DRAWING 1AI104-B2 IP Fourth Wall Types Building B2.pdf

PDF 453 KB Posted

Attached to
Z1DA--Installation of Additional Environmental Monitors Federal contract opportunity
Solicitation number
36C25621R0131
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 16

About this file

This document package includes a floor plan drawing and specifications for a federal construction project, along with a presolicitation notice for additional environmental monitors at a Veterans Health Administration facility.

The floor plan drawing and specifications are for the replacement medical center project at the Southeast Louisiana Veterans Health Care System in New Orleans. The drawing shows the fourth floor plan for Building B2 and includes notes on partition types, door and relite schedules, references to other drawings, and other construction details. The presolicitation notice indicates the Veterans Health Administration will be issuing a request for proposal around June 4, 2021 for the installation of additional environmental monitors at the New Orleans facility, with an estimated construction cost between $500,000 and $1 million. The solicitation will be set aside for service-disabled veteran-owned small businesses, who must meet certain limitations on subcontracting and be registered and verified in federal databases to be considered for award. Interested offerors should check the beta.SAM website for the full RFP and any amendments.

View the file

Other files for this federal contract opportunity

Other files attached to Z1DA--Installation of Additional Environmental Monitors, newest first.
File Type Posted
S04 Site Visit Sign-In Sheet (06.17.2021).pdf PDF
36C25621R0131 0001.docx DOCX document
EXHIBIT C SUBCONTRACTOR INFORMATION AND CONSENT.docx DOCX document
MANUAL Setra Installation and Operating Manual.pdf PDF
PHOTO 4CC01A.jpg JPG image
PHOTO 4BC02.jpg JPG image
DRAWING 1AI102 M1 IP OVERALL SECOND FLOOR PLAN.pdf PDF
DRAWING 1A104-QUESTION MARK M3 IP OVERALL FOURTH FLOOR PLAN.pdf PDF
26 05 11 Requirements for Electrical Installations.pdf PDF
01 45 00 Quality Control.pdf PDF
GENERAL DECISION NUMBER LA20210041.pdf PDF
36C25621R0131 SOL.docx DOCX document
EXHIBIT B PAST AND PRESENT PERFORMANCE QUESTIONNAIRE.docx DOCX document
CHART M11 Environmental Monitor Room Location List.pdf PDF
26 05 19 Low Voltage Electrical Power Conductors and Cables 600 Volts and Below.pdf PDF
23 05 11 Common Work Results for HVAC.pdf PDF
09 91 00 Painting.pdf PDF
02 41 00 Demolition.pdf PDF
01 33 23 Shop Drawings Product Data and Samples.pdf PDF
01 00 00 General Requirements.pdf PDF
00 01 10 Table of Contents.pdf PDF
SOW (Final).pdf PDF
EXHIBIT G LIST OF RETURNABLES.docx DOCX document
EXHIBIT F REQUEST FOR INFORMATION FORM.docx DOCX document
EXHIBIT A PERFORMANCE RELEVANCY SURVEY.docx DOCX document
DRAWING 2AI104-D2 M4 DNT FOURTH FLOOR PLAN - AREA D1 AND D2.pdf PDF
DRAWING 2AI103-D2 M5 DNT THIRD FLOOR PLAN - AREA D1 AND D2.pdf PDF
DRAWING 2AI102-G2 M8 DNT SECOND FLOOR PLAN - AREA G1 AND G2.pdf PDF
DRAWING 1AI103-QUESTION MARK M2 IP OVERALL THIRD FLOOR PLAN.pdf PDF
26 05 33 Raceway and Boxes for Electrical Systems.pdf PDF
23 09 23 Direct Digital Control System For HVAC.pdf PDF
01 42 19 Reference Standards.pdf PDF
Justification and Approval (Brand Name).pdf PDF
DRAWING 2AI104-E2 M7 DNT FOURTH FLOOR PLAN - AREA E1 AND E2.pdf PDF
EXHIBIT E SURETY FORM.docx DOCX document
EXHIBIT D CONTRACTOR EVALUATION FORM CONSTRUCTION SAFETY.docx DOCX document
JCI Temperature Humidity Sensor Cutsheet.pdf PDF
CUTSHEET Serta Room Pressure Monitor Cutsheet.pdf PDF
DRAWING 8AS103 M9 RESEARCH THIRD FLOOR PLAN.pdf PDF
DRAWING 2AI102-F2 M10 DNT SECOND FLOOR PLAN - AREA F1 AND F2.pdf PDF
DRAWING 1AI104-C1 IP Fourth Wall Types Building C1.pdf PDF
DRAWING 1AI104-B1 IP Fourth Wall Types Building B1.pdf PDF
2AI102-E2 M6 DNT SECOND FLOOR PLAN -AREA E1 AND E2.pdf PDF
09 29 00 Gypsum Board.pdf PDF
07 84 00 Firestopping.pdf PDF
01 35 26 Safety Requirements.pdf PDF
ICRA ILSM.xlsx XLSX spreadsheet
Show all 47

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DN

UP

1 A I1

-B

1 A

I1

-B

PATIENT

4B163

REF:2B145

PATIENT

4B161

REF:2B145

PATIENT

4B159

REF:2B145

PATIENT

4B157

REF:2B145

PATIENT

4B152

REF:2B145

PATIENT

4B164

REF:2B145

PATIENT

4B162

REF:2B145

PATIENT

4B160

REF:2B145

PATIENT

4B158

REF:2B145

PATIENT

4B156

REF:2B145

PATIENT

4B154

REF:2B145

PATIENT

4B151

REF:2B145

PATIENT

4B150

REF:2B145

ANTE

POS

4B165B

REF:2B165B

PATIENT

POS

4B165

REF:2B145

L

K

H

M

STAIR

STB-2

EC

4B153

REF:2B153

T

4B151A

REF:2B145A

T

4B150A

REF:2B145A

T

4B154A

REF:2B145A

T

4B156A

REF:2B145A

T

4B158A

REF:2B145A

T

4B160A

REF:2B145A

T

4B162A

REF:2B145A

T

4B164A

REF:2B145A

T

4B163A

REF:2B145A

T

4B161A

REF:2B145A

T

4B159A

REF:2B145A

T

4B157A

REF:2B145A

T

4B152A

REF:2B145A

SUB-STATION

4B132H

REF:2B130A

SUB-STATION

4B132D

REF:2B130A

SUB-STATION

4B132F

REF:2B130A

T

4B167

REF:2B167

ISO T

4B165A

REF:2B145A

CC

4B165C

REF:2B155A

AISLE

4B-C03A

1AS711

F2

CC

4B155A

REF:2B155A

SOILED

4B155E

REF:2B155E

CLEAN

4B155D

REF:2B155D

MED

4B155B

REF:2B155B

NOUR

4B155F

REF:2B155F

1.8

2.5

M.1

SUPPLY

4B132A

REF:2B130B

SUB-STATION

4B132B

REF:2B130A

SUPPLY

4B132C

REF:2B130B

G.6

CR

4B167

4B156.24B154.2 4B160.24B158.2 4B162.2

4B151.2 4B159.2 4B161.2 4B163.2

4B

5.

4B

5.

4B155B 4B155E

4B153

4B -C

4B150.2

4B

0.

4B157.2

4B

7.

4B152.2

4B

4.

4B164.2

SUPPLY

4B132G

REF:2B130B

SUPPLY

4B132E

REF:2B130B

J

EQ EQ

STP

FEC

FEC

1.3 01

1.4

1AI424

A2

SIM

1AI424

F3

SIM

A_6AC

A_ 6A

C

A_8ACA_6AC

J_4CJ_4C

J_4CJ_4C

A16AB

A14AB

A16AB

A16AB

A14BA14B 01

4B

1.

4B

9.

4B

1.

4B

3.

4B

6.

4B

4.

4B

0.

4B

8.

4B

2.

4B

2.

V16AB

CORR

4B-C03

REF:2B-C03

CORR

4B-C03

J_4

4B165.2

4B

5.

4B

5D

102 102

102 102

4.9

0AI510.2

B5

0AI510.1

C4

0AI510.2

A2

0AI510.2

A5

0AI510.2

A5

0AI510.2

B5

0AI510.1

B4

4B155C

TELECOM

4B155C

REF:2B155C

4B -S

TB

-2

Q

D2 D1

E2 E1

F2 F1

G2 G1

A2

A4

A5

A1

A6

B1

C1 C2

B2

H

J1 J2

L

K

M1 M2 M3

P

N1 N2

A7

D3

E3

F3

R1

R4

R2 R3

A3

PLAN

NORTH

DATE

LOCATION

CHECKED DRAWN

PROJECT TITLE PROJECT NUMBER

DOCUMENT SET PACKAGE

DRAWING NUMBERAPPROVED: PROJECT DIRECTOR

DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:

REVISIONS: DATE

B

A

D

C

E

VA FORM 08-6231

O N

E

EI

G H

T

IN

C H

O

N E

FO

O

T O

N E

Q U

AR

T E

R

IN

C H

O

N E

FO

O

T O

N E

H

AL

F I N

C H

O

N E

FO

O

T

TH

R

EE

Q U

A R

TE

R S

IN

C

H

O N

E

FO

O T

TH

R

EE

IN

C H

ES

O N

E

FO

O T

O N

E

IN

C H

F

O R

TY

F

EE

T

( 1

0'

6"

6"

0'

0'

123456

F

B

A

D

C

E

F

O N

E

SI

XT

EE

N

TH

IN

C

H

O N

E

FO

O T

O N

E

AN

D O

N E

H

AL

F

IN

C H

E S

O N

E

FO

O T

6"

BUILDING NUMBER

NEW ORLEANS, LOUISIANA

1AI104-B2

BLDG 1 FOURTH FLOOR PLAN - AREA B2

ML AG/DMKFebruary 29, 2012

01629-HS2-401SLVHCS REPLACEMENT MEDICAL

CENTER PROJECT

SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL

KORDA/NEMETH ENGINEERING / STRUCTURAL

BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE

ARCHITECTURAL ENGINEERING / PLUMBING

SCALES ASSOCIATES / FIRE PROTECTION

DESMAN ASSOCIATES / PARKING

CODE CONSULTANTS, INC. / CODE CONSULTANT

THE SEXTANT GROUP / AV & ACOUSTICAL

HAMMER DESIGN ASSOCIATES / FOOD SERVICE

PYBURN & ODOM / ABATEMENT

TATA & HOWARD / TANK CONSULTANT

Department of

Veterans Affairs

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

WP_08

CONSTRUCTION DOCUMENTS 1

FULLY SPRINKLERED

I.S.C. GROUP, INC. / IRRIGATION

DAN EUSER WATER ARCHITECTURE, INC. / WATER FEATURE

SCALE: 1/8" = 1'-0"1

GENERAL FLOOR PLAN NOTES

SLAB OPENING - REF STRUCTURAL DWGS

ALIGN PARTITIONS

LINE OF CURTAIN WALL SILL - REF EXTERIOR SERIES DWGS.

LINE OF HOISTWAY BELOW

AIR HANDLER UNIT - REF MECHANICAL DWGS

STEEL BRACING - REF STRUCTURAL DWGS

CONCRETE HOUSEKEEPING PAD - REF STRUCTURAL DWGS

ACCORDIAN FIRE DOOR - REF DOOR SCHEDULE

: 14 92 00 PNEUMATIC TUBE STATION - REF DETAILS C4 &

C5/0AI507.

08 31 13 FLOOR VAULT DOOR - 36" X 36". REF DTL E1/0AI516

ROOF/OVERFLOW DRAIN LEADER - REF PLUMBING DWGS

ELECTRICAL PANEL - REF ELECTRICAL DWGS

MEDICAL GAS ZONE VALVE BOX/MEDICAL GAS ALARM PANEL - REF MED

GAS DWGS

SLOPE FLOORING IN SHOWER/TOILET ROOM TO FLOOR DRAIN

SLAB RECESS FOR HIGH DENSITY SHELVING TRACK. VFY RECESS

DIMENSION W/ SHELVING MANUFACTUER.

14 91 34 TRASH/LINEN CHUTE & STATION: SEE DETAILS E6/0AI507

14 91 34 TRASH/LINEN CHUTE: NO LOADING STATION

14 91 34 TRASH/LINEN CHUTE: PROVIDE SLEEVES @ LEVEL 01 FLOOR

SLAB PENETRATION - SEE DETAILS E6/0AI507

08 31 13 3-HOUR FIRE RATED ACCESS PANEL - 24" X 48".

ELECTRICAL RISERS - SEE PLAN DETS ON F5/0AI512 - REF ELEC DWGS

CONCRETE ENCASED ELECTRICAL FEEDERS ABOVE - REF STRUCTURAL &

ELEC DWGS

09 27 02 GLASS FIBER REINFORCED GYPSUM COLUMN COVER -

36" O.D. UON.

BOLD DASHED LINE INDICATES ROUTE OF STRUCTURAL EXPANSION JOINT

- REF STRUCTURAL DWGS. REFERENCE FLOOR PLAN LEGEND FOR

INTERIOR EXPANSION JOINT COVER ASSEMBLY INFORMATION.

10 11 00 MARKER BOARD REF INTERIOR ELEV SHEET NOTE 207.

10 11 00 TACK BOARD REF INTERIOR ELEV SHEET NOTE 208.

10 28 00 FOLD-DOWN BENCH

10 28 00 FOLD-DOWN SHOWER SEAT

SLAB RECESS FOR WALK-OFF GRILLE. VFY RECESS DIMENSION W/

GRILLE MANUFACTURER. SEE FLOOR FINISH PLANS FOR EXTENTS.

PLUMBING ROUGH-IN FOR FUTURE SINK - REF PLUMBING DWGS.

BENT PLATE W/ TRAFFIC COATING WRAP @ WALL BASE - REF B3/0AI516

LINE OF 2-HR RATED SHAFT ABOVE. REF DETAILS E1 & E3 SHT 0AI507

05 05 00 ACCESS LADDER

10 33 13 WIRE MESH PARTITION

05 52 13 PIPE AND TUBE RAILING

11 13 00 MANUAL DOCK LEVELER AND BUMPERS

13 44 00 MODULAR MEZZANINES INCL. STAIRS & WIRE MESH PTNS.

05 50 00 METAL GRATE CATWALK

WALL MOUNTED HAND SINK - REF PLUMBING DWGS

RECESSED EMERGENCY SHOWER AND EXPOSED STAINLESS STEEL

SHOWER HEAD - REF PLUMBING DWGS

08 39 19 FLOOD BARRIERS: FLOOD PLANK SYSTEM - REF D5/0AI511

CONC. WALLS @ L 01 ELEV SHAFTS - REF STRUCT DWGS & DTL D2/0AI507

BENT PLATE W/ PEDESTRIAN TRAFFIC COATING WRAP - REF C3/0AI516

PLENUM SYSTEM - SEE EXTERIOR DRAWINGS

CENTER PARTITION ON GRIDLINE

CENTER PARTITION ON MULLION

10 21 13 TOILET PARTITIONS

TOP OF SHAFT LID ASSEMBLY - REF DETAIL B4/0AI507

CONC CURB W/ PEDESTRIAN TRAFFIC COATING WRAP - REF D3/0AI516

LIGHTING INVERTER CABINET - REF ELEC DWGS

ELEVATOR SUMP PUMP CONTROL PANEL - REF PLUMB DWGS

100.

101.

102.

103.

104.

105.

106.

107.

108.

109.

110.

111.

112.

113.

114.

115.

116.

117.

118.

119.

120.

121.

122.

123.

124.

125.

126.

127.

128.

129.

130.

131.

132.

133.

134.

135.

136.

137.

138.

139.

140.

141.

142.

143.

144.

145.

146.

147.

148.

149.

FLOOR PLAN SHEET NOTE SERIES BEGINS WITH NOTE 100

NOT ALL SHEET NOTES APPEAR ON EVERY SHEET

1XX

1. REFER TO SHEET 0AI002 FOR PARTITION SCHEDULE AND GENERAL

PARTITION TYPE NOTES.

2. REFER TO AI400 SERIES FOR ENLARGED FLOOR PLAN VIEWS INCLUDING

MEDICAL EQUIPMENT NOT SHOWN IN AI100 SERIES PLANS.

3. REFER TO LIFESAFETY DRAWINGS (LS SERIES) FOR CAMPUS-WIDE

SCOPE OF RATED WALL CONSTRUCTION, SMOKE PARTITIONS, SUITE

DESIGNATIONS AND EXIT DISCHARGE INFORMATION.

4. PARTITION TYPES AS NOTED BY THE SYMBOL CONTINUE BETWEEN

ROOM/SPACE CORNERS OR ANY INTERSECTING PARTITION.

5. DIFFERING PARTITION TYPES SHALL ALIGN SO THAT WALL PLANES

CONTINUE UNBROKEN WITHIN/ACROSS ROOMS AND/OR SPACES.

6. UNLESS OTHERWISE NOTED, DIMENSIONS ARE TO FINISH FACE.

7. REFER TO AI600 SERIES DRAWINGS FOR DOOR & RELITE SCHEDULES.

8. DISTANCE FROM HINGE SIDE OF DOOR TO INTERSECTING STUD WALL

SHALL BE 4" UNLESS NOTED OR DETAILED OTHERWISE (MEASURED

FROM OUTSIDE OF FRAME).

9. CONTRACTOR SHALL VERIFY ALL DIMENSIONS NOTED AS "CLEAR" OR

"MIN". DIMENSIONS NOTED AS "HOLD" ARE CRITICAL TO COORDINATE

OTHER WORK (E.G. CEILING GRIDS, LIGHTING, FINISHES).

10. CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO INITIATING

CONSTRUCTION AND REPORT DISCREPENCIES TO ARCHITECT PRIOR TO

COMMENCING WORK.

11. CONTRACTOR SHALL PROVIDE ALL BLOCKING REQUIRED TO ANCHOR

ALL WALL AND CLG MOUNTED ITEMS, INCLUDING BUT NOT LIMITED TO

TOILET ROOM ACCESSORIES, MILLWORK, CASEWORK, HANDRAILS,

DOOR STOPS ETC...

12. FIRE STOPPING SYSTEMS - REFER TO SPEC SECTION 07 84 00 FOR INFO

REGARDING PENETRATIONS OF ALL RATED ASSEMBLIES (BOTH SINGLE

AND DOUBLE MEMBRANE PENETRATIONS) INCLUDING BUT NOT LIMITED

TO PENETRATIONS FOR DUCTWORK, CONDUIT, PIPING AND SUPPORT

FOR WALL MOUNTED EQUIPMENT, CABINETS AND COUNTERTOPS.

13. UP-SWING GRAB BAR IN-WALL SUPPORT - SEE DTLS C3 AND A3 SHEET

0AI506 FOR TUBE STEEL BACKING AT ALL UP-SWING GRAB BARS.

14. SEE DETAIL A3/0AI516 FOR COLUMN BASE WATERPROOFING AT

EXPOSED COLUMNS IN SERVICE BAYS & MECHANICAL ROOMS.

15. SHIELDING REQUIREMENTS - VERIFY ALL SHIELDING REQUIREMENTS

WITH FINAL EQUIPMENT SELECTIONS AND A VA APPROVED REGISTERED

PHYSICIST PRIOR TO COMMENCING WORK IN SHIELDED-ROOM AREAS.

16. HOUSEKEEPING AND COPY ROOMS - ALL PARTITIONS TO BE FULL

HEIGHT TO UNDERSIDE OF DECK/INTERSTITIAL ABOVE. SEE PARTITION

TYPE NOTES SHEET 0AI002.

FLOOR PLAN SHEET NOTES

KEY PLAN

FLOOR PLAN LEGEND

ROOM NUMBER

REFERENCE ROOM NUMBER:

REFERENCE ROOM NUMBER INDICATES ROOM TO

REFERENCE FOR TYPICAL MEDICAL EQUIPMENT LAYOUT,

INTERIOR ELEVATION TAGS, GENERAL ANNOTATION AND

DIMENSIONS UNLESS OTHERWISE NOTED.

NOT ALL SYMBOLS/NOTES APPEAR ON EVERY SHEET

WHERE SYMBOL REFERENCES ANOTHER DRAWING SERIES,

SYMBOL IS SHOWN FOR DESIGN/DIMENSIONAL COORDINATION

ONLY. REFERENCE THE ENGINEERING DRAWINGS FOR FULL

SCOPE OF DEVICE LOCATIONS & ASSOCIAITED SPECIFICATIONS.

LEAD

RF

XXXX

1X

EMI

REF:XXXX

FD

CR

FEC

FEC_20

FEW

HVC

EXX-X

LKR-XX

PB

IA

FA/PS

SEE SHIELDING DETAILS/SCHEDULES ON SHEET 0AI514

LEAD SHIELDING

RADIOFREQUENCY SHIELDING

ELECTROMAGNETIC INTERFERENCE SHIELDING

MAGNETIC SHIELDING

07 95 13 - INTERIOR EXPANSION JOINT COVER ASSEMBLY -

"XX-X" LETTER DESIGNATION INDICATES COVER TYPE PER SHEET

0AI517. REFERENCE FIRE/SMOKE RATED CONDITIONS AS

INDICATED BY ASSOCIATED PTN TYPES ON THE FLOOR PLANS.

LOCKERS: "XX" DESIGNATION INDICATES TYPE:

2A - 10 51 13 - DBL TIER METAL LOCKERS, SLOPED TOP

12"W X 15"D X 60"H

LOCKERS PAINTED TO MATCH ADJ WALL

REF DTL D2/0AI532

2A.1 - 10 51 13 - DBL TIER METAL LOCKERS, SLOPED TOP

12"W X 15"D X 60"H

LOCKERS PAINTED TO MATCH ADJ WALL

REF DTL E2/0AI532

2B - 10 51 23 - DBL TIER "Z" PLAM LOCKERS, W/ PLAM SOFFIT

12"W X 15"D X 80"H

FINISH: PLAM-10

REF DTL E2/0AI532

TOPS OF LOCKERS TO ALIGN AT 7'-0" AFF.

FOR REFERENCE ONLY - GENERAL LOCATION OF OPEN OFFICE

FURNITURE - SEE FURNITURE DWGS FOR EXACT TYPES AND

LOCATIONS.

CARD READER - REF LOW VOLTAGE DWGS

DOOR PUSH PLATE - REF LOW VOLTAGE DWGS

PANIC ALARM BUTTON - REF LOW VOLTAGE DWGS

INFORMATION ASSIST CALL BOX - REF LOW VOLTAGE DWGS

FIRE ALARM PULL STATION - REF FIRE ALARM DWGS

10 44 13 - FIRE EXTINGUISHER CABINETS

RECESSED CABINET SIZED TO HOLD 10# ABC EXTINGUISHER

RECESSED CABINET SIZED TO HOLD 20# CO2 EXTINGUISHER

WALL MOUNTED EXTINGUISHER LOCATION

FIRE DEPARTMENT HOSE VALVE CABINET - REF FIRE PROT. DWGS

FLOOR DRAIN - REF PLUMBING DWGS

WHERE DRAIN IS NOT SET IN DEPRESSED SLAB/SLOPED

FLOOR SYSTEM; SET DRAIN 1/2" BELOW FINISH FLOOR

LEVEL AND TAPER CONC. AND FLOORING TO FLUSH W/

DRAIN STRAINER IN A 2' RADIUS FROM CENTER OF DRAIN

FLOOR OUTLET - REF ELECTRICAL DWGS

FLOOR CLEAN OUT - REF PLUMBING DWGS.

MAG

FCO

DASHED OBJECTS WITH EQUIPMENT TAG INDICATE

MEDICAL/OFFICE EQUIPMENT. REFERENCE EQUIPMENT

ACTIVIATION REPORT - SEE SPECIFICATIONS SECTION

01 11 10 FOR LOCATION OF REPORT.

X1234

XX1234

DP

TOILET WITH WALL MOUNTED UP-SWING GRAB BARS

10 28 00

SEE SHEET 0AI201 FOR GRAB BAR MOUNTING

HEIGHTS AND DIMENSIONAL LAYOUT

TOILET WITH WALL MOUNTED GRAB BARS

10 28 00

SEE SHEET 0AI201 FOR GRAB BAR MOUNTING

HEIGHTS AND DIMENSIONAL LAYOUT

XXXXX

PARTITION TYPE TAG - REF PARTITION SCHEDULE SHT 0AI002

RELITE TAG - REF FRAME SCHEDULE SHEET 0AI600

DOOR TAG - REF DOOR SCHEDULES AI600 SERIES

XAI40X

A

DB

C

INTERIOR ELEVATION REFERENCE:

INTERIOR ELEVATION CALLOUT

SHEET ON WHICH ELEVATION IS DRAWN

XAI10X

XAI10Y MATCHLINE REFERENCE

CENTERLINE TAG

SPOT ELEVATIONEL: +10'-0"

DIMENSIONS SAME AS LEVEL 02 AREA B2 UON

INTERIOR BACK-UP WALL, OPENINGS, SOFFITS, ETC

AROUND PERIMETER OF BUILDING REVISED TO

COORDINATE W/ EWP-06 SKIN COST REDUCTIONS. NEW

AND/OR REVISED PLAN/SECTION/RCP DETAILS AS

INDICATED ON PLANS AND REFLECTED CEILING PLANS.

11 BULL 015A - PRE-AWARD 7/26/2013

12 BULL 015A - VE 7/26/2013

Refer to RFI 01551: Interior Wall Construction Clarification at Exterior Walls

RFI 01551.1 for Interior Wall Construction at Precast Walls

RFI 02197 - 1'-1" from back of precast to finish face of drywall

File details come from the government source that posted it. Updated .