DOR 202610200 Technical Exhibits.pdf

PDF 2 MB Posted

Attached to
AD Project #202610200 Massachusetts Department of Revenue, Abington, Attleboro, Berkley, etc.
Solicitation number
BD-27-1019-DCP06-OOL01-131501
Issued by
Bristol County, Massachusetts

About this file

This technical exhibits document provides detailed design specifications and standards for leased office space for the Massachusetts Department of Revenue (DOR) covering multiple municipalities in southeastern Massachusetts, including Abington, Attleboro, Berkley, Bridgewater, Brockton, and others. The exhibits establish construction and design requirements for approximately 8,500 square feet of usable office area, with flexibility for 7,500 to 10,000 square feet, for a 10-year lease term. The specifications include detailed technical drawings and construction standards for various space types including reception counters with ballistic-resistant glass assemblies, transaction windows with intercom systems, interview rooms, perimeter shelving, staff support areas, wellness rooms, and typical office and huddle room configurations. All specifications emphasize ADA compliance, with detailed notes regarding electrical outlets, data connections, wire management trays, furniture specifications, and finishes. The exhibits reference specific product models such as the Creative Industries Model 1411-S stainless steel deal tray and Retevis RT-9908 intercom systems, with dimensions, clearances, and construction methodologies precisely detailed across multiple technical drawings dated between September 2025 and February 2026.

The technical exhibits establish baseline construction and design standards that contractors must meet or exceed to comply with applicable building codes and ADA guidelines. The architect is designated as responsible for verifying all dimensions and code compliance, while contractors are accountable for meeting all applicable codes including ADA compliance and ensuring proper installation of all components. The document notes that certain items such as the intercom system are to be provided by the user agency or landlord, with specifications for ethernet data jacks to be patched according to standards provided by the user agency. Signage standards are addressed with specific requirements for raised copy and braille, mounted at 60 inches above finish floor with color options of PMS 539C dark blue or silver, and may be procured through Takeform at the specified contact information provided in the exhibits.

View the file

Other files

File Type Posted
DOR 202610200 WARNING.pdf PDF
DOR 202610200 Estoppel Certificate.pdf PDF
DOR 202610200 SNDA.pdf PDF
DOR 202610200 Ten-Year Lease Proposal Form.docx DOCX document
DOR 202610200 SAFS.pdf PDF
DOR 202610200 IFP~1.pdf PDF
DOR 202610200 RNDA.pdf PDF
DOR 202610200 10-year Office Lease.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DUPLEX ELECTRICAL OUTLET

18" AFF UNLESS NOTED

DATA OUTLETS. 2 PER OUTLETS PER

LOCATION. 18" AFF UNLESS NOTED

SYMBOL KEY

QUAD ELECTRICAL OUTLET

18" AFF UNLESS NOTED. OUTLET TO BE ALWAYS ON

2.5" GROMMETS

WM

WIRE MANAGEMENT TRAY

5' -0

10" X 12" STAINLESS STEEL DEAL TRAY PROVIDED BY

CONTRACTOR

2' -2

(3) 2.5" GROMMETS ON BOTH COUNTERS AND

THROUGH WALL FOR ELECTRIC AND DATA CORDS FOR

INTERCOM. 12" FROM TRAY . FEED INTO CABLE TRAY.

SPEAKER TO BE INSTALLED AS PER SPECS

COUNTER NOT TO PROJECT MORE THAN 4" FROM THE

WALL. AGENCY TO VALIDATE IF 12" REQUIRED AS A

WRITING SURFACE

1' -8

B

5'-0" CLEARANCE REQUIRED IN FRONT OF RECEPTION

COUNTER FOR PRIVACY

7'-0"A

WM

WM

INTERCOM

SPEAKER

2' -1

0"

WELDED

STEEL FRAME

STAINLESS STEEL DEAL TRAY

PROVIDED BY CONTRACTOR

(12"X10")

SUPPORT AS NEEDED

BALLISTIC GLASS SEE NOTES

1/2" GWB OVER

BALLISTIC FIBERGLASS

ON METAL STUDDING

BALLISTIC GLASS WINDOW

INTERCOM SYSTEM 48" AFF

M

AX

T O

P O

F C

O U

N

TE

R

4' -2

M

IN

IM

U M

G

LA

SS

H

EI

G

H T

7'-0" MINIMUM WIDTH OF GLASS

CEILING HEIGHT

VARIES

2 MINIMUM RECESSED CAN

LIGHTS OVER WORKSURFACE

GROMMET AND

INTERCOM SPEAKER

1/2" GWB OVER

BALLISTIC FIBERGLASS

ON METAL STUDDING

1/2" GWB OVER BALLISTIC

FIBERGLASS ON METAL

STUDDING BOTH SIDES OF

WALL

2' -1

0"

BALLISTIC GLASS SEE

NOTES

DEAL TRAY SEE NOTES

STAFF SIDERECEPTION AREA

1/2" GWB OVER BALLISTIC

FIBERGLASS ON METAL

STUDDING BOTH SIDES OF

WALL

1'-0"

WALL TO UNDERSIDE OF

DECK1'-0"

CEILING HEIGHT PER

PROJECT SPECIFICATIONS

COUNTER SUPPORTS AS

NEEDED

PLASTIC LAMINATE

COUNTERS ON 34" PLYWOOD

SUBSTRATE. LAMINATE ON

ALL EXPOSED SURFACES.

GROMMETS TO BE PROVIDED

WIRE MANAGEMENT TRAY

2 14" EDGE BAND TO

ACOMODATE DEAL TRAY.

2 RECESSED CAN LIGHTS

MIN. OVER WORKSURFACE

WELDED STEEL FRAME, TO

MEET LEVEL 1 BALLISTICS

COUNTER SUPPORTS AS

NEEDED

NOTES FOR EXHIBIT 2.2

· GLASS IN WINDOW TO BE UL 752 LEVEL 1 BALLISTIC RESISTANT LAMINATED GLASS

ASSEMBLY, CONSTRUCTED PER ASTM C1172, AND COMPLIANT WITH ANSI Z97.1

CLASS A AND CPSC 16 CFR 1201 CATEGORY II, AS APPLICABLE. SAFETY GLASS

SHALL CONFORM TO ASTM C1036.

· DEAL TRAY STAINLESS STEEL 12 X 10 DROP IN MODEL TO ALLOW TRANSFER OF

SMALL ITEMS. CREATIVE INDUSTRIES MODEL1411-S OR SIMILAR

· INTERCOM SYSTEM TO BE PROVIDED BY USER AGENCY. SIMILAR TO RETEVIS

RT-9908 WINDOW SPEAKER,WINDOW INTERCOM DUAL-WAY VOICE,WINDOW

SPEAKER INTERCOM SYSTEM. OUTLET, AND 3 GROMMETS TO BE PROVIDED AS

NOTED.

· BOTH SIDES OF WALL BETWEEN AGENCY AND PUBLIC TO BE 1/2" GWB OVER

BALLISTIC FIBERGLASS ON METAL STUDS

· COUNTER DEPTH MINIMUM 12" EACH SIDE. SUPPORTS TO HAVE HOLE TO LOCK

LAPTOP AND CHANNEL FOR WIRE MANAGEMENT

· COUNTER FINISH TO BE SELECTED BY PROJECT ARCHITECT WITH APPROVAL FROM

AGENCY.

· WALL WITH TRANSACTION COUNTER AND GLASS TO DECK

· 4" STRAIGHT VINYL WALL BASE THROUGH OUT

· IF DOOR HAS DOOR CLOSER ROOM IS REQUIRED TO BE 6" LONGER, FOR EACH

DOOR. IF BOTH DOORS HAVE CLOSER ROOM WOULD NEED TO BE MINIMUM OF

12'-0" X 8'-0"

· NOTE DRAWING FOR REFERENCE DETAILS ON GLASS FRAME AND CONFIGURATION

TO BE DETERMINED BY CONTRACTOR.

· DATA JACK FOR ETHERNET CABLE TO BE PATCHED ACCORDING TO

SPECIFICATIONS PROVIDED BY USER AGENCY.

· WIRE MANAGEMENT TRAY TO BE INCLUDED AS SHOWN

NOTE DRAWING IS FOR REFERENCE ONLY ARCHITECT IS RESPONSIBLE TO VERIFY DIMENSIONS AND

CODE COMPLIANCE. ALL GOVERNMENT PROPERTIES ARE TO COMPLY WITH ADA GUIDELINES.

ARCHITECT IS RESPONSIBLE TO CONFIRM THAT ADA ROOM MEETS COMPLIANCE

SCALE AS NOTED

DATE 01/14/2026

CREATED BY: BRK

CHECKED BY: JM/KH

RECEPTION COUNTER WITH BALLISTIC GLASS

TECHNICAL EXHIBIT #2.2

NOTE EXHIBITS ARE FOR REFERENCE ONLY. CONTRACTOR IS

RESPONSIBLE TO MEET APPLICABLE CODESELEVATION A SCALE 1/2" = 1'-0"SECTION BSCALE 1/2" = 1'-0"

PLAN SCALE 3/8" = 1'-0"

T:\Projects\_LEASING EXHIBIT UPDATES\2.0 Design-Drawings\Working\LEASING EXHIBITS_UPDATE 2026.dwg, 1/14/2026 10:32:43 AM

T

Y P

14"

NOTES:

1. VERIFY LOCATION & DEPTH OF ALL SHELVING

WITH AGENCY PRIOR TO INSTALLATION.

2. WHEN CASE FILE SHELVING IS BACK TO BACK

PROVIDE CONST 5/8" PLYWOOD DIVIDERS ENTIRE

LENGTH OF BACK TO BACK SHELVING.

CEILING HEIGHT VARIES

PARTITION

CONSTRUCTION

VARIES

CONST 2x1 WOOD

BLOCKING AT

EACH SHELF TYP

32" O.C. MAX

TECHNICAL EXHIBIT 3

PERIMETER SHELVING

SCALE: NTS

SECTION

SCALE: NTS

ELEVATION

CONST. SHELF CLEAT

3/4" PLYWOOD

SUPPORTS @ 3'-0"

MAX O.C. W/

EDGE BLOCKING

3/4"x 12" CONST.

PLYWOOD SHELVING

(7 TOTAL)

CONST. 1"X3"

SHELF CLEAT

1"x4" CONST WD BASE

W/ 2"x4" BLKG

CONDITION @ 24" & 18"

SHELVING SHOWN DOTTED

4" VINYL STRAIGHT WALL

BASE FOR CARPET

4" VINYL COVE BASE WALL

FOR VINYL COMPOSITE TILE

O

C

CEILING HEIGHT

VARIES

1"x4" CHAIR RAILCONST WD

BLOCKING

STUDDING

TECHNICAL EXHIBIT 4

TYPICAL CHAIR RAIL DETAIL

NOT TO SCALE

FOR REFERENCE ONLY

VERIFY ALL DIMENSIONS

8'-0"

'-6

1'

-7

2.5" GROMMET ON

STAFF SIDE FOR

ELECTRIC AND

DATA CORDS. 12"

FROM TRAY .

2.5" GROMMET ON PUBLIC

SIDE FOR COMPUTER LOCK,

ELECTRIC AND DATA CORDS.

12" FROM TRAY . FEED INTO

CABLE TRAY. OPTIONAL

MONITOR ARM WITH

KEYBOARD.

1' -0

STAFF SIDE

5' -3

A

LAPTOP

AND DOCK NIC

1'-0"

3'-0"

PUBLIC SIDE

LAPTOP

AND DOCK NIC

QUAD ELECTRICAL OUTLET

18" AFF UNLESS NOTED

DATA OUTLETS. 2 PER OUTLETS PER LOCATION,

M

IN

IM

U

M

WM

WM

WIRE MANAGEMENT TRAY

LAPTOP

AND DOCK

NIC

3' -6

BALLISTIC GLASS SEE

NOTES

DEAL TRAY SEE

NOTES

PUBLIC

SIDE

STAFF

SIDE

COUNTER

SUPPORTS SEE

NOTES

1/2" GWB OVER BALLISTIC

FIBERGLASS ON METAL STUDDING

BOTH SIDES OF WALL

1/2" GWB OVER BALLISTIC

FIBERGLASS ON METAL STUDDING

BOTH SIDES OF WALL

3' -6

3'

-6

CEILING HEIGHT VARIES

WELDED STEEL

FRAME

STAINLESS STEEL DEAL TRAY

PROVIDED BY CONTRACTOR

(12"X10")

SUPPORTS AS

NEEDED

REQUIRED TO

LOCK LAPTOP

BALLISTIC GLASS SEE NOTES

1/2" GWB OVER

BALLISTIC FIBERGLASS

ON METAL STUDDING

2.5" GROMMET IN WALL

WIRE MANAGEMENT TRAY

MOUNTED UNDER COUNTER

1/2" GWB OVER BALLISTIC FIBERGLASS

ON METAL STUDDING

3'-0"

NOTES

· GLASS IN WINDOW TO BE UL 752 LEVEL 1 BALLISTIC RESISTANT LAMINATED GLASS

ASSEMBLY, CONSTRUCTED PER ASTM C1172, AND COMPLIANT WITH ANSI Z97.1

CLASS A AND CPSC 16 CFR 1201 CATEGORY II, AS APPLICABLE. SAFETY GLASS

SHALL CONFORM TO ASTM C1036.

· DEAL TRAY STAINLESS STEEL 12 X 10 DROP IN MODEL TO ALLOW TRANSFER OF

SMALL ITEMS. CREATIVE INDUSTRIES MODEL1411-S OR SIMILAR

· INTERCOM SYSTEM TO BE PROVIDED BY USER AGENCY. SIMILAR TO RETEVIS

RT-9908 WINDOW SPEAKER,WINDOW INTERCOM DUAL-WAY VOICE,WINDOW

SPEAKER INTERCOM SYSTEM. OUTLET, AND 3 GROMMETS TO BE PROVIDED AS

NOTED.

· BOTH SIDES OF WALL BETWEEN AGENCY AND PUBLIC TO BE 1/2" GWB OVER

BALLISTIC FIBERGLASS ON METAL STUDS

· COUNTER DEPTH MINIMUM 12" EACH SIDE. SUPPORTS TO HAVE HOLE TO LOCK

LAPTOP AND CHANNEL FOR WIRE MANAGEMENT

· COUNTER FINISH TO BE SELECTED BY PROJECT ARCHITECT WITH APPROVAL FROM

AGENCY.

· WALL WITH TRANSACTION COUNTER AND GLASS TO DECK

· 4" STRAIGHT VINYL WALL BASE THROUGH OUT

· IF DOOR HAS DOOR CLOSER ROOM IS REQUIRED TO BE 6" LONGER, FOR EACH

DOOR. IF BOTH DOORS HAVE CLOSER ROOM WOULD NEED TO BE MINIMUM OF

12'-0" X 8'-0"

· NOTE DRAWING FOR REFERENCE DETAILS ON GLASS FRAME AND CONFIGURATION

TO BE DETERMINED BY CONTRACTOR.

· DATA JACK FOR ETHERNET CABLE TO BE PATCHED ACCORDING TO

SPECIFICATIONS PROVIDED BY USER AGENCY.

· WIRE MANAGEMENT TRAY TO BE INCLUDED AS SHOWN

NOTE DRAWING IS FOR REFERENCE ONLY ARCHITECT IS RESPONSIBLE TO VERIFY DIMENSIONS AND

CODE COMPLIANCE. ALL GOVERNMENT PROPERTIES ARE TO COMPLY WITH ADA GUIDELINES.

ARHCITECT IS RESPONSIBLE TO CONFIRM THAT ADA ROOM MEETS COMPLIANCE

SCALE AS NOTED

DATE 01/12/ 2026

CREATED BY: BRK

CHECKED BY: MJ/JM

TYPICAL TRANSACTION COUNTER FOR

INTERVIEW ROOM

TECHINICAL EXHIBIT #6

SECTION SCALE 1/2" = 1'-0"ELEVATION STAFF SIDE

PLAN SCALE 1/4" = 1'-0"

SCALE 1/2" = 1'-0"

NOTES

T:\Projects\_LEASING EXHIBIT UPDATES\2.0 Design-Drawings\Working\DOR EXHIBITS_UPDATES.dwg, 1/12/2026 11:32:37 AM

8'-0"

'-6

1'

-7

2.5" GROMMET ON

STAFF SIDE FOR

ELECTRIC AND

DATA CORDS. 12"

FROM TRAY .

2.5" GROMMET ON PUBLIC

SIDE FOR COMPUTER LOCK,

ELECTRIC AND DATA CORDS.

12" FROM TRAY . FEED INTO

CABLE TRAY. OPTIONAL

MONITOR ARM WITH

KEYBOARD.

1' -6

STAFF SIDE

A LAPTOP

AND DOCK NIC

3'-0"

PUBLIC SIDE

QUAD ELECTRICAL OUTLET

18" AFF UNLESS NOTED

DATA OUTLETS. 2 PER OUTLETS PER LOCATION,

M

IN

IM

U

M

WM

WM

WIRE MANAGEMENT TRAY

LAPTOP

AND DOCK

NIC

4' -0

3' -6

BALLISTIC GLASS SEE

NOTES

DEAL TRAY SEE

NOTES

PUBLIC

SIDE

STAFF

SIDE

COUNTER

SUPPORTS SEE

NOTES

1/2" GWB OVER BALLISTIC

FIBERGLASS ON METAL STUDDING

BOTH SIDES OF WALL

1/2" GWB OVER BALLISTIC

FIBERGLASS ON METAL STUDDING

BOTH SIDES OF WALL

GROMMET

THROUGH WALL

3' -6

3'

-6

CEILING HEIGHT VARIES

WELDED STEEL

FRAME

STAINLESS STEEL DEAL TRAY

PROVIDED BY CONTRACTOR

(12"X10")

SUPPORTS AS

NEEDED

REQUIRED TO

LOCK LAPTOP

BALLISTIC GLASS SEE NOTES

1/2" GWB OVER

BALLISTIC FIBERGLASS

ON METAL STUDDING

2.5" GROMMET IN WALL

WIRE MANAGEMENT TRAY

MOUNTED UNDER COUNTER

1/2" GWB OVER BALLISTIC FIBERGLASS

ON METAL STUDDING

3'-0"

NOTES

· GLASS IN WINDOW TO BE UL 752 LEVEL 1 BALLISTIC RESISTANT LAMINATED GLASS

ASSEMBLY, CONSTRUCTED PER ASTM C1172, AND COMPLIANT WITH ANSI Z97.1

CLASS A AND CPSC 16 CFR 1201 CATEGORY II, AS APPLICABLE. SAFETY GLASS

SHALL CONFORM TO ASTM C1036.

· DEAL TRAY STAINLESS STEEL 12 X 10 DROP IN MODEL TO ALLOW TRANSFER OF

SMALL ITEMS. CREATIVE INDUSTRIES MODEL1411-S OR SIMILAR

· INTERCOM SYSTEM TO BE PROVIDED BY LANDLORD, AGENCY TO CONFIRM

SPECIFICATIONS SIMILAR TO RETEVIS RT-9908 WINDOW SPEAKER,WINDOW

INTERCOM DUAL-WAY VOICE,WINDOW SPEAKER INTERCOM SYSTEM. OUTLET, AND

3 GROMMETS TO BE PROVIDED AS NOTED.

· BOTH SIDES OF WALL BETWEEN AGENCY AND PUBLIC TO BE 1/2" GWB OVER

BALLISTIC FIBERGLASS ON METAL STUDS

· COUNTER DEPTH MINIMUM 12" EACH SIDE. SUPPORTS TO HAVE HOLE TO LOCK

LAPTOP AND CHANNEL FOR WIRE MANAGEMENT

· COUNTER FINISH TO BE SELECTED BY PROJECT ARCHITECT WITH APPROVAL FROM

AGENCY.

· WALL WITH TRANSACTION COUNTER AND GLASS TO DECK

· 4" STRAIGHT VINYL WALL BASE THROUGH OUT

· IF DOOR HAS DOOR CLOSER ROOM IS REQUIRED TO BE 6" LONGER, FOR EACH

DOOR. IF BOTH DOORS HAVE CLOSER ROOM WOULD NEED TO BE MINIMUM OF

12'-0" X 8'-0"

· NOTE DRAWING FOR REFERENCE DETAILS ON GLASS FRAME AND CONFIGURATION

TO BE DETERMINED BY CONTRACTOR.

· DATA JACK FOR ETHERNET CABLE TO BE PATCHED ACCORDING TO

SPECIFICATIONS PROVIDED BY USER AGENCY.

· WIRE MANAGEMENT TRAY TO BE INCLUDED AS SHOWN

NOTE DRAWING IS FOR REFERENCE ONLY ARCHITECT IS RESPONSIBLE TO VERIFY

DIMENSIONS AND CODE COMPLIANCE. ALL GOVERNMENT PROPERTIES ARE TO

COMPLY WITH ADA GUIDELINES. ARCHITECT IS RESPONSIBLE TO CONFIRM THAT

ADA ROOM MEETS COMPLIANCE. NOTE DOOR CLOSER REQUIRED IF 54"

CLEARANCE IS REQUIRED.

SCALE AS NOTED

DATE 02/12/ 2026

CREATED BY: BRK

CHECKED BY: MJ/JM

TYPICAL TRANSACTION COUNTER FOR

INTERVIEW ROOM

TECHINICAL EXHIBIT #6A

SECTION SCALE 1/2" = 1'-0"ELEVATION STAFF SIDE

PLAN SCALE 1/4" = 1'-0"

SCALE 1/2" = 1'-0"

T:\Projects\_LEASING EXHIBIT UPDATES\2.0 Design-Drawings\Working\DOR EXHIBITS_UPDATES.dwg, 2/19/2026 9:57:50 AM

A

STAFF SIDE

LAPTOP

AND DOCK

NIC

1' -7

1'-0"

3'-0"

NOTE 5' TURNING

RADIUS MINIMUM ON

EACH SIDE OF ROOM

BALLISTIC

GLASS SEE

NOTES

1' -0

8'-0"

'-0

PUBLIC SIDE

4' -0

M

IN

IM

U

M

WM

QUAD ELECTRICAL OUTLET

18" AFF UNLESS NOTED

DATA OUTLETS. 2 PER OUTLETS PER LOCATION,

WM

WIRE MANAGEMENT TRAY

2.5" GROMMET ON PUBLIC

AND STAFF SIDE FOR

COMPUTER LOCK, ELECTRIC

AND DATA CORDS. 12" FROM

TRAY . FEED INTO CABLE

TRAY. OPTIONAL MONITOR

ARM WITH KEYBOARD.

1/2" GWB OVER BALLISTIC

FIBERGLASS ON METAL STUDDING

BOTH SIDES OF WALL

2' -6

BALLISTIC GLASS SEE

NOTES

DEAL TRAY SEE

NOTES

COUNTER

SUPPORTS SEE

NOTES

STAFF SIDE

1/2" GWB OVER BALLISTIC

FIBERGLASS ON METAL STUDDING

BOTH SIDES OF WALL

2' -6

4'

-6

CEILING HEIGHT VARIES

WELDED STEEL

FRAME

STAINLESS STEEL DEAL TRAY

PROVIDED BY CONTRACTOR

(12"X10")

SUPPORT AS NEEDED

BALLISTIC GLASS SEE NOTES

1/2" GWB OVER

BALLISTIC FIBERGLASS

ON METAL STUDDING

M

AX

T O

P O

F C

O U

N

TE

R

2.5" GROMMET IN WALL

WIRE MANAGEMENT TRAY MOUNTED

UNDER COUNTER. GROMMET TO CLEAR

CABLE MANAGEMENT TRAY

1' -8

NOTES

· GLASS IN WINDOW TO BE UL 752 LEVEL 1 BALLISTIC RESISTANT LAMINATED GLASS

ASSEMBLY, CONSTRUCTED PER ASTM C1172, AND COMPLIANT WITH ANSI Z97.1

CLASS A AND CPSC 16 CFR 1201 CATEGORY II, AS APPLICABLE. SAFETY GLASS

SHALL CONFORM TO ASTM C1036.

· DEAL TRAY STAINLESS STEEL 12 X 10 DROP IN MODEL TO ALLOW TRANSFER OF

SMALL ITEMS. CREATIVE INDUSTRIES MODEL1411-S OR SIMILAR

· INTERCOM SYSTEM TO BE PROVIDED BY USER AGENCY. SIMILAR TO RETEVIS

RT-9908 WINDOW SPEAKER,WINDOW INTERCOM DUAL-WAY VOICE,WINDOW

SPEAKER INTERCOM SYSTEM. OUTLET, AND 3 GROMMETS TO BE PROVIDED AS

NOTED.

· BOTH SIDES OF WALL BETWEEN AGENCY AND PUBLIC TO BE 1/2" GWB OVER

BALLISTIC FIBERGLASS ON METAL STUDS

· COUNTER DEPTH MINIMUM 12" EACH SIDE. SUPPORTS TO HAVE HOLE TO LOCK

LAPTOP AND CHANNEL FOR WIRE MANAGEMENT

· COUNTER FINISH TO BE SELECTED BY PROJECT ARCHITECT WITH APPROVAL FROM

AGENCY.

· WALL WITH TRANSACTION COUNTER AND GLASS TO DECK

· 4" STRAIGHT VINYL WALL BASE THROUGH OUT

· IF DOOR HAS DOOR CLOSER ROOM IS REQUIRED TO BE 6" LONGER, FOR EACH

DOOR. IF BOTH DOORS HAVE CLOSER ROOM WOULD NEED TO BE MINIMUM OF

12'-0" X 8'-0"

· NOTE DRAWING FOR REFERENCE DETAILS ON GLASS FRAME AND CONFIGURATION

TO BE DETERMINED BY CONTRACTOR.

· DATA JACK FOR ETHERNET CABLE TO BE PATCHED ACCORDING TO

SPECIFICATIONS PROVIDED BY USER AGENCY.

· WIRE MANAGEMENT TRAY TO BE INCLUDED AS SHOWN

NOTE DRAWING IS FOR REFERENCE ONLY ARCHITECT IS RESPONSIBLE TO VERIFY DIMENSIONS AND

CODE COMPLIANCE. ALL GOVERNMENT PROPERTIES ARE TO COMPLY WITH ADA GUIDELINES.

ARHCITECT IS RESPONSIBLE TO CONFIRM THAT ADA ROOM MEETS COMPLIANCE

SCALE AS NOTED

DATE 01/12/2026

CREATED BY: BRK

CHECKED BY: CB, MJ/JM

ADA COMPLIANT TRANSACTION COUNTER

FOR INTERVIEW ROOM

TECHINICAL EXHIBIT #6B

SECTION SCALE 1/2" = 1'-0"ELEVATION STAFF SIDE

PLAN SCALE 1/4" = 1'-0"

SCALE 1/2" = 1'-0"

T:\Projects\_LEASING EXHIBIT UPDATES\2.0 Design-Drawings\Working\DOR EXHIBITS_UPDATES.dwg, 1/12/2026 1:50:40 PM

INTERCOM PURCHASED BY USER AGENCY. LAST UNIT

PURCHASED FROM AMAZON.COM : RETEVIS RT-9908

WINDOW SPEAKER,WINDOW INTERCOM DUAL-WAY

VOICE,WINDOW SPEAKER INTERCOM SYSTEM FOR

BUSINESS,BANK,TICKET WINDOW : ELECTRONICS

SCALE NTS

DATE 09/04/ 2025

CREATED BY: BRK

CHECKED BY:

DUAL WAY WINDOW INTERCOM SYSTEM

NOTE EXHIBITS ARE FOR REFERENCE ONLY. CONTRACTOR IS RESPONSIBLE TO MEET APPLICABLE CODES INCLUDING ADA COMPLIANCE

TECHNICAL EXHIBIT # 9

T:\Administrative\Boiler Plate\Leasing\2.0 Design-Drawings\CAD\LEASING SPACE STANDARDS.dwg, 9/5/2025 3:02:57 PM

42 AFF

MINUMUM

TABLE

1'-6"

CLEAR

RESILIENT

FLOORING

CARPET

2'

-1 0"

8'-0"

REFRIGERATOR

NIC

34" MINIMUM WIDTH AND

24" MINIMUM HEIGHT

CLEARANCE. 17" KNEE

SPACE MINIMUM.

3' -6

S

EC

TI

O

N A

1' -6

2' -3

2' -1

0"

1'-5"

9"

REMOVABLE

PANEL

ROOMS WITH PLUMBING: KITCHEN / WELLNESS

DUPLEX ELECTRICAL

OUTLET

18" AFF UNLESS NOTED

DATA OUTLETS. 2 PER

OUTLETS PER

LOCATION

WELLNESS ROOM NOTES

· FURNITURE SHOWN TO BE PROVIDED BY TENANT

· LIGHTS TO BE DIMMABLE

· FLOORING AT SINK TO BE RESILIENT FLOORING

· IF SIDE LIGHT PROVIDED ENTIRE WINDOW TO BE

PRIVACY FILM

· MIRROR & BULLETIN BOARD NOT PROVIDED BY

CONTRACTOR

WELLNESS ROOM

TECHNICAL EXHIBIT #13

PLAN TYPICAL 80 SQ FT

SCALE 1/2" =1'-0"

SCALE 1/4" = 1'-0"

SCALE as noted

DATE 10/07/2025

CREATED BY: BK

CHECKED BY : CB and EA

SINK SECTION SCALE 1/2" = 1'-0"

ELEVATION OF MILLWORK WELLNESS ROOM

EXHIBITS ARE FOR REFERENCE ONLY. CONTRACTOR IS RESPONSIBLE TO MEET APPLICABLE CODES

T:\Administrative\Boiler Plate\Leasing\2.0 Design-Drawings\CAD\LEASING SPACE STANDARDS.dwg, 10/7/2025 3:17:15 PM

AutoCAD SHX Text

REF

2' -1

0"3' -6

1' -6

2'-0" 1'-6"3'-0"

1' -3

2'

-6

3'-0"

24" MINIMUM HEIGHT

CLEARANCE. 17" KNEE

SPACE MINIMUM.

S

EC

TI

O

N A

1'-6"

DUPLEX ELECTRICAL OUTLET

18" AFF UNLESS NOTED

DATA OUTLETS. 2 PER OUTLETS PER LOCATION

H20

MARKER BOARD AND/OR

TACK BOARD TBD

8' -0

"C H

C H

C

H 07C

H

42"

AFF

42"

AFF

QUENCH WATER COOLER

AND WALL PHONE TBD

A

MARKER BOARD AND

TACK BOARD ALIGN

BOTTOM

WITH COUNTER

30 x 60

30 x 60

30 x 60

A

42"

AFF

42"

AFF

H20

WALL PHONE TBD

QUENCH WATER COOLER

2' -3

2' -1

0"

1'-5"

9"

REMOVABLE

PANEL

SCALE AS NOTED

DATE 06/06/2025

CREATED BY: BRK

CHECKED BY: CB

STAFF SUPPORT

TECHNICAL EXHIBIT #14

ELEVATION A OF MILLWORK STAFF SUPPORT ROOM

PLAN KEY

SCALE 1/2" =1'-0"

SCALE 1/4" =1'-0"TYPICAL PLAN 200 SQ FT STAFF SUPPORT SPACE

SCALE 1/4" =1'-0"TYPICAL PLAN 400 SQ FT STAFF SUPPORT SPACE

NOTES

PLANS SHOW PREFERRED OPTION FOR QUENCH WATER COOLERS BY MOST AGENCIES . VALIDATE

LOCATION WITH AGENCY. SOME AGENCIES PREFER COUNTER TOP OPTIONS WHEN SPACE PERMITS

NOTE EXHIBITS ARE FOR REFERENCE ONLY. CONTRACTOR IS RESPONSIBLE TO MEET APPLICABLE CODES INCLUDING ADA COMPLIANCE

SINK SECTION A SCALE 1/2" = 1'-0"

T:\Administrative\Boiler Plate\Leasing\2.0 Design-Drawings\CAD\LEASING SPACE STANDARDS.dwg, 6/3/2025 5:06:37 PM

AutoCAD SHX Text

REFRIGERATOR NIC

WALL WITH SIDELIGHT WALL AND SIDELIGHTWALL WITH NO SIDELIGHT

AF

F

SIGNAGE - INSTALLATION FOR PERMANENT IDENTIFICATION OF WALLED SPACES (WALL/GLASS) Mounting height shall be 60" above the finish floor (AFF) measured to the baseline of the raised text.

NOTE: the above recommended placement is intended to meet the sign location requirements of the 2010 ADA standards. sec.703.4.1

Sign alignment to be mounted on surface adjacent to the latch side of the door, within 2" - 4" from the door trim.

NOTE: The above recommended placement is intended to meet the sign location requirements of the 2010 ADA standards. sec.703.4.2

Conference

Conference

Conference

PLACE SIGN ON SIDELIGHT PLACE SIGN ON WALL PLACE SIGN ON WALL

2" - 4" FROM

FRAME

2" - 4" FROM

FRAME

2" - 4" FROM

FRAME

INTERIOR SIGNAGE STANDARD

NOTE BACKERS REQUIRED WHEN MOUNTED ON GLASS. BACKER COLOR TO BE CONFIRMED BY AGENCY.

CONTRACTOR RESPONSIBLE TO MEET ADA COMPLIANCE ON ALL SIGNS. INCLUDING INSTALLATION.

ROOM NUMBERS MUST BE RENDERED IN RAISED COPY WITH BRAILLE PER CODE AND DRAWINGS ABOVE. INSERT TEXT TO BE APTOS FONT PRINTED ON POLYESTER MEDIA PER DRAWINGS AND CALLOUTS. ALL SIGNS TO BE POSTED BY CONTRACTOR. ADDITIONAL MATERIAL AND PRINTING INSTRUCTIONS TO BE SUPPLIED TO AGENCY FOR FUTURE SIGNS.

SIGNS CAN BE PURCHASED THROUGH TAKEFORM STYLE VIVID (TAKEFORM.NET). ORDERS AND QUESTIONS CAN BE PLACED BY EMAILING MIKE R. HUNGERFORD 1.800.528.1398 MRH@TAKEFORM.NET. FINAL SIGNAGE OPTIONS AND

SIGNS TO BE SUBMITTED TO DCAMM PROJECT MANGER FOR APPROVAL.

TAKEFORM ROOM SIGNS ARE TYPE J.3B VVAW-01001105-R9DO1. TAKEFORM COLROS DARK BLUE PMS 539C OR SILVER

CMYK 8,9,5,35

TAKEFORM WORKSATION SIGNS ARE TYPE L.b VV1AW-01000701-R9D01

THIS IS FOR INTERNAL AGENCY SPACE ONLY. THESE SIGNS ARE NOT APPLICABLE FOR BATHROOM OR BUILDING CORE

SIGNS

Conference

TYPICAL WORKSTATION SIGNS

5"W X 3.5"H WITH INSERT

MOUNTED WITH MAGNET, PIN OR CUBICLE HANGER

DEPENDING ON WORKSTATIONS SPECIFIED

TYPICAL OFFICE SIGNS

CONFERENCE, OFFICES, FOCUS ROOMS, PHONE ROOMS, HUDDLE ROOMS

5"W X 5.5"H WITH INSERT

MOUNTED WITH MAGNET, PIN OR CUBICLE HANGER

DEPENDING ON WORKSTATIONS SPECIFIED.

ROOM NUMBERS MUST BE RENDERED IN RAISED COPY WITH BRAILLE PER CODE. INSERT TEXT

TO BE APTOS FONT PRINTED ON POLYESTER MEDIA PER DRAWINGS AND CALLOUTS.

W5209.05

GRAPHIC PRINTED ON INSERT

WINDOW SIZE 4.5W X 2.5 H

OPTIONS FOR BACKGROUND

PMS 539C DARK BLUE

OR SILVER

OPTIONS FOR BACKGROUND

PMS 539C DARK BLUE

OR SILVER

GRAPHIC PRINTED ON INSERT

WINDOW SIZE 4.5W X 2.5 H

TECHNICAL EXHIBIT #15

SCALE AS NOTED

DATE 05/20/ 2025

CREATED BY: BK

CHECKED BY: AB

USER AGENCY SIGNAGE FOR LEASING PROJECTS

NOTE EXHIBITS ARE FOR REFERENCE ONLY. CONTRACTOR IS RESPONSIBLE TO MEET APPLICABLE CODES

DETAILS SCALE 6" = 1'-0"

ELEVATIONS SCALE 1/8" = 1'-0"

T:\Administrative\Boiler Plate\Leasing\2.0 Design-Drawings\CAD\LEASING SPACE STANDARDS.dwg, 5/20/2025 3:43:06 PM

CH-O

10'-0"

'-0

TB

D

8W

30x72

6' -0

" C H

-O

10'-0"

'-0

TBD 48W

30x72

6' -0

4' -0

4' -0

MINIMUM 9'-0"

DUPLEX ELECTRICAL OUTLET

18" AFF UNLESS NOTED

QUAD ELECTRICAL OUTLET 18" AFF

UNLESS NOTED. OUTLETS TO BE ALWAYS

ON.

DATA OUTLETS. 2 PER OUTLETS

PER LOCATION

10'-0"

'-0

TABLE

36x72

3'-0" MIN.

5' -0

CH-O

10'-0"

5' -0

'-0

TB

D

8W

30x72

5' -0

5' -0

MONITORS ON ARMS

OR MOUNTED TO WALL

WITH HDMI FOR

MONITOR CONNECTED

TO DOCKING STATION

ON TABLE

TYPICAL OFFICE 100 SQ FT

SCALE 1/4" = 1'- 0"

DATE 10/07/ 2025

CREATED BY: BRK

CHECKED BY: JW

TYPICAL OFFICE AND HUDDLE ROOMS

TECHNICAL EXHIBIT #17

TYPICAL OFFICE 120 SQ FT TYPICAL FLEX OFFICE OR HUDDLE 120 SQ FT

NOTES

· OUTLETS SHOWN ARE TO BE ALWAYS ON.

· SWITCHED OUTLETS TO BE CLEARLY NOTED

· MONITOR ARMS ARE SELECTED BY USER

AGENCY.

EXHIBITS ARE FOR REFERENCE ONLY.

CONTRACTOR IS RESPONSIBLE TO MEET

APPLICABLE CODES INCLUDING ADA COMPLIANCE

T:\Administrative\Boiler Plate\Leasing\2.0 Design-Drawings\CAD\LEASING SPACE STANDARDS.dwg, 10/16/2025 4:21:22 PM

Technical Exhibit 2.2 Typical Transaction Transaction Counter (Ballistic Glass) (1)
Sheets and Views
TE2.2 Ballistic
Technical Exhibit 3 - Perimeter Shelving
Sheets and Views
SK-2.11.2
Technical Exhibit 4 - Typical Chair Rail Detail
Sheets and Views
SK-2.11.3
Technical Exhibit 6 - Interview Room
Sheets and Views
TE 6 TRANSACTION WINDOW
Technical Exhibit 6A- DOR Level 1 Ballistic Glass Interview Rm
Sheets and Views
TE 6 TRANSACTION WINDOW
Technical Exhibit 6B - ADA Interview Room
Sheets and Views
TE 6 ADA -TRANSACTION WIND
Technical Exhibit 9- Dual Way Window Intercom System (1)
Sheets and Views
Intercom TE 9
Technical Exhibit 13 Wellness Room
Sheets and Views
WELLNESS TE13
Technical Exhibit 14 Staff Support]
Sheets and Views
STAFF SUP. TE 14
Technical Exhibit 15 Signage
Sheets and Views
SIGNAGE te15
Technical Exhibit 17 Typical Office and Huddle
Sheets and Views
OFFICE HUDDLE TE17

File details come from the government source that posted it. Updated .