED
· SAWCUT AND REMOVE 12" OF PLYWOOD SHEATHING FROM THE RIDGE BOARD.
· PROVIDE SPRAY FOAM INSULATION FROM THE RIDGE BOARD TO 16" BEYOND THE RIDGE
BOARD TO THE UNDERSIDE OF THE EXISTING (REMAINING) PLYWOOD SHEATHING
· INFILL THE REMOVED SHEATHING WITH NEW PLYWOOD - MATCH THE DEPTH OF THE EXISTING
SHEATHING (VIF)
· PROVIDE GRAVITY VENTS
· PROVIDE ASPHALT ROOF SHINGLE SYSTEM WITH CONTINUOUS ICE AND WEATHERSHIELD
OVERLAP THE NEW UNDERLAYMENT OVER THE EXISTING UNDERLAYMENT A MIN. OF ONE
FULL NEW SHINGLE
· DO NOT OVERLAP AND ALLOW THE EPDM MEMBRANE AND SHINGLE TO TOUCH. MAINTAIN A
SEPARATION OF MATERIALS WITH THE ALUMINUM CAP FLASHING PER MANF. REQ.
PROVIDE FULLY ADHERED
60 MIL EPDM SINGLE PLY
ROOF MEMBRANE
PLASTIC VENT (BASIS OF DESIGN):
MANF: GAF-ELK MATERIALS CORPORATION
MODEL 1R-65
DESCRIPTION: SIZE TO FIT EXISTING OPENING
ONE PIECE MATERIAL MIN 65 SQ INCHES
UNDER SHINGLES
ON HIGH SIDE
PROVIDE PLASTIC AIR
VENT
OVER SHINGLES ON
LOW SIDE AND
PROPERLY FLASH
EXISTING WOOD RIDGE BOARD (VIF)
SAW-CUT OPENING IN
PLYWOOD DECK - DO NOT
DISTURB THE EXISTING
ROOF JOIST
PROVIDE INSULATION BAFFLE
7"±
PROVIDE SPRAY FOAM INSULATION
CLOSED CELL REFER TO KEYED
NOTES#1.D FOR MIN. R-VALUE
PROVIDE PREFINISHED ALUMINUM RIDGE
CAP MIN 0.40 MATERIAL THICKNESS SECURE
THE RIDGE CAP AS REQUIRED BY THE EPDM
MANF. WRITTEN INSTRUCTIONS
PROVIDE
INSULATION BAFFLE
PROVIDE FULLY ADHERED
EPDM FORM FLASH AND
SEALANT
INSULATION BAFFLE (BASIS OF DESIGN):
MANF: SMART BAFFLE
SIZE: VIF JOIST SPACE x 36" LONG LOCATE BOTTOM OF BAFFLE TO PROVIDE SPECIFIED R-49 INSULATION (7"+/- PER BASIS OF DESIGN
MANF. R-VALUE)
OVERLAP PANELS PER MANF. REQUIREMENTS
FASTEN TO JOIST AND BEND TO PROVIDE TERMINATIONS (i.e. SOFFIT) PER MANF. WRITTEN REQUIREMENTS OR IF NOT STATED PROVIDE BASED ON A 36" LONG PANEL, A MIN. OF ONE NAIL ON EACH
SIDE AT EACH END AND CENTER OF THE PANEL
3" MIN
4" MIN. COMPRESSION MATERIAL TYP. BUTYL
OR URETHANE - NO SILICONE
EXISTING TILE FLUE TO REMAIN REFER TO
INVESTIGATION REQUIREMENTS, EXTEND TILE
FLUE IF THE CHIMNEY HEIGHT IS INCREASED
PROVIDE BRICK CHIMNEY. FIELD VERIFY THE
EXISTING BRICK CORBEL AND RECONSTRUCTION
TO MATCH THE EXISTING COURSING AND CORBEL
OVERHANG DIMENSIONSVIF
TYP
CHIMNEY COVER:
MANF: HY-C CUSTOM SIZE
DESCRIPTION: 24 GAUGE REMOVABLE
100% 304 STAINLESS STEEL HOOD WITH
SCALLOPED CORNERS AND ROLL FORMED
EDGES, WITH,
24 GAUGE 100% 304 STAINLESS STEEL BASE
FLANGES FOR SECURE MOUNTING;
18 GAUGE MIN 3 4"
100% 304 STAINLESS STEEL EXPANDED
METAL MESH, 10" HIGH
SIZE: PROVIDE A CUSTOM SIZE A MINIMUM
OF 3" LARGER ON ALL SIZES OF THE EXIST.
FLUES
+ VIF
TOP OF CHIMNEY
CONTRACTOR SHALL VERIFY THE
EXISTING HEIGHT AND
RECONSTRUCT TO MATCH THE
EXISTING HEIGHT OR INCREASE THE
HEIGHT AS REQUIRED TO MEET THE
MINIMUM CODE REQUIREMENT OF
THE FOLLOWING:
· 3'-0" MIN ABOVE THE ROOF LINE
· 2'-0" ABOVE THE POINT 10'-0"
AWAY
· CHIMNEY COVER IS NOT
INCLUDED IN THE ABOVE MIN.
DIMENSIONS
POURED CONCRETE CAP. MATCH EXISTING SIZE
AND SETBACK. MIN. 3000 PSI. SLOPE TOP
SURFACE FOR POSITIVE DRAINAGE. IF THE
EXACT SIZE IS NOT KNOW DUE TO POOR
CONDITION PROVIDE A MIN. 4" THICK CAP WITH A
1" OVERHAND AND DRIP
CHIMNEY REINFORCING, PROVIDE TYP.:
· HORIZONTAL LADDER REINFORCING 9 GAUGE
SIDE AND CROSS RODS STAINLESS STEEL
TYPE 304 - AT 16" O.C VERT.
· ANCHOR TO BUILDING STRUCTURAL FRAMING
AT EACH FLOOR AND ROOF
NOTE:
CONTRACTOR SHALL RECONSTRUCT
THE CHIMNEY TO BE IN CONFORMANCE
WITH NFPA 211 AND MADE SUITABLE TO
THE APPLIANCES TO BE VENTED PER
REFERENCE SECTION G2427.5 OF THE
RESIDENTIAL CODE. PROVIDE SIGN AT
POINT OF VENT INTO CHIMNEY"
CHIMNEY IS FOR APPLIANCES THAT
BURN NATURAL GAS ONLY. DO NOT
CONNECT SOLID OR LIQUID BURNING
APPLIANCES OR INCINERATORS
FLUE LINER SHALL BE IN CONFORMANCE
WITH ASTM C 315
MIN. 12"
MAX 4"
AIR-
SPACE
2"
AIRSPACE REQUIRED FOR THERMAL
MOVEMENT OF FLUE LINER - DO NOT BRIDGE
OR FILL THE AIRSPACE WITH ANY MATERIAL
8" M
IN
FR
O
M H
IG
H
P T
(W H
ER
R
E
AP
PL
IC
AB
LE
EPDM WALL TRANSITION
CONTINUOUS 1" WIDE
TERMINATION BAR
BONDING ADHESIVE
LAP SEALANT
60 MIL EDPM MEMBRANE
ROOFING FULLY ADHERED
ON PLYWOOD SHEATHING
EXISTING WOOD
ROOF FRAMING
FACE OF CHIMNEY
7ATERMINATION BAR DETAIL
TYP. ROOF SECTION 6A
R -4
M
IN
. 7
INSULATION BAFFLE
FASTEN TO FACE OF
WOOD JOIST
PROVIDE SPRAY
FOAM INSULATION
FULLY ADHERED 60
MIL EPDM SINGLE
PLY ROOF
MEMBRANE
4" EXTERIOR GRADE
CDX PLYWOOD T & G
SHEATHING
EXISTING WOOD
ROOF JOISTS
EXISTING GYPSUM
WALL BOARD
TO REMAIN
EXISTING WOOD
CEILING
JOISTS
ROOF AND CHIMNEY
SECTIONS
AND
DETAILS
A-401
4245 UNION ROAD, SUITE 210
BUFFALO, NEW YORK 14225
P: 716.923.0133 F: 716.923.0136
No. REVISIONS DATE
DRAWING TITLE:
DRAWING No.
architectural, p.c.
architecture planning consulting
- 11-30-23
DATE: 11-30-23
SCALE: AS SHOWN
DRAWN BY: DHH
CHECKED BY:
PROJECT No: 23-023
ISSUED FOR 100% REVIEW
NYS OFFICE FOR PEOPLE
WITH DISABILITIES
1200 EAST AND WEST ROAD
WEST SENECA, NY 14224
CHIMNEY & ROOF
REPLACEMENT
LOCATED AT:
328 BUFFALO STREET
GOWANDA, NY 14070
REISSUED PER OWNER'S COMMENTS 1-3-24-
REISSUED PER OWNER'S COMMENTS 1-30-24-
AutoCAD SHX Text
SCALE :
AutoCAD SHX Text
SCALE :
AutoCAD SHX Text
NTS
AutoCAD SHX Text
SCALE :
AutoCAD SHX Text
NTS
AutoCAD SHX Text
SCALE :
AutoCAD SHX Text 1 1/2" = 1'-0''
AutoCAD SHX Text
SCALE :
AutoCAD SHX Text 1 1/2" = 1'-0''
AutoCAD SHX Text
SCALE :
AutoCAD SHX Text 1 1/2" = 1'-0''
AutoCAD SHX Text
SCALE :
AutoCAD SHX Text 1 1/2" = 1'-0''
AutoCAD SHX Text
SCALE :
AutoCAD SHX Text 1 1/2" = 1'-0''
AutoCAD SHX Text
SCALE :
AutoCAD SHX Text 1 1/2" = 1'-0''
AutoCAD SHX Text
XXXXXX
AutoCAD SHX Text
SCALE :
AutoCAD SHX Text 1 1/2" = 1'-0''
AutoCAD SHX Text
SCALE :
AutoCAD SHX Text 3" = 1'-0''
AutoCAD SHX Text
ZAXIS ARCHITECTURAL P.C.
THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, ARE THE PROPERTY OF ZAXIS ARCHITECTURAL P.C. UNAUTHORIZED REPRODUCTION, ALTERATION OR ADDITION TO ANY DRAWING, DESIGN, SPECIFICATION, PLAN OR REPORT IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN AUTHORIZATION OF ZAXIS ARCHITECTURAL P.C. IS PROHIBITED BY SECTION 7209, PROVISION 2 OF THE NEW YORK STATE EDUCATION LAW.
DIVISION 1 - GENERAL REQUIREMENTS
1A. GENERAL NOTES
1. THE PROJECT CONSISTS OF RENOVATIONS TO THE PROPERTY LOCATED AT: 328 BUFFALO STREET, GOWANDA, NEW
YORK 14070.
2. THE CONTRACT DOCUMENTS ARE PREPARED BY ZAXIS ARCHITECTURAL, P. C., 4245 UNION ROAD, SUITE 210, BUFFALO, NEW YORK 14225. ANY CHANGES TO THE CONTACT DOCUMENTS SHALL REQUIRE APPROVAL FROM ZAXIS
ARCHITECTURAL, P.C., THE OWNER AND OPDD.
3. THE WORK OF THE CONTRACTOR SHALL INCLUDE LABOR, MATERIALS, TOOLS, EQUIPMENT, SERVICES, ETC.
NECESSARY OR INCIDENTAL TO HIS/HER PORTION OF THE WORK SHOWN ON THE DRAWINGS AND HEREIN SPECIFIED. SHOP DRAWINGS AND/OR SAMPLES SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW FOR ALL
WORK OR MATERIALS REQUIRING FABRICATION, QUALITY APPROVAL, OR COLOR SELECTION.
4. THE CONTRACTOR SHALL ORDER AND HAVE ALL MATERIALS AVAILABLE BEFORE STARTING HIS/HER WORK, TO INSURE THAT ONCE THE WORK IS STARTED, IT SHALL PROCEED CONTINUOUSLY UNTIL COMPLETE.
5. THE CONTRACTOR SHALL ASCERTAIN THE LOCATION OF ALL UTILITY LINES AND TAKE PROPER PRECAUTION NOT TO DISTURB ANY EXISTING UTILITIES UNLESS AUTHORIZED. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ANY
DAMAGE TO UTILITY LINES DURING THE PROCESS OF WORK UNDER THE CONTRACT.
6. THE CONTRACTOR SHALL CAREFULLY EXAMINE THE DRAWINGS AND SPECIFICATIONS AND VERIFY THE PROVISIONS ARE ADEQUATE FOR THE PROPER INSTALLATION OF EACH ITEM. SHOULD THERE BE ANY CONDITION THAT WILL PREVENT A THOROUGHLY SATISFACTORY INSTALLATION, HE/SHE SHALL NOTIFY THE ARCHITECT OR OWNER, PRIOR TO BEGINNING WORK. FAILURE OF NOTIFICATION WILL CONSTITUTE ACCEPTANCE OF THE CONDITIONS, AND THE CONTRACTOR SHALL MAKE ANY NECESSARY CHANGES TO PROPERLY ACCOMMODATE EACH ITEM AT HIS/HER
COST.
7. ALL WORK MUST COMPLY WITH NEW YORK STATE BUILDING CONSTRUCTION CODE, AISC CODE, ACI BUILDING CODE, AWI CODE, ASTM STANDARDS AND ANY OTHER APPLICABLE CODE, RULES AND REGULATION BY AGENCIES HAVING
JURISDICTION. WHERE CODES OVERLAP, COMPLY WITH THE MORE STRINGENT REQUIREMENTS.
8. THE CONTRACTOR SHALL MAINTAIN INSURANCE WHICH WILL PROTECT HIM/HER FROM LIABILITY UNDER WORKMEN'S COMPENSATION ACTS AND OTHER EMPLOYEE BENEFITS ACTS IN ACCORDANCE WITH THE LAWS OF NEW YORK STATE, AND FROM LIABILITY FOR DAMAGES BECAUSE OF BODILY INJURY, INCLUDING DEATH AND
PROPERTY DAMAGE.
9. CONTRACTOR IS TO REVIEW DRAWINGS AND EXISTING SITE CONDITIONS AND DIMENSIONS FOR SCOPE OF THE WORK INVOLVED. CONTRACTOR IS TO INCLUDE, IN HIS/HER PROPOSAL, ALL ITEMS, MATERIALS, ETC. TO ACHIEVE
THE DESIGN CONCEPT AS SHOWN ON THE DRAWINGS.
10. CONTRACTOR IS TO INCLUDE IN HIS/HER PROPOSAL ALL ADDITIONAL MATERIALS AND LABOR AS REQUIRED TO
WORK AROUND EXISTING CONDITIONS.
11. CONTRACTOR IS RESPONSIBLE FOR ALL MEANS, METHODS, LABOR PROCEDURES AND SAFETY PRECAUTIONS FOR
COMPLETING WORK.
12. THE COST OF ALL TEMPORARY ELECTRICAL ENERGY AND WATER, AND COSTS FOR INSTALLATION OF TEMPORARY SERVICE LINES REQUIRED FOR COMPLETION OF THE PROJECT SHALL BE BORNE BY THE GENERAL CONTRACTOR.
13. ALL WORKMANSHIP MUST BE IN THE BEST PRACTICE OF THE TRADE AS DETERMINED BY THE ARCHITECT OR
OWNER. ANY WORK NOT MEETING THESE STANDARDS WILL BE REJECTED.
14. WHERE A SPECIFIC MANUFACTURER'S PRODUCT IS IDENTIFIED, THAT PRODUCT SHALL BE DEEMED THE “BASIS OF DESIGN” AND ALL MATERIALS AND WORK MUST COMPLY WITH THE MANUFACTURER'S STRICT RECOMMENDATIONS FOR INSTALLATION AND/OR COORDINATION. IT IS THE CONTRACTOR'S RESPONSIBILITY TO OBTAIN THE WRITTEN
INSTRUCTIONS AND TO FOLLOW THEM.
DIVISION 7 - THERMAL AND MOISTURE PROTECTION
7A. SEALANTS:
1. COMPATIBILITY: PROVIDE JOINT SEALERS, JOINT FILLERS AND OTHER RELATED MATERIALS THAT ARE COMPATIBLE WITH ONE ANOTHER AND WITH JOINT SUBSTRATES UNDER SERVICE AND APPLICATION CONDITIONS, AS
DEMONSTRATED BY TESTING AND FIELD EXPERIENCE.
2. COLORS: PROVIDE COLOR OF EXPOSED JOINT SEALERS AS SELECTED BY ARCHITECT FROM MANUFACTURER'S
STANDARD COLORS.
3. SILICONE SEALANT BY DOW CORNING #795 OR #790 OR APPROVED EQUAL.
4. MISCELLANEOUS MATERIALS
A. PRIMER: AS RECOMMENDED BY JOINT SEALER MANUFACTURE WHERE REQUIRED FOR ADHESION OF SEALANT
TO JOINT SUBSTRATES INDICATED.
B. PLASTIC FORM JOINT FILLERS: PREFORMED, COMPRESSIBLE, RESILIENT, NONWAXING, NONEXTRUDING STRIPS OF FLEXIBLE, NONGASSING PLASTIC FOAM OF MATERIAL INDICATED BELOW; NONABSORBENT TO WATER AND GAS; AND OF SIZE, SHAPE AND DENSITY TO CONTROL SEALANT DEPTH AND OTHERWISE CONTRIBUTE TO
PRODUCING OPTIMUM SEALANT PERFORMANCE.
1) EITHER OPEN_CELL POLYURETHANE FOAM OF CLOSED_CELL POLYETHYLENE FOAM, UNLESS OTHERWISE INDICATED, SUBJECT TO APPROVAL OF SEALANT MANUFACTURE, FOR COLD_APPLIED SEALANTS ONLY.
C. ELASTOMERIC TUBING JOINT FILLERS; NEOPRENE, BUTYL, EPDM, OF SILICONE TUBING COMPLYING WITH ASTM D 1056, NONABSORBENT TO WATER AND GAS, CAPABLE OF REMAINING RESILIENT AT TEMPERATURES, DOWN TO 26 F (_15 C). PROVIDE PRODUCTS WITH LOW COMPRESSION SET AND OF SIZE AND SHAPE TO PROVIDE A SECONDARY SEAL, TO CONTROL SEALANT DEPTH, AND OTHERWISE CONTRIBUTE TO OPTIMUM SEALANT
PERFORMANCE.
1) COMPLY WITH JOINT SEALER MANUFACTURER'S INSTRUCTIONS APPLICABLE TO PRODUCTS AND
APPLICATIONS INDICATED.
DIVISION 6 - WOOD AND PLASTICS
6A. ROUGH CARPENTRY
1. THE TERM "LUMBER" SHALL INCLUDE ALL ROUGH CARPENTRY WOODWORK TEMPORARY AND PERMANENT. ALL LUMBER SHALL BE TRADE AND GRADE MARKED, OR ACCOMPANIED BY A GRADING CERTIFICATE OF THE ASSOCIATION UNDER WHOSE RULES IT WAS GRADED AND SHIPPED AND AN AFFIDAVIT CERTIFYING ALL SUCH LUMBER DELIVERED TO THIS
PROJECT TO BE OF THE KIND AND GRADE SPECIFIED.
2. ALL LUMBER SHALL BE WELL_SEASONED AND AIR OR KILN DRIED. FRAMING LUMBER SHALL BE DELIVERED TO THE JOB SITE WITH MOISTURE CONTENT NOT EXCEEDING 19 PERCENT AS CERTIFIED BY THE SUPPLIER.
3. LUMBER SHALL CONFORM TO COMMERCIAL ASSOCIATION GRADES AND SIZES AS NOTED IN SIMPLIFIED PRACTICE RECOMMENDATION R_16 ISSUED BY THE BUREAU OF STANDARDS, DEPARTMENT OF COMMERCE, WASHINGTON, D.C.
ALL LUMBER FOR GROUNDS, BLOCKING, ETC. TO BE HEMLOCK, DOUGLAS FIR OR SOUTHERN PINE. ALL FRAMING LUMBER TO BE STRUCTURAL GRADE NO 2, MINIMUM ALLOWABLE FIBER STRESS IN BEDDING 1,200 PSI, DOUGLAS FIR OR
SOUTHERN PINE.
4. GLUE FOR ALL WORK _ WATERPROOF TYPE.
5. ROUGH HARDWARE, EXCEPT AS OTHERWISE SPECIFIED HEREIN, SHALL BE AS REQUIRED FOR PROPER EXECUTION OF WORK IN THIS SECTION AND SHALL BE HOT_DIPPED GALVANIZED STEEL OR OTHER APPROVED NON_CORROSIVE METAL.
6. FURNISH AND INSTALL ALL WOOD FOR SECURING ALL INDICATED ITEMS THROUGHOUT BUILDING, INCLUDING GROUNDS REQUIRED BY ITEMS FURNISHED BY OTHERS. ALL LUMBER TO BE EVEN, PLUMB, STRAIGHT AND SECURED BY
APPROVED METHOD AND FOR INTENDED PURPOSE.
7. PROVIDE ALL ROUGH HARDWARE NECESSARY IN CONNECTION WITH ROUGH CARPENTRY, ROUGH HARDWARE SHALL INCLUDE THREADED DOWELS, SCREWS, BOLTS (ALL TYPES), WASHERS, ANCHORS FOR MASONRY, PLASTER AND CONCRETE, CUPS AND OTHER SUCH FASTENERS AND MISCELLANEOUS TRIM THAT MAY BE PURCHASED WITHOUT
FURTHER FABRICATION.
8. ALL MEMBERS SHALL BE ADEQUATELY FASTENED TOGETHER TO PREVENT RELATIVE MOVEMENT AT JOINTS UNDER THE
MAXIMUM LOAD FOR WHICH THE MEMBERS ARE SIZED.
9. FRAMING NAILS SHALL BE UNCOATED COMMON NAILS OF SUFFICIENT LENGTH TO PENETRATE 12 DIAMETERS INTO
HOLDING MEMBER.
10. ALL WORK SHALL BE TRUE, PLUMB, LEVEL AND ACCURATELY CUT AND FIT.
11. PLYWOOD SHALL BE ERECTED AND FASTENED TO FRAMING MEMBERS IN ACCORDANCE WITH THE PUBLISHED
RECOMMENDATIONS OF THE APA.
6. WARRANTY
A. MANUFACTURER'S WARRANTY: FURNISH GAF-ELK MATERIALS CORPORATION: LIFETIME LIMITED WARRANTY.
B. WARRANTY SUPPLEMENT: PROVIDE MANUFACTURER'S SUPPLEMENTAL WARRANTY GAF-ELK MATERIALS CORPORATION:LIFETIME TRANSFERABLE WARRANTY WITH SMART CHOICE PROTECTION WITH NON PRORATED
MATERIAL AND INSTALLATION LABOR COVERAGE
1) FIRST TEN YEARS.
7. EXAMINATION
A. VERIFY THAT ROOF PENETRATIONS AND PLUMBING STACKS ARE IN PLACE AND FLASHED TO DECK SURFACE.
B. VERIFY DECK SURFACES ARE DRY AND FREE OF RIDGES, WARPS, OR VOIDS.
8. INSTALLATION
A. PLACE EAVE EDGE AND GABLE EDGE METAL FLASHING TIGHT WITH FASCIA BOARDS. WEATHER-LAP JOINTS 2
INCHES. SECURE FLANGE WITH NAILS SPACED 8 INCHES ON CENTER.
B. APPLY GAF: WEATHER WATCH MINERAL SURFACE LEAK BARRIER WATERPROOFING SHINGLE UNDERLAYMENT
OVER THE ENTIRE ROOF SURFACE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
9. INSTALLATION - PROTECTIVE UNDERLAYMENT
A. ROOF SLOPE 4:12 OR GREATER: INSTALL ONE LAYER ASPHALT FELT SHINGLE UNDERLAYMENT
PERPENDICULAR TO SLOPE OF ROOF AND LAP MINIMUM 4 INCHES.
B. WEATHER-LAP AND SEAL WATERTIGHT WITH ASPHALT ROOFING CEMENT ITEMS PROJECTING THROUGH OR
MOUNTED ON ROOF. AVOID CONTACT OF SOLVENT-BASED CEMENTS.
10. INSTALLATION - METAL FLASHING
C. WEATHER-LAP JOINTS AS INDICATED ON THE DRAWINGS.
D. SEAL WORK PROJECTING THROUGH OR MOUNTED ON ROOFING WITH ASPHALT ROOFING CEMENT AND MAKE
WEATHER-TIGHT.
11. INSTALLATION - ASPHALT SHINGLES
A. INSTALL SHINGLES IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS FOR PRODUCT TYPE AND
APPLICATION SPECIFIED.
12. PROTECTION OF FINISHED WORK
A. DO NOT PERMIT TRAFFIC OVER FINISHED ROOF SURFACE.
7D. FASCIA AND VENTILATED SOFFIT MATERIAL:
1. SOFFIT TO BE EQUAL TO ATAS INTERNATIONAL INC. MODEL: WIND-LOK MPV 120 SMOOTH NON-VENTED. . WALL
THICKNESS TO BE 0.032" ALUMINUM MIN. COLOR; TO BE WHITE - MATCH EXISTING
2. FASCIA TO BE EQUAL TO ATAS INTERNATIONAL INC. MINIMUM 0.032" ALUMINUM WITH KYNAR FINISH. COLOR; TO
MATCH EXISTING
7E. GUTTERS, DOWNSPOUTS AND ACCESSORIES:
1. GUTTERS: SHALL BE .032” ALUMINUM “OGEE” STYLE, 6” GUTTERS. SUPPORT WITH STRAPS FINISHED TO MATCH GUTTER. ALL CORNERS SHALL BE FACTORY MITERED AND SEALED WEATHERTIGHT. GUTTER COLOR TO MATCH
EXISTING.
2. DOWNSPOUTS: SHALL BE CORRUGATED RECTANGLE, .032” ALUMINUM, FINISHED TO MATCH GUTTER. PROVIDE AN INSTALL ALL METAL HANGERS FROM SAME MATERIAL AS GUTTERS DOWNSPOUTS AND ANCHORS.
7B. ROOF SYSTEM
1. PROVIDE (FURNISH AND INSTALL) .060 FULLY ADHERED SINGLE PLY (EDPM) MEMBRANE, OVER PLYWOOD DECK AS MANUFACTURED BY CARLISLE SYNTEC SYSTEMS (BASIS OF DESIGN). PROVIDE ALL FASTENERS, FLASHINGS, SEALANTS AND ACCESSORIES FOR A COMPLETE WEATHERTIGHT INSTALLATION. INSTALLATION IS TO BE
EXECUTED IN STRICT ACCORDANCE WITH MANUFACTURER'S STANDARD DETAILS AND PUBLISHED
SPECIFICATIONS.
2. THE ROOFING SYSTEM SHALL BE SINGLE-PLY, INSTALLED ONLY BY A ROOF CONTRACTING FIRM WHICH HAS BEEN
LICENSED BY THE ROOFING SYSTEM MATERIALS MANUFACTURER.
3. ALL FLASHING MATERIAL SHALL BE PROVIDED BY MEMBRANE MANUFACTURER.
4. TERMINATION BAR, TRANSITIONS, SPLICE ADHESIVES, LAP SEALANTS, BONDING ADHESIVES, ETC. SHALL BE
FURNISHED BY MEMBRANE MANUFACTURER.
5. FOLLOW MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION REQUIREMENTS FOR EACH INSTALLATION
PROCEDURE.
6. THE ROOFING SYSTEM SHALL BE CLASS "A" AS RATED BY FACTORY MUTUAL.
7. THE MEMBRANE MANUFACTURER SHALL ISSUE A MINIMUM FIFTEEN (15) YEAR WARRANTY.
8. MANUFACTURER'S WARRANTY: FURNISH 20 YEAR WARRANTY.
DIVISION 2 - SELECTIVE DEMOLITION
2A. SUMMARY
1. SECTION INCLUDES DEMOLITION AND REMOVAL OF SELECTED PORTIONS OF BUILDING OR STRUCTURE.
2B. FIELD CONDITIONS
1. OWNER WILL OCCUPY PORTIONS OF BUILDING IMMEDIATELY ADJACENT TO SELECTIVE DEMOLITION AREA.
CONTRACTOR SHALL PROVIDE, TO THE GREATEST EXTENT POSSIBLE, TEMPORARY ACCOMMODATIONS FOR OWNER
DURING DEMOLITION FOR NECESSARY UTILITIES.
2C. EXAMINATION
1. VERIFY THAT ANY ADJACENT UTILITIES HAVE BEEN DISCONNECTED AND CAPPED BEFORE STARTING DEMOLITION
OPERATIONS.
2. SURVEY EXISTING CONDITIONS AND CORRELATE WITH REQUIREMENTS INDICATED TO DETERMINE EXTENT OF
SELECTIVE DEMOLITION REQUIRED.
3. WHEN UNANTICIPATED MECHANICAL, ELECTRICAL OR STRUCTURAL ELEMENTS CONFLICT WITH INTENDED FUNCTION
OR DESIGN ARE ENCOUNTERED, INVESTIGATE AND SUBMIT TO FIELD REPRESENTATIVE.
2E. PREPARATION
1. SITE ACCESS: CONDUCT SELECTIVE DEMOLITION AND DEBRIS REMOVAL OPERATIONS TO ENSURE MINIMUM INTERFERENCE WITH ROADS, WALKWAYS, ETC. REPAIR ALL LAWN AREAS AFFECTED BY DEMOLITION/CONSTRUCTION.
2. TEMPORARY FACILITIES: PROVIDE TEMPORARY BARRICADES AND OTHER PROTECTION REQUIRED TO PREVENT INJURY
TO PEOPLE AND DAMAGE TO BUILDINGS.
2F. SELECTIVE DEMOLITION, GENERAL
1. GENERAL: DEMOLISH AND REMOVE EXISTING CONSTRUCTION ONLY TO THE EXTENT REQUIRED BY NEW
CONSTRUCTION.
2G. DISPOSAL
1. GENERAL: EXCEPT FOR ITEMS OR MATERIALS INDICATED TO REMAIN, REMOVE DEMOLISHED MATERIALS FROM SITE.
2. TRANSPORT DEMOLISHED MATERIALS OFF OWNER'S PROPERTY AND LEGALLY DISPOSE OF THEM.
6. WARRANTY
A. MANUFACTURER'S STANDARD LIMITED LIFETIME WARRANTY.
7. PRODUCTS
A. MANUFACTURERS
1) BASIS-OF-DESIGN PRODUCT: SUBJECT TO COMPLIANCE WITH
REQUIREMENTS, PROVIDE:
1. MANUFACTURER: HUNTSMAN BUILDING SOLUTIONS
2. PRODUCT: SPRAY APPLIED RIGID POLYURETHANE FOAM
INSULATION SYSTEM: HEATLOK - HFO PRO
B. MATERIALS
1) GENERAL: PROVIDE INSULATING MATERIALS THAT COMPLY WITH
REQUIREMENTS AND WITH REFERENCED STANDARDS.
2) SPRAY FOAM INSULATION: MEDIUM-DENSITY, CONFORMING TO THE
FOLLOWING:
a) ASTM D1622: CORE DENSITY: 2.0 - 2.4 1B/FT³
b) ASTM C518: AGED THERMAL RESISTANCE (FOR 1 INCH OF
MATERIAL) (R-VALUE/INCH @75 DEG F): 7.4 FT² H°F/BTU
c) ASTM E283: AIR LEAKAGE @ 75 PA @1": <0.02 L/SM²
d) ASTM E2178: AIR PERMEANCE @ 75 PA @1": <0.02 L/SM²
e) ASTM E96: WATER VAPOR PERMEANCE: CLASS II VAPOR RETARDER
PER IBC SECTION 202 @1", 0.91 PERMS
CLASS II VAPOR RETARDER @ </= 1 PERM - 1"
f) ASTM D 2842: WATER ABSORPTION (VOLUME): 0.3%
g) ASTM D1621 COMPRESSIVE STRENGTH : 31 PSI
h) ASTM D1623: TENSILE STRENGTH: 44PSI
i) ASTM D2126: DIMENSIONAL STABILITY @ 158°f (70° C) 97% rh (168
HOURS): -3.7 (% VOLUME CHANGE)
j) VOC EMISSIONS: UL ENVIRONMENTAL (GREENGUARD GOLD)
k) ASTM C1338: FUNGI RESISTNACE: NO FUNGAL GROWTH
l) ASTM D 2856: CLOSED CELL CONTENT: 98%
m) ASTM C1029: STANDARD SPECIFICATION FOR SPRAY APPLIED RIGID
CELLULAR POLYURETHANE THERMAL INSULATION: TYPE II
COMPLIANT
n) ASTM E84: SURFACE BURNING CHARACTERISTICS, (4" THICK):
CLASS 1
n)· FLAME SPREAD INDEX: 12 n)· SMOKE DEVELOPMENT: 350-400
o) AC 377 APPENDIX X: IGNITION BARRIER FOR USE IN ATTICS
WITHOUT A PRESCRIPTIVE IGNITION BARRIER OR INTUMESCENT
COATING
p) NFPA 285: COMPLIANT WITH EXTERIOR WALLS OF TYPE I,II,III,IV
BUILDINGS OF ANY HEIGHT
q) NFPA 286: THERMAL BARRIER COMPLIANT WITH IBC AND IRC AS
INTERIOR FINISH WITHOUT THERMAL BARRIER WHEN COATED WITH
DC-315 AT 18 MILS WET FILM, 12 MILS DRY FILM THICKNESS OR
BLAZLOK AT 18 MILS WET FILM, 12 MILS DRY FILM THICKNESS
C. SOURCE QUALITY CONTROL
1) INSULATION PRODUCT COMPONENTS PRODUCED IN AN ISO 9001
REGISTERED FACTORY.
1. EXECUTION
A. EXAMINATION
1) EXAMINE SUBSTRATES AND CONDITIONS, UNDER WHICH WORK IS TO BE
PERFORMED. DO NOT PROCEED UNTIL UNSATISFACTORY CONDITIONS
HAVE BEEN CORRECTED.
2) REVIEW PLACEMENT AREA TO DETERMINE FINAL LOCATION WILL NOT
BE WITHIN 3 INCHES OF ANY HEAT SOURCE WHERE THE TEMPERATURE
WILL EXCEED 180 DEG F PER ASTM C 411 OR IN ACCORDANCE WITH
AUTHORITIES HAVING JURISDICTION.
B. PREPARATION
1) CLEAN SUBSTRATES AND CAVITIES OF LOOSE MATERIALS CAPABLE OF
INTERFERING WITH INSULATION PLACEMENT.
C. INSTALLATION
1) INSTALL IN ACCORDANCE WITH MANUFACTURER'S WRITTEN
INSTRUCTIONS.
2) APPLY AS RECOMMENDED BY MANUFACTURER TO THICKNESS AS
INDICATED ON THE DRAWINGS
3) EQUIPMENT USED TO APPLY THE FOAM INSULATION SHALL HAVE FIXED
RATIO POSITIVE DISPLACEMENT PUMPS APPROVED BY THE
MANUFACTURER
4) INSTALL PRIMER ON OILY SURFACES AND GALVANIZED STEEL
D. REPAIRS
1) ANY REPAIRS MUST BE EFFECTED BY A MANUFACTURER CERTIFIED
INSTALLER
E. PROTECTION
1) PROTECT INSTALLED INSULATION FROM DAMAGE DUE TO HARMFUL
WEATHER EXPOSURES, PHYSICAL ABUSE, AND OTHER CAUSES.
PROVIDE TEMPORARY COVERINGS WHERE INSULATION IS SUBJECT TO
ABUSE.
F. CERTIFICATION
1) THE INSULATION INSTALLERS SHALL PROVIDE A CERTIFICATION LISTING
THE TYPE, MANUFACTURER AND R-VALUE OF INSULATION INSTALLED IN
EACH ELEMENT OF THE BUILDING THERMAL ENVELOPE. FOR THE
SPRAYED POLYURETHANE FOAM (SPF) INSULATION, THE INSTALLED
THICKNESS SHALL BE LISTED ON THE CERTIFICATE. THE INSULATION
INSTALLER SHALL SIGN, DATE AND POST THE CERTIFICATE IN A
CONSPICUOUS LOCATION ON THE JOB SITE. THIS CERTIFICATE SHOULD
BE POSTED JUST INSIDE THE ATTIC ACCESS OPENING SO THAT IT IS
READILY OBSERVABLE FOR INSPECTION.
7F. SPRAY FOAM INSULATION
1. SUBMITTALS
A. PRODUCT DATA FOR TYPE OF INSULATION PRODUCT SPECIFIED.
B. PRODUCT TEST REPORTS PERFORMED BY A QUALIFIED THIRD-PARTY TESTING AGENCY
EVIDENCING COMPLIANCE OF INSULATION PRODUCTS WITH SPECIFIED REQUIREMENTS
INCLUDING THOSE FOR THERMAL RESISTANCE, FIRE-TEST-RESPONSE
CHARACTERISTICS, WATER-VAPOR TRANSMISSION, AND OTHER PROPERTIES, BASED ON
COMPREHENSIVE TESTING OF CURRENT PRODUCTS.
C. EVALUATION REPORT: EVIDENCE OF COMPLIANCE OF FOAM-PLASTIC INSULATIONS WITH
INTERNATIONAL BUILDING CODE (IBC), INTERNATIONAL RESIDENTIAL CODE (IRC),
INTERNATIONAL ENERGY CONSERVATION CODE (IECC).
D. MANUFACTURER'S CERTIFICATE CERTIFYING INSULATION PROVIDED MEETS OR
EXCEEDS SPECIFIED REQUIREMENTS.
E. CERTIFICATE PROVIDING EVIDENCE THE MATERIAL MEETS AIR BARRIER ASSOCIATION
OF AMERICA (ABAA) REQUIREMENTS.
F. INSTALLER'S CERTIFICATE SHOWING THE MANUFACTURER'S INSTALLATION
CERTIFICATION.
G. SAMPLE WARRANTY
2. QUALITY ASSURANCE
A. MANUFACTURER'S QUALIFICATIONS: PRODUCT PRODUCED IN A MANUFACTURER'S
REGISTERED FACTORY.
B. SINGLE SOURCE RESPONSIBILITY: SINGLE SOURCE PRODUCT FROM ONE
MANUFACTURER.
C. INSTALLER QUALIFICATIONS:
1) ENGAGE A MANUFACTURER'S LICENSED CONTRACTOR (INSTALLER) WHO HAS BEEN
TRAINED AND CERTIFIED BY THE MANUFACTURER.
2) INSTALLER MUST BE BUILDING PERFORMANCE INSTITUTE (BPI) CERTIFIED.
D. FIRE-TEST-RESPONSE CHARACTERISTICS: PROVIDE MATERIALS SPECIFIED AS
DETERMINED BY TESTING IDENTICAL PRODUCTS PER TEST METHOD INDICATED BELOW
BY A TESTING AND INSPECTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING
JURISDICTION. IDENTIFY MATERIALS WITH APPROPRIATE MARKINGS OF APPLICABLE
TESTING AND INSPECTING AGENCY.
1) SURFACE-BURNING CHARACTERISTICS: ASTM E 84
2) RATED WALL ASSEMBLY TESTING: ASTM E119 AND NFPA 285
E. TOXICITY/HAZARDOUS MATERIALS
1) PROVIDE PRODUCTS THAT ARE “LOW-EMITTING”.
2) PROVIDE PRODUCTS THAT CONTAIN NO PBDE'S .
3) PROVIDE PRODUCTS THAT CONTAIN NO UREA-FORMALDEHYDE.
3. DELIVERY, STORAGE, AND HANDLING
A. COMPLY WITH MANUFACTURERS WRITTEN INSTRUCTIONS FOR HANDLING AND
PROTECTION PRIOR TO AND DURING INSTALLATION.
B. STORE BOTH COMPONENTS IN A TEMPERATURE CONTROLLED AREA BETWEEN 60 AND
85 DEGREES F. DO NOT ALLOW PRODUCT TO FREEZE.
C. USE ONLY THOSE COMPONENTS THAT ARE SUPPLIED BY THE MANUFACTURER.
5. PROJECT CONDITIONS
A. MAINTAIN ENVIRONMENTAL CONDITIONS (TEMPERATURE, HUMIDITY, AND VENTILATION)
WITHIN LIMITS RECOMMENDED BY MANUFACTURER FOR OPTIMUM RESULTS. DO NOT
INSTALL PRODUCTS UNDER ENVIRONMENTAL CONDITIONS OUTSIDE MANUFACTURE'S
ABSOLUTE LIMITS
B. VENTILATE INSULATION APPLICATION AREA IN ACCORDANCE WITH SPRAY FOAM
COALITION'S GUIDANCE ON BEST PRACTICES FOR THE INSTALLATION OF SPRAY
POLYURETHANE FOAM.
C. PROTECT WORKERS AS RECOMMENDED BY THE SPRAY FOAM COALITION'S GUIDANCE
ON BEST PRACTICES FOR THE INSTALLATION OF SPRAY POLYURETHANE FOAM.
D. PROTECT ADJACENT SURFACES, WINDOWS, EQUIPMENT AND SITE AREAS FROM
DAMAGE OF OVERSPRAY
DIVISION 4 - MASONRY
4A. MORTAR
1. PORTLAND CEMENT: ASTM C 150, TYPE I OR II, EXCEPT TYPE III MAY BE USED FOR COLD-WEATHER CONSTRUCTION.
PROVIDE NATURAL COLOR OR WHITE CEMENT AS REQUIRED TO PRODUCE REQUIRED MORTAR COLOR.
2. MASONRY CEMENT: ASTM C 91.
3. HYDRATED LIME: ASTM C 270, TYPE N. (REPOINTING) TYPE S (NEW)
4. AGGREGATE FOR MORTAR: ASTM C 144, EXCEPT FOR JOINTS LESS THAN 1/4 INCH USE AGGREGATE GRADED WITH 100
PERCENT PASSING THE NO. 18 SIEVE.
A. WHITE MORTAR AGGREGATES: NATURAL WHITE SAND OR GROUND WHITE STONE.
5. WATER: CLEAN AND POTABLE.
4B. CLAY MASONRY UNITS
1. PROVIDE UNITS WITHOUT CORES OR FROGS AND WITH ALL EXPOSED SURFACES FINISHED FOR ENDS OF SILLS, CAPS, AND SIMILAR EXPOSED APPLICATIONS THAT EXPOSE BRICK SURFACES THAT OTHERWISE WOULD BE CONCEALED FROM
VIEW.
2. FACE BRICK STANDARD: ASTM C 216, MODULAR SIZE AS FOLLOWS:
A. MANUFACTURER: MATCH EXISTING
B. COLOR: MATCH EXISTING
C. GRADE SW
D. COMPRESSIVE STRENGTH: 3000 PSI
E. TYPE FBX. (MINIMUM VARIATION IN SIZE AND COLOR)
F. COURSE INSTALLATION PATTERN: MATCH EXISTING
3 TIES AND ANCHORS: AS INDICATED ON THE DRAWINGS
4. EMBEDDED FLASHING MATERIAL: FLEXIBLE COPPER-LAMINATED FLASHING. 5-OZ/ SF.FT. COPPER SHEET BONDED BETWEEN TWO LAYERS OF GLASS FIBER CLOTH. BASIS-OF-DESIGN SHALL BE: TOTAL FLASH AS MANUFACTURED BY MORTAR NET SOLUTIONS OR ARCHITECT APPROVED EQUIVALENT. PROVIDE PREFORMED CORNERS, END DAMS, AND
MATERIALS PRODUCED BY FLASHING MANUFACTURER.
5. MISCELLANEOUS MASONRY ACCESSORIES:
A. FORM JOINT REINFORCING FROM THE FOLLOWING:
1) GALVANIZED CARBON STEEL WELDED - WIRE UNITS PREFABRICATED WITH DEFORMED CONTINUOUS SIDE RODS AND PLAIN CROSS RODS INTO STRAIGHT LENGTHS. 9 GAUGE LADDER TYPE DESIGN. INSTALL AT 16" O.C. VERT..
HOHMANN & BARNARD INC. OR EQUAL.
6. REPOINTING
A. RAKE OUT JOINTS - REMOVE MORTAR FROM JOINT TO DEPTH OF 2 TIMES THE WIDTH BUT NOT LESS THAN 12". DO
NOT REMOVE UNSOUND MORTAR MORE THAN 2" DEEP - CONTACT ARCHITECT FOR DIRECTION
B. PROVIDE REVEALS WITH SQUARE BACKS AND EXPOSE BRICK MASONRY FOR CONTACT WITH REPOINTING MORTAR.
REMOVE DIRT AND DEBRIS.
C. DO NOT SPALL EDGES OF BRICK- REPLACE OR PATCH DAMAGED BRICK UNITS AS DIRECTED BY THE ARCHITECT.
D. RINSE JOINT SURFACE WITH WATER TO REMOVE DUST AND DEBRIS. TIME RINSING APPLICATION SO AT TIME OF
REPOINTING, JOINT SURFACES ARE DAMP BUT FREE OF STANDING WATER, IF RINSE WATER DRIES - DAMPEN JOINT E. PLACE MORTAR IN LAYERS NOT GREATER THAN 3 8". FULLY COMPACT EACH LAYER. DO NOT SPREAD MORTAR
BEYOND JOINT EDGES ONTO EXPOSED BRICK SURFACES
F. WHEN MORTAR IS THUMBPRINT HARD - TOOL JOINTS TO MATCH ORIGINAL APPEARANCE.
G. CURE MORTAR BY MAINTAINING DAMP CONDITION FOR AT LEAST 72 HOURS.
H. HAIRLINE CRACKING OR SEPARATION IS NOT ACCEPTABLE - REMOVE AND REPOINT
I. CLEAN EXCESS MORTAR FROM ALL SURFACES
7C. ROOF SYSTEM
1. MANUFACTURER
A. PROVIDE PRODUCTS MANUFACTURED BY GAF-ELK MATERIALS CORPORATION OR APPROVED EQUAL.
2. ASPHALT FIBER GLASS SHINGLES
A. TIMBERLINE HD SHINGLES: UL CERTIFICATION OF ASTM D3462; CONFORMS TO ASTM D3018 TYPE I - SELF-SEALING; ASTM D3161-03B, CLASS “F” WIND RESISTANCE (REGIONAL) ; ASTM D3161-99A WIND RESISTANCE; UL997 WIND RESISTANCE; UL 2390/ASTM D6381 CLASS “H” AND ASTM D7158 CLASS “H” WIND RESISTANCE; UL 790 CLASS A FIRE RESISTANCE; GLASS FIBER MAT BASE, CERAMICALLY COLORED/UV RESISTANT MINERAL SURFACE GRANULES ACROSS ENTIRE FACE OF SHINGLE; TWO-PIECE LAMINATED
SHINGLE.
1) WEIGHT: 220-240 POUNDS PER SQUARE (100 SQUARE FEET)
2) COLOR: TO BE MATCH EXISTING
3. SHEET MATERIALS
A. ROOF PROTECTION SHALL BE PROVIDED BY THE SAME MANUFACTURER AS THE ROOF SHINGLES: GAF-ELK MATERIALS CORPORATION; ASTM D 1970 SHEET BARRIER OF SELF-ADHERING RUBBERIZED ASPHALT MEMBRANE SHINGLE UNDERLAYMENT HAVING INTERNAL REINFORCEMENT, AND "SPLIT" BACK PLASTIC RELEASE FILM; PROVIDE MATERIAL WITH WARRANTY EQUAL IN DURATION TO THAT OF SHINGLES BEING
APPLIED.
1) GAF: WEATHER WATCH MINERAL SURFACE LEAK BARRIER
4. FLASHING MATERIALS
A. SHEET FLASHING: ASTM B 209; 0.025 IN THICK ALUMINUM, MILL FINISH.
B. BITUMINOUS PAINT: ACID AND ALKALI RESISTANT TYPE; BLACK COLOR.
5. ACCESSORIES
A. NAILS: STANDARD ROUND WIRE TYPE ROOFING NAILS, CORROSION RESISTANT; HOT DIPPED ZINC COATED STEEL, ALUMINUM, OR CHROMATED STEEL; MINIMUM 3/8 INCH HEAD DIAMETER; MINIMUM 11 OR 12 GAGE SHANK DIAMETER; SHANK TO BE OF SUFFICIENT LENGTH TO PENETRATE THROUGH ROOF SHEATHING.
1) PROVIDE ALUMINUM NAILS FOR ALL ALUMINUM FLASHING MATERIALS
B. ASPHALT ROOFING CEMENT: ASTM D 4586, TYPE I OR II.
4245 UNION ROAD, SUITE 210
BUFFALO, NEW YORK 14225
P: 716.923.0133 F: 716.923.0136
No. REVISIONS DATE
DRAWING TITLE:
SCALE: AS SHOWN
CHECKED BY:
DRAWING No.
architectural, p.c.
architecture planning consulting
SP-101
SPECIFICATIONS
ISSUED FOR 100% REVIEW
NYS OFFICE FOR PEOPLE
WITH DISABILITIES
1200 EAST AND WEST ROAD
WEST SENECA, NY 14224
DATE: 11-30-23
DRAWN BY: DHH
PROJECT No: 23-023
11-30-23
CHIMNEY & ROOF
REPLACEMENT
LOCATED AT:
328 BUFFALO STREET
GOWANDA, NY 14070
REISSUED PER OWNER'S COMMENTS 1-3-24-
REISSUED PER OWNER'S COMMENTS 1-30-24-
AutoCAD SHX Text
ZAXIS ARCHITECTURAL P.C.
THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, ARE THE PROPERTY OF ZAXIS ARCHITECTURAL P.C. UNAUTHORIZED REPRODUCTION, ALTERATION OR ADDITION TO ANY DRAWING, DESIGN, SPECIFICATION, PLAN OR REPORT IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN AUTHORIZATION OF ZAXIS ARCHITECTURAL P.C. IS PROHIBITED BY SECTION 7209, PROVISION 2 OF THE NEW YORK STATE EDUCATION LAW.
| 23-023 CS-101 COVER SHEET |
| Sheets and Views |
| COVER SHEET |
| 23-023 A-101 ROOF PLAN |
| Sheets and Views |
| A-101 ROOF PLAN |
| 23-023 A-401 ROOF AND CHIMNEY DETAILS |
| Sheets and Views |
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .