This is a Polarized Light Microscopy (PLM) Report Summary from Arrowhead Technologies, LLC for asbestos bulk sample analysis of the JAHVA Bed Tower project for GLE Associates. On 1/10/2025, forty-eight bulk material samples were submitted and analyzed using Polarized Light Microscopy/Dispersion Staining (PLM/DS) test methods. The samples included various building materials such as ceiling tiles, drywall, joint compound, fireproofing, floor tiles, caulk, mastic, baseboards, and thermal system insulation.

Critically, none of the 48 samples analyzed contained asbestos. The report notes that the EPA considers a material asbestos-containing only if it contains more than one percent asbestos by Calibrated Visual Area Estimation (CVAE). The samples were analyzed by layers, with specific component asbestos content indicated when relevant. The report was prepared by analyst Ryan Schwegman and laboratory director Monte Hall, with a report date of 1/16/2025, and is associated with Lab Set No. 014280 and AT Job No. 25-14280.

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PLM REPORT SUMMARY

3151 San Bernadino St.

Clearwater, Florida 33759

NVLAP Lab Code 200703-0813-679-0720 / mhall005@tampabay.rr.com

Client : GLE Associates Lab Set No. : 014280

Project : JAHVA Bed Tower 25-14280AT Job No. :

24000-30656Client Project No.: Report Date : 1/16/2025

Identification : Asbestos, Bulk Sample Analysis Sample Date : 1/10/2025

Test Method : Polarized Light Microscopy / Dispersion Staining (PLM/DS) Page 1 of 7App E to Sub E of 40 CFR Part 763 and EPA Method 600/R-93/116

On 1/10/2025, forty-eight (48) bulk material samples were submitted by Justin Zapata for asbestos analysis by PLM/DS.

Copies of Bulk Sample Analysis sheets are attached; additional information may be found therein. The results are summarized below:

Asbestos ContentSample Description / LocationLab Sample No.

None Detected-White Ceiling Tile2x2 White Bevel Fissure Pinhole CT CT-01-A014280-001

None Detected-White Ceiling Tile2x2 White Bevel Fissure Pinhole CT CT-01-B014280-002

None Detected-White Ceiling Tile2x2 White Bevel Fissure Pinhole CT CT-01-C014280-003

None Detected-White Joint CompoundDrywall/Joint Compound DW-01-A014280-004 None Detected-White Drywall Material

None Detected-White Joint CompoundDrywall/Joint Compound DW-01-B014280-005 None Detected-White Drywall Material

None Detected-White Joint CompoundDrywall/Joint Compound DW-01-C014280-006 None Detected-White Drywall Material

None Detected-Gray FireproofingGray Fireproofing FP-01-A014280-007

None Detected-Gray FireproofingGray Fireproofing FP-01-B014280-008

None Detected-Gray FireproofingGray Fireproofing FP-01-C014280-009

None Detected-Gray/Blue FireproofingBlue Fireproofing FP-02-A014280-010

None Detected-Gray/Blue FireproofingBlue Fireproofing FP-02-B014280-011

These samples were analyzed by layers. Specific layer or component asbestos content is indicated when relevant. The EPA considers a material to be asbestos containing only if it contains more than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) -- materials which are friable or may become friable -- be further analyzed by point counting when the results indicate less than ten percent asbestos by CVAE. Arrowhead utilizes CVAE on a routine basis and does not include point counting unless specifically requested.

The results may not be reproduced except in full.

PLM Report Summary - Revision 4 - 08/04/2022- Issuing Authority: Monte Hall, PG mailto:mhall005@tampabay.rr

Clearwater, Florida 33759

NVLAP Lab Code 200703-0813-679-0720 / mhall005@tampabay.rr.com

Client : GLE Associates Lab Set No. : 014280

Project : JAHVA Bed Tower 25-14280AT Job No. :

24000-30656Client Project No.: Report Date : 1/16/2025

Identification : Asbestos, Bulk Sample Analysis Sample Date : 1/10/2025

Test Method : Polarized Light Microscopy / Dispersion Staining (PLM/DS) Page 2 of 7App E to Sub E of 40 CFR Part 763 and EPA Method 600/R-93/116

On 1/10/2025, forty-eight (48) bulk material samples were submitted by Justin Zapata for asbestos analysis by PLM/DS.

Copies of Bulk Sample Analysis sheets are attached; additional information may be found therein. The results are summarized below:

Asbestos ContentSample Description / LocationLab Sample No.

None Detected-Gray/Blue FireproofingBlue Fireproofing FP-02-C014280-012

None Detected-White Floor Tile12x12 White FT/Yellow Mastic FT-01-A014280-013 None Detected-Yellow Mastic

None Detected-White Floor Tile12x12 White FT/Yellow Mastic FT-01-B014280-014 None Detected-Yellow Mastic

None Detected-White Floor Tile12x12 White FT/Yellow Mastic FT-01-C014280-015 None Detected-Yellow Mastic

None Detected-Tan Floor Tile12x12 Tan FT/Brown Mastic FT-02-A014280-016 None Detected-Brown Mastic

None Detected-Tan Floor Tile12x12 Tan FT/Brown Mastic FT-02-B014280-017 None Detected-Brown Mastic

None Detected-Tan Floor Tile12x12 Tan FT/Brown Mastic FT-02-C014280-018 None Detected-Brown Mastic

None Detected-Pink Floor Tile12x12 Pink FT/Brown Mastic FT-03-A014280-019 None Detected-Brown Mastic

These samples were analyzed by layers. Specific layer or component asbestos content is indicated when relevant. The EPA considers a material to be asbestos containing only if it contains more than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) -- materials which are friable or may become friable -- be further analyzed by point counting when the results indicate less than ten percent asbestos by CVAE. Arrowhead utilizes CVAE on a routine basis and does not include point counting unless specifically requested.

The results may not be reproduced except in full.

Clearwater, Florida 33759

NVLAP Lab Code 200703-0813-679-0720 / mhall005@tampabay.rr.com

Client : GLE Associates Lab Set No. : 014280

Project : JAHVA Bed Tower 25-14280AT Job No. :

24000-30656Client Project No.: Report Date : 1/16/2025

Identification : Asbestos, Bulk Sample Analysis Sample Date : 1/10/2025

Test Method : Polarized Light Microscopy / Dispersion Staining (PLM/DS) Page 3 of 7App E to Sub E of 40 CFR Part 763 and EPA Method 600/R-93/116

On 1/10/2025, forty-eight (48) bulk material samples were submitted by Justin Zapata for asbestos analysis by PLM/DS.

Copies of Bulk Sample Analysis sheets are attached; additional information may be found therein. The results are summarized below:

Asbestos ContentSample Description / LocationLab Sample No.

None Detected-Pink Floor Tile12x12 Pink FT/Brown Mastic FT-03-B014280-020 None Detected-Brown Mastic

None Detected-Pink Floor Tile12x12 Pink FT/Brown Mastic FT-03-C014280-021 None Detected-Brown Mastic

None Detected-Teal Floor Tile12x12 Teal FT/Brown Mastic FT-04-A014280-022 None Detected-Brown Mastic

None Detected-Teal Floor Tile12x12 Teal FT/Brown Mastic FT-04-B014280-023 None Detected-Brown Mastic

None Detected-Teal Floor Tile12x12 Teal FT/Brown Mastic FT-04-C014280-024 None Detected-Brown Mastic

None Detected-Black CaulkBlack Caulk M-01-A014280-025

None Detected-Black CaulkBlack Caulk M-01-B014280-026

None Detected-Black CaulkBlack Caulk M-01-C014280-027

None Detected-Gray CaulkGray Caulk M-02-A014280-028

None Detected-Gray CaulkGray Caulk M-02-B014280-029

These samples were analyzed by layers. Specific layer or component asbestos content is indicated when relevant. The EPA considers a material to be asbestos containing only if it contains more than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) -- materials which are friable or may become friable -- be further analyzed by point counting when the results indicate less than ten percent asbestos by CVAE. Arrowhead utilizes CVAE on a routine basis and does not include point counting unless specifically requested.

The results may not be reproduced except in full.

Clearwater, Florida 33759

NVLAP Lab Code 200703-0813-679-0720 / mhall005@tampabay.rr.com

Client : GLE Associates Lab Set No. : 014280

Project : JAHVA Bed Tower 25-14280AT Job No. :

24000-30656Client Project No.: Report Date : 1/16/2025

Identification : Asbestos, Bulk Sample Analysis Sample Date : 1/10/2025

Test Method : Polarized Light Microscopy / Dispersion Staining (PLM/DS) Page 4 of 7App E to Sub E of 40 CFR Part 763 and EPA Method 600/R-93/116

On 1/10/2025, forty-eight (48) bulk material samples were submitted by Justin Zapata for asbestos analysis by PLM/DS.

Copies of Bulk Sample Analysis sheets are attached; additional information may be found therein. The results are summarized below:

Asbestos ContentSample Description / LocationLab Sample No.

None Detected-Gray CaulkGray Caulk M-02-C014280-030

None Detected-Gray Sink MasticGray Sink Undercoating M-03-A014280-031

None Detected-Gray Sink MasticGray Sink Undercoating M-03-B014280-032

None Detected-Gray Sink MasticGray Sink Undercoating M-03-C014280-033

None Detected-Tan MasticTan Duct Mastic MAS-01-A014280-034

None Detected-Tan MasticTan Duct Mastic MAS-01-B014280-035

None Detected-Tan MasticTan Duct Mastic MAS-01-C014280-036

None Detected-White MasticWhite TSI Mastic/Fiberglass TSI-01-A014280-037 None Detected-Yellow Glass Insulation

None Detected-White MasticWhite TSI Mastic/Fiberglass TSI-01-B014280-038 None Detected-Yellow Glass Insulation

None Detected-White MasticWhite TSI Mastic/Fiberglass TSI-01-C014280-039 None Detected-Yellow Glass Insulation

These samples were analyzed by layers. Specific layer or component asbestos content is indicated when relevant. The EPA considers a material to be asbestos containing only if it contains more than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) -- materials which are friable or may become friable -- be further analyzed by point counting when the results indicate less than ten percent asbestos by CVAE. Arrowhead utilizes CVAE on a routine basis and does not include point counting unless specifically requested.

The results may not be reproduced except in full.

Clearwater, Florida 33759

NVLAP Lab Code 200703-0813-679-0720 / mhall005@tampabay.rr.com

Client : GLE Associates Lab Set No. : 014280

Project : JAHVA Bed Tower 25-14280AT Job No. :

24000-30656Client Project No.: Report Date : 1/16/2025

Identification : Asbestos, Bulk Sample Analysis Sample Date : 1/10/2025

Test Method : Polarized Light Microscopy / Dispersion Staining (PLM/DS) Page 5 of 7App E to Sub E of 40 CFR Part 763 and EPA Method 600/R-93/116

On 1/10/2025, forty-eight (48) bulk material samples were submitted by Justin Zapata for asbestos analysis by PLM/DS.

Copies of Bulk Sample Analysis sheets are attached; additional information may be found therein. The results are summarized below:

Asbestos ContentSample Description / LocationLab Sample No.

None Detected-White MasticWhite TSI Mastic/Foamglass TSI-02-A014280-040 None Detected-Black Foam Glass

None Detected-White MasticWhite TSI Mastic/Foamglass TSI-02-B014280-041 None Detected-Black Foam Glass

None Detected-White MasticWhite TSI Mastic/Foamglass TSI-02-C014280-042 None Detected-Black Foam Glass

None Detected-Gray Baseboard6" Gray CB/Tan Mastic VB-01-A014280-043 None Detected-Tan Mastic

None Detected-Gray Baseboard6" Gray CB/Tan Mastic VB-01-B014280-044 None Detected-Tan Mastic

None Detected-Gray Baseboard6" Gray CB/Tan Mastic VB-01-C014280-045 None Detected-Tan Mastic

None Detected-Teal Baseboard6" Teal CB/Tan Mastic VB-02-A014280-046 None Detected-Tan Mastic

None Detected-Teal Baseboard6" Teal CB/Tan Mastic VB-02-B014280-047 None Detected-Tan Mastic

These samples were analyzed by layers. Specific layer or component asbestos content is indicated when relevant. The EPA considers a material to be asbestos containing only if it contains more than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) -- materials which are friable or may become friable -- be further analyzed by point counting when the results indicate less than ten percent asbestos by CVAE. Arrowhead utilizes CVAE on a routine basis and does not include point counting unless specifically requested.

The results may not be reproduced except in full.

Clearwater, Florida 33759

NVLAP Lab Code 200703-0813-679-0720 / mhall005@tampabay.rr.com

Client : GLE Associates Lab Set No. : 014280

Project : JAHVA Bed Tower 25-14280AT Job No. :

24000-30656Client Project No.: Report Date : 1/16/2025

Identification : Asbestos, Bulk Sample Analysis Sample Date : 1/10/2025

Test Method : Polarized Light Microscopy / Dispersion Staining (PLM/DS) Page 6 of 7App E to Sub E of 40 CFR Part 763 and EPA Method 600/R-93/116

On 1/10/2025, forty-eight (48) bulk material samples were submitted by Justin Zapata for asbestos analysis by PLM/DS.

Copies of Bulk Sample Analysis sheets are attached; additional information may be found therein. The results are summarized below:

Asbestos ContentSample Description / LocationLab Sample No.

None Detected-Teal Baseboard6" Teal CB/Tan Mastic VB-02-C014280-048 None Detected-Tan Mastic

These samples were analyzed by layers. Specific layer or component asbestos content is indicated when relevant. The EPA considers a material to be asbestos containing only if it contains more than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) -- materials which are friable or may become friable -- be further analyzed by point counting when the results indicate less than ten percent asbestos by CVAE. Arrowhead utilizes CVAE on a routine basis and does not include point counting unless specifically requested.

The results may not be reproduced except in full.

Clearwater, Florida 33759

NVLAP Lab Code 200703-0813-679-0720 / mhall005@tampabay.rr.com

Client : GLE Associates Lab Set No. : 014280

Project : JAHVA Bed Tower 25-14280AT Job No. :

24000-30656Client Project No.: Report Date : 1/16/2025

Identification : Asbestos, Bulk Sample Analysis Sample Date : 1/10/2025

Test Method : Polarized Light Microscopy / Dispersion Staining (PLM/DS) Page 7 of 7App E to Sub E of 40 CFR Part 763 and EPA Method 600/R-93/116

SCOPE OF THIS REPORT

These samples were obtained as a part of a building survey; this report is only intended to be used as a part of the survey report issued by the surveyor. This report explains the laboratory analysis and results. The surveyor's report explains the sampling protocol used, when the samples were obtained, the location(s) of the samples, where the materials were observed in the building, quantities of materials observed, condition of the materials and the extent of his/her survey. Sample locations and material descriptions are given by the surveyor on the chain of custody but included here (possibly abbreviated)only as a convenience for the reader.

This report may not be reproduced without written permission of Arrowhead Technologies, LLC and must be reproduced in full.

STATEMENT OF LABORATORY ACCREDITATION

The samples were analyzed in general accordance with the procedures outlined in the Method for the Determinationof Asbestos in Bulk Building Materials, EPA/600/R-93/116,and the Interim Method for the Determinationof Asbestos in Bulk Insulation Samples, EPA 600/M4-82-020. The results of each bulk sample relate only to the material tested as received and the results shall not be used to claim product endorsement by NVLAP or any agency of the U.S. Government.

Floor tile and other resinously bound materials, when analyzed by the EPA method, may yield false negative results because of limitations in separating closely bound fibers and in detecting fibers of small length and diameter. When a definitive result is required, Arrowhead recommendsutilizing alternative methods of identification, including Transmission Electron Microscopy.

Specific questions concerning bulk sample results shall be directed to the Laboratory Director.

Analyst : Ryan Schwegman

Monte Hall, P.G.Laboratory Director :

Florida Registration No. 1658

Approved Signatory :