Drawing 01W-AS140 - 506-21-202.pdf

PDF 1 MB Posted

Attached to
Z1DA--Replace Roofing B-1W 506-21-202 Federal contract opportunity
Solicitation number
36C25024B0033
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10

About this file

This document appears to be a composite roof plan for a roof replacement project at the Ann Arbor VA Medical Center under project number 220109. The drawing shows the square footage for various roof sections, including the 9th Floor Roof (N) at 2,942 SF, the 9th Floor Roof (S) at 9,068 SF, and the 11th Floor Machine Room Roof at 2,390 SF, among others. The total square footage for the roof replacement is 34,920 SF. The roof assembly details are provided, indicating the use of an asphalt-primed concrete deck, insulation, and a 0.60 mil EPDM membrane. The document also references a related federal contract opportunity, solicitation number 36C25024B0033, titled "Z1DA--Descoped Replace Roofing B1W 506-21-202", which is for the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10.

View the file

Other files for this federal contract opportunity

Show all 16

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

9TH FLOOR

ROOF

2,942 SF

(10TH FLOOR)

PENTHOUSE

ROOF

1,822 SF

(11TH FLOOR)

MACHINE

ROOM ROOF

2,390 SF

9TH FLOOR

ROOF

9,068 SF

7TH FLOOR

ROOF

1,312 SF

8TH FLOOR

ROOF

1,637 SF

7TH FLOOR

ROOF

1,343 SF

8TH FLOOR

ROOF

663 SF

4TH FLOOR

ROOF

2,311 SF

5TH FLOOR

PENTHOUSE

ROOF

2,449 SF

4TH FLOOR

ROOF

213 SF

7TH FLOOR

ROOF

1,381 SF

8TH FLOOR

ROOF

2,016 SF

8TH FLOOR

ROOF

2,047 SF

7TH FLOOR

ROOF

631 SF

8TH FLOOR

ROOF

640 SF

37' - 3"

45' - 9"

113' - 6"

5' - 6"

/2

11' - 6"

/2

17' - 0"61' - 1"55' - 11"

38' - 9" 19' - 9" 42' - 3" 3' - 6"

/2

/2

15' - 0" 47' - 1"

41' - 7" 52' - 0"

52' - 0" 41' - 7"

39' - 0"

39' - 0"39' - 1 1/4" 210' - 0 1/4"

38' - 3"

/2

/2

65' - 8 1/2"

/2

19' - 4 1/8" 19' - 7 7/8"

ELECTRICAL

ROOF (BELOW)

1,952 SF

7TH FLOOR (N):

-ASPHALT PRIMED CONCRETE DECK

- FULLY ADHERED

-1.0" ISO

-2.0" ISO

-TAPERED ISO

-0.60 mil EPDM

9TH FLOOR (N):

-ASPHALT PRIMED CONCRETE DECK

- FULLY ADHERED

-1.0" ISO

-1.5" ISO

-TAPERED ISO

-0.60 mil EPDM

4TH FLOOR (NE NEAR):

-ASPHALT PRIMED CONCRETE DECK

- FULLY ADHERED

-1.5" ISO

-2.0" ISO

-TAPERED ISO

-0.60 mil EPDM

11TH FLOOR MACHINE ROOM ROOF:

-ASPHALT PRIMED CONCRETE DECK

- FULLY ADHERED

-1.5" ISO

-2.0" ISO

-TAPERED ISO

-0.60 mil EPDM

ELECTRICAL ROOF (BELOW):

-METAL DECK

-1.0" ISO MECHANICALLY FASTENED

-1.5" ISO

-TAPERED ISO

-0.60 mil EPDM

8TH FLOOR ROOF (SSE):

-ASPHALT PRIMED CONCRETE DECK

- FULLY ADHERED

-1.5" ISO

-2.0" ISO

-TAPERED ISO

-0.60 mil EPDM

1ST FLOOR ROOF

133 SF

ROOF PLAN LEGEND

WHITE EPDM

BLACK EPDM

ROOF REPLACEMENT SQUARE FOOTAGE:

11TH FLOOR MACHINE ROOM ROOF 2,390 S.F.

10TH FLOOR PENTHOUSE ROOF 1,822 S.F.

9TH FLOOR ROOF (N) 2,942 S.F.

9TH FLOOR ROOF (S) 9,068 S.F.

8TH FLOOR ROOF (N) 1,637 S.F.

8TH FLOOR ROOF (NW) 633 S.F.

8TH FLOOR ROOF (WSW) 640 S.F.

8TH FLOOR ROOF (SSW) 2,047 S.F.

8TH FLOOR ROOF (SSE) 2,016 S.F.

7TH FLOOR ROOF (N) 1,312 S.F.

7TH FLOOR ROOF (NW) 1,343 S.F.

7TH FLOOR ROOF (SW) 631 S.F.

7TH FLOOR ROOF (SE) 1,381 S.F.

5TH FLOOR PENTHOUSE ROOF 2,449 S.F.

4TH FLOOR ROOF (NE NEAR) 2,311 S.F.

4TH FLOOR ROOF (NE EAST) 213 S.F.

1ST FLOOR ROOF (NE) 133 S.F.

ELECTRICAL ROOF (BELOW) 1,952 S.F.

TOTAL SQUARE FOOTAGE: 34,920 S.F.

ROOF CORE SAMPLE

-DATA SHOWN IS EXISTING

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

DWG. ___ OF 12

7GAE PROJECT NO.: 220109

Sprinkler:

600 E. Michigan Avenue, Suite B Kalamazoo, MI 49007 P: 269.927.0144 www.7GenAE.com

1635 Prince Street Alexandria, VA 22314 P: 202.617.8485 www.alliance.us.com

A

B C

DE

COMPOSITE ROOF PLAN ROOF REPLACEMENT

ANN ARBOR VAMC

220109

1W

PROJECT DIRECTOR

FEBRUARY 18, 2022 JD GN

100% BID

DOCUMENTS

01W-AS140

NORTH

SCALE: 1/16" = 1'-0"

COMPOSITE ROOF PLAN

NOTE: DIMENSIONS SHOWN ARE APPROXIMATE.

CONTRACTOR IS RESPONSIBLE FOR VERIFICATION

OF QUANTITIES USED IN THEIR BIDS.

Revisions: Date:

35% SCHEMATIC DESIGN 12/21/20

65% DESIGN DEVELOPMENT 02/19/21

65% DESIGN DEVELOPMENT RESUBMISSION 04/15/21

95% CONSTRUCTION DOCUMENTS 06/14/21

100% BID DOCUMENTS 02/18/22 JAMES F.

DERKS

ARCHITECT

NO.

36980

Bid Scope Areas

Deductive Alternates

Roof Area Prioritization Process Selections per David Gedraitis email dated 11/22/2023