Drawings_10531.pdf

PDF 38 MB Posted

Attached to
25-322011. PMDB. Window Systems Repair
Solicitation number
0000039706
Issued by
Yolo County, California

About this file

This is a set of construction drawings and specifications for a window systems repair project at the California School for the Blind in Fremont, California, prepared by the California Department of General Services (DGS) and the California Department of Education (CDE). The project involves modifications to four buildings (53, 60, 64, and 66) at the 500 Walnut Avenue campus in Alameda County. Building 53 (Education Building) requires removal of a sloped window system and replacement with a vertical storefront system, addition of roof structure and roofing, removal and replacement of VCT flooring, addition of interior lighting, removal and replacement of kitchen cabinetry, and accessibility improvements. Building 60 (Administration Building) requires removal of a sloped window system at the lobby and replacement with a vertical storefront system, roof structure and roofing addition, interior lighting, roofing system replacement, and accessibility improvements to restrooms. Building 64 (Gymnasium/Recreation Building) requires replacement of a projected window assembly with a storefront window system, exterior surface refinishing, roofing replacement at the balcony, and accessibility improvements. Building 66 (Pool Building) requires removal and replacement of damaged glass block units, replacement or reinstallation of backer and expansion rods, re-pointing of grout joints, and stripping and refinishing of exposed steel frames. The project is governed by the 2022 California Building Code and related standards, with Division of the State Architect (DSA) certification required. Sealed bids are due July 29, 2026, at 2:00 P.M. at DGS/OBAS, 707 Third Street, West Sacramento, California 95605.

A California B license is required to bid this project (DSA Application No. 01-122002, Project No. 000000000010531). Contractors must submit valid Certificates of Reported Compliance (CRCs) for any fleet vehicles subject to California Air Resources Board In-Use Off-Road Diesel Fueled Fleet Regulations. The successful bidder must furnish payment and performance bonds each in the amount of 100 percent of the contract price. All contractors and subcontractors must comply with applicable health and safety mandates issued by federal, state, and local governments, with costs for compliance the responsibility of the contractor. The project includes mandatory prebid meetings and attendance is required for prospective bidders. Accessibility improvements are a critical component across all four buildings, with work required to bring existing conditions into compliance with the 2010 ADA Standards and the 2022 California Building Code Chapter 11B, with specific attention to restroom accessibility, entry routes, drinking fountains, and path of travel requirements.

View the file

Other files

File Type Posted
Bid_Package_10531.pdf PDF
Project_Manual_10531.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROJECT SCOPE

BUILDING # 53 - EDUCATION BUILDING

REMOVAL OF SLOPED WINDOW SYSTEM INCLUDING ATTACHED VERTICAL WINDOW SYSTEM AND REPLACEMENT WITH A VERTICAL STOREFRONT WINDOW SYSTEM WITH ADDITION OF ROOF STRUCTURE AND ROOFING TO ENCLOSE SPACE. REMOVAL OF THE

EXISTING VCT FLOORING AND REPLACE WITH NEW OF SAME TYPE.

ADD INTERIOR LIGHTING A NEW ROOF / CEILING AREA.

REMOVE AND REPLACE KITCHEN CABINETRY.

ACCESSIBILITY IMPROVEMENTS TO ENTRY, COURTYARD AND RESTROOMS.

BUILDING #60 - ADMINISTRATION BUILDING

REMOVAL OF SLOPED WINDOW SYSTEM AT LOBBY. REPLACE WITH A VERTICAL STOREFRONT WINDOW SYSTEM WITH ADDITION OF

ROOF STRUCTURE AND ROOFING TO ENCLOSE THE SPACE

ADD INTERIOR LIGHTING AT NEW ROOF/CEILING AREA.

REPLACE ROOFING SYSTEM.

ACCESSIBILITY IMPROVEMENTS TO THE RESTROOMS.

BUILDING #64 - GYMNASIUM / RECREATION BUILDING

REMOVE PROJECTED WINDOW ASSEMBLY WITH CURVE TOP AND PROJECTED SUPPORT FRAMING AND REPLACE WITH STOREFRONT WINDOW SYSTEM IN EXISTING OPENING. REPLACE / REFINISH EXTERIOR SURFACES AFFECTED.

REMOVE AND REPLACE ROOFING AT BALCONY.

ACCESSIBILITY IMPROVEMENTS TO ENTRY, DRINKING FOUNTAINS, AND RESTROOMS.

BUILDING #66 - POOL BUILDING

REMOVAL AND REPLACEMENT OF DAMAGED INDIVIDUAL GLASS BLOCK UNITS AT NORTH AND SOUTH GLASS BLOCK WINDOW ASSEMBLIES. REPLACE OR RE-INSTALL BACKER AND EXPANSION RODS. RE-POINT ALL GROUT JOINTS. STRIP AND REFINISH ALL

EXPOSED STEEL FRAMES.

PROJECT TEAM

CLIENT:

ALLEN YOUNG

CALIFORNIA DEPARTMENT OF EDUCATION

1430 N STREET, SUITE 1201

SACRAMENTO, CA 95814

EMAIL: ayoung@cde.ca.gov

PROJECT DIRECTOR:

RANDI CHEGWIDDEN

DEPARTMENT OF GENERAL SERVICES

707 3RD STREET , SUITE 4-405

WEST SACRAMENTO, CA 95605

DESIGN TEAM:

ARCHITECT: JAMES MADRIAGO DGS

ARCHITECTURAL

DESIGNER: ELENA KELTGEN DGS

MECHANICAL: DUY NGUYEN DGS

ELECTRICAL: JIPINDER KAUR DGS

STRUCTURAL: ANAND KALINDINDI DGS

CIVIL: JESSICA WALLER DGS

PROJECT LOCATION

500 WALNUT AVENUE

FREMONT, CA 94536

ALAMEDA COUNTY

APPLICABLE CODES

PARTIAL LIST OF APPLICABLE CODES

2022 CALIFORNIA ADMINISTRATIVE CODE (CAC), PART 1, TITLE 24 CCR

2022 CALIFORNIA BUILDING CODE (CBC), PART 2, TITLE 24 CCR

2022 CALIFORNIA ELECTRICAL CODE (CEC), PART 3, TITLE 24 CCR

2022 CALIFORNIA MECHANICAL CODE (CMC), PART 4, TITLE 24 CCR

2022 CALIFORNIA PLUMBING CODE (CPC), PART 5, TITLE 24 CCR

2022 CALIFORNIA ENERGY CODE (CEC), PART 6, TITLE 24 CCR

2022 CALIFORNIA FIRE CODE (CFC), PART 9, TITLE 24 CCR

2022 CALIFORNIA EXISTING BUILDING CODE (CEBC), PART 10, TITLE 24 CCR

2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGREEN), PART 11, TITLE 24 CCR

2022 CALIFORNIA REFERENCED STANDARDS CODE, PART 12, TITLE 24 CCR

TITLE 19 CCR, PUBLIC SAFETY, STATE FIRE MARSHAL REGULATIONS

2019 ASME A17.1/CSA B44-16 SAFETY CODE FOR ELEVATORS AND ESCALATORS

PARTIAL LIST OF APPLICABLE STANDARDS

NFPA 13 STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS (CA AMENDED) -- 2022 EDITION NFPA 14 STANDARD FOR THE INSTALLATION OF STANDPIPE AND HOSE SYSTEMS (CA AMENDED) --2019 EDITION

NFPA 17 STANDARD FOR DRY CHEMICAL EXTINGUISHING SYSTEMS -- 2021 EDITION

NFPA 17A STANDARD FOR WET CHEMICAL EXTINGUISHING SYSTEMS -- 2021 EDITION

NFPA 20 STANDARD FOR THE INSTALLATION OF STATIONARY PUMPS FOR FIRE PROTECTION -- 2019 EDITION

NFPA 22 STANDARD FOR WATER TANKS FOR PRIVATE FIRE PROTECTION -- 2018 EDITION

NFPA 24 STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE MAINS AND THEIR APPURTENANCES (CA AMENDED) -- 2019 EDITION

NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE (CA AMENDED) -- 2022 EDITION

NFPA 80 STANDARD FOR FIRE DOORS AND OTHER OPENING PROTECTIVES - 2019 EDITION

NFPA 2001 STANDARD ON CLEAN AGENT FIRE EXTINGUISHING SYSTEMS (CA AMENDED) - 2018 EDITION UL 300 STANDARD FOR FIRE TESTING OF FIRE EXTINGUISHING SYSTEMS FOR PROTECTION OF COMMERCIAL COOKING EQUIPMENT

-- 2005 (REV. 2014)

UL 464 AUDIBLE SIGNALING DEVICES FOR FIRE ALARM AND SIGNALING SYSTEMS, INCLUDING ACCESSORIES -- 2003 EDITION UL 521 STANDARD FOR HEAT DETECTORS FOR FIRE PROTECTIVE SIGNALING SYSTEMS -- 1999 EDITION ICC 300 STANDARD FOR BLEACHERS, FOLDING AND TELESCOPIC SEATING, AND GRANDSTANDS -- 2017 EDITION

FOR A COMPLETE LIST OF APPLICABLE NFPA STANDARDS REFER TO 2022 CBC (SFM) CHAPTER 35 AND CALIFORNIA FIRE CODE (CFC) CHAPTER 80.

SEE CALIFORNIA BUILDING CODE, CHAPTER 35, FOR STATE OF CALIFORNIA AMENDMENTS TO THE NFPA STANDARDS

AMERICANS WITH DISABILITIES ACT 2010 STANDARDS INCLUDING:

• TITLE II REGULATIONS AT 28 CFR PART 35.151 AND;

• 2004 AMERICANS WITH DISABILITIES ACT ACCESSIBLE GUIDELINES (ADAAG) AT 36 CFR PART 1191 APPENDICES D AND C

WHERE THESE TWO DIFFER, 28 CFR PART 35.151 SHALL PREVAIL

G001

SEQUENCE DESIGNATOR

SUBSET DESIGNATOR

SHEET TYPE DESIGNATOR

DISCIPLINE DESIGNATOR

EXAMPLE:

G - GENERAL

C - CIVIL

A - ARCHITECTURE

S - STRUCTURAL

EXAMPLE:

0 - GENERAL

1 - PLANS

EXAMPLE:

0 - SITE

1 - DEMOLITION

SHEET INDEX LEGEND

2 - FLOOR

# - ETC

2 - ELEVATIONS

# - ETC

M - MECHANICAL

P - PLUMBING

E - ELECTRICAL

X - ETC

ARCHITECT'S STATEMENT

THE PROVIDED, BUT NOT LIMITED TO, CIVIL, PLUMBING, MECHANICAL, FIRE PROTECTION, ELECTRICAL, SECURITY, ELEVATOR MODULAR DRAWINGS, AND SPECIFICATIONS, AND CALCULATIONS HAVE BEEN PREPARED BY OTHER DESIGN PROFESSIONALS OR CONSULTANTS WHO ARE LICENSED AND/OR AUTHORIZED TO PREPARE SUCH DRAWINGS IN THIS STATE. THESE DOCUMENTS HAVE BEEN EXAMINED BY ME FOR THE DESIGN INTENT AND HAVE BEEN FOUND TO MEET THE APPROPRIATE REQUIREMENTS OF TITLE 24, CALIFORNIA CODE OF REGULATIONS AND THE PROJECT SPECIFICATIONS PREPARED BY ME. THE SECTIONS LISTED ABOVE ARE ACCEPTABLE FOR THE INCORPORATION IN TO THIS PROJECT FOR WHICH I AM THE INDIVIDUAL DESIGNATED TO BE IN GENERAL RESPONSIBLE CHARGE (OR FOR WHICH I HAVE BEEN DELEGATED RESPONSIBILITY FOR THE PORTION OF WORK).

SIGNATURE OF ARCHITECT DATE

LICENSE NUMBER EXPIRATION DATE

DEFERRED SUBMITTAL

DIVISION of the STATE ARCHITECT (DSA) NOTES

1. CHANGES TO THE APPROVED DRAWINGS AND SPECIFICATIONS SHALL BE MADE BY AN ADDENDUM OR A CONSTRUCTION CHANGE DOCUMENT (CCD) APPROVED BY THE DIVISION OF THE STATE ARCHITECT, AS REQUIRED BY SECTION 4-338, PART 1, TITLE 24, CCR

2. A DSA ACCEPTED TESTING LABORATORY DIRECTLY EMPLOYED BY THE DISTRICT (OWNER) SHALL CONDUCT ALL THE REQUIRED TESTS AND

INSPECTIONS FOR THE PROJECT.

3. A DSA CERTIFIED PROJECT INSPECTOR EMPLOYED BY THE DISTRICT (OWNER) AND APPROVED BY THE DSA SHALL PROVIDE CONTINUOUS INSPECTION OF THE WORK. THE DUTIES OF THE INSPECTOR ARE DEFINED IN SECTION 4-342, PART 1, TITLE 24, CCR. A MINIMUM CLASS _____

INSPECTOR IS REQUIRED.

4. THE INTENT OF THESE DRAWINGS AND SPECIFICATIONS IS THAT THE WORK OF THE ALTERATION, REHABILITATION, OR RECONSTRUCTION IS TO BE IN ACCORDANCE WITH TITLE 24, CCR. SHOULD ANY EXISTING CONDITIONS SUCH AS DETERIORATION OR NON-COMPLYING CONSTRUCTION BE DISCOVERED WHICH IS NOT COVERED BY TECH CONTRACT DOCUMENTS WHEREIN THE FINISHED WORK WILL NOT COMPLY WITH TITLE 24, CCR, A CONSTRUCTION CHANGE DOCUMENT (CCD), OR A SEPARATE SET OF PLANS AND SPECIFICATIONS DETAILING AND SPECIFYING THE REQUIRED WORK SHALL SUBMITTED TO AND APPROVED BY DSA BEFORE PROCEEDING WITH THE WORK. (SECTION

4-317(C), PART 1, TITLE 24, CCR).

5. SUBSTITUTIONS AFFECTING ITEMS REGULATED BY THE DIVISION OF THE STATE ARCHITECT (DSA) REQUIRE DSA APPROVAL AS AN

ADDENDUM

DSA CERTIFICATION OF THE CURRENT PROJECT 01-122002 IS CONTINGENT UPON THE CERTIFICATION OF

PROJECT 01-120082, WHICH INCLUDES ACCESSIBLE PARKING LOT CSB-4.

GENERAL

G001 COVER SHEET

G101 SITE PLAN

GA021 BLDG 53 CODE REVIEW

GB021 BLDG 60 CODE REVIEW

GC021 BLDG 64 CODE REVIEW

GD021 BLDG 66 CODE REVIEW

CIVIL

C001 GENERAL CIVIL NOTES

C011 DEMOLITION COURTYARD BLDG 53

C101 BLDG 53 SITE PLAN

C530 DETAILS

ARCHITECTURAL

A001 ARCHITECTURAL COVER SHEET

AA101 BLDG 53 - DEMO FLOOR PLAN

AA102 BLDG 53 - DEMO REFLECTED CEILING PLAN

AA111 BLDG 53 - FLOOR PLAN

AA112 BLDG 53 - REFLECTED CEILING PLAN

AA221 BLDG 53 - INTERIOR ELEVATIONS RESTROOM

AA521 BLDG 53 - DEMO EXTERIOR DETAILS

AA522 BLDG 53 - NEW EXTERIOR DETAILS

AB101 BLDG 60 - DEMO FLOOR PLAN

AB102 BLDG 60 - DEMO REFLECTED CEILING PLANS

AB103 BLDG 60 - DEMO ROOF PLAN

AB111 BLDG 60 - FLOOR PLAN

AB112 BLDG 60 - REFLECTED CEILING PLAN

AB113 BLDG 60 - ROOF PLAN

AB221 BLDG 60 - INTERIOR ELEVATIONS RESTROOM

AB521 BLDG 60 - DEMO EXTERIOR DETAILS

AB522 BLDG 60 - NEW EXTERIOR DETAILS

AB523 BLDG 60 - ROOF DETAILS

AC101 BLDG 64 - DEMO FLOOR PLANS

AC102 BLDG 64 - DEMO REFLECTED CEILING PLAN

AC111 BLDG 64 - FLOOR PLANS

AC112 BLDG 64 - REFLECTED CEILING PLANS

AC221 BLDG 64 - INTERIOR ELEVATIONS RESTROOM

AC521 BLDG 64 - DEMO EXTERIOR DETAILS

AC523 BLDG 64 - NEW EXTERIOR DETAILS

AD111 BLDG 66 - FLOOR PLAN

AD521 BLDG 66 - EXTERIOR DETAILS

AD522 BLDG 66 - EXTERIOR DETAILS

A502 ACCESSIBLE PLUMBING AND CASEWORK DETAILS

A503 ACCESSIBLE SIGN DETAILS

A504 ACCESSIBLE MISCELLANEOUS DETAILS

A621 SCHEDULES/ DIAGRAMS DOORS & WINDOWS

STRUCTURAL

S001 GENERAL STRUCTURAL NOTES

S111 BLDG 53 FOUNDATION AND ROOF FRAMING PLAN

S112 BLDG 53 FOUNDATION AND ROOF FRAMING PLAN

S251 BLDG 53 ELEVATION AND DETAILS

S252 BLDG 60 ELEVATION AND DETAILS

SHEET INDEX

Issue

Project

Supervisor Designed Drawn

DSA App No.

Sheet Title

Project Number

Reference North Sheet Scale

Sheet Number

A x

C o p y ri g h t

C a lif o rn ia D e p a rt m e n t o f

G e n e ra l S e rv ic e s

R e a l E s ta te S e rv ic e s D iv is io n

BCDEFGHIJKLMNO

ABCDEFGHIJKLMNO

SFM Permit No.

RELATIVE BORDER SCALE IN INCHES

0 1 2 3

/2

/2

:4 :3

P

M C

P ro je c ts

\0

A

R C

C

E N

T R

A L _J a m e s.

M a d ri a g o .r vt

G001

D.Solomon J.Madriogo E.Keltgen

01-122002

COVER SHEET

000000000010531

SYSTEMS REPAIR

CDE - WINDOW

500 WALNUT AVENUE

FREMONT, CA 94536

ALAMEDA COUNTY

CALIFORNIA DEPARTMENT OF

EDUCATION

CALIFORNIA DEPARTMENT OF EDUCATION

500 WALNUT AVENUE

FREMONT, CA 94536

ALAMEDA COUNTY

WINDOW SYSTEMS REPAIR

PROJECT NUMBER: 000000000010531

N/A

V3

CALIFORNIA SCHOOL FOR THE BLIND

MECHANICAL

M111 DEMOLITION FLOOR PLAN BLDG 53

M121 FLOOR PLAN BLDG 53

PLUMBING

P001 SCHEDULES AND NOTES

P101 DEMOLITION FLOOR PLAN BLDG 53

P102 DEMOLITION FLOOR PLAN BLDG 60

P103 DEMOLITION FLOOR PLAN BLDG 64

P121 FLOOR PLAN BLDG 53

P122 FLOOR PLAN BLDG 60

P123 FLOOR PLAN BLDG 64

P551 DETAILS

ELECTRICAL

E001 ELECTRICAL SYMBOL LIST

E002 ELECTRICAL ABBREVIATIONS AND GENERAL NOTES

EA111 BLDG 53 - FLOOR PLAN

EB111 BLDG 60 - FLOOR PLAN

EC111 BLDG 64 - FLOOR PLAN

E621 PANEL SCHEDULES

Total: 63

C-26064 10-31-27

No. Date Description

1 2/13/26

03-20-26

TEST MARK (For DSA Use Only) Prior to adding document to the Session the Plan Reviewer shall place this test mark off the top edge of the first sheet and change status to "INCORPORATE".

If Back-check menu does not show or the color does not change to green, the Plan Reviewer shall fix the back-check menu. For guidance on how to fix the back-check menu, refer to PR 18-06, Appendix D, Checklist D2.

SIGNATURE OF ARCHITECT DATE

05-05-26

DSA

D E P A R T M E N T O F G E N E R A L S E R V I C E S

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

IDENTIFICATION STAMP

DIV. OF THE STATE ARCHITECT

APP: INC:

REVIEWED FOR

SS FLS ACS

DATE:

4 4 4

01-122002

05/04/2026

ISSUE DATE: JUNE 3, 2026

SHEET LEGEND

EXISTING BUILDINGS

ACCESSIBLE ROUTE

(E) COMPLIANT: DSA 01-120082

BUILDING 53 COURTYARD AREA OF WORK

BUILDINGS IN THIS PROJECT (53, 60, 64, 66)

ACCESSIBLE ROUTE

(E) NON-COMPLIANT - TO REMAIN NON-COMPLIANT

EXISTING FIRE HYDRANTSFH

SITE BOUNDARIES - SCHOOL FOR THE BLIND

BS

EXISTING ACCESSIBLE TOW-AWAY SIGN

(E) COMPLIANT: DSA 01-120082

EXISTING BUS STOP SIGN

(E) COMPLIANT: DSA 01-120082

RESTROOMS (BUILDING 66)

NON-COMPLIANT - TO REMAIN NON-COMPLIANT

REST`ROOMS (BLDG 53, 60, 64)

(E) NON-COMPLIANT, TO BE BROUGHT INTO COMPLIANCE

UNDER THIS PROJECT

TA

ACCESSIBLE ROUTE

(E) NON-COMPLIANT: TO BE BROUGHT INTO COMPLIANCE UNDER

THIS PROJECT

EXISTING FIRE ACCESS ROUTE

EXISTING APPROVED FIRE LANES WERE NOT ABLE TO BE CONFIRMED

FOR THIS PROJECT. FUTURE BUILDING CONSTRUCTION PROJECTS ON

CAMPUS WILL ADDRESS THE APPLICABLE FIRE LANE REQUIREMENTS

PER THE FIRE CODE AND TITLE 19.

ACCESSIBLE ROUTE

(E) COMPLIANT: NO DSA # - TO BE REVIEWED UNDER THIS PROJECT

PHYS ED POOL

BLDG #66

PHYS ED GYM

BLDG #64

AUDITORIUM /

THEATER BLDG #68

ED BLDG

#56

KITCHEN /

DINING BLDG #62

HEALTH

SERVICE BLDG

#63

ADMIN BLDG #60

CLASSROOM

BLDG #58

DIAGNOSTIC

CENTER NORTH

BLDG #51

CLASSROOM

BLDG #52

CLASSROOM

BLDG #53

CLASSROOM

BLDG #54

CLASSROOM

BLDG #55

W A

L N

U T

A V

E N

U E

GALLAUDET DRIVE

LIBRARY #57

AB101

AA111

AC111

AD111

CSB-4 PARKING CALCULATION

USER GROUP: EMPLOYEES AND VISITORS

TOTAL PARKING SPACES: 50

REQUIRED ACCESSIBLE

PARKING

(PER TABLE 11B-208.2): 3

ACCESSIBLE PARKING:

1 STANDARD, 2 VAN

CSB-3 PARKING CALCULATION

USER GROUP: EMPLOYEES AND VISITORS

TOTAL PARKING SPACES: 45

REQUIRED ACCESSIBLE PARKING

(PER TABLE 11B-208.2): 2

ACCESSIBLE PARKING: 2 STANDARD, 2 VAN

CSB-2 PARKING CALCULATION

USER GROUP: EMPLOYEES AND

VISITORS

TOTAL PARKING SPACES: 13

REQUIRED ACCESSIBLE

PARKING

(PER TABLE 11B-208.2): 1

ACCESSIBLE PARKING: 1

STANDARD, 1 VAN

CSB-1 PARKING CALCULATION

USER GROUP: EMPLOYEES AND

VISITORS

TOTAL PARKING SPACES: 21

REQUIRED ACCESSIBLE

PARKING

(PER TABLE 11B-208.2): 1

ACCESSIBLE PARKING: 1 VAN

SPACE

CSB-5 PARKING CALCULATION

USER GROUP: EMPLOYEES

TOTAL PARKING SPACES: 7

REQUIRED ACCESSIBLE PARKING

(PER TABLE 11B-208.2): X

ACCESSIBLE PARKING: 0

CSB-6 PARKING CALCULATION

USER GROUP: EMPLOYEES AND VISITORS

TOTAL PARKING SPACES: 7

REQUIRED ACCESSIBLE PARKING

(PER TABLE 11B-208.2): 1

ACCESSIBLE PARKING: 1

FH

FH

FH

FH

FH

FH

FH

FH

FH

FH

FH

MEN/BOYS - WOMEN/GIRLS RESTROOMS

DRINKING FOUNTAIN

(E) NON-COMPLIANT - TO BE BROUGHT

INTO COMPLIANCE UNDER THIS PROJECT

TA

MEN/BOYS - WOMEN/GIRLS

RESTROOMS, (E) NON-

COMPLIANT - TO REMAIN NON-

COMPLIANT

TA

MAINT

SHOP #

WHSE-

TRANS

CSB-1

CSB-2

CSB-3

CSB-4

CSB-5

CSB-6

MEN/WOMEN RESTROOMS

(E) NON-COMPLIANT - TO BE BROUGHT

INTO COMPLIANCE UNDER THIS PROJECT

MEN/WOMEN RESTROOMS

(E) NON-COMPLIANT - TO BE

BROUGHT INTO COMPLIANCE

UNDER THIS PROJECT

ACCESS TO PUBLIC

RIGHT-OF-WAY

(E) BUS

STOP

CITY BUS

STOP SIGN

(E) BUS

LOADING

AREA

BS

NON-CERTIFIED

NON-CERTIFIED

DSA 01-120082

(E) ACCESSBILE PARKING

DSA 01-120082

(E) ACCESSBILE PARKING

DSA 01-120082

(E) ACCESSBILE PARKING

DSA 01-120082

(E) CURB RAMP AND

DETECTABLE WARNINGS

DSA 01-120082

ACCESSIBILITY NOTES

ACCESSIBLE PATH OF TRAVEL:

ACCESSIBLE PATH OF TRAVEL AS INDICATED ON PLANS IS A BARRIER FREE

ACCESS ROUTE WITHOUT ANY ABRUPT LEVEL CHANGES EXCEEDING 1/2" IF

BEVELED AT 1:2 MAXIMUM SLOPE OR VERTICAL LEVEL CHANGES NOT EXCEEDING

1/4" MAXIMUM AND AT LEAST 48" IN WIDTH. SURFACE IS STABLE, FIRM AND SLIP

RESISTANT. CROSS SLOPE DOES NOT EXCEED 2% AND SLOPE IN THE DIRECTION

OF TRAVEL IS LESS THAN 5% UNLESS OTHERWISE INDICATED. ACCESSIBLE PATH

OF TRAVEL SHALL BE MAINTAINED FREE OF OVERHANGING OBSTRUCTIONS TO

80" MINIMUM AND PROTRUDING OBJECTS GREATER THAN 4" PROJECTION FROM

WALL ABOVE 27" AND LESS THAN 80". ARCHITECT SHALL VERIFY THAT THERE ARE

NO BARRIERS IN THE PATH OF TRAVEL.

DESIGN PROFESSIONAL IN GENERAL RESPONSIBLE CHARGE STATEMENT:

THE POT IDENTIFIED IN THESE CONSTRUCTION DOCUMENTS IS COMPLIANT WITH

CURRENT APPLICABLE CALIFORNIA BUILDING CODE ACCESSIBILITY PROVISIONS

FOR PATH OF TRAVEL REQUIREMENTS FOR ALTERATIONS AND STRUCTURAL

REPAIRS. AS PART OF THE DESIGN OF THIS PROJECT, THE POT WAS EXAMINED

AND ANY ELEMENTS, COMPONENTS OR PORTION OF THE POT THAT WERE

DETERMINED TO BE NONCOMPLIANT 1) HAVE BEEN IDENTIFIED AND 2) THE

CORRECTIVE WORK NECESSARY TO BRING THEM INTO COMPLIANCE HAS BEEN

INCLUDED WITHIN THE SCOPE OF THIS PROJECT'S WORK THROUGH DETAILS,

DRAWINGS AND SPECIFICATIONS INCORPORATED INTO THESE CONSTRUCTION

DOCUMENTS. ANY NONCOMPLIANT ELEMENTS, COMPONENTS OR PORTION OF

THE POT THAT WILL NOT BE CORRECTED BY THIS PROJECT BASED A FINDING OF

UNREASONABLE HARDSHIP ARE SO INDICATED IN THESE CONSTRUCTION

DOCUMENTS.

DURING CONSTRUCTION, IF POT ITEMS WITHIN THE SCOPE OF THE PROJECT

REPRESENTED AS CODE COMPLIANT ARE FOUND TO BE NONCONFORMING, THEY

SHALL BE BROUGHT INTO COMPLIANCE WITH THE CBC AS A PART OF THIS

PROJECT BY MEANS OF A CONSTRUCTION CHANGE DOCUMENT.

DSA CERTIFICATION OF THE CURRENT PROJECT 01-122002 IS CONTINGENT UPON

THE CERTIFICATION OF PROJECT 01-120082, WHICH INCLUDES ACCESSIBLE

PARKING AT PARKING LOT CSB-4.

1. ALL SITE PLAN ELEMENTS SHOWN ARE EXISTING TO REMAIN

UNLESS OTHERWISE NOTED.

2. FIRE SAFETY DURING CONSTRUCTION & DEMOLITION WILL BE

ENFORCED IN ACCORDANCE WITH CBC & CFC CHAPTER 33.

3. GRADING PLANS, DRAINAGE IMPROVEMENTS, ROAD AND ACCESS

REQUIREMENTS AND ENVIRONMENTAL HEALTH CONSIDERATIONS

SHALL COMPLY WITH ALL LOCAL ORDINANCES.

GENERAL NOTES

Issue

Project

Supervisor Designed Drawn

DSA App No.

Sheet Title

Project Number

Sheet Scale

Sheet Number

A x

C o p y ri g h t

C a lif o rn ia D e p a rt m e n t o f

G e n e ra l S e rv ic e s

R e a l E s ta te S e rv ic e s D iv is io n

BCDEFGHIJKLMNO

ABCDEFGHIJKLMNO

SFM Permit No.

RELATIVE BORDER SCALE IN INCHES

0 1 2 3

/3

/2

:0

:4 P

M C

P ro je c ts

\0

A

R C

C

E N

T R

A L J a m e s .M a d ri a g o

.r vt

G101

D.Solomon J.Madriogo E.Keltgen

01-122002

SITE PLAN

000000000010531

1"=50'-0"

SYSTEMS REPAIR

CDE - WINDOW

500 WALNUT AVENUE

FREMONT, CA 94536

ALAMEDA COUNTY

CALIFORNIA DEPARTMENT OF

EDUCATION

N/A

V3

1" = 50'-0"1 SITE PLAN

N

No. Date Description

1 2/13/26

04-30-26

DSA

D E P A R T M E N T O F G E N E R A L S E R V I C E S

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

IDENTIFICATION STAMP

DIV. OF THE STATE ARCHITECT

APP: INC:

REVIEWED FOR

SS FLS ACS

DATE:

4 4 4

01-122002

ROOM

NAME

ROOM NUMBER

ROOM AREA

OCCUPANT LOAD FACTOR

TOTAL OCCUPANTS

1/100

FUNCTION OF SPACEBUSINESS

OCC MAXIMUM EXITING OCCUPANTS

RW REQUIRED OPENING WIDTH

AW ACTUAL OPENING WIDTH

EXIT LOCATION AND NUMBER OF

OCCUPANTS USING EXIT

PATH OF TRAVEL TO EXIT

FIRE EXTINGUISHER /

FIRE EXTINGUISHER CABINET *

FIRE LIFE SAFETY LEGEND

EXISTING WALL

AREA OF WORK

EXISTING 1 HOUR WALL

NONSTRUCTURAL PROVISIONS

OCCUPANCY GROUPS AND VARIED USES:E,A

BUILDING CONSTRUCTION TYPE:V

NUMBER OF STORIES:1

ACTUAL BUILDING HEIGHT:16'-0"

BUILDING AREA IN SQUARE FEET:7,285

AREA OF PROJECT IN SQUARE FEET:460

SEPARATED, NON-SEPARATED, ACCESSORY USE:NON-SEPARATED

ALLOWABLE AREA:NA

AREA INCREASE:NONE

HEIGHT INCREASE: NONE

FIRE SPRINKLERS (TYPE, FULL, PARTIAL):NO

FIRE ALARM (TYPE):YES

OTHER FIRE PROTECTION SYSTEM (TYPE):NO

SMOKE CONTROL SYSTEM (Y/N):NO

OCCUPANT LOAD FOR ENTIRE BUILDING AND EACH FLOOR:384

YEAR BUILDING WAS CONSTRUCTED:1978

HIGH FIRE HAZARD SEVERITY ZONE (Y/N):NO

SEISMIC JOINTS AND LOCATIONS:NA

EMERGENCY RESPONDER RADIO COVERAGE (Y/N):YES

BUILDING INFORMATION

G

G

K

K

TESTING

RM.

1/150

PSYCH.

OFFICE

1/150

EDUC.

COOR.

1/150

CLERICAL

AREA

1/150

PRINC.

OFFICE

1/150

OFFICE

1/150

STAFF

REPR.

1/15

WORK

ROOM

1/15

HALL

WOMEN

TOILET

MEN TOILET

STORAGE

1/300

STAFF

LOUNGE

1/15

MECH.

ROOM

1/300

LOCKABLE

STOR.

1/15

STORAGE

1/300

LAUNDRY

1/300

TOILET

INSTR. UNIT

1/15

PROJ.

ROOM

1/150

INSTR. UNIT

1/15

STORAGE

1/300

STORAGE

1/300

STORAGE

1/300

STORAGE

1/300

STORAGE

1/300

STUDY

ROOM

1/50

JAN

1/300

FOOD

SKILLS

1/15

HOME/CRAFT/CENTER

1/50

STOR.

1/300

STOR.

1/300

STAFF

KITCH.

1/15

STOR

1/300

TEACHER

ROOM

1/150

42+13+1+11+1+1=69/2=35

52+1+1+1=55/2=23

58+1+1+1+2=63/2=32

49+1+9=59/2=30

EXIT 3

OCC = 30

RW = 6"

AW = 40"

EXIT 1

OCC = 9

RW = 1.8"

AW = 40"

EXIT 2

OCC = 35

RW = 7"

AW = 40"

EXIT 4

OCC = 32

RW = 6.4"

AW = 40"

EXIT 5

OCC = 23

RW = 4.6"

AW = 40"

EXIT 6

OCC = 23

RW = 4.6"

AW = 40"

EXIT 8

OCC = 35

RW = 7"

AW = 40"

EXIT 9

OCC = 35

RW = 7"

AW = 36"

EXIT 10

OCC = 30

RW = 6"

AW = 40"

EXIT 7

OCC = 32

RW = 6.4"

AW = 36"

26+8+1=35

AA101

AA111

AA102

AA112

DFP

FP

DRCP

RCP

KEYPLAN

N

Issue

Project

Supervisor Designed Drawn

DSA App No.

Sheet Title

Project Number

Sheet Scale

Sheet Number

A x

C o p y ri g h t

C a lif o rn ia D e p a rt m e n t o f

G e n e ra l S e rv ic e s

R e a l E s ta te S e rv ic e s D iv is io n

BCDEFGHIJKLMNO

ABCDEFGHIJKLMNO

SFM Permit No.

RELATIVE BORDER SCALE IN INCHES

0 1 2 3

/2

/2

:4 :3

P

M C

P ro je c ts

\0

A

R C

C

E N

T R

A L _J a m e s.

M a d ri a g o .r vt

GA021

D.Solomon J.Madriogo E.Keltgen

01-122002

BLDG 53 CODE

REVIEW

000000000010531

SYSTEMS REPAIR

CDE - WINDOW

500 WALNUT AVENUE

FREMONT, CA 94536

ALAMEDA COUNTY

CALIFORNIA DEPARTMENT OF

EDUCATION

N/A

V3

1/4" = 1'-0"1 BLDG 53 EXITING FLOOR PLAN

N

No. Date Description

1 2/13/26

03-20-26

DSA

D E P A R T M E N T O F G E N E R A L S E R V I C E S

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

IDENTIFICATION STAMP

DIV. OF THE STATE ARCHITECT

APP: INC:

REVIEWED FOR

SS FLS ACS

DATE:

4 4 4

01-122002

ROOM NUMBER

ROOM AREA

OCCUPANT LOAD FACTOR

TOTAL OCCUPANTS

1/100

FUNCTION OF SPACEBUSINESS

OCC MAXIMUM EXITING OCCUPANTS

RW REQUIRED OPENING WIDTH

AW ACTUAL OPENING WIDTH

EXIT LOCATION AND NUMBER OF

OCCUPANTS USING EXIT

PATH OF TRAVEL TO EXIT

FIRE EXTINGUISHER /

FIRE EXTINGUISHER CABINET *

FIRE LIFE SAFETY LEGEND

EXISTING WALL

AREA OF WORK

EXISTING 1 HOUR WALL

ADMINISTRATIVE

SUPPORT

AREAS

AD-6

1/150

REPROD

CENTER

AD-7

1/15

BUSINESS

MANGR

AD-12

1/150

PERSONNEL

OFFICE

AD-14

1/150

FILE/ STOR/

MAIL

AD-8

1/300

WOMEN

AD-3.2

MEN

AD-3.1

ORIENTATION/

CONFERENCE

AD-4

1/15

ADMIN.

SUPPORT

AD-6.7

1/150

SUPERINTENDENT

OFFICE

AD-10

1/150

VEST

AD-2A

ACCOUNTING

OFFICE

AD-13

1/150

N

NJ

J

LOBBY/

DISPLAY

AREA

AD-2

1/15

RECEPTION

AREA

AD-1

1/150

1+5+10+1+1+1=19

10+39+1+21+1+2=74

EXIT 1

OCC =25

RW = 5"

AW = 72"

EXIT 2

OCC =25

RW = 5"

AW = 40"EXIT 3

OCC =25

RW = 5"

AW = 40"

EXIT 4

OCC =25

RW = 5"

AW = 40"

KEYPLAN

N

NONSTRUCTURAL PROVISIONS

OCCUPANCY GROUPS AND VARIED USES:A

BUILDING CONSTRUCTION TYPE:V

NUMBER OF STORIES:1

ACTUAL BUILDING HEIGHT:20'-0"

BUILDING AREA IN SQUARE FEET:3,012

AREA OF PROJECT IN SQUARE FEET:528

SEPARATED, NON-SEPARATED, ACCESSORY USE:NON-SEPARATED

ALLOWABLE AREA:NA

AREA INCREASE:NONE

HEIGHT INCREASE: NONE

FIRE SPRINKLERS (TYPE, FULL, PARTIAL):NO

FIRE ALARM (TYPE):YES

OTHER FIRE PROTECTION SYSTEM (TYPE):NO

SMOKE CONTROL SYSTEM (Y/N):NO

OCCUPANT LOAD FOR ENTIRE BUILDING AND EACH FLOOR:85

YEAR BUILDING WAS CONSTRUCTED:1978

HIGH FIRE HAZARD SEVERITY ZONE (Y/N):NO

SEISMIC JOINTS AND LOCATIONS:NA

EMERGENCY RESPONDER RADIO COVERAGE (Y/N):YES

BUILDING INFORMATION

Issue

Project

Supervisor Designed Drawn

DSA App No.

Sheet Title

Project Number

Sheet Scale

Sheet Number

A x

C o p y ri g h t

C a lif o rn ia D e p a rt m e n t o f

G e n e ra l S e rv ic e s

R e a l E s ta te S e rv ic e s D iv is io n

BCDEFGHIJKLMNO

ABCDEFGHIJKLMNO

SFM Permit No.

RELATIVE BORDER SCALE IN INCHES

0 1 2 3

/2

/2

:4 :3

P

M C

P ro je c ts

\0

A

R C

C

E N

T R

A L _J a m e s.

M a d ri a g o .r vt

GB021

D.Solomon J.Madriogo E.Keltgen

01-122002

BLDG 60 CODE

REVIEW

000000000010531

1/8"=1'-0"

SYSTEMS REPAIR

CDE - WINDOW

500 WALNUT AVENUE

FREMONT, CA 94536

ALAMEDA COUNTY

CALIFORNIA DEPARTMENT OF

EDUCATION

N/A

V3

1/8" = 1'-0"1 BLDG 60 EXITING FLOOR PLAN

N

No. Date Description

1 2/13/26

03-20-26

DSA

D E P A R T M E N T O F G E N E R A L S E R V I C E S

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

IDENTIFICATION STAMP

DIV. OF THE STATE ARCHITECT

APP: INC:

REVIEWED FOR

SS FLS ACS

DATE:

4 4 4

01-122002

H

H

K.1

K.1

M

M

18.1 18.1

20.920.9

21 21

MULTI-PURPOSE

RE-3

1/15

LOUNGE

RE-1

1/15

KITCHEN

RE-2

1/15

CORR.

RE-9.1

CLUB ROOM

RE-7

1/15

MEN

RE-5160

WOMEN

RE-6

JAN

RE-4

1/300

STORAGE

RE-8

1/300

MECH

ROOM

RE-16

1/300

STORAGE

RE-15

1/300

STORAGE

RE-14

1/300

CENTRAL

ACTIVIES

RE-10

1/15

STORAGE

RE-12

1/300

STORAGE

RE-11

1/300

STORAGE

RE-13

1/300

13 45+13+14+10=82/3=27

27+72+2+1=102284+1+1=286/4=72

EXIT 1

OCC = 102

RW = 20.4"

AW = 40"

EXIT 2

OCC = 27

RW = 5.4"

AW = 72"

EXIT 3

OCC = 27

RW = 5.4"

AW = 40"

EXIT 4

OCC = 13

RW = 2.6"

AW = 40"

EXIT 5

OCC = 72

RW = 14.4"

AW = 72"

EXIT 6

OCC = 72

RW = 14.4"

AW = 72"

EXIT 7

OCC = 72

RW = 14.4"

AW = 40"

K.1 M

18.1

LOFT

LOFT

1/15

LOFT FLOOR PLAN

AC101

AC101

AC102

DFP

DRCP

AC111

FP

AC112

RCP

AC102

DRCP

AC111

FP

AC112

RCP

DFP

OPEN BELOW

OPEN

BELOW

OPEN

BELOW

ROOM

NAME

ROOM NUMBER

ROOM AREA

OCCUPANT LOAD FACTOR

TOTAL OCCUPANTS

1/100

FUNCTION OF SPACEBUSINESS

OCC MAXIMUM EXITING OCCUPANTS

RW REQUIRED OPENING WIDTH

AW ACTUAL OPENING WIDTH

EXIT LOCATION AND NUMBER OF

OCCUPANTS USING EXIT

PATH OF TRAVEL TO EXIT

FIRE EXTINGUISHER /

FIRE EXTINGUISHER CABINET *

FIRE LIFE SAFETY LEGEND

EXISTING WALL

AREA OF WORK

EXISTING 1 HOUR WALL

KEYPLAN

N

NONSTRUCTURAL PROVISIONS

OCCUPANCY GROUPS AND VARIED USES:A

BUILDING CONSTRUCTION TYPE:V

NUMBER OF STORIES:1& LOFT

ACTUAL BUILDING HEIGHT:30'-0"

BUILDING AREA IN SQUARE FEET:7,810

AREA OF PROJECT IN SQUARE FEET:350

SEPARATED, NON-SEPARATED, ACCESSORY USE:NON-SEPARATED

ALLOWABLE AREA:NA

AREA INCREASE:NONE

HEIGHT INCREASE: NONE

FIRE SPRINKLERS (TYPE, FULL, PARTIAL):NO

FIRE ALARM (TYPE):YES

OTHER FIRE PROTECTION SYSTEM (TYPE):NO

SMOKE CONTROL SYSTEM (Y/N):NO

OCCUPANT LOAD FOR ENTIRE BUILDING AND EACH FLOOR:390

YEAR BUILDING WAS CONSTRUCTED:1978

HIGH FIRE HAZARD SEVERITY ZONE (Y/N):NO

SEISMIC JOINTS AND LOCATIONS:NA

EMERGENCY RESPONDER RADIO COVERAGE (Y/N):YES

BUILDING INFORMATION

Issue

Project

Supervisor Designed Drawn

DSA App No.

Sheet Title

Project Number

Sheet Scale

Sheet Number

A x

C o p y ri g h t

C a lif o rn ia D e p a rt m e n t o f

G e n e ra l S e rv ic e s

R e a l E s ta te S e rv ic e s D iv is io n

BCDEFGHIJKLMNO

ABCDEFGHIJKLMNO

SFM Permit No.

RELATIVE BORDER SCALE IN INCHES

0 1 2 3

/2

/2

:4 :3

P

M C

P ro je c ts

\0

A

R C

C

E N

T R

A L _J a m e s.

M a d ri a g o .r vt

GC021

D.Solomon J.Madriogo E.Keltgen

01-122002

BLDG 64 CODE

REVIEW

000000000010531

1/8"=1'-0"

SYSTEMS REPAIR

CDE - WINDOW

500 WALNUT AVENUE

FREMONT, CA 94536

ALAMEDA COUNTY

CALIFORNIA DEPARTMENT OF

EDUCATION

N/A

V3

1/8" = 1'-0"1 BLDG 64 FLOOR AND LOFT FLOOR PLANS

N

No. Date Description

1 2/13/26

03-20-26

DSA

D E P A R T M E N T O F G E N E R A L S E R V I C E S

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

IDENTIFICATION STAMP

DIV. OF THE STATE ARCHITECT

APP: INC:

REVIEWED FOR

SS FLS ACS

DATE:

4 4 4

01-122002

ROOM NUMBER

ROOM AREA

OCCUPANT LOAD FACTOR

TOTAL OCCUPANTS

1/100

FUNCTION OF SPACEBUSINESS

OCC MAXIMUM EXITING OCCUPANTS

RW REQUIRED OPENING WIDTH

AW ACTUAL OPENING WIDTH

EXIT LOCATION AND NUMBER OF

OCCUPANTS USING EXIT

PATH OF TRAVEL TO EXIT

FIRE EXTINGUISHER /

FIRE EXTINGUISHER CABINET *

FIRE LIFE SAFETY LEGEND

EXISTING WALL

AREA OF WORK

EXISTING 1 HOUR WALL

KEYPLAN

N

18.1 18.1

20 20

F

F A.1

A.1

BOY'S

LOCKERS

PE-4

1/15

HALL

PE-4

BOYS

SHOWERS

PE-5

BOYS

TOILET

PE-3

JANITOR

PE-2

1/300

GIRLS

TOILET

PE-7

GIRLS

SHOWERS

PE-6

GIRLS

LOCKERS

PE-8

1/15

HALL

PE-9

CORRIDOR

PE-1

STORAGE

PE-10

1/300

INSTRUCTOR

PE-11

1/150

FIRST AID

PE-12

1/150

INSTRUCTOR

PE-13

1/150

POOL ROOM

PE-14

1/15

MECH RM

PE-15

1/300

POOL

EQUIP. RM.

PE-16

1/300

STOR

PE-17

1/300

SWIMMING POOL

WADING POOL

EXIT 2

OCC =156

RW = 31.2"

AW = 72"

EXIT 1

OCC =17

RW = 3.4"

AW = 40"

EXIT 5

OCC =17

RW = 3.4"

AW = 40"

EXIT 3

OCC =156

RW = 31.2"

AW = 40"

EXIT 4

OCC = 4

RW = 0.8"

AW = 72"

LxW/25=84

LxW/25=4

29/2=1529/2=15

15+1+1=17 15+1+1=17

15 15

277+15+15+4=311/2=156

SEPARATION WALL

NONSTRUCTURAL PROVISIONS

OCCUPANCY GROUPS AND VARIED USES:A

BUILDING CONSTRUCTION TYPE:V

NUMBER OF STORIES:1

ACTUAL BUILDING HEIGHT:25'-0"

BUILDING AREA IN SQUARE FEET:7,424

AREA OF PROJECT IN SQUARE FEET:100

SEPARATED, NON-SEPARATED, ACCESSORY USE:NON-SEPARATED

ALLOWABLE AREA:NA

AREA INCREASE:NONE

HEIGHT INCREASE: NONE

FIRE SPRINKLERS (TYPE, FULL, PARTIAL):NO

FIRE ALARM (TYPE):YES

OTHER FIRE PROTECTION SYSTEM (TYPE):NO

SMOKE CONTROL SYSTEM (Y/N):NO

OCCUPANT LOAD FOR ENTIRE BUILDING AND EACH FLOOR:351

YEAR BUILDING WAS CONSTRUCTED:1978

HIGH FIRE HAZARD SEVERITY ZONE (Y/N):NO

SEISMIC JOINTS AND LOCATIONS:NA

EMERGENCY RESPONDER RADIO COVERAGE (Y/N):YES

BUILDING INFORMATION

Issue

Project

Supervisor Designed Drawn

DSA App No.

Sheet Title

Project Number

Sheet Scale

Sheet Number

A x

C o p y ri g h t

C a lif o rn ia D e p a rt m e n t o f

G e n e ra l S e rv ic e s

R e a l E s ta te S e rv ic e s D iv is io n

BCDEFGHIJKLMNO

ABCDEFGHIJKLMNO

SFM Permit No.

RELATIVE BORDER SCALE IN INCHES

0 1 2 3

/2

/2

:5 :5

P

M C

P ro je c ts

\0

A

R C

C

E N

T R

A L _J a m e s.

M a d ri a g o .r vt

GD021

D.Solomon J.Madriogo E.Keltgen

01-122002

BLDG 66 CODE

REVIEW

000000000010531

1/8"=1'-0"

SYSTEMS REPAIR

CDE - WINDOW

500 WALNUT AVENUE

FREMONT, CA 94536

ALAMEDA COUNTY

CALIFORNIA DEPARTMENT OF

EDUCATION

N/A

V3

1/8" = 1'-0"1 BLDG 66 EXITING FLOOR PLAN

GLASS BLOCK (WINDOW) REPAIR ONLY.

NOT BUILDING ALTERATION

N

No. Date Description

1 2/13/26

03-20-26

DSA

D E P A R T M E N T O F G E N E R A L S E R V I C E S

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

IDENTIFICATION STAMP

DIV. OF THE STATE ARCHITECT

APP: INC:

REVIEWED FOR

SS FLS ACS

DATE:

4 4 4

01-122002

CIVIL PLAN ABBREVIATIONS

REFERENCE

CIVIL SYMBOL LEGENDS CIVIL GENERAL NOTES

DEMOLITION NOTES

TOPOGRAPHIC SURVEY LEGEND

X 115.73

C

AD

F ile

: X :\P ro je ct s\ xx xx \0

1\ D

W G

\P

LT

\C

G

EN

ER

AL

C

IV

IL

N O

TE

S.

dw g

P lo t D at e:

J an

3,

- 1 0:

am

Pl ot te d by

: j w al le r

V2

707 Third Street, Suite 4-105

Architecture & Engineering Sections

Project Management & Development Branch Real Estate Services Division

State of California

West Sacramento, California 95605

Department of General Services

C op yr ig ht

0, C al ifo rn ia

D ep ar tm en t o f G en er al

S er vi ce s

- R ea l E st at e Se rv ic es D iv is io n

FREMONT, CA 94536

CALIFORNIA DEPARTMENT OF

500 WALNUT AVENUE

CDE - WINDOW

SYSTEMS REPAIR

ALAMEDA COUNTY

000000000010531

01-122002 -

EDUCATION

J.WALLERJ.WALLERJ.DIGIORGIO

GENERAL

CIVIL NOTES

C001

01/13/2026

02/13/26

V3

DSA

D E P A R T M E N T O F G E N E R A L S E R V I C E S

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

IDENTIFICATION STAMP

DIV. OF THE STATE ARCHITECT

APP: INC:

REVIEWED FOR

SS FLS ACS

DATE:

4 4 4

01-122002

BLDG. #53

BLDG. #52

C

AD

F ile

: X :\P ro je ct s\ xx xx \0

1\ D

W G

\P

LT

\C

BL

D G

D

EM

O .d w g

P lo t D at e:

J an

3,

- 1 0:

te d by

: j w al le r

V2

707 Third Street, Suite 4-105

Architecture & Engineering Sections

Project Management & Development Branch Real Estate Services Division

State of California

West Sacramento, California 95605

Department of General Services

C op yr ig ht

0, C al ifo rn ia

D ep ar tm en t o f G en er al

S er vi ce s

- R ea l E st at e Se rv ic es D iv is io n

FREMONT, CA 94536

CALIFORNIA DEPARTMENT OF

500 WALNUT AVENUE

CDE - WINDOW

SYSTEMS REPAIR

ALAMEDA COUNTY

000000000010531

01-122002 -

EDUCATION

J.WALLERJ.WALLERJ.DIGIORGIO

DEMOLITION

COURTYARD

BLDG. 53

1" = 5'-0"

C011

EXISTING CONCRETE

EXISTING CONCRETE TO BE REMOVED

EXISTING PAVERS TO BE REMOVED

FIRE LANE DGS PROJECT NO. 005072,

DSA APP NO. 01-120082

SAW CUT LINE

KEY PLAN

KEY NOTES

LEGEND

COURTYARD PLAN VIEW

1. REMOVE PAVERS

2. SAW CUT CONCRETE PAVING

3. REMOVE CONCRETE PAVING

4. SALVAGE EXISTING PICNIC TABLE AND SAVE ON

SITE WITH DIRECTIONS FROM THE FACILITY

OWNER.

5. PROTECT EXISTING PLANTS AND IRRIGATION.

6. PROTECT TREE AND CUT TREE ROOTS AS

NEEDED PER ARBORIST RECOMMENDATIONS.

01/13/2026

02/13/26

V3

DSA

D E P A R T M E N T O F G E N E R A L S E R V I C E S

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

IDENTIFICATION STAMP

DIV. OF THE STATE ARCHITECT

APP: INC:

REVIEWED FOR

SS FLS ACS

DATE:

4 4 4

01-122002

BLDG. #53

BLDG. #52

TYP.

TYP.

C

AD

F ile

: X :\P ro je ct s\ xx xx \0

1\ D

W G

\P

LT

\C

SI

TE

P

AL

N

BL

D G

3.

dw g

P lo t D at e:

J an

3,

- 1 0:

te d by

: j w al le r

V2

707 Third Street, Suite 4-105

Architecture & Engineering Sections

Project Management & Development Branch Real Estate Services Division

State of California

West Sacramento, California 95605

Department of General Services

C op yr ig ht

0, C al ifo rn ia

D ep ar tm en t o f G en er al

S er vi ce s

- R ea l E st at e Se rv ic es D iv is io n

FREMONT, CA 94536

CALIFORNIA DEPARTMENT OF

500 WALNUT AVENUE

CDE - WINDOW

SYSTEMS REPAIR

ALAMEDA COUNTY

000000000010531

01-122002 -

EDUCATION

J.WALLERJ.WALLERJ.DIGIORGIO

BLDG #53

SITE PLAN

1" = 5'-0"

C101COURTYARD PLAN VIEW

EXISTING CONCRETE

NEW CONCRETE

EXISTING LANDSCAPING

FIRE LANE PROJECT DGS No. 05072

DSA APP. 01-12082

ACCESSIBLE ROUTE (AR)

KEY PLAN

LEGEND

KEY NOTES

1. INSTALL NEW CONCRETE PAVING PER

2. INSTALL CONCRETE JOINTS PER

3. CONTRACTOR TO HIRE CERTIFIED CA ARBORIST

TO ASSES TREE HEALTH AND PROVIDE DESIGN

RECOMMENDATIONS TO ALTER HARDSCAPE FOR

TREE TO REMAIN IN PLACE.

4. RAISE SOIL BED TO 1" BELOW CONCRETE

GRADE. REPLACE PLANTS AS NEEDED PER

DIRECTION OF THE STATE.

5. MULCH EXISTING LANDSCAPE.

01/13/2026

02/13/26

V3

DSA

D E P A R T M E N T O F G E N E R A L S E R V I C E S

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

IDENTIFICATION STAMP

DIV. OF THE STATE ARCHITECT

APP: INC:

REVIEWED FOR

SS FLS ACS

DATE:

4 4 4

01-122002

C02_CG09

CONCRETE SIDEWALK

TYPICAL CONCRETE JOINTS

C

AD

F ile

: X :\P ro je ct s\ xx xx \0

1\ D

W G

\P

LT

\C

D

ET

AI

LS

BL

D

G

3.

dw g P lo t D at e:

J an

3,

- 1

0:

te d by : j w al le r

V2

707 Third Street, Suite 4-105

Architecture & Engineering Sections

Project Management & Development Branch Real Estate Services Division

State of California

West Sacramento, California 95605

Department of General Services

C op yr ig ht

0, C al ifo rn ia

D ep ar tm en t o f G en er al

S er vi ce s

- R ea l E st at e Se rv ic es D iv is io n

FREMONT, CA 94536

CALIFORNIA DEPARTMENT OF

500 WALNUT AVENUE

CDE - WINDOW

SYSTEMS REPAIR

ALAMEDA COUNTY

000000000010531

01-122002 -

EDUCATION

J.WALLERJ.WALLERJ.DIGIORGIO

DETAILS

1" = 5'-0"

C530

01/13/2026

02/13/26

V3

DSA

D E P A R T M E N T O F G E N E R A L S E R V I C E S

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

IDENTIFICATION STAMP

DIV. OF THE STATE ARCHITECT

APP: INC:

REVIEWED FOR

SS FLS ACS

DATE:

4 4 4

01-122002

D

ROOM NAME

AND NUMBER

DOOR NUMBER

WINDOW TYPE

KEYNOTE REFERENCE

NORTH ARROW

GRID LINE

WALL TYPE (SEE A611) 1S4A

REVISION CLOUD

(EXTENT OF REVISION)

SECTION REFERENCE

SECTION NUMBER

SHEET NUMBER

CENTERLINE

BREAK LINE

MATCH LINE

ELEVATION MARK

OR DATUM POINT

DETAIL REFERENCE

INTERIOR ELEVATION REFERENCE

ELEVATION NUMBER

SHEET NUMBER

ALIGN SURFACES

REVISION IDENTIFIER

T.O.PARAPET

24'-0"

OFFICE

1t

A221

EXTERIOR ELEVATION REFERENCE A2111

E A

S T

ARCHITECTURAL SYMBOLS

A5.1

A5.1

01-01SIGNAGE REFERENCE

EARTH

POROUS FILL

CONCRETE

CONCRETE BLOCK

BRICK

METAL

CONTINUOUS WOOD

SHIM OR NON-CONT. WOOD BLKING

FINISH WOOD

PLYWOOD

GYPSUM WALLBOARD

STONE

RIGID INSULATION

BATT INSULATION

ACOUSTIC TILE

PLASTER ON METAL LATH

TILE

SEALANT W/ BACK-UP MATERIAL

ARCHITECTURAL MATERIALS

ARCHITECTURAL NOTES

1. THESE SHEET NOTES OR NOTES APPLY TO THE ARCHITECTURAL DRAWINGS AND SHALL GOVERN UNLESS NOTED OTHERWISE BY

GENERAL NOTES OR KEYNOTES ON SPECIFIC SHEETS.

2. DO NOT SCALE DRAWINGS. IF DIMENSION IS NOT PROVIDED, CONSULT STATE FOR DIRECTION.

3. ALL ELEMENTS SHALL BE CONSTRUCTED IN CONFORMANCE WITH THE AMERICANS DISABILITIES ACT (ADA), 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN (ADAS), AND THE 2022 CALIFORNIA BUILDING CODE, CHAPTER 11B. WHERE THESE REGULATIONS CONFLICT, ADHERENCE TO THE PROVISION THAT PROVIDES THE HIGHEST DEGREE OF ACCESS IS REQUIRED.

4. ALL DIMENSIONS ARE TO FACE OF FINISH UNLESS OTHERWISE NOTED.

ARCHITECTURAL ABBREVIATIONS

NOTE: ADDITIONAL AND OR VARIED ABBREVIATIONS MAY BE FOUND IN OTHER DISCIPLINES. IF THERE IS A CONFLICT, ABBREVIATIONS IDENTIFIED IN OTHER DISCIPLINES DICTATE WHITHIN THE APPLICABLE DISCIPLINE DRAWINGS.

℄ CENTERLINE

⌀ DIAMETER OR ROUND

# NUMBER

AC ASPHALT CONCRETE

ACC ACCESSORY

ACM ASBESTOS CONTAINING MATERIAL

ACT ACOUSTIC CEILING TILE

AFF ABOVE FINISH FLOOR

AHU AIR HANDLING UNIT

AR ACCESSIBLE ROUTE

ARCH ARCHITECTURAL

ASB ASBESTOS

AVG AVERAGE

B BASE

BD BOARD

BLDG BUILDING

BO BOTTOM OF

BOT BOTTOM

C DEGREE CELCIUS

CATV CABLE TELEVISION

CCTV CLOSED-CIRCUIT TELEVISION

CF CUBIC FEET

CFOI CONTRACTOR FURNISHED OWNER INSTALLED

CJ CONTROL JOINT

CI CAST IRON

CLR CLEAR

CLG CEILING

CMU CONCRETE MASONRY UNIT

COL COLUMN

COMM COMMUNICATION

COMP COMPOSITION

CONC CONCRETE

CONF CONFERENCE

CONT CONTINUATION OR CONTINUOUS

CORR CORRIDOR

CP CARPET

CS CONC SEALER

CT CERAMIC TILE

DBL DOUBLE

DEPT DEPARTMENT

DEMO DEMOLITION

DF DRINKING FOUNTAIN

DIA DIAMETER

DIM DIMENSION

DISP DISPENSER

DN DOWN

DR DOOR

DS DOWNSPOUT

DW DISH WASHER

DWG DRAWING

E EAST

(E) EXISTING

EA EACH

EJ EXPANSION JOINT

EL ELEVATION

ELEC ELECTRICAL

ELEV ELEVATOR

EMER EMERGENCY

EQ EQUAL

EXP EXPANSION

EXPSD EXPOSED

EXT EXTERIOR

FA FIRE ALARM

FAAP FIRE ALARM ANNUNCIATOR PANEL

FAB FABRIC

FACP FIRE ALARM CONTROL PANEL

FD FLOOR DRAIN

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FF FINISH FLOOR

FG FINISH GRADE

FLR FLOOR

FLRG FLOORING

FLS FIRE LIFE SAFETY

FO FACE OF

FOF FACE OF FINISH

FOS FACE OF STUD

FRP FIBERGLASS REINFORCED PLASTIC

FRZR FREEZER

FS FIRE SUPPRESSION

FT FOOT OR FEET

FTG FOOTING

FV FIELD VERIFY

GA GAUGE

GAL GALLON

GALV GALVANIZED

GB GRAB BAR

GI GALVANIZED IRON

GL GLASS

GSM GALVANIZED SHEET METAL

GSP GALVANIZED STEEL PIPE

GWB GYPSUM WALL BOARD

GYP GYPSUM

GYPBD GYPSUM BOARD

HB HOSE BIBB

HM HOLLOW METAL

HORIZ HORIZONTAL

HT HEIGHT

HVAC HEATING, VENTILATION, AND AIR CONDITIONING

ID INSIDE DIAMETER

IN INCH

INSUL INSULATION

INT INTERIOR

JB JUNCTION BOX

JAN JANITOR

JT JOINT

KIT KITCHEN

L LENGTH

LAB LABORATORY

LAV LAVATORY

LB POUND

LTG LIGHTING

M METER

MAX MAXIMUM

MBL MARBLE

MC MEDICINE CABINET

MECH MECHANICAL

MEMB MEMBRANE

MFR MANUFACTURER

MIN MINIMUM

MISC MISCELLANEOUS

MM MILLIMETER

MTD MOUNTED

MTL METAL

MUL MULLION

N NORTH

(N) NEW

NIC NOT IN CONTRACT

NOM NOMINAL

NTS NOT TO SCALE

OC ON CENTER

OD OUTSIDE DIAMETER

OFCI OWNER FURNISHED CONTRACTOR INSTALLED

OFOI OWNER FURNISHED OWNER INSTALLED

OFF OFFICE

OH OPPOSITE HAND

OPP OPPOSITE

O/ OVER

P PAINT

PL PROPERTY LINE OR PLATE

PL PLANTER

PLAM PLASTIC LAMINATE

PLAS PLASTER

PLWD PLYWOOD

POT PATH OF TRAVEL

PR PAIR

PSI POUNDS PER SQUARE INCH

PT PRESSURE TREATED

PTD PAPER TOWEL DISPENSER

PVC POLYVINYL CHLORIDE

QT QUARRY TILE

R RADIUS

RCPT RECEPTION

RD ROOF DRAIN

REF REFERENCE

REFR REFRIGERATOR

REINF REINFORCED

REQ'D REQUIRED

RM ROOM

RO ROUGH OPENING

RR RESTROOM

RWD REDWOOD

RWL RAIN WATER LEADER

S SOUTH

SARU SELF-ADHERED ROOFING UNDERLAYMENT

SAWPM SELF-ADHERING WATERPROOF MEMBRANE

SCD SEAT COVER DISPENSER

SCHED SCHEDULE

SD SOAP DISPENSER

SDST SELF DRILLING SELF TAPPING

SF SQUARE FEET, SQUARE FOOT

SIM SIMILAR

SMS SHEET METAL SCREW

SND SANITARY NAPKIN DISPENSER

SNR SANITARY NAPKIN RECEPTACLE

SQ SQUARE

SSC SOLID SURFACE COUNTERTOP

SS SERVICE SINK

SST STAINLESS STEEL

ST STONE

STD STANDARD

STL STEEL

STN STAIN

STOR STORAGE

STRUCT STRUCTURAL

SUPPL SUPPLEMENTAL

T TREAD

T&B TOP AND BOTTOM

T&G TONGUE AND GROOVE

TB TOWEL BAR

TEL TELEPHONE

TEMP TEMPORARY

TER TERRAZZO

TERM TERMINATION

THK THICK

TJ TOOLED JOINT

TO TOP OF

TPD TOILET PAPER DISPENSER

TV TELEVISION

TYP TYPICAL

UON UNLESS OTHERWISE NOTED

UR URINAL

V RESILIENT FLOOR

VCT VINYL COMPOSITION TILE

VERT VERTICAL

VEST VESTIBULE

VIF VERIFY IN FIELD

W WALL

W WEST

W/ WITH

W/O WITHOUT

WC WATER CLOSET

WCHR WHEELCHAIR

WCT WAINSCOT

WCV WALL COVERING

WD WOOD

WH WATER HEATER

WP WATER PROOF

WR WATER RESISTANT

WT WEIGHT

WWF WELDED WIRE FABRIC

YD YARD

Issue

Project

Supervisor Designed Drawn

DSA App No.

Sheet Title

Project Number

Sheet Scale

Sheet Number

A x

C o p y ri g h t

C a lif o rn ia D e p a rt m e n t o f

G e n e ra l S e rv ic e s

R e a l E s ta te S e rv ic e s D iv is io n

BCDEFGHIJKLMNO

ABCDEFGHIJKLMNO

SFM Permit No.

RELATIVE BORDER SCALE IN INCHES

0 1 2 3

/2

/2

:3 :5

P

M C

P ro je c ts

\0

A

R C

C

E N

T R

A L _J a m e s.

M a d ri a g o .r vt

A001

D.Solomon J.Madriogo E.Keltgen

01-122002

ARCHITECTURAL

COVER SHEET

000000000010531

SYSTEMS REPAIR

CDE - WINDOW

500 WALNUT AVENUE

FREMONT, CA 94536

ALAMEDA COUNTY

CALIFORNIA DEPARTMENT OF

EDUCATION

N/A

V3

No. Date Description

1 2/13/26

03-20-26

DSA

D E P A R T M E N T O F G E N E R A L S E R V I C E S

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

IDENTIFICATION STAMP

DIV. OF THE STATE ARCHITECT

APP: INC:

REVIEWED FOR

SS FLS ACS

DATE:

4 4 4

01-122002

G K

(E) CLASSROOM

BLDG #53

76' - 0"

TESTING RM.

PSYCH. OFFICE

EDUC. COOR.

CLERICAL

AREA

PRINC. OFFICE

OFFICE

STAFF REPR.

WORK ROOM

HALL

10 WOMEN TOILET

MEN TOILET

STORAGE

STAFF LOUNGE

STORAGE

STUDY ROOM

STAFF KITCH.

/2

/2 "2

/2

AA101

AA521

AA521

AA101

AA101

AA521

AA521

KEYPLAN

N

SHEET LEGEND

(E) DOOR TO REMAIN

REMOVE (E) DOOR

REMOVE (E) PLUMBING FIXTURE

REMOVE (E) STOREFRONT WINDOW

SYSTEM

REMOVE PARTIAL (E) WALL FINISH TO

STUD, STUD TO REMAIN. BLDG #64

(E) WALL TO REMAIN

(E) COUNTER WALL TO BE

MODIFIED

(E) WALL TO REMAIN

REMOVE (E) CABINETS, PLUMBING

FIXTURES, AND COUNTER

NOTES:

1. ALL BUILDING ELEMENTS AND FINISHES EXISTING TO REMAIN U.O.U.

2. REMOVE EXISTING PLUMBING FIXTURES AND REMOVE/ PREPARE

CONCRETE FOR PLUMBING ADJUSTMENTS TO SUITE NEW FIXTURE

LOCATIONS.

AREA OF WORK

OFFICE

WORK ROOM

HALL

WOMEN TOILET

MEN TOILET

STORAGE

STUDY ROOM

FD

FD

02790232

02660232

Issue

Project

Supervisor Designed Drawn

DSA App No.

Sheet Title

Project Number

Sheet Scale

Sheet Number

A x

C o p y ri g h t

C a lif o rn ia D e p a rt m e n t o f

G e n e ra l S e rv ic e s

R e a l E s ta te S e rv ic e s D iv is io n

BCDEFGHIJKLMNO

ABCDEFGHIJKLMNO

SFM Permit No.

RELATIVE BORDER SCALE IN INCHES

0 1 2 3

/2

/2

:4 :0

P

M C

P ro je c ts

\0

A

R C

C

E N

T R

A L _J a m e s.

M a d ri a g o .r vt

AA101

D.Solomon J.Madriogo E.Keltgen

01-122002

BLDG 53 - DEMO

FLOOR PLAN

000000000010531

SYSTEMS REPAIR

CDE - WINDOW

500 WALNUT AVENUE

FREMONT, CA 94536

ALAMEDA COUNTY

CALIFORNIA DEPARTMENT OF

EDUCATION

N/A

V3

1/8" = 1'-0"1 DEMO FLOOR PLANNOT TO SCALE4 REF. PHOTO-MEN

NOT TO SCALE5 REF. PHOTO-WOMEN 1/4" = 1'-0"2 DEMO ENLARGED FLOOR PLAN

# DESCRIPTION

0211 REMOVE EXISTING WALL TILE AND SUBSTRATE - [TYP.]

0212 REMOVE EXISTING FLOOR TILE AND SETTING BED - [TYP.]

0217 REMOVE EXISTING TOILET PARTITION - [TYP.]

0218 REMOVE EXISTING SURFACE MOUNTED TOILET PAPER DISPENSER - [TYP.]

0220 REMOVE EXISTING SURFACE MOUNTED SEAT COVER DISPENSER - [TYP.]

0224 REMOVE EXISTING SURFACE MOUNTED SANITARY NAPKIN DISPOSAL - [TYP.]

0228 REMOVE EXISTING GRAB BAR - [TYP.]

0229 REMOVE EXISTING MIRROR - [TYP.]

0230 REMOVE EXISTING LAVATORY - [TYP.]

0231 REMOVE EXISTING LAVATORY COUNTER AND SUPPORTS - [TYP.]

0232 REMOVE EXISTING SURFACE MOUNTED PAPER TOWEL DISPENSER - [TYP.]

0233 REMOVE EXISTING RECESSED COMBINATION PAPER TOWEL, WASTE RECEPTACLE -

[TYP.]

0243 REMOVE EXISTING HOLLOW METAL DOOR - [TYP.]

0249 REMOVE EXISTING SIGN - [TYP.]

0254 REMOVE EXISTING SCREEN TYP.

0255 REMOVE EXISTING TOILET TYP.

0257 REMOVE EXISTING URINAL TYP.

0261 EXISTING FLOOR DRAIN TO REMAIN TYP.

0266 REMOVE EXISTING SOAP DISPENSER TYP.

0276 REMOVE EXISTING SINK, TYP.

0277 REMOVE EXISITNG COUNTERTOP, TYP.

0278 REMOVE EXISTING CASEWORK, TYP.

0279 REMOVE EXISTING FLOOR DRAIN

KEYNOTES

NOT TO SCALE3 REF. PHOTO

N

No. Date Description

1 2/13/26

03-20-26

DSA

D E P A R T M E N T O F G E N E R A L S E R V I C E S

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

IDENTIFICATION STAMP

DIV. OF THE STATE ARCHITECT

APP: INC:

REVIEWED FOR

SS FLS ACS

DATE:

4 4 4

01-122002

SHEET LEGEND

REMOVE (E) LIGHT FIXTURES

HVAC SUPPLY, RETURN TO REMAIN

1 X 1 ACOUSTICAL CEILING TILE TO REMAIN

(E) GYPSUM BOARD CEILING TO REMAIN

(E) LIGHT FIXTURES TO REMAIN

(E) CEILING SYSTEM TO REMAIN

REMOVE (E) SLOPE WINDOW SYSTEM

AREA OF WORK

G K

PSYCH. OFFICE

EDUC. COOR.

CLERICAL

AREA

PRINC. OFFICE

WORK ROOM

9STAFF REPR.

WOMEN TOILET

MEN TOILET

STUDY ROOM

STAFF LOUNGE

OFFICE

STAFF KITCH.

3410'-0"

8'-0"

8'-0" 8'-0" 8'-0"

8'-0"

8'-0"8'-0"

8'-0"8'-0"

8'-0" 8'-0"

8'-0"

8'-0"

8'-0"

AA102

AA102

KEYPLAN

N

WOMEN TOILET

MEN TOILET

STUDY ROOM

8'-0" 8'-0"

8'-0"

8'-0"

8'-0"

AA521

AA521

Issue

Project

Supervisor Designed Drawn

DSA App No.

Sheet Title

Project Number

Sheet Scale

Sheet Number

A x

C o p y ri g h t

C a lif o rn ia D e p a rt m e n t o f

G e n e ra l S e rv ic e s

R e a l E s ta te S e rv ic e s D iv is io n

BCDEFGHIJKLMNO

ABCDEFGHIJKLMNO

SFM Permit No.

RELATIVE BORDER SCALE IN INCHES

0 1 2 3

/2

/2

:4 :0

P

M C

P ro je c ts

\0

A

R C

C

E N

T R

A L _J a m e s.

M a d ri a g o .r vt

AA102

D.Solomon J.Madriogo E.Keltgen

01-122002

BLDG 53 - DEMO

REFLECTED CEILING

PLAN

000000000010531

SYSTEMS REPAIR

CDE - WINDOW

500 WALNUT AVENUE

FREMONT, CA 94536

ALAMEDA COUNTY

CALIFORNIA DEPARTMENT OF

EDUCATION

N/A

V3

1/8" = 1'-0"1 DEMO REFLECTED CEILING PLAN

1/4" = 1'-0"2 DEMO REFLECTED CEILING PLAN - WOMEN & MEN TOILETS1/4" = 1'-0"3 DEMO RCP STAFF LOUNGE

N

No. Date Description

1 2/13/26

03-20-26

DSA

D E P A R T M E N T O F G E N E R A L S E R V I C E S

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

IDENTIFICATION STAMP

DIV. OF THE STATE ARCHITECT

APP: INC:

REVIEWED FOR

SS FLS ACS

DATE:

4 4 4

01-122002

76' - 0"

TESTING RM.

PSYCH. OFFICE

EDUC. COOR.

CLERICAL

AREA

PRINC. OFFICE

OFFICE

STAFF REPR.

8 WORK ROOM

HALL

WOMEN TOILET

MEN TOILET

STORAGE

STAFF LOUNGE

STORAGE

STUDY ROOM

STAFF KITCH.

/2

/2 "2

/2

AA111

AA522

AA522

AA522

ST-1

AA111

KEYPLAN

N

SHEET LEGEND

(N) DOOR, SEE DOOR SCHEDULE A621

FOR MORE INFORMATION

(N) PLUMBING FIXTURE

(N) STOREFRONT WINDOW SYSTEM

(N) 2x WOOD STUD WALL

AREA OF WORK

ST-1

OFFICE

WORK ROOM

HALL

WOMEN TOILET

MEN TOILET

STORAGE

STUDY ROOM

AA221

AA221

17"-18"

5' - 2"

60" MIN.

5' - 2"

S12B

S12A

S11A

1' - 6"

FD

FD

3' - 9"

14A

14B1074

M

IN

M

IN

C

L R

M

IN

M

IN

M

IN

' M

IN

C

L R

M

IN

M

IN

3' - 0 1/2"

EQ

18" MIN

EQ

5' - 0"

STAFF KITCH.

AA1113

/4

3' - 1"

A502

A502

(E) PARTIAL

HEIGHT

WALL TO

REMAIN

REF

CL REF

' M

A X

CL CLR FLR

SPACE

OPEN

22050603 0603

1' - 2"

OPEN

OPEN

OPEN

Issue

Project

Supervisor Designed Drawn

DSA App No.

Sheet Title

Project Number

Sheet Scale

Sheet Number

A x

C o p y ri g h t

C a lif o rn ia D e p a rt m e n t o f

G e n e ra l S e rv ic e s

R e a l E s ta te S e rv ic e s D iv is io n

BCDEFGHIJKLMNO

ABCDEFGHIJKLMNO

SFM Permit No.

RELATIVE BORDER SCALE IN INCHES

0 1 2 3

/3

/2

:1

:0 P

M C

P ro je c ts

\0

A

R C

C

E N

T R

A L J a m e s .M a d ri a g o

.r vt

AA111

D.Solomon J.Madriogo E.Keltgen

01-122002

BLDG 53 - FLOOR

PLAN

000000000010531

SYSTEMS REPAIR

CDE - WINDOW

500 WALNUT AVENUE

FREMONT, CA 94536

ALAMEDA COUNTY

CALIFORNIA DEPARTMENT OF

EDUCATION

N/A

V3

1/8" = 1'-0"1 FLOOR PLAN

KEYNOTES

# DESCRIPTION

0603 SOLID SURFACE COUNTER TOP

1001 SURFACE MOUNTED TOILET TISSUE DISPENSER, FOR TYP. MOUNTING HEIGHTS SEE

DETAILS 1/A504

1005 SURFACE MOUNTED SEAT COVER DISPENSER, TYP. MOUNTING HEIGHTS SEE

DETAILS 1/A504

1009 SURFACE MOUNTED SANITARY NAPKIN DISPOSAL

1013 48" GRAB BAR, TYP. FOR ATTACHMENT SEE DETAILS 15/A502 AND 1&2/A502

1014 42" GRAB BAR, TYP. FOR ATTACHMENT SEE DETAILS 15/A502 1&2/A502

1016 SURFACE MOUNTED PAPER TOWEL DISPENSER, FOR TYP. MOUNTING HEIGHTS SEE

DETAILS 1/A504

1018 SEMI-RECESSED PAPER TOWEL DISPENSER AND WASTE RECEPTACLE, TYP.

MOUNTING HEIGHTS SEE DETAILS 1/A504

1023 RECESSED SANITARY NAPKIN DISPENSER UNIT, FOR TYP. MOUNTING HEIGHTS SEE

DETAILS 1/A504

1025 COUNTER MOUNTED AUTOMATIC LIQUID SOAP DISPENSER TYP. MOUNTING HEIGHTS

SEE DETAILS 1/A504

1035 SOLID TOILET COMPARTMENTS, SEE DETAIL 14/A502

1037 URINAL SCREEN

1072 COAT HOOK TYP. MOUNTING HEIGHTS SEE DETAILS 1/A504

1073 MIRROR TYP.

1074 PUSH PLATE FOR DOOR OPERATOR, SEE DETAIL 3/A504

2202 WATER CLOSET, TYP. MOUNTING HEIGHTS SEE DETAILS 1&5/A502

2203 URINAL, TYP. MOUNTING HEIGHTS SEE DETAIL 8/A502

2204 ACCESSIBLE RESTROOM SINK, DROP-IN, SEE DETAIL 7/A502

2205 ACCESSIBLE SINK, SEE DETAIL 19/A502

2221 FLOOR DRAIN TYP. SEE DETAIL 12/A502

2224 COUNTER MOUNTED AUTOMATIC FAUCET, TYP

1/4" = 1'-0"2 BLDG 53 ENLARGED FLOOR PLAN1/4" = 1'-0"4 CASEWORK PLAN

1/4" = 1'-0"3 INTERIOR ELEVATION

REF.

N

No. Date Description

1 2/13/26

NOTES:

1. COMBINATION REFRIGERATORS AND FREEZERS SHALL HAVE AT LEAST

50% OF THE FREEZER SPACE 54 INCHES MAXIMUM ABOVE THE FINISH

FLOOR OR GROUND.

2. FOR TYPICAL MOUNTING HEIGHTS AND REACH RANGE SEE DETAIL 1/A504.

04-30-26

DSA

D E P A R T M E N T O F G E N E R A L S E R V I C E S

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

IDENTIFICATION STAMP

DIV. OF THE STATE ARCHITECT

APP: INC:

REVIEWED FOR

SS FLS ACS

DATE:

4 4 4

01-122002

10'-0" 8'-0"

8'-0" 8'-0" 8'-0"

8'-0"

8'-0"8'-0"

8'-0"8'-0"

8'-0" 8'-0"

8'-0"

8'-0"

8'-0"

PSYCH. OFFICE

EDUC. COOR.

CLERICAL

AREA

WORK ROOM

STUDY ROOM

WOMEN TOILET

MEN TOILET

OFFICE

PRINC. OFFICE

STAFF LOUNGE

STAFF KITCH.

STORAGE

STAFF REPR.

TESTING RM.

AA112

AA112

SHEET LEGEND - RCP

1 x 1 ACOUSTICAL CEILING TILE TO

REMAIN

SUPPLY TO REMAIN

RETURN TO REMAIN

(E) GYPSUM BOARD CEILING TO REMAIN

LIGHT FIXTURE TO REMAIN

AREA OF WORK

GYPSUM BOARD CEILING

KEYPLAN

N

8'-0" 8'-0"

8'-0"

8'-0"

8'-0"

WORK ROOM

WOMEN TOILET

MEN TOILET

OFFICE

AA522

Issue

Project

Supervisor Designed Drawn

DSA App No.

Sheet Title

Project Number

Sheet Scale

Sheet Number

A x

C o p y ri g h t

C a lif o rn ia D e p a rt m e n t o f

G e n e ra l S e rv ic e s

R e a l E s ta te S e rv ic e s D iv is io n

BCDEFGHIJKLMNO

ABCDEFGHIJKLMNO

SFM Permit No.

RELATIVE BORDER SCALE IN INCHES

0 1 2 3

/2

/2

:4 :0

P

M C

P ro je c ts

\0

A

R C

C

E N

T R

A L _J a m e s.

M a d ri a g o .r vt

AA112

D.Solomon J.Madriogo E.Keltgen

01-122002

BLDG 53 -

REFLECTED CEILING

PLAN

000000000010531

SYSTEMS REPAIR

CDE - WINDOW

500 WALNUT AVENUE

FREMONT, CA 94536

ALAMEDA COUNTY

CALIFORNIA DEPARTMENT OF

EDUCATION

N/A

V3

1/8" = 1'-0"1 REFLECTED CEILING PLAN

KEYNOTES

1/4" = 1'-0"2 ENLARGED REFLECTED CEILING PLAN - WOMEN & MEN RESTROOMS1/4" = 1'-0"3 RCP STAFF LOUNGE

N

No. Date Description

1 2/13/26

03-20-26

DSA

D E P A R T M E N T O F G E N E R A L S E R V I C E S

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

IDENTIFICATION STAMP

DIV. OF THE STATE ARCHITECT

APP: INC:

REVIEWED FOR

SS FLS ACS

DATE:

4 4 4

01-122002

1035 09120958 1072

22020912 1005

10090958 0912 1014

1035 1073

OPEN

0603 1018

O F

O P

E R

A B

L E

P A

R T

T O

T O

P

1073 1037

2203 1035 1014

0912 09121013

1001 0958

09120958

O F

O P

E R

A B

L E

P A

R T

T O

T O

P

OPEN

KEYPLAN

N

SHEET NOTES

1. SEE DETAIL 1/A504 FOR TYPICAL ACCESSIBLE MOUNTING HEIGHTS

2. XX

Issue

Project

Supervisor Designed Drawn

DSA App No.

Sheet Title

Project Number

Sheet Scale

Sheet Number

A x

C o p y ri g h t

C a lif o rn ia D e p a rt m e n t o f

G e n e ra l S e rv ic e s

R e a l E s ta te S e rv ic e s D iv is io n

BCDEFGHIJKLMNO

ABCDEFGHIJKLMNO

SFM Permit No.

RELATIVE BORDER SCALE IN INCHES

0 1 2 3

/3

/2

:1

:5 P

M C

P ro je c ts

\0

A

R C

C

E N

T R

A L J a m e s .M a d ri a g o

.r vt

AA221

D.Solomon J.Madriogo E.Keltgen

01-122002

BLDG 53 - INTERIOR

ELEVATIONS

RESTROOM

000000000010531

1/4"=1'-0"

SYSTEMS REPAIR

CDE - WINDOW

500 WALNUT AVENUE

FREMONT, CA 94536

ALAMEDA COUNTY

CALIFORNIA DEPARTMENT OF

EDUCATION

N/A

V3

1/4" = 1'-0"1 WOMEN TOILET 11 (BLDG 53)

1 NORTH 2 EAST 3 SOUTH 4 WEST

1/4" = 1'-0"5 MEN TOILET 12 (BLDG 53)

5 NORTH 6 EAST 8 WEST7 SOUTH

KEYED NOTES

# DESCRIPTION

0603 SOLID SURFACE COUNTER TOP

0912 CERAMIC TILE TYP. SEE FINISH SCHEDULE

0958 INTERIOR PAINT

1001 SURFACE MOUNTED TOILET TISSUE DISPENSER, FOR TYP. MOUNTING HEIGHTS SEE

DETAILS 1/A504

1005 SURFACE MOUNTED SEAT COVER DISPENSER, TYP. MOUNTING HEIGHTS SEE

DETAILS 1/A504

1009 SURFACE MOUNTED SANITARY NAPKIN DISPOSAL

1013 48" GRAB BAR, TYP. FOR ATTACHMENT SEE DETAILS 15/A502 AND 1&2/A502

1014 42" GRAB BAR, TYP. FOR ATTACHMENT SEE DETAILS 15/A502 1&2/A502

1018 SEMI-RECESSED PAPER TOWEL DISPENSER AND WASTE RECEPTACLE, TYP.

MOUNTING HEIGHTS SEE DETAILS 1/A504

1023 RECESSED SANITARY NAPKIN DISPENSER UNIT, FOR TYP. MOUNTING HEIGHTS SEE

DETAILS 1/A504

1025 COUNTER MOUNTED AUTOMATIC LIQUID SOAP DISPENSER TYP. MOUNTING HEIGHTS

SEE DETAILS 1/A504

1035 SOLID TOILET COMPARTMENTS, SEE DETAIL 14/A502

1037 URINAL SCREEN

1072 COAT HOOK TYP. MOUNTING HEIGHTS SEE DETAILS 1/A504

1073 MIRROR TYP.

2202 WATER CLOSET, TYP. MOUNTING HEIGHTS SEE DETAILS 1&5/A502

2203 URINAL, TYP. MOUNTING HEIGHTS SEE DETAIL 8/A502

No. Date Description

1 2/13/26

04-30-26

DSA

D E P A R T M E N T O F G E N E R A L S E R V I C E S

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

DSA

DIVISION OF THE STATE ARCHITECT

IDENTIFICATION STAMP

DIV. OF THE STATE ARCHITECT

APP: INC:

REVIEWED FOR

SS FLS ACS

DATE:

4 4 4

01-122002

KEYPLAN

N

AA521

(E) EXTERIOR CEMENT

PLASTER

23' - 4"

REMOVE (E)

STOREFRONT SYSTEM

AA521

PORTION OF (E) EXTERIOR

CEMENT PLASTER TO BE

REMOVED, PRESERVE

WEATHER BARRIER

4' - 6"

AA521

AA521

REMOVE (E)

STOREFRONT WINDOW

SYSTEM

(E) ROOF TO REMAIN

UNDISTUBED

(E) WALL BEYOND

(E) 6" x 6"…

This is the start of the file's text. The full file is on GovTribe.