Drawing 1_2400001-PK01-DRC-01.pdf

PDF 2 MB Posted

Attached to
Westwood/Braun/Plante Moran - Exterior Door Replacement
Solicitation number
RFP-WES-250000001343-2
Issued by
Wayne County, Michigan

About this file

This file contains architectural drawings and specifications for a door and frame replacement project at multiple schools within the Westwood Community School District in Michigan, managed by Ghafari Associates. The project involves replacing door panels, frames, and hardware at Robichaud High School, Thorne Elementary School, Tomlinson Middle School, and Daly Elementary School. The drawings include detailed floor plans showing door locations, door schedules specifying materials and finishes, and technical specifications for door types, frame types, and installation requirements.

The technical specifications indicate that doors are to be 7'0" high with 1-3/4" thickness, utilizing hollow metal (HM) frames and panels with paint finish, or in some cases fiberglass reinforced plastic (FRP) doors with wood frames. Various glazing options are specified including full glass, half glass, narrow glass and double glass configurations. All materials must be approved by the owner prior to ordering and installation. The project includes both complete door/frame replacements and instances where existing frames will remain with only door panels being replaced. The scope includes requirements for patching and repairing walls and frames, coordinating card reader requirements, and meeting ADA manuverability standards.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROJECT TEAM

PROJECT DESCRIPTIONPROJECT NAME

DOOR, FRAME, AND HARDWARE REPLACEMENT IN EXISTING

OPENINGS FOR ALL FOUR SCHOOLS WITHIN THE WESTWOOD

COMMUNITY SCHOOL DISTRICT.

01 ROBICHAUD HIGH SCHOOL

3601 JANET STREET, DEARBORN HEIGHTS, MI 48125

02 THORNE ELEMENTARY SCHOOL

25251 ANNAPOLIS STREET, DEARBORN HEIGHTS, MI 48125

03 TOMLINSON MIDDLE SCHOOL

25912 ANNAPOLIS STREET, INKSTER, MI 48141

04 DALY ELEMENTARY SCHOOL

25824 MICHIGAN AVE., INKSTER, MI 48141

CITY SUBMITTALS

LIST OF CITY SUBMITTALS

NONE REQUIRED

PROJECT INFORMATION

G H

AF

AR

I A

SS

O C

IA

TE

S www.ghafari.com

DEARBORN, MI 48126-2736 USA

TEL +1.313.441.3000

17101 MICHIGAN AVENUE

2/ 7/ 1:

:1

AM

PROJECT NUMBER:2400001

ISSUED FOR:PK01 DOC REL 01 - IFB

ISSUE DATE:02/10/25

OWNER REVIEW - DOOR AND FRAME

REPLACEMENT

00-0-0

DRAWING INDEX - PROJECT

/1 0/ P K0 D O C R

EL

- I

FB

SHEET # SHEET TITLE

00 GENERAL INFORMATION

● GO0-00-00 COVER AND INDEX SHEET

73 ARCHITECTURAL ELEMENTS

● 01-AE1-01-00 ARCHITECTURAL FLOOR PLANS ROBICHAUD HIGH SCHOOL

● 02-AE1-01-00 ARCHITECTURAL FLOOR PLANS THORNE ELEMENTARY SCHOOL

● 03-AE1-01-00 ARCHITECTURAL FLOOR PLANS TOMLINSON MIDDLE SCHOOL

● 04-AE1-01-00 ARCHITECTURAL FLOOR PLANS DALY ELEMENTARY SCHOOL

● 01-AE7-00-01 ARCHITECTURAL SCHEDULES

● 02-AE7-00-01 ARCHITECTURAL SCHEDULES

● 03-AE7-00-01 ARCHITECTURAL SCHEDULES

● 04-AE7-00-01 ARCHITECTURAL SCHEDULES

BRAUN CONSTRUCTION GROUP

39395 WEST 12 MILE ROAD

FARMINGTON HILLS, MI 48331

WWW.BRAUNCG.COM

RO-24 RO-25

RO-18

RO-02

R O

-0 1C

RO-04

RO-03

RO-05

RO-06

RO-07

RO-E1

RO-08

RO-09B

R O

-0 1A

RO-10A

R O

-1 3B

RO-11

R O

-1 1.

R O

-1

RO-P2

RO-14 RO-15

RO-16A

RO-16B

RO-17B

RO-GH1

R O

-2 2A

RO-P3

RO-19

RO-20B

RO-D1

R O

-0 1D

R O

-0 1B

RO-09C

RO-09A

RO-10B

R O

-1 3A

R O

-1 3C

RO-17A

RO-17C

RO-20A

RO-20C

R O

-2 1B

R O

-2 1A

R O

-2 2B

RO-26

DRAWN BY

SHEET TITLE

PROJECT MANAGER

QUALCHECK

DESIGNED BY

PROJECT #

SHEET NUMBER

1"=1000'-0" 0 1000' 2000'

1"=500'-0" 0 500' 1000'

1"=400'-0" 0 400' 800'

1"=200'-0" 0 200' 400'

1"=100'-0" 0 100' 200'

1"=80'-0" 0 80' 160'

1"=60'-0" 0 60' 120'

1"=50'-0" 0 50' 100'

1"=40'-0" 0 40' 80'

1"=30'-0" 0 30' 60'

1"=20'-0" 0 20' 40'

1"=10'-0" 0 10' 20'

16"=1'-0"

0 16' 32'

32"=1'-0" 0 16' 32'

8"=1'-0"

0 8' 16'

16"=1'-0" 0 8' 16'

4"=1'-0"

0 4' 8'

8"=1'-0" 0 4' 8'

2"=1'-0"

0 2' 4'

4"=1'-0" 0 2' 4'

1"=1'-0" 0 1' 2'0 1' 2'

"=1'-0"1 21 1

32"=1'-0" 0 32' 64'

G H

AF

AR

I A

SS

O C

IA

TE

S

REGISTRATION SEAL

CONSULTANT INFORMATION

PACKAGE 01

DOOR PANEL,

FRAME, HARDWARE

REPLACEMENT

DEARBORN, MI 48126-2736 USA

TEL +1.313.441.3000

17101 MICHIGAN AVENUE

www.ghafari.com

2/ 7/

1:

:1

AM

2400001

J. DREWEK

A. NERI

01-AE1-01-00

A. WIELAND

R. BARRY

ARCHITECTURAL FLOOR

PLANS ROBICHAUD HIGH

SCHOOL

73-1-0

SCALE:

NORTH

1" = 20'-0"

FIRST FLOOR COMPOSITE PLAN

REV DATE DOC REL ## - DESCRIPTION

02/10/25 PK01 DOC REL 01 - IFB

A B C

2"

2"R

EF

ER

T

O S

C H

ED

U

LE

REFER TO

SCHEDULE

TYP.

2"R

EF

ER

T O

S C

H

ED

U

LE

REFER TO

SCHEDULE

TYP.

4"

D

G

2"R

EF

ER

T

O S

C H

ED

U

LE

REFER TO

SCHEDULE

TYP.

36" 36" 36"

E F

R

EF

ER

T

O S

C H

ED

U

LE

REFER TO

SCHEDULE84

36"

2"2"

REFER TO

SCHEDULE

36"

2" 2"

1'-0"

4"2"

MATCH

EXISTING

OPENING

REFER TO

SCHEDULE

36"

2" 2"

REFER TO

SCHEDULE84

36"

2"2"

4" R

EF

ER

T O

S C

H

ED

U

LE

REFER TO

SCHEDULE

36"

2"

2" R

EF

ER

T O

S C

H

ED

U

LE

REFER TO

SCHEDULE84

36"

REFER TO

SCHEDULE

36"

2" 2"2" 2" 2"

REFER TO

SCHEDULE

36"

REFER TO

SCHEDULE

36"

2"

R

EF

ER

T

O S

C H

ED

U

LE

REFER TO

SCHEDULE

TYP.

36"

4"

2"

MATCH

EXISTING

OPENING

2" 2"

6"

2"

R

EF

ER

T

O S

C H

ED

U

LE

2"

"2"

36"

REFER TO

SCHEDULE

36"

REFER TO

SCHEDULE

36"

REFER TO

SCHEDULE

36"

REFER TO

SCHEDULE

2" 2" 2" 6" 2" 2" 2" 6"

2"

14"

2"

MATCH EXISTING OPENING

H

2"

R

EF

ER

T

O S

C H

ED

U

LE

MATCH

EXISTING

OPENING

REFER TO

SCHEDULE

36"

2"

REFER TO

SCHEDULE

36"

2" 4"

2"

2"

J

NOTE: NEW STOREFRONT FRAMING AND PANEL MATERIAL TO MATCH

EXISITNG SYSTEM CONFIGURATION UNLESS NOTED OTHERWISE.

FG

FULL GLASS

FL

FLUSH

HG

HALF GLASS

3' -7

NG

NARROW

GLASS

3' -7

8"

DG

DOUBLE

GLASS

3' -9

DOOR AND FRAME GENERAL NOTES

1.

2.

3.

4.

5.

6.

OWNER TO REVIEW AND APPROVE ALL DOOR PANEL, FRAME AND

HARDWARE, AND STOREFRONT REPLACEMENTS PRIOR TO

ORDERING MATERIAL AND INSTALLATION.

ALL EXISITNG CONDITIONS OF DOOR OPENINGS SCHEDULED FOR

WORK TO BE VERIFIED IN FIELD PRIOR TO STARTING WORK.

ALL SALVAGED DOOR PANELS, FRAMES AND HARDWARE MATERIAL

TO BE TURNED OVER TO OWNER IF NOT TO BE REUSED /

REINSTALLED.

PATCH AND REPAIR ALL WALLS, LINTELS AND FRAMES TO REMAIN

FOLLOWING DEMOLITION WORK TO MATCH EXISTING, ADJACENT

CONSTRUCTION.

EXISTING DOOR OPENINGS LOCATED IN EXISTING STOREFRONT

TYPE FRAMING THAT ARE SELECTED FOR REPLACEMENT TO HAVE

ADJACENT STOREFRONT FRAMING AND PANELS MATERIAL

REPLACED IN WHOLE UNLESS NOTED OTHERWISE.

OWNER TO SELECT A PAINT FINISH FOR NEW DOOR FRAMES AND

PANELS.

7. REFER TO "PRIORITY" COLUMN FOR DESIGNATED PRIORITY LEVEL

ASSIGNMENT PER OWNER AND GENERAL CONTRACTORS

REQUIREMENTS. CONTRACTOR AND OWNER TO VERIFY.

DOOR SCHEDULE REMARKS

1.

2.

3.

4.

VERIFY WITH OWNER DOORS, HARDWARE AND FRAMES TO REMAIN.

DOOR SWING TO FLIP FROM EXISTING ORIENTATION TO MEET ADA

MANUVERABILITY REQUIREMENTS.

COORDINATE AND VERIFY CARD READER REQUIREMENS WITH

OWNER.

EXISTING STOREFRONT FRAMES TO REMAIN IF THEY ARE IN GOOD

CONDITION AND CAN BE PROTECTED AND REUSED WITH NEW

WORK. OWNER TO REVIEW AND APPROVE PRIOR TO STARTING

WORK.

5. DOOR FRAME TO REMAIN, TO BE REPAINTED. VERIFY COLOR

WITH OWNER. REPLACE DOOR AND HARDWARE ONLY.

6. DOOR FRAME, DOOR PANEL AND HARDWARE TO REMAIN. DOOR

PANEL TO BE REPAINTED. VERIFY COLOR WITH OWNER.

35"

REFER TO

SCHEDULE

35"

REFER TO

SCHEDULE

35"

REFER TO

SCHEDULE

35"

REFER TO

SCHEDULE

35"

REFER TO

SCHEDULE

35"

REFER TO

SCHEDULE VE

R

IF

Y

IN

F

IE

LD

VERIFY IN FIELDVERIFY IN FIELD

R

EF

ER

T

O S

C H

ED

U

LE

2"

2" 2"

NOTE: NEW STOREFRONT FRAMING AND PANEL MATERIAL TO MATCH EXISITNG SYSTEM CONFIGURATION UNLESS

NOTED OTHERWISE.

TY

P.

TYP.TYP.

FRP FRP

FRP FRP

FRP FRP

FRP

FRP FRP FRP FRP

FRP

GL-1GL-1

FRP

REFER TO SCHEDULE

R

EF

ER

T

O S

C H

ED

U

LE

VE

R

IF

Y

IN

F

IE

LD

V.

I.F

NOTE: NEW STOREFRONT FRAMING AND PANEL MATERIAL TO MATCH

EXISITNG SYSTEM CONFIGURATION UNLESS NOTED OTHERWISE.

2"

TY

P.

TYP.2"

FRP

DRAWN BY

SHEET TITLE

PROJECT MANAGER

QUALCHECK

DESIGNED BY

PROJECT #

SHEET NUMBER

1"=1000'-0" 0 1000' 2000'

1"=500'-0" 0 500' 1000'

1"=400'-0" 0 400' 800'

1"=200'-0" 0 200' 400'

1"=100'-0" 0 100' 200'

1"=80'-0" 0 80' 160'

1"=60'-0" 0 60' 120'

1"=50'-0" 0 50' 100'

1"=40'-0" 0 40' 80'

1"=30'-0" 0 30' 60'

1"=20'-0" 0 20' 40'

1"=10'-0" 0 10' 20'

16"=1'-0"

0 16' 32'

32"=1'-0" 0 16' 32'

8"=1'-0"

0 8' 16'

16"=1'-0" 0 8' 16'

4"=1'-0"

0 4' 8'

8"=1'-0" 0 4' 8'

2"=1'-0"

0 2' 4'

4"=1'-0" 0 2' 4'

1"=1'-0" 0 1' 2'0 1' 2'

"=1'-0"1 21 1

32"=1'-0" 0 32' 64'

G H

AF

AR

I A

SS

O C

IA

TE

S

REGISTRATION SEAL

CONSULTANT INFORMATION

PACKAGE 01

DOOR PANEL,

FRAME, HARDWARE

REPLACEMENT

DEARBORN, MI 48126-2736 USA

TEL +1.313.441.3000

17101 MICHIGAN AVENUE

www.ghafari.com

2/ 7/

1:

:1

AM

2400001

J. DREWEK

A. NERI

01-AE7-00-01

A. WIELAND

R. BARRY

ARCHITECTURAL

SCHEDULES

73-7-1

SCALE: 1/4" = 1'-0"

DOOR FRAME TYPES - MODIFIED

SCALE: 1/4" = 1'-0"

DOOR PANEL TYPES

DOOR AND FRAME TO BE REPLACED SCHEDULE - FIRST FLOOR

DOOR

NUMBER PRIORITY COMMENTS

EGRESS

DOOR

CARD

READER

HARDWARE

SET

DOOR PANEL FRAME

FIRE RATING

WIDTH

HEIGHT THICKNESS TYPE MATERIAL FINISH

GLAZING

TYPE MATERIAL FINISH TYPE

GLAZING

TYPEPANEL 1 PANEL 2

RO-02 3 Yes No 12 3' - 0" 3' - 0" 7' - 0" 1 3/4" FL HM PNT - HM PNT A - - RO-03 3 Yes No 12 3' - 0" 3' - 0" 7' - 0" 1 3/4" FL HM PNT - HM PNT A - - RO-04 3 3 Yes Yes 17.1 3' - 0" 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT E - - RO-05 3 2 Yes No 09.2 3' - 0" 0" 7' - 0" 1 3/4" FL HM PNT - HM PNT C - - RO-06 3 No No 15 3' - 0" 0" 7' - 0" 1 3/4" FL HM PNT - HM PNT C - - RO-07 3 No No 16 3' - 0" 3' - 0" 7' - 0" 1 3/4" FL HM PNT - HM PNT A - - RO-09A 1 3, 4 Yes Yes 17 3' - 0" 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT DETAIL #1 - - RO-09B 1 4 Yes No 14 3' - 0" 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT DETAIL #1 - - RO-09C 1 4 Yes No 14 3' - 0" 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT DETAIL #1 - - RO-10A 1 3 Yes Yes 18.1 3' - 0" 3' - 0" 7' - 0" 1 3/4" FL HM PNT - HM PNT D - - RO-10B 1 Yes No 04 3' - 0" 0" 7' - 0" 1 3/4" FL HM PNT - HM PNT D - - RO-11 3 Yes No 03 3' - 4" 0" 7' - 0" 1 3/4" FL HM PNT - HM PNT C - - RO-11.5 3 5 Yes No 03 3' - 4" 0" 7' - 0" 1 3/4" FL HM PNT - ALUM ANOD A - - RO-12 1 Yes No 03 3' - 4" 0" 7' - 0" 1 3/4" FL HM PNT - HM PNT A - - RO-13A 3 Yes No 09.3 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT F - RO-13B 3 Yes No 14 3' - 0" 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT F - - RO-13C 3 Yes No 09.1 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT F - RO-16A 1 3 Yes Yes 18 3' - 0" 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT E - - RO-17A 1 Yes No 09 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT A - RO-17B 1 Yes No 14.1 3' - 0" 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT A - - RO-17C 1 Yes No 06 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT A - RO-18 3 4 Yes No 03.1 3' - 0" 7' - 0" 1 3/4" FL HM PNT ALUM ANOD H RO-19 1 Yes No 03.1 3' - 0" 0" 7' - 0" 1 3/4" FL HM PNT - ALUM ANOD C - - RO-20A 1 Yes No 05 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT G - RO-20B 1 Yes No 11 3' - 0" 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT G - - RO-20C 1 Yes No 08 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT G - RO-25 3 6 Yes No 19 3' - 0" 7' - 0" FL HM PNT ALUM ANOD C RO-26 1 3 Yes Yes 18 3' - 4" 3' - 4" 7' - 0" 1 3/4" NG HM PNT GL-1 ALUM ANOD J - - RO-E1 3 Yes No 07 6' - 0" 0" 7' - 0" 1 3/4" FL HM PNT - HM PNT DETAIL #2 - -

DOOR AND FRAME SCHEDULE ABBREVIATIONS

ABBREVIATION DESCRIPTION

ALUM ALUMINUM

ANOD ANODIZED

EXIST EXISTING

FF FACTORY FINISH

FRP FIBERGLASS REINFORCED PLASTIC

GL GLASS

HM HOLLOW METAL

PNT PAINT

STL STEEL

STN STAIN

WD WOOD

REV DATE DOC REL ## - DESCRIPTION

02/10/25 PK01 DOC REL 01 - IFB

EXISTING TO REMAIN DOOR AND FRAME SCHEDULE - FIRST FLOOR

DOOR

NUMBER COMMENTS

EGRESS

DOOR

CARD

READER

HARDWARE

SET

DOOR PANEL FRAME

FIRE RATING

WIDTH

HEIGHT THICKNESS TYPE MATERIAL FINISH

GLAZING

TYPE MATERIAL FINISH TYPE

GLAZING

TYPEPANEL 1 PANEL 2

RO-01A 1 No Yes 01 3' - 0" 7' - 0" 1 3/4" DG EXIST EXIST EXIST EXIST EXIST EXIST - - RO-01B 1 Yes No 01 3' - 0" 7' - 0" 1 3/4" NG EXIST EXIST EXIST EXIST EXIST EXIST - RO-01C 1 Yes No 02 3' - 0" 3' - 0" 7' - 0" 1 3/4" NG EXIST EXIST EXIST EXIST EXIST EXIST - - RO-01D 1 Yes No 01 3' - 0" 7' - 0" 1 3/4" NG EXIST EXIST EXIST EXIST EXIST EXIST - RO-08 1 No No 01 3' - 0" 7' - 0" 1 3/4" AG EXIST EXIST EXIST EXIST EXIST EXIST RO-14 1 Yes No 01 3' - 4" 0" 7' - 0" 1 3/4" FL EXIST EXIST - EXIST EXIST EXIST - - RO-15 1 Yes No 01 3' - 4" 0" 7' - 0" 1 3/4" FL EXIST EXIST - EXIST EXIST EXIST - - RO-16B 1 Yes No 02 3' - 0" 3' - 0" 7' - 0" 1 3/4" NG EXIST EXIST EXIST EXIST EXIST EXIST - - RO-21A 1 Yes No 01 2' - 0" 7' - 0" 1 3/4" HG EXIST EXIST EXIST EXIST EXIST EXIST - RO-21B 1 Yes No 01 2' - 0" 7' - 0" 1 3/4" HG EXIST EXIST EXIST EXIST EXIST EXIST - RO-22A 1 Yes No 01 2' - 0" 7' - 0" 1 3/4" HG EXIST EXIST EXIST EXIST EXIST EXIST - RO-22B 1 Yes No 01 2' - 0" 7' - 0" 1 3/4" HG EXIST EXIST EXIST EXIST EXIST EXIST - RO-24 1 Yes No 01 3' - 0" 3' - 0" 6' - 10" 2" FG EXIST EXIST EXIST EXIST EXIST EXIST - RO-D1 1 No No 01 3' - 0" 7' - 0" 1 3/4" FG EXIST EXIST EXIST EXIST EXIST EXIST EXIST - RO-GH1 1 No No 01 3' - 0" 7' - 0" 1 3/4" FG EXIST EXIST EXIST EXIST EXIST EXIST EXIST - RO-P2 1 No No 02 3' - 0" 3' - 0" 7' - 0" 1 3/4" HG EXIST EXIST EXIST EXIST EXIST EXIST EXIST - RO-P3 1 Yes No 02 3' - 0" 3' - 0" 7' - 0" 1 3/4" HG EXIST EXIST EXIST EXIST EXIST EXIST EXIST -

SCALE: 1/4" = 1'-0"

1 STOREFRONT ELEVATION - DOOR RO-09

SCALE: 1/4" = 1'-0"

2 STOREFRONT ELEVATION - DOOR RO-E1

UP DN

UP

UP

TH-01D

TH-01C

TH-01B

TH-01A

TH-01H

TH-01G

TH-01F

TH-01E

TH-02B

TH-02A

TH-05B

TH-05A

TH-03 TH-03.5

TH-04

TH-06

TH-07A TH-07B

TH-07.5

TH-08

TH

-1

6B

TH-16C

TH-08.5

TH-14A

TH-14B

TH-13A

TH-11

TH-12

TH-15

TH-17

TH-18

TH-21

TH-22

TH-09

TH-10

TH-20

TH

-1

6A

TH-13B

TH-13C

TH-19

TH

-2

3B

TH

-2 3A

DEMO EXISTING DOORS,

FRAMES AND HARDWARE AND

TURN OVER TO OWNER. INFILL

OPENING TO MATCH EXISTING

ADJACENT CONSTRUCTION.

DRAWN BY

SHEET TITLE

PROJECT MANAGER

QUALCHECK

DESIGNED BY

PROJECT #

SHEET NUMBER

1"=1000'-0" 0 1000' 2000'

1"=500'-0" 0 500' 1000'

1"=400'-0" 0 400' 800'

1"=200'-0" 0 200' 400'

1"=100'-0" 0 100' 200'

1"=80'-0" 0 80' 160'

1"=60'-0" 0 60' 120'

1"=50'-0" 0 50' 100'

1"=40'-0" 0 40' 80'

1"=30'-0" 0 30' 60'

1"=20'-0" 0 20' 40'

1"=10'-0" 0 10' 20'

16"=1'-0"

0 16' 32'

32"=1'-0" 0 16' 32'

8"=1'-0"

0 8' 16'

16"=1'-0" 0 8' 16'

4"=1'-0"

0 4' 8'

8"=1'-0" 0 4' 8'

2"=1'-0"

0 2' 4'

4"=1'-0" 0 2' 4'

1"=1'-0" 0 1' 2'0 1' 2'

"=1'-0"1 21 1

32"=1'-0" 0 32' 64'

G H

AF

AR

I A

SS

O C

IA

TE

S

REGISTRATION SEAL

CONSULTANT INFORMATION

PACKAGE 01

DOOR PANEL,

FRAME, HARDWARE

REPLACEMENT

DEARBORN, MI 48126-2736 USA

TEL +1.313.441.3000

17101 MICHIGAN AVENUE

www.ghafari.com

2/ 7/

1:

:2

AM

2400001

J. DREWEK

A. NERI

02-AE1-01-00

A. WIELAND

R. BARRY

ARCHITECTURAL FLOOR

PLANS THORNE

ELEMENTARY SCHOOL

73-1-0

REV DATE DOC REL ## - DESCRIPTION

1 02/10/25 PK01 DOC REL 01 - IFB

SCALE:

NORTH

1/16" = 1'-0"

FIRST FLOOR COMPOSITE PLAN

A B

2"R

EF

ER

T

O S

C H

ED

U

LE

REFER TO

SCHEDULE

TYP.

2"R

EF

ER

T O

S C

H

ED

U

LE

REFER TO

SCHEDULE

TYP.

4"

E

2"R

EF

ER

T

O S

C H

ED

U

LE

REFER TO

SCHEDULE

TYP.

36" 36" 36"

2"

REFER TO

SCHEDULE

TYP.

36"

2"

REFER TO

SCHEDULE

TYP.

36"

2" 2"

MATCH

EXISTING

OPENING

D

2"R

EF

ER

T

O S

C H

ED

U

LE

REFER TO

SCHEDULE

TYP.

36"

2"

REFER TO

SCHEDULE

TYP.

36"

2"

TYP.

2" 2"

MATCH

EXISTING

OPENING

F

2"R

EF

ER

T

O S

C H

ED

U

LE

REFER TO

SCHEDULE

TYP.

36"

2"

REFER TO

SCHEDULE

TYP.

36"

2"

TYP.

2" 2"

MATCH

EXISTING

OPENING

G

2"R

EF

ER

T

O S

C H

ED

U

LE

REFER TO

SCHEDULE

TYP.

36"

2"

REFER TO

SCHEDULE

TYP.

36"

2"

TYP.

2" 2"

MATCH

EXISTING

OPENING

4"

C

2"R

EF

ER

T

O S

C H

ED

U

LE

REFER TO

SCHEDULE

TYP.

36"

2"

2"

H

R

EF

ER

T

O S

C H

ED

U

LE

REFER TO

SCHEDULE84

36"

2"

REFER TO

SCHEDULE

36"

2"

2"

2" 2"

1'-0"

J

2"R

EF

ER

T

O S

C H

ED

U

LE

REFER TO

SCHEDULE

TYP.

36"

2"

REFER TO

SCHEDULE

TYP.

36"

2"

TYP.

2"

MATCH

EXISTING

OPENING

REFER TO

SCHEDULE

36"

2"

REFER TO

SCHEDULE

TYP.

36"

2"

TYP.

LV

LOUVER

(BOTTOM)

FL

FLUSH

HG

HALF GLASS

3' -7

NG

NARROW

GLASS

3' -7

8"

3' -9

DG

DOUBLE

GLASS

DOOR AND FRAME GENERAL NOTES

1.

2.

3.

4.

5.

6.

OWNER TO REVIEW AND APPROVE ALL DOOR PANEL, FRAME AND

HARDWARE, AND STOREFRONT REPLACEMENTS PRIOR TO

ORDERING MATERIAL AND INSTALLATION.

ALL EXISITNG CONDITIONS OF DOOR OPENINGS SCHEDULED FOR

WORK TO BE VERIFIED IN FIELD PRIOR TO STARTING WORK.

ALL SALVAGED DOOR PANELS, FRAMES AND HARDWARE MATERIAL

TO BE TURNED OVER TO OWNER IF NOT TO BE REUSED /

REINSTALLED.

PATCH AND REPAIR ALL WALLS, LINTELS AND FRAMES TO REMAIN

FOLLOWING DEMOLITION WORK TO MATCH EXISTING, ADJACENT

CONSTRUCTION.

EXISTING DOOR OPENINGS LOCATED IN EXISTING STOREFRONT

TYPE FRAMING THAT ARE SELECTED FOR REPLACEMENT TO HAVE

ADJACENT STOREFRONT FRAMING AND PANELS MATERIAL

REPLACED IN WHOLE UNLESS NOTED OTHERWISE.

OWNER TO SELECT A PAINT FINISH FOR NEW DOOR FRAMES AND

PANELS.

7. REFER TO "PRIORITY" COLUMN FOR DESIGNATED PRIORITY LEVEL

ASSIGNMENT PER OWNER AND GENERAL CONTRACTORS

REQUIREMENTS. CONTRACTOR AND OWNER TO VERIFY.

DOOR SCHEDULE REMARKS

1.

2.

3.

4.

VERIFY WITH OWNER DOORS, HARDWARE AND FRAMES TO REMAIN.

DOOR SWING TO FLIP FROM EXISTING ORIENTATION TO MEET ADA

MANUVERABILITY REQUIREMENTS.

COORDINATE AND VERIFY CARD READER REQUIREMENS WITH

OWNER.

EXISTING STOREFRONT FRAMES TO REMAIN IF THEY ARE IN GOOD

CONDITION AND CAN BE PROTECTED AND REUSED WITH NEW

WORK. OWNER TO REVIEW AND APPROVE PRIOR TO STARTING

WORK.

5. DOOR FRAME TO REMAIN, TO BE REPAINTED. VERIFY COLOR

WITH OWNER. REPLACE DOOR AND HARDWARE ONLY.

6. DOOR FRAME, DOOR PANEL AND HARDWARE TO REMAIN. DOOR

PANEL TO BE REPAINTED. VERIFY COLOR WITH OWNER.

NOTE: NEW STOREFRONT FRAMING AND PANEL

MATERIAL TO MATCH EXISITNG SYSTEM

CONFIGURATION UNLESS NOTED OTHERWISE.

REFER TO SCHEDULE

R

EF

ER

T

O S

C H

ED

U

LE

VE

R

IF

Y

IN

F

IE

LD

2" TY

P.

TY

P.

2"

2"

FRP

GL-1

FRP

LOUVER

D O

O R

O

PE

N

IN

G

CURTAIN WALL

FRAMING

CURTAIN WALL

DOOR

VE

R

IF

Y

1/

2"

4"

7 13/16"

1-5/16" INSULATED

LAMINATED GLASS

CURTAIN WALL

DOOR STOP

CURTAIN WALL

SUB-FRAME

1-5/16" INSULATED

LAMINATED GLASS

DOOR OPENING

CURTAIN WALL FRAMING

CURTAIN WALL DOOR

VERIFY

2 1/2"

3/4"5"

1-5/16" INSULATED

LAMINATED GLASS

/1 6"

CURTAIN WALL DOOR STOP

CURTAIN WALL SUB-FRAME

1-5/16" INSULATED

LAMINATED GLASS

INTERIOR EXTERIOR

SILL

METAL DOOR

THRESHOLD, SET

IN SEALANT

1-5/16" INSULATED

LAMINATED GLASS

CONCRETE FLOOR

SLAB, REFER TO

STRUCTURAL

CURTAIN WALL

DOOR

CONCRETE EXTERIOR

SUPPORTED SLAB,

REFER TO

STRUCTURAL

DOOR BOTTOM

SWEEP, REFER TO

HARDWARE SET

SLOPE

2"

1 5/16"

5/

2"

2"

1 5/16"

DRAWN BY

SHEET TITLE

PROJECT MANAGER

QUALCHECK

DESIGNED BY

PROJECT #

SHEET NUMBER

1"=1000'-0" 0 1000' 2000'

1"=500'-0" 0 500' 1000'

1"=400'-0" 0 400' 800'

1"=200'-0" 0 200' 400'

1"=100'-0" 0 100' 200'

1"=80'-0" 0 80' 160'

1"=60'-0" 0 60' 120'

1"=50'-0" 0 50' 100'

1"=40'-0" 0 40' 80'

1"=30'-0" 0 30' 60'

1"=20'-0" 0 20' 40'

1"=10'-0" 0 10' 20'

16"=1'-0"

0 16' 32'

32"=1'-0" 0 16' 32'

8"=1'-0"

0 8' 16'

16"=1'-0" 0 8' 16'

4"=1'-0"

0 4' 8'

8"=1'-0" 0 4' 8'

2"=1'-0"

0 2' 4'

4"=1'-0" 0 2' 4'

1"=1'-0" 0 1' 2'0 1' 2'

"=1'-0"1 21 1

32"=1'-0" 0 32' 64'

G H

AF

AR

I A

SS

O C

IA

TE

S

REGISTRATION SEAL

CONSULTANT INFORMATION

PACKAGE 01

DOOR PANEL,

FRAME, HARDWARE

REPLACEMENT

DEARBORN, MI 48126-2736 USA

TEL +1.313.441.3000

17101 MICHIGAN AVENUE

www.ghafari.com

2/ 7/

1:

:3

AM

2400001

J. DREWEK

A. NERI

02-AE7-00-01

A. WIELAND

R. BARRY

ARCHITECTURAL

SCHEDULES

73-7-1

SCALE: 1/4" = 1'-0"

DOOR FRAME TYPES

SCALE: 1/4" = 1'-0"

DOOR PANEL TYPES

DOOR AND FRAME SCHEDULE ABBREVIATIONS

ABBREVIATION DESCRIPTION

ALUM ALUMINUM

ANOD ANODIZED

EXIST EXISTING

FF FACTORY FINISH

FRP FIBERGLASS REINFORCED PLASTIC

GL GLASS

HM HOLLOW METAL

PNT PAINT

STL STEEL

STN STAIN

WD WOOD

REV DATE DOC REL ## - DESCRIPTION

1 02/10/25 PK01 DOC REL 01 - IFB

DOOR AND FRAME TO BE REPLACED SCHEDULE - FIRST FLOOR

DOOR

NUMBER PRIORITY COMMENTS

EGRESS

DOOR

CARD

READER

HARDWARE

SET

DOOR PANEL FRAME

FIRE RATING

WIDTH

HEIGHT THICKNESS TYPE MATERIAL FINISH

GLAZING

TYPE MATERIAL FINISH TYPE

GLAZING

TYPEPANEL 1 PANEL 2

TH-01A 1 3 Yes Yes 09.2 3' - 0" 7' - 0" 1 3/4" HG HM PNT GL-1 ALUM ANOD J TH-01B 1 Yes No 06 3' - 0" 7' - 0" 1 3/4" HG HM PNT GL-1 ALUM ANOD J TH-01C 1 Yes No 06 3' - 0" 7' - 0" 1 3/4" HG HM PNT GL-1 ALUM ANOD J TH-01D 1 Yes No 06 3' - 0" 7' - 0" 1 3/4" HG HM PNT GL-1 ALUM ANOD J TH-02A 1 Yes No 09 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT F TH-02B 1 Yes No 06.1 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT F TH-03 3 No No 15.2 3' - 4" 0" 7' - 0" 1 3/4" FL HM PNT - HM PNT DETAIL #1 - -

TH-03.5 3 EQUIPPED

WITH

LOUVER

No No 07 3' - 6" 0" 7' - 0" 1 3/4" LV HM PNT - HM PNT C - -

TH-04 3 No No 15 3' - 6" 0" 7' - 0" 1 3/4" FL HM PNT - HM PNT A - - TH-05A 1 Yes No 06.1 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT F TH-05B 1 3 Yes Yes 09.5 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT F TH-06 1 Yes No 09.3 3' - 0" 0" 7' - 0" 1 3/4" FL HM PNT - HM PNT A - - TH-07.5 1 Yes No 07.1 3' - 0" 0" 7' - 0" 1 3/4" FL HM PNT - HM PNT A - - TH-07A 1 No Yes 15.1 3' - 4" 0" 7' - 0" 1 3/4" FL HM PNT - HM PNT A - - TH-07B 1 No No 01 3' - 0" 3' - 0" 7' - 0" 1 3/4" FL ALUM ANOD - ALUM ANOD A - - TH-08 1 3 Yes Yes 17 3' - 0" 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT A - - TH-09 3 Yes No 09.4 3' - 4" 0" 7' - 0" 1 3/4" FL HM PNT - HM PNT A - - TH-10 3 Yes No 09.1 3' - 4" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT B - TH-14A 2 4 Yes No 09.4 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT G TH-14B 2 4 Yes No 06.1 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT G TH-15 1 3 Yes Yes 17.1 3' - 0" 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT D - - TH-17 1 Yes No 12 3' - 0" 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT D - - TH-18 1 Yes No 06.2 3' - 0" 0" 7' - 0" 1 3/4" FL HM PNT - HM PNT A - - TH-19 1 Yes No 06.2 3' - 0" 0" 7' - 0" 1 3/4" FL HM PNT - HM PNT A - - TH-20 3 No No 15.3 3' - 0" 0" 7' - 0" 1 3/4" FL HM PNT - HM PNT A - - TH-21 3 No No 15.3 3' - 0" 0" 7' - 0" 1 3/4" FL HM PNT - HM PNT A - - TH-22 1 3,4 Yes Yes 17.2 3' - 0" 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT H - - TH-23A 1 3,4 Yes Yes 09.6 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT B TH-23B 1 4 Yes No 06.1 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT B

EXISTING TO REMAIN DOOR AND FRAME SCHEDULE - FIRST FLOOR

DOOR

NUMBER COMMENTS

EGRESS

DOOR

CARD

READER

HARDWARE

SET

DOOR PANEL FRAME

FIRE RATING

WIDTH

HEIGHT THICKNESS TYPE MATERIAL FINISH

GLAZING

TYPE MATERIAL FINISH TYPE

GLAZING

TYPEPANEL 1 PANEL 2

TH-01E 1 Yes No 01 3' - 0" 7' - 0" 1 3/4" DG EXIST EXIST EXIST EXIST EXIST EXIST TH-01F 1 Yes No 01 3' - 0" 7' - 0" 1 3/4" DG EXIST EXIST EXIST EXIST EXIST EXIST TH-01G 1 Yes No 01 3' - 0" 7' - 0" 1 3/4" DG EXIST EXIST EXIST EXIST EXIST EXIST TH-01H 1 Yes No 01 3' - 0" 7' - 0" 1 3/4" DG EXIST EXIST EXIST EXIST EXIST EXIST TH-08.5 1 No No 01 3' - 4" 0" 7' - 0" 1 3/4" FL EXIST EXIST EXIST EXIST EXIST - - TH-11 1 Yes No 01 3' - 0" 7' - 0" 1 3/4" NG EXIST EXIST EXIST EXIST EXIST EXIST - TH-12 1 Yes No 01 3' - 0" 7' - 0" 1 3/4" NG EXIST EXIST EXIST EXIST EXIST EXIST - TH-13A 1 Yes No 01 3' - 0" 7' - 0" NG EXIST EXIST EXIST EXIST EXIST TH-13B 1 Yes No 01 3' - 0" 7' - 0" NG EXIST EXIST EXIST EXIST EXIST TH-13C 1 Yes No 01 3' - 0" 7' - 0" NG EXIST EXIST EXIST EXIST EXIST TH-16A 1 Yes No 01 3' - 0" 7' - 0" 1 3/4" DG EXIST EXIST EXIST EXIST EXIST TH-16B 1 Yes No 01 3' - 0" 7' - 0" 1 3/4" DG EXIST EXIST EXIST EXIST EXIST TH-16C 1 Yes No 02 3' - 0" 3' - 0" 7' - 0" 1 3/4" HG EXIST EXIST EXIST EXIST EXIST - -

SCALE: 1/4" = 1'-0"

1 STOREFRONT ELEVATION - DOOR TH-03

SCALE: 3" = 1'-0"

2 STOREFRONT DOOR DETAILS - TYPICAL

TM-04B TM-04A

TM-02A

TM-02B

TM-03

TM-01B

TM-01A

TM-01C

TM-11B

TM-11A

TM

-0

5A

TM

-0

5C

TM

-0

5B

TM-08 TM-09

TM-11

TM-10

TM-07

DRAWN BY

SHEET TITLE

PROJECT MANAGER

QUALCHECK

DESIGNED BY

PROJECT #

SHEET NUMBER

1"=1000'-0" 0 1000' 2000'

1"=500'-0" 0 500' 1000'

1"=400'-0" 0 400' 800'

1"=200'-0" 0 200' 400'

1"=100'-0" 0 100' 200'

1"=80'-0" 0 80' 160'

1"=60'-0" 0 60' 120'

1"=50'-0" 0 50' 100'

1"=40'-0" 0 40' 80'

1"=30'-0" 0 30' 60'

1"=20'-0" 0 20' 40'

1"=10'-0" 0 10' 20'

16"=1'-0"

0 16' 32'

32"=1'-0" 0 16' 32'

8"=1'-0"

0 8' 16'

16"=1'-0" 0 8' 16'

4"=1'-0"

0 4' 8'

8"=1'-0" 0 4' 8'

2"=1'-0"

0 2' 4'

4"=1'-0" 0 2' 4'

1"=1'-0" 0 1' 2'0 1' 2'

"=1'-0"1 21 1

32"=1'-0" 0 32' 64'

G H

AF

AR

I A

SS

O C

IA

TE

S

REGISTRATION SEAL

CONSULTANT INFORMATION

PACKAGE 01

DOOR PANEL,

FRAME, HARDWARE

REPLACEMENT

DEARBORN, MI 48126-2736 USA

TEL +1.313.441.3000

17101 MICHIGAN AVENUE

www.ghafari.com

2/ 7/

1:

:1

AM

2400001

J. DREWEK

A. NERI

03-AE1-01-00

A. WIELAND

R. BARRY

ARCHITECTURAL FLOOR

PLANS TOMLINSON

MIDDLE SCHOOL

73-1-0

REV DATE DOC REL ## - DESCRIPTION

1 02/10/25 PK01 DOC REL 01- IFB

SCALE:

NORTH

1/8" = 1'-0"

A

2"R

EF

ER

T O

S C

H

ED

U

LE

REFER TO

SCHEDULE

TYP.

B

2"R

EF

ER

T

O S

C H

ED

U

LE

REFER TO

SCHEDULE

TYP.

36" 36"

REFER TO

SCHEDULE

36"

REFER TO

SCHEDULE

36"

2"

MATCH

EXISTING

OPENING

C

R

EF

ER

T

O S

C H

ED

U

LE

REFER TO

SCHEDULE84

36"

REFER TO

SCHEDULE

36"

2"

MATCH

EXISTING

OPENING

2"

TYP.

TY

P.

2"

TY

P.

TY

P.

TY

P.

NOTE: NEW STOREFRONT FRAMING AND PANEL MATERIAL TO MATCH

EXISITNG SYSTEM CONFIGURATION UNLESS NOTED OTHERWISE.

FL

FLUSH

NG

NARROW

GLASS

3' -7

8"

FG

FULL

GLASS

FGA

FULL

GLASS ARC

DOOR AND FRAME GENERAL NOTES

1.

2.

3.

4.

5.

6.

OWNER TO REVIEW AND APPROVE ALL DOOR PANEL, FRAME AND

HARDWARE, AND STOREFRONT REPLACEMENTS PRIOR TO

ORDERING MATERIAL AND INSTALLATION.

ALL EXISITNG CONDITIONS OF DOOR OPENINGS SCHEDULED FOR

WORK TO BE VERIFIED IN FIELD PRIOR TO STARTING WORK.

ALL SALVAGED DOOR PANELS, FRAMES AND HARDWARE MATERIAL

TO BE TURNED OVER TO OWNER IF NOT TO BE REUSED /

REINSTALLED.

PATCH AND REPAIR ALL WALLS, LINTELS AND FRAMES TO REMAIN

FOLLOWING DEMOLITION WORK TO MATCH EXISTING, ADJACENT

CONSTRUCTION.

EXISTING DOOR OPENINGS LOCATED IN EXISTING STOREFRONT

TYPE FRAMING THAT ARE SELECTED FOR REPLACEMENT TO HAVE

ADJACENT STOREFRONT FRAMING AND PANELS MATERIAL

REPLACED IN WHOLE UNLESS NOTED OTHERWISE.

OWNER TO SELECT A PAINT FINISH FOR NEW DOOR FRAMES AND

PANELS.

7. REFER TO "PRIORITY" COLUMN FOR DESIGNATED PRIORITY LEVEL

ASSIGNMENT PER OWNER AND GENERAL CONTRACTORS

REQUIREMENTS. CONTRACTOR AND OWNER TO VERIFY.

DOOR SCHEDULE REMARKS

1.

2.

3.

4.

VERIFY WITH OWNER DOORS, HARDWARE AND FRAMES TO REMAIN.

DOOR SWING TO FLIP FROM EXISTING ORIENTATION TO MEET ADA

MANUVERABILITY REQUIREMENTS.

COORDINATE AND VERIFY CARD READER REQUIREMENS WITH

OWNER.

EXISTING STOREFRONT FRAMES TO REMAIN IF THEY ARE IN GOOD

CONDITION AND CAN BE PROTECTED AND REUSED WITH NEW

WORK. OWNER TO REVIEW AND APPROVE PRIOR TO STARTING

WORK.

5. DOOR FRAME TO REMAIN, TO BE REPAINTED. VERIFY COLOR

WITH OWNER. REPLACE DOOR AND HARDWARE ONLY.

6. DOOR FRAME, DOOR PANEL AND HARDWARE TO REMAIN. DOOR

PANEL TO BE REPAINTED. VERIFY COLOR WITH OWNER.

DRAWN BY

SHEET TITLE

PROJECT MANAGER

QUALCHECK

DESIGNED BY

PROJECT #

SHEET NUMBER

1"=1000'-0" 0 1000' 2000'

1"=500'-0" 0 500' 1000'

1"=400'-0" 0 400' 800'

1"=200'-0" 0 200' 400'

1"=100'-0" 0 100' 200'

1"=80'-0" 0 80' 160'

1"=60'-0" 0 60' 120'

1"=50'-0" 0 50' 100'

1"=40'-0" 0 40' 80'

1"=30'-0" 0 30' 60'

1"=20'-0" 0 20' 40'

1"=10'-0" 0 10' 20'

16"=1'-0"

0 16' 32'

32"=1'-0" 0 16' 32'

8"=1'-0"

0 8' 16'

16"=1'-0" 0 8' 16'

4"=1'-0"

0 4' 8'

8"=1'-0" 0 4' 8'

2"=1'-0"

0 2' 4'

4"=1'-0" 0 2' 4'

1"=1'-0" 0 1' 2'0 1' 2'

"=1'-0"1 21 1

32"=1'-0" 0 32' 64'

G H

AF

AR

I A

SS

O C

IA

TE

S

REGISTRATION SEAL

CONSULTANT INFORMATION

PACKAGE 01

DOOR PANEL,

FRAME, HARDWARE

REPLACEMENT

DEARBORN, MI 48126-2736 USA

TEL +1.313.441.3000

17101 MICHIGAN AVENUE

www.ghafari.com

2/ 7/

1:

:1

AM

2400001

J. DREWEK

A. NERI

03-AE7-00-01

A. WIELAND

R. BARRY

ARCHITECTURAL

SCHEDULES

73-7-1

SCALE: 1/4" = 1'-0"

DOOR FRAME TYPES

SCALE: 1/4" = 1'-0"

DOOR PANEL TYPES

DOOR AND FRAME SCHEDULE ABBREVIATIONS

ABBREVIATION DESCRIPTION

ALUM ALUMINUM

ANOD ANODIZED

EXIST EXISTING

FF FACTORY FINISH

FRP FIBERGLASS REINFORCED PLASTIC

GL GLASS

HM HOLLOW METAL

PNT PAINT

STL STEEL

STN STAIN

WD WOOD

REV DATE DOC REL ## - DESCRIPTION

1 02/10/25 PK01 DOC REL 01- IFB

DOOR AND FRAME TO BE REPLACED SCHEDULE - FIRST FLOOR

DOOR

NUMBER PRIORITY COMMENTS

EGRESS

DOOR

CARD

READER

HARDWARE

SET

DOOR PANEL FRAME

FIRE RATING

WIDTH

HEIGHT THICKNESS TYPE MATERIAL FINISH

GLAZING

TYPE MATERIAL FINISH TYPE

GLAZING

TYPEPANEL 1 PANEL 2

TM-03 1 3 Yes Yes 17 3' - 0" 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT C - - TM-04A 3 Yes No 09.1 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT C TM-04B 3 Yes No 04 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT C TM-05A 1 3 Yes Yes 09.3 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT B TM-05B 1 Yes No 06 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT B TM-05C 1 Yes No 06 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT B TM-07 1 Yes No 03 3' - 0" 0" 7' - 0" 1 3/4" FL HM PNT - HM PNT A - - TM-08 2 Yes No 09.4 3' - 0" 0" 7' - 0" 1 3/4" FL HM PNT - HM PNT A - - TM-09 2 No No 15 3' - 0" 0" 7' - 0" 1 3/4" FL HM PNT - HM PNT A - - TM-10 1 3 Yes Yes 17 3' - 0" 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT C - - TM-11 2 No No 07 3' - 0" 0" 7' - 0" 1 3/4" FL HM PNT - HM PNT A - - TM-11A 1 5 Yes No 09.5 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT A TM-11B 1 3,5 Yes Yes 09.2 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT A

EXISTING TO REMAIN DOOR AND FRAME SCHEDULE - FIRST FLOOR

DOOR

NUMBER COMMENTS

EGRESS

DOOR

CARD

READER

HARDWARE

SET

DOOR PANEL FRAME

WIDTH

HEIGHT THICKNESS TYPE MATERIAL FINISH

GLAZING

TYPE MATERIAL FINISH TYPEPANEL 1 PANEL 2

TM-01A 1,3 Yes No 01 3' - 0" 7' - 0" FGA EXIST EXIST EXIST EXIST EXIST EXIST TM-01B 1,3 Yes No 01 3' - 0" 7' - 0" FGA EXIST EXIST EXIST EXIST EXIST EXIST TM-01C 1 Yes No 02 3' - 0" 3' - 0" 7' - 0" 1 3/4" HG EXIST EXIST EXIST EXIST EXIST EXIST TM-02A 1 Yes No 01 3' - 0" 7' - 0" NG EXIST EXIST EXIST EXIST EXIST EXIST TM-02B 1 Yes No 01 3' - 0" 7' - 0" NG EXIST EXIST EXIST EXIST EXIST EXIST

UP

DA-15B

DA-01A

DA-01B

DA-15A

DA-03

DA-04

DA-05D

DA-05E

DA-05F

DA-05A

DA-05B

DA-05C

DA-06C

DA-06B

DA-06A

DA-07

DA-09DA-10

DA-08

DA-12

DA-11B

DA-11A

DA-14

DA-13

DA-02

EXISTING EXIT

SIGNS ABOVE

THESE SETS OF

DOORS TO BE

REMOVED.

DRAWN BY

SHEET TITLE

PROJECT MANAGER

QUALCHECK

DESIGNED BY

PROJECT #

SHEET NUMBER

1"=1000'-0" 0 1000' 2000'

1"=500'-0" 0 500' 1000'

1"=400'-0" 0 400' 800'

1"=200'-0" 0 200' 400'

1"=100'-0" 0 100' 200'

1"=80'-0" 0 80' 160'

1"=60'-0" 0 60' 120'

1"=50'-0" 0 50' 100'

1"=40'-0" 0 40' 80'

1"=30'-0" 0 30' 60'

1"=20'-0" 0 20' 40'

1"=10'-0" 0 10' 20'

16"=1'-0"

0 16' 32'

32"=1'-0" 0 16' 32'

8"=1'-0"

0 8' 16'

16"=1'-0" 0 8' 16'

4"=1'-0"

0 4' 8'

8"=1'-0" 0 4' 8'

2"=1'-0"

0 2' 4'

4"=1'-0" 0 2' 4'

1"=1'-0" 0 1' 2'0 1' 2'

"=1'-0"1 21 1

32"=1'-0" 0 32' 64'

G H

AF

AR

I A

SS

O C

IA

TE

S

REGISTRATION SEAL

CONSULTANT INFORMATION

PACKAGE 01

DOOR PANEL,

FRAME, HARDWARE

REPLACEMENT

DEARBORN, MI 48126-2736 USA

TEL +1.313.441.3000

17101 MICHIGAN AVENUE

www.ghafari.com

2/ 7/

1:

:5

AM

2400001

J. DREWEK

A. NERI

04-AE1-01-00

A. WIELAND

R. BARRY

ARCHITECTURAL FLOOR

PLANS DALY

ELEMENTARY SCHOOL

73-1-0

REV DATE DOC REL ## - DESCRIPTION

1 02/10/25 PK01 DOC REL 01 - IFB

SCALE:

NORTH

3/32" = 1'-0"

A

2"R

EF

ER

T

O S

C H

ED

U

LE

REFER TO

SCHEDULE

TYP.

D

2"R

EF

ER

T

O S

C H

ED

U

LE

REFER TO

SCHEDULE

TYP.

36" 36"

REFER TO

SCHEDULE

36"

REFER TO

SCHEDULE

36"

2"

MATCH

EXISTING

OPENING

E

R

EF

ER

T

O S

C H

ED

U

LE

REFER TO

SCHEDULE84

36"

REFER TO

SCHEDULE

36"

2"

MATCH

EXISTING

OPENING

2"

TYP.

TY

P.

2"

TY

P.

TY

P.

TY

P.

C

2"R

EF

ER

T

O S

C H

ED

U

LE

REFER TO

SCHEDULE

TYP.

36"

REFER TO

SCHEDULE

36"

REFER TO

SCHEDULE

36"

2"

TY

P.

B

2"R

EF

ER

T

O S

C H

ED

U

LE

REFER TO

SCHEDULE

TYP.

36"

2"

MATCH

EXISTING

OPENING

2"

NOTE: NEW STOREFRONT FRAMING AND PANEL MATERIAL TO MATCH

EXISITNG SYSTEM CONFIGURATION UNLESS NOTED OTHERWISE.

FL

FLUSH

HG

HALF GLASS

3' -7

NG

NARROW

GLASS

3' -7

8"

3' -9

DG

DOUBLE

GLASS

DOOR AND FRAME GENERAL NOTES

1.

2.

3.

4.

5.

6.

OWNER TO REVIEW AND APPROVE ALL DOOR PANEL, FRAME AND

HARDWARE, AND STOREFRONT REPLACEMENTS PRIOR TO

ORDERING MATERIAL AND INSTALLATION.

ALL EXISITNG CONDITIONS OF DOOR OPENINGS SCHEDULED FOR

WORK TO BE VERIFIED IN FIELD PRIOR TO STARTING WORK.

ALL SALVAGED DOOR PANELS, FRAMES AND HARDWARE MATERIAL

TO BE TURNED OVER TO OWNER IF NOT TO BE REUSED /

REINSTALLED.

PATCH AND REPAIR ALL WALLS, LINTELS AND FRAMES TO REMAIN

FOLLOWING DEMOLITION WORK TO MATCH EXISTING, ADJACENT

CONSTRUCTION.

EXISTING DOOR OPENINGS LOCATED IN EXISTING STOREFRONT

TYPE FRAMING THAT ARE SELECTED FOR REPLACEMENT TO HAVE

ADJACENT STOREFRONT FRAMING AND PANELS MATERIAL

REPLACED IN WHOLE UNLESS NOTED OTHERWISE.

OWNER TO SELECT A PAINT FINISH FOR NEW DOOR FRAMES AND

PANELS.

7. REFER TO "PRIORITY" COLUMN FOR DESIGNATED PRIORITY LEVEL

ASSIGNMENT PER OWNER AND GENERAL CONTRACTOR'S

REQUIREMENTS. CONTRACTOR AND OWNER TO VERIFY.

DOOR SCHEDULE REMARKS

1.

2.

3.

4.

VERIFY WITH OWNER DOORS, HARDWARE AND FRAMES TO REMAIN.

DOOR SWING TO FLIP FROM EXISTING ORIENTATION TO MEET ADA

MANUVERABILITY REQUIREMENTS.

COORDINATE AND VERIFY CARD READER REQUIREMENS WITH

OWNER.

EXISTING STOREFRONT FRAMES TO REMAIN IF THEY ARE IN GOOD

CONDITION AND CAN BE PROTECTED AND REUSED WITH NEW

WORK. OWNER TO REVIEW AND APPROVE PRIOR TO STARTING

WORK.

5. DOOR FRAME TO REMAIN, TO BE REPAINTED. VERIFY COLOR

WITH OWNER. REPLACE DOOR AND HARDWARE ONLY.

6. DOOR FRAME, DOOR PANEL AND HARDWARE TO REMAIN. DOOR

PANEL TO BE REPAINTED. VERIFY COLOR WITH OWNER.

DRAWN BY

SHEET TITLE

PROJECT MANAGER

QUALCHECK

DESIGNED BY

PROJECT #

SHEET NUMBER

1"=1000'-0" 0 1000' 2000'

1"=500'-0" 0 500' 1000'

1"=400'-0" 0 400' 800'

1"=200'-0" 0 200' 400'

1"=100'-0" 0 100' 200'

1"=80'-0" 0 80' 160'

1"=60'-0" 0 60' 120'

1"=50'-0" 0 50' 100'

1"=40'-0" 0 40' 80'

1"=30'-0" 0 30' 60'

1"=20'-0" 0 20' 40'

1"=10'-0" 0 10' 20'

16"=1'-0"

0 16' 32'

32"=1'-0" 0 16' 32'

8"=1'-0"

0 8' 16'

16"=1'-0" 0 8' 16'

4"=1'-0"

0 4' 8'

8"=1'-0" 0 4' 8'

2"=1'-0"

0 2' 4'

4"=1'-0" 0 2' 4'

1"=1'-0" 0 1' 2'0 1' 2'

"=1'-0"1 21 1

32"=1'-0" 0 32' 64'

G H

AF

AR

I A

SS

O C

IA

TE

S

REGISTRATION SEAL

CONSULTANT INFORMATION

PACKAGE 01

DOOR PANEL,

FRAME, HARDWARE

REPLACEMENT

DEARBORN, MI 48126-2736 USA

TEL +1.313.441.3000

17101 MICHIGAN AVENUE

www.ghafari.com

2/ 7/

1:

:5

AM

2400001

J. DREWEK

A. NERI

04-AE7-00-01

A. WIELAND

R. BARRY

ARCHITECTURAL

SCHEDULES

73-7-1

SCALE: 1/4" = 1'-0"

DOOR FRAME TYPES

SCALE: 1/4" = 1'-0"

DOOR PANEL TYPES

DOOR AND FRAME SCHEDULE ABBREVIATIONS

ABBREVIATION DESCRIPTION

ALUM ALUMINUM

ANOD ANODIZED

EXIST EXISTING

FF FACTORY FINISH

FRP FIBERGLASS REINFORCED PLASTIC

GL GLASS

HM HOLLOW METAL

PNT PAINT

STL STEEL

STN STAIN

WD WOOD

REV DATE DOC REL ## - DESCRIPTION

1 02/10/25 PK01 DOC REL 01 - IFB

DOOR AND FRAME TO BE REPLACED SCHEDULE - FIRST FLOOR

DOOR

NUMBER PRIORITY COMMENTS

EGRESS

DOOR

CARD

READER

HARDWARE

SET

DOOR PANEL FRAME

FIRE RATING

WIDTH

HEIGHT THICKNESS TYPE MATERIAL FINISH

GLAZING

TYPE MATERIAL FINISH TYPE

GLAZING

TYPEPANEL 1 PANEL 2

DA-01A 1 Yes No 09 3' - 0" 7' - 8 1/4" 1 3/4" NG HM PNT GL-1 HM PNT E DA-01B 1 Yes No 09.7 3' - 0" 7' - 8 1/4" 1 3/4" NG HM PNT GL-1 HM PNT E DA-02 1 Yes No 09.5 3' - 0" 0" 7' - 0" 1 3/4" FL HM PNT - HM PNT B - - DA-03 3 Yes No 09.6 3' - 0" 0" 7' - 0" 1 3/4" FL HM PNT - HM PNT A - - DA-05D 3 5 Yes No 20 3' - 0" 7' - 0" 1 3/4" HG HM PNT GL-1 HM PNT A - - DA-05E 3 5 Yes No 20 3' - 0" 7' - 0" 1 3/4" HG HM PNT GL-1 HM PNT A - - DA-05F 3 5 Yes No 20 3' - 0" 7' - 0" 1 3/4" HG HM PNT GL-1 HM PNT A - - DA-06A 3 Yes No 07.1 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT D - DA-06B 3 Yes No 04 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT D - DA-06C 3 Yes No 04 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT D - DA-07 3 Yes No 07.2 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT A - DA-08 3 Yes No 07.3 3' - 0" 0" 7' - 0" 1 3/4" FL HM PNT - HM PNT A - - DA-09 1 3 Yes Yes 09.4 4' - 0" 0" 7' - 0" 1 3/4" FL HM PNT - HM PNT A - - DA-10 2 Yes No 07.4 4' - 0" 0" 7' - 0" 1 3/4" FL HM PNT - HM PNT A - - DA-11A 1 Yes No 11.2 3' - 0" 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT C - - DA-11B 1 3 Yes Yes 09.2 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT C - DA-12 3 5 Yes No 10 3' - 0" 3' - 0" 7' - 0" 1 3/4" NG HM PNT GL-1 HM PNT A - - DA-13 3 3,7 Yes Yes 11.1 3' - 0" 3' - 0" 7' - 0" 1 3/4" NG FRP FRP GL-1 WD PNT A - - DA-14 3 7 Yes No 11 3' - 0" 3' - 0" 7' - 0" 1 3/4" NG FRP FRP GL-1 WD PNT A - -

EXISTING TO REMAIN DOOR AND FRAME SCHEDULE - FIRST FLOOR

DOOR

NUMBER COMMENTS

EGRESS

DOOR

CARD

READER

HARDWARE

SET

DOOR PANEL FRAME

WIDTH

HEIGHT THICKNESS TYPE MATERIAL FINISH

GLAZING

TYPE MATERIAL FINISH TYPEPANEL 1 PANEL 2

DA-04 1 Yes No 02 3' - 0" 3' - 0" 7' - 0" 1 3/4" NG EXIST EXIST EXIST EXIST EXIST EXIST DA-05A 1 Yes No 01 3' - 0" 7' - 0" 1 3/4" HG HM PNT GL-1 HM PNT A DA-05B 1 Yes No 01 3' - 0" 7' - 0" 1 3/4" HG HM PNT GL-1 HM PNT A DA-05C 1 Yes No 01 3' - 0" 7' - 0" 1 3/4" HG HM PNT GL-1 HM PNT A DA-15A 1 No Yes 01 3' - 0" 7' - 8 1/4" 1 3/4" DG EXIST EXIST EXIST EXIST EXIST EXIST DA-15B 1 No Yes 01 3' - 0" 7' - 8 1/4" 1 3/4" NG EXIST EXIST EXIST EXIST EXIST EXIST