Door_and_Window_Index_and_Meassurements_2.0.xlsx

XLSX spreadsheet 20 KB Posted

Attached to
Comm Dev Doors and Windows: Rev 3
Solicitation number
31-2102-D/W
Issued by
Kittitas County, Washington

About this file

The provided file is a Door and Window Index spreadsheet for Lewis County's new Community Development Building project in Washington state. The document details specifications for 28 interior doors, including their dimensions (consistently 3'0" wide by 86" high), swing direction (left-hand/right-hand), wall thickness, and door type (6 full lite, 8 half lite, 14 solid). The doors are constructed of CVG Fir and are designated for various rooms such as public restrooms, conference rooms, offices, hearing rooms, and utility spaces like server rooms and electrical closets. Additionally, the spreadsheet includes window measurements for select rooms, with most windows measuring 2' wide by 5' high.

The project appears to be a comprehensive interior door and window package procurement for a new county facility, with a focus on pre-finished, pre-hung wooden components. While specific pricing details are not included in the document, the extensive specifications suggest a detailed, precise procurement process. The index provides comprehensive technical details for each door, including handset finish, hardware preparation, and specific room assignments, indicating a structured approach to the building's interior design and functionality. The document serves as a critical technical specification sheet for potential vendors bidding on the Lewis County Community Development Building project.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

RoomDoor SizeRough HeightSwingFL/HL/SWall ThicknessSlab ThicknessSet Back HandlsetFinishDoor Hardware PrepDetails
1003'0"86"LHS4-3/4"1-3/4"2-3/4"CVG FirDouble BorePublic Restroom
102A3'0"86"LHS4-3/4"1-3/4"2-3/4"CVG FirNAPlan Review Room
102B3'0"86"RHFL4-3/4"1-3/4"2-3/4"CVG FirNAPlan Review Room
1033'086"RHFL8-3/4"1-3/4"2-3/4"CVG FirNAConference Room
1043'0"86"RHFL8-3/4"1-3/4"2-3/4"CVG FirNAOffice Manager
1053'0"86"RHFL8-3/4"1-3/4"2-3/4"CVG FirNADirectors Office
1063'0"86"RHS6-3/4"1-3/4"2-3/4"CVG FirDouble BoreRestroom
1073'0"86"LHS6-3/4"1-3/4"2-3/4"CVG FirDouble BoreRestroom
1083'0"86"LHS6-3/4"1-3/4"2-3/4"CVG FirDouble BoreRestroom
1093'0"86"LHS6-3/4"1-3/4"2-3/4"CVG FirDouble BoreRestroom
1103'0"86"LHS6-3/4"1-3/4"2-3/4"CVG FirDouble BoreRestroom
1113'0"86"LHS4-3/4"1-3/4"2-3/4"CVG FirNAJanitorial Closet
1123'0"86"LHS4-3/4"1-3/4"2-3/4"CVG FirNALactation Room
1133'0"86"RHHL9-1/4"1-3/4"2-3/4"CVG FirNAStorage
1173'0"86"LHS9-1/4"1-3/4"2-3/4"CVG FirNAElectrical
118A3'0"86"RHS4-3/4"1-3/4"2-3/4"CVG FirNAShower
1183'0"86"RHS9-1/4""1-3/4"2-3/4"CVG FirNAMud Room
1203'0"86"LHS5-1/4"1-3/4"2-3/4"CVG FirNASupplies
1213'0"86"RHFL5-1/4"1-3/4"2-3/4"CVG FirNABreak Room
1223'0"86"RHFL5-1/4"1-3/4"2-3/4"CVG FirNASmall Conference Room
123A3'0"86"RHFL8-3/4"1-3/4"2-3/4"CVG FirNAHearing Room
123B3'0"86"LHFL12-3/4"1-3/4"2-3/4"CVG FirNAHearing Room
1243'0"86"RHHL8-3/4"1-3/4"2-3/4"CVG FirNAOffice
1253'0"86"RHHL8-3/4"1-3/4"2-3/4"CVG FirNAOffice
1263'0"86"RHHL8-3/4"1-3/4"2-3/4"CVG FirNAOffice
1273'0"86"LHHL8-3/4"1-3/4"2-3/4"CVG FirNAOffice
1293'0"86"RHHL8-3/4"1-3/4"2-3/4"CVG FirNAOffice
1303'0"86"RHS4-3/4"1-3/4"2-3/4"CVG FirNAServer Room
Total Doors28
Full Lite FL6
Half Lite HL8
Solid14
RHLH
Window #Window WidthWindow HeightWall Thickness# of WindowsDetails
100NAPublic Restroom
102A2'5'8-3/4"1Plan Review Room
102BNAPlan Review Room
1032'5'8-3/4"2Conference Room
1042'5'8-3/4"1Office Manager
105NADirectors Office
106NARestroom
107NARestroom
108NARestroom
109NARestroom
110NARestroom
111NAJanitorial Closet
112NALactation Room
113NAStorage
117NAElectrical
118ANAShower
118NAMud Room
120NASupplies
121NABreak Room
1222'5'4-3/4"2Small Conference Room
123AHearing Room
123B4'18"12-3/4"3Hearing Room
124NAOffice
125NAOffice
126NAOffice
127NAOffice
129NAOffice
130NAServer Room

File details come from the government source that posted it. Updated .