DRAWING 2AI104-E2 M7 DNT FOURTH FLOOR PLAN - AREA E1 AND E2.pdf
PDF 597 KB Posted
- Attached to
- Z1DA--Installation of Additional Environmental Monitors Federal contract opportunity
- Solicitation number
- 36C25621R0131
About this file
This document includes a floor plan drawing and federal contract opportunity notice. The floor plan drawing depicts the layout of areas E1 and E2 on the fourth floor of Building 2, including room names, numbers, and square footages. The federal contract opportunity is a presolicitation notice for the installation of additional environmental monitors at the Southeast Louisiana Veterans Health Care System in New Orleans. The estimated value of the construction work is between $500,000 and $1,000,000. The applicable NAICS code is 238220 and size standard is $16.5 million. The solicitation will be issued on June 4, 2021 as a 100% set-aside for verified Service-Disabled Veteran-Owned Small Businesses. Interested SDVOSBs must be registered in the Vendor Information Pages and System for Award Management databases by the response date.
View the file
Other files for this federal contract opportunity
Show all 47
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
H
Y20
5.3
7.6
8.1
6.1
CORR
4E-C09B
2AI104-D2
2AI104-E2
4E-C09A
CORR
4E-C05A
CORR
4E-C09B
STORAGE
BULK
4E110
STORAGE
FLAMMABLE
4E114
STORAGE
REFRIG
4E108
SPEC
ACCESS
4E103A
URINE
4E125D
EC
4E136
MED
TECH
4E107
ST
4E113
ST
4E112
CLEAN
STOR
4E115
TOXICOLOGY
4E127
MED
TECH
4E120
CORR
4E-C04A
CORR
4E-C07A
CORR
4E-C08B
CORR
4E-C09A
STUDENT
4E118B
STUDENT
4E118A
CORR
4E-C04B
HEMA
COAG/ROUTINE
LAB
4E125E
CORR
4E-C08A
H
CYLINDER
4E138
HK
4E106
ST
4E117
STORAGE
4E101
4E227
4E227.3
4E101
4E
4E
4E105
4E
5E .3
4E
5E .1
4E-C04A.2
4E114 4E
4E
4E
5E .4
4E
4E
4E115
4E
3.
4E103.3
4E
4E
4E
5E .2
4E
4E
4E116
4E
7.
4E
4E
7.
4E127
4E138
4E
3.
4E-C04A.1
4E -C
B
4E
4E
4E
4E118
4E125
4E -C
A
FEC 20
H V
C
MED
TECH
(NIGHT
SUPER)
4E111
MED
TECH
(HEMATOLOGY)
4E109
MED
TECH
(BB)
4E105
MED TECH
4E102
CLIN
CHEM
4E125
BLOOD
BANK
4E129A
STORAGE
STERILE
PREP
4E116
FEW
FEW
CLASS/LAB
4E119
2AI104-E2
2AI104-F2
FEC
MED
TECH
4E121
FEC 20
FEC
HVC
HVC
EXTERIOR:
ROOF
EXTERIOR:
ROOF
EXTERIOR
OPEN TO BELOW
EXTERIOR
OPEN TO BELOW
EXTERIOR:
ROOF
CR
4E-C01
SERVICE
BAY
4E227E
EMER
COMMAND
CENTER
4E145
STORAGE
4E101
TELECOM
4E227A
SERVICE
BAY
4E227
NORM
ELEC
4E227D
EMER
ELEC
4E227C
SECURITY
4E227B
4E227
4E145.2
4E
7C
4E
7D
4E
7B
4E
7A
4E227.3
4E101
CR
4E145.1
CR CR
HVC
HVC
FEW
FEW
FEC
SHAFT
SHE06
SHAFT
SHE06A
EXTERIOR:
ROOF
UP
2AI104-D2
2AI104-E2
22SF
734SF
229SF
4E154
19SF
4E151
675SF
4E122A
4E122
667SF
4E122B
3766SF
4E122C
991SF
4E201
1132SF
4E201A
95SF
4E201B
64SF
4E201C
161SF
4E201D
159SF
4E130
134SF
4E140
120SF
311SF
4E126
127SF
4E128
119SF
4E124
100SF
4E120
120SF
4E141
472SF
4E139
63SF
4E136
167SF
4E138
422SF
4E133
66SF
4E131
67SF
4E137
403SF
4E135
147SF
4E129
671SF
4E127
172SF
4E125
72SF
4E123
836SF
4E121
119SF
4E203
1039SF
4E205A
564SF
4E205
290SF
4E122E
4E136C
4E136A
209SF
320SF
139SF
740SF
825SF
824 SF
4E141A
4E141B
STUDENT
4E136B
E
A
E
A
E
A
E
A
E
A
E
A
CORR
4D-C08
CLERICAL
4D126B
TEACH
COORD
4D104C
CONFERENCE
4D141
CHIEF
4D125
LOUNGE
4D140
BIO
MED
CIMN
4E135
CLERICAL
4D126A
DRUG
INFO
4D126
CHIEF
4D124
BULK
STORAGE
4D159
HK
4D139
CONF
TRAIN
4D169
LINEN
PACKS
4D160
HC S
T/S
4D168
LOCKERS
4D165
LOCKERS
4D166
HC S
T/S
4D167
CHEM
STOR
4E137A
EMS
STORAGE
4E137
HVC
H V
C F
E C
66SF
166SF
242SF
300SF
453SF
297SF
114SF
102SF
583SF
BIO
MED
CIMN
4E135
EC
4E136
CHEM
STOR
4E137A
4E
4E
7.
4E
4E
7.
4E137A
HVC
H V
C H
V C
F E
C
EXTERIOR
OPEN TO BELOW
STAIR
STD-18
TEACH
COORD
4D104C
EMER
ELEC
4D227B
NORM
ELEC
4D227A
4D104D
HVC
SHD03
EXTERIOR
OPEN TO BELOW
136SF
135SF
1667SF
44SF
EXTERIOR
OPEN TO BELOW
109SF
76SF
64SF
25SF
22SF
4D224
4D226
4D226A
4D226B
4D226C
4D226D
4D110DA
4D110D
4D110DA5
4D110DA3
4D110DA4
4D110J
4D110G
4D110H
4D101A
4D101B
4E152
4E150
4E150A
4E154
4E152A
4E152B
4E152C
4E152D
4E152F
4E152E
CLO.
4E122F
13SF
CORRCORR
4D-C03.1
407SF
CORRCORR
4E-C03.1
1167SF
CORRCORR
4E-C09B1
559 SF
704 SF
CORR
4D-C06A
USED BY
FMS
USED BY
FMS
EXAM
1D###
1D###
125 S.F
ROOM NAME
OLD ROOM #
NEW ROOM #
SQ. FOOTAGE
NEW AND OLD ROOM NUMBER LEGEND
Q
D2 D1
E2 E1
F2 F1
G2 G1
A2
A4
A5
A1
A6
B1
C1 C2
B2
H
J1 J2
L
K
M1 M2
M3
P
N1 N2
A7
D3
E3
F3
R1
R4
R2
R3
A3
PLAN
NORTH
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T O
N E
H
AL
F
IN
C H
O
N E
FO
O
T
TH
R
EE
Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
EE
T
(1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
XT
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
ES
O N
E
FO
O T
6"
BUILDING NUMBER
BLDG 2 FOURTH FLOOR PLAN - AREA E2
ML AG/DMKFebruary 29, 2012
02629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
NEW ORLEANS, LOUISIANA
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT
Department of Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
WP_08
CONSTRUCTION DOCUMENTS 1
FULLY SPRINKLERED
I.S.C. GROUP, INC. / IRRIGATION
DAN EUSER WATER ARCHITECTURE, INC. / WATER FEATURE
SCALE: 1/8" = 1'-0"
BLDG 2 FOURTH FLOOR PLAN - AREAS E1 AND E2
15 BULL 015B - PRE-AWARD 08/30/2013
16 BULL 015B - VE 08/30/2013
19 BULL 015C - VE 10/15/2013
DIAGNOSTIC AND TREATMENT BUILDING
REVISED STAIRWELL NUMBER 06/10/2020
SERVICE BAY USE UPDATE 08/24/2020
VHANOLChinE Typewritten Text
X NEW ROOM PRESSURE MONITOR
VHANOLChinE Typewritten Text X
NEW ROOM PRESSURE MONITOR,
REMOVE WALL TO ROUTE ELECTRICAL
AND CONTROL WIRING IN CONDUIT
INSIDE WALL, INSTALL NEW WALL,
PAINT ENTIRE SIDE TO MATCH EXISTING
COLOR.
VHANOLChinE Line
File details come from the government source that posted it. Updated .