The provided file is a Door and Window Index spreadsheet for Lewis County's new Community Development Building project in Washington state. The document details specifications for 28 interior doors, including their dimensions (consistently 3'0" wide by 86" high), swing direction (left-hand/right-hand), wall thickness, and door type (6 full lite, 8 half lite, 14 solid). The doors are constructed of CVG Fir and are designated for various rooms such as public restrooms, conference rooms, offices, hearing rooms, and utility spaces like server rooms and electrical closets. Additionally, the spreadsheet includes window measurements for select rooms, with most windows measuring 2' wide by 5' high.
The project appears to be a comprehensive interior door and window package procurement for a new county facility, with a focus on pre-finished, pre-hung wooden components. While specific pricing details are not included in the document, the extensive specifications suggest a detailed, precise procurement process. The index provides comprehensive technical details for each door, including handset finish, hardware preparation, and specific room assignments, indicating a structured approach to the building's interior design and functionality. The document serves as a critical technical specification sheet for potential vendors bidding on the Lewis County Community Development Building project.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Room | Door Size | Rough Height | Swing | FL/HL/S | Wall Thickness | Slab Thickness | Set Back Handlset | Finish | Door Hardware Prep | Details |
| 100 | 3'0" | 86" | LH | S | 4-3/4" | 1-3/4" | 2-3/4" | CVG Fir | Double Bore | Public Restroom |
| 102A | 3'0" | 86" | LH | S | 4-3/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Plan Review Room |
| 102B | 3'0" | 86" | RH | FL | 4-3/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Plan Review Room |
| 103 | 3'0 | 86" | RH | FL | 8-3/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Conference Room |
| 104 | 3'0" | 86" | RH | FL | 8-3/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Office Manager |
| 105 | 3'0" | 86" | RH | FL | 8-3/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Directors Office |
| 106 | 3'0" | 86" | RH | S | 6-3/4" | 1-3/4" | 2-3/4" | CVG Fir | Double Bore | Restroom |
| 107 | 3'0" | 86" | LH | S | 6-3/4" | 1-3/4" | 2-3/4" | CVG Fir | Double Bore | Restroom |
| 108 | 3'0" | 86" | LH | S | 6-3/4" | 1-3/4" | 2-3/4" | CVG Fir | Double Bore | Restroom |
| 109 | 3'0" | 86" | LH | S | 6-3/4" | 1-3/4" | 2-3/4" | CVG Fir | Double Bore | Restroom |
| 110 | 3'0" | 86" | LH | S | 6-3/4" | 1-3/4" | 2-3/4" | CVG Fir | Double Bore | Restroom |
| 111 | 3'0" | 86" | LH | S | 4-3/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Janitorial Closet |
| 112 | 3'0" | 86" | LH | S | 4-3/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Lactation Room |
| 113 | 3'0" | 86" | RH | HL | 9-1/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Storage |
| 117 | 3'0" | 86" | LH | S | 9-1/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Electrical |
| 118A | 3'0" | 86" | RH | S | 4-3/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Shower |
| 118 | 3'0" | 86" | RH | S | 9-1/4"" | 1-3/4" | 2-3/4" | CVG Fir | NA | Mud Room |
| 120 | 3'0" | 86" | LH | S | 5-1/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Supplies |
| 121 | 3'0" | 86" | RH | FL | 5-1/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Break Room |
| 122 | 3'0" | 86" | RH | FL | 5-1/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Small Conference Room |
| 123A | 3'0" | 86" | RH | FL | 8-3/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Hearing Room |
| 123B | 3'0" | 86" | LH | FL | 12-3/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Hearing Room |
| 124 | 3'0" | 86" | RH | HL | 8-3/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Office |
| 125 | 3'0" | 86" | RH | HL | 8-3/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Office |
| 126 | 3'0" | 86" | RH | HL | 8-3/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Office |
| 127 | 3'0" | 86" | LH | HL | 8-3/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Office |
| 129 | 3'0" | 86" | RH | HL | 8-3/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Office |
| 130 | 3'0" | 86" | RH | S | 4-3/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Server Room |
| Total Doors | 28 | |||||||||
| Full Lite FL | 6 | |||||||||
| Half Lite HL | 8 | |||||||||
| Solid | 14 |
| RH | LH | ||||
| Window # | Window Width | Window Height | Wall Thickness | # of Windows | Details |
| 100 | NA | Public Restroom | |||
| 102A | 2' | 5' | 8-3/4" | 1 | Plan Review Room |
| 102B | NA | Plan Review Room | |||
| 103 | 2' | 5' | 8-3/4" | 2 | Conference Room |
| 104 | 2' | 5' | 8-3/4" | 1 | Office Manager |
| 105 | NA | Directors Office | |||
| 106 | NA | Restroom | |||
| 107 | NA | Restroom | |||
| 108 | NA | Restroom | |||
| 109 | NA | Restroom | |||
| 110 | NA | Restroom | |||
| 111 | NA | Janitorial Closet | |||
| 112 | NA | Lactation Room | |||
| 113 | NA | Storage | |||
| 117 | NA | Electrical | |||
| 118A | NA | Shower | |||
| 118 | NA | Mud Room | |||
| 120 | NA | Supplies | |||
| 121 | NA | Break Room | |||
| 122 | 2' | 5' | 4-3/4" | 2 | Small Conference Room |
| 123A | Hearing Room | ||||
| 123B | 4' | 18" | 12-3/4" | 3 | Hearing Room |
| 124 | NA | Office | |||
| 125 | NA | Office | |||
| 126 | NA | Office | |||
| 127 | NA | Office | |||
| 129 | NA | Office | |||
| 130 | NA | Server Room |