Drawings - Bid Documents.pdf

PDF 16 MB Posted

Attached to
Y1DZ--FY26: NRM (PROJ: 673-21-145) BB Construct New Bed Tower Connector
Solicitation number
36C24825R0163_1
Issued by

About this file

These are bid documents for a construction project to construct a new bed tower connector at the Veterans Affairs Medical Center (VAMC) in Tampa, Florida. The project number is 673-21-145, located at 13000 Bruce B. Downs Blvd. The project involves removing the existing ICU patient rooms and nurse station, and constructing a corridor to connect the Surgery area with the Bed Tower. The documents include comprehensive architectural, mechanical, electrical, plumbing, and fire protection plans for the second floor renovation, with detailed demolition and new work plans across multiple disciplines.

The bid documents are fully sprinklered and include extensive technical specifications adhering to numerous national codes and standards, including NFPA, International Building Code, and VA design guidelines. The project scope encompasses architectural modifications, HVAC system updates, electrical system reconfigurations, plumbing modifications, and fire alarm system integration. The drawings provide precise details on room layouts, equipment placement, demolition sequences, and new construction requirements, with specific attention to maintaining hospital operations and safety during the renovation process.

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SHEET INDEX

GI001

SHEET

NO. DRAWING TITLE

GENERAL

GI002

ARCHITECTURAL

SHEET

NO.

COVER SHEET

NOTES, ABBREVIATIONS AND LEGEND

CONSTRUCT NEW BED TOWER CONNECTOR

PROJECT NUMBER: 673-21-145

BID DOCUMENTS

VAMC TAMPA

13000 BRUCE B. DOWNS BLVD.

TAMPA, FL 33612

SECOND FLOOR DEMO PLANAD101

PLUMBING

PLUMBING, LEGEND, ABBREVIATIONS AND NOTESP001

MECHANICAL

MECHANICAL LEGEND, ABBREVIATIONS, AND NOTESM001

SECOND FLOOR HVAC DEMOLITION PLANMD101

M101

PARTIAL SECOND FLOOR OVERALL PLUMBING PLAN - DEMOLITIONPD101

ENLARGED SECOND FLOOR PLUMBING PLAN SECTION A - DEMOLITIONPD401

LOCATION MAP

NOT TO SCALE

AREA MAP

NOT TO SCALE

TRUE

NORTH

TRUE

NORTH

PLAN

NORTH

PLAN

NORTH

PROJECT LOCATION

PROJECT LOCATION

SECOND FLOOR HVAC NEW WORK PLAN

M501 MECHANICAL DETAILS, SCHEDULE, AND CONTROLS

ENLARGED SECOND FLOOR PLUMBING PLAN SECTION B - DEMOLITIONPD402

PARTIAL SECOND FLOOR OVERALL PLUMBING PLAN - NEW WORKP101

ENLARGED SECOND FLOOR PLUMBING SECTION A - NEW WORKP401

ENLARGED SECOND FLOOR PLUMBING SECTION B - NEW WORKP402

SECOND FLOOR DEMO RCPAD111

SECOND FLOOR PLANAE101

SECOND FLOOR RCPAE111

ELECTRICAL

ELECTRICAL GENERAL NOTES AND ABBREVIATIONSE-001

ELECTRICAL LEGENDE-002

ED101 SECOND FLOOR ELECTRICAL DEMOLITION PLAN

ED103 SECOND FLOOR LIGHTING DEMOLITION PLAN

AE501 PARTITION TYPES AND DETAILS

GI003 SECOND FLOOR PHASE ONE PLANS

AE601 SCHEDULES, NOTES AND DETAILS

EL101 SECOND FLOOR LIGHTING PLAN

MECHANICAL NOTESM002

FIRE PROTECTION

FIRE PROTECTION LEGEND, ABBREVIATIONS AND NOTESFP001

PARTIAL SECOND FLOOR OVREALL FIRE PROTECTION - DEMOLITIONFPD101

PARITAL SECOND FLOOR OVERALL FIRE PROTECTION - NEW FP101

GI004 SECOND FLOOR PHASE TWO PLANS

ED102 SECOND FLOOR SYSTEMS DEMOLITION PLAN

EP101 SECOND FLOOR ELECTRICAL PLAN

E-600 ELECTRICAL SCHEDULES

FIRE DETECTION AND ALARM

FIRE ALARM NOTES AND LEGENDFA001

FIRE ALARM DEMOLITION PLANFD101

FA101 FIRE ALARM FLOOR PLANS AND RISER

SECOND FLOOR LIFE SAFETY PLANLS101

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

DATE:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

BID DOCUMENTS

512 MEANS STREET NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date CheckedFULLY SPRINKLERED

STAMP

STE. 400

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

SJ MC/KB

673-21-145

10-27-2025REVISIONS:

A

B

C

D

E

F

CONSTRUCT NEW BED TOWER

CONNECTOR

13000 BRUCE B DOWNS BLVD

COVER SHEET

GI001

ARCHITECTURAL ABBREVIATIONSARCHITECTURAL LEGEND

GENERAL ARCHITECTURAL NOTES

GENERAL PROJECT NOTES

A

GA4

A301

A201

A401

ROOM

NAME

+ 0'-6"

F.E.C.

AIR CONDITIONING

ACOUSTICAL CEILING TILE

ABOVE FINISH FLOOR

ALUMINUM

BATT INSULATION

BOTTOM OF

CEMENTITIOUS BACKER BOARD

CEMENTITIOUS CRYSTALLINE WATERPROOFING

COLD-FORMED METAL FRAMING

CORNER GUARD

CENTERLINE

CONCRETE MASONRY UNIT

CASED OPENING

COMMUNICATION

CONCRETE

SEALED CONCRETE

CONTINUOUS

CONTRACTING OFFICER'S REPRESENTATIVE

CERAMIC TILE

CERAMIC TILE BASE

CARPET

DIAMETER

EXPANSION JOINT

ELECTRICAL

EPOXY FLOORING

EXPOSED STRUCTURE

ET CETERA

EXISTING

EXPOSED

FACTORY FINISH

FLOOR DRAIN

FIRE EXTINGUISHER CABINET

FIRE HOSE CABINET

FINISHED FLOOR

FINISH

FLOOR

FACE OF

FIELD VERIFY

FABRIC WALLCOVERING

GAGE

GRANITE

GYPSUM (WALL) BOARD

HANDICAPPED

HOLLOW METAL

HANDRAIL

HEATING VENTILATION AND AIR-CONDITIONING

MATERIAL

MAXIMUM

MECHANICAL

MANUFACTURER

MINIMUM

MASONRY OPENING

METAL

NOT IN CONTRACT

NOT TO SCALE

ON CENTER

OPPOSITE HAND

PLASTER

PLASTIC LAMINATE

PORCELAIN TILE

PAIR

PAINT

QUARRY TILE

RESILIENT BASE

REFRIGERATOR

REQUIRED

RESINOUS FLOORING

RESINOUS EPOXY WALL-CEILING

ROUGH OPENING

RUBBER FLOORING

RECESSED PAPER HOLDER

SEALED HIGH BUILD GLAZED COATING

SOLID CORE WOOD

SIMILAR

SPECIAL FACED

STAINLESS STEEL

STEEL

SUBSTRATE

SHEET VINYL

SOLID VINYL TILE

TELEPHONE

TOP OF

TYPICAL

UNLESS NOTED OTHERWISE

VINYL COMPOSITION TILE

VINYL WALL COVERING

WALL COVERING

WALL PROTECTION

WOOD

WELDED SEAM SHEET FLOORING

AC

AT

AFF

AL

BATT

BO

CBB

CCW

CFMF

CG

C

CMU

CO

COMM

CONC

SCONC

CONT

COR

CT

CTB

CP

DIA

EJ

ELEC

EPY

ES

ETC

EXIST

EXP

FAC FIN

FD

FEC

FHC

FF

FIN

FLR

FO

FV

FWC

GA

GRA

GYP BD/GWB

HC

HM

HR

HVAC

MATL

MAX

MECH

MFR

MIN

MO

MTL

NIC

NTS

OC

OH

PLS

PL

PT

PR

P

QT

RB

REF

REQ'D

RES

RES-W

RO

RF

RPH

SC

SCW

SIM

SP

SS

STL

SUBS

SV

SVT

TELE

TO

TYP

UNO

VCT

VWC

WC

WP

WD

WSF

L

FIRE EXTINGUISHER CABINET

ROOM NAME AND NUMBER

DOOR NUMBER

KEY NOTE

WINDOW TYPE

PARTITION TYPE

DETAIL CALLOUT

DETAIL NUMBER

SHEET WHERE DETAIL IS DRAWN

SECTION CALLOUT

VERTICAL ELEVATION

COLUMN CENTERLINE DESIGNATION

DEMOLITION KEY NOTE

DETAIL NUMBER

SHEET WHERE DETAIL IS DRAWN

INTERIOR ELEVATION CALLOUT

DETAIL NUMBER

SHEET WHERE DETAIL IS DRAWN

CARD READER/ CRASH RAILCR

HIGH-PRESSURE LAMINATEHPL

LUXURY VINYL TILELVT

EDGE OF DECKEOD

DOWNSPOUTDS

CONTROL JOINTCJ

DRINKING FOUNTAINDF

FIRE RETARDANT TREATEDFRT

EXTERIOR INSULATION FINISHING SYSTEMEIFS

WATER RESISTANTWR

J1

SECTION CUT

HEAD/JAMB/SILL DETAIL NUMBER EQUALEQ

CARPET TILECPT

REFLECTED CEILING PLANRCP

SOLID SURFACE MATERIALSSM

X1045 EQUIPMENT TAG

ALUMINUM COMPOSITE METAL PANELSACMP

A. DIMENSIONS, UNLESS OTHERWISE INDICATED, ARE TO:

• FACE OF EXISTING WALL SURFACE

• FACE OF MASONRY

• FACE OF WALL STUDS

• TOP OF SLAB

• TOP OF MASONRY

• ALIGN WALLS WITH EXISTING WHERE NOT OTHERWISE INDICATED.

B. COORDINATE WITH ALL DISCIPLINES DRAWINGS FOR ADDITIONAL REQUIREMENTS.

C. COORDINATE OPENINGS IN SLABS, ROOF, AND WALLS. WHERE HOLES IN EXISTING WALLS

AND SLABS ARE CREATED FOR PENETRATIONS, COORDINATE SIZE AND LOCATION. PATCH

HOLES CAUSED BY THE REMOVAL OF EQUIPMENT, PIPING, CONDUIT, DUCT, GRILLES, ETC.

WITH MATERIALS MATCHING EXISTING SLAB OR WALL IN STRUCTURE, MATERIAL,

THICKNESS, ALIGNMENT, GRADES, AND QUALITY.

D. COORDINATE AND PROVIDE GALVANIZED METAL BACKER PLATE OR SOLID FIRE

RETARDANT TREATED WOOD BLOCKING FOR WALL-MOUNTED ITEMS. COORDINATE

LOCATIONS WITH COR FOR GOVERNMENT PROVIDED/CONTRACTOR INSTALLED

EQUIPMENT AND ACCESSORIES.

E. `PROVIDE' IS DEFINED AS PROVIDING MATERIALS, DELIVERY, STORAGE, HANDLING,

INSTALLATION, ADJUSTMENT, AND CLEANING FOR THE ITEM INDICATED.

F. SEAL PIPE PENETRATIONS THROUGH SLABS, MASONRY, SMOKE RATED PARTITIONS AND

FIRE-RATED PARTITIONS WITH THE APPROPRIATE FIRESTOP TO MAINTAIN THE RATING OF

THE WALL OR SLAB. SUBMIT CUT SHEETS AND SPECIFICATIONS TO THE COR FOR

APPROVAL PRIOR TO INSTALLATION. PROVIDE UL LISTED ASSEMBLIES.

G. SKIM COAT ALL DAMAGED EXISTING WALL SURFACES THAT REQUIRE PAINTING.

H. REMOVED MATERIALS WHICH ARE INDICATED TO BE TURNED OVER TO THE COR SHALL BE

DELIVERED BY THE CONTRACTOR TO A PLACE INDICATED BY THE COR .

I. REMOVE COMPLETELY ALL MATERIALS AS INDICATED ON THE DRAWINGS AND AS

REQUIRED FOR CONSTRUCTION. EDGES AND FACES OF REMOVED AREAS SHALL BE

REPAIRED TO ACCEPT NEAT INSTALLATION OF CONSTRUCTION OR FINISHES. WHERE

EXISTING MATERIALS ARE TO BE REPLACED (WALLS, INSULATION, FLOORING, ETC.)

EXISTING MATERIALS, ADHESIVES, ETC. SHALL BE REMOVED AND EXPOSED SURFACES

SHALL BE PREPARED AS INDICATED OR SPECIFIED PRIOR TO INSTALLATION OF

MATERIALS.

J. PREVENT DAMAGE TO MATERIALS AND FINISHES TO REMAIN. REPAIR DAMAGES FROM

CONSTRUCTION ACTIVITIES TO EXISTING ITEMS TO REMAIN, AT NO ADDITIONAL COST

WHERE SUCH EXPOSED MATERIALS OR FINISHES TO REMAIN ARE DAMAGED.

K. CONTRACTOR SHALL DOCUMENT AND REPORT TO THE COR ANY PRE-EXISTING DAMAGE

OR UNSEALED PENETRATIONS AT THE START OF WORK.

A. THE CONTRACTOR SHALL BE PREPARED TO STOP ANY WORK AND CLEAN UP THE WORK AREA AS

DIRECTED IN MEDICAL SITUATIONS REQUIRING SUCH ACTION.

B. THE CONTRACTOR SHALL NOT ORDER OR INSTALL ANY MATERIALS OR EQUIPMENT UNTIL

SUBMITTALS FOR SUCH HAVE BEEN APPROVED.

C. ALL TOOLS AND MATERIALS USED IN THIS PROJECT SHALL BE PROPERLY SECURED AT ALL TIMES BY THE CONTRACTOR TO REDUCE THE POSSIBILITY OF ANY OF THESE TOOLS BEING A HAZARD TO

PATIENTS, VISITORS AND STAFF.

D. THE CONTRACTOR WILL BE RESPONSIBLE FOR ACQUIRING I.D. BADGES FOR EACH MEMBER OF HIS WORK FORCE. VALID FORMS OF I.D. ARE REQUIRED TO RECEIVE BADGES. COORDINATE WITH COR.

E. THE CONTRACTOR, AT HIS EXPENSE, WILL BE RESPONSIBLE FOR TRAINING EACH MEMBER OF HIS

WORK FORCE ON VA POLICIES FOR ON-SITE WORK BEFORE ANY MEMBER WILL BE ALLOWED TO

PERFORM WORK ON VA PREMISES.

F. ABSOLUTELY NO VA TOOLS, MATERIALS OR EQUIPMENT WILL BE LOANED OR GIVEN BY THE VA TO

ANY MEMBER OF THE CONTRACTOR'S WORK FORCE AT ANY TIME.

G. ANY SMOKE DETECTORS HAVING ANY POTENTIAL FOR EXPOSURE TO CONSTRUCTION SMOKE, DUST

AND DEBRIS SHALL BE SUITABLY PROTECTED TO PREVENT ACCIDENTAL ALARM DURING

CONSTRUCTION. ALL SUCH ACTION MUST BE FIRST COORDINATED AN CLEARED WITH THE COR AND THE VA SAFETY OFFICER. ALL FUNCTIONAL FIRE ALARM DEVICES SHALL BE ACTIVE WHENEVER THE

CONTRACTOR'S FORCES ARE NOT PRESENT IN THE WORK AREA.

H. THE CONTRACTOR MUST PROVIDE WRITTEN FIRE SAFETY CHECKLIST AT THE END OF EVERY WORK

DAY TO THE COR CERTIFYING THAT ALL WORK AREAS HAVE BEEN SURVEYED AND FOUND TO BE

SECURE, SAFE AND FREE OF ANY FLAMMABLE LIQUIDS.

I. CONTRACTOR SHALL COORDINATE ONLY WITH THE COR AND CONTRACTING OFFICER.

J. SEE SPECIFICATIONS SECTIONS 01 00 00 AND 01 35 26 FOR INTERIM LIFE SAFETY MEASURES.

K. ALL FINISH COLORS TO BE SELECTED BY COR/ VA INTERIOR DESIGNER WHERE NOT OTHERWISE

INDICATED. CONTRACTOR SHALL SUBMIT COLORS FROM THE MANUFACTURER'S FULL RANGE OF

COLORS.

L. PROVIDE 24"X24" ACCESS PANELS IN HARD CEILINGS WHERE DUCTS AND DAMPERS OR OTHER

PIPES REQUIRE ACCESS AS REQUIRED. COORDINATE EXACT LOCATIONS WITH THE COR.

M. THE CONTRACTOR SHALL NOT OPERATE ANY EXISTING VA EQUIPMENT WITHOUT AUTHORIZATION

FROM VAMC ENGINEERING SERVICE UNLESS AN EMERGENCY SITUATION OCCURS.

N. CONTRACTOR SHALL MAINTAIN ALL FIRE-RATED ASSEMBLIES WITHIN THE PROJECT AREA DURING

PERFORMANCE OF THE WORK.

O. CONTRACTOR SHALL PROVIDE AND MAINTAIN ALL REQUIRED EXIT LIGHTING AND SIGNAGE

REQUIRED FOR EGRESS WITHIN AND ADJACENT TO THE PROJECT AREA DURING PERFORMANCE OF THE WORK. SUBMITTAL FOR ALL EQUIPMENT AND MATERIAL MUST BE APPROVED BY COR PRIOR TO

PURCHASE/DELIVERY.

P. INDICATED EXISTING CONDITIONS ARE BASED UPON LIMITED FIELD INVESTIGATION AND DID NOT INCLUDE DESTRUCTIVE INVESTIGATION OR TESTING. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS INCLUDING DIMENSIONS OF THE INSTALLED CONSTRUCTION PRIOR TO COMMENCING WITH THE WORK. IF DISCREPANCIES ARE DISCOVERED, THE CONTRACTOR SHALL NOTIFY THE COR

FOR INTERPRETATION AND DIRECTION PRIOR TO PROCEEDING WITH THE WORK.

Q. COORDINATE WORK WITH EQUIPMENT SUPPLIER/ INSTALLER CONTRACTED SEPARATELY WITH THE GOVERNMENT. SUBMITTAL FOR ALL EQUIPMENT/ MATERIAL MUST BE APPROVED BY COR PRIOR TO

PURCHASE/ DELIVERY.

R. CONTRACTOR SHALL PROTECT ALL SITE AND BUILDING AREAS SUBJECT TO PROJECT-RELATED

VEHICULAR TRAFFIC AND DEMOLITION WORK.

S. THE CONTRACTOR SHALL DISPOSE OF ALL DEMOLISHED MATERIALS IN AN APPROVED. RECORD OF

WASTE, DISPOSAL MUST BE TURNED TO COR MONTHLY. OFFSITE LANDFILL EXCEPT WHERE

OTHERWISE REQUIRED FOR SALVAGE OR RECYCLING.

T. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS INCLUDING DIMENSIONS OF INSTALLED

CONSTRUCTION PRIOR TO COMMENCING WITH THE WORK. IN THE EVENT THAT ANY

DISCREPANCIES BETWEEN THE INDICATED WORK AND EXISTING CONDITIONS ARE DISCOVERED,

THE CONTRACTOR SHALL NOTIFY THE COTR FOR INTERPRETATON AND DIRECTION PRIOR TO

PROCEDING WITH THE WORK.

1 SIGNAGE TYPE

SCOPE OF WORK STATEMENT

A. REMOVE EXISTING ICU (PATIENT ROOMS AND NURSE STATION INCLUDING WALLS, FLOORS,

CEILINGS, AND OTHER ITEMS ASSOCIATED TO THEM AS NEEDED) AND CONSTRUCT A CORRIDOR TO

CONNECT SURGERY WITH BED TOWER IN ACCORDANCE WITH THE CONTRACT, VA TIL AND

STATEMENT OF WORK.

CODE, STANDARDS AND EXECUTIVE ORDERS

A. VA DESIGN GUIDES – TECHNICAL INFORMATION LIBRARY

B. PG 18-3 VA DESIGN AND CONSTRUCTION PROCEDURES, TOPIC 1

C. 2024 NPFA 1 FIRE CODE

D. 2022 NFPA 10 STANDARD FOR PORTABLE FIRE EXTINGUISHERS

E. 2025 NFPA 13 STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS

F. 2023 NFPA 70 NATIONAL ELECTRIC CODE (NEC)

G. 2025 NFPA 72 NATIONAL FIRE ALARM SIGNALING CODE

H. 2024 NFPA 90A INSTALLATION OF AIR-CONDITIONING AND VENTILATING SYSTEMS

I. 2024 NFPA 90B INSTALLATION OF WARM AIR HEATING AND AIR-CONDITIONING SYSTEMS

J. 2024 NFPA 99 HEALTHCARE FACILITIES CODE

K. 2024 NFPA 101 LIFE SAFETY CODE (LSC)

L. 2024 NFPA 220 STANDARD ON TYPES OF BUILDING CONSTRUCTION

M. 2022 NFPA 241 STANDARD FOR SAFE GUARDING CONSTRUCTION ALTERATION, AND DEMOLITION

OPERATIONS

N. 2024 INTERNATIONAL BUILDING CODE (IBC)

O. 2024 INTERNATIONAL PLUMBING CODE (IPC)

P. 2024 INTERNATIONAL MECHANICAL CODE (IMC)

Q. 2022 ASHRAE 90.1

R. 2024 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)

S. BARRIER FREE DESIGN STANDARD

T. ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS (ABAAS)

U. VA BARRIER FREE DESIGN GUIDE (PG-18-13)

V. RESOURCE CONSERVATION AND RECOVERY ACT (RCRA) (42 U.S.C.6901, ET SEQ)

W. THE NATIONAL ENERGY CONSERVATION POLICY ACT

X. EXECUTIVE ORDER 131468 PF APRIL 21, 2000, GREENING THE GOVERNMENT THROUGH LEADERSHIP IN

ENVIRONMENTAL MANAGEMENT.

Y. EXECUTIVE ORDER 13101 OF SEPTEMBER 14, 1998, GREENING THE GOVERNMENT

Z. THROUGH WASTE PREVENTION, RECYCLING, AND FEDERAL ACQUISITION; AND EXECUTIVE ORDER

13123 OF JUNE 1999, GREENING THE GOVERNMENT THROUGH EFFICIENT ENERGY MANAGEMENT.

MOUNTING HEIGHTS

PROVIDE BLOCKING AT ALL WALL MOUNTED EQUIPMENT AND ACCESSORIES

ACCESSIBILITY REQUIREMENTS

FRONT APPROACHES

HINGE-SIDE APPROACHES

LATCH-SIDE APPROACHES

USE EITHER

OPTION 1 OR

OPTION 2

ALL DOOR ASSEMBLIES SHALL BE CONSTRUCTED TO MEET THE

INDICATED MINIMUM CLEARANCES AS APPLICABLE.

1'-0" IF DOOR HAS BOTH

A CLOSER AND A

LATCH

5' -0

1'-6"

3' -6

4'-6"

4' -0

O P

TI

O

N

5' -0

OPTION 1

3'-0"

O P

TI

O

N

4' -6

OPTION 2

3'-6"

2'-0"

4' -0

2'-0"

3' -6

4' -0

4' -6

W / C

LO

S

E R

4' -0

W / C

LO

S

E R

W /C

LO

S

E R

A N

D L

A

TC

H

ALL WORK SHALL COMPLY WITH FEDERAL ABA,

LOCAL, AND STATE ACCESSIBILITY CODES AND

REQUIREMENTS.

DOOR LOCATIONS

TYPICAL DETAILS

TYP DOOR LOCATION

SEE DOOR SCHEDULE

6"

TYP

TYP. WALL PROTECTION, HANDRAIL/ CRASH RAIL INTERIOR

ELEVATION DIAGRAM

CRASH RAIL

HANDRAIL/ WALL GUARD

RETURNED TO WALL @ END

2"2"

2"

BASE AS SCHEDULED

CORNER GUARD

DOOR FRAME OR OPENING

3' -4

CL

FEC

TYPICAL SIGNAGE MOUTING HEIGHTS

A A

5' -0

4' -9

EQ EQ

2' -1

0"4' -0

WALL PROTECTION

UL DETAIL C-AJ-1254UL DETAIL W-L-2038

NOTE: ANY UL ASSEMBLY MEETING CRITERIA MAY

BE UTILIZED. ASSEMBLIES INDICATED ON THIS

SHEET ARE FOR INFORMATION ONLY.WALL

FLOOR

AND

WALL

FLOOR

AND

WALL

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

DATE:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

BID DOCUMENTS

512 MEANS STREET NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date CheckedFULLY SPRINKLERED

STAMP

STE. 400

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

SJ MC/KB

673-21-145

10-27-2025REVISIONS:

A

B

C

D

E

F

CONSTRUCT NEW BED TOWER

CONNECTOR

13000 BRUCE B DOWNS BLVD

NOTES, ABBREVIATIONS AND LEGENDS

GI002

CG CG CGCG CGCGCG CGCG CGCG CGCG

C G

C G

C G

C G

PHASE ONE PLAN LEGEND

EXISTING CONSTRUCTION

TO REMAIN

EXISTING CONSTRUCTION

TO BE REMOVED

AREA IN SCOPE OF WORK

TEMPORARY PATH OF TRAVEL

TEMPORARY ICRA

BARRIER/ ENTRANCE DOOR

PHASE ONE PLAN GENERAL NOTES

A. PROVIDE ICRA BARRIERS AND ENTRANCE DOORS AS REQUIRED AND INDICATED ON FLOOR PLANS.

COORDINATE LOCATIONS WITH COR. REFER TO DETAILS 11/AE501 AND 12/AE501. BASIS OF DESIGN:

STARC REALWALL, ONE HOUR RATED, CLASS IV SYSTEMS WITH HEPA FILTRATIION AND MONITORING AS DIRECTED BY THE COR. CONTACT: MAX DANSKY; OFFICE: 207-844-2789; CELL: 978-502-9689; EMAIL:

MDANSKY@STARCSYSTEMS.COM.

B. DEMOLISH AND INSTALL WORK LOCATED WITHIN THE TEMPORARY BARRIERS.

C. COORDINATE AND SCHEDULE AFTER HOURS AND WEEKEND WORK WITH COR.

EXISTING DOOR AND FRAME ASSEMBLY TO REMAIN.

PHASE ONE DEMO PLAN KEY NOTES #

CONSTRUCTION

PHASE ONE PLAN KEY NOTES #

COMPLETE WORK ON EXISITNG DOOR AND FRAME ASSEMBLY TO REMAIN AS

PART OF PHASE ONE. THIS WORK SHALL BE LIMITED TO AFTER HOURS AND

WEEKENDS AT THE DIRECTION OF THE COR.

LIMITS OF WORK TO BE

REMOVED

SMOKE PARTITION

1-HOUR FIRE BARRIER

EXIST 2-HOUR FIRE BARRIER

EXIST SMOKE PARTITION

EXIST 1-HOUR FIRE BARRIER

EXIST SMOKE BARRIER

8 9 10 11 12 13 14 15 16 17

A

B

C

STORAGE

2D-251A

STORAGE

2D-251

H.A.C.

2D-252A

OPERATING

ROOM #5

2D-239

OPERATING

ROOM #6

2D-240

OPERATING

ROOM #7

2D-241

CORRIDOR

C2-37-1

MENS

VESTIBULE

V2-04-01

RESTROOM

2D-249

WOMENS

LOCKER

ROOM

2D-247

WOMENS

VESTIBULE

V2-03-01

OFFICE

2D-245

RECEPTION

2D-246

PATIENT

ROOM #14

ISOLATION

2D-252V

RT WORK

ROOM

2D-252W

PATIENT

ROOM #15

ISOLATION

2D-252U

CORRIDOR

C2-47-1

RESTROOM

2D-253A

LOUNGE

2D-253

STAIR #1

S2-01-1

ELECTRICAL

2D-254

TELEPHONE

2D-255C

SIGNAL

2D-255B

FIRE

2D-55A

COMM

2D-252S

EQUIPMENT

STORAGE

2D-252T

CLEAN

LINEN

2D-259

ELECTRICAL

2D-258

SICU &

SURGERY

WAITING

ROOM

2D-256

CONSULT

2D-257

COMM

2D-256A

RESTROOM

2D-256B

ON CALL

2D-288

RESTROOM

2D-252P

PATIENT

ROOM #4

2D-252L

RETAIL

STORE

2A-201

FREEZER

2A-205D

REFRIGERATOR

2A-205C

OFFICE

2A-205A

COMPUTER

ROOM

2A-205B

KITCHEN

2A-205

FOOD

COURT

2A-214A

PIZZA

SHOP

2A-210

CORRIDOR

C2-49-1

KITCHEN

STORAGE

2A-209

GENERAL

STORAGE

2A-207

GENERAL

STORAGE

2A-206

PATIENT

ROOM #5

2D-252K

PATIENT

ROOM #6

2D-252J

PATIENT

ROOM #7

2D-252I

PATIENT

ROOM #8

2D-252H

HEAD

NURSE

2D-252G

PATIENT

ROOM #9

2D-252F

PATIENT

ROOM #10

2D-252E

PATIENT

ROOM #11

2D-252D

PATIENT

ROOM #12

2D-252C

CORRIDOR

C2-43-1

CONNECTOR

ENTRY TO NEW

BED TOWER

PATIENT

ROOM #13

2D-252B

NURSE

STATION

2D-252

TEMPORARY ACCESS CORRIDOR

DURING CONSTRUCTION

D

E

ROOF

BELOW

OPEN TO

BELOW

ELEVATOR

LOBBY

2D-201

CORRIDOR

C2-35-1

CORRIDOR

C2-48-1 CORRIDOR

C2-42-1

CORRIDOR

C2-42A-1

CORRIDOR

C2-01-1

OPEN TO

BELOW

ROOF

BELOW

INTERIOR

ROOF

BELOW

8 9 10 11 12 13 14 15 16 17

A

B

C

D

E

STORAGE

2D-251A

STORAGE

2D-251

H.A.C.

2D-252A

OPERATING

ROOM #5

2D-239

OPERATING

ROOM #6

2D-240

OPERATING

ROOM #7

2D-241

CORRIDOR

C2-37-1

MENS

VESTIBULE

V2-04-01

RESTROOM

2D-249

WOMENS

LOCKER

ROOM

2D-247

WOMENS

VESTIBULE

V2-03-01

OFFICE

2D-245

RECEPTION

2D-246

PATIENT

ROOM #14

ISOLATION

2D-252V

RT WORK

ROOM

2D-252W

PATIENT

ROOM #15

ISOLATION

2D-252U

CORRIDOR

C2-47-1

RESTROOM

2D-253A

LOUNGE

2D-253

STAIR #1

S2-01-1

ELECTRICAL

2D-254

TELEPHONE

2D-255C

SIGNAL

2D-255B

FIRE

2D-55A

COMM

2D-252S

EQUIPMENT

STORAGE

2D-252T

CLEAN

LINEN

2D-259

ELECTRICAL

2D-258

SICU &

SURGERY

WAITING

ROOM

2D-256

CONSULT

2D-257

COMM

2D-256A

RESTROOM

2D-256B

ON CALL

2D-288

RESTROOM

2D-252P

RETAIL

STORE

2A-201

FREEZER

2A-205D

REFRIGERATOR

2A-205C

OFFICE

2A-205A

COMPUTER

ROOM

2A-205B

KITCHEN

2A-205

FOOD

COURT

2A-214A

PIZZA

SHOP

2A-210

CORRIDOR

C2-49-1

KITCHEN

STORAGE

2A-209

GENERAL

STORAGE

2A-207

GENERAL

STORAGE

2A-206

CONNECTOR

ENTRY TO NEW

BED TOWER

NURSE

STATION

2D-252

TEMPORARY ACCESS CORRIDOR

DURING CONSTRUCTION

ROOF

BELOW

OPEN TO

BELOW

ELEVATOR

LOBBY

2D-201

CORRIDOR

C2-35-1

CORRIDOR

C2-48-1

CORRIDOR

C2-42-1

CORRIDOR

C2-01-1

6' -0

" M

IN

EQUIPMENT

STORAGE

2D-252B

EQUIPMENT

STORAGE

2D-252C

CORRIDOR

C2-44-2

CORRIDOR

C2-44-1

OPEN TO

BELOW

ROOF

BELOW

INTERIOR

ROOF

BELOW

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

DATE:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

BID DOCUMENTS

512 MEANS STREET NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date CheckedFULLY SPRINKLERED

STAMP

STE. 400

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

SJ MC/KB

673-21-145

10-27-2025REVISIONS:

A

B

C

D

E

F

CONSTRUCT NEW BED TOWER

CONNECTOR

13000 BRUCE B DOWNS BLVD

SECOND FLOOR PHASE ONE PLANS

GI003

3/32" = 1'-0"GI003

1 SECOND FLOOR PHASE ONE DEMOLITION PLAN

3/32" = 1'-0"GI003

2 SECOND FLOOR PHASE ONE CONTRUCTION PLAN

CGCG

CG CG CGCG CGCGCG CGCGCG CGCG CGCG

C G

C G

C G

C G

TRUE

NORTH

PLAN

NORTH

PROJECT AREA

KEY PLAN

NTS

PHASE TWO PLAN LEGEND

EXISTING CONSTRUCTION

TO REMAIN

EXISTING CONSTRUCTION

TO BE REMOVED

AREA IN SCOPE OF WORK

TEMPORARY PATH OF TRAVEL

PHASE TWO PLAN GENERAL NOTES

A. PROVIDE ICRA BARRIERS AND ENTRANCE DOORS AS REQUIRED AND INDICATED ON FLOOR PLANS.

COORDINATE LOCATIONS WITH COR. REFER TO DETAILS 11/AE501 AND 12/AE501. BASIS OF DESIGN: STARC REALWALL, ONE HOUR RATED, CLASS IV SYSTEMS WITH HEPA FILTRATION AND MONITORING AS DIRECTED BY

THE COR. CONTACT: MAX DANSKY; OFFICE: 207-844-2789; CELL: 978-502-9689; EMAIL:

MDANSKY@STARCSYSTEMS.COM.

B. DEMOLITION AND WORK INCLUDED IN PHASE TWO WILL BE SEQUENCED AND COMPLETED AFTER HOURS AND WEEKENDS. WORK TO BE SCHEDULED, COORDINATED AND APPROVED BY THE COR TO MAINTAIN HOSPITAL OPERATIONS. THE CONTRACTOR SHALL REVIEW MEANS AND METHODS AND ADJUST AS REQUIRED TO

ACCOMPLISH THE WORK. PROPOSED SEQUENCING IS PROVIDED BELOW.

a. CONSTRUCT REMAINING PARTITION NOT INCLUDED IN PHASE ONE.

b. REMOVE EXISTING FLOORING AND WALL BASE; AND INSTALL AND EXTEND FLOOR AND WALL BASE

MATERIAL.

c. COMPLETE CEILING DEMOLITION WORK AND INSTALL CEILING SYSTEM.

d. COMPLETE WALL PROTECTION AND CORNER GUARD WORK.

e. COMPLETE REMAINING FINISH WORK.

REMAINING FLOOR AND CEILING DEMOLITION AND CONSTRUCTION TO BE COMPLETED

AFTER HOURS AND WEEKENDS AS DIRECTED BY THE COR.

PHASE TWO DEMO PLAN KEY NOTES #

CONSTRUCTION

PROVIDE AND INSTALL REMAINING PERMANENT CORRIDOR WORK. PROVIDE

TEMPORARY CONSTRUCTION AS REQUIRED FOR CORRIDOR TO REMAIN IN OPERATION

DURING NORMAL HOSPITAL HOURS. PATCH AND REPAIR ADJACENT CONSTRUCTION

WITH MATCHING MATERIALS AND FINISHES IMPACTED BY THE WORK. WORK IN THIS

AREA IS LIMITED TO AFTER HOURS AND WEEKENDS AS DIRECTED BY THE COR. REFER

TO GENERAL NOTES THIS SHEET FOR PROPOSED SEQUENCING AND ADDITIONAL ICRA

BARRIER INFORMATION.

PHASE TWO PLAN KEY NOTES #

LIMITS OF WORK TO BE

REMOVED

LIMITS OF WORK TO BE

INSTALL

SMOKE PARTITION

1-HOUR FIRE BARRIER

EXIST 2-HOUR FIRE BARRIER

EXIST SMOKE PARTITION

EXIST 1-HOUR FIRE BARRIER

EXIST SMOKE BARRIER

8 9 10

A

B

C

ON CALL

2D-288

FREEZER

2A-205D

REFRIGERATOR

2A-205C

OFFICE

2A-205A

COMPUTER

ROOM

2A-205B

KITCHEN

2A-205

GENERAL

STORAGE

2A-206

CONNECTOR

ENTRY TO NEW

BED TOWER

8 9 10 11 12 13 14 15 16 17

A

B

C

D

E

STORAGE

2D-251A

STORAGE

2D-251

H.A.C.

2D-252A

OPERATING

ROOM #5

2D-239

OPERATING

ROOM #6

2D-240

OPERATING

ROOM #7

2D-241

CORRIDOR

C2-37-1

MENS

VESTIBULE

V2-04-01

RESTROOM

2D-249

WOMENS

LOCKER

ROOM

2D-247

WOMENS

VESTIBULE

V2-03-01

OFFICE

2D-245

RECEPTION

2D-246

PATIENT

ROOM #14

ISOLATION

2D-252V

RT WORK

ROOM

2D-252W

PATIENT

ROOM #15

ISOLATION

2D-252U

CORRIDOR

C2-47-1

RESTROOM

2D-253A

LOUNGE

2D-253

STAIR #1

S2-01-1

ELECTRICAL

2D-254

TELEPHONE

2D-255C

SIGNAL

2D-255B

FIRE

2D-55A

COMM

2D-252S

EQUIPMENT

STORAGE

2D-252T

CLEAN

LINEN

2D-259

ELECTRICAL

2D-258

SICU &

SURGERY

WAITING

ROOM

2D-256

CONSULT

2D-257

COMM

2D-256A

RESTROOM

2D-256B

ON CALL

2D-288

RETAIL

STORE

2A-201

FREEZER

2A-205D

REFRIGERATOR

2A-205C

OFFICE

2A-205A

COMPUTER

ROOM

2A-205B

KITCHEN

2A-205

PIZZA

SHOP

2A-210

KITCHEN

STORAGE

2A-209

GENERAL

STORAGE

2A-206

CONNECTOR

ENTRY TO NEW

BED TOWER

NURSE

STATION

2D-252

PERMANENT ACCESS CORRIDOR

PATH OF TRAVEL

ROOF

BELOW

OPEN TO

BELOW

ELEVATOR

LOBBY

2D-201

CORRIDOR

C2-35-1

CORRIDOR

C2-48-1

CORRIDOR

C2-42-1

CORRIDOR

C2-01-1

CORRIDOR

C2-44-2

EQUIPMENT

STORAGE

2D-252B

EQUIPMENT

STORAGE

2D-252C

OPEN TO

BELOW

ROOF

BELOW

INTERIOR

ROOF

BELOW

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

DATE:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

BID DOCUMENTS

512 MEANS STREET NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date CheckedFULLY SPRINKLERED

STAMP

STE. 400

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

SJ MC/KB

673-21-145

10-27-2025REVISIONS:

A

B

C

D

E

F

CONSTRUCT NEW BED TOWER

CONNECTOR

13000 BRUCE B DOWNS BLVD

SECOND FLOOR PHASE TWO PLANS

GI004

0' 4' 8' 16' 24'

SCALE: 1/8" = 1' - 0"

3/32" = 1'-0"GI004

1 SECOND FLOOR PHASE TWO DEMOLITION PLAN

3/32" = 1'-0"GI004

2 SECOND FLOOR PHASE TWO CONSTRUCTION PLAN

CG CG CGCG CGCGCG CG CGCG CGCG CGCG

FEC

FEC

FEC

C G

C G

C G

C G

8 9 10 11 12 13 14 15 16 17

A

B

C

D

E

199' - 0"

198' - 0"

LOUNGE

2D-253

ELECTRICAL

2D-254

SICU &

SURGERY

WAITING

ROOM

2D-256

EQUIPMENT

STORAGE

2D-252T

PATIENT

ROOM #15

ISOLATION

2D-252U

PATIENT

ROOM #14

ISOLATION

2D-252V

RT WORK

ROOM

2D-252W

EQUIPMENT

STORAGE

2D-252B

EQUIPMENT

STORAGE

2D-252C

STORAGE

2D-251A

STORAGE

2D-251

MENS

VESTIBULE

V2-04-01

H.A.C.

2D-252A

RESTROOM

2D-249

RESTROOM

2D-248

WOMENS

LOCKER

ROOM

2D-247

CORRIDOR

C2-47-1

RESTROOM

2D-253A

STAIR #1

S2-01-1

RESTROOM

2D-256B

COMM

2D-256A

SOILED

LINEN

2D-260

PATIENT

ROOM #1

2D-252R

CLEAN

LINEN

2D-259

ELECTRICAL

2D-258

CONSULT

2D-257

COMM

2D-252S

CORRIDOR

C2-44-1

CORRIDOR

C2-44-2

RETAIL

STORE

2A-201

ON CALL

2D-288

RESTROOM

2D-252P

CORRIDOR

C2-49-1

FREEZER

2A-205D

COMPUTER

ROOM

2A-205B

OFFICE

2A-205A

GENERAL

STORAGE

2A-206

GENERAL

STORAGE

2A-207

LOCKER

ROOM

2A-208

KITCHEN

STORAGE

2A-209

PIZZA

SHOP

2A-210

PATIENT

ROOM #2

2D-252Q

CORRIDOR

C2-01-1

ELEVATOR LOBBY

2D-201

CORRIDOR

C2-35-1

CORRIDOR

C2-48-1

CORRIDOR

C2-37-1

STAIR 1

LEVEL 2

ICU PATIENT

ROOM 8

CONNECTOR

ENTRY TO NEW

BED TOWER

STAIR #2

S2-02-1

FOOD

COURT

2A-214A

188' - 0"

132'-8"

ROOF

BELOW

OPEN TO

BELOWM

AX. DISTANCE

R 75'-0"

MAX. DISTANCE

R 75'-0"

OPEN TO

BELOW

ROOF

BELOW

INTERIOR

ROOF

BELOW

EXISTING CONSTRUCTION TO REMAIN

CONSTRUCTION

EXIT SIGN

TOTAL TRAVEL DISTANCE

FULLY RECESSED FIRE

EXTINGUISHER CABINET FEC

SMOKE PARTITION

1-HOUR FIRE BARRIER

STARTING POINT OF TRAVEL

LIFE SAFETY LEGEND

TOTAL TRAVEL DISTANCE

TRAVEL DISTANCE TO EXIT = 199' - 0" < 200' - 0"

FULLY RECESSED EXIST FIRE

EXTINGUISHER CABINETFEC

EXIST 2-HOUR FIRE BARRIER

EXIST SMOKE PARTITION

EXIST 1-HOUR FIRE BARRIER

EXIST SMOKE BARRIER

KEY PLAN

NTS

PROJECT AREA

TRUE

NORTH

PLAN

NORTH

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

DATE:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

BID DOCUMENTS

512 MEANS STREET NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date CheckedFULLY SPRINKLERED

STAMP

STE. 400

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

SJ MC/KB

673-21-145

10-27-2025REVISIONS:

A

B

C

D

E

F

CONSTRUCT NEW BED TOWER

CONNECTOR

13000 BRUCE B DOWNS BLVD

SECOND FLOOR LIFE SAFETY PLAN

LS101

1" = 10'-0"LS101

1 SECOND FLOOR LIFE SAFETY PLAN

DEMOLITION PLAN LEGEND

EXISTING CONSTRUCTION

TO REMAIN

EXISTING CONSTRUCTION

TO BE REMOVED

LIMITS OF PROJECT AREA

UNLESS NOTED OTHERWISE

EXISTING WINDOW TO BE

REMOVED

LIMITS OF WORK TO BE

REMOVED

EXIST 2-HOUR FIRE BARRIER

EXIST SMOKE PARTITION

EXIST 1-HOUR FIRE BARRIER

EXIST SMOKE BARRIER

TRUE

NORTH

PLAN

NORTH

9 10 11 12 13 14 15 16 17

A

B

C

STORAGE

2D-251A

STORAGE

2D-251

H.A.C.

2D-252A

CORRIDOR

C2-37-1

MENS

VESTIBULE

V2-04-01

RESTROOM

2D-249

PATIENT

ROOM #14

ISOLATION

2D-252V

RT WORK

ROOM

2D-252W

PATIENT

ROOM #15

ISOLATION

2D-252U

COMM

2D-252S

EQUIPMENT

STORAGE

2D-252T

CLEAN

LINEN

2D-259

ON CALL

2D-288

RESTROOM

2D-252P

PATIENT

ROOM #4

2D-252L

FREEZER

2A-205D

OFFICE

2A-205A

COMPUTER

ROOM

2A-205B

CORRIDOR

C2-49-1

GENERAL

STORAGE

2A-207

GENERAL

STORAGE

2A-206

PATIENT

ROOM #5

2D-252K

PATIENT

ROOM #6

2D-252J

PATIENT

ROOM #7

2D-252I

PATIENT

ROOM #8

2D-252H

HEAD

NURSE

2D-252G

PATIENT

ROOM #9

2D-252F

PATIENT

ROOM #10

2D-252E

PATIENT

ROOM #11

2D-252D

PATIENT

ROOM #12

2D-252C

CORRIDOR

C2-43-1

CONNECTOR

ENTRY TO NEW

BED TOWER

PATIENT

ROOM #13

2D-252B

NURSE

STATION

2D-252

D

ROOF

BELOW

OPEN TO

BELOW

3 4

REF

TYP

TYP

TYP

TYP

A S

R E

Q 'D

TYP9999 99

9 9

TYP

NURSE

STATION

2D-252

CORRIDOR

C2-44-1

OPEN TO

BELOW

ROOF

BELOW

INTERIOR

ROOF

BELOW

PROJECT AREA

KEY PLAN

NTS

DEMO PLAN GENERAL NOTES

A. REFER TO GENERAL PROJECT NOTES, ARCHITECTURAL NOTES, SYMBOLS,

LEGENDS AND ABBREVIATIONS ON SHEET GI002.

B. THE CONTRACTOR SHALL REMOVE ALL EXISTING CONSTRUCTION REQUIRED

TO INSTALL WORK.

C. REFER TO AND COORDINATE WORK WITH OTHER DISCIPLINE'S DRAWINGS FOR

ADDITIONAL INFORMATION AND REQUIREMNETS.

D. REMOVE EXISTING FINISHES AND WALL MOUNTED ITEMS/ ACCESSORIES/

EQUIPMENT IN PROJECT AREA AS REQUIRED TO INSTALL NEW WORK UNLESS

NOTED OTHERWISE.

E. REMOVE EXISTING DAMAGED SUBSTRATE AND UNDERLAYMENT AS REQUIRED

TO INSTALL NEW WORK.

REMOVE EXISTING WINDOW ASSEMBLY.

REMOVE EXISTING SLIDING DOOR AND WINDOW ASSEMEBLY.

REMOVE EXISTING NURSE STATION MILLWORK.

REMOVE EXISTING COUNTER TOP, CASEWORK, FIXTURES AND OTHER WALL

MOUNTED EQUIPMENT/ ACCESSORIES.

REMOVE EXISTING POWER COLUMN AND MONITOR BOOM. TURN OVER TO THE

GOVERMENT AND RELOCATE TO A COR APPROVED LOCATION.

REMOVE EXISTING HANDRAILS AND CRASHRAILS.

LINE INDICATES LIMIT OF FLOORING FINISH TO BE REMOVED AND PREPARED TO

INSTALL WORK. FLOORING BEYOND THIS LINE TO REMAIN.

EXISTING DOOR AND FRAME ASSEMBLY TO REMAIN.

REMOVE EXISTING FINISHES AND WALL MOUNTED ITEMS/ ACCESSORIES/

FIXTURES/ EQUIPMENT AS REQUIRED TO INSTALL WORK UNLESS NOTED

OTHERWISE.

REMOVE EXISTING WALL FINISHES AND WALL PROTECTION AT WALLS AND

COLUMNS IN PROJECT AREA AS REQUIRED TO INSTALL THE WORK.

DEMO PLAN KEY NOTES #

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

DATE:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

BID DOCUMENTS

512 MEANS STREET NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date CheckedFULLY SPRINKLERED

STAMP

STE. 400

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

SJ MC/KB

673-21-145

10-27-2025REVISIONS:

A

B

C

D

E

F

CONSTRUCT NEW BED TOWER

CONNECTOR

13000 BRUCE B DOWNS BLVD

SECOND FLOOR DEMO PLAN

AD101

0' 4' 8' 16' 24'

SCALE: 1/8" = 1' - 0"

1/8" = 1'-0"AD101

1 SECOND FLOOR DEMOLITON PLAN

DEMO RCP LEGEND

DOWNLIGHT

SUPPLY DIFFUSER/

RETURN AIR GRILLE

ACOUSTICAL CEILING

GWB/PLASTER CEILING

EXIT SIGN

LAY-IN LIGHT FIXTURE

SPRINKLER HEAD

SMOKE DETECTOR

CURTAIN TRACK

LIMITS OF PROJECT AREA

UNLESS NOTED OTHERWISE

DUCT SMOKE DETECTORS

COVE LIGHT STRIP

EXIST 2-HOUR FIRE BARRIER

EXIST SMOKE PARTITION

EXIST 1-HOUR FIRE BARRIER

EXIST SMOKE BARRIER

9 10 11 12 13 14 15 16 17

A

B

C

CONNECTOR

ENTRY TO NEW

BED TOWER

D

1 111111

A S

R E

Q 'D

7"

TRUE

NORTH

PLAN

NORTH

PROJECT AREA

KEY PLAN

NTS

DEMO RCP GENERAL NOTES

A. REFER TO GENERAL PROJECT NOTES, ARCHITECTURAL NOTES,

SYMBOLS, LEGENDS AND ABBREVIATIONS ON SHEET GI002.

B. REFER TO AND COORDINATE DEMOLITON WORK OF ALL DISIPLINES.

C. REMOVE ALL CEILING SYSTEMS, GWB SOFFITS AND ASSOCIATED

FRAMING IN ALL THE AREAS SHOWN TO BE REMOVED.

D. EXISTING CEILINGS TO REMAIN OUTSIDE OF PROJECT AREA

DEMO RCP KEY NOTES #

REMOVE EXISTING GWB BULKHEAD ABOVE NURSE STATION TO THE

EXTENT REQUIRED TO INSTALL WORK.

REMOVE EXISTING COVE LIGHTING AND PRIVACY CURTAIN TRACK,

TYPICAL ALL LOCATIONS.

REMOVE EXISTING SUSPENDED CEILING SYSTEM, FIXTURES,

EQUIPMENT, DEVICES, POWER COLUMN, PATIENT LIFTS, PRIVACY

CURTAIN TRACKS, IV TRACKS, AND OTHER CEILING MOUNTED ITEMS

AS REQUIRED TO INSTALL WORK. TURN OVER PATIENT LIFTS AND

POWER COLUMNS TO THE GOVERNMENT AND RELOCATE TO A COR

APPROVED LOCATION.

EXISTING SUSPENDED CEILING SYSTEM AND OTHER CEILING

MOUNTED DEVICES IN THE INDICATED AREA TO BE REMOVED AND

STORED FOR REINSTALLATION.

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

DATE:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

BID DOCUMENTS

512 MEANS STREET NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date CheckedFULLY SPRINKLERED

STAMP

STE. 400

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

SJ MC/KB

673-21-145

10-27-2025REVISIONS:

A

B

C

D

E

F

CONSTRUCT NEW BED TOWER

CONNECTOR

13000 BRUCE B DOWNS BLVD

SECOND FLOOR DEMO RCP

AD111

1/8" = 1'-0"AD111

1 SECOND FLOOR DEMO RCP

0' 4' 8' 16' 24'

SCALE: 1/8" = 1' - 0"

CG CG CG CG CGCG CG CG CGCG CGCG CGCG

FEC

FEC

C G

C G

C G

C G

FLOOR PLAN LEGEND

EXISTING CONSTRUCTION TO REMAIN

CONSTRUCTION

LIMITS OF PROJECT AREA

UNLESS NOTED OTHERWISE

LVT-# INDICATES DIRECTION OF SCHEDULED

LUXURY VINYL TILE PLANK FLOORING

INDICATES SIGNAGE LOCATION AND TYPE#

LIMITS OF FLOOR WORK

SMOKE PARTITION

1-HOUR FIRE BARRIER

EXIST 2-HOUR FIRE BARRIER

EXIST SMOKE PARTITION

EXIST 1-HOUR FIRE BARRIER

EXIST SMOKE BARRIER

9 10 11 12 13 14 15 16 17

A

B

C

STORAGE

2D-251A

CORRIDOR

C2-37-1

H.A.C.

2D-252A

STORAGE

2D-251

RESTROOM

2D-249

RT WORK

ROOM

2D-252W

PATIENT

ROOM #14

ISOLATION

2D-252V

PATIENT

ROOM #15

ISOLATION

2D-252U

EQUIPMENT

STORAGE

2D-252T

COMM

2D-252S

CLEAN

LINEN

2D-259

ON CALL

2D-288

RESTROOM

2D-252P

FREEZER

2A-205D

COMPUTER

ROOM

2A-205B

OFFICE

2A-205A

GENERAL

STORAGE

2A-206

GENERAL

STORAGE

2A-207

CORRIDOR

C2-49-1

CONNECTOR

ENTRY TO NEW

BED TOWER

EQUIPMENT

STORAGE

2D-252C

C2-44-2

EQUIPMENT

STORAGE

2D-252B

2D-252C

2D-252B

NURSE

STATION

2D-252

GG6

GG4

ROOF

BELOW

OPEN TO

BELOW

D

OPEN TO

BELOW

4TYP

TYPLVT-1

LV

T-

LV

T-

LV

T-

LV

T-

LV

T-

LV

T-

LV

T-

LVT-1

LVT-1 LVT-1 LVT-1 LVT-1

LVT-1

LVT-1

LVT-3

GI4

GI4

GI4

GI4

ALIGN

ALIGN

GI4

GI4

GI4

LV

T-

LV

T-

TYP

2D -2

A

8'-4"

FV

62'-5"

C

LE

A R

8' -0

4'-4 1/2"

CORRIDOR

C2-44-1

CORRIDOR

C2-44-25

TYP

TYP

GG6GI4

GI4

132'-8"

AE601

AE601

AE601

TYP

TYP

TYP

GI4

GC6

GC6 GC6

GG6

TYP

AE601

4' -0

" M

IN

ROOF

BELOW

INTERIOR

ROOF

BELOW

TRUE

NORTH

PLAN

NORTH

PROJECT AREA

KEY PLAN

NTS

FLOOR PLAN GENERAL NOTES

A. REFER TO GENERAL PROJECT NOTES, ARCHITECTURAL NOTES,

SYMBOLS, LEGENDS AND ABBREVIATIONS ON SHEET GI002.

B. REFER TO AND COORDINATE WITH OTHER DISCIPLINE DRAWINGS FOR

ADDITIONAL REQUIREMENTS.

C. PATCH EXISTING RETAINED CONSTRUCTION ADJACENT TO NEW WORK.

D. REFER TO AE501 FOR PARTITION TYPES AND DETAILS.

E. REFER TO AE601 FOR ROOM FINISH SCHEDULE, BASIS OF DESIGN FINISH

LEGEND, DOOR AND FRAME SCHEDULE AND DETAILS.

F. REFER TO AE601 FOR SIGNAGE SCHEDULE AND TYPES.

G. REFER TO GI002 FOR SIGNAGE MOUNTING HEIGHT

PROVIDE WALL PROTECTION, CORNER GUARDS, HAND RAILS AND CRASH

RAILS AS SCHEDULED. OMIT HAND RAIL WHERE WINDOWS PROHIBIT

INSTALLATION. REFER TO GI002 FOR TYPICAL WALL PROTECTION DIAGRAM

AND ABBREVIATIONS, AE501 FOR DETAILS AND AE601 FOR BASIS OF

DESIGN FINISH LEGEND.

PROVIDE FLOORING AND WALL BASE TO MATCH EXISTING.

INFILL EXISTING OPENING AT REMOVED WINDOW AS INDICATED. MATCH

ADJACENT CONSTRUCTION AND FINISHES.

LINE OF LVT-2 ACCENT FLOORING SEAM TO REFLECT BULKHEAD ABOVE.

SEE AE111 AND AE601 FOR ADDITIONAL INFORMATION.

PROVIDE HOLD OPENS AT EXISTING DOOR TO REMAIN.

PROVIDE SIGNAGE, TYPICAL. REFER TO AE601 FOR SIGNAGE SCHEDULE

AND TYPES. REFER TO SHEET GI002 FOR MOUNTING HEIGHT.

PROVIDE FLUSH MOUNTED FIRE EXTINGUISHER CABINET, TYPICAL ALL

LOCATIONS. SEE DETAIL 3/AE601 AND SHEET GI002 FOR MOUNTING HEIGHT.

PROVIDE DOOR AND FRAME ASSEMBLY, TYPICAL ALL LOCATIONS. REFER

TO AE601 FOR DOOR AND FRAME SCHEDULE AND DETAILS.

FLOOR PLAN KEY NOTES

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

DATE:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

BID DOCUMENTS

512 MEANS STREET NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date CheckedFULLY SPRINKLERED

STAMP

STE. 400

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

SJ MC/KB

673-21-145

10-27-2025REVISIONS:

A

B

C

D

E

F

CONSTRUCT NEW BED TOWER

CONNECTOR

13000 BRUCE B DOWNS BLVD

SECOND FLOOR PLAN

AE101

1/8" = 1'-0"AE101

1 SECOND FLOOR PLAN

0' 4' 8' 16' 24'

SCALE: 1/8" = 1' - 0"

G

C G

C G

C G

RCP LEGEND

SUPPLY DIFFUSER/ RETURN AIR GRILLE

ACOUSTICAL GRID CEILING (2'x2')

EXIT SIGN

LAY-IN LIGHT FIXTURE

SPRINKLER HEAD

DOWN LIGHT FIXTURE

GWB BULKHEAD/ SOFFIT

OCCUPANCY SENSOROS

LIMITS OF PROJECT AREA

UNLESS NOTED OTHERWISE

SMOKE PARTITION

1-HOUR FIRE BARRIER

EXIST 2-HOUR FIRE BARRIER

EXIST SMOKE PARTITION

EXIST 1-HOUR FIRE BARRIER

EXIST SMOKE BARRIER

9 10 11 12 13 14 15 16 17

A

B

C

CONNECTOR

ENTRY TO NEW

BED TOWER

D

CORRIDOR

C2-44-2

EQUIPMENT

STORAGE

2D-252C

EQUIPMENT

STORAGE

2D-252B

2 2

A

LI

G N

A

LI

G N

TY

P

AE111

OS

OSOS

AT-1

9'-0" AFF

AT-1

9'-0" AFF

AT-1

9'-0" AFF

TYP

UNO

BULKHEAD HEIGHT

TO BE 8'-8" AFF,

TYP

E Q

4' -0

E

Q

E Q

4' -0

E

Q

4 5

TYP. TYP.

TYP.

TYP.

AT-2

9'-0" AFF

AT-2

9'-0" AFF

AT-2

9'-0" AFF

AT-2

9'-0" AFF

TYP.

EQ EQ

TRUE

NORTH

PLAN

NORTH

PROJECT AREA

KEY PLAN

NTS

RCP GENERAL NOTES

A. REFER TO GENERAL PROJECT NOTES, ARCHITECTURAL NOTES, SYMBOLS,

LEGENDS AND ABBREVIATIONS ON SHEET GI002.

B. COORDINATE WORK INDICATED ON THIS DRAWING WITH ALL DISCIPLINE'S

DRAWINGS AND DOCUMENTS.

C. PATCH EXISTING RETAINED CONSTRUCTION ADJACENT TO NEW WORK

WITH MATCHING MATERIALS AND FINISHES.

D. PROVIDE AND INSTALL SUSPENDED ACOUSTICAL CEILING SYSTEM AS

INDICATED AND SCHEDULED.

E. REFER TO AE601 FOR ROOM FINISH SCHEDULE AND BASIS OF DESIGN

FINISH LEGEND.

RCP KEY NOTES

REINSTALL EXISTING STORED SUSPENDED ACOUSTICAL CEILING

SYSTEM AND OTHER CEILING MOUNTED DEVICES REMOVED TO INSTALL

ABOVE CEILING WORK. REPAIR ANY DAMAGED WITH MATCHING

MATERIALS.

PROVIDE AND INSTALL SUSPENDED CELING SYSTEM.

PATCH AND REPAIR EXISTING CEILING AT RELOCATED SPRINKLER HEAD

TO MATCH EXISTING ADJACENT FINISHES.

PROVIDE LIGHT FIXTURES, TYPICAL ALL LOCATION. REFER TO OTHER

DISCLIPINE DRAWINGS FOR ADDITIONAL INFORMATION.

PROVIDE DIFFUSERS / AIR GRILLE, TYPICAL ALL LOCATION. REFER TO

OTHER DISCLIPINE DRAWINGS FOR ADDITIONAL INFORMATION.

PROVIDE SPRINKER HEAD, TYPICAL ALL LOCATION. REFER TO OTHER

DISCLIPINE DRAWINGS FOR ADDITIONAL INFORMATION.

PROVIDE OCCUPANCY SENSOR, TYPICAL ALL LOCATION. REFER TO

OTHER DISCLIPINE DRAWINGS FOR ADDITIONAL INFORMATION.

PROVIDE EXIT LIGHT, TYPICAL ALL LOCATION. REFER TO OTHER

DISCLIPINE DRAWINGS FOR ADDITIONAL INFORMATION.

4" 4"

EXIST DECK ABOVE

CONT METAL STUD TRACK

METAL STUD BRACING

@ 48" OC

5/8" GWB ON 4" METAL

STUDS @ 16" OC

ACT CEILING

AS SCHEDULED

SEE RCP

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

DATE:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

BID DOCUMENTS

512 MEANS STREET NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date CheckedFULLY SPRINKLERED

STAMP

STE. 400

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

SJ MC/KB

673-21-145

10-27-2025REVISIONS:

A

B

C

D

E

F

CONSTRUCT NEW BED TOWER

CONNECTOR

13000 BRUCE B DOWNS BLVD

SECOND FLOOR RCP

AE111

1/8" = 1'-0"AE111

1 SECOND FLOOR RCP

0' 4' 8' 16' 24'

SCALE: 1/8" = 1' - 0"

1 1/2" = 1'-0"AE111

2 TYPICAL BULKHEAD DETAIL

1 1/2" = 1'-0"

WALL FRAMING DETAIL

1 1/2" = 1'-0"

HANDRAIL/CRASH RAIL DETAIL

1 1/2" = 1'-0"

WALL PENETRATION DETAIL

1 1/2" = 1'-0"

WALL PENETRATIL DETAIL

1 1/2" = 1'-0"

PENETRATION DETAIL

RATED PARTITION

UL W-L-2038

GWB PER PARTITION TYPE

ONE-PART FIRE-

STOPPING SEALANT

WIRE MESH

ELEC CONDUIT MAX

1-1/4" DIA

RATED PARTITION

MTL STUD TRACK WHERE

SLEEVE EXCEEDS 3" DIA

GWB PER

PARTITION TYPE

STL SLEEVE

ONE-PART FIRESTOPPING

SEALANT

INSULATION

(NOT REQUIRED AT ELEC.

CONDUITS)

CONDUIT (LARGER

THAN 1-1/4" DIA OR PIPE)

ACOUSTICAL SEALANT ALL

AROUND EA SIDE

NON-RATED

PARTITION

ACOUSTICAL SEALANT ALL

AROUND EA SIDE

MTL STUD TRACK WHERE

PIPE EXCEEDS 3" DIA

CONDUIT SPRINKLER PIPE

OR INSUL PIPE - SEE

MEP DWGS

HANDRAIL

(OMIT WHERE WINDOWS

PROHIBIT INSTALLATION)

LAG SCREW FASTENERS

MOUNTING BRACKETS @

32" OC

RETAINER CLIP

CRASH RAIL

FRT WOOD

2x8 BLOCKING

LAG SCREW FASTENERS @

32" OC

WALL BASE

2 ROWS 1-1/2" COLD-ROLLED

CHANNEL BRIDGING IN STUD

PUNCHOUTS - ATTACH TO STUDS

W/ SCREWS THRU 18 GA SHEET

METAL CLIP ANGLES

PROVIDE PUNCHED OPENINGS IN

STUDS FOR INSTALLATION OF

BRIDGING

LINE OF GWB JOINT - ALTERNATE

JOINTS EACH SIDE OF WALL, TYP

DOUBLE METAL TRACK

(2) ROWS 1-1/2" COLD-ROLLED

CHANNEL BRIDGING IN STUDS W/

SCREWS THRU 18 GA SHEET

METAL ANGLES - ATTACH TO MIN

(2) STUDS

PROVIDE DOUBLE STUD AT HINGE

JAMB ONLY WHEN INTERESECTING

PARTITION IS WITHIN 12" OF

DOOR JAMB

STRIKE JAMB

- DOUBLE

STUD W/

1/2" BETWEEN

HINGE JAMB

- TRIPLE

STUD W/1/2"

BETWEEN

STUDS

METAL TRACK

1 1/2"

2' -1

0"

2"

16" MAX 16" MAX

M A

X

A502

A502 A502

A502

A502

1 1/2" = 1'-0"

WALL PENETRATION DETAIL

1 1/2" = 1'-0"

RATED WALL PRIORITY DETAIL

LOWEST PRIORITY

TAPE AND JOINT

COMPOUND, TYP

HIGHEST PRIORITY

HM DOOR FRAME

TAPE AND JOINT

COMPOUND, TYP

LOWEST

PRIORITY

HIGHEST

PRIORIT

Y WALL PRIORITY LEGEND

TWO HOUR FIRE & SMOKE WALL

TWO HOUR FIRE RATED WALL

TWO HOUR SHAFTWALL

ONE HOUR FIRE & SMOKE WALL

ONE HOUR FIRE RATED WALL

NON-RATED WALL

PRIORITY 1 - HIGHEST

PRIORITY 2

PRIORITY 3

PRIORITY 4

PRIORITY 5 - LOWEST

ELEVATION

x

M

IN

G

W B

P

A

TC

H W

/ S C

R E

W S

A T

6" O

C A

R O

U N

D P

E R

IM

E

TE

R

RATED PARTITION

UL W-L-2038

MTL STUD TRACK

MTL STUD TRACK

5/8" GWB

GWB PER

PARTITION TYPE

ELECTRICAL

CONDUIT

ONE-PART

FIRESTOPPING

SEALANT

WIRE MESH

2-PIECE GWB

PATCH

15" x 30" MIN GWB-

PATCH W/ SCREWS @ 6"

OC AROUND PERIMETER

6" M

IN

2" 2" 2"

2"

A502

A502

1 1/2" = 1'-0"

WALL PENETRATION DETAIL

1 1/2" = 1'-0"

WALL OUTLET PARTITION DETAIL

NOTE: REQUIREMENTS SHOWN IN THIS DETAIL ARE TO BE CONSIDERED AS MINIMUM

REQUIREMENTS FOR INSTALLATION OF FIRE DAMPERS. INSTALLATION MUST ALSO CONFORM

TO FIRE DAMPER MANUFACTURER'S "UL" APPROVED INSTALLATION INSTRUCTIONS.

RATED PARTITION - SEE MECH DRAWINGS

ACCESS PANEL

1/4" TO 1/2"

CLEARANCE

MTL STUD TRACK

DUCT

1" MIN OVERLAP

ALL SIDES

FIRE OR SMOKE

DAMPER - SEE

MECH

"S" LOCK DUCT

CONNECTIONS FACTORY-FABRICATED SLEEVE (1)

GAGE HEAVIER THAN APPROPRIATE

SMACNA GAGE FOR CONNECTING

DUCT STEEL

ANGLE ALL AROUND BOTH SIDES

OF WALL - MITER AND WELD ALL

CORNERS

ELECTRICAL BOX

JOINT

ACOUSTICAL SEALANT ALL

AROUND AT SOUND RATED WALLS

NOTES:

1. DRYWALL IS APPLIED VERTICALLY.

2. STUDS ARE 16" OC.

3. JOINTS SHALL RECEIVE JOINT TAPE AND COMPOUND.

4. ALL INSULATION HAS BEEN OMITTED FOR CLARITY.

5. OFFSET BACK-TO-BACK ELECTRICAL BOXES 24"

OC MIN AT FIRE RATED PARTITIONS.

24"

A502

A502

1 1/2" = 1'-0"

FRAMING BLOCKING DETAIL

NOTE: PROVIDE BLOCKING AS SHOWN FOR GRAB BARS, HANDRAILS, CABINETS,

SHELF STANDARDS, TACK BOARDS AND OTHER WALL MOUNTED EQUIPMENT AND

FOR SECURING PLUMBING PIPING AND OTHER ITEMS CONCEALED IN WALL.

MTL STUDS

KERF BLOCKING TO

CLEAR

BACK-BEND ON STUD

FLANGE

SCREW THRU

STUD TO

ANCHOR

BLOCKING

2x8 FR WOOD

BLOCKING OR

METAL BACKER

PLATE

A502

PLAN

4' -0

WALL

PROTECTION

STRUCTURAL DECK

BACKER ROD AND

ACOUSTICAL SEALANT,

BOTH SIDES

CEILING PER FINISH

SCHEDULE

6" MTL

STUDS

GC6

GC

ACOUSTICAL INSULATION

STC 45

PARTITION TYPES

20 GA MTL STUDS @ 16"

OC

5/8" TYPE "X" GWB, BOTH

SIDES (CBB AT TILE

FINISH)

BASE AND FLOOR FINISH

PER SCHEDULE

BACKER ROD AND

ACOUSTICAL SEALANT,

BOTH SIDES

SET RUNNERS ON

SEALANT, TYP

STRUCTURAL DECK

BACKER ROD AND

ACOUSTICAL SEALANT,

BOTH SIDES

CEILING PER FINISH

SCHEDULE

GG

4" MTL

STUDS

GG4

1-HOUR FIRE RATED

UL U495

20 GA MTL STUDS @ 16"

OC

5/8" TYPE "X" GWB, BOTH

SIDES (CBB AT TILE

FINISH)

BASE AND FLOOR FINISH

PER SCHEDULE

BACKER ROD AND

ACOUSTICAL SEALANT,

BOTH SIDES

SET RUNNERS ON

SEALANT, TYP

NTS

SEE FLOOR PLAN FOR REQUIRED

SMOKE PARTITION LOCATIONS

ACOUSTICAL INSULATION

STRUCTURAL DECK

GI

4" MTL

STUDS

GI4

1-HOUR FIRE RATED

UL V497

20 GA MTL STUDS @ 16"

OC

2 LAYERS OF 5/8" TYPE "X"

GWB (CBB AT TILE FINISH)

BASE AND FLOOR FINISH

PER SCHEDULE

BACKER ROD AND

ACOUSTICAL SEALANT,

BOTH SIDES

SET RUNNERS ON

SEALANT, TYP

6" MTL

STUDS

GI6

ACOUSTICAL INSULATION

FIRESTOP SEALANT

DEFLECTION TRACK

4" MTL

STUDS

GG6

STRUCTURAL DECK

ADJUSTABEL

UPPER PANEL

ADJUSTABLE

HYDRAULIC CLOSER

ANGLE MOUNTED TO

GASKET AND ADHERED TO

FORM SEAL WITH FRAME

SOLID ALUMINUM

THRESHOLD STRIP

WITH NEOPRENE

GASKET MATERIAL

SEAL TO THE FLOOR

NOT TO SCALE

TEMPORARY ICRA BARRIER PARTITION

A502

NOT TO SCALE

TEMPORARY ICRA BARRIER ENTRANCE DOOR

A502

STRUCTURAL DECK

ADJUSTABEL

UPPER PANEL

ADJUSTABLE

HYDRAULIC CLOSER

ANGLE MOUNTED TO

GASKET AND ADHERED TO

FORM SEAL WITH FRAME

SELF LATCHING, LOCKING HANDLE

WITH KEYED OUTSIDE AND

THUMBTURN INSIDE WITH

COMBINATION PUSH BUTTON LOCK

GASKETED SWEEP TO PREVENT

DUST AND DEBRIS ESCAPE

SOLID ALUMINUM THRESHOLD

STRIP WITH NEOPRENE GASKET

SEAL TO FLOOR

NOTE:

1. SYSTEM MUST BE 1 HOUR RATED

PER NFPA 241

NOTE:

1. SYSTEM MUST BE 1 HOUR RATED

PER NFPA 241

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

DATE:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

BID DOCUMENTS

512 MEANS STREET NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date CheckedFULLY SPRINKLERED

STAMP

STE. 400

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

SJ MC/KB

673-21-145

10-27-2025REVISIONS:

A

B

C

D

E

F

CONSTRUCT NEW BED TOWER

CONNECTOR

13000 BRUCE B DOWNS BLVD

PARTITION TYPES AND DETAILS

AE501

FINISH LEGEND (BASIS OF DESIGN)

SYMBOL MANUFACTURER SERIES/ PATTERN MODEL NUMBER COLOR DESCRIPTION

ACOUSTICAL CEILING TILE (AT)

AT-1 ROCKFON ALASKA 10200 WHITE 24" X 24" SQUARE TEGULAR WITH CHICAGO METALLIC TEMPRA 4000 GRID

CORNER GUARDS (CG)

CG-1 INPRO

SURFACE MOUNT

CORNER GUARD TBD

STAINLESS

STEEL FULL HEIGHT SURFACE MOUNT INSTALLATION; 3 1/2" WIDTH - 16 GAUGE

RESILIENT WALL BASE (RB)

RB-1 JOHNSONITE

TRADITIONAL VINYL

WALL BASE 29 MOON ROCK 4" HEIGHT

WALL PROTECTION (WP)

WP-1

CONSTRUCTION

SPECIALTIES

ACROVYN SOLID

COLORS 314- .4" THICK OZARK 48" HIGH RWC WAINSCOT

ROOM FINISH SCHEDULE GENERAL NOTES

A. ALL FINISH AND COLOR SELECTIONS AND THEIR LOCATIONS SHALL BE VERIFIED AND APPROVED BY THE COR. ALL PRODUCTS LISTED ARE PROVIDED AS A BASIS OF DESIGN PER

VAMC TAMPA STANDARD FINISH SELECTIONS.

B. DIRECTION OF LVT PLANK FLOORING SHALL BE VERIFIED AND APPROVED BY THE COR; SEAMING DIAGRAM SHOP DRAWING TO BE PROVIDED AS REQUIRED BY THE

SPECIFICATIONS. REFER TO FLOOR PLAN FOR DIRECTION OF LVT PLANK FLOORING.

C. PROVIDE TRANSITION STRIP AT FLOORING FINISH CHANGE.

CRASH RAIL (CR)

CR-1

CONSTRUCTION

SPECIALTIES GROUP

ACROVYN CRASH RAIL SCR-64N

DRIFTEDWOOD

262-SUEDE

HANDRAIL (HR)

HR-1

CONSTRUCTION

SPECIALTIES GROUP

ACROVYN PLATFORM

HANDRAIL

DRIFTEDWOOD

262-SUEDEP-RAA

PAINT (P)

P-1 PPG EGGSHELL 102-2

SILENT

SMOKE

MAIN WALLS

P-2 PPG SEMI-GLOSS 0996-5 STEAMSHIP TRIM AND DOOR FRAMES

LUXURY VINYL TILE (LVT)

LVT-1

MANNINGTON ANCHOR-STRIDE

WINTER

FLEECE

C137 6" X 36" FIELD PATTERN

SURFACE MOUNT; TO BE INSTALLED 2" ABOVE WALL BASE

SURFACE MOUNT; TO BE INSTALLED AT 36" AFF

LVT-2

PATCRAFT SENSE LVT EASEV1 00100 9" X 36" FIELD PATTERN

P-3 PPG FLAT 1025-1

COMMERCIAL

WHITE

CEILINGS

MATCH EXISTING ADJACENT LVT. VERIFY WITH CORLVT-3

RB-2 MATCH EXISTING ADJACENT RB. VERIFY WITH COR

P-4 MATCH EXISTING ADJACENT PAINT. VERIFY WITH COR

WP-2 MATCH EXISTING ADJACENT WP. VERIFY WITH COR

AT-2 MATCH EXISTING ADJACENT ACT. VERIFY WITH COR

A

SEE SCHED

S E

E S

C H

E D

U

LE

DOOR TYPES

NTS

FRAME TYPES

NTS

S E

E S

C H

E D

U

LE

2" SEE SCHED

2"

2"SEE SCHED

S E

E S

C H

E D

U

LE

2' -9

3'

-6

9" 3"

B

RIRE RATED

GLASS

FRAME PER SCHEDULE

DOOR PER SCHEDULE

TRANSITION STRIP AS

APPROPRIATE

FLOOR FINISH PER

SCHEDULE

PARTITION PER TYPE

SEALANT, EACH SIDE

FRAME PER SCHEDULE

DOOR PER SCHEDULE

DOUBLE METAL TRACK

PARTITION PER TYPE

SEALANT, EACH SIDE

FRAME PER SCHEDULE

DOOR PER SCHEDULE

DOUBLE METAL STUD

JAMB ANCHOR

SILL DETAIL

SCALE: 3"=1'-0"

S1

JAMB DETAIL

SCALE: 3"=1'-0"

J1

HEAD DETAIL

SCALE: 3"=1'-0"

H1

ROOM FINISH SCHEDULE REMARKS:

1. PROVIDE WALL PROTECTION, HANDRAIL, CRASH RAIL AND CORNER GUARDS AS INDICATED ON FLOOR PLAN.

REFER TO DRAWING GI002 WALL PROTECTION INTERIOR ELEVATION DIAGRAM.

2. GWB BULKHEAD TO BE 8'-8" AFF, P-3 PAINT. REFER TO DETAIL 3/AE501.

3. REFER TO AE101 FOR DIRECTION OF LVT PLANK FLOORING.

4. MATCH EXISTING ADJACENT LVT. VERIFY WITH COR

ROOM FINISH SCHEDULE GENERAL NOTES:

A. ALL FINISH AND COLOR SELECTIONS AND THEIR LOCATIONS SHALL BE VERIFIED AND APPROVED BY THE COR. ALL PRODUCTS LISTED ARE PROVIDED AS A BASIS OF DESIGN PER

VAMC TAMPA STANDARD FINISH SELECTIONS.

B. DIRECTION OF LVT PLANK FLOORING SHALL BE VERIFIED AND APPROVED BY THE COR; SEAMING DIAGRAM SHOP DRAWING TO BE PROVIDED AS REQUIRED BY THE

SPECIFICATIONS. REFER TO FLOOR PLAN FOR DIRECTION OF LVT PLANK FLOORING.

C. PROVIDE TRANSITION STRIP AT FLOORING FINISH CHANGE.

DOOR AND FRAME SCHEDULE REMARKS:

1. PROVIDE PIV CARD READER FOR ACCESS CONTROL.

2. PAIR OF EQUAL LEAF DOORS.

3. D TYPE OPNG.- INTEGRATED DOOR ASSEMBLY

(SPEC 081710)

NOT TO SCALE

BASIS OF DESIGN: TO MATCH EXISTING HOSPITAL SIGNAGE STANDARD

9" INSIDE FRAME DIMENSION

9"

IN

S

ID

E F

R A

M E

D

IM

E N

S

IO

N

3" 6" 5"

8"

.060" ROOM NUMBER PANEL FIRST SURFACE PAINTED WITH

RAISED NUMBERS AND BRAILLE 3/16" ACRYLIC BACKER (CLEAR)

MAGNET TAPE BACKING FOR MOUNTING.

SIMPLY PREMIER FRAME BEVELED EDGE

STANDARD DEPTH METAL INSIDE.

.060" GLOSSY PETG FACE

FIRST SURFACE PAINTED WITH VINYL MASKED WINDOW

.118" CLEAR PETG WINDOW SPACER

.060" WINDOW BACK

BACK PAINTED WITH MAGNET TAPE FOR MOUNTING

NOT TO SCALE

BASIS OF DESIGN: TO MATCH EXISTING HOSPITAL SIGNAGE STANDARD

WALL DIRECTIONAL - SINGLE INSERT

NEW BMS- DOOR

CONTACTS (2)

NEW CARD READER

CEILING

NEW ELEC. HINGE OR EPT

NEW CLOSER (IF NOT EXIST.)

NEW ELEC. EXIT DEVICE

1. OPENINGS ARE SHOWN FROM INTERIOR SECURE

PROTECTED SIDE. DOTTED LINES INDICATE

DEVICES LOCATED ON THE OPPOSITE UNSECURE

APPROACH SIDE.

2. REFER TO VA PSRDM APPENDIX A1 VA STANDARD

SECURITY DOOR TYPES.

3. NOT ALL SYSTEMS DEVICES SHOWN OCCUR AT

EACH OPENING. REFER TO SYSTEMS DRAWINGS

FOR DEVICES REQUIRED.

D TYPE

OPENING-

(Both Active)

PAIR SWING

EXIT DEVICES

EXIST. FLOOR

FACTORY DRILL DOOR

FOR WIRING TO NEW

ELEC. EXIT DEVICE

PROVIDE DOOR, FRAME, & HARDWARE PER SPEC 08 17 10 INTEGRATED DOOR ASSEMBLIES.

SILL DETAIL

SCALE: 3"=1'-0"

S2

JAMB DETAIL

SCALE: 3"=1'-0"

J2

HEAD DETAIL

SCALE: 3"=1'-0"

H2

PARTITION PER TYPE

SEALANT, EACH SIDE

FRAME PER SCHEDULE

DOOR PER SCHEDULE

DOUBLE METAL TRACK

FRAME PER SCHEDULE

DOOR PER SCHEDULE

TRANSITION STRIP AS

APPROPRIATE

FLOOR FINISH PER

SCHEDULE

PARTITION PER TYPE

SEALANT, EACH SIDE

FRAME PER SCHEDULE

DOOR PER SCHEDULE

DOUBLE METAL STUD

JAMB ANCHOR

EXIST PARTITION

EXIST PARTITION

F.V.

FIELD VERIFY

METAL STUD TRACK

PARTITION TYPE AS SCHEDULED

STAINLESS STEEL,

5/16" FLAT TRIM FULLY RECESSED FIRE

EXTINGUISHER CABINET

BASIS OF DESIGN: LARSON 2409-R1

NOTE:

A. BASIS OF DESIGN: LARSEN 2409-R1, STAINLESS STEEL, 5/16" FLAT TRIM FULLY RECESSED FIRE EXTINGUISHER CABINET

B. SEE FLOOR PLAN ON SHEET 1/AE101 FOR FEC LOCATIONS.

C. REFER TO SHEET GI002 FOR MOUNTING HEIGHT.

PARTITION TYPE AS SCHEDULED

5/16" FLAT TRIM FULLY RECESSED FIRE

EXTINGUISHER CABINET

AT FIRE-RATED WALL, WRAP

5/8", TYPE "X" GWB AROUND

RECESSED SIDES OF F.E.C.

AT FIRE-RATED WALL, WRAP 5/8",

TYPE "X" GWB AROUND BACK OF F.E.C.

ELEVATION DETAIL PLAN DETAIL

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

DATE:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

BID DOCUMENTS

512 MEANS STREET NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date CheckedFULLY SPRINKLERED

STAMP

STE. 400

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

SJ MC/KB

673-21-145

10-27-2025REVISIONS:

A

B

C

D

E

F

CONSTRUCT NEW BED TOWER

CONNECTOR

13000 BRUCE B DOWNS BLVD

SCHEDULES, NOTES AND DETAILS

AE601

ROOM FINISH SCHEDULE

Number ROOM NAME FLOOR BASE

EAST

WALL

NORTH

WALL

SOUTH

WALL

WEST

WALL WAINSCOT CEILING

CLG.

HT. REMARKS

2D-252B EQUIPMENT

STORAGE

LVT-1 RB-1 P-1 P-1 P-1 P-1 -- AT-1 9'-0"

2D-252C EQUIPMENT

STORAGE

LVT-1 RB-1 P-1 P-1 P-1 P-1 -- AT-1 9'-0"

C2-44-1 CORRIDOR LVT-3 RB-2 P-4 P-4 P-4 EXIST WP-2 AT-2 9'-0" 1,4

C2-44-2 CORRIDOR LVT-1/LVT-2 RB-1 P-1 P-1 P-1 P-1 WP-1 AT-1 9'-0" 1,2,3

REVISION 1 4-8-2020

3" = 1'-0"AE601

4 DOOR DETAIL 1

DOOR AND FRAME SCHEDULE

DOOR NO. WIDTH HEIGHT

DOOR

TYPE

DOOR

MATERIAL

FRAME

TYPE

FRAME

MATERIAL

HEAD

DETAIL

JAMB

DETAIL

SILL

DETAIL

FIRE

RATING HARDWARE SET REMARKS

2D-251A 3'-6" 7'-0" A WD 1 HM H2 J2 S2 45 MIN 4F

2D-252B 3'-6" 7'-0" A WD 1 HM H1 J1 S1 45 MIN 4F

2D-252C 7'-0" 7'-0" A HM 1 HM H1 J1 S1 45 MIN 10L 2

C2-44-2 7'-0" 7'-0" A HM 1 HM H1 J1 S1 20 MIN SH-10 1,2,3

SIGNAGE SCHEDULE

SIGN TYPE ROOM NO. ROOM NAME CONTENT MOUNT

1 2D-252B EQUIPMENT STORAGE EQUIPMENT STORAGE WALL MOUNTED

1 2D-252C EQUIPMENT STORAGE EQUIPMENT STORAGE WALL MOUNTED

1 2D-251A STORAGE STORAGE WALL MOUNTED

1 C2-44-1 CORRIDOR -- WALL MOUNTED

2 C2-44-2 CORRIDOR OR SURGERY WALL MOUNTED

2 C2-44-2 CORRIDOR ICU WALL MOUNTED

GENERAL SIGNAGE NOTES:

A. PROVIDE AND INSTALL SIGNAGE IN ACCORDANCE WITH FACILITY GUIDELINES, STANDARDS AND REQUIREMENTS. SIGNAGE TYPE, CONTENT, LOCATION AND QUANTITY TO BE COORDINATED WITH VENDOR, VA STAFF, AND COR FOR ACCEPTANCE AND APPROVAL. SUBMIT A SHOP DRAWING WITH COORDINATION RESULTS FOR REVIEW. ROOM IDENTIFICATION SIGNAGE TYPE IS INCLUDED FOR BIDDING. CONFIRM SIGN TYPE WITH COR.

B. SEE DRAWING GI002 FOR SIGNAGE MOUNTING HEIGHTS.

C. REFER TO 1/AE101 FLOOR PLAN FOR SIGNAGE LOCATIONS.

AE601

1 SIGN TYPE 1

AE601

2 SIGN TYPE 2

1/2" = 1'-0"AE601

6 SECURITY DOOR TYPES

3" = 1'-0"AE601

5 DOOR DETAIL 2

1 1/2" = 1'-0"AE601

3 FIRE EXTINGUISHER CABINET DETAIL

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

DATE:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

BID DOCUMENTS

512 MEANS STREET NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date CheckedFULLY SPRINKLERED

STAMP

STE. 400

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

BS/DH/DK DK

673-21-145

10-27-2025REVISIONS:

A

B

C

D

E

F

CONSTRUCT NEW BED TOWER

CONNECTOR

13000 BRUCE B DOWNS BLVD

FIRE PROTECTION LEGEND, ABBREVIATIONS

AND NOTES

FP001

FIRE PROECTION ABBREVIATIONSFIRE PROTECTION PROJECT NOTES

ABOVE FINISH FLOOR

ELECTRICAL

EXISTING

FINISHED FLOOR

FINISH

FLOOR

NOT TO SCALE

TYPICAL

AFF

ELEC

EXIST

FF

FIN

FLR

NTS

TYP

A. THE CONTRACTOR SHALL BE PREPARED TO…