DOR 202610200 Technical Exhibits.pdf
PDF 2 MB Posted
- Attached to
- AD Project #202610200 Massachusetts Department of Revenue, Abington, Attleboro, Berkley, etc.
- Solicitation number
- BD-27-1019-DCP06-OOL01-131501
- Issued by
- Bristol County, Massachusetts
About this file
This technical exhibits document provides detailed design specifications and standards for leased office space for the Massachusetts Department of Revenue (DOR) covering multiple municipalities in southeastern Massachusetts, including Abington, Attleboro, Berkley, Bridgewater, Brockton, and others. The exhibits establish construction and design requirements for approximately 8,500 square feet of usable office area, with flexibility for 7,500 to 10,000 square feet, for a 10-year lease term. The specifications include detailed technical drawings and construction standards for various space types including reception counters with ballistic-resistant glass assemblies, transaction windows with intercom systems, interview rooms, perimeter shelving, staff support areas, wellness rooms, and typical office and huddle room configurations. All specifications emphasize ADA compliance, with detailed notes regarding electrical outlets, data connections, wire management trays, furniture specifications, and finishes. The exhibits reference specific product models such as the Creative Industries Model 1411-S stainless steel deal tray and Retevis RT-9908 intercom systems, with dimensions, clearances, and construction methodologies precisely detailed across multiple technical drawings dated between September 2025 and February 2026.
The technical exhibits establish baseline construction and design standards that contractors must meet or exceed to comply with applicable building codes and ADA guidelines. The architect is designated as responsible for verifying all dimensions and code compliance, while contractors are accountable for meeting all applicable codes including ADA compliance and ensuring proper installation of all components. The document notes that certain items such as the intercom system are to be provided by the user agency or landlord, with specifications for ethernet data jacks to be patched according to standards provided by the user agency. Signage standards are addressed with specific requirements for raised copy and braille, mounted at 60 inches above finish floor with color options of PMS 539C dark blue or silver, and may be procured through Takeform at the specified contact information provided in the exhibits.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| DOR 202610200 WARNING.pdf | ||
| DOR 202610200 Estoppel Certificate.pdf | ||
| DOR 202610200 SNDA.pdf | ||
| DOR 202610200 Ten-Year Lease Proposal Form.docx | DOCX document | |
| DOR 202610200 SAFS.pdf | ||
| DOR 202610200 IFP~1.pdf | ||
| DOR 202610200 RNDA.pdf | ||
| DOR 202610200 10-year Office Lease.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DUPLEX ELECTRICAL OUTLET
18" AFF UNLESS NOTED
DATA OUTLETS. 2 PER OUTLETS PER
LOCATION. 18" AFF UNLESS NOTED
SYMBOL KEY
QUAD ELECTRICAL OUTLET
18" AFF UNLESS NOTED. OUTLET TO BE ALWAYS ON
2.5" GROMMETS
WM
WIRE MANAGEMENT TRAY
5' -0
10" X 12" STAINLESS STEEL DEAL TRAY PROVIDED BY
CONTRACTOR
2' -2
(3) 2.5" GROMMETS ON BOTH COUNTERS AND
THROUGH WALL FOR ELECTRIC AND DATA CORDS FOR
INTERCOM. 12" FROM TRAY . FEED INTO CABLE TRAY.
SPEAKER TO BE INSTALLED AS PER SPECS
COUNTER NOT TO PROJECT MORE THAN 4" FROM THE
WALL. AGENCY TO VALIDATE IF 12" REQUIRED AS A
WRITING SURFACE
1' -8
B
5'-0" CLEARANCE REQUIRED IN FRONT OF RECEPTION
COUNTER FOR PRIVACY
7'-0"A
WM
WM
INTERCOM
SPEAKER
2' -1
0"
WELDED
STEEL FRAME
STAINLESS STEEL DEAL TRAY
PROVIDED BY CONTRACTOR
(12"X10")
SUPPORT AS NEEDED
BALLISTIC GLASS SEE NOTES
1/2" GWB OVER
BALLISTIC FIBERGLASS
ON METAL STUDDING
BALLISTIC GLASS WINDOW
INTERCOM SYSTEM 48" AFF
M
AX
T O
P O
F C
O U
N
TE
R
4' -2
M
IN
IM
U M
G
LA
SS
H
EI
G
H T
7'-0" MINIMUM WIDTH OF GLASS
CEILING HEIGHT
VARIES
2 MINIMUM RECESSED CAN
LIGHTS OVER WORKSURFACE
GROMMET AND
INTERCOM SPEAKER
1/2" GWB OVER
BALLISTIC FIBERGLASS
ON METAL STUDDING
1/2" GWB OVER BALLISTIC
FIBERGLASS ON METAL
STUDDING BOTH SIDES OF
WALL
2' -1
0"
BALLISTIC GLASS SEE
NOTES
DEAL TRAY SEE NOTES
STAFF SIDERECEPTION AREA
1/2" GWB OVER BALLISTIC
FIBERGLASS ON METAL
STUDDING BOTH SIDES OF
WALL
1'-0"
WALL TO UNDERSIDE OF
DECK1'-0"
CEILING HEIGHT PER
PROJECT SPECIFICATIONS
COUNTER SUPPORTS AS
NEEDED
PLASTIC LAMINATE
COUNTERS ON 34" PLYWOOD
SUBSTRATE. LAMINATE ON
ALL EXPOSED SURFACES.
GROMMETS TO BE PROVIDED
WIRE MANAGEMENT TRAY
2 14" EDGE BAND TO
ACOMODATE DEAL TRAY.
2 RECESSED CAN LIGHTS
MIN. OVER WORKSURFACE
WELDED STEEL FRAME, TO
MEET LEVEL 1 BALLISTICS
COUNTER SUPPORTS AS
NEEDED
NOTES FOR EXHIBIT 2.2
· GLASS IN WINDOW TO BE UL 752 LEVEL 1 BALLISTIC RESISTANT LAMINATED GLASS
ASSEMBLY, CONSTRUCTED PER ASTM C1172, AND COMPLIANT WITH ANSI Z97.1
CLASS A AND CPSC 16 CFR 1201 CATEGORY II, AS APPLICABLE. SAFETY GLASS
SHALL CONFORM TO ASTM C1036.
· DEAL TRAY STAINLESS STEEL 12 X 10 DROP IN MODEL TO ALLOW TRANSFER OF
SMALL ITEMS. CREATIVE INDUSTRIES MODEL1411-S OR SIMILAR
· INTERCOM SYSTEM TO BE PROVIDED BY USER AGENCY. SIMILAR TO RETEVIS
RT-9908 WINDOW SPEAKER,WINDOW INTERCOM DUAL-WAY VOICE,WINDOW
SPEAKER INTERCOM SYSTEM. OUTLET, AND 3 GROMMETS TO BE PROVIDED AS
NOTED.
· BOTH SIDES OF WALL BETWEEN AGENCY AND PUBLIC TO BE 1/2" GWB OVER
BALLISTIC FIBERGLASS ON METAL STUDS
· COUNTER DEPTH MINIMUM 12" EACH SIDE. SUPPORTS TO HAVE HOLE TO LOCK
LAPTOP AND CHANNEL FOR WIRE MANAGEMENT
· COUNTER FINISH TO BE SELECTED BY PROJECT ARCHITECT WITH APPROVAL FROM
AGENCY.
· WALL WITH TRANSACTION COUNTER AND GLASS TO DECK
· 4" STRAIGHT VINYL WALL BASE THROUGH OUT
· IF DOOR HAS DOOR CLOSER ROOM IS REQUIRED TO BE 6" LONGER, FOR EACH
DOOR. IF BOTH DOORS HAVE CLOSER ROOM WOULD NEED TO BE MINIMUM OF
12'-0" X 8'-0"
· NOTE DRAWING FOR REFERENCE DETAILS ON GLASS FRAME AND CONFIGURATION
TO BE DETERMINED BY CONTRACTOR.
· DATA JACK FOR ETHERNET CABLE TO BE PATCHED ACCORDING TO
SPECIFICATIONS PROVIDED BY USER AGENCY.
· WIRE MANAGEMENT TRAY TO BE INCLUDED AS SHOWN
NOTE DRAWING IS FOR REFERENCE ONLY ARCHITECT IS RESPONSIBLE TO VERIFY DIMENSIONS AND
CODE COMPLIANCE. ALL GOVERNMENT PROPERTIES ARE TO COMPLY WITH ADA GUIDELINES.
ARCHITECT IS RESPONSIBLE TO CONFIRM THAT ADA ROOM MEETS COMPLIANCE
SCALE AS NOTED
DATE 01/14/2026
CREATED BY: BRK
CHECKED BY: JM/KH
RECEPTION COUNTER WITH BALLISTIC GLASS
TECHNICAL EXHIBIT #2.2
NOTE EXHIBITS ARE FOR REFERENCE ONLY. CONTRACTOR IS
RESPONSIBLE TO MEET APPLICABLE CODESELEVATION A SCALE 1/2" = 1'-0"SECTION BSCALE 1/2" = 1'-0"
PLAN SCALE 3/8" = 1'-0"
T:\Projects\_LEASING EXHIBIT UPDATES\2.0 Design-Drawings\Working\LEASING EXHIBITS_UPDATE 2026.dwg, 1/14/2026 10:32:43 AM
T
Y P
14"
NOTES:
1. VERIFY LOCATION & DEPTH OF ALL SHELVING
WITH AGENCY PRIOR TO INSTALLATION.
2. WHEN CASE FILE SHELVING IS BACK TO BACK
PROVIDE CONST 5/8" PLYWOOD DIVIDERS ENTIRE
LENGTH OF BACK TO BACK SHELVING.
CEILING HEIGHT VARIES
PARTITION
CONSTRUCTION
VARIES
CONST 2x1 WOOD
BLOCKING AT
EACH SHELF TYP
32" O.C. MAX
TECHNICAL EXHIBIT 3
PERIMETER SHELVING
SCALE: NTS
SECTION
SCALE: NTS
ELEVATION
CONST. SHELF CLEAT
3/4" PLYWOOD
SUPPORTS @ 3'-0"
MAX O.C. W/
EDGE BLOCKING
3/4"x 12" CONST.
PLYWOOD SHELVING
(7 TOTAL)
CONST. 1"X3"
SHELF CLEAT
1"x4" CONST WD BASE
W/ 2"x4" BLKG
CONDITION @ 24" & 18"
SHELVING SHOWN DOTTED
4" VINYL STRAIGHT WALL
BASE FOR CARPET
4" VINYL COVE BASE WALL
FOR VINYL COMPOSITE TILE
O
C
CEILING HEIGHT
VARIES
1"x4" CHAIR RAILCONST WD
BLOCKING
STUDDING
TECHNICAL EXHIBIT 4
TYPICAL CHAIR RAIL DETAIL
NOT TO SCALE
FOR REFERENCE ONLY
VERIFY ALL DIMENSIONS
8'-0"
'-6
1'
-7
2.5" GROMMET ON
STAFF SIDE FOR
ELECTRIC AND
DATA CORDS. 12"
FROM TRAY .
2.5" GROMMET ON PUBLIC
SIDE FOR COMPUTER LOCK,
ELECTRIC AND DATA CORDS.
12" FROM TRAY . FEED INTO
CABLE TRAY. OPTIONAL
MONITOR ARM WITH
KEYBOARD.
1' -0
STAFF SIDE
5' -3
A
LAPTOP
AND DOCK NIC
1'-0"
3'-0"
PUBLIC SIDE
LAPTOP
AND DOCK NIC
QUAD ELECTRICAL OUTLET
18" AFF UNLESS NOTED
DATA OUTLETS. 2 PER OUTLETS PER LOCATION,
M
IN
IM
U
M
WM
WM
WIRE MANAGEMENT TRAY
LAPTOP
AND DOCK
NIC
3' -6
BALLISTIC GLASS SEE
NOTES
DEAL TRAY SEE
NOTES
PUBLIC
SIDE
STAFF
SIDE
COUNTER
SUPPORTS SEE
NOTES
1/2" GWB OVER BALLISTIC
FIBERGLASS ON METAL STUDDING
BOTH SIDES OF WALL
1/2" GWB OVER BALLISTIC
FIBERGLASS ON METAL STUDDING
BOTH SIDES OF WALL
3' -6
3'
-6
CEILING HEIGHT VARIES
WELDED STEEL
FRAME
STAINLESS STEEL DEAL TRAY
PROVIDED BY CONTRACTOR
(12"X10")
SUPPORTS AS
NEEDED
REQUIRED TO
LOCK LAPTOP
BALLISTIC GLASS SEE NOTES
1/2" GWB OVER
BALLISTIC FIBERGLASS
ON METAL STUDDING
2.5" GROMMET IN WALL
WIRE MANAGEMENT TRAY
MOUNTED UNDER COUNTER
1/2" GWB OVER BALLISTIC FIBERGLASS
ON METAL STUDDING
3'-0"
NOTES
· GLASS IN WINDOW TO BE UL 752 LEVEL 1 BALLISTIC RESISTANT LAMINATED GLASS
ASSEMBLY, CONSTRUCTED PER ASTM C1172, AND COMPLIANT WITH ANSI Z97.1
CLASS A AND CPSC 16 CFR 1201 CATEGORY II, AS APPLICABLE. SAFETY GLASS
SHALL CONFORM TO ASTM C1036.
· DEAL TRAY STAINLESS STEEL 12 X 10 DROP IN MODEL TO ALLOW TRANSFER OF
SMALL ITEMS. CREATIVE INDUSTRIES MODEL1411-S OR SIMILAR
· INTERCOM SYSTEM TO BE PROVIDED BY USER AGENCY. SIMILAR TO RETEVIS
RT-9908 WINDOW SPEAKER,WINDOW INTERCOM DUAL-WAY VOICE,WINDOW
SPEAKER INTERCOM SYSTEM. OUTLET, AND 3 GROMMETS TO BE PROVIDED AS
NOTED.
· BOTH SIDES OF WALL BETWEEN AGENCY AND PUBLIC TO BE 1/2" GWB OVER
BALLISTIC FIBERGLASS ON METAL STUDS
· COUNTER DEPTH MINIMUM 12" EACH SIDE. SUPPORTS TO HAVE HOLE TO LOCK
LAPTOP AND CHANNEL FOR WIRE MANAGEMENT
· COUNTER FINISH TO BE SELECTED BY PROJECT ARCHITECT WITH APPROVAL FROM
AGENCY.
· WALL WITH TRANSACTION COUNTER AND GLASS TO DECK
· 4" STRAIGHT VINYL WALL BASE THROUGH OUT
· IF DOOR HAS DOOR CLOSER ROOM IS REQUIRED TO BE 6" LONGER, FOR EACH
DOOR. IF BOTH DOORS HAVE CLOSER ROOM WOULD NEED TO BE MINIMUM OF
12'-0" X 8'-0"
· NOTE DRAWING FOR REFERENCE DETAILS ON GLASS FRAME AND CONFIGURATION
TO BE DETERMINED BY CONTRACTOR.
· DATA JACK FOR ETHERNET CABLE TO BE PATCHED ACCORDING TO
SPECIFICATIONS PROVIDED BY USER AGENCY.
· WIRE MANAGEMENT TRAY TO BE INCLUDED AS SHOWN
NOTE DRAWING IS FOR REFERENCE ONLY ARCHITECT IS RESPONSIBLE TO VERIFY DIMENSIONS AND
CODE COMPLIANCE. ALL GOVERNMENT PROPERTIES ARE TO COMPLY WITH ADA GUIDELINES.
ARHCITECT IS RESPONSIBLE TO CONFIRM THAT ADA ROOM MEETS COMPLIANCE
SCALE AS NOTED
DATE 01/12/ 2026
CREATED BY: BRK
CHECKED BY: MJ/JM
TYPICAL TRANSACTION COUNTER FOR
INTERVIEW ROOM
TECHINICAL EXHIBIT #6
SECTION SCALE 1/2" = 1'-0"ELEVATION STAFF SIDE
PLAN SCALE 1/4" = 1'-0"
SCALE 1/2" = 1'-0"
NOTES
T:\Projects\_LEASING EXHIBIT UPDATES\2.0 Design-Drawings\Working\DOR EXHIBITS_UPDATES.dwg, 1/12/2026 11:32:37 AM
8'-0"
'-6
1'
-7
2.5" GROMMET ON
STAFF SIDE FOR
ELECTRIC AND
DATA CORDS. 12"
FROM TRAY .
2.5" GROMMET ON PUBLIC
SIDE FOR COMPUTER LOCK,
ELECTRIC AND DATA CORDS.
12" FROM TRAY . FEED INTO
CABLE TRAY. OPTIONAL
MONITOR ARM WITH
KEYBOARD.
1' -6
STAFF SIDE
A LAPTOP
AND DOCK NIC
3'-0"
PUBLIC SIDE
QUAD ELECTRICAL OUTLET
18" AFF UNLESS NOTED
DATA OUTLETS. 2 PER OUTLETS PER LOCATION,
M
IN
IM
U
M
WM
WM
WIRE MANAGEMENT TRAY
LAPTOP
AND DOCK
NIC
4' -0
3' -6
BALLISTIC GLASS SEE
NOTES
DEAL TRAY SEE
NOTES
PUBLIC
SIDE
STAFF
SIDE
COUNTER
SUPPORTS SEE
NOTES
1/2" GWB OVER BALLISTIC
FIBERGLASS ON METAL STUDDING
BOTH SIDES OF WALL
1/2" GWB OVER BALLISTIC
FIBERGLASS ON METAL STUDDING
BOTH SIDES OF WALL
GROMMET
THROUGH WALL
3' -6
3'
-6
CEILING HEIGHT VARIES
WELDED STEEL
FRAME
STAINLESS STEEL DEAL TRAY
PROVIDED BY CONTRACTOR
(12"X10")
SUPPORTS AS
NEEDED
REQUIRED TO
LOCK LAPTOP
BALLISTIC GLASS SEE NOTES
1/2" GWB OVER
BALLISTIC FIBERGLASS
ON METAL STUDDING
2.5" GROMMET IN WALL
WIRE MANAGEMENT TRAY
MOUNTED UNDER COUNTER
1/2" GWB OVER BALLISTIC FIBERGLASS
ON METAL STUDDING
3'-0"
NOTES
· GLASS IN WINDOW TO BE UL 752 LEVEL 1 BALLISTIC RESISTANT LAMINATED GLASS
ASSEMBLY, CONSTRUCTED PER ASTM C1172, AND COMPLIANT WITH ANSI Z97.1
CLASS A AND CPSC 16 CFR 1201 CATEGORY II, AS APPLICABLE. SAFETY GLASS
SHALL CONFORM TO ASTM C1036.
· DEAL TRAY STAINLESS STEEL 12 X 10 DROP IN MODEL TO ALLOW TRANSFER OF
SMALL ITEMS. CREATIVE INDUSTRIES MODEL1411-S OR SIMILAR
· INTERCOM SYSTEM TO BE PROVIDED BY LANDLORD, AGENCY TO CONFIRM
SPECIFICATIONS SIMILAR TO RETEVIS RT-9908 WINDOW SPEAKER,WINDOW
INTERCOM DUAL-WAY VOICE,WINDOW SPEAKER INTERCOM SYSTEM. OUTLET, AND
3 GROMMETS TO BE PROVIDED AS NOTED.
· BOTH SIDES OF WALL BETWEEN AGENCY AND PUBLIC TO BE 1/2" GWB OVER
BALLISTIC FIBERGLASS ON METAL STUDS
· COUNTER DEPTH MINIMUM 12" EACH SIDE. SUPPORTS TO HAVE HOLE TO LOCK
LAPTOP AND CHANNEL FOR WIRE MANAGEMENT
· COUNTER FINISH TO BE SELECTED BY PROJECT ARCHITECT WITH APPROVAL FROM
AGENCY.
· WALL WITH TRANSACTION COUNTER AND GLASS TO DECK
· 4" STRAIGHT VINYL WALL BASE THROUGH OUT
· IF DOOR HAS DOOR CLOSER ROOM IS REQUIRED TO BE 6" LONGER, FOR EACH
DOOR. IF BOTH DOORS HAVE CLOSER ROOM WOULD NEED TO BE MINIMUM OF
12'-0" X 8'-0"
· NOTE DRAWING FOR REFERENCE DETAILS ON GLASS FRAME AND CONFIGURATION
TO BE DETERMINED BY CONTRACTOR.
· DATA JACK FOR ETHERNET CABLE TO BE PATCHED ACCORDING TO
SPECIFICATIONS PROVIDED BY USER AGENCY.
· WIRE MANAGEMENT TRAY TO BE INCLUDED AS SHOWN
NOTE DRAWING IS FOR REFERENCE ONLY ARCHITECT IS RESPONSIBLE TO VERIFY
DIMENSIONS AND CODE COMPLIANCE. ALL GOVERNMENT PROPERTIES ARE TO
COMPLY WITH ADA GUIDELINES. ARCHITECT IS RESPONSIBLE TO CONFIRM THAT
ADA ROOM MEETS COMPLIANCE. NOTE DOOR CLOSER REQUIRED IF 54"
CLEARANCE IS REQUIRED.
SCALE AS NOTED
DATE 02/12/ 2026
CREATED BY: BRK
CHECKED BY: MJ/JM
TYPICAL TRANSACTION COUNTER FOR
INTERVIEW ROOM
TECHINICAL EXHIBIT #6A
SECTION SCALE 1/2" = 1'-0"ELEVATION STAFF SIDE
PLAN SCALE 1/4" = 1'-0"
SCALE 1/2" = 1'-0"
T:\Projects\_LEASING EXHIBIT UPDATES\2.0 Design-Drawings\Working\DOR EXHIBITS_UPDATES.dwg, 2/19/2026 9:57:50 AM
A
STAFF SIDE
LAPTOP
AND DOCK
NIC
1' -7
1'-0"
3'-0"
NOTE 5' TURNING
RADIUS MINIMUM ON
EACH SIDE OF ROOM
BALLISTIC
GLASS SEE
NOTES
1' -0
8'-0"
'-0
PUBLIC SIDE
4' -0
M
IN
IM
U
M
WM
QUAD ELECTRICAL OUTLET
18" AFF UNLESS NOTED
DATA OUTLETS. 2 PER OUTLETS PER LOCATION,
WM
WIRE MANAGEMENT TRAY
2.5" GROMMET ON PUBLIC
AND STAFF SIDE FOR
COMPUTER LOCK, ELECTRIC
AND DATA CORDS. 12" FROM
TRAY . FEED INTO CABLE
TRAY. OPTIONAL MONITOR
ARM WITH KEYBOARD.
1/2" GWB OVER BALLISTIC
FIBERGLASS ON METAL STUDDING
BOTH SIDES OF WALL
2' -6
BALLISTIC GLASS SEE
NOTES
DEAL TRAY SEE
NOTES
COUNTER
SUPPORTS SEE
NOTES
STAFF SIDE
1/2" GWB OVER BALLISTIC
FIBERGLASS ON METAL STUDDING
BOTH SIDES OF WALL
2' -6
4'
-6
CEILING HEIGHT VARIES
WELDED STEEL
FRAME
STAINLESS STEEL DEAL TRAY
PROVIDED BY CONTRACTOR
(12"X10")
SUPPORT AS NEEDED
BALLISTIC GLASS SEE NOTES
1/2" GWB OVER
BALLISTIC FIBERGLASS
ON METAL STUDDING
M
AX
T O
P O
F C
O U
N
TE
R
2.5" GROMMET IN WALL
WIRE MANAGEMENT TRAY MOUNTED
UNDER COUNTER. GROMMET TO CLEAR
CABLE MANAGEMENT TRAY
1' -8
NOTES
· GLASS IN WINDOW TO BE UL 752 LEVEL 1 BALLISTIC RESISTANT LAMINATED GLASS
ASSEMBLY, CONSTRUCTED PER ASTM C1172, AND COMPLIANT WITH ANSI Z97.1
CLASS A AND CPSC 16 CFR 1201 CATEGORY II, AS APPLICABLE. SAFETY GLASS
SHALL CONFORM TO ASTM C1036.
· DEAL TRAY STAINLESS STEEL 12 X 10 DROP IN MODEL TO ALLOW TRANSFER OF
SMALL ITEMS. CREATIVE INDUSTRIES MODEL1411-S OR SIMILAR
· INTERCOM SYSTEM TO BE PROVIDED BY USER AGENCY. SIMILAR TO RETEVIS
RT-9908 WINDOW SPEAKER,WINDOW INTERCOM DUAL-WAY VOICE,WINDOW
SPEAKER INTERCOM SYSTEM. OUTLET, AND 3 GROMMETS TO BE PROVIDED AS
NOTED.
· BOTH SIDES OF WALL BETWEEN AGENCY AND PUBLIC TO BE 1/2" GWB OVER
BALLISTIC FIBERGLASS ON METAL STUDS
· COUNTER DEPTH MINIMUM 12" EACH SIDE. SUPPORTS TO HAVE HOLE TO LOCK
LAPTOP AND CHANNEL FOR WIRE MANAGEMENT
· COUNTER FINISH TO BE SELECTED BY PROJECT ARCHITECT WITH APPROVAL FROM
AGENCY.
· WALL WITH TRANSACTION COUNTER AND GLASS TO DECK
· 4" STRAIGHT VINYL WALL BASE THROUGH OUT
· IF DOOR HAS DOOR CLOSER ROOM IS REQUIRED TO BE 6" LONGER, FOR EACH
DOOR. IF BOTH DOORS HAVE CLOSER ROOM WOULD NEED TO BE MINIMUM OF
12'-0" X 8'-0"
· NOTE DRAWING FOR REFERENCE DETAILS ON GLASS FRAME AND CONFIGURATION
TO BE DETERMINED BY CONTRACTOR.
· DATA JACK FOR ETHERNET CABLE TO BE PATCHED ACCORDING TO
SPECIFICATIONS PROVIDED BY USER AGENCY.
· WIRE MANAGEMENT TRAY TO BE INCLUDED AS SHOWN
NOTE DRAWING IS FOR REFERENCE ONLY ARCHITECT IS RESPONSIBLE TO VERIFY DIMENSIONS AND
CODE COMPLIANCE. ALL GOVERNMENT PROPERTIES ARE TO COMPLY WITH ADA GUIDELINES.
ARHCITECT IS RESPONSIBLE TO CONFIRM THAT ADA ROOM MEETS COMPLIANCE
SCALE AS NOTED
DATE 01/12/2026
CREATED BY: BRK
CHECKED BY: CB, MJ/JM
ADA COMPLIANT TRANSACTION COUNTER
FOR INTERVIEW ROOM
TECHINICAL EXHIBIT #6B
SECTION SCALE 1/2" = 1'-0"ELEVATION STAFF SIDE
PLAN SCALE 1/4" = 1'-0"
SCALE 1/2" = 1'-0"
T:\Projects\_LEASING EXHIBIT UPDATES\2.0 Design-Drawings\Working\DOR EXHIBITS_UPDATES.dwg, 1/12/2026 1:50:40 PM
INTERCOM PURCHASED BY USER AGENCY. LAST UNIT
PURCHASED FROM AMAZON.COM : RETEVIS RT-9908
WINDOW SPEAKER,WINDOW INTERCOM DUAL-WAY
VOICE,WINDOW SPEAKER INTERCOM SYSTEM FOR
BUSINESS,BANK,TICKET WINDOW : ELECTRONICS
SCALE NTS
DATE 09/04/ 2025
CREATED BY: BRK
CHECKED BY:
DUAL WAY WINDOW INTERCOM SYSTEM
NOTE EXHIBITS ARE FOR REFERENCE ONLY. CONTRACTOR IS RESPONSIBLE TO MEET APPLICABLE CODES INCLUDING ADA COMPLIANCE
TECHNICAL EXHIBIT # 9
T:\Administrative\Boiler Plate\Leasing\2.0 Design-Drawings\CAD\LEASING SPACE STANDARDS.dwg, 9/5/2025 3:02:57 PM
42 AFF
MINUMUM
TABLE
1'-6"
CLEAR
RESILIENT
FLOORING
CARPET
2'
-1 0"
8'-0"
REFRIGERATOR
NIC
34" MINIMUM WIDTH AND
24" MINIMUM HEIGHT
CLEARANCE. 17" KNEE
SPACE MINIMUM.
3' -6
S
EC
TI
O
N A
1' -6
2' -3
2' -1
0"
1'-5"
9"
REMOVABLE
PANEL
ROOMS WITH PLUMBING: KITCHEN / WELLNESS
DUPLEX ELECTRICAL
OUTLET
18" AFF UNLESS NOTED
DATA OUTLETS. 2 PER
OUTLETS PER
LOCATION
WELLNESS ROOM NOTES
· FURNITURE SHOWN TO BE PROVIDED BY TENANT
· LIGHTS TO BE DIMMABLE
· FLOORING AT SINK TO BE RESILIENT FLOORING
· IF SIDE LIGHT PROVIDED ENTIRE WINDOW TO BE
PRIVACY FILM
· MIRROR & BULLETIN BOARD NOT PROVIDED BY
CONTRACTOR
WELLNESS ROOM
TECHNICAL EXHIBIT #13
PLAN TYPICAL 80 SQ FT
SCALE 1/2" =1'-0"
SCALE 1/4" = 1'-0"
SCALE as noted
DATE 10/07/2025
CREATED BY: BK
CHECKED BY : CB and EA
SINK SECTION SCALE 1/2" = 1'-0"
ELEVATION OF MILLWORK WELLNESS ROOM
EXHIBITS ARE FOR REFERENCE ONLY. CONTRACTOR IS RESPONSIBLE TO MEET APPLICABLE CODES
T:\Administrative\Boiler Plate\Leasing\2.0 Design-Drawings\CAD\LEASING SPACE STANDARDS.dwg, 10/7/2025 3:17:15 PM
AutoCAD SHX Text
REF
2' -1
0"3' -6
1' -6
2'-0" 1'-6"3'-0"
1' -3
2'
-6
3'-0"
24" MINIMUM HEIGHT
CLEARANCE. 17" KNEE
SPACE MINIMUM.
S
EC
TI
O
N A
1'-6"
DUPLEX ELECTRICAL OUTLET
18" AFF UNLESS NOTED
DATA OUTLETS. 2 PER OUTLETS PER LOCATION
H20
MARKER BOARD AND/OR
TACK BOARD TBD
8' -0
"C H
C H
C
H 07C
H
42"
AFF
42"
AFF
QUENCH WATER COOLER
AND WALL PHONE TBD
A
MARKER BOARD AND
TACK BOARD ALIGN
BOTTOM
WITH COUNTER
30 x 60
30 x 60
30 x 60
A
42"
AFF
42"
AFF
H20
WALL PHONE TBD
QUENCH WATER COOLER
2' -3
2' -1
0"
1'-5"
9"
REMOVABLE
PANEL
SCALE AS NOTED
DATE 06/06/2025
CREATED BY: BRK
CHECKED BY: CB
STAFF SUPPORT
TECHNICAL EXHIBIT #14
ELEVATION A OF MILLWORK STAFF SUPPORT ROOM
PLAN KEY
SCALE 1/2" =1'-0"
SCALE 1/4" =1'-0"TYPICAL PLAN 200 SQ FT STAFF SUPPORT SPACE
SCALE 1/4" =1'-0"TYPICAL PLAN 400 SQ FT STAFF SUPPORT SPACE
NOTES
PLANS SHOW PREFERRED OPTION FOR QUENCH WATER COOLERS BY MOST AGENCIES . VALIDATE
LOCATION WITH AGENCY. SOME AGENCIES PREFER COUNTER TOP OPTIONS WHEN SPACE PERMITS
NOTE EXHIBITS ARE FOR REFERENCE ONLY. CONTRACTOR IS RESPONSIBLE TO MEET APPLICABLE CODES INCLUDING ADA COMPLIANCE
SINK SECTION A SCALE 1/2" = 1'-0"
T:\Administrative\Boiler Plate\Leasing\2.0 Design-Drawings\CAD\LEASING SPACE STANDARDS.dwg, 6/3/2025 5:06:37 PM
AutoCAD SHX Text
REFRIGERATOR NIC
WALL WITH SIDELIGHT WALL AND SIDELIGHTWALL WITH NO SIDELIGHT
AF
F
SIGNAGE - INSTALLATION FOR PERMANENT IDENTIFICATION OF WALLED SPACES (WALL/GLASS) Mounting height shall be 60" above the finish floor (AFF) measured to the baseline of the raised text.
NOTE: the above recommended placement is intended to meet the sign location requirements of the 2010 ADA standards. sec.703.4.1
Sign alignment to be mounted on surface adjacent to the latch side of the door, within 2" - 4" from the door trim.
NOTE: The above recommended placement is intended to meet the sign location requirements of the 2010 ADA standards. sec.703.4.2
Conference
Conference
Conference
PLACE SIGN ON SIDELIGHT PLACE SIGN ON WALL PLACE SIGN ON WALL
2" - 4" FROM
FRAME
2" - 4" FROM
FRAME
2" - 4" FROM
FRAME
INTERIOR SIGNAGE STANDARD
NOTE BACKERS REQUIRED WHEN MOUNTED ON GLASS. BACKER COLOR TO BE CONFIRMED BY AGENCY.
CONTRACTOR RESPONSIBLE TO MEET ADA COMPLIANCE ON ALL SIGNS. INCLUDING INSTALLATION.
ROOM NUMBERS MUST BE RENDERED IN RAISED COPY WITH BRAILLE PER CODE AND DRAWINGS ABOVE. INSERT TEXT TO BE APTOS FONT PRINTED ON POLYESTER MEDIA PER DRAWINGS AND CALLOUTS. ALL SIGNS TO BE POSTED BY CONTRACTOR. ADDITIONAL MATERIAL AND PRINTING INSTRUCTIONS TO BE SUPPLIED TO AGENCY FOR FUTURE SIGNS.
SIGNS CAN BE PURCHASED THROUGH TAKEFORM STYLE VIVID (TAKEFORM.NET). ORDERS AND QUESTIONS CAN BE PLACED BY EMAILING MIKE R. HUNGERFORD 1.800.528.1398 MRH@TAKEFORM.NET. FINAL SIGNAGE OPTIONS AND
SIGNS TO BE SUBMITTED TO DCAMM PROJECT MANGER FOR APPROVAL.
TAKEFORM ROOM SIGNS ARE TYPE J.3B VVAW-01001105-R9DO1. TAKEFORM COLROS DARK BLUE PMS 539C OR SILVER
CMYK 8,9,5,35
TAKEFORM WORKSATION SIGNS ARE TYPE L.b VV1AW-01000701-R9D01
THIS IS FOR INTERNAL AGENCY SPACE ONLY. THESE SIGNS ARE NOT APPLICABLE FOR BATHROOM OR BUILDING CORE
SIGNS
Conference
TYPICAL WORKSTATION SIGNS
5"W X 3.5"H WITH INSERT
MOUNTED WITH MAGNET, PIN OR CUBICLE HANGER
DEPENDING ON WORKSTATIONS SPECIFIED
TYPICAL OFFICE SIGNS
CONFERENCE, OFFICES, FOCUS ROOMS, PHONE ROOMS, HUDDLE ROOMS
5"W X 5.5"H WITH INSERT
MOUNTED WITH MAGNET, PIN OR CUBICLE HANGER
DEPENDING ON WORKSTATIONS SPECIFIED.
ROOM NUMBERS MUST BE RENDERED IN RAISED COPY WITH BRAILLE PER CODE. INSERT TEXT
TO BE APTOS FONT PRINTED ON POLYESTER MEDIA PER DRAWINGS AND CALLOUTS.
W5209.05
GRAPHIC PRINTED ON INSERT
WINDOW SIZE 4.5W X 2.5 H
OPTIONS FOR BACKGROUND
PMS 539C DARK BLUE
OR SILVER
OPTIONS FOR BACKGROUND
PMS 539C DARK BLUE
OR SILVER
GRAPHIC PRINTED ON INSERT
WINDOW SIZE 4.5W X 2.5 H
TECHNICAL EXHIBIT #15
SCALE AS NOTED
DATE 05/20/ 2025
CREATED BY: BK
CHECKED BY: AB
USER AGENCY SIGNAGE FOR LEASING PROJECTS
NOTE EXHIBITS ARE FOR REFERENCE ONLY. CONTRACTOR IS RESPONSIBLE TO MEET APPLICABLE CODES
DETAILS SCALE 6" = 1'-0"
ELEVATIONS SCALE 1/8" = 1'-0"
T:\Administrative\Boiler Plate\Leasing\2.0 Design-Drawings\CAD\LEASING SPACE STANDARDS.dwg, 5/20/2025 3:43:06 PM
CH-O
10'-0"
'-0
TB
D
8W
30x72
6' -0
" C H
-O
10'-0"
'-0
TBD 48W
30x72
6' -0
4' -0
4' -0
MINIMUM 9'-0"
DUPLEX ELECTRICAL OUTLET
18" AFF UNLESS NOTED
QUAD ELECTRICAL OUTLET 18" AFF
UNLESS NOTED. OUTLETS TO BE ALWAYS
ON.
DATA OUTLETS. 2 PER OUTLETS
PER LOCATION
10'-0"
'-0
TABLE
36x72
3'-0" MIN.
5' -0
CH-O
10'-0"
5' -0
'-0
TB
D
8W
30x72
5' -0
5' -0
MONITORS ON ARMS
OR MOUNTED TO WALL
WITH HDMI FOR
MONITOR CONNECTED
TO DOCKING STATION
ON TABLE
TYPICAL OFFICE 100 SQ FT
SCALE 1/4" = 1'- 0"
DATE 10/07/ 2025
CREATED BY: BRK
CHECKED BY: JW
TYPICAL OFFICE AND HUDDLE ROOMS
TECHNICAL EXHIBIT #17
TYPICAL OFFICE 120 SQ FT TYPICAL FLEX OFFICE OR HUDDLE 120 SQ FT
NOTES
· OUTLETS SHOWN ARE TO BE ALWAYS ON.
· SWITCHED OUTLETS TO BE CLEARLY NOTED
· MONITOR ARMS ARE SELECTED BY USER
AGENCY.
EXHIBITS ARE FOR REFERENCE ONLY.
CONTRACTOR IS RESPONSIBLE TO MEET
APPLICABLE CODES INCLUDING ADA COMPLIANCE
T:\Administrative\Boiler Plate\Leasing\2.0 Design-Drawings\CAD\LEASING SPACE STANDARDS.dwg, 10/16/2025 4:21:22 PM
| Technical Exhibit 2.2 Typical Transaction Transaction Counter (Ballistic Glass) (1) |
| Sheets and Views |
| TE2.2 Ballistic |
| Technical Exhibit 3 - Perimeter Shelving |
| Sheets and Views |
| SK-2.11.2 |
| Technical Exhibit 4 - Typical Chair Rail Detail |
| Sheets and Views |
| SK-2.11.3 |
| Technical Exhibit 6 - Interview Room |
| Sheets and Views |
| TE 6 TRANSACTION WINDOW |
| Technical Exhibit 6A- DOR Level 1 Ballistic Glass Interview Rm |
| Sheets and Views |
| TE 6 TRANSACTION WINDOW |
| Technical Exhibit 6B - ADA Interview Room |
| Sheets and Views |
| TE 6 ADA -TRANSACTION WIND |
| Technical Exhibit 9- Dual Way Window Intercom System (1) |
| Sheets and Views |
| Intercom TE 9 |
| Technical Exhibit 13 Wellness Room |
| Sheets and Views |
| WELLNESS TE13 |
| Technical Exhibit 14 Staff Support] |
| Sheets and Views |
| STAFF SUP. TE 14 |
| Technical Exhibit 15 Signage |
| Sheets and Views |
| SIGNAGE te15 |
| Technical Exhibit 17 Typical Office and Huddle |
| Sheets and Views |
| OFFICE HUDDLE TE17 |