This document provides an exhibit listing asbestos containing material locations and quantities at various buildings under the Dwight D. Eisenhower Army Medical Center at Fort Gordon, Georgia. It identifies 53 buildings constructed between 1947 and 2019, specifying for each the year constructed, type of asbestos containing or presumed asbestos containing material, whether a DPW report on the material is available, and the total square footage of asbestos or presumed asbestos material. The total quantity of asbestos and presumed asbestos containing material across all buildings is listed as 753,736 square feet, with a note that 5,000 square feet has been abated. The certification statement asserts that the information provided is an accurate listing of asbestos locations and quantities to the best of the author's knowledge.

A related pre-solicitation notice describes intent to award an indefinite-delivery, indefinite-quantity contract with firm-fixed price task orders for healthcare environmental cleaning and related services at Dwight D. Eisenhower Army Medical Center, Fort Gordon, Georgia. The requirement will utilize a competitive 8(a) small business set-aside and be procured under NAICS code 561720 with a size standard of $19.5 million. The solicitation is expected to be issued on August 20, 2021 as a request for proposal posted to SAM.gov. Interested parties should monitor the site for any updates or amendments.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Exhibit K Title: OSHA Asbestos Assessment, Asbestos Containing Material (ACM) & Presumed Asbestos Contianing (PACM) Buildings Status Report ‐DDEA Fort Gordon, GA 30905‐5650

Bldg # Description Year Constructed Type/ACM-PACM* DPW Report Available (Y/N) Quantity ACM-PACM (Total Sq.Ft.)

SOUTHCOM Health Clinic 2010 Floor Tile -VCT N - Negative for ACM 10,241

228 WTU/IDES 1947 Floor Tile - VCT N,PACM 2,482

676 Veterinary Services 1999 Floor Tile - VCT N,PACM 2,000

Rodriguez Army Health Clinic 1959 Floor Tile - VCT Y,PACM 13,691

00296 BSL LABORATORY 2007 Floor Tile - VCT N - Negative for ACM 2,280

00297

HOSPITAL MEDICAL

RECORDS 2007 Floor Tile - VCT N - Negative for ACM 11,312

00298

HYPERBARIC

CHAMBER 1997 Floor Tile - VCT N - Negative for ACM 1,959

00299 HOSPITAL MRI 1995 Floor Tile - VCT N - Negative for ACM 3,078

00300

EISENHOWER ARMY

MEDICAL CENTER 1974 Floor Tile-VCT Y,PACM 549,541

00301

HOSPITAL FAMILY

MEDICINE CLINIC 1995 Floor Tile - VCT N - Negative for ACM 22,111

00302

HOSPITAL

ENGINEERING

SUPPORT

1976 Floor Tile - VCT Y,PACM 5,476

00304

HOSPITAL DECON

FACILITY 2003 Floor Tile - VCT N - Negative for ACM 558

00308

PAD

CORRESPONDENCE/

IMD GRAPHICS

1985 Floor Tile - VCT N - Negative for ACM 2,400

00319

HOSPITAL

RESOURCE

MANAGEMENT / CO

HQ TROOP COMMD

1975 Floor Tile - VCT Y,PACM 13,699

00320

TINGAY DENTAL

CLINIC 1975 Floor Tile - VCT Y,PACM 21,116

00322 AREA DENTAL LAB 1979 Floor Tile - VCT Y,ACM 17,759

00323

HOSPITAL LIMB AND

BRACE SHOP 2005 Floor Tile - VCT 4,000

00324

MEDICAL

WAREHOUSE 2003 Floor Tile - VCT N - Negative for ACM 4,000

00325

HOSPITAL FORMS

AND PUBS 2007 Floor Tile - VCT N - Negative for ACM 4,000

327 BEHAVIOR HEALTH 2008 Floor Tile -VCT N,PACM 3,865

328 HOSPITAL INSPECTOR 2008 Floor Tile - VCT N,PACM 2,482

00329 BEHAVIOR HEALTH 2008 Floor Tile - VCT N - Negative for ACM 6,000

330 HOSPITAL DIRECTORA 2008 Floor Tile - VCT N - Negative for ACM 735

331 CALL CENTER 2008 Floor Tile - VCT N - Negative for ACM 2,940

332 HOSPITAL CONTRACT 2008 Floor Tile - VCT N - Negative for ACM 2,268

00500

VETERINARY

SERVICES 1967 Floor Tile - VCT Y,PACM 2,797

VETERINARY

SERVICES

ADMINISTRATION

1991 Floor Tile - VCT N - Negative for ACM 2,100

21711

HUBER CLINIC

ANNEX 2019 Floor Tile - VCT Y,PACM 3,743

21712 HUBER MED CLINIC 1970 Floor Tile - VCT Y,PACM 6,732

25501

SNYDER DENTAL

CLINIC 1986 Floor Tile - VCT N,PACM 18,889

25712

BLOOD DONOR

CENTER 1969 Floor Tile - VCT Y,PACM 3,396

29605

HEALTH AND

WELLNESS CENTER 1966 Floor Tile - VCT Y,PACM 3,206

29709

CONNELLY HEALTH

CLINIC 1966 Floor Tile - VCT Y,PACM 10,746

33720

MANAGED CARE (IN

DARLING HALL) 1995 Floor Tile - VCT N - Negative for ACM 109,766

47110 PX PHARMACY 1999 Floor Tile - VCT N - Negative for ACM 960

38701

PREVENTIVE

MEDICINE 1954 Floor Tile - VCT Y,PACM 5,985

38703

CLINICAL

INVESTIGATION 1954 Floor Tile - VCT Y,PACM 7,437

38705

CLINICAL

INVESTIGATIONS LAB 1954 Floor Tile - VCT Y,PACM 8,898

38707 91W/M6 SCHOOL 1954 Floor Tile - VCT Y,PACM 2,786

38709

AMTSC (ADVANCED

MEDICAL TEST

SUPPORT CENTER)

1954 Floor Tile - VCT Y,PACM 2,786

38711

TATRIC / EAMC IT /

CLINICAL

INVESTIGATIONS

1954 Floor Tile - VCT Y,PACM 2,786

38713

DENTAL MATERIALS

LAB 1954 Floor Tile - VCT Y,PACM 2,855

38715 91W/M6 CLASSROOMS 1954 Floor Tile - VCT Y,PACM 6,310

38716

HOSPITAL CALL

CENTER 1954 Floor Tile - VCT Y,PACM 1,773

38717 DENTAC HQ 1954 Floor Tile - VCT Y,PACM 6,310

38718

HEARING

CONSERVATION 1950 Floor Tile - VCT Y,PACM 2,358

38719 LPN 91W/M6 SCHOOL 2007 Floor Tile - VCT N - Negative for ACM 3,640

38720

TELEPSYCHOLOGICA

L HEALTH 2008 Floor Tile - VCT N - Negative for ACM 3,321

38801

SE PUBLIC HEALTH

COMMAND HQ /

CLINOPS

1954 Floor Tile - VCT Y,PACM 6,310

38802

SRMC READINESS

HQ 1954 Floor Tile - VCT Y,PACM 4,918

38803

SRMC READINESS

ADMINISTRATION 1954 Floor Tile - VCT Y,PACM 3,973

BDC001

BLOOD DONOR

CENTER 2014 Floor Tile - VCT N - Negative for ACM 9,940

TOTAL ACM-PACM 753,736 Sq. Ft. (less 5,000 Sq.Ft. abated)

NOTES (Floor surfaces and mastic materials both are best defines as "non‐friable" and do not pose a inhalation risk under normal use

a. All buildings constructed after 1980 are considered "negative" for AMC based on construction practice.

b. Based on review of accessible historical ACM database and in the absence of supporting abatements records, buildings without complete supporting records are considered "PACM".

c. Historical ACM records do not contain summary information relative to testing and abatement and homogeneous floor surfaces.

CERTIFICATION STATEMENT

I certify that the information submitted in this exhibit , to the best of my knowledge , is an accurate and complete listing of locations and presence of ACM in these buildings and spaces.

9/2/2020

X Desmond Canty Desmond Canty Asbestos & LBP Program Manager Signed by: CANTY.DESMOND.TERILL.1048345677

Signed by: CANTY.DESMOND.TERILL.1048345677

AMC, 02 SEP 2020

Date Housekeeping Modified Comments

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress

In-Progress e):

File details come from the government source that posted it. Updated .