DRAFT - Korea Area - Price Schedule.xlsx

XLSX spreadsheet 41 KB Posted

Attached to
Korea Area - Hazardous Waste Removal, Transportation, and Disposal
Solicitation number
SP450024R0005
Issued by

About this file

This document includes a draft performance work statement and sources sought notice for hazardous waste removal, transportation, and disposal services in Korea. The U.S. Defense Logistics Agency seeks these services for wastes regulated by Korea and the EPA located at U.S. military sites in Korea. The indefinite delivery indefinite quantity contract would have a 30-month base period and 30-month option period. Services include characterization, packaging, transportation, and final treatment and disposal of wastes in accordance with Korean and EPA standards. Interested firms must submit capabilities statements by January 15, 2024 demonstrating experience performing these services and identifying proposed treatment, storage, and disposal facilities. The contract type will be firm-fixed-price. No solicitation exists yet, only this sources sought to identify potential offerors in advance of a future solicitation.

View the file

Other files

File Type Posted
DRAFT - PWS - Korea Area.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PS LB 30 nov 23

PR # XX-BE-XXX (Korea) Price Schedule v(11132023/01)
Base PeriodOption Period
Base
CLINDescriptionBase
CLINEst. QtyU/MPriceBase AmountBase
CLINEst. QtyU/MPriceOption Period Amount
Base
CLINService CLINsBase
CLINEst. QtyU/MPriceBase AmountBase
CLINEst. QtyU/MPriceOption Period Amount
1400SAPerform sampling and analysis IAW Korean test methods and protocols to determine Waste Characteristics, i.e., Ignitability, Corrosivity, Reactivity, and Toxicity due to Toxic Metals and Organic Compounds. U.S. EPA standard test methods may be used as supplemental characterization methods for off-installation disposal. Provide a HWPS with applicable Korean Waste Code(s) and analytical report per PWS Section 3.20.1400SA30EA$0.0030EA$0.00
1401SAPerform sampling and analysis IAW Korean test methods and protocols to determine Total ROK Regulated Metals.1401SA20EA$0.0020EA$0.00
1402SAPerform sampling and analysis IAW Korean test methods and protocols to determine Total ROK Regulated Volatile Organic Compounds (VOCs).1402SA20EA$0.0020EA$0.00
1403SAPerform sampling and analysis IAW Korean test methods and protocols to determine Total ROK Regulated Semi-Volatile Organic Compounds (SVOCs).1403SA20EA$0.0020EA$0.00
1404SAPerform sampling and analysis IAW Korean test methods and protocols to determine ROK Regulated Halogenated Solvents.1404SA10EA$0.0010EA$0.00
1405SVPerform sampling and analysis IAW Korean test methods and protocols to determine ROK Regulated Herbicides.1405SV5EA$0.005EA$0.00
1406SAPerform sampling and analysis IAW Korean test methods and protocols to determine ROK Regulated Pesticides.1406SA5EA$0.005EA$0.00
1407SAPerform sampling and analysis IAW Korean test methods and protocols to determine ROK Regulated PCBs.1407SA5EA$0.005EA$0.00
1408SAPerform sampling and analysis IAW Korean test methods and protocols to determine ROK Regulated Asbestos.1408SA10EA$0.0010EA$0.00
1409SAPerform sampling and analysis IAW Korean test methods and protocols to determine Ignitability/Flashpoint.1409SA10EA$0.0010EA$0.00
1410SAPerform sampling and analysis IAW Korean test methods and protocols to determine Corrosivity/pH.1410SA10EA$0.0010EA$0.00
1002SVIndustrial Cleaning Services, Daily, Crew of Two (2) (See 3.1).1002SV122EA$0.00122EA$0.00
1003SVIndustrial Cleaning Services, Weekly, Crew of Two (2) (See 3.2).1003SV6EA$0.006EA$0.00
1004SVIndustrial Cleaning Services, Monthly, Crew of Two (2) (See 3.3).1004SV1EA$0.001EA$0.00
1007SVIndustrial Cleaning Services, Daily, Crew of Three (3) (See 3.4).1007SV3EA$0.003EA$0.00
1008SVIndustrial Cleaning Services, Weekly, Crew of Three (3) (See 3.5).1008SV2EA$0.002EA$0.00
1009SVIndustrial Cleaning Services, Monthly, Crew of Three (3) (See 3.6).1009SV1EA$0.001EA$0.00
1080SVSurcharge for Weekend Work, Daily, Crew of Two (2) (See 3.7).1080SV1EA$0.001EA$0.00
1081SVSurcharge for Weekend Work, Daily, Crew of Three (3) (See 3.8).1081SV1EA$0.001EA$0.00
1082SVSurcharge for Hydro/Water Blasting Work, Daily, Crew of Three (3) (See 3.9).1082SV1EA$0.001EA$0.00
1083SVSurcharge for Permit - Required Confined Space Work, Daily, Crew of Three (3) (See 3.10).1083SV1EA$0.001EA$0.00
1084SVSurcharge for Super Vacuum Truck Work, Daily, Crew of Three (3) (See 3.11).1084SV1EA$0.001EA$0.00
1095SV1-Business Day Expedite/Performance (See 1.2.11).1095SV1EA$0.001EA$0.00
1096SV3-Business Day Expedite/Performance (See 1.2.11).1096SV2EA$0.002EA$0.00
1097SV5-Business Day Expedite/Performance (See 1.2.11).1097SV2EA$0.002EA$0.00
1098SV10-Business Day Expedite/Performance (See 1.2.11).1098SV2EA$0.002EA$0.00
1099SVSurcharge for Expedited Commencement of ICS Work, Crew of Two-Three (2-3) (See 3.22).1099SV2EA$0.002EA$0.00
6310Overpack one or more smaller containers into a single, Contractor-provided 85- to 110-gallon overpack or salvage drum for Compliance (See 1.2.12).63102EA$0.002EA$0.00
6311Overpack one or more smaller containers into a single, Contractor provided 55-, 30-, 15, or 5-gallon overpack drum for Compliance (See 1.2.12).63112EA$0.002EA$0.00
6311AAPackage/repackage/loose pack into up to a 5-gallon USG-provided container (See 1.2.13 and 3.18).6311AA10EA$0.0010EA$0.00
6311BBPackage/repackage/loose pack into up to a 15-gallon USG-provided container ( (See 1.2.13 and 3.18).6311BB5EA$0.005EA$0.00
6311CCPackage/repackage/loose pack into up to a 30-gallon USG-provided container (See 1.2.13 and 3.18)6311CC17$0.0017$0.00
6311DDPackage/repackage/loose pack into up to a 55-gallon USG-provided container (See 1.2.13 and 3.18).6311DD54EA$0.0054EA$0.00
6311EEPackage/repackage/loose pack into up to a CYB, military tri-wall box, or equivalent size government provided container (See 1.2.13 and 3.18).6311EE18EA$0.0018EA$0.00
6321Provide and prepare lab packs consisting of small quantity chemicals using Contractor-provided container, up to 55 gallons. (See 3.18).6321109EA$0.00109EA$0.00
6322Provide and prepare lab packs consisting of small quantity chemicals using Contractor-provided container, up to 30 gallons. (See 3.18).632235EA$0.0035EA$0.00
6323Provide and prepare lab packs consisting of small quantity chemicals using Contractor-provided container, up to 15 gallons. (See 3.18).632310EA$0.0010EA$0.00
6324Provide and prepare lab packs consisting of small quantity chemicals using Contractor-provided container, up to 5 gallons. (See 3.18).632420EA$0.0020EA$0.00
6400AAPrepare Hazardous Waste Profile Sheet (HWPS). (See 3.14).6400AA30EA$0.0030EA$0.00
6503Provide Certificate of Destruction/Disposal (CD). (See 2.1).650312EA$0.0012EA$0.00
K70010ODS/Mixed Gas Extraction (See 3.16)K700102EA$0.002EA$0.00
Base
CLINContainers/SuppliesBase
CLINEst. QtyU/MPriceBase AmountBase
CLINEst. QtyU/MPriceOption Period Amount
1150SPProvide Container, 5 GL, poly DR, new, OPN, pail w/screw top UN 1H2/Y30/S1150SP75EA$0.001150SP75EA$0.00
1151SPProvide Container, 5 GL, poly DR, new, OPN, pail w/screw top, UN 1H2/Y30/S, 1EA=251151SP20EA$0.001151SP20EA$0.00
1200SPProvide Container, Metal Open-Top Drum, 10 GL, New, Unlined, Heavy Bolt Ring, 1 EA=1 Drum, 1A2/X120/S.1200SP50EA$0.001200SP50EA$0.00
1214SPProvide Container, 15 GL, poly DR, new, OPN, UN 1H2/Y100/S1214SP10EA$0.001214SP10EA$0.00
1328SPProvide Container, 30 GL, poly DR, new, CLO, UN 1H1/Y1.8/1001328SP100EA$0.001328SP100EA$0.00
1329SPProvide Container, 30 GL, poly DR, new, CLO, UN 1H1/Y1.8/100, 1EA=251329SP8EA$0.001329SP8EA$0.00
1330SPProvide Container, 30 GL, poly DR, new, OPN, lever lock ring, UN 1H2/Y180/S1330SP100EA$0.001330SP100EA$0.00
1331SPProvide Container, 30 GL, poly DR, new, OPN, lever lock ring, UN 1H2/Y180/S, 1EA=251331SP8EA$0.001331SP8EA$0.00
1402SPProvide Container, 55 GL, poly DR, new, OPN, UN 1H2/Y140/S1402SP20EA$0.001402SP20EA$0.00
1403SPProvide Container, 55 GL, poly DR, new, OPN, UN 1H2/Y140/S, 1EA=251403SP2EA$0.001403SP2EA$0.00
1404SPProvide Container, 55 GL, poly DR, new, OPN, LLR, UN 1H2/X200/S AND 1H2/Y250/S1404SP200EA$0.001404SP200EA$0.00
1405SPProvide Container, 55 GL, poly DR, new, OPN, LLR, UN 1H2X200/S AND 1H2/Y250/S, 1EA=251405SP72EA$0.001405SP72EA$0.00
1406SPProvide Container, 55 GL, poly DR, new, OPN, LLR, UN 1H2/X300/S AND 1H2/Y250/S1406SP20EA$0.001406SP20EA$0.00
1407SPProvide Container, 55 GL, poly DR, new, CLO, UN 1H1/Y1.9/1501407SP788EA$0.001407SP788EA$0.00
1408SPProvide Container, 55 GL, poly DR, new, OPN, UN 1H2/Y130/S1408SP80EA$0.001408SP80EA$0.00
1409SPProvide Container, 55 GL, metal DR, new, CLO, UN 1A1/X1.4/3001409SP50EA$0.001409SP50EA$0.00
1411SPProvide Container, 55 GL, metal DR, new, CLO, UN 1A1/X1.8/3001411SP97EA$0.001411SP97EA$0.00
1412SPProvide Container, 55 GL, metal DR, new, CLO, UN 1A1/X1.8/300, 1EA=251412SP16EA$0.001412SP16EA$0.00
1419SPProvide Container, 55 GL, metal DR, new, OPN, BLTRNG, UN 1A2/Y1.6/1501419SP100EA$0.001419SP100EA$0.00
1420SPProvide Container, 55 GL, metal DR, new, OPN, BLTRNG, UN 1A2/Y1.6/150, 1EA=251420SP16EA$0.001420SP16EA$0.00
1423SPProvide Container, 55 GL, metal DR, new, OPN, BLTRNG, DUAL, UN 1A2/Y1.5/175 AND 1A2/X430/S1423SP25EA$0.001423SP25EA$0.00
1424SPProvide Container, 55 GL, metal DR, new, OPN, BLTRNG, DUAL, UN 1A2/Y1.5/175 AND 1A2/X430/S, 1EA=251424SP2EA$0.001424SP2EA$0.00
1425SPProvide Container, 55 GL, metal DR, new, OPN, EP lined, BLTRNG, DUAL, UN 1A2/Y1.5/175 AND 1A2/X430/S1425SP5,368EA$0.001425SP5368EA$0.00
1641SPProvide Container, 275 GL, tote, poly, new, with pallet, UN 31HA1/Y1641SP53EA$0.001641SP53EA$0.00
1644SPProvide Container, 330 GL, tote, poly, new, with pallet, UN 31HA1/Y1644SP10EA$0.001644SP10EA$0.00
Base
CLINBatteries for Recycle/DisposalBase
CLINEst. QtyU/MPriceBase AmountBase
CLINEst. QtyU/MPriceOption Period Amount
BA01Alkaline Batteries, for Contractor's choice of recycling or disposal.

Physical State: Various.

Permissible USEPA Waste Codes: D002, D004-11.

Possible ROK Waste Codes: 514101.BA01C715,494LB$0.00BA01C715,494LB$0.00
BA04Lead Acid Batteries, Wet, Dry, or Gel Pack, for mandatory recycling.

Physical State: Various.

Permissible USEPA Waste Codes: D002, D004-11.

Possible ROK Waste Codes: 020106, 514103.BA04C73,173LB$0.00BA04C73,173LB$0.00
BA05Lithium Ion (Li-Ion) Batteries, for recycling or disposal.

Physical State: Solid.

Permissible USEPA Waste Codes: D002-11.

Possible ROK Waste Codes: 514102.BA05C725,480LB$0.00BA05C725,480LB$0.00
BA07Lithium Manganese (LiMn and Oxides thereof) Batteries, for recycling or disposal.

Physical State: Solid.

Permissible USEPA Waste Codes: D002-11.

Possible ROK Waste Codes: 514102.BA07C718,341LB$0.00BA07C718,341LB$0.00
BA08Lithium Sulfur Dioxide (LiSO2) Batteries, for Contractor's choice of recycling or disposal (See 2.6.1).

Physical State: Solid.

Possible ROK Waste Code(s): 514102.BA08C79,653LB$0.00BA08C79,653LB$0.00
BA10Lithium Batteries, Mixed Types, deactivated if applicable, for recycling or disposal. (See 2.6.1).

Physical State: Solid.

Permissible USEPA Waste Codes: D002-11.

Possible ROK Waste Code(s): 514102.BA10C72,185LB$0.00BA10C72,185LB$0.00
BA12Mercury (Hg) Batteries, for mandatory recycling.

Physical State: Various.

Permissible USEPA Waste Codes: D004-11.

Possible ROK Waste Code(s): 514102.BA12C738LB$0.00BA12C738LB$0.00
BA13Nickel Metal Hydride (NiMH) Batteries, Wet and Dry, for recycling or disposal.

Physical State: Various.

Permissible USEPA Waste Codes: D002, D004-11.

Possible ROK Waste Codes: 514102.BA13C74,076LB$0.00BA13C74,076LB$0.00
BA14Nickel-Cadmium (NiCd) Batteries, Wet and Dry, for recycling or disposal.

Physical State: Various.

Permissible USEPA Waste Codes: D002, D004-11.

Possible ROK Waste Codes: 514102.BA14C71,500LB$0.00BA14C71,500LB$0.00
BA15Silver-Zinc (AgZn) and Zinc Silver Oxide (ZnAgO) Batteries for recycling or disposal.

Physical State: Solid.

Permissible USEPA Waste Codes: D002, D004-11.

Possible ROK Waste Codes: 514101, 514102.BA15C7955LB$0.00BA15C7955LB$0.00
Base
CLINCorrosivesBase
CLINEst. QtyU/MPriceBase AmountBase
CLINEst. QtyU/MPriceOption Period Amount
CS01Corrosive Acids, Inorganic other than HF and HNO3.

Physical State: Liquid.

Permissible USEPA Waste Codes: D002, D004-11, Listed inorganics.

Possible ROK Waste Code(s): 020101, 020102, 020199.CS01C78,406LB$0.00CS01C78,406LB$0.00
CS04Corrosive Acids, Chromic (H2Cr04 ), Liquids, Solids, Sludges, Debris.

Physical State: Various.

Permissible USEPA Waste Codes: D001 (OX) D002, D004-11, Listed inorganics.

Possible ROK Waste Code(s): 010201, 010299, 020199.CS04C71,114LB$0.00CS04C71,114LB$0.00
CS08Corrosive Acids, Non-Fuming, <40% Hydrofluoric (HF) or <25% Nitric (HNO3).

Physical State: Liquid.

Permissible USEPA Waste Codes: D001 (OX), D002, D004-11, Listed inorganics.

Possible ROK Waste Code(s): 020103, 020104.CS08C72,785EA$0.00CS08C72,785EA$0.00
CS09Corrosive Acids, Fuming, >40% Hydrofluoric (HF) or >25% Nitric (HNO3). May include Red Fuming Nitric Acid (RFNA).

Physical State: Liquid.

Permissible USEPA Waste Codes: D001 (OX), D002, D004-11, Listed inorganics.

Possible ROK Waste Code(s): 020103, 020104.CS09C71,946LB$0.00CS09C71,946LB$0.00
CS10Corrosive Alkalines, Inorganic. No Ammonia/Amines.

Physical State: Liquid.

Permissible USEPA Waste Codes: D002, D004-11, Listed inorganics.

Possible ROK Waste Code(s): 020201, 020299.CS10C73,342EA$0.00CS10C73,342EA$0.00
CS12Corrosive Ammonia/Amines, Organic/Inorganic, Liquids, Sludges, Solids, Debris. Flashpoint >140°F.

Physical State: Various.

Permissible USEPA Waste Codes: D002, D004-11, Listed.

Possible ROK Waste Code(s): 020202, 020299.CS12C77,519LB$0.00CS12C77,519LB$0.00
CS13Corrosive Organic Acids or Bases, Liquids/Sludges/Solids/Debris, No Ammonia/Amines, Flashpoint >140°F.

Physical State: Various.

Permissible USEPA Waste Codes: D002, D004-11, Listed.

Possible ROK Waste Code(s): 020199, 020299.CS13C71,392LB$0.00CS13C71,392LB$0.00
CS14Corrosive Inorganic Acids or Bases with Debris and Free Liquids, No Ammonia/Amines, Non-Flammable, including broken lead acid batteries.

Physical State: Various.

Permissible USEPA Waste Codes: D002, D004-11, Listed inorganics.

Possible ROK Waste Code(s): 020106, 020199, 020299.CS14C71,392LB$0.00CS14C71,392LB$0.00
Base
CLINCompressed Gas Cylinders/CartridgesBase
CLINEst. QtyU/MPriceBase AmountBase
CLINEst. QtyU/MPriceOption Period Amount
CLIN Suffix Key

Maximum cylinder dimensions, not counting valve or handle:

ME = Lecture = 3" x 12" M1 = Small = 4" x 24" M2 = Medium = 12" x 36" M3 = Large = 16" x 56" Refer to Compressed Gas Cross-Reference Tab for list of gases.

CY01 Category 1 Compressed Gas Cylinders (CGC), Cartridges, Canisters and Vessels. Examples include argon, helium, nitrogen, oxygen, carbon dioxide. NO FIRE EXTINGUISHERS ELIGIBLE FOR CLIN CY14.

Physical State: Compressed or liquified gas.

Permissible USEPA Waste Codes dependant upon specific chemical.

Possible ROK Waste Code(s): As applicable to specific chemical.CY01ME35EA$0.00CY01ME35EA$0.00
CY01M1639EA$0.00CY01M1639EA$0.00
CY01M22,599EA$0.00CY01M22,599EA$0.00
CY01M3111EA$0.00CY01M3111EA$0.00
CY02Category 2 Compressed Gas Cylinders (CGC), Cartridges, Canisters and Vessels. Examples include butane, ethyl ether, heptane, propane. NO REFRIGERANTS ELIGIBLE FOR CLIN CY15.

Physical State: Compressed or liquified gas.

Permissible USEPA Waste Codes dependant upon specific chemical.

Possible ROK Waste Codes: As applicable to specific chemical.CY02ME17EA$0.00CY02ME17EA$0.00
CY02M119EA$0.00CY02M119EA$0.00
CY02M22EA$0.00CY02M22EA$0.00
CY02M32EA$0.00CY02M32EA$0.00
CY03Category 3 Compressed Gas Cylinders (CGC), Cartridges, Canisters and Vessels. Examples include chlorine, hydrogen chloride, hydrogen fluoride.

Physical State: Compressed or liquified gas.

Permissible USEPA Waste Codes dependant upon specific chemical.

Possible ROK Waste Codes: As applicable to specific chemical.CY03ME2EA$0.00CY03ME2EA$0.00
CY03M12EA$0.00CY03M12EA$0.00
CY04Category 4 Compressed Gas Cylinders (CGC), Cartridges, Canisters and Vessels. Examples include chloropropane, nitric oxide, parathion.

Physical State: Compressed or liquified gas.

Permissible USEPA Waste Codes dependant upon specific chemical.

Possible ROK Waste Codes: As applicable to specific chemical.CY04ME1EA$0.00CY04ME1EA$0.00
CY08Category 8 Compressed Gas Cylinders (CGC), Cartridges, Canisters and Vessels. Examples include liquified petroleum gases other than refrigerants. NO REFRIGERANTS ELIGIBLE FOR CLIN CY15.

Physical State: Compressed or liquified gas.

Permissible USEPA Waste Codes dependant upon specific chemical.

Possible ROK Waste Codes: As applicable to specific chemical.CY08ME1EA$0.00CY08ME1EA$0.00
CY08M11EA$0.00CY08M11EA$0.00
CY08M21EA$0.00CY08M21EA$0.00
CY08M31EA$0.00CY08M31EA$0.00
CY09Cylinders, Acetylene, Containing Asbestos, for Purge and Landfill.

Physical State: Compressed or liquified gas.

Permissible USEPA Waste Codes dependant upon specific chemical.

Possible ROK Waste Code(s): 070101, 070102.CY09M11EA$0.00CY09M11EA$0.00
CY09M238EA$0.00CY09M238EA$0.00
CY09M32EA$0.00CY09M32EA$0.00
CY10Cylinders, Acetylene, No Asbestos, for Recycle/Reuse.

Physical State: Compressed or liquified gas.

Permissible USEPA Waste Codes: D001.

Possible ROK Waste Codes: 519900.CY10M11EA$0.00CY10M11EA$0.00
CY10M21EA$0.00CY10M21EA$0.00
CY10M31EA$0.00CY10M31EA$0.00
CY12Cylinders, Flammable, AVGAS, Ether Gas/Diesel Starting, for Disposal or Recycle.

Physical State: Compressed or liquified gas.

Permissible USEPA Waste Codes dependant upon specific chemical.

Possible ROK Waste Codes: 519900.CY12ME530EA$0.00CY12ME530EA$0.00
CY13Cartridges, Inert Gas, for Disposal/Recycle/Reuse. Diameter up to 1", Length up to 6". "ME" = 1 EA Cartridge.

Physical State: Compressed gas.

Permissible USEPA Waste Codes: N/A.

Possible ROK Waste Codes: 519900.CY13ME56EA$0.00CY13ME56EA$0.00
CY14Fire Extinguisher, Non-Flammable, may contain non-toxic powder, compressed or liquified gas.

Physical State: Compressed or liquified gas.

Permissible USEPA Waste Code(s): N/A.

Possible ROK Waste Code(s): 514001, 514099.CY14M11,362EA$0.00CY14M11,362EA$0.00
CY14M22,788EA$0.00CY14M22,788EA$0.00
CY14M398EA$0.00CY14M398EA$0.00
CY15Refrigerants, various. Examples include R-22, R-134A, R-404A, R-410A, and 1,1,1,2,3,3,3-Heptafluoropropane (HFC-227ea).

Physical State: Compressed or liquified gas.

Permissible USEPA Waste Codes dependant upon specific chemical.

Possible ROK Waste Codes: 513701, 513702, 513703, 513704.CY15ME1EA$0.00CY15ME1EA$0.00
CY15M18EA$0.00CY15M18EA$0.00
CY15M210EA$0.00CY15M210EA$0.00
CY15M36EA$0.00CY15M36EA$0.00
Base
CLINFlammable/Combustible/IgnitableBase
CLINEst. QtyU/MPriceBase AmountBase
CLINEst. QtyU/MPriceOption Period Amount
FL01Aerosols, Flammable/Combustible/Ignitable, non-foaming. No isocyanates, reactives, or corrosives, even when managed as UW.

Physical State: Various.

Permissible USEPA Waste Code(s): D001, D004-43, Listed.

Possible ROK Waste Codes: 519900.FL01C719,884LB$0.00FL01C719,884LB$0.00
FL02Flammable Debris contaminated with POLs, fuels, common non-halogenated and halogenated solvents. No free liquids.

Physical State: Solid.

Permissible USEPA Waste Codes: D001, D004-43, Listed.

Possible ROK Waste Codes: 040100, 040200, 090300.FL02C7138,380LB$0.00FL02C7138,380LB$0.00
FL03Flammable Liquids/Solids/Sludges/Debris, Examples include tank sludge, lubricants, adhesives, miscellaneous debris, POL and fuel-saturated absorbents, etc. Use LP03 for loose packs.

Physical State: Various.

Permissible Waste Codes: D001-2, D004-43, Listed.

Possible ROK Waste Codes: 020199, 020299, 060104.FL03C7241,918LB$0.00FL03C7241,918LB$0.00
FL04Flammable Corrosive Liquids/Solids/Sludges/Debris/Aerosols. Use LP03 for loose packs other than aerosols. FL04C7 for use with flammable corrosive aerosols only.

Physical State: Various.

Permissible Waste Codes: D001-2, D004-43, Listed.

Possible ROK Waste Codes: 020199, 020299, 519900.FL04C76,172LB$0.00FL04C76,172LB$0.00
FL05Flammable/Combustible Liquids, e.g., hydrocarbon/organic based POLs, synthetic lubricants, paints, fuels, non-chlorinated solvents, antifreeze, cleaners, adhesives, etc. 2,500-18,000 BTU/Lb. No PCBs or isocyanates.

Physical State: Liquid.

Permissible Waste Codes: D001 (IGN), D004-43, Listed.

Possible ROK Waste Codes: 050100, 050300, 060104, 511399, 060104, 060300.FL05C7364,708LB$0.00FL05C7364,708LB$0.00
FL05B53,500GL$0.00FL05B53,500GL$0.00
FL07Flammable/Combustible Liquids, e.g., hydrocarbon/organic based POLs, synthetic lubricants, paints, fuels, chlorinated solvents, antifreeze, cleaners, adhesives, etc. No PCBs or isocyanates.

Physical State: Liquid.

Permissible Waste Codes: D001 (IGN), D004-43, Listed.

Possible ROK Waste Codes: 040100, 050100, 050300, 060104.FL07C71,288LB$0.00FL07C71,288LB$0.00
FL09Flammable/Combustible Solids and Sludges, e.g., hydrocarbon/ organic based POLs, synthetic lubricants, paints, fuels, non-chlorinated solvents, antifreeze, cleaners, adhesives, etc. 2,500-18,000 BTU/Lb. No PCBs or isocyanates.

Physical State: Various.

Permissible Waste Codes: D001 (IGN), D004-43, Listed.

Possible ROK Waste Codes: 050100, 050300, 060104, 511399.FL09C73,344LB$0.00FL09C73,344LB$0.00
FL10Flammable/Combustible Solids and Sludges, e.g., hydrocarbon/ organic based POLs, synthetic lubricants, paints, fuels, chlorinated solvents, antifreeze, cleaners, adhesives, etc. No PCBs or isocyanates.

Physical State: Various.

Permissible Waste Codes: D001 (IGN), D004-43, Listed.

Possible ROK Waste Codes: 040100, 050100, 050300, 060104.FL10C74,796LB$0.00FL10C74,796LB$0.00
FL13Oxidizers, Non-Reactive, Liquids/Sludges/Solids/Debris, other than chromic acid (see Corrosives).

Physical State: Various.

Permissible USEPA Waste Codes: D001(OX), D002, D004-43, Listed.

Possible ROK Waste Codes:FL13C75,016LB$0.00FL13C75,016LB$0.00
FL16Non-Reactive paints and other coatings listing isocyanates in the ingredients. Use LP16 for loose packs.

Physical State: Various.

Permissible USEPA Waste Codes: D001, D004-43, Listed.

Possible ROK Waste Codes: 050100, 050300.FL16C78,492LB$0.00FL16C78,492LB$0.00
FL17Filters, Used Oil and Fuel, largely drained, mostly combustible paper and plastic.

Physical State: Solid.

Permissible USEPA Waste Code(s): D001, D004-11.

Possible ROK Waste Codes: 060104, 060105, 090300.FL17C7125,136LB$0.00FL17C7125,136LB$0.00
FL18Filters, Used Oil and Fuel, largely drained, mostly non-combustible metal.

Physical State: Solid.

Permissible USEPA Waste Codes: D001, D004-11.

Possible ROK Waste Codes: 060104, 060105, 090300.FL18C782,928LB$0.00FL18C782,928LB$0.00
FL99Military Items, Demil-required, Flammable Solids/Liquids/Debris, e.g., CDE Kits, Vials, Filters, PPE, etc. CD required.

Physical State: Various.

Permissible USEPA Waste Codes: D001, D002, D004-43, Listed.

Possible ROK Waste Codes: 519900.FL99C71,716LB$0.00FL99C71,716LB$0.00
Base
CLINLab Packs/Loose PacksBase
CLINEst. QtyU/MPriceBase AmountBase
CLINEst. QtyU/MPriceOption Period Amount
LP01Lab Packs/Loose Packs, Corrosives, Organic or Inorganic, Liquids or Solids, Non-Flammable.

Physical State: Various.

Permissible USEPA Waste Codes: D002, D004-8, D010-11, Listed.

Possible ROK Waste Codes: Begin with 02.LP01C720,768LB$0.00LP01C720,768LB$0.00
LP02Lab Packs/Loose Packs, Mercury, Elemental Liquid, for mandatory recycling.

Physical State: Various.

Permissible USEPA Waste Codes: D004-11, Listed Inorganics.

Possible ROK Waste Codes: Begin with 11.LP02C7220LB$0.00LP02C7220LB$0.00
LP03Lap Packs/Loose Packs, Flammables and Flammable Corrosives, other than paints and paint-related materials eligible for LP14.

Physical State: Various.

Permissible USEPA Waste Codes: D001-2, D004-8, D010-43, Listed.

Possible ROK Waste Codes: Begin with 02 if corrosive.

LP03C765,566LB$0.00LP03C765,566LB$0.00
LP04Lab Packs/Loose Packs, U.S. Non-Hazardous Waste, for incineration or landfill. Includes pharmaceuticals and non-biohazardous medical wastes. Does not include paints eligible for LP15.

Physical State: Various.

Permissible USEPA Waste Codes: N/A.

Possible ROK Waste Codes: 101300, 514200, 519900.LP04C7154,628LB$0.00LP04C7154,628LB$0.00
LP05Lab Packs/Loose Packs, Non-Reactive Oxidizers.

Physical State: Various.

Permissible USEPA Waste Codes: D001, D002, D004-11, Listed.

Possible ROK Waste Codes: N/A.LP05C72,684LB$0.00LP05C72,684LB$0.00
LP06Lab Packs/Loose Packs, Reactive Oxidizers, including Organic Peroxides. Special Generator packaging may be required.

Physical State: Various.

Permissible USEPA Waste Codes: D001-43, Listed.

Possible ROK Waste Codes: N/A.LP06C728,260LB$0.00LP06C728,260LB$0.00
LP07Lab Packs/Loose Packs, Reactive Metals, Wet/Dry, includes Broken Sodium Lamps, MRE heaters, E-cigarettes and associated components and residues. Special Generator Packaging May Be Required.

Physical State: Various.

Permissible USEPA Waste Codes: D001, D003-43, Listed.

Possible ROK Waste Codes: N/A.

LP07C71,628LB$0.00LP07C71,628LB$0.00
LP08Lab Packs/Loose Packs, Reactives, Non-Metals, Non-Oxidizing. Special Generator packaging may be required.

Physical State: Various.

Permissible USEPA Waste Codes: D001, D003-43, Listed.

Possible ROK Waste Codes: N/A.LP08C7176LB$0.00LP08C7176LB$0.00
LP09Lab Packs/Loose Packs, Toxic Metals.

Physical State: Various.

Permissible USEPA Waste Codes: D004-11, Listed Inorganics.

Possible ROK Waste Codes: N/A.LP09C7920LB$0.00LP09C7920LB$0.00
LP10Lab Packs/Loose Packs, Toxic Organics.

Physical State: Various.

Permissible USEPA Waste Codes: D004-43, Listed inorganics.

Possible ROK Waste Codes:LP10C76,336LB$0.00LP10C76,336LB$0.00
LP11Lab Packs/Loose Packs, Toxic, Acutely Hazardous, P-Listed, for mandatory incineration. Includes pharmaceuticals. May be packaged with U-Listed waste.

Physical State: Various.

Permissible USEPA Waste Codes: D004-43, P-Listed, U-Listed.

Possible ROK Waste Codes: 514200.LP11C7920LB$0.00LP11C7920LB$0.00
LP12Lab Packs/Loose Packs, Toxic, U-Listed, including pharmaceuticals, for mandatory incineration.

Physical State: Various.

Permissible USEPA Waste Codes: D004-43, U-Listed.

Possible ROK Waste Codes: 514200.LP12C7920LB$0.00LP12C7920LB$0.00
LP14Loose-Packed Paints and Paint-Related Materials, Oil/Petroleum-Based, No Isocyanates. May contain up to 10% water-based paints.

Physical State: Various.

Permissible USEPA Waste Codes: D001 (IGN), D004-43, Listed.

Possible ROK Waste Codes: 050100, 050300.LP14C7189,426LB$0.00LP14C7189,426LB$0.00
LP15Loose-Packed Paints and Paint-Related Materials, Water-Based, e.g., Latex.

Physical State: Various.

Permissible USEPA Waste Codes: N/A.

Possible ROK Waste Codes: 050200.LP15C795,442LB$0.00LP15C795,442LB$0.00
LP16Loose-Packed Paints. Non-reactive oil-based paints and other coatings listing isocyanates in the ingredients.

Physical State: Various.

Permissible USEPA Waste Codes: D001, D004-43, Listed.

Possible ROK Waste Codes: 050100, 050300.LP16C719,806LB$0.00LP16C719,806LB$0.00
LP79Lab Packs/Loose Packs, Miscellaneous laboratory-related wastes including preserved specimens, microscope slides, etc. No infectious or biohazardous wastes. May require a Non-Biohazardous or Non-Infectious Certificate.

Physical State: Various.

Permissible Waste Codes: D001-2, D004-43, Listed.

Possible ROK Waste Codes: 090200.LP79C73,300LB$0.00LP79C73,300LB$0.00
Base
CLINNon-Hazardous Waste, per U.S. regulations.
CLINs identified in this section are Non-HW under U.S. Standards, but may be regulated as DW under ROK environmental regulations.Base
CLINEst. QtyU/MPriceBase AmountBase
CLINEst. QtyU/MPriceOption Period Amount
NR01Solids and Debris, for incineration or direct landfill disposal. No asbestos or electrical equipment. No free liquids. <50% combustible solids and debris, e.g., floor sweep/floor dry contaminated with POLs, JOAP oil test tubes, blast media, desiccants, dried paints, coatings, adhesives, etc. For highly combustible materials, see NR11, NR13.

Physical State: Solid.

Permissible USEPA Waste Codes: N/A.

Possible ROK Waste Codes: 519900.NR01C71,437,920LB$0.00NR01C71,437,920LB$0.00
NR02Solids/Debris with Asbestos, for landfill disposal. Special packaging may be required.

Physical State: Solid.

Permissible USEPA Waste Codes: N/A.

Possible ROK Waste Codes: 070101, 070102.NR02C78,096LB$0.00NR02C78,096LB$0.00
NR04Liquids/Sludges, Organic Carbon-Based, primarily consisting of wastes containing hydrocarbons. NR04B5, T2, & T3 for pumpable liquids only.

Physical State: Liquid.

Permissible USEPA Waste Codes: N/A.

Possible ROK Waste Codes: 040200, 090300, 510199.NR04C748,750LB$0.00NR04C748,750LB$0.00
NR04B540,274GL$0.00NR04B540,274GL$0.00
NR05Liquids/Sludges, Inorganic Water-Based, primarily consisting of wastes containing water with suspended or disolved inorganic constituents. NR05B5, T2, & T3 for pumpable liquids only.

Physical State: Various Permissible USEPA Waste Codes: N/A.

Possible ROK Waste Codes: 510299.NR05C7306,596LB$0.00NR05C7306,596LB$0.00
NR05B593,973GL$0.00NR05B593,973GL$0.00
NR08Empty Metal Containers Meeting USEPA "RCRA-Empty" Definition. For Contractor's choice of Recycle or Disposal.

Physical State: Solid.

Permissible Waste Codes: N/A.

Possible ROK Waste Codes: N/A.NR08B1500LB$0.00NR08B1500LB$0.00
NR10Empty Poly/Combustible Containers Meeting USEPA "RCRA-Empty" Definition. For Contractor's choice of Recycle or Disposal. Totes (T1-T3) may have metal components.

Physical State: Solid.

Permissible Waste Codes: N/A.

Possible ROK Waste Codes: N/A.NR10B1500LB$0.00NR10B1500LB$0.00
NR11Combustible Solids/Debris, >90% combustible, other than absorbent-type materials. May contain minor free liquids.

(For absorbent-type materials, see NR13).

Physical State: Various.

Permissible USEPA Waste Codes: N/A.

Possible ROK Waste Codes: 511399.NR11C7396,704LB$0.00NR11C7396,704LB$0.00
NR13Combustible lightweight absorbent-type materials, >90% combustible, e.g., absorbent pads, rags, wipes, contaminated with oil, grease, fuel, antifreeze, paints, high expansion foam (HEF), adhesives, etc. No free liquids.

(For other than absorbent-type solids, see NR11.)

Physical State: Solid.

Permissible USEPA Waste Codes: N/A.

Possible ROK Waste Codes: 511102, 511399.NR13C7295,856LB$0.00NR13C7295,856LB$0.00
NR14Printer Ink and Toner Cartridges.

Physical State: Solid.

Permissible USEPA Waste Code(s): N/A.

Possible ROK Waste Codes: 511803.NR14C78,844LB$0.00NR14C78,844LB$0.00
NR74Fire Extinguishing Media, Non-Toxic, Powder.

Physical State: Solid.

Permissible USEPA Waste Codes: N/A.

Possible ROK Waste Codes: 519900.NR74C73,344LB$0.00NR74C73,344LB$0.00
NR75Grease, Petroleum and Synthetic.

Physical State: Solid/Sludge.

Permissible USEPA Waste Code(s): N/A.

Possible ROK Waste Codes: 511399.NR75C787,956LB$0.00NR75C787,956LB$0.00
NR76Non-PCB transformers, ballasts, capacitors, and other related electrical equipment. No PCBs.

Physical State: Various.

Permissible USEPA Waste Code(s): N/A.

Possible ROK Waste Codes: 511802.NR76C71,716LB$0.00NR76C71,716LB$0.00
NR90AFFF/PFAS-related Solids/Sludges/Debris for incineration, e.g., soil, gravel, filter media, tank bladders, etc. May contain some free liquids. CD required.

Physical State: Various.

Permissible USEPA Waste Codes: N/A.

Possible ROK Waste Codes:NR90C769,564LB$0.00NR90C769,564LB$0.00
NR93AFFF Concentrate liquids for incineration, pumpable, unused or >10% AFFF product by volume. CD required. (See 1.2.10.1).

Physical State: Liquid.

Permissible USEPA Waste Codes: N/A.

Possible ROK Waste Codes:NR93C7200,326LB$0.00NR93C7200,326LB$0.00
NR93B53,110GL$0.00NR93B53,110GL$0.00
NR94AFFF Rinsates and other impacted waters for incineration, pumpable, used or >90% water by volume. Bulk removals may be from storage tanks, containment, storm sewer, ground and surface waters. CD required (See 2.7).

Physical State: Liquid.

Permissible USEPA Waste Codes: N/A.

Possible ROK Waste Codes:NR94C782,484LB$0.00NR94C782,484LB$0.00
NR94B55,754GL$0.00NR94B55,754GL$0.00
NR98Military Articles, Demil-Required, e.g., boots, gloves, CDE kits, filters, masks, MOPP suits, etc. CD required. No uniforms (NR99).

Physical State: Various.

Permissible USEPA Waste Codes: N/A.

Possible ROK Waste Codes:NR98C710,868LB$0.00NR98C710,868LB$0.00
NR99Military Uniforms/Textiles, Demil-Required, for incineration. CD required.

Physical State: Solid.

Permissible USEPA Waste Codes: N/A.

Possible ROK Waste Codes: 512701, 512702, 512703.NR99C7284,873LB$0.00NR99C7284,873LB$0.00
Base
CLINWaste Polychlorinated Biphenyls (PCBs)Base
CLINEst. QtyU/MPriceBase AmountBase
CLINEst. QtyU/MPriceOption Period Amount
PC01Liquid wastes containing at least 2 ppm PCBs and solid wastes containing at least 0.003 ppm PCBs (TCLP) with USEPA Waste Code(s). Examples include but are not limited to fluids, soil, sludge, debris, leaking capacitors. CD required. (See 2.3)

Physical State: Various.

Permissible USEPA Waste Codes: D001-43, Listed.

Possible ROK Waste Codes: 080100, 080300, 080400, 090300...PC01C7400LB$0.00PC01C7400LB$0.00
PC02Mineral oil, water, and other fluids containing less than 2 ppm PCBs.

Physical State: Liquid.

Permissible USEPA Waste Codes: N/A.

Possible ROK Waste Codes:PC02C784LB$0.00PC02C784LB$0.00
PC03Mineral oil, water, and other fluids containing at least 2 ppm PCBs.

Physical State: Liquid.

Permissible USEPA Waste Codes: N/A.

Possible ROK Waste Codes: 080100.PC03C7112LB$0.00PC03C7112LB$0.00
PC05PCB oil-filled capacitors, ballasts, and electrical equipment other than transformers, liquids containing less than 2 ppm PCBs and solids containing less than 0.003 ppm PCBs (TCLP). CD required.

Physical State: Various.

Permissible USEPA Waste Codes: N/A.

Possible ROK Waste Codes: 511802.PC05C7400LB$0.00PC05C7400LB$0.00
PC06PCB oil-filled capacitors, ballasts, and electrical equipment other than transformers, liquids containing at least 2 ppm PCBs and/or solids containing at least 0.003 ppm PCBs (TCLP). CD required.

Physical State: Various.

Permissible USEPA Waste Codes: N/A.

Possible ROK Waste Codes: 080100, 080300, 080400.PC06C7499LB$0.00PC06C7499LB$0.00
PC07PCB oil-filled transformers, liquids containing less than 2 ppm PCBs and solids containing less than 0.003 ppm PCBs (TCLP).

Physical State: Various.

Permissible USEPA Waste Codes: N/A.

Possible ROK Waste Codes: 511802.PC07C71,353LB$0.00PC07C71,353LB$0.00
PC08PCB oil-filled transformers, liquids containing at least 2 ppm PCBs and/or solids containing at least 0.003 ppm PCBs (TCLP). CD required.

Physical State: Various.

Permissible USEPA Waste Codes: N/A.

Possible ROK Waste Codes: 080100, 080300, 080400.PC08C71,078LB$0.00PC08C71,078LB$0.00
PC09PCB-contaminated Solids/Debris with liquids less than 2 ppm PCBs and solids with less than 0.003 ppm PCBs (TCLP). Examples include but are not limited to soil, transformer carcasses, drained equipment, ballasts, rags, PPE, empty containers.

Physical State: Solid.

Permissible USEPA Waste Codes: N/A.

Possible ROK Waste Codes: 511802.PC09C76,219LB$0.00PC09C76,219LB$0.00
PC10PCB contaminated Solids/Debris with liquids at least 2 ppm PCBs and/or solids with at least 0.003 ppm PCBs (TCLP). Examples include but are not limited to soil, transformer carcasses, drained equipment, ballasts, rags, PPE, empty containers. CD required.

Physical State: Solid.

Permissible USEPA Waste Codes: N/A.

Possible ROK Waste Codes: 080400.PC10C71001LB$0.00PC10C71,001LB$0.00
Base
CLINRecycle/RecoveryBase
CLINEst. QtyU/MPriceBase AmountBase
CLINEst. QtyU/MPriceOption Period Amount
RE01Lamps, Fluorescent, Intact. Includes CFLs, U-Bent, Circulars, for recycling or disposal.

Physical State: Solid.

Permissible USEPA Waste Codes: D004-11.

Possible ROK Waste Codes: 514701.RE01C788,841LB$0.00RE01C788,841LB$0.00
RE02Lamps, Fluorescent, Crushed/Broken, for recycling or disposal. May contain filters.

Physical State: Solid.

Permissible USEPA Waste Codes: UW, D004-11.

Possible ROK Waste Codes: 514701.RE02C710,661LB$0.00RE02C110,661LB$0.00
RE03Lamps, Halogen, for recycling or disposal.

Physical State: Solid.

Permissible USEPA Waste Codes: D004-11.

Possible ROK Waste Codes: 519900.RE03C750LB$0.00RE03C750LB$0.00
RE04Lamps, Light Emitting Diode (LED) and High Intensity Discharge (HID), for recycling or disposal.

Physical State: Solid.

Permissible Waste Codes: D004-11.

Possible ROK Waste Codes: 514702.RE04C785LB$0.00RE04C785LB$0.00
RE05Lamps, Mercury/Mercury Vapor, for recycling.

Physical State: Solid.

Permissible Waste Codes: D004-11.

Possible ROK Waste Codes: 110101.RE05C72,633LB$0.00RE05C72,633LB$0.00
RE06Lamps, Metal Halide and Metal Hydride, including Sodium, for recycling or disposal.

Physical State: Solid.

Permissible Waste Codes: D003-11.

Possible ROK Waste Codes: N/A.RE06C748LB$0.00RE06C748LB$0.00
RE08Mercury, Dental Amalgams, associated debris, and residues. Only unused or expired - no medical waste. For recycling or disposal.

Physical State: Various Permissible USEPA Waste Codes: D004-11.

Possible ROK Waste Codes: 101300, 110200.RE08C71,320LB$0.00RE08C11,320LB$0.00
RE09Mercury, Liquid Mercury devices, debris, and residues, for recycling.

Physical State: Various.

Permissible USEPA Waste Codes: D004-11.

Possible ROK Waste Codes: 110101.RE09C71,320LB$0.00RE09C11,320LB$0.00
Base
CLINReactiveBase
CLINEst. QtyU/MPriceBase AmountBase
CLINEst. QtyU/MPriceOption Period Amount
RX01Aerosols, Foaming, Isocyanates or other reactives.

Possible ROK Waste Codes:

Physical State: Various Permissible USEPA Waste Codes: UW, D001-43, Listed.

Possible ROK Waste Codes: 519900.RX01C71,637LB$0.00RX01C71,637LB$0.00
RX06Reactive Oxidizers, e.g., Nitrates, Nitrites, Persulfates, Inorganic Peroxides, No Organic Peroxides.

Physical State: Various.

Permissible USEPA Waste Codes: D001-11, Listed.

Possible ROK Waste Codes: 519900.RX06C710,126LB$0.00RX06C710,126LB$0.00
RX07Polymerizing Materials, e.g, Styrene, Isocyanates, Acrylates, etc.

Physical State: Various.

Permissible USEPA Waste Codes: D001-11, Listed.

Possible ROK Waste Codes: 510399, 519900.RX07C7924LB$0.00RX07C7924LB$0.00
RX08Reactive Metals, e.g., powders, dusts, fines. Air/Water Reactive. Shipped under oil and/or other special packaging may be required.

Physical State: Solid.

Permissible USEPA Waste Codes: D001, D003, D004-11, Listed.

Possible ROK Waste Codes: 519900.RX08C7176LB$0.00RX08C7176LB$0.00
RX09Reactive Metals, Debris. Air/Water Reactive. Shipped under oil and/or other special packaging may be required.

Physical State: Solid.

Permissible USEPA Waste Codes: D001, D003, D004-11, Listed.

Possible ROK Waste Codes: 519900.RX09C7176LB$0.00RX09C7176LB$0.00
RX12Reactive Oxidizer, Super Tropical Bleach, Solid, 28-35% Dry Calcium Hypochlorite (Chlorinated Lime), CAS# 7778-54-3. Approximately 50 pounds per container.

Physical State: Solid.

Permissible USEPA Waste Codes: D001-D011.

Possible ROK Waste Codes: 519900.RX12C71LB$0.00RX12C71LB$0.00
RX13Reactive Oxidizers, including Organic Peroxides. Generator special packaging may be required. Packaged only in up to 5-gallon containers. No Lab Packs or Loose Packs (see LP06).

Physical State: Solid.

Permissible USEPA Waste Codes: D001-D011, Listed.

Possible ROK Waste Codes: 519900.RX13C73,212LB$0.00RX13C73,212LB$0.00
RX98OBA Canisters, EEBDs, and Oxygen Candles, Potentially Reactive, Spent and/or Unspent. Special packaging may be required.

Physical State: Solid.

Permissible USEPA Waste Codes: D001, D003, D004-11.

Possible ROK Waste Codes: 519900.RX98C7207LB$0.00RX98C7207LB$0.00
Base
CLINToxicBase
CLINEst. QtyU/MPriceBase AmountBase
CLINEst. QtyU/MPriceOption Period Amount
TX04Toxic Chromium, Hexavalent (Cr+6), Liquids, Solids, and Sludges.

Physical State: Various.

Permissible Waste Codes: D001 (OX), D004-11, Listed.

Possible ROK Waste Codes: 010299, 519900.TX04C74,228LB$0.00TX04C74,228LB$0.00
TX06Toxic Debris, Inorganic Constituents Only.

Physical State: Debris.

Permissible Waste Codes: D004-11, Listed Inorganics.

Possible ROK Waste Codes: 050200, 519900.TX06C7234,746LB$0.00TX06C7234,746LB$0.00
TX06B625CD$0.00TX06B625CD$0.00
TX07Toxic Debris, Organic Constituents. May also contain inorganic constituents. Total VOCs <500 ppm.

Physical State: Debris.

Permissible USEPA Waste Codes: D004-43, Listed, but no F020-32.

Possible ROK Waste Codes: 040100, 040200, 050100, 050300, 519900.TX07C7150,530LB$0.00TX07C7150,530LB$0.00
TX07B615CD$0.00TX07B615CD$0.00
TX09Toxic Halogenated Liquids/Sludges/Solids/Debris, Non-Flammable. Examples include Solvents, Herbicides, Pesticides. No PCBs or PFAS.

Physical State: Various.

Permissible Waste Codes: UW, D004-43, Listed.

Possible ROK Waste Codes: 010302, 040100, 519900.TX09C74,098LB$0.00TX09C74,098LB$0.00
TX15Toxic Metals-Bearing Liquids. Inorganic constituents only.

Physical State: Liquid.

Permissible USEPA Waste Codes: D004-11, Listed inorganics.

Possible ROK Waste Codes: 519900.TX15C7169,186LB$0.00TX15C7169,186LB$0.00
TX15B52,000GL$0.00TX15B52,000GL$0.00
TX19Toxic Metals-Bearing Solids/Sludges/Some Free Liquids. Inorganic constituents only.

Physical State: Various.

Permissible USEPA Waste Codes: D004-11, Listed inorganics.

Possible ROK Waste Codes: 519900.TX19C770,622LB$0.00TX19C770,622LB$0.00
TX24Toxic Organic Solvents, Technical Grade, pure or mixed solutions. Flashpoint >140°F.

Physical State: Liquid.

Permissible USEPA Waste Codes: D004-43, Listed.

Possible ROK Waste Codes: 040100, 040200.TX24C7660LB$0.00TX24C7660LB$0.00
TX97Toxic Electron Tubes containing metals, intact, Demil-required. CD required.

Physical State: Solid.

Permissible USEPA Waste Codes: D004-11.

Possible ROK Waste Codes: 519900.TX97C7187LB$0.00TX97C7187LB$0.00
TX98Military Items, Demil-required, RCRA Toxic, e.g., CDE Kits, Tents, Filters, PPE, etc. for Conventional RCRA Treatment and Disposal. CD required.

Physical State: Solid.

Permissible USEPA Waste Codes: D004-43, Listed.

Possible ROK Waste Codes: 519900. TX98C7 2,100 LB $0.00 TX98C7 2,100 LB $0.00

File details come from the government source that posted it. Updated .