Drawing 1.pdf
PDF 159 KB Posted
- Attached to
- Lenel Access Control System Federal contract opportunity
- Solicitation number
- FA282322Q0016
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Solicitation Amendment - FA282322Q00160001.pdf | ||
| Solicitation Amendment FA282322Q00160001 SF 30.pdf | ||
| Wage Determination.pdf | ||
| Drawing 2.pdf | ||
| Site Visit.pdf | ||
| Solicitation - FA282322Q0016.pdf | ||
| SSJ_Redacted.pdf | ||
| SOW 4.1.22.pdf | ||
| Request Base Access.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
111A 2.1
SAW BUNKER
J
113B 1.2
113A 2.1
LATHE BUNKER
J
EG
LI
N
AI
R
FO
RC
E
BA
SE
, F
LO
RI
DA
AD
VA
N C
ED
M
U N
IT
IO
N S
TE
C
H N
O
LO
G Y
C O
M
PL
EX
P
H
AS
E
II
PR
O
JE
C
T N
O . F
TF
A0
M
O
BI
LE
D
IS
TR
IC
T
M O
BI
LE
, A
LA
BA
M
A
Mobile District
US Army Corps of Engineers ®
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
N O
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
SHEET
IDENTIFICATION
1 2 3 4 5
D
C
B
A
FILE:
DATE:
W
AR
D P
AR
KW
AY
KA
N
SA
S C
IT
Y, M O
BU
RN
S
M cD
O
NN
EL
L
D
ES
IG
N
ED
B
Y:
D R
AW
N
B Y:
SB
M
T
BY
PL
O
T
SC
AL
E:
SI
ZE
" x
4"
FI
LE
N
AM
E:
C
KD
B Y:
PL
O
T D
AT
E:
D
AT
E:
SO
LI
C
IT
AT
IO
N N
U M
BE
R
PR
O
JE
C
T N
U M
BE
R
C
AD
D C
O D
E:
W
8-
-R
-0
FT
FA
M
EF
FTFA043000
JU
N
E, JU
N
E, 6/22/2020 3:38:57 PM
1/ 4"
'-0
C.
PL
UM
M
ER
A.
S
NE
TH
EN
P.
OG
OR
M
AN
12276407-EY1020050
-0
7-
EY
Ap pr ov er
07-EY102
SE
C
U R
IT
Y
AN
D
S
AF
ET
Y
SY
ST
EM
PL
AN
S
-B U
N
KE
R
C
AP
E, E
XP
LO
SI
VE
M
AC
H
IN
IN
G
SCALE: 1/4" = 1'-0"C1 SECURITY AND SAFETY SYSTEM PLAN - SAW BUNKER
SCALE: 1/4" = 1'-0"C2 SECURITY AND SAFETY SYSTEM PLAN - LATHE BUNKER
0 2' 4' 8' 0 2' 4' 8'
KEYED NOTES:
BMS FOR "SAFETY INTERLOCK SYSTEM". CONDUITS
SHALL RUN TO ROOM AS INDICATED.
MUSHROOM PUSHBUTTON FOR USER CONTROL
SYSTEM. PROVIDE 2-#12 WIRES BACK TO CONTROL
ROOM INDICATED FOR USER CONNECTIONS TO
CONTROL RACK.
BMS SHALL BE SUITABLE AS AN INTRINSICALLY SAFE
DEVICE.
PROVIDE 12"H x 12"W x 4"D WALL-MOUNTED JUNCTION
BOX (JUNCTION BOX 1, SEE DETAIL ON SHEET 07-E-200
FOR LOCATION) FOR ALL SECURITY AND SAFETY
SYSTEM CONDUIT AND CABLING.
CAMERA MOUNT, SEE STRUCTURAL DRAWINGS.
COORDINATE CONDUIT ROUTING WITH LOCATION OF
CONDUIT SLEEVE IN WALL.
DEVICES SHALL BE INSTALLED ON EXTERIOR OF THIS
DOOR. ACS EQUIPMENT SHALL BE INSTALLED IN
LOCKABLE WELDED WEATHER PROOF ENCLOSURE
N N
GENERAL NOTES:
1.
2.
3.
4.
5.
6.
7.
ROUGH-IN AND RACEWAYS WITH PULL STRINGS
SHALL BE PROVIDED FOR FUTURE CABLING AND
ACTIVE EQUIPMENT BY OTHERS.
REFERENCE 01-EY-500 SERIES DRAWINGS FOR
DETAILS OF ROUGH-IN REQUIREMENTS FOR DOORS.
EXTERIOR DOORS ARE PROVISIONED FOR ALARMS,
ALONG WITH CONDUITS FOR CAMERA PROVISIONS.
CONDUITS FOR IDS/ACS ROUGH-INS SHALL ROUTE TO
WIREWAY AT BUILDING ENTRY AS INDICATED. ALL
OTHER BMS AND CAMERA LOCATIONS INDICATED
ARE FOR USER CONTROL SYSTEMS, CONDUITS
SHALL BE ROUTED TO ROOM INDICATED.
CAMERA ROUGH-INS SHALL PROVIDE 4X4 BACKBOX
(RATED FOR LOCATION BEING INSTALLED) AND 3/4"
CONDUIT TO COMMUNICATIONS ROOM OR LOCATION
AS INDICATED.
JUNCTION BOXES INSTALLED IN OUTSIDE BUNKERS
FOR CONNECTION TO USER INSTALLED CONTROL
RACKS SHALL BE SIZED BASED ON CONDUIT ENTRIES
BUT IN NO CASE SHALL BE LESS THAN A "4X4" BOX.
ALL JUNCTION BOXES INSTALLED SHALL HAVE BLANK
STAINLESS STEEL COVER INSTALLED.
LINEWORK (IF SHOWN) DOES NOT DENOTE CONDUIT
ROUTING. CONTRACTOR SHALL ROUTE CONDUITS
PER NOTES ON 07-E-100.
7 7
121A
121B 1.2
1 Gal BP1
BUNKER
J
123B 1.2
FEM BUNKER
123A 2.1
J
125B 1.2
125A 2.1
WEIGHING
BUNKER
J
EG
LI
N
AI
R
FO
RC
E
BA
SE
, F
LO
RI
DA
AD
VA
N C
ED
M
U N
IT
IO
N S
TE
C
H N
O
LO
G Y
C O
M
PL
EX
P
H
AS
E
II
PR
O
JE
C
T N
O . F
TF
A0
M
O
BI
LE
D
IS
TR
IC
T
M O
BI
LE
, A
LA
BA
M
A
Mobile District
US Army Corps of Engineers ®
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
N O
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
SHEET
IDENTIFICATION
1 2 3 4 5
D
C
B
A
FILE:
DATE:
W
AR
D P
AR
KW
AY
KA
N
SA
S C
IT
Y, M O
BU
RN
S
M cD
O
NN
EL
L
D
ES
IG
N
ED
B
Y:
D R
AW
N
B Y:
SB
M
T
BY
PL
O
T
SC
AL
E:
SI
ZE
" x
4"
FI
LE
N
AM
E:
C
KD
B Y:
PL
O
T D
AT
E:
D
AT
E:
SO
LI
C
IT
AT
IO
N N
U M
BE
R
PR
O
JE
C
T N
U M
BE
R
C
AD
D C
O D
E:
W
8-
-R
-0
FT
FA
M
EF
FTFA043000
JU
N
E, JU
N
E, 6/22/2020 4:51:05 PM
1/ 4"
'-0
C.
PL
UM
M
ER
A.
S
NE
TH
EN
P.
OG
OR
M
AN
12276408-EY1010050
-0
8-
EY
08-EY101
SE
C
U R
IT
Y
AN
D
S
AF
ET
Y
SY
ST
EM
PL
AN
S
C
AP
E, A
D
VA
N C
ED
P
R O
C
ES
SI
N
G
SCALE: 1/4" = 1'-0"C1 SECURITY AND SAFETY SYSTEM PLAN - 1 Gal BP 1 BUNKER
SCALE: 1/4" = 1'-0"A3 SECURITY AND SAFETY SYSTEM PLAN - FEM BUNKER
SCALE: 1/4" = 1'-0"A1 SECURITY AND SAFETY SYSTEM PLAN - WEIGHING BUNKER
0 2' 4' 8'
0 2' 4' 8' 0 2' 4' 8'
N
NN
KEYED NOTES:
BMS FOR "SAFETY INTERLOCK SYSTEM" ONLY.
MUSHROOM PUSHBUTTON FOR USER CONTROL SYSTEM. PROVIDE
2-#12 WIRES BACK TO CONTROL ROOM INDICATED FOR USER
CONNECTIONS TO CONTROL RACK.
BMS SHALL BE SUITABLE AS AN INTRINSICALLY SAFE DEVICE.
PROVIDE 12"H x 12"W x 4"D WALL-MOUNTED JUNCTION BOX
(JUNCTION BOX 1, SEE DETAIL ON SHEET 07-E-200 FOR LOCATION)
FOR ALL SECURITY AND SAFETY SYSTEM CONDUIT AND CABLING.
CAMERA MOUNT, SEE STRUCTURAL DRAWINGS.
COORDINATE CONDUIT ROUTING WITH LOCATION OF CONDUIT
SLEEVE IN WALL.
DEVICES SHALL BE INSTALLED ON EXTERIOR OF THIS DOOR. ACS
EQUIPMENT SHALL BE INSTALLED IN LOCKABLE WELDED
WEATHER PROOF ENCLOSURE
GENERAL NOTES:
1. ROUGH-IN AND RACEWAYS WITH PULL STRINGS SHALL BE
PROVIDED FOR FUTURE CABLING AND ACTIVE EQUIPMENT BY
OTHERS.
REFERENCE 01-EY-500 SERIES DRAWINGS FOR DETAILS OF ROUGH-
IN REQUIREMENTS FOR DOORS.
EXTERIOR DOORS ARE PROVISIONED FOR ALARMS. CONDUITS FOR
IDS/ACS ROUGH-INS SHALL ROUTE TO WIREWAY AT BUILDING
ENTRY AS INDICATED.
CAMERA ROUGH-INS SHALL PROVIDE 4X4 BACKBOX (RATED FOR
LOCATION BEING INSTALLED) AND 3/4" CONDUIT TO
COMMUNICATIONS ROOM OR LOCATION AS INDICATED.
JUNCTION BOXES INSTALLED IN OUTSIDE BUNKERS FOR
CONNECTION TO USER INSTALLED CONTROL RACKS SHALL BE
SIZED BASED ON CONDUIT ENTRIES BUT IN NO CASE SHALL BE
LESS THAN A "4X4" BOX.
ALL JUNCTION BOXES INSTALLED SHALL HAVE BLANK STAINLESS
STEEL COVER INSTALLED.
LINEWORK (IF SHOWN) DOES NOT DENOTE CONDUIT ROUTING.
CONTRACTOR SHALL ROUTE CONDUITS PER NOTES ON 08-E-101
2.
3.
4.
5.
6.
7.
1 3
1 3
1 3
1 3
1 3
1 3
122A
122B 1.2
1 Gal BP2
BUNKER
J
124B 1.2
5 Gal BP BUNKER
J
124A 2.1
126A 2.1
126B 1.2
5 Gal RAM
BUNKER
J
EG
LI
N
AI
R
FO
RC
E
BA
SE
, F
LO
RI
DA
AD
VA
N C
ED
M
U N
IT
IO
N S
TE
C
H N
O
LO
G Y
C O
M
PL
EX
P
H
AS
E
II
PR
O
JE
C
T N
O . F
TF
A0
M
O
BI
LE
D
IS
TR
IC
T
M O
BI
LE
, A
LA
BA
M
A
Mobile District
US Army Corps of Engineers ®
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
N O
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
SHEET
IDENTIFICATION
1 2 3 4 5
D
C
B
A
FILE:
DATE:
W
AR
D P
AR
KW
AY
KA
N
SA
S C
IT
Y, M O
BU
RN
S
M cD
O
NN
EL
L
D
ES
IG
N
ED
B
Y:
D R
AW
N
B Y:
SB
M
T
BY
PL
O
T
SC
AL
E:
SI
ZE
" x
4"
FI
LE
N
AM
E:
C
KD
B Y:
PL
O
T D
AT
E:
D
AT
E:
SO
LI
C
IT
AT
IO
N N
U M
BE
R
PR
O
JE
C
T N
U M
BE
R
C
AD
D C
O D
E:
W
8-
-R
-0
FT
FA
M
EF
FTFA043000
JU
N
E, JU
N
E, 6/22/2020 4:51:08 PM
1/ 4"
'-0
C.
PL
UM
M
ER
A.
S
NE
TH
EN
P.
OG
OR
M
AN
12276408-EY1020050
-0
8-
EY
08-EY102
SE
C
U R
IT
Y
AN
D
S
AF
ET
Y
SY
ST
EM
PL
AN
S
C
AP
E, A
D
VA
N C
ED
P
R O
C
ES
SI
N
G
SCALE: 1/4" = 1'-0"C1 SECURITY AND SAFETY SYSTEM PLAN - 1 Gal BP 2 BUNKER
SCALE: 1/4" = 1'-0"A3 SECURITY AND SAFETY SYSTEM PLAN - 5 Gal BP BUNKER SCALE: 1/4" = 1'-0"A1 SECURITY AND SAFETY SYSTEM PLAN - 5 Gal RAM BUNKER
0 2' 4' 8'
0 2' 4' 8' 0 2' 4' 8'
NN
N
KEYED NOTES:
BMS FOR "SAFETY INTERLOCK SYSTEM". CONDUITS SHALL RUN
TO ROOM AS INDICATED.
MUSHROOM PUSHBUTTON FOR USER CONTROL SYSTEM.
PROVIDE 2-#12 WIRES BACK TO CONTROL ROOM INDICATED FOR
USER CONNECTIONS TO CONTROL RACK.
BMS SHALL BE SUITABLE AS AN INTRINSICALLY SAFE DEVICE.
PROVIDE 12"H x 12"W x 4"D WALL-MOUNTED JUNCTION BOX
(JUNCTION BOX 1, SEE DETAIL ON SHEET 07-E-200 FOR
LOCATION) FOR ALL SECURITY AND SAFETY SYSTEM CONDUIT
AND CABLING.
CAMERA MOUNT, SEE STRUCTURAL DRAWINGS.
COORDINATE CONDUIT ROUTING WITH LOCATION OF CONDUIT
SLEEVE IN WALL.
DEVICES SHALL BE INSTALLED ON EXTERIOR OF THIS DOOR. ACS
EQUIPMENT SHALL BE INSTALLED IN LOCKABLE WELDED
WEATHER PROOF ENCLOSURE
GENERAL NOTES:
1. ROUGH-IN AND RACEWAYS WITH PULL STRINGS SHALL BE
PROVIDED FOR FUTURE CABLING AND ACTIVE EQUIPMENT BY
OTHERS.
REFERENCE 01-EY-500 SERIES DRAWINGS FOR DETAILS OF
ROUGH-IN REQUIREMENTS FOR DOORS.
EXTERIOR DOORS ARE PROVISIONED FOR ALARMS. CONDUITS
FOR IDS/ACS ROUGH-INS SHALL ROUTE TO WIREWAY AT
BUILDING ENTRY AS INDICATED.
CAMERA ROUGH-INS SHALL PROVIDE 4X4 BACKBOX (RATED FOR
LOCATION BEING INSTALLED) AND 3/4" CONDUIT TO
COMMUNICATIONS ROOM OR LOCATION AS INDICATED.
JUNCTION BOXES INSTALLED IN OUTSIDE BUNKERS FOR
CONNECTION TO USER INSTALLED CONTROL RACKS SHALL BE
SIZED BASED ON CONDUIT ENTRIES BUT IN NO CASE SHALL BE
LESS THAN A "4X4" BOX.
ALL JUNCTION BOXES INSTALLED SHALL HAVE BLANK STAINLESS
STEEL COVER INSTALLED.
LINEWORK (IF SHOWN) DOES NOT DENOTE CONDUIT ROUTING.
CONTRACTOR SHALL ROUTE CONDUITS PER NOTES ON 08-E-101
2.
3.
4.
5.
6.
7.
1 3
1 3
1 3
1 3
1 3
1 3
File details come from the government source that posted it. Updated .