DRAFT Attachment 3 - Limit of Detection REQUIREMENT 26-374.pdf

PDF 96 KB Posted

Attached to
Microcystin Toxin Analysis Federal contract opportunity
Solicitation number
REQUIREMENTS-26-3745
Issued by
Department of Commerce National Oceanic and Atmospheric Administration

About this file

This document is a technical specification table for microcystin toxin analysis prepared by NOAA's Great Lakes Environmental Research Laboratory (GLERL). The table presents analytical data for the detection and quantification of 20 microcystin and related cyanobacterial toxin analytes using specified methods. Each analyte entry includes the method detection limit measured in parts per trillion (ppt), upper and lower Percent Ion Ratios (PIR), R² values indicating standard curve quality, and the linearity range in ppt.

The detection limits for the analytes range from 0.25 ppt (Aeruginosamide B) to 3.96 ppt (MC-LR), with R² values consistently exceeding 0.997, demonstrating high analytical precision and reliability. Standard curve linearity ranges vary from 0.5-500 ppt to 5-500 ppt depending on the specific analyte. The analytes include various microcystin variants (MC-RR, MC-YR, MC-HtyR, MC-LR, MC-HilR, MC-WR, MC-LA, MC-LY, MC-LW, MC-LF), anabaenopeptins, oscillaginin A, microginin, oscillamide Y, and aeruginosamides. This technical data appears to establish performance standards for toxin analysis capabilities relevant to Great Lakes water quality monitoring and environmental research purposes.

View the file

Other files for this federal contract opportunity

Other files attached to Microcystin Toxin Analysis, newest first.
File Type Posted
DRAFT Attachment 1 - Performance Work Statement REQUIREMENTS-26-3745.pdf PDF
DRAFT Attachment 2 - Technical Specifications REQUIREMENT 26-3745.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DRAFT

NOAA Great Lakes Environmental Research Laboratory (GLERL) Microcystin Toxin Analysis

Limit of Detection

Analyte Method

Detection Limit (ppt)

Upper

PIR*

Lower PIR* R2 value Standard Curve Linearity range (ppt)

D-Asp3Dhb7 MC-RR 1.61 117.32 82.84 0.9989 5-500

MC-RR 0.67 114.09 99.74 0.9990 5-500

Nodularin 1.64 149.18 79.11 0.9970 5-500

MC-YR 1.71 133.74 60.70 0.9976 1-500

MC-HtyR 2.95 141.35 78.30 0.9983 5-500

MC-LR 3.96 146.59 61.98 0.9978 5-500

D-Asp3 MC-LR 2.04 129.21 85.61 0.9972 1-500 MC-HilR 1.24 146.63 97.77 0.9978 5-500

MC-WR 3.91 140.81 57.18 0.9986 5-500

MC-LA 2.23 137.07 89.45 0.9983 1-500

MC-LY 1.90 146.18 64.83 0.9990 1-500

MC-LW 1.45 120.92 58.95 0.9988 1-500

MC-LF 2.18 147.23 53.96 0.9990 1-500

Anabaenopeptin A 3.12 146.60 79.97 0.999 5-500 Anabaenopeptin B 0.36 111.50 96.13 0.999 1-500 Oscillaginin A 1.14 132.69 83.92 0.999 1-500 Microginin 690 methyl ester

2.41 124.01 72.40 1.000 1-500

Oscillamide Y 1.36 147.44 89.47 0.999 1-500 Aeruginosamide B 0.25 133.03 78.82 0.997 0.5-500 Aeruginosamide C 0.33 133.11 62.18 1.000 0.5-500

File details come from the government source that posted it. Updated .