Drawings - 3B Thumb.pdf

PDF 757 KB Posted

Attached to
472/17398. SMD Bid Pkg 3 Razor Ribbon Project - Various CFs
Solicitation number
RFQ-171-180000000615-4
Issued by
Kalamazoo County, Michigan

About this file

This is a set of architectural drawings for perimeter fence enhancements at the Thumb Correctional Facility in Lapeer, Michigan, prepared by Matrix Consulting Engineers, Inc. The project (Index #34660, File #472/17398.SMD, Matrix Project #17301.00) involves security fence modifications at 3225 John Conley Drive. The drawings detail various fence improvements including the addition of detainer hook razor ribbon with 12" loop spacing, modifications to existing interior and exterior security fences (referred to as "A" and "B" fences), and alterations to existing stun fencing systems.

The technical drawings show site plans, fence details, and gate specifications with multiple cross-sections depicting fence configurations ranging from 12' to 17'8" in height. The plans include detailed specifications for razor wire installation, fence post placement, and security measures such as instabarrier razor ribbon installations. The drawings contain various fence details showing both existing conditions and proposed enhancements, particularly focusing on the integration of new razor ribbon systems with existing security infrastructure.

View the file

Other files

File Type Posted
Specifications - 3B 17398.pdf PDF
Drawings - 3B Egeler.pdf PDF
Drawings - 3B Lakeland.pdf PDF
Drawings - 3B Parnall.pdf PDF
LEIN Request REV 04-2018 Bid Pkg 3.pdf PDF
Addendum 1 Bid Pack 3B.pdf PDF
Addendum 2 Bid Pack 3B - SIGMA.pdf PDF
Addendum 3 Bid Pack 3B.pdf PDF
Drawings - 3B Gus Harrison.pdf PDF
Advertisement Bid Pkg 3B 17398.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A-000

JKB

JFS

file no.

checked by drawn by consultant issue date index no.

contract order no.

34660 consultant job no.

17301.00 sheet title

472/17398.SMD

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

50% REVIEW SET 03/19/2018

BID SET 05/11/2018

C-100

JKB

JFS

N file no.

checked by drawn by consultant issue date index no.

contract order no.

34660 consultant job no.

17301.00 sheet title

472/17398.SMD

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

FENCING AND GATES NOTES

1. ALL FABRIC, RAILS, POSTS, GATES AND FITTINGS SHALL BE HOT-DIPPED GALVANIZED

STEEL WITH ZINC COATING, UNLESS NOTED OTHERWISE. ALL FABRIC SHALL BE 2"

DIAMOND MESH.

2. ALL CHAIN LINK FENCE, GATE AND COMPONENTS SHALL HAVE GALVANIZED FINISH.

3. ALL FENCING TO BE KNUCKLED TOP AND BOTTOM.

4. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR ALL FENCING.

5. ALL FRAMES SHALL BE CONSTRUCTED IN SHOP. CONTRACTOR SHALL FIELD-MEASURE

POSTS PRIOR TO CONSTRUCTION.

6. ALL GATE FRAMES SHALL BE CONSTRUCTED WITH WELD CUPPED JOINTS (FISH MOUTH).

7. ALL WELDS SHALL BE CLEAN, UNIFORM, CONTINUOUS AND FREE OF RUST. GRIND

WELDS SMOOTH AND CLEAN PRIOR TO APPLICATION OF GALVANIZED FINISH.

GRADE

EXISTING INTERIOR

"A" FENCE

EXISTING EXTERIOR

"B" FENCE

EXISTING SPOOLS,

TYP

17'-8" x x x x x x x x x x x x x

12'-0" x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

EXISTING SPOOLS,

TYP

x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

EXISTING SPOOLS,

TYP

x x x x x x x x x x x x x x x x x x x x x x x x x x

12'-0" x x x x x x x x x x x x x

ADD DETAINER HOOK

RAZOR RIBBON w/ 12"

LOOP SPACING 36

x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

ADD DETAINER HOOK

RAZOR RIBBON w/ 12"

LOOP SPACING

ADD INSTABARRIER

RAZOR RIBBON w/ 12"

LOOP SPACING

APPROACH

GATOR

8'-4"

GRADE

EXISTING INTERIOR

"A" FENCE

EXISTING EXTERIOR

"B" FENCE

EXISTING SPOOLS,

TYP

17'-8" x x x x x x x x x x x x x

12'-0" x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

EXISTING SPOOLS,

TYP

x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

EXISTING SPOOLS,

TYP

x x x x x x x x x x x x x

12'-0" x x x x x x x x x x x x x

ADD DETAINER HOOK

RAZOR RIBBON w/ 12"

LOOP SPACING 36

x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

ADD DETAINER HOOK

RAZOR RIBBON w/ 12"

LOOP SPACING

ADD INSTABARRIER

RAZOR RIBBON w/ 12"

LOOP SPACING

APPROACH

GATOR

8'-4" x x x x x x x x x x x x x

REMOVE EXISTING

RAZOR RIBBON AND

REPLACE WITH

DETAINER HOOK

RAZOR RIBBON w/12"

LOOP SPACING

GRADE

EXISTING INTERIOR

FENCE

EXISTING SPOOLS,

TYP

x x x x x x x x x x x x x

12'-0" x x x x x x x x x x x x x

ADD DETAINER HOOK

RAZOR RIBBON w/12"

LOOP SPACING

x x x x x x x x x x x x x

GRADE

EXISTING INTERIOR

FENCE

EXISTING SPOOL

12'-0" x x x x x x x x x x x x x

ADD DETAINER HOOK

RAZOR RIBBON w/12"

LOOP SPACING

x x x x x x x x x x x x x x x x x x x x x x x x x x

ADD DETAINER HOOK

RAZOR RIBBON w/12"

LOOP SPACING

GRADE

EXISTING INTERIOR

FENCE

12'-0" x x x x x x x x x x x x x

ADD DETAINER HOOK

RAZOR RIBBON w/12"

LOOP SPACING

x x x x x x x x x x x x x

ADD DETAINER HOOK

RAZOR RIBBON w/12"

LOOP SPACING

x x x x x x x x x x x x x

GRADE

EXISTING INTERIOR

FENCE

EXISTING SPOOL

x x x x x x x x x x x x x

12'-0" x x x x x x x x x x x x x

ADD DETAINER HOOK

RAZOR RIBBON w/12"

LOOP SPACING

x x x x x x x x x x x x x

EXISTING SPOOL

x x x x x x x x x x x x x

EXISTING BUILDING

EXISTING SPOOL

x x x x x x x x x x x x x

NEW 31" DETAINER

HOOK RAZOR RIBBON

@ 12" OC

EXISTING STUN

FENCE

x x x x x x x x x x x x x

EXISTING BUILDING

EXISTING SPOOL31

x x x x x x x x x x x x x

NEW 31" DETAINER

HOOK RAZOR RIBBON

@ 12" OC

EXISTING STUN

FENCE

x x x x x x x x x x x x x

EXISTING BUILDING

x x x x x x x x x x x x x

EXISTING RAZOR

RIBBON REMOVED,

ADD NEW 31"

DETAINER HOOK

RAZOR RIBBON @ 12"

OC

EXISTING STUN

FENCE

x x x x x x x x x x x x x

6'-0"

6'-0"

12'-0""

6'-0"

1/4" PLATE STEEL

GUSSET (TYP.)

FENCE

SUPPORT POST (TYP)

4'-0" X 6'-8"

MAN GATE

6'-0"

STEEL PLATE

AROUND BOTTOM

OF GATE - REFER

TO DETAIL ON SITE.

10 TYPICAL MAN GATE DETAIL

SCALE: N.T.S.

x x x x x x x x x x x x x x x x x x x x x x x x x x

C-200

JKB

JFS

file no.

checked by drawn by consultant issue date index no.

contract order no.

34660 consultant job no.

17301.00 sheet title

472/17398.SMD

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

File details come from the government source that posted it. Updated .