Drawings 22225 (Coldwater).pdf
PDF 1 MB Posted
- Solicitation number
- RFQ - 171 - 230000000023
- Issued by
- Branch County, Michigan
About this file
This document is a set of technical drawings and specifications for a roof replacement project for the Coldwater, Michigan State Police Post. The project involves the removal of the existing roof, including the membrane, insulation, and related components, and the installation of a new roof system including a fluid-applied cap, modified bitumen base, roof cover board, rigid insulation, and related components. The project scope includes the replacement of gutters, downspouts, and other roof accessories. The drawings provide detailed plans, sections, and specifications for the new roof system.
The project is being procured by the State of Michigan through a competitive bidding process. The solicitation is identified as 551/22125. SMD; Coldwater Detachment - Roof Replacement Project. The project is located in Branch County, Michigan. The bid submission deadline and other key dates are not provided in the document. The contract term and any renewal options are also not specified.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
± 141'-11"
± 134'-3"± 25'-8"
± 38'-3"
EXHAUST FAN
CONDENSATE VENT
TO BE REMOVED
CONDENSATE VENT
TO BE REMOVED
CONDENSATE VENT
TO BE REMOVED
CONDENSATE VENT
TO BE REMOVED
EXHAUST FAN
EXHAUST
FAN
CONDENSATE VENT
TO BE REMOVED
VTR
VTR
VTR
CONDENSATE
VENT TO BE
REMOVED
EXHAUST FAN
CV
VTR
CV
EXHAUST FAN
EXHAUST FAN
MECH. UNIT
VTR
VTR
E X
IS
T.
R O
O F
D E
C K
IS
S
LO
P
E D
E X
IS
T.
R O
O F
D E
C K
IS
S
LO
P
E D
E X
IS
T.
R O
O F
D E
C K
IS
S
LO
P
E D
E X
IS
T.
R O
O F
D E
C K
IS
S
LO
P
E D
VALLEY
VALLEY
VALLEY
VALLEY
HIP HIP
H
IP
H
IP
1/4" SLOPE
1/4 " S
LO
PE
1/4 " S
LO
PE
1/4" SLOPE
VTR
VTR
VTR
VTR VTR
VTR
CONDENSATE
VENT TO BE
REMOVED
CONDENSATE
VENT TO BE
REMOVED
CONDENSATE
VENT TO BE
REMOVED
CONDENSATE
VENT TO BE
REMOVED
CONDENSATE
VENT TO BE
REMOVED
CONDENSATE
VENT TO BE
REMOVED
EXIST. R
OOF
LEVEL ± 13"
EXIST. R
OOF
LEVEL ± 25"
VTR
EXIST. R
OOF
LEVEL 0"
A D
D E
D T
A P
P E
R
IN
S U
LA
TI
O N
TH
IS
A
R E
A
/8
S
LO
P E
EXIST. ROOF
DECK IS SLOPED
EXIST. ROOF
DECK IS SLOPED
EXIST. ROOF
DECK IS SLOPED
NEW GUTTER
NEW DOWNSPOUT,
PRE-FINISHED GRAY
NEW GUTTER
NEW DOWNSPOUT,
PRE-FINISHED GRAY
EXIST. LIGHT FIXTURE TO
BE REMOVED FOR NEW
WORK AND RE-INSTALLED
EXIST. ELECTRICAL
CONDUIT TO BE
REMOVED BY OWNER
NEW DOWNSPOUT,
PRE-FINISHED GRAY
NEW GUTTER
NEW DOWNSPOUT,
PRE-FINISHED GRAY
EXIST. LIGHT FIXTURE TO
BE REMOVED BY OWNER
NEW DOWNSPOUT,
PRE-FINISHED GRAY
EXIST. LIGHT FIXTURE TO
BE REMOVED BY OWNER
A900
A900
A900
A900
A900
A900
A900
A900
A900
A900
A900
A900
THIS ROOF HAS AN
OVERHANG ABOVE
THE LOWER ROOF
A901
A901
A901
A901
A901
A901
A901
A901
A901
A901
A901
A901
100-MIL FLUID APPLIED CAP
80-MIL MOD BIT BASE
1/2" DENS DECK
TAPERED INSULATION
NEW 6" BASE LAYER OF POLY-ISO R-30
WOOD DECK
145-MIL MINERAL MOD BIT CAP
80-MIL MOD BIT BASE
1/2" DENS DECK
TAPERED INSULATION
NEW 6" BASE LAYER OF POLY-ISO R-30
WOOD DECK
ROOF PLAN LEGEND
TAPERED INSULATION: PROVIDE
1/4" PER 1'-0" MIN. SLOPE TO DRAINS
AND DIVERT WATER AROUND ITEMS.
1. CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER FLASHING OF ALL
DRAINS, CURBS, VENT STACKS, ETC.
2. ROOF INSULATION TO BE 6" MINIMUM.
3. TAPERED INSULATION: MAINTAIN 1/4" PER 1'-0" MINIMUM SLOPE TO DRAINS
UNLESS NOTED, COORDINATE SLOPES TO DIRECT RUN OFF AROUND ALL
OBSTICLES INCLUDING ROOF PERIMTER OUTLINE, MECHANICAL EQUIPMENT,
SKYLIGHTS, CURBS, ETC. FINAL DESIGN SHALL BE THE RESPONSIBILITY OF
THE CONTRACTOR. MAINTAIN SLOPE UNDER ALL ABOVE ROOF ITEMS
INCLUDING RAISED PAVERS, LIVE ROOF AREA, SOLAR PANELS, ETC.
4. EXIST. ROOF MEMBRANE AND INSULATION IS TO BE REMOVED TO EXIST.
DECK INCLUDING ALL EXTRA ROOF LAYERS FOR NEW ROOF CONSTRUCTION.
5. EXIST. FASCIA TRIM, GUTTER, AND DOWNSPOUTS ARE TO BE REMOVED FOR
NEW CONSTRUCTION.
6. R-30 6" OF RIGID INSULATION IS THE BASE WITH TAPPER INSULATION ON TOP
OF. CANT USE AVERAGING OF THE R-VALUE ACROSS THE ROOF.
7. EXTEND ALL VENTS AND FANS AS REQUIRED FOR INCREASED ROOF
HEIGHT.
ROOF PLAN NOTES:
P lo tt ed
B y:
A ut od es k D oc s:
//2
S
O M
M S
P C ol dw at er
R oo f R ep la ce m en t/2
S
O M
M S
P C ol dw at er
R oo f R ep la ce m en t_ A rc h_
R
.r vt
/1
4/
:2 6:
P
M
A300 22100223
E S ta te
S t, C ol dw at er , M
I 4
C o ld w at er
M ic h ig an S ta te
P o lic e
P o st
R oo f R ep la ce m en t f or
IS
S
U E
D F
O R
B
ID
D
IN
G
.1
0.
P ro je ct
C o ve r
R o o f P la n
DRAWING LIST
Roof Replacement for:
Coldwater Michigan State Police Post 186 E State St, Coldwater, MI 49036
A300 Project Cover & Roof Plan
A900 Project Photo Sheet
A901 Roof Sections
SCALE: 1/8" = 1'-0"
OVERALL ROOF PLAN
A300
3 ALTERNATE BID
A300
2 BASE BID
P lo tt ed
B y:
A ut od es k D oc s:
//2
S
O M
M S
P C ol dw at er
R oo f R ep la ce m en t/2
S
O M
M S
P C ol dw at er
R oo f R ep la ce m en t_ A rc h_
R
.r vt
/1
4/
:2 6:
P
M
A900 22100223
E S ta te
S t, C ol dw at er , M
I 4
C o ld w at er
M ic h ig an S ta te
P o lic e
P o st
R oo f R ep la ce m en t f or
IS
S
U E
D F
O R
B
ID
D
IN
G
.1
0.
P ro je ct
P h o to
S h ee t
A900
1 PHOTO 1
A900
2 PHOTO 2
A900
3 PHOTO 3
A900
4 PHOTO 4
A900
5 PHOTO 5
A900
6 PHOTO 6
A900
7 PHOTO 7
A900
8 PHOTO 8
A900
9 PHOTO 9
A900
10 PHOTO 10
A900
11 PHOTO 11
A900
12 PHOTO 12
ROOF MEMBRANE
ROOF COVER BOARD
2X6 WOMANIZED BLOCKING
R-30, ± 6" RIGID INSULATION
NEW DRIP EDGE ALUMINUM
PRE-FINISHED DARK BLUE TO
MATCH EXIST.
NEW 3/4" WOMANIZED PLYWOOD
EXTENSION OF EXIST.
NEW FASCIA TRIM ALUMINUM PRE-
FINISHED DARK BLUE TO MATCH EXIST.
SEALANT
EXIST. DECK
EXIST. WALL FRAMING
EXIST. FASCIA BLOCKING
ROOF MEMBRANE
ROOF COVER BOARD
2X6 WOMANIZED BLOCKING
R-30, ± 6" RIGID INSULATION
NEW DRIP EDGE ALUMINUM
PRE-FINISHED DARK BLUE TO
MATCH EXIST.
NEW 3/4" WOMANIZED PLYWOOD
EXTENSION OF EXIST.
NEW FASCIA TRIM ALUMINUM PRE-
FINISHED DARK BLUE TO MATCH EXIST.
SEALANT
EXIST. DECK
EXIST. WALL FRAMING
EXIST. FASCIA BLOCKING
NEW 6X6 ALUMINUM GUTTER PRE-
FINISHED DARK BLUE TO MATCH EXIST.
ROOF MEMBRANE
ROOF COVER BOARD
2X6 WOMANIZED BLOCKING
R-30, ± 6" RIGID INSULATION
NEW DRIP EDGE ALUMINUM
PRE-FINISHED DARK BLUE TO
MATCH EXIST.
NEW 3/4" WOMANIZED PLYWOOD
EXTENSION OF EXIST.
NEW FASCIA TRIM ALUMINUM PRE-
FINISHED DARK BLUE TO MATCH EXIST.
SEALANT
EXIST. DECK
EXIST. WALL FRAMING
EXIST. FASCIA BLOCKING
TAPPERED RIGID INSULATION
ROOF MEMBRANE
ROOF COVER BOARD
2X6 WOMANIZED BLOCKING
R-30, ± 6" RIGID INSULATION
NEW DRIP EDGE ALUMINUM
PRE-FINISHED DARK BLUE TO
MATCH EXIST.
NEW 3/4" WOMANIZED PLYWOOD
EXTENSION OF EXIST.
NEW FASCIA TRIM ALUMINUM PRE-
FINISHED DARK BLUE TO MATCH EXIST.
SEALANT
EXIST. DECK
EXIST. WALL FRAMING
EXIST. FASCIA BLOCKING
ROOF MEMBRANE
ROOF MEMBRANE
ROOF COVER BOARD
2X6 WOMANIZED BLOCKING
NEW DRIP EDGE ALUMINUM
PRE-FINISHED DARK BLUE TO
MATCH EXIST.
EXIST. DECK
EXIST. WALL FRAMING
ROOF MEMBRANE
P lo tt ed
B y:
A ut od es k D oc s:
//2
S
O M
M S
P C ol dw at er
R oo f R ep la ce m en t/2
S
O M
M S
P C ol dw at er
R oo f R ep la ce m en t_ A rc h_
R
.r vt
/1
4/
:2 6:
P
M
A901 22100223
E S ta te
S t, C ol dw at er , M
I 4
C o ld w at er
M ic h ig an S ta te
P o lic e
P o st
R oo f R ep la ce m en t f or
IS
S
U E
D F
O R
B
ID
D
IN
G
.1
0.
R o o f
S ec ti o n s
SCALE: 3" = 1'-0"A901
1 ROOF PLAN - SECTION 1
SCALE: 3" = 1'-0"A901
2 ROOF PLAN - SECTION 2
SCALE: 3" = 1'-0"A901
3 ROOF PLAN - SECTION 3
SCALE: 3" = 1'-0"A901
4 ROOF PLAN - SECTION 4
SCALE: 3" = 1'-0"A901
5 ROOF PLAN - SECTION 5
| Sheets |
| A300 - Project Cover & Roof Plan |
| A900 - Project Photo Sheet |
| A901 - Roof Sections |
File details come from the government source that posted it. Updated .