Drawings_985 Passenger Elevator_2-21-22.pdf
PDF 24 MB Posted
- Solicitation number
- 47PF0022R0056
About this file
This notice is a solicitation for a passenger elevator modernization contract. The General Services Administration Public Buildings Service Region 5 is seeking proposals to renovate three existing passenger elevators in the Federal Garage located at 985 Michigan Avenue in Detroit, Michigan. The modernization is intended to bring the elevators into compliance with ASME A17.1 national standards as well as new International Building Code, National Fire Protection Association, and National Electrical Code requirements. The estimated value of the contract is between $1,000,000 to $5,000,000 and the period of performance for on-site work is 300 calendar days from notice to proceed. This procurement is set aside for small businesses with a NAICS code of 238290 and size standard of $16.5 million. Offerors must attend a pre-proposal conference on June 10, 2022 and register by May 31, 2022. The award will be made based on technical evaluation factors and total price.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MECHANICAL ABBREVIATION LIST
ABBREVIATION DESCRIPTION
COMPRESSED AIR
COMPRESSED AIR (SPECIFIC PSIG)
AUTOMATIC AIR VENT
AIR COOLED CONDENSER
AIR COOLED CONDENSER UNIT
ACCESS DOOR
AREA DRAIN
AIR EXTRACTOR
ABOVE FINISHED FLOOR
AIR HANDLING UNIT
ALTERNATE
AMPERE
AIR PRESSURE DROP
ARGON
AMERICAN SOCIETY OF HEATING, REFRIGERATION
AND AIR-CONDITIONING ENGINEERS
AUTOMATIC SPRINKLER RISER
AIR TRANSFER DUCT
AUXILIARY
ACID VENT
ACID VENT THROUGH ROOF
ACID WASTE
BUILDING AUTOMATION SYSTEM
BLOWER COIL UNIT
BACK DRAFT DAMPER
BELOW FINISHED FLOOR
BACKFLOW PREVENTER
BRAKE HORSEPOWER
BOTTOM OF DUCT
BOTTOM OF PIPE
BRITISH THERMAL UNIT
BRITISH THERMAL UNIT PER HOUR
BEVERAGE CONDUIT
BACKWATER VALVE
COMMON
CAPACITY
CONSTANT AIR VOLUME
CATCH BASIN
COOLING COIL
COLD DECK
CONDENSATE DRAIN
CONTRACTOR FURNISHED, CONTRACTOR INSTALLED
CUBIC FEET PER HOUR
CUBIC FEET PER MINUTE
CHILLER
CHILLED WATER
CHILLED WATER RETURN
CHILLED WATER SUPPLY
COOLING
CONDENSATE
CONDENSATE (SPECIFIC PSIG)
CLEAN OUT
CARBON DIOXIDE
CONTINUATION OR CONTINUED
CONTRACTOR
CONVECTOR
COEFFICIENT OF PERFORMANCE
CIRCULATING PUMP
CONDENSATE RETURN UNIT
CLINICAL SERVICE SINK
COOLING TOWER
CABINET UNIT HEATER
DOMESTIC COLD WATER
DOMESTIC COLD WATER - FILTERED
CONDENSER WATER RETURN
CONDENSER WATER SUPPLY
DRIP AND TRAP
DISCHARGE AIR
DISCHARGE AIR TEMPERATURE
DRY BULB
DIRECT DIGITAL CONTROL
DEGREE
DRY FIRE STAND PIPE
DRAINAGE FIXTURE UNITS
DIAMETER
DAMPER
DAY/NIGHT
DOWN
DOWNSPOUT NOZZLE
DUCT SILENCER
DRAIN TILE
DRAIN TILE CONNECTION
DOMESTIC WATER HEATER
DRAWING
EXISTING
EXHAUST GRILLE OR REGISTER
EACH
EXHAUST AIR
ENTERING AIR TEMPERATURE
EXPANSION COMPENSATOR
ELECTRIC CABINET UNIT HEATER
ENTERING DRY BULB
ENERGY EFFICIENCY RATIO
EMERGENCY EYE WASH / SHOWER
EMERGENCY EYE WASH
EXHAUST FAN
EFFICIENCY
ELECTRIC HEATING COIL
EXPANSION JOINT
ELEVATION
ELECTRICAL
ENERGY MANAGEMENT SYSTEM
ENERGY RECOVERY LOOP
ENERGY RECOVERY LOOP RETURN
ENERGY RECOVERY LOOP SUPPLY
ENERGY RECOVERY UNIT
EMERGENCY SHOWER
EXTERNAL STATIC PRESSURE
ELECTRIC UNIT HEATER
ENTERING WET BULB
ELECTRIC WATER COOLER
ENTERING WATER TEMPERATURE
EXHAUST
FIRE PROTECTION
DEGREES FAHRENHEIT
FACE AND BYPASS
FLOAT AND THERMOSTATIC
FACE AREA
FAN COIL UNIT
ABBREVIATION DESCRIPTION
MECHANICAL SYMBOL LIST
NOTE: SOME SYMBOLS AND ABBREVIATIONS
SHOWN MAY NOT APPLY TO THIS PROJECT.
PIPING SYMBOLS
MECHANICAL DRAWING INDEX
FLOOR DRAIN
FUNNEL FLOOR DRAIN
FIRE HYDRANT
FIRE HOSE CABINET
FIRE HOSE RACK
FIRE HOSE VALVE
FULL LOAD AMPS
FLOOR
FLOW METER
FLOW MEASURING STATION
FEET PER MINUTE
FIRE PUMP
FAN POWERED (AIR) TERMINAL UNIT
FLOOR SINK
FOOD SERVICE EQUIPMENT CONTRACTOR
FEET
FINNED TUBE RADIATION
FACE VELOCITY
NATURAL GAS
GAUGE
GALLON
GRAVITY RELIEF HOOD
GALLONS PER HOUR
GALLONS PER MINUTE
GREASE SANITARY WASTE
HYDROGEN
HOSE BIBB
HEATING COIL
HOT DECK
HIGH EFFICIENCY PARTICULATE ARRESTANCE
HIGH LIMIT
HAND/OFF/AUTO
HEAT PUMP
HORSEPOWER
HIGH PRESSURE DOMESTIC COLD WATER
HIGH PRESSURE DOMESTIC HOT WATER
HIGH PRESSURE DOMESTIC HOT WATER RETURN
HEAT PUMP LOOP
HEAT PUMP LOOP RETURN
HEAT PUMP LOOP SUPPLY
HOUR
HEATING
HEATING VENTILATING
HEATING, VENTILATING, AIR CONDITIONING
HOT WATER HEATING
HOT WATER HEATING RETURN
HOT WATER HEATING SUPPLY
DOMESTIC HOT WATER
DOMESTIC HOT WATER (SPECIFIC TEMP °F)
DOMESTIC HOT WATER RETURN
HEAT EXCHANGER
HERTZ
INDOOR AIR QUALITY
INSIDE DIAMETER
INVERT ELEVATION
INTAKE HOOD
INCHES
INFRARED HEATER
INDIRECT WASTE
JANITOR'S CLOSET
JOCKEY PUMP
THOUSAND AMP
KILOWATT
KILOWATT-HOUR
LEAVING AIR TEMPERATURE
LABORATORY
LAVATORY
POUNDS
LEAVING DRY BULB
LOW LIMIT
LOW PRESSURE CONDENSATE
LOW PRESSURE STEAM
LOCKED ROTOR AMPS
LEAVING WET BULB
LEAVING WATER TEMPERATURE
MIXED AIR
MIXED AIR TEMPERATURE
MAKE-UP AIR UNIT
MAXIMUM
THOUSAND BRITISH THERMAL UNITS PER HOUR
MEDICAL COMPRESSED AIR
MINIMUM CIRCUIT AMPACITY
MOTOR CONTROL CENTER
MECHANICAL
MEZZANINE
MANUFACTURER
MANHOLE
1/1000th INCH
MINIMUM
MISCELLANEOUS
MILLION BRITISH THERMAL UNITS PER HOUR
MAXIMUM OVERCURRENT PROTECTION
MOTOR STARTER
MOUNTED
MOTOR
MANUAL AIR VENT
MEDICAL VACUUM
NITROGEN
NITROUS OXIDE
NOISE CRITERIA
NORMALLY CLOSED
NORMALLY CLOSED TIMED CLOSED
NORMALLY CLOSED TIMED OPEN
NATIONAL FIRE PROTECTION AGENCY
NORMALLY OPEN TIMED CLOSED
NORMALLY OPEN TIMED OPEN
NOT IN CONTRACT
NORMALLY OPEN
NOMINAL
NON POTABLE COLD WATER
ABBREVIATION DESCRIPTION
OXYGEN
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
OUTLET BOX
OPPOSED BLADE DAMPER
ON CENTER/CENTER TO CENTER
OUTSIDE DIAMETER
OPEN ENDED DUCT
OWNER FURNISHED, CONTRACTOR INSTALLED
OWNER FURNISHED, OWNER INSTALLED
OVERLOAD
OVERFLOW RAIN CONDUCTOR
OVERFLOW ROOF DRAIN
OUTSIDE SCREW AND YOKE
OUTLET VELOCITY
OPERATOR WORKSTATION
PACKAGED AIR CONDITIONING UNIT
PARALLEL BLADE DAMPER
PUMPED CONDENSATE
PROCESS COOLING WATER
PROCESS COOLING WATER RETURN
PROCESS COOLING WATER SUPPLY
PRESSURE DROP (FEET OF WATER)
PERIMETER HEAT
PERIMETER HEAT RETURN
PERIMETER HEAT SUPPLY
PANEL
PARTS PER MILLION
PRESSURE
PRESSURE REDUCING VALVE
PUMPED SANITARY
POUNDS PER SQUARE INCH
POUNDS PER SQUARE INCH - ABSOLUTE
POUNDS PER SQUARE INCH - GAUGE
PUMPED STORM
PURIFIED WATER
PURIFIED WATER RETURN
PURIFIED WATER SUPPLY
RELOCATED
RETURN GRILLE OR REGISTER
RETURN AIR
RETURN AIR TEMPERATURE
RAIN CONDUCTOR
RADIANT CEILING PANEL
ROOF DRAIN
REQUIRED
ROOF EXHAUST FAN
RETURN FAN
RELATIVE HUMIDITY
REFRIGERANT LIQUID
RELIEF AIR
REVOLUTIONS PER MINUTE
REDUCED PRESSURE BACKFLOW
DETECTION ASSY
REDUCED PRESSURE BACKFLOW
ZONE ASSY
REFRIGERANT SUCTION
ROOFTOP UNIT
SUPPLY AIR DIFFUSER OR GRILLE
SOUND ATTENUATOR
SUPPLY AIR
SANITARY WASTE
SUPPLY AIR TEMPERATURE
SHORT CIRCUIT CURRENT RATING
SECTION
SUPPLY FAN
SHOWER
SINK
SNOW MELT RETURN
SNOW MELT SUPPLY
SPRINKLER PIPING
STATIC PRESSURE
SPECIFICATION
SPRINKLER
SQUARE FOOT/SQUARE FEET
START/STOP
SERVICE SINK
STORM
STANDARD
STACK
STEAM
STEAM (SPECIFIC PSIG)
SUMMER/WINTER
SWITCH
TRANSFER GRILLE
TEMPERATURE CONTROL
TEMPERING COIL
TEMPERATURE CONTROL PANEL
TRENCH DRAIN
TEMPERATURE
TEMPORARY
TERMINAL HEATING
TOTAL HEAT ABSORBED
TERMINAL HEATING RETURN
TOTAL HEAT REJECTED
TERMINAL HEATING SUPPLY
TEPID WATER
TOTAL STATIC PRESSURE
(AIR) TERMINAL UNIT
TURNING VANES
TEMPERED WATER
TYPICAL
UNIT HEATER
UNDERWRITER'S LABORATORY
UNLESS OTHERWISE NOTED
URINAL
UNIT VENTILATOR
VALVE
VENT
VACUUM
VARIABLE AIR VOLUME
VACUUM BREAKER
VOLUME DAMPER (MANUALLY ADJUSTABLE)
VOLUME
VARIABLE FREQUENCY CONTROLLER
VENT THROUGH ROOF
VENTURI TERMINAL UNIT
VERTICAL UNIT VENTILATOR
WASTE
WASTE AND VENT
WASTE ANESTHETIC GAS DISPOSAL
WET BULB
WATER CLOSET
WATER COLUMN
WATER GAUGE
WALL HYDRANT
WASHING MACHINE SUPPLY AND DRAIN BOX
WATER PRESSURE DROP
WEIGHT
TRANSFORMER
ZONE VALVE BOX
TEMPERATURE CONTROL - PARTIAL SYMBOLS LIST
SYMBOL DESCRIPTION
CO2 CARBON DIOXIDE SENSOR
CO
DPT
FM
CARBON MONOXIDE SENSOR
DIFFERENTIAL PRESSURE TRANSMITTER
FLOW METER
GUARD FOR STAT OR SENSOR
HUMIDISTAT OR HUMIDITY SENSOR
(AS DEFINED ON TC DRAWINGS)
SYMBOL DESCRIPTION
OCCUPANCY SENSOR
PT PRESSURE TRANSMITTER
STATIC PRESSURE SENSOR OR PROBE
VALVE - 2 WAY CONTROL VALVE
VALVE - 3 WAY CONTROL VALVE
THERMOSTAT OR TEMPERATURE SENSOR
(AS DEFINED ON TC DRAWINGS)
T
OS
SP
H
NOTE: LIST OF ADDITIONAL SYMBOLS & ABBREVIATIONS ASSOCIATED WITH
TEMPERATURE CONTROLS ARE IDENTIFIED ON TC DRAWINGS.
SYMBOL DESCRIPTION
AIR VENT - AUTOMATIC
AIR VENT - MANUAL
BACKFLOW PREVENTER
CATCH BASIN
CIRCULATING PUMP
CLEAN OUT - IN FLOOR
CLEAN OUT - FLANGE
DIRECTION OF FLOW
DIRECTION OF PITCH - DOWN
FINNED TUBE RADIATION
FIRE PROTECTION - SIAMESE CONNECTION - FREE STANDING
FIRE PROTECTION - SIAMESE CONNECTION - WALL MOUNTED
FIRE PROTECTION - SPRINKLER HEAD, CONCEALED
FIRE PROTECTION - SPRINKLER HEAD, PENDANT
FIRE PROTECTION - SPRINKLER HEAD, UPRIGHT
FIRE PROTECTION - SPRINKLER HEAD, SIDEWALL
FLOOR DRAIN
FLOOR DRAIN - ELEVATION
FLOOR DRAIN - FUNNEL
FLOOR DRAIN - FUNNEL, ELEVATION
FLOW MEASURING DEVICE (FOR TEST AND BALANCING)
FLOW SWITCH
HOSE BIBB
MANHOLE
OPEN SITE DRAIN
PIPE - ANCHOR
PIPE - CAP OR PLUG
PIPE - ELBOW DOWN
PIPE - ELBOW UP
PIPE - EXPANSION JOINT OR COMPENSATOR
PIPE - FLANGE
PIPE - HOSE AND BRAID FLEXIBLE CONNECTION
PIPE - GUIDE
PIPE - TEE DOWN
PIPE - TEE UP
PIPE - UNION
PRESSURE AND TEMPERATURE TEST PLUG
PRESSURE GAUGE AND COCK
REDUCER - CONCENTRIC
REDUCER - ECCENTRIC
ROOF/OVERFLOW DRAIN
STEAM TRAP - FLOAT AND THERMOSTATIC
STRAINER
STRAINER WITH VALVE AND BLOW-OFF
THERMOMETER
TRAP
VALVE - ANGLE
VALVE - BALL
VALVE - BALANCE (i.e. BALANCE VALVE TO 0.5 GPM)
VALVE - BUTTERFLY
VALVE - COMBINATION BALANCE & FLOW MEASURING
VALVE - CHECK
VALVE - SPRING CHECK
VALVE - GAS (MANUAL)
VALVE - GLOBE
VALVE - ISOLATION
VALVE - NEEDLE
VALVE - OS&Y
VALVE - PLUG
VALVE - PRESSURE REGULATING
VALVE - PRESSURE REDUCING
VALVE - PRESSURE RELIEF
VALVE - PRESSURE & TEMPERATURE RELIEF
VENT THROUGH ROOF
WALL HYDRANT
DUCTWORK SYMBOLS
SYMBOL DESCRIPTION
AIR TERMINAL UNIT
AIR TERMINAL UNIT WITH HEATING COIL
VENTURI AIR TERMINAL UNIT
VENTURI AIR TERMINAL UNIT WITH HEATING COIL
DAMPER - HORIZONTAL FIRE (EXISTING, NEW)
DAMPER - HORIZONTAL FIRE / SMOKE (EXISTING, NEW)
DAMPER - SMOKE (EXISTING, NEW)
DAMPER - VERTICAL FIRE (EXISTING, NEW)
DAMPER - VERTICAL FIRE / SMOKE (EXISTING, NEW)
DAMPER - BACK DRAFT
DAMPER - VOLUME (MANUALLY ADJUSTABLE)
DIFFUSER - BLANK OFF
DIFFUSER - LINEAR SLOT
DIFFUSER - SQUARE OR RECTANGULAR
DUCT CROSS SECTION - SUPPLY
DUCT CROSS SECTION - RETURN
DUCT CROSS SECTION - EXHAUST
DUCT - FLEXIBLE CONNECTION
DUCT - FLEXIBLE DUCT
DUCT TAKE-OFF - ROUND CONICAL
DUCT TAKE-OFF - RECTANGULAR WITH SHOE TAP
ELBOW - RECTANGULAR WITH TURNING VANES
ELBOW - RECTANGULAR/ ROUND SMOOTH RADIUS
ELBOW DOWN - RECTANGULAR
ELBOW DOWN - ROUND
ELBOW UP - RECTANGULAR
ELBOW UP - ROUND
FAN - AXIAL
FAN - CENTRIFUGAL (ELEVATION)
HEATING COIL
INCLINED DROP IN DIRECTION OF AIRFLOW
INCLINED RISE IN DIRECTION OF AIRFLOW
INTAKE OR RELIEF HOOD
REGISTER - RETURN OR EXHAUST
REGISTER - RETURN WITH BOOT
REGISTER - TRANSFER GRILLE
ROOF EXHAUST FAN
TRANSITION - CONCENTRIC
TRANSITION - ECCENTRIC
UNIT HEATER - HORIZONTAL THROW
UNIT HEATER - VERTICAL THROW
DOUBLE LINE DUCTWORK SYMBOLS
SYMBOL DESCRIPTION
DUCT TAKE-OFF - RECTANGULAR WITH SHOE TAP
DUCT TAKE-OFF - ROUND CONICAL
ELBOW - RECTANGULAR WITH TURNING VANES
ELBOW - RECTANGULAR SHORT RADIUS WITH
SPLITTER VANES
ELBOW - ROUND
ELBOW - RECTANGULAR SMOOTH RADIUS
ELBOW DOWN - RECTANGULAR
ELBOW DOWN - ROUND
ELBOW UP - RECTANGULAR
ELBOW UP - ROUND
HEATING COIL
INCLINED DROP IN DIRECTION OF AIRFLOW
INCLINED RISE IN DIRECTION OF AIRFLOW
TRANSITION - CONCENTRIC
TRANSITION -ECCENTRIC
D
R
AV
MV
BFP
CO
CO
FS
HB
MH
P/T
VTR
WH
TU-101
TU-101
VTU-101
VTU-101
BDD
D
R
CONSTRUCTION KEY NOTE (NUMBER) OR
DEMOLITION KEY NOTE (LETTER)
SECTION OR PLAN NUMBER
SHEET WHERE SECTION IS DRAWN
M5.1
EQUIPMENT DESIGNATION,
(i.e. EXHAUST FAN NUMBER 1)
EF
M5.1
AREA OF ENLARGEMENT
PLAN NUMBER
SHEET WHERE ENLARGED PLAN IS DRAWN
M5.1
SECTION OR ENLARGED PLAN
SCALE: 1/8" = 1' - 0"
SECTION OR PLAN NUMBER
SHEET WHERE SECTION IS CUT OR
ENLARGED PLAN IS REFERENCED
MATCHLINE
HEAVY LINE WEIGHT INDICATES NEW WORK
LIGHT LINE WEIGHT INDICATES EXISTING
EQUIPMENT OR REFERENCED INFORMATION
GRAY LINE INDICATES BACKGROUND INFORMATION
DASHED LINES INDICATE PIPING
ROUTED BELOW SLAB OR GRADE
HATCH MARKS INDICATE EQUIPMENT OR MATERIALS
TO BE DISCONNECTED AND REMOVED.
POINT OF NEW CONNECTION SYMBOL
EXISTING SYSTEM COMPONENT TO REMAIN
NEW SYSTEM COMPONENT
PIPING RISER DESIGNATION,
(i.e. HOT WATER RISER NUMBER 1)
HW-1
22x10 18x14ø
DUCT SIZE NOTATION
ALL SIZES IN INCHES
8ø
OVAL DUCT
RECTANGULAR DUCT
SHEET M1.0
SHEET M1.1
0.5
0.5 (i.e. BALANCE VALVE TO 0.5 GPM)
DAMPER - MOTORIZEDM
SHEET NO. SHEET TITLE
PIPE - RUBBER FLEXIBLE CONNECTION
FLOW METER
FM
STANDARD METHODS OF NOTATION
SUPPLY DIFFUSER WITH SCHEDULE TAG "1",
10" DIAMETER NECK SIZE
350 CFM TYPICAL FOR 4
S-1 10ø 350-4
RETURN REGISTER WITH SCHEDULE TAG "1",
22"x 22" NECK SIZE
640 CFM TYPICAL FOR 2
EXHAUST REGISTER E DESIGNATION SIMILAR.
R-1 22x22 640-2
AIR TERMINAL UNIT WITH HEATING COIL NO. 101
WITH SERVICE CLEARANCE SHOWN
TU-101
VTU-101
VENTURI AIR TERMINAL WITH HEATING COIL NO. 101
WITH SERVICE CLEARANCE SHOWN
PIPE DIAMETER NOTATION
ALL SIZES IN INCHES
PLUMBING FIXTURE UNIT IDENTIFICATION TAG
WATER CLOSET TYPE "1"
TYPICAL FOR 2
(2)WC-1
A A(___#)
AAV
ACC
ACCU
AD
AD
AE
AFF
AHU
ALT
AMP
APD
AR
ASHRAE
ASR
ATD
AUX
AV
AVTR
AW
BAS
BCU
BDD
BFF
BFP
BHP
BOD
BOP
BTU
BTUH
BVC
BWV
C
CAP
CAV
CB
CC
CD
CD
CFCI
CFH
CFM
CH
CHW
CHWR
CHWS
CLG
CNDS
CNDS (__#)
CO
CO2
CONT
CONTR
CONV
COP
CP
CRU
CSS
CT
CUH
CW
CWF
CWR
CWS
D&T
DA
DAT
DB
DDC
DEG
DFSP
DFU
DIA
DMPR
D/N
DN
DNZ
DS
DT
DTC
DWH
DWG
(E) E
EA
EA
EAT
EC
ECUH
EDB
EER
EES
EEW
EF
EFF
EHC
EJ
EL
ELEC
EMS
ERL
ERLR
ERLS
ERU
ESH
ESP
EUH
EWB
EWC
EWT
EXH
F °F F&B F&T
FA
FCU
FD
FFD
FH
FHC
FHR
FHV
FLA
FLR
FM
FMS
FPM
FP
FPTU
FS
FSEC
FT
FTR
FV
G
GA
GAL
GRH
GPH
GPM
GSAN
H
HB
HC
HD
HEPA
HL
HOA
HP
HP
HPCW
HPHW
HPHWR
HPL
HPLR
HPLS
HR
HTG
HV
HVAC
HWH
HWHR
HWHS
HW
HW(__)
HWR
HX
HZ
IAQ
ID
IE
IH
IN
IR
IW
JC
JP
KA
KW
KWH
LAT
LAB
LAV
LBS
LDB
LL
LPC
LPS
LRA
LWB
LWT
MA
MAT
MAU
MAX
MBH
MCA
MCA
MCC
MECH
MEZZ
MFR
MH
MIL
MIN
MISC
MMBH
MOP
M/S
MTD
MTR
MV
MVAC
N N2O
NC
NC
NCTC
NCTO
NFPA
NOTC
NOTO
NIC
NO
NOM
NPCW
O
OA
OAT
OB
OBD
OC
OD
OED
OFCI
OFOI
OL
ORC
ORD
OS&Y
OV
OWS
PACU
PBD
PC
PCW
PCWR
PCWS
PD
PH
PHR
PHS
PNL
PPM
PRESS
PRV
PSAN
PSI
PSIA
PSIG
PST
PW
PWR
PWS
(R) R
RA
RAT
RC
RCP
RD
REQD
REF
RF
RH
RL
RLFA
RPM
RPDA
RPZA
RS
RTU
S
SA
SA
S, SAN
SAT
SCCR
SECT
SF
SH
SK
SMR
SMS
SP
SP
SPEC
SPKLR
SQFT
S/S
SS
ST
STD
STK
STM
STM(__#)
S/W
SW
T
TC
TC
TCP
TD
TEMP
TEMP
TH
THA
THR
THR
THS
TPD
TSP
TU
TV
TW
TYP
UH
UL
UON
UR
UV
V V
VAC
VAV
VB
VD
VOL
VFC
VTR
VTU
VUV
W W&V
WAGD
WB
WC
WC
WG
WH
WMSD
WPD
WT
XFMR
ZVB
SYMBOL DESCRIPTION
ABBREVIATION DESCRIPTION
COMPRESSED AIR
COMPRESSED AIR (SPECIFIC PSIG)
AUTOMATIC AIR VENT
AIR COOLED CONDENSER
AIR COOLED CONDENSER UNIT
ACCESS DOOR
AREA DRAIN
AIR EXTRACTOR
ABOVE FINISHED FLOOR
AIR HANDLING UNIT
ALTERNATE
AMPERE
AIR PRESSURE DROP
ARGON
AMERICAN SOCIETY OF HEATING, REFRIGERATION
AND AIR-CONDITIONING ENGINEERS
AUTOMATIC SPRINKLER RISER
AIR TRANSFER DUCT
AUXILIARY
ACID VENT
ACID VENT THROUGH ROOF
ACID WASTE
BUILDING AUTOMATION SYSTEM
BLOWER COIL UNIT
BACK DRAFT DAMPER
BELOW FINISHED FLOOR
BACKFLOW PREVENTER
BRAKE HORSEPOWER
BOTTOM OF DUCT
BOTTOM OF PIPE
BRITISH THERMAL UNIT
BRITISH THERMAL UNIT PER HOUR
BEVERAGE CONDUIT
BACKWATER VALVE
COMMON
CAPACITY
CONSTANT AIR VOLUME
CATCH BASIN
COOLING COIL
COLD DECK
CONDENSATE DRAIN
CONTRACTOR FURNISHED, CONTRACTOR INSTALLED
CUBIC FEET PER HOUR
CUBIC FEET PER MINUTE
CHILLER
CHILLED WATER
CHILLED WATER RETURN
CHILLED WATER SUPPLY
COOLING
CONDENSATE
CONDENSATE (SPECIFIC PSIG)
CLEAN OUT
CARBON DIOXIDE
CONTINUATION OR CONTINUED
CONTRACTOR
CONVECTOR
COEFFICIENT OF PERFORMANCE
CIRCULATING PUMP
CONDENSATE RETURN UNIT
CLINICAL SERVICE SINK
COOLING TOWER
CABINET UNIT HEATER
DOMESTIC COLD WATER
DOMESTIC COLD WATER - FILTERED
CONDENSER WATER RETURN
CONDENSER WATER SUPPLY
DRIP AND TRAP
DISCHARGE AIR
DISCHARGE AIR TEMPERATURE
DRY BULB
DIRECT DIGITAL CONTROL
DEGREE
DRY FIRE STAND PIPE
DRAINAGE FIXTURE UNITS
DIAMETER
DAMPER
DAY/NIGHT
DOWN
DOWNSPOUT NOZZLE
DUCT SILENCER
DRAIN TILE
DRAIN TILE CONNECTION
DOMESTIC WATER HEATER
DRAWING
EXISTING
EXHAUST GRILLE OR REGISTER
EACH
EXHAUST AIR
ENTERING AIR TEMPERATURE
EXPANSION COMPENSATOR
ELECTRIC CABINET UNIT HEATER
ENTERING DRY BULB
ENERGY EFFICIENCY RATIO
EMERGENCY EYE WASH / SHOWER
EMERGENCY EYE WASH
EXHAUST FAN
EFFICIENCY
ELECTRIC HEATING COIL
EXPANSION JOINT
ELEVATION
ELECTRICAL
ENERGY MANAGEMENT SYSTEM
ENERGY RECOVERY LOOP
ENERGY RECOVERY LOOP RETURN
ENERGY RECOVERY LOOP SUPPLY
ENERGY RECOVERY UNIT
EMERGENCY SHOWER
EXTERNAL STATIC PRESSURE
ELECTRIC UNIT HEATER
ENTERING WET BULB
ELECTRIC WATER COOLER
ENTERING WATER TEMPERATURE
EXHAUST
FIRE PROTECTION
DEGREES FAHRENHEIT
FACE AND BYPASS
FLOAT AND THERMOSTATIC
FACE AREA
FAN COIL UNIT
ABBREVIATION DESCRIPTION
FLOOR DRAIN
FUNNEL FLOOR DRAIN
FIRE HYDRANT
FIRE HOSE CABINET
FIRE HOSE RACK
FIRE HOSE VALVE
FULL LOAD AMPS
FLOOR
FLOW METER
FLOW MEASURING STATION
FEET PER MINUTE
FIRE PUMP
FAN POWERED (AIR) TERMINAL UNIT
FLOOR SINK
FOOD SERVICE EQUIPMENT CONTRACTOR
FEET
FINNED TUBE RADIATION
FACE VELOCITY
NATURAL GAS
GAUGE
GALLON
GRAVITY RELIEF HOOD
GALLONS PER HOUR
GALLONS PER MINUTE
GREASE SANITARY WASTE
HYDROGEN
HOSE BIBB
HEATING COIL
HOT DECK
HIGH EFFICIENCY PARTICULATE ARRESTANCE
HIGH LIMIT
HAND/OFF/AUTO
HEAT PUMP
HORSEPOWER
HIGH PRESSURE DOMESTIC COLD WATER
HIGH PRESSURE DOMESTIC HOT WATER
HIGH PRESSURE DOMESTIC HOT WATER RETURN
HEAT PUMP LOOP
HEAT PUMP LOOP RETURN
HEAT PUMP LOOP SUPPLY
HOUR
HEATING
HEATING VENTILATING
HEATING, VENTILATING, AIR CONDITIONING
HOT WATER HEATING
HOT WATER HEATING RETURN
HOT WATER HEATING SUPPLY
DOMESTIC HOT WATER
DOMESTIC HOT WATER (SPECIFIC TEMP °F)
DOMESTIC HOT WATER RETURN
HEAT EXCHANGER
HERTZ
INDOOR AIR QUALITY
INSIDE DIAMETER
INVERT ELEVATION
INTAKE HOOD
INCHES
INFRARED HEATER
INDIRECT WASTE
JANITOR'S CLOSET
JOCKEY PUMP
THOUSAND AMP
KILOWATT
KILOWATT-HOUR
LEAVING AIR TEMPERATURE
LABORATORY
LAVATORY
POUNDS
LEAVING DRY BULB
LOW LIMIT
LOW PRESSURE CONDENSATE
LOW PRESSURE STEAM
LOCKED ROTOR AMPS
LEAVING WET BULB
LEAVING WATER TEMPERATURE
MIXED AIR
MIXED AIR TEMPERATURE
MAKE-UP AIR UNIT
MAXIMUM
THOUSAND BRITISH THERMAL UNITS PER HOUR
MEDICAL COMPRESSED AIR
MINIMUM CIRCUIT AMPACITY
MOTOR CONTROL CENTER
MECHANICAL
MEZZANINE
MANUFACTURER
MANHOLE
1/1000th INCH
MINIMUM
MISCELLANEOUS
MILLION BRITISH THERMAL UNITS PER HOUR
MAXIMUM OVERCURRENT PROTECTION
MOTOR STARTER
MOUNTED
MOTOR
MANUAL AIR VENT
MEDICAL VACUUM
NITROGEN
NITROUS OXIDE
NOISE CRITERIA
NORMALLY CLOSED
NORMALLY CLOSED TIMED CLOSED
NORMALLY CLOSED TIMED OPEN
NATIONAL FIRE PROTECTION AGENCY
NORMALLY OPEN TIMED CLOSED
NORMALLY OPEN TIMED OPEN
NOT IN CONTRACT
NORMALLY OPEN
NOMINAL
NON POTABLE COLD WATER
ABBREVIATION DESCRIPTION
OXYGEN
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
OUTLET BOX
OPPOSED BLADE DAMPER
ON CENTER/CENTER TO CENTER
OUTSIDE DIAMETER
OPEN ENDED DUCT
OWNER FURNISHED, CONTRACTOR INSTALLED
OWNER FURNISHED, OWNER INSTALLED
OVERLOAD
OVERFLOW RAIN CONDUCTOR
OVERFLOW ROOF DRAIN
OUTSIDE SCREW AND YOKE
OUTLET VELOCITY
OPERATOR WORKSTATION
PACKAGED AIR CONDITIONING UNIT
PARALLEL BLADE DAMPER
PUMPED CONDENSATE
PROCESS COOLING WATER
PROCESS COOLING WATER RETURN
PROCESS COOLING WATER SUPPLY
PRESSURE DROP (FEET OF WATER)
PERIMETER HEAT
PERIMETER HEAT RETURN
PERIMETER HEAT SUPPLY
PANEL
PARTS PER MILLION
PRESSURE
PRESSURE REDUCING VALVE
PUMPED SANITARY
POUNDS PER SQUARE INCH
POUNDS PER SQUARE INCH - ABSOLUTE
POUNDS PER SQUARE INCH - GAUGE
PUMPED STORM
PURIFIED WATER
PURIFIED WATER RETURN
PURIFIED WATER SUPPLY
RELOCATED
RETURN GRILLE OR REGISTER
RETURN AIR
RETURN AIR TEMPERATURE
RAIN CONDUCTOR
RADIANT CEILING PANEL
ROOF DRAIN
REQUIRED
ROOF EXHAUST FAN
RETURN FAN
RELATIVE HUMIDITY
REFRIGERANT LIQUID
RELIEF AIR
REVOLUTIONS PER MINUTE
REDUCED PRESSURE BACKFLOW
DETECTION ASSY
REDUCED PRESSURE BACKFLOW
ZONE ASSY
REFRIGERANT SUCTION
ROOFTOP UNIT
SUPPLY AIR DIFFUSER OR GRILLE
SOUND ATTENUATOR
SUPPLY AIR
SANITARY WASTE
SUPPLY AIR TEMPERATURE
SHORT CIRCUIT CURRENT RATING
SECTION
SUPPLY FAN
SHOWER
SINK
SNOW MELT RETURN
SNOW MELT SUPPLY
SPRINKLER PIPING
STATIC PRESSURE
SPECIFICATION
SPRINKLER
SQUARE FOOT/SQUARE FEET
START/STOP
SERVICE SINK
STORM
STANDARD
STACK
STEAM
STEAM (SPECIFIC PSIG)
SUMMER/WINTER
SWITCH
TRANSFER GRILLE
TEMPERATURE CONTROL
TEMPERING COIL
TEMPERATURE CONTROL PANEL
TRENCH DRAIN
TEMPERATURE
TEMPORARY
TERMINAL HEATING
TOTAL HEAT ABSORBED
TERMINAL HEATING RETURN
TOTAL HEAT REJECTED
TERMINAL HEATING SUPPLY
TEPID WATER
TOTAL STATIC PRESSURE
(AIR) TERMINAL UNIT
TURNING VANES
TEMPERED WATER
TYPICAL
UNIT HEATER
UNDERWRITER'S LABORATORY
UNLESS OTHERWISE NOTED
URINAL
UNIT VENTILATOR
VALVE
VENT
VACUUM
VARIABLE AIR VOLUME
VACUUM BREAKER
VOLUME DAMPER (MANUALLY ADJUSTABLE)
VOLUME
VARIABLE FREQUENCY CONTROLLER
VENT THROUGH ROOF
VENTURI TERMINAL UNIT
VERTICAL UNIT VENTILATOR
WASTE
WASTE AND VENT
WASTE ANESTHETIC GAS DISPOSAL
WET BULB
WATER CLOSET
WATER COLUMN
WATER GAUGE
WALL HYDRANT
WASHING MACHINE SUPPLY AND DRAIN BOX
WATER PRESSURE DROP
WEIGHT
TRANSFORMER
ZONE VALVE BOX
SYMBOL DESCRIPTION
CARBON DIOXIDE SENSOR
CARBON MONOXIDE SENSOR
DIFFERENTIAL PRESSURE TRANSMITTER
FLOW METER
GUARD FOR STAT OR SENSOR
HUMIDISTAT OR HUMIDITY SENSOR
(AS DEFINED ON TC DRAWINGS)
SYMBOL DESCRIPTION
OCCUPANCY SENSOR
PRESSURE TRANSMITTER
STATIC PRESSURE SENSOR OR PROBE
VALVE - 2 WAY CONTROL VALVE
VALVE - 3 WAY CONTROL VALVE
THERMOSTAT OR TEMPERATURE SENSOR
(AS DEFINED ON TC DRAWINGS)
NOTE: LIST OF ADDITIONAL SYMBOLS & ABBREVIATIONS ASSOCIATED WITH
TEMPERATURE CONTROLS ARE IDENTIFIED ON TC DRAWINGS.
SYMBOL DESCRIPTION
AIR VENT - AUTOMATIC
AIR VENT - MANUAL
BACKFLOW PREVENTER
CATCH BASIN
CIRCULATING PUMP
CLEAN OUT - IN FLOOR
CLEAN OUT - FLANGE
DIRECTION OF FLOW
DIRECTION OF PITCH - DOWN
FINNED TUBE RADIATION
FIRE PROTECTION - SIAMESE CONNECTION - FREE STANDING
FIRE PROTECTION - SIAMESE CONNECTION - WALL MOUNTED
FIRE PROTECTION - SPRINKLER HEAD, CONCEALED
FIRE PROTECTION - SPRINKLER HEAD, PENDANT
FIRE PROTECTION - SPRINKLER HEAD, UPRIGHT
FIRE PROTECTION - SPRINKLER HEAD, SIDEWALL
FLOOR DRAIN
FLOOR DRAIN - ELEVATION
FLOOR DRAIN - FUNNEL
FLOOR DRAIN - FUNNEL, ELEVATION
FLOW MEASURING DEVICE (FOR TEST AND BALANCING)
FLOW SWITCH
HOSE BIBB
MANHOLE
OPEN SITE DRAIN
PIPE - ANCHOR
PIPE - CAP OR PLUG
PIPE - ELBOW DOWN
PIPE - ELBOW UP
PIPE - EXPANSION JOINT OR COMPENSATOR
PIPE - FLANGE
PIPE - HOSE AND BRAID FLEXIBLE CONNECTION
PIPE - GUIDE
PIPE - TEE DOWN
PIPE - TEE UP
PIPE - UNION
PRESSURE AND TEMPERATURE TEST PLUG
PRESSURE GAUGE AND COCK
REDUCER - CONCENTRIC
REDUCER - ECCENTRIC
ROOF/OVERFLOW DRAIN
STEAM TRAP - FLOAT AND THERMOSTATIC
STRAINER
STRAINER WITH VALVE AND BLOW-OFF
THERMOMETER
TRAP
VALVE - ANGLE
VALVE - BALL
VALVE - BALANCE (i.e. BALANCE VALVE TO 0.5 GPM)
VALVE - BUTTERFLY
VALVE - COMBINATION BALANCE & FLOW MEASURING
VALVE - CHECK
VALVE - SPRING CHECK
VALVE - GAS (MANUAL)
VALVE - GLOBE
VALVE - ISOLATION
VALVE - NEEDLE
VALVE - OS&Y
VALVE - PLUG
VALVE - PRESSURE REGULATING
VALVE - PRESSURE REDUCING
VALVE - PRESSURE RELIEF
VALVE - PRESSURE & TEMPERATURE RELIEF
VENT THROUGH ROOF
WALL HYDRANT
SYMBOL DESCRIPTION
AIR TERMINAL UNIT
AIR TERMINAL UNIT WITH HEATING COIL
VENTURI AIR TERMINAL UNIT
VENTURI AIR TERMINAL UNIT WITH HEATING COIL
DAMPER - HORIZONTAL FIRE (EXISTING, NEW)
DAMPER - HORIZONTAL FIRE / SMOKE (EXISTING, NEW)
DAMPER - SMOKE (EXISTING, NEW)
DAMPER - VERTICAL FIRE (EXISTING, NEW)
DAMPER - VERTICAL FIRE / SMOKE (EXISTING, NEW)
DAMPER - BACK DRAFT
DAMPER - VOLUME (MANUALLY ADJUSTABLE)
DIFFUSER - BLANK OFF
DIFFUSER - LINEAR SLOT
DIFFUSER - SQUARE OR RECTANGULAR
DUCT CROSS SECTION - SUPPLY
DUCT CROSS SECTION - RETURN
DUCT CROSS SECTION - EXHAUST
DUCT - FLEXIBLE CONNECTION
DUCT - FLEXIBLE DUCT
DUCT TAKE-OFF - ROUND CONICAL
DUCT TAKE-OFF - RECTANGULAR WITH SHOE TAP
ELBOW - RECTANGULAR WITH TURNING VANES
ELBOW - RECTANGULAR/ ROUND SMOOTH RADIUS
ELBOW DOWN - RECTANGULAR
ELBOW DOWN - ROUND
ELBOW UP - RECTANGULAR
ELBOW UP - ROUND
FAN - AXIAL
FAN - CENTRIFUGAL (ELEVATION)
HEATING COIL
INCLINED DROP IN DIRECTION OF AIRFLOW
INCLINED RISE IN DIRECTION OF AIRFLOW
INTAKE OR RELIEF HOOD
REGISTER - RETURN OR EXHAUST
REGISTER - RETURN WITH BOOT
REGISTER - TRANSFER GRILLE
ROOF EXHAUST FAN
TRANSITION - CONCENTRIC
TRANSITION - ECCENTRIC
UNIT HEATER - HORIZONTAL THROW
UNIT HEATER - VERTICAL THROW
SYMBOL DESCRIPTION
DUCT TAKE-OFF - RECTANGULAR WITH SHOE TAP
DUCT TAKE-OFF - ROUND CONICAL
ELBOW - RECTANGULAR WITH TURNING VANES
ELBOW - RECTANGULAR SHORT RADIUS WITH
SPLITTER VANES
ELBOW - ROUND
ELBOW - RECTANGULAR SMOOTH RADIUS
ELBOW DOWN - RECTANGULAR
ELBOW DOWN - ROUND
ELBOW UP - RECTANGULAR
ELBOW UP - ROUND
HEATING COIL
INCLINED DROP IN DIRECTION OF AIRFLOW
INCLINED RISE IN DIRECTION OF AIRFLOW
TRANSITION - CONCENTRIC
TRANSITION -ECCENTRIC
CONSTRUCTION KEY NOTE (NUMBER) OR
DEMOLITION KEY NOTE (LETTER)
SECTION OR PLAN NUMBER
SHEET WHERE SECTION IS DRAWN
EQUIPMENT DESIGNATION,
(i.e. EXHAUST FAN NUMBER 1)
AREA OF ENLARGEMENT
PLAN NUMBER
SHEET WHERE ENLARGED PLAN IS DRAWN
SCALE: 1/8" = 1' - 0"
SECTION OR PLAN NUMBER
SHEET WHERE SECTION IS CUT OR
ENLARGED PLAN IS REFERENCED
MATCHLINE
HEAVY LINE WEIGHT INDICATES NEW WORK
LIGHT LINE WEIGHT INDICATES EXISTING
EQUIPMENT OR REFERENCED INFORMATION
GRAY LINE INDICATES BACKGROUND INFORMATION
DASHED LINES INDICATE PIPING
ROUTED BELOW SLAB OR GRADE
HATCH MARKS INDICATE EQUIPMENT OR MATERIALS
TO BE DISCONNECTED AND REMOVED.
POINT OF NEW CONNECTION SYMBOL
EXISTING SYSTEM COMPONENT TO REMAIN
NEW SYSTEM COMPONENT
PIPING RISER DESIGNATION,
(i.e. HOT WATER RISER NUMBER 1)
HW-1
22x10 18x14ø
DUCT SIZE NOTATION
ALL SIZES IN INCHES
8ø
OVAL DUCT
RECTANGULAR DUCT
0.5
0.5 (i.e. BALANCE VALVE TO 0.5 GPM)
DAMPER - MOTORIZED
SHEET NO. SHEET TITLE
PIPE - RUBBER FLEXIBLE CONNECTION
FLOW METER
SUPPLY DIFFUSER WITH SCHEDULE TAG "1",
10" DIAMETER NECK SIZE
350 CFM TYPICAL FOR 4
S-1 10ø 350-4
RETURN REGISTER WITH SCHEDULE TAG "1",
22"x 22" NECK SIZE
640 CFM TYPICAL FOR 2
EXHAUST REGISTER E DESIGNATION SIMILAR.
R-1 22x22 640-2
AIR TERMINAL UNIT WITH HEATING COIL NO. 101
WITH SERVICE CLEARANCE SHOWN
VENTURI AIR TERMINAL WITH HEATING COIL NO. 101
WITH SERVICE CLEARANCE SHOWN
PIPE DIAMETER NOTATION
ALL SIZES IN INCHES
PLUMBING FIXTURE UNIT IDENTIFICATION TAG
WATER CLOSET TYPE "1"
TYPICAL FOR 2
(2)WC-1
A A(___#)
AAV
ACC
ACCU
AD
AD
AE
AFF
AHU
ALT
AMP
APD
AR
ASHRAE
ASR
ATD
AUX
AV
AVTR
AW
BAS
BCU
BDD
BFF
BFP
BHP
BOD
BOP
BTU
BTUH
BVC
BWV
C
CAP
CAV
CB
CC
CD
CD
CFCI
CFH
CFM
CH
CHW
CHWR
CHWS
CLG
CNDS
CNDS (__#)
CO
CO2
CONT
CONTR
CONV
COP
CP
CRU
CSS
CT
CUH
CW
CWF
CWR
CWS
D&T
DA
DAT
DB
DDC
DEG
DFSP
DFU
DIA
DMPR
D/N
DN
DNZ
DS
DT
DTC
DWH
DWG
(E) E
EA
EA
EAT
EC
ECUH
EDB
EER
EES
EEW
EF
EFF
EHC
EJ
EL
ELEC
EMS
ERL
ERLR
ERLS
ERU
ESH
ESP
EUH
EWB
EWC
EWT
EXH
F °F F&B F&T
FA
FCU
FD
FFD
FH
FHC
FHR
FHV
FLA
FLR
FM
FMS
FPM
FP
FPTU
FS
FSEC
FT
FTR
FV
G
GA
GAL
GRH
GPH
GPM
GSAN
H
HB
HC
HD
HEPA
HL
HOA
HP
HP
HPCW
HPHW
HPHWR
HPL
HPLR
HPLS
HR
HTG
HV
HVAC
HWH
HWHR
HWHS
HW
HW(__)
HWR
HX
HZ
IAQ
ID
IE
IH
IN
IR
IW
JC
JP
KA
KW
KWH
LAT
LAB
LAV
LBS
LDB
LL
LPC
LPS
LRA
LWB
LWT
MA
MAT
MAU
MAX
MBH
MCA
MCA
MCC
MECH
MEZZ
MFR
MH
MIL
MIN
MISC
MMBH
MOP
M/S
MTD
MTR
MV
MVAC
N N2O
NC
NC
NCTC
NCTO
NFPA
NOTC
NOTO
NIC
NO
NOM
NPCW
O
OA
OAT
OB
OBD
OC
OD
OED
OFCI
OFOI
OL
ORC
ORD
OS&Y
OV
OWS
PACU
PBD
PC
PCW
PCWR
PCWS
PD
PH
PHR
PHS
PNL
PPM
PRESS
PRV
PSAN
PSI
PSIA
PSIG
PST
PW
PWR
PWS
(R) R
RA
RAT
RC
RCP
RD
REQD
REF
RF
RH
RL
RLFA
RPM
RPDA
RPZA
RS
RTU
S
SA
SA
S, SAN
SAT
SCCR
SECT
SF
SH
SK
SMR
SMS
SP
SP
SPEC
SPKLR
SQFT
S/S
SS
ST
STD
STK
STM
STM(__#)
S/W
SW
T
TC
TC
TCP
TD
TEMP
TEMP
TH
THA
THR
THR
THS
TPD
TSP
TU
TV
TW
TYP
UH
UL
UON
UR
UV
V V
VAC
VAV
VB
VD
VOL
VFC
VTR
VTU
VUV
W W&V
WAGD
WB
WC
WC
WG
WH
WMSD
WPD
WT
XFMR
ZVB
SYMBOL DESCRIPTION
Peter Basso Associates Inc
CONSULTING ENGINEERS
5145 Livernois, Suite 100
Troy, Michigan 48098-3276
Tel: 248-879-5666
Fax: 248-879-0007 www.PeterBassoAssociates.com
PBA Project No.: 2020-0353
0 8' 16' 1/8"=1'-0"
ST
AM
P
OR
S
EA
L
OW
NE
R
ID
EN
TIF
IC
AT
IO
N
BU
ILD
IN
G
PR
OJ
EC
T
SH
EE
T
General Services Administration Public Buildings Service
Great Lakes
BUILDING NAME
ADDRESS
CITY, STATE, ZIP
BUILDING NO.
PROJECT TITLE
GSA PROJECT NO.
SUBMISSION STAGE
SUBMISSION DATE
DRAWN BY
CHECKED BY
FLOOR NO.
DISCIPLINE
PLAN TYPE
SHEET NUMBER
AND FILENAME
KE
Y
PL
AN
GR
AP
HI
C
SC
AL
E
985 Michigan Avenue
Detroit, Michigan 48225
MI0801DF
985 Passenger Elevator
Modernization
RMI12521
BID DOCUMENTS
02/21/2022
Design and Construction, Project Delivery Division John C. Kluczynski Federal Building 230 South Dearborn St.
Chicago, IL 60604
CO
NT
RA
CT
DE
SI
GN
ER
ID
EN
TI
FIC
AT
IO
N
CONST. CONTRACT NO.
DELIVER ORDER NO.
A/E CONTRACT NO.
CO
NS
UL
TA
NT
ID
EN
TIF
IC
AT
IO
N
RE
VI
SI
ON
B
LO
CK
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY - DO NOT REMOVE THIS NOTICE - PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDEDSENSITIVE BUT UNCLASSIFIED
SENSITIVE BUT UNCLASSIFIED
MECHANICAL
985 Federal Building Parking Garage
816 E 4th ST.
Royal Oak, MI 48067 248.542.7866/www.ghfaa.com
A S S O C I A T E S A R C H I T E C T S
INDEX AND ABBREVIATIONS
47PF0021F0046
GP-05-P13-SVD-0030
RLT
DC
M-001
N/A
C R
E V
I T L
O C
A L
F
IL
E S
\M I0
M
E P
L
-R
M a b ro w n
.r v t
/1
/2
:1
:5 A
M
M-001 MECHANICAL STANDARDS AND DRAWING INDEX
M-100 UNDERGROUND AND LOWER LEVEL MECHANICAL PLANS
M-102 ELEVATOR MACHINE ROOM MECHANICAL PLANS
M-601 MECHANICAL DETAILS
M-701 MECHANICAL SCHEDULES
M-702 MECHANICAL SCHEDULES
M-801 TEMPERATURE CONTROL STANDARDS AND GENERAL NOTES
M-802 TEMPERATURE CONTROLS
MARK DATE DESCRIPTION
D
D
M N P
4.7
5.7
S P
2" S
P
2" S
T
S P
2" S
P 4"
D F
S P
2" D
F S
P
2" S
P
2" S
T
S P
DFSP
(E) 4"
DFSP UP
(E) 4"
DFSP UP
D F
S P
4" ST
10" ST
(E)3" ST UP
(E)CO
10" ST
2" V
2" SP
(E)2" V DN
(E)FD
(E)FIRE PROTECTION
SERVING ROOM
CORRIDOR
CLL08
ELEVATOR PIT
ROOM
CLL08-1
METER ROOM
LL12
STAIR NO. 5
S-5
(E)FD
(E)CO
TD-1
(E)CO
STORAGE ROOM
LL11
CORRIDOR
CLL07
STORAGE
LL13
GSA MDF ROOM
LL14
M N P
4.7
5.7
2" V
4" S
(E)CO
4 SAN UP
TO (E)FD
(E)2 V UP
2" V
(E)2 V
CONNECTED OFF
TOP OF 4 SAN
(E)V
UNDERGROUND
TO RISER
4" S
4 SAN UP
TO (E)FD
(E)CO
4" S
4 SAN UP
TO TD-1
Peter Basso Associates Inc
CONSULTING ENGINEERS
5145 Livernois, Suite 100
Troy, Michigan 48098-3276
Tel: 248-879-5666
Fax: 248-879-0007 www.PeterBassoAssociates.com
PBA Project No.: 2020-0353
0 8' 16' 1/8"=1'-0"
ST
AM
P
OR
S
EA
L
OW
NE
R
ID
EN
TIF
IC
AT
IO
N
BU
ILD
IN
G
PR
OJ
EC
T
SH
EE
T
General Services Administration Public Buildings Service
Great Lakes
BUILDING NAME
ADDRESS
CITY, STATE, ZIP
BUILDING NO.
PROJECT TITLE
GSA PROJECT NO.
SUBMISSION STAGE
SUBMISSION DATE
DRAWN BY
CHECKED BY
FLOOR NO.
DISCIPLINE
PLAN TYPE
SHEET NUMBER
AND FILENAME
KE
Y
PL
AN
GR
AP
HI
C
SC
AL
E
985 Michigan Avenue
Detroit, Michigan 48225
MI0801DF
985 Passenger Elevator
Modernization
RMI12521
BID DOCUMENTS
02/21/2022
Design and Construction, Project Delivery Division John C. Kluczynski Federal Building 230 South Dearborn St.
Chicago, IL 60604
CO
NT
RA
CT
DE
SI
GN
ER
ID
EN
TI
FIC
AT
IO
N
CONST. CONTRACT NO.
DELIVER ORDER NO.
A/E CONTRACT NO.
CO
NS
UL
TA
NT
ID
EN
TIF
IC
AT
IO
N
RE
VI
SI
ON
B
LO
CK
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY - DO NOT REMOVE THIS NOTICE - PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDEDSENSITIVE BUT UNCLASSIFIED
SENSITIVE BUT UNCLASSIFIED
MECHANICAL
985 Federal Building Parking Garage
816 E 4th ST.
Royal Oak, MI 48067 248.542.7866/www.ghfaa.com
A S S O C I A T E S A R C H I T E C T S
FLOOR PLAN
47PF0021F0046
GP-05-P13-SVD-0030
RLT
DC
M-100
LOWER
C R
E V
I T L
O C
A L
F
IL
E S
\M I0
M
E P
L
-R
M a b ro w n
.r v t
/1
/2
:1
:0 A
M
SCALE: 1/4" = 1'-0"
LOWER LEVEL PLUMBING NEW WORK PLAN
PLUMBING GENERAL NOTES:
1 THESE DRAWINGS ARE DIAGRAMMATIC, AND REPRESENT THE GENERAL INTENT AND ARRANGEMENT OF
SYSTEMS. THEY ARE NOT TO BE CONSIDERED FABRICATION/COORDINATION/SHOP DRAWINGS.
COORDINATION WITH OTHER TRADES IS REQUIRED. PROVIDE THE ADDITIONAL FITTINGS AND OFFSETS THAT WILL BE REQUIRED TO COMPLETE EACH SYSTEM AND TO AVOID INTERFERENCES WITH ALL OTHER SYSTEMS INCLUDING THE STRUCTURE, SHEET METAL, OTHER PIPING SYSTEMS, ELECTRICAL CONDUITS, BUS DUCTS, CABLE TRAY, LIGHT FIXTURES, ETC. AND/OR OTHER SPACE CONSTRAINTS.
2 INSTALL SYSTEMS SUCH THAT REQUIRED CLEARANCE AND SERVICE ACCESS SPACE IS PROVIDED AROUND
ALL MECHANICAL AND ELECTRICAL EQUIPMENT, AND AROUND ANY COMPONENTS WHICH REQUIRE
SERVICE ACCESS.
3 PIPING SHALL NOT BE INSTALLED ABOVE ELECTRICAL TRANSFORMERS, SWITCHBOARDS, PANELBOARDS
OR MOTOR CONTROL CENTERS.
4 COORDINATE AND PROVIDE ACCESS DOORS WITHIN INACCESSIBLE CEILING, SHAFT, AND CHASE AREAS FOR ALL COMPONENTS WHICH REQUIRE SERVICE ACCESS. REFER TO ARCHITECTURAL DRAWINGS FOR
CEILING TYPES.
5 PROVIDE SUPPLEMENTARY STEEL AS REQUIRED FOR THE PROPER SUPPORT OF ALL SYSTEMS.
6 REFER TO ARCHITECTURAL PLANS FOR DIMENSIONED LOCATIONS OF PLUMBING FIXTURES.
7 MINIMUM UNDERGROUND PIPE SIZE SHALL BE 3".
8 PLUMBING VENT PIPING THROUGH ROOF SHALL BE LOCATED A MINIMUM OF 10'-0" FROM ANY FRESH AIR
INTAKE LOCATION AND A MINIMUM OF 18" CLEAR FROM THE INSIDE FACE OF PARAPET.
9 PROVIDE CODE REQUIRED CLEARANCE FOR ALL CLEANOUTS INSTALLED IN SANITARY WASTE AND VENT
PIPING.
SCALE: 1/4" = 1'-0"
UNDERGROUND PLUMBING NEW WORK PLAN
D
D
M N P
4.7
5.7 x S
A x S
A
36x12 RA
UP TO RTU
(AC-PE)
28x14 RA
UP TO RTU
(AC-PE)
30x6 SA
GRILLE
(TYP. 4)
(E)15 KW ELECTRIC
UNIT HEATER (EUH-B)
ELEVATOR
MACHINE ROOM
P1201-1
1" D
F S
P
BALANCE EXISTING
DIFFUSERS TO 550
CFM (TYP. 4)
(E)TSTAT
MOUNTED ON
UNIT
NEW TSTAT
AC-PE
NEW DDC
ROOM TEMP
SENSOR
M N P
4.7
5.7
36x12 RA
UP TO RTU
(EX AC-PE)
28x14 RA
UP TO RTU
(EX AC-PE)
30x6 SA
GRILLE
(TYP. 4)
x S
A x S
A
(E)15 KW ELECTRIC
UNIT HEATER (EUH-B)
PE
(E)AC
A
1" D
F S
P(ON ROOF)
(E)TSTAT
EXISTING
AC-PE
(E)TSTAT
MOUNTED ON UNIT
A
B
ELEVATOR
MACHINE ROOM
P1201-1
C
M N P
4.7
5.7
(E)ROOF DRAIN
(E)ROOF HATCH
(E)STAIRWELL
PRESSURIZATION
HOOD AND FAN
PE
AC
ROUTE 3/4
CONDENSATE FROM
RTU TO (E) ROOF DRAIN
3/ 4"
C D
PIPE SUPPORTS
(TYP.)
Peter Basso Associates Inc
CONSULTING ENGINEERS
5145 Livernois, Suite 100
Troy, Michigan 48098-3276
Tel: 248-879-5666
Fax: 248-879-0007 www.PeterBassoAssociates.com
PBA Project No.: 2020-0353
0 8' 16' 1/8"=1'-0"
ST
AM
P
OR
S
EA
L
OW
NE
R
ID
EN
TIF
IC
AT
IO
N
BU
ILD
IN
G
PR
OJ
EC
T
SH
EE
T
General Services Administration Public Buildings Service
Great Lakes
BUILDING NAME
ADDRESS
CITY, STATE, ZIP
BUILDING NO.
PROJECT TITLE
GSA PROJECT NO.
SUBMISSION STAGE
SUBMISSION DATE
DRAWN BY
CHECKED BY
FLOOR NO.
DISCIPLINE
PLAN TYPE
SHEET NUMBER
AND FILENAME
KE
Y
PL
AN
GR
AP
HI
C
SC
AL
E
985 Michigan Avenue
Detroit, Michigan 48225
MI0801DF
985 Passenger Elevator
Modernization
RMI12521
BID DOCUMENTS
02/21/2022
Design and Construction, Project Delivery Division John C. Kluczynski Federal Building 230 South Dearborn St.
Chicago, IL 60604
CO
NT
RA
CT
DE
SI
GN
ER
ID
EN
TI
FIC
AT
IO
N
CONST. CONTRACT NO.
DELIVER ORDER NO.
A/E CONTRACT NO.
CO
NS
UL
TA
NT
ID
EN
TIF
IC
AT
IO
N
RE
VI
SI
ON
B
LO
CK
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY - DO NOT REMOVE THIS NOTICE - PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDEDSENSITIVE BUT UNCLASSIFIED
SENSITIVE BUT UNCLASSIFIED
MECHANICAL
985 Federal Building Parking Garage
816 E 4th ST.
Royal Oak, MI 48067 248.542.7866/www.ghfaa.com
A S S O C I A T E S A R C H I T E C T S
FLOOR PLAN
47PF0021F0046
GP-05-P13-SVD-0030
RLT
DC
M-102
ELEV MACHINE ROOM
C R
E V
I T L
O C
A L
F
IL
E S
\M I0
M
E P
L
-R
M a b ro w n
.r v t
/1
/2
:1
:1 A
M
SCALE: 1/4" = 1'-0"
ELEVATOR MACHINE ROOM MECHANICAL NEW WORK PLAN
SCALE: 1/4" = 1'-0"
ELEVATOR MACHINE ROOM MECHANICAL DEMOLITION PLAN
MECHANICAL GENERAL DEMOLITION NOTES:
1 ANY INTERRUPTION OF EXISTING SERVICES AND/OR EQUIPMENT SHALL BE PERFORMED AT A TIME
APPROVED IN ADVANCE BY THE OWNER'S REPRESENTATIVE.
2 THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL EXTENT OF THE WORK. ACTUAL ROUTING AND SIZES OF EXISTING PIPING AND DUCTWORK MIGHT DIFFER TO A LIMITED EXTENT FROM WHAT IS SHOWN. MAJOR DISCREPANCIES BETWEEN THE DRAWINGS AND ACTUAL EXISTING CONDITIONS
SHALL BE REPORTED TO THE ENGINEER.
3 THE EXACT EXTENT OF DEMOLITION SHALL BE AS REQUIRED BY THE NEW WORK.
4 ALL MECHANICAL ITEMS TO BE REMOVED SHALL BE REMOVED COMPLETE, INCLUDING ALL RELATED ITEMS
SUCH AS HANGERS, SUPPORTS, CONTROLS, ETC. CAP ALL OPEN ENDED PIPES AND DUCTWORK.
SHEET METAL GENERAL NOTES:
1 THESE DRAWINGS ARE DIAGRAMMATIC, AND REPRESENT THE GENERAL INTENT AND ARRANGEMENT OF
SYSTEMS. THEY ARE NOT TO BE CONSIDERED FABRICATION/COORDINATION/SHOP DRAWINGS.
COORDINATION WITH OTHER TRADES IS REQUIRED. PROVIDE THE ADDITIONAL FITTINGS AND OFFSETS THAT WILL BE REQUIRED TO COMPLETE EACH SYSTEM AND TO AVOID INTERFERENCES WITH ALL OTHER SYSTEMS INCLUDING THE STRUCTURE, PIPING SYSTEMS, ELECTRICAL CONDUITS, BUS DUCTS, CABLE
TRAY, LIGHT FIXTURES, ETC. AND/OR OTHER SPACE CONSTRAINTS.
2 INSTALL SYSTEMS SUCH THAT REQUIRED CLEARANCE AND SERVICE ACCESS SPACE IS PROVIDED
AROUND ALL MECHANICAL AND ELECTRICAL EQUIPMENT, AND AROUND ANY COMPONENTS WHICH
REQUIRE SERVICE ACCESS.
3 PIPING AND DUCTWORK SHALL NOT BE INSTALLED ABOVE ELECTRICAL TRANSFORMERS, SWITCHBOARDS, PANELBOARDS OR MOTOR CONTROL CENTERS.
4 COORDINATE AND PROVIDE ACCESS DOORS WITHIN INACCESSIBLE CEILING, SHAFT, AND CHASE AREAS FOR ALL COMPONENTS WHICH REQUIRE SERVICE ACCESS. REFER TO ARCHITECTURAL DRAWINGS FOR
CEILING TYPES.
5 PROVIDE SUPPLEMENTARY STEEL AS REQUIRED FOR THE PROPER SUPPORT OF ALL SYSTEMS.
# CONSTRUCTION KEY NOTES:
1 CONTRACTOR SHALL REUSE EXISTING ROOFTOP CURB AND PROVIDE A CURB ADAPTER AS REQUIRED FOR EXISTING CURB TO RECEIVE NEW ROOFTOP UNIT. MODIFY AND EXTEND EXISTING SHEET METAL TO
CONNECT TO NEW UNIT.
2 MODIFY EXISTING UNIT HEATER SET POINT TO 60 DEG. F. OR MINIMUM 5 DEG BELOW AC-PE SET POINT TO
PREVENT SIMULTANEOUS HEATING AND COOLING.
# DEMOLITION KEY NOTES:
A REMOVE EXISTING ROOF TOP UNIT (EX AC-PE) FROM ROOF, DISCONNECT POWER, TEMPERATURE CONTROLS, DUCTWORK, AND ASSOCIATED COMPONENTS COMPLETE TO FACILITATE THE INSTALLATION OF
NEW ROOFTOP UNIT. EXISTING CURB SHALL REMAIN.
B CONTRACTOR TO VERIFY EXACT LOCATION IN THE FIELD.
C REMOVE EXISTING COMPRESSED AIR PIPING AND VALVE BACK TO WITHIN WALL AND CAP. PIPING IS
LOCATED NEAR THE FINISHED FLOOR.
SCALE: 1/4" = 1'-0"
MECHANICAL ROOF PLAN
General Services Administration
Public Buildings Service
Great Lakes
985 Michigan Avenue
Detroit, Michigan 48225
MI0801DF
985 Passenger Elevator
Modernization
RMI12521
BID DOCUMENTS
02/21/2022
Design and Construction, Project Delivery Division
John C. Kluczynski Federal Building
230 South Dearborn St.
Chicago, IL 60604
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY - DO NOT REMOVE THIS NOTICE - PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
SENSITIVE BUT UNCLASSIFIED
SENSITIVE BUT UNCLASSIFIED
MECHANICAL
MARK DATE DESCRIPTION
5145 Livernois, Suite 100
Fax: 248-879-0007
Troy, Michigan 48098-3276
Tel: 248-879-5666 www.PeterBassoAssociates.com
CONSULTING ENGINEERS
Peter Basso Associates Inc
PBA Project No.: 2020-0353
47PF0021F0046
GP-05-P13-SVD-0030
N/A
985 Federal Building Parking Garage
816 E 4th ST.
Royal Oak, MI 48067
248.542.7866/www.ghfaa.com
A S S O C I A T E S A R C H I T E C T S
M-601
DC
RLT
DETAILS
Peter Basso Associates Inc
CONSULTING ENGINEERS
5145 Livernois, Suite 100
Troy, Michigan 48098-3276
Tel: 248-879-5666
Fax: 248-879-0007 www.PeterBassoAssociates.com
PBA Project No.: 2020-0353
ST
AM
P
OR
S
EA
L
OW
NE
R
ID
EN
TIF
IC
AT
IO
N
BU
ILD
IN
G
PR
OJ
EC
T
SH
EE
T
General Services Administration Public Buildings Service
Great Lakes
BUILDING NAME
ADDRESS
CITY, STATE, ZIP
BUILDING NO.
PROJECT TITLE
GSA PROJECT NO.
SUBMISSION STAGE
SUBMISSION DATE
DRAWN BY
CHECKED BY
FLOOR NO.
DISCIPLINE
PLAN TYPE
SHEET NUMBER
AND FILENAME
KE
Y
PL
AN
GR
AP
HI
C
SC
AL
E
985 Michigan Avenue
Detroit, Michigan 48225
MI0801DF
985 Passenger Elevator
Modernization
RMI12521
BID DOCUMENTS
02/21/2022
Design and Construction, Project Delivery Division John C. Kluczynski Federal Building 230 South Dearborn St.
Chicago, IL 60604
CO
NT
RA
CT
DE
SI
GN
ER
ID
EN
TI
FIC
AT
IO
N
CONST. CONTRACT NO.
DELIVER ORDER NO.
A/E CONTRACT NO.
CO
NS
UL
TA
NT
ID
EN
TIF
IC
AT
IO
N
RE
VI
SI
ON
B
LO
CK
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY - DO NOT REMOVE THIS NOTICE - PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDEDSENSITIVE BUT UNCLASSIFIED
SENSITIVE BUT UNCLASSIFIED
MECHANICAL
985 Federal Building Parking Garage
816 E 4th ST.
Royal Oak, MI 48067 248.542.7866/www.ghfaa.com
A S S O C I A T E S A R C H I T E C T S
SCHEDULES
47PF0021F0046
GP-05-P13-SVD-0030
RLT
DC
M-701
N/A
C R
E V
I T L
O C
A L
F
IL
E S
\M I0
M
E P
L
-R
M a b ro w n
.r v t
/1
/2
:1
:2 A
M
PLUMBING PIPING & VALVE APPLICATION SCHEDULE
PIPE SIZE
(INCHES)
MATERIAL PRESSURE CONNECTIONS
GRAVITY DWV
CONNECTIONS
ISOLATION
VALVES
KEYED NOTESS
O
F T
C O
P P
E R
T Y
P E
K
H A
R D
C O
P P
E R
T Y
P E
L
H A
R D
C O
P P
E R
T Y
P E
M
C A
R B
O N
S T
E E
L
S C
H E
D
C A
R B
O N
S T
E E
L
S T
D
G A
L V
S
T E
E L
S
C H
E D
S T
A
IN
L E
S S
S T
E E
L
S C
H E
D
P E
X
P E
P
IP
E
P E
S H
E A
T H
E D
C A
R B
O N
S T
E E
L P
IP
E
C S
S T
N O
-H U
B C
IS
P
P V
C T
Y P
E D
W V
P P
D R
A
IN
A G
E P
IP
E
C O
P P
E R
T Y
P E
D W
V
D U
C T
IL
E
I R
O N
P
IP
E
S O
L D
E R
E D
B R
A Z
E D
W E
L D
E D
T H
R E
A D
E D
F L A
N G
E D
G R
O O
V E
D
IN
S
E R
T
C R
IM
P
F U
S
IO
N
P R
E S
S U
R E
-S E
A L
M E
C H
A N
IC
A
L L Y
-F O
R M
E D
T E
E
M E
C H
A N
IC
A
L J
O
IN
T
P U
S H
-O N
-J O
IN
T
S O
L V
E N
T W
E L D
E D
S O
L D
E R
E D
F U
S
IO
N
C
IS
P H
U B
L E
S S
H E
A V
Y -D
U T
Y H
U B
L E
S S
B A
L L
A G
A B
A L L
G E
N E
R A
L S
E R
V
IC
E B
U T
T E
R F
L Y
L U
B R
IC
A
T E
D P
L U
G
G A
T E
UNDERGROUND SANITARY WASTE & VENT - MIN. WORKING PRESS.: 10-FOOT HEAD OF WATER
3 TO 12 X X
3 TO 12 X X
ABOVEGROUND COLD CONDENSATE DRAIN - MIN. WORKING PRESSURE: 10 FT. HEAD OF WATER
ALL SIZES X X X
DUCT SYSTEM APPLICATION SCHEDULE
AIR SYSTEMS G
G A
L V
S
H E
E T
M E
T A
L
D O
U B
L E
-W A
L L
L
IN
E D
G
G
A L V
S
H E
E T
M E
T A
L
S O
L
ID
I N
N E
R W
A L
L
D O
U B
L E
-W A
L L
L
IN
E D
G
G
A L V
S
H E
E T
M E
T A
L
P E
R F
IN
N E
R W
A L
L
G
G
A L V
S
H E
E T
M E
T A
L W
IT
H
-I
N C
H L
IN
IN
G
G A
L V
A N
N E
A L E
D S
H E
E T
M E
T A
L
A L U
M
IN
U M
T Y
P E
S T
A
IN
L E
S S
S T
E E
L
T Y
P E
S T
A
IN
L E
S S
S T
E E
L
P V
C C
O A
T E
D G
A L
V S
H E
E T
M E
T A
L
X
P V
C C
O A
T E
D G
A L
V S
H E
E T
M E
T A
L
X
P V
C C
O A
T E
D G
A L
V S
H E
E T
M E
T A
L
X
G
A C
A R
B O
N S
T E
E L
Z E
R O
-C L E
A R
A N
C E
P R
E F
A B
R
IC
A T
E D
R A
N G
E H
O O
D E
X H
A U
S T
D U
C T
F A
B R
IC
D E
S
IG
N P
R E
S S
U R
E C
L A
S S
IN
C H
E S
W G
S E
A L
C L
A S
S
M A
X A
L L
O W
A B
L E
L E
A K
A G
E R
A T
E
P E
R C
E N
T
KEYED NOTES
SUPPLY AIR WITHOUT TERMINAL UNITS X +2 A 5
RETURN AIR WITHOUT TERMINAL UNITS X -2 A 5
GENERAL NOTES:
1. 'X' INDICATES ACCEPTABLE SELECTION. IF MORE THAN ONE SELECTION IS INDICATED FOR A PIPING SYSTEM, CONTRACTOR MAY
SELECT FROM THOSE INDICATED SELECTIONS.
HORIZONTAL PIPING AND SUPPORT APPLICATION SCHEDULE
METAL PIPE TYPE & SIZE
HANGER OR SUPPORT TYPE SHIELD TYPE
KEYED NOTESM
S
S T
Y P
E
C L E
V
IS
H A
N G
E R
M S
S T
Y P
E
S
W
IV
E L R
IN
G
B A
N D
H A
N G
E R
M S
S T
Y P
E
D
O U
B L E
R O
D P
IP
E
R O
L L
E R
M S
S T
Y P
E
S
IN
G
L E
R O
D R
O L
L E
R H
A N
G E
R
M S
S T
Y P
E
P
IP
E
R O
L L E
R
S T
A N
D
M S
S T
Y P
E
A
D J U
S T
A B
L E
P
IP
E R
O L L S
T A
N D
M S
S T
Y P
E
P
R O
T E
C T
IO
N
S A
D D
L E
M S
S T
Y P
E
I N
S U
L A
T
IO
N P
R O
T E
C T
IO
N
S H
IE
L D
T H
E R
M A
L -H
A N
G E
R S
H
IE
L D
UNINSULATED SINGLE PIPE
UP TO 2 INCH X X
GENERAL NOTES:
1. 'X' INDICATES ACCEPTABLE SELECTION. IF MORE THAN ONE SELECTION IS INDICATED FOR A PIPING SYSTEM, CONTRACTOR MAY SELECT FROM THOSE INDICATED SELECTIONS.
2. DISSIMILAR-METAL PIPING JOINTS: CONSTRUCT JOINTS USING DIELECTRIC FITTINGS COMPATIBLE WITH BOTH PIPING MATERIALS.
a. NPS 2 AND SMALLER : USE DIELECTRIC NIPPLE/WATERWAY.
b. NPS 2-1/2 AND LARGER: USE DIELECTRIC FLANGE KITS.
3. USE UNIONS OR FLANGES AT VALVE AND EQUIPMENT CONNECTIONS.
4. PLUMBING EQUIPMENT DRAINS, VENTS, SAFETY VALVE PIPING, BLOWDOWN PIPING AND THE LIKE SHALL BE SAME PIPING MATERIAL AS ASSOCIATED PIPING SYSTEM.GENERAL NOTES:
1. 'X' INDICATES ACCEPTABLE SELECTION. IF MORE THAN ONE SELECTION IS INDICATED FOR A PIPING SYSTEM, CONTRACTOR MAY
SELECT FROM THOSE INDICATED SELECTIONS.
GENERAL NOTES:
1. 'X' INDICATES APPROVED HANGER OR SUPPORT ELEMENTS. IF MORE THAN ONE HANGER OR SUPPORT ELEMENT IS INDICATED, SELECTION FROM APPROVED ELEMENTS IS CONTRACTOR'S OPTION.
2. REFER TO HANGER AND SUPPORT SECTION FOR APPROVED MANUFACTURERS.
3. HANGERS AND SUPPORTS USED FOR FIRE PROTECTION SERVICES SHALL BE UL LISTED OR FMG APPROVED.
4. HANGER ELEMENTS IN CONTACT WITH BARE COPPER PIPE SHALL BE COPPER PLATED, PLASTIC COATED, FELT LINED, OR USE
MANUFACTURED COPPER TUBE ISOLATORS.
5. REFER TO INDIVIDUAL PIPING SPECIFICATION SECTIONS FOR HANGER SPACING.
6. MULTIPLE PARALLEL COLD PIPES MAY BE TRAPEZE SUPPORTED FROM BELOW USING U-BOLTS OR STRUT CLAMPS AND THERMAL
HANGER SHIELDS. REFER TO KEYED NOTE A.
7. MULTIPLE PARALLEL COLD PIPES MAY BE TRAPEZE SUPPORTED FROM ABOVE USING STANDARD HANGER ELEMENTS INDICATED FOR
SINGLE COLD PIPES.
8. MULTIPLE PARALLEL HOT PIPES MAY BE TRAPEZE SUPPORTED FROM BELOW USING ROLLER ELEMENTS AND THERMAL HANGER
SHIELD OR INSULATION PROTECTION SADDLE. REFER TO KEYED NOTES B AND C.
9. MULTIPLE PARALLEL HOT PIPES MAY BE TRAPEZE SUPPORTED FROM ABOVE USING STANDARD ROLLER HANGERS INDICATED AND
THERMAL HANGER SHIELD OR INSULATION PROTECTION SADDLE. REFER TO KEY NOTES B AND C.
10. REFER TO INDIVIDUAL PIPING SPECIFICATION SECTIONS FOR ADDITIONAL SYSTEM SPECIFIC HANGER APPLICATIONS.
Peter Basso Associates Inc
CONSULTING ENGINEERS
5145 Livernois, Suite 100
Troy, Michigan 48098-3276
Tel: 248-879-5666
Fax: 248-879-0007 www.PeterBassoAssociates.com
PBA Project No.: 2020-0353
ST
AM
P
OR
S
EA
L
OW
NE
R
ID
EN
TIF
IC
AT
IO
N
BU
ILD
IN
G
PR
OJ
EC
T
SH
EE
T
General Services Administration Public Buildings Service
Great Lakes
BUILDING NAME
ADDRESS
CITY, STATE, ZIP
BUILDING NO.
PROJECT TITLE
GSA PROJECT NO.
SUBMISSION STAGE
SUBMISSION DATE
DRAWN BY
CHECKED BY
FLOOR NO.
DISCIPLINE
PLAN TYPE
SHEET NUMBER
AND FILENAME
KE
Y
PL
AN
GR
AP
HI
C
SC
AL
E
985 Michigan Avenue
Detroit, Michigan 48225
MI0801DF
985 Passenger Elevator
Modernization
RMI12521
BID DOCUMENTS
02/21/2022
Design and Construction, Project Delivery Division John C. Kluczynski Federal Building 230 South Dearborn St.
Chicago, IL 60604
CO
NT
RA
CT
DE
SI
GN
ER
ID
EN
TI
FIC
AT
IO
N
CONST. CONTRACT NO.
DELIVER ORDER NO.
A/E CONTRACT NO.
CO
NS
UL
TA
NT
ID
EN
TIF
IC
AT
IO
N
RE
VI
SI
ON
B
LO
CK
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY - DO NOT REMOVE THIS NOTICE - PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDEDSENSITIVE BUT UNCLASSIFIED
SENSITIVE BUT UNCLASSIFIED
MECHANICAL
985 Federal Building Parking Garage
816 E 4th ST.
Royal Oak, MI 48067 248.542.7866/www.ghfaa.com
A S S O C I A T E S A R C H I T E C T S
SCHEDULES
47PF0021F0046
GP-05-P13-SVD-0030
RLT
DC
M-702
N/A
C R
E V
I T L
O C
A L
F
IL
E S
\M I0
M
E P
L
-R
M a b ro w n
.r v t
/1
/2
:1
:3 A
M
UNITARY ROOFTOP AIR CONDITIONING UNIT SCHEDULE - PART A
UNIT
DESIGNATION
AREA SERVED
SUPPLY FAN COOLING SECTION - DX
INTEGRAL AIR-COOLED CONDENSING
SECTION
MODEL
NUMBER
KEYED
NOTESDES. NO. AIRFLOW CFM
MINIMUM
OUTSIDE AIR
FLOW CFM E.S.P. IN. W.G.
FAN SUCTION OR
DISCHARGE S.P. IN. W.G. AT
COOLING COIL DRAIN PAN T.S.P. IN. W.G.
FAN SPEED
RPM BHP HP
MIXED AIR UNIT LEAVING AIR NET UNIT CAPACITY
NUMBER OF
CIRCUITS REFRIG. TYPE
MAX. FACE
VEL. F.P.M.
DESIGN
AMBIENT
TEMP. °F
MIN. AMBIENT
TEMP. °F
CAPACITY
CONTROL
STAGESE.D.B. °F E.W.B. °F L.D.B. °F L.W.B. °F TOTAL MBH
SENSIBLE
MBH
AC PE ELEVATOR MACHINE ROOM 2200 220 0.50 1.14 1.64 2481 1.6 2.4 81.0 66.5 58.0 57.8 59.7 59.5 1 R-410 500 95 0 MODULATING 50JC
UNITARY ROOFTOP AIR CONDITIONING UNIT SCHEDULE - PART B
UNIT
DESIGNATION
AREA SERVED
FILTER SECTION ROOF CURB MAXIMUM UNIT DIMENSIONS MAXIMUM UNIT
OPERATING
WEIGHT LBS.
(WITH CURB
ADAPTOR)
TOTAL UNIT ELECTRICAL
MODEL
NUMBER
KEYED
NOTESDES. NO. TYPE MERV
AIR PRESS. DROP TYPE
HEIGHT
LENGTH
INCHES
HEIGHT (WITH
CURB
ADAPTOR)
INCHES
WIDTH
INCHES VOLTS PHASE MCA MOP
SCCR
KA
OPTIONS /
ACCESSORIES
INITIAL IN.
W.G. FINAL IN. W.G. STANDARD
VIBRATION
ISOLATION
SPRING CURB
AC PE ELEVATOR MACHINE ROOM THROWAWAY 11 0.50 1.00 --- --- 0 74 3/8" 65 3/8" 46 1/2" 811 460 3 15 20 5 B 50JC
PLUMBING CONNECTION SCHEDULE
UNIT IDENTIFICATION
CW INCHES HW INCHES SAN INCHES VENT INCHES
KEYED
NOTESDES. NO.
TD 1 - - 4 -
SCHEDULES GENERAL NOTES:
TYPICAL FOR ALL SCHEDULE SHEETS:
1 REFER TO ELECTRICAL STANDARD SCHEDULES, ONE LINE DIAGRAM AND PANEL
SCHEDULES FOR ADDITIONAL ELECTRICAL INFORMATION
2 PROVIDE THE FOLLOWING FACTORY-WIRED ELECTRICAL OPTIONS/ACCESSORIES
WHERE INDICATED IN SCHEDULE:
A - NON-FUSED DISCONNECT SWITCH
B - UNIT SHALL BE SINGLE POINT ELECTRICAL CONNECTION WITH FACTORY
INSTALLED DISCONNECTING MEANS AND ALL REQUIRED STARTERS AND
CONTROLS
C - SERVICE RECEPTACLE
D - FUSED DISCONNECT SWITCH
E - COMBINATION STARTER
F - UNIT SHALL HAVE (2) SINGLE POINT CONNECTIONS WITH FACTORY INSTALLED
DISCONNECTING MEANS AND ALL REQUIRED STARTERS AND CONTROLS. (1)
CONNECTION SHALL BE FOR CONDENSING SECTION AND (1) CONNECTION SHALL BE
FOR THE REMAINDER OF THE UNIT.
3 FOR MODULATION/CONTROL TYPE COLUMN, "VFC" INDICATES VARIABLE FREQUENCY
CONTROLLERS, "AUTO" INDICATES AUTOMATIC OPERATION (CONTROLLED BY
TEMPERATURE CONTROLS OR SELF CONTAINED CONTROLS), "MANUAL" INDICATES
HAND OPERATION.
4 IF VARIABLE FREQUENCY CONTROLLERS ARE INDICATED TO BE PROVIDED AND ARE
NOT INSTALLED INTEGRAL TO THE UNIT, VARIABLE FREQUENCY CONTROLLERS SHALL
BE SUPPLIED BY THE MECHANICAL CONTRACTOR (UNLESS OTHERWISE NOTED) AND
INSTALLED BY THE ELECTRICAL CONTRACTOR INCLUDING THE LINE SIDE AND LOAD
SIDE WIRING TO THE MOTOR AND INCLUDING MISCELLANEOUS STEEL REQUIRED FOR
THE SUPPORT AND MOUNTING OF THE VFC. REFER TO FLOOR PLANS FOR LOCATION.
5 WHERE EQUIPMENT IS INDICATED TO HAVE A SINGLE POINT ELECTRICAL
CONNECTION, THAT EQUIPMENT SHALL COME COMPLETE WITH FACTORY INSTALLED
STARTERS, MOTOR OVERLOAD PROTECTION, CONTACTORS, FUSING AND ALL
NECESSARY INTERNAL WIRING AND CONTROLS. PROVIDE A FACTORY MOUNTED UNIT
DISCONNECTING MEANS WHERE THE ELECTRICAL CONTRACTOR SHALL MAKE SINGLE
POINT CONNECTION. INSTALL PACKAGED EQUIPMENT SUCH THAT THE ELECTRICAL
CONNECTION AND CONTROLS ARE ACCESSIBLE AND HAVE CLEARANCES MEETING
THE NATIONAL ELECTRICAL CODE.
6 WHERE PACKAGED EQUIPMENT IS PROVIDED, NAMEPLATE MUST INDICATE MAXIMUM
OVERCURRENT PROTECTION BY HACR RATED CIRCUIT BREAKERS OR FUSES. IF
FUSE PROTECTION ONLY IS INDICATED, PROVIDE A FUSIBLE DISCONNECT AND FUSES
WITH THE UNIT.
7 WHERE EQUIPMENT IS DESIGNATED BY MANUFACTURER AND MODEL NUMBER, THIS
IS THE BASIS OF DESIGN. IF THE CONTRACTOR ELECTS TO PROVIDE EQUIPMENT BY
OTHER SPECIFIED MANUFACTURERS OR PROPOSED ALTERNATE EQUIPMENT BY THE
BASIS OF DESIGN MANUFACTURER, THE CONTRACTOR SHALL BE RESPONSIBLE FOR
ANY REVISIONS TO ELECTRICAL REQUIREMENTS, STRUCTURAL LOADING, OR
ARCHITECTURAL APPURTENANCES AND SHALL INCLUDE THE COST OF SUCH
REVISIONS IN HIS BID.
8 WHERE EQUIPMENT IS SCHEDULED TO INCLUDE A SERVICE RECEPTACLE, PROVIDE A
FACTORY MOUNTED SERVICE RECEPTACLE WITH APPROPRIATE FUSES AND
TRANSFORMERS CONNECTED ON THE LINE SIDE OF THE UNIT DISCONNECT. PROVIDE
A NAMEPLATE ON THE DISCONNECT SWITCH INDICATING THE PRESENCE OF LIVE
POWER TO THE SERVICE RECEPTACLE WHEN HE UNIT DISCONNECT IS IN THE OFF
POSITION.
9 <<< DESIGNER NOTE: STANDARD MECHANICAL SPECIFICATIONS INDICATE THAT
SERVICE RECEPTACLES ARE FACTORY WIRED. IF THIS NOTE NEEDS TO CHANGE SO
THAT SERVICE RECEPTACLES ARE POWERED BY INDIVIDUAL 120V CIRCUITS, PLEASE
COORDINATE THIS CHANGE WITH THE MECHANICAL SPECIFICATIONS SECTIONS.
>>> SIZE ALL EQUIPMENT FEEDERS BASED ON THE LISTED MOP (MAXIMUM
OVERCURRENT PROTECTION). REFER TO THE FEEDER AND BRANCH CIRCUIT SIZING
SCHEDULE ON THE ELECTRICAL STANDARD SCHEDULES SHEET.
GENERAL NOTES:
1. REFER TO SCHEDULES GENERAL NOTES.
2. MODEL NUMBERS ARE CARRIER UNLESS OTHERWISE NOTED
3. DESIGN MINIMUM OUTSIDE AIRFLOW CFM (VENTILATION) LISTED IS BASED ON THE ESTIMATED MAXIMUM OCCUPANT LOAD. REFER TO TEMPERATURE CONTROL DRAWINGS FOR OUTSIDE AIR CONTROL SEQUENCE.
4. MERV DESIGNATES THE "MINIMUM EFFICIENCY REPORTING VALUE" AS EVALUATED UNDER ASHRAE STANDARD 52.2 1999.
5. AIR HANDLING UNIT TOTAL STATIC PRESSURE IS BASED ON THE FINAL FILTER AIR PRESSURE DROP.
6. CONTRACTOR SHALL UTILIZE EXISTING ROOF CURB AND PROVIDE CURB ADAPTOR IF REQUIRED.
7. PROVIDE 100% ECONOMIZER AND BAROMETRIC RELIEF.
8. UNIT SHALL BE SINGLE ZONE VARIABLE AIR VOLUME WITH MODULATING COOLING CAPACITY CONTROL.
9. PROVIDE CONDENSATE OVERFLOW SWITCH.
10. ALTERNATES SHALL NOT EXCEED THE MAXIMUM WEIGHT OF 862 LBS INCLUDING WEIGHT OF EXISTING ROOF CURB AND CURB ADAPTOR.
GENERAL NOTES:
1. INDIVIDUAL WATER LINE BRANCHES, WASTE LINES, VENTS, AND TRAPS FOR
CONNECTION TO INDIVIDUAL FIXTURES, FIXTURE FITTINGS, AND SPECIALTIES SHALL
BE IN ACCORDANCE WITH THE FOLLOWING SCHEDULE OR AS INDICATED ON
DRAWINGS, WHICHEVER IS GREATER.
General Services Administration
Public Buildings Service
Great Lakes
985 Michigan Avenue
Detroit, Michigan 48225
MI0801DF
985 Passenger Elevator
Modernization
RMI12521
BID DOCUMENTS
02/21/2022
Design and Construction, Project Delivery Division
John C. Kluczynski Federal Building
230 South Dearborn St.
Chicago, IL 60604
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY - DO NOT REMOVE THIS NOTICE - PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
SENSITIVE BUT UNCLASSIFIED
SENSITIVE BUT UNCLASSIFIED
MECHANICAL
MARK DATE DESCRIPTION
5145 Livernois, Suite 100
Fax: 248-879-0007
Troy, Michigan 48098-3276
Tel: 248-879-5666 www.PeterBassoAssociates.com
CONSULTING ENGINEERS
Peter Basso Associates Inc
PBA Project No.: 2020-0353
47PF0021F0046
GP-05-P13-SVD-0030
N/A
985 Federal Building Parking Garage
816 E 4th ST.
Royal Oak, MI 48067
248.542.7866/www.ghfaa.com
A S S O C I A T E S A R C H I T E C T S
M-801
DC
DJT
TEMPERATURE CONTROLS
Great Lakes
985 Michigan Avenue
Detroit, Michigan 48225
MI0801DF
985 Passenger Elevator
Modernization
RMI12521
BID DOCUMENTS
02/21/2022
Design and Construction, Project Delivery Division
John C. Kluczynski Federal Building
230 South Dearborn St.
Chicago, IL 60604
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY - DO NOT REMOVE THIS NOTICE - PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
SENSITIVE BUT UNCLASSIFIED
SENSITIVE BUT UNCLASSIFIED
MECHANICAL
MARK DATE DESCRIPTION
5145 Livernois, Suite 100
Fax: 248-879-0007
Troy, Michigan 48098-3276
Tel: 248-879-5666 www.PeterBassoAssociates.com
CONSULTING ENGINEERS
Peter Basso Associates Inc
PBA Project No.: 2020-0353
47PF0021F0046
GP-05-P13-SVD-0030
N/A
985 Federal Building Parking Garage
816 E 4th ST.
Royal Oak, MI 48067
248.542.7866/www.ghfaa.com
A S S O C I A T E S A R C H I T E C T S
M-802
DC
DJT
TEMPERATURE CONTROLS
U
P L E
X R
E C
E P
T A
C L E
D U
P L E
X T
A M
P E
R R
E S
IS
T
A N
T R
E C
E P
T A
C L E
D U
P L E
X G
F C
I R
E C
E P
T A
C L E
F U
T U
R E
T E
L E
C O
M M
U N
IC
A
T
IO
N O
U T
L E
T
T E
L E
C O
M M
U N
IC
A
T
IO
N O
U T
L E
T
8" ABOVE COUNTER TO
CENTER…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .