This document appears to be a detailed technical specification for a security system upgrade across multiple rooms. The project involves installing a new iSTAR Ultra Control Panel in Room 306, replacing the existing power supply with a battery backup capable of operating for at least 4 hours without commercial power. The scope includes upgrading the Intrusion Detection System (IDS) Panel to a DSC PowerSeries Pro, with a power supply that can operate 24 hours without commercial power.

The upgrade encompasses multiple rooms (RM301-RM323), with specific requirements for each room's access control system. This includes installing or modifying card readers, electric locks, door position switches, and request-to-exit (REX) devices. Each room's system will be connected to the new iSTAR Ultra Panel in Room 306, with new power supplies featuring 4-hour battery backup. The total device count includes 29 motion sensors, 2 balanced magnetic door switches, and 2 tamper switches. The project also involves migrating existing software (C-Cure 9000 v2.01) to a new government-furnished computer and ensuring all existing and new doors are functional.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

iS T A R

P o

Install new iSTAR Ultra Control Panel. Replace existing power supply with battery backup sufficient to operate at least 4 hours without commercial power. Reestablish Software House

SSA, install current version of C-Cure 9000 on new government furnished computer, migrate data from existing C-Cure 9000 v

2.01 to new computer. Test and verify all existing doors and new doors are functional.

N e w i S T A R

U lt ra P a n e l

U p g ra d e I

D S

P a n e l

Upgrade existing Intrusion Detection System (IDS) Panel, modules and key-pad to DSC PowerSeries Pro. Replace power supply with DSC power supply with battery backup sufficient to operate 24 hours without commercial power. Utilize existing utility can.

DEVICE COUNT

29 Motion Sensors (12v DC 30ma)

2 Balanced Magnetic Door Switches

2 Tamper Switches

CUI

CUI

RM301

RM303 RM304

RM302

RM306

RM307

RM309 RM311

RM309

RM313

RM314

RM4E

RM4E

Keep existing card reader,. New Lock, door position switch and REX.

Existing Box Above Ceiling. Utilize exiting utility can or replace with new can. Provide new power supply with battery backup suf-ficient for 4 hours of operation without commercial power. Con-nect RM4E to new iSTAR Ultra Panel in RM 306.

Remove Existing

Magnetic lock.

Install new Card Reader, door position switch, electric lock and request-to-exit (REX). Utilize exiting utility can or replace with new can. Provide new power supply with battery backup suffi-cient for 4 hours of operation without commercial power. Install new RM4E. Connect to new iSTAR Ultra Panel in RM 306.

Keep existing card reader,. New Lock, door position switch and REX. Utilize exiting utility can or replace with new can.

Provide new power supply with battery backup sufficient for 4 hours of operation without commercial power. Connect RM4E to new iSTAR Ultra Panel in RM 306

CUI

CUI

RM316

RM315

RM317

RM318

RM320

RM321

RM323