Door_and_Window_Index_and_Meassurements_2.0.xlsx
XLSX spreadsheet 21 KB Posted
- Attached to
- 31-2102 Door Hardware
- Solicitation number
- 31-2102 Door Hardware
- Issued by
- Kittitas County, Washington
About this file
The document is a Door and Window Index spreadsheet for Lewis County's Community Development Building in Washington State, detailing comprehensive specifications for 28 interior doors and multiple windows. The inventory includes precise measurements for each door, with 3'0" width and 86" height, constructed of CVG Fir with varying wall thicknesses ranging from 4-3/4" to 12-3/4". The doors are categorized by room type, swing direction (Right Hand/Left Hand), and style (Full Lite, Half Lite, Solid), with specific hardware preparations including mortise installations for select rooms like public restrooms and the lactation room.
The project scope encompasses door hardware for various spaces including offices, conference rooms, restrooms, mechanical areas, and hearing rooms. Window specifications are partially documented, with some rooms having 2' x 5' windows and wall thicknesses noted. While pricing details are not included in this document, the comprehensive door and window index suggests a detailed procurement process for Lewis County's Community Development Building renovation or construction project. The spreadsheet provides critical technical specifications that would be essential for potential vendors bidding on the door hardware contract, offering precise measurements and room-specific requirements to ensure accurate product selection and installation.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 31-2102_Door_Hardware.pdf | ||
| J2037C__LCDP__Rainer_Bldg_A-floorplan.pdf | ||
| 31-2102_Door_Schedule.pdf | ||
| 31-2102_Project_Manual_Vol_1_.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Room | Door Size | Rough Height | Swing | FL/HL/S | Wall Thickness | Slab Thickness | Set Back Handlset | Finish | Door Hardware Prep | Details |
| 101AA | 3'0" | 86" | RH | S | 4-3/4" | 1-3/4" | 2-3/4" | CVG Fir | Mortise | Public Restroom |
| 102A | 3'0" | 86" | RH | S | 4-3/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Plan Review Room |
| 102B | 3'0" | 86" | LH | FL | 4-3/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Plan Review Room |
| 103 | 3'0 | 86" | RH | FL | 8-3/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Office Manager |
| 104 | 3'0" | 86" | RH | FL | 8-3/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Conference Room |
| 105 | 3'0" | 86" | RH | FL | 8-3/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Directors Office |
| 106 | 3'0" | 86" | LH | S | 6-3/4" | 1-3/4" | 2-3/4" | CVG Fir | Mortise | Restroom |
| 107 | 3'0" | 86" | LH | S | 6-3/4" | 1-3/4" | 2-3/4" | CVG Fir | Mortise | Restroom |
| 108 | 3'0" | 86" | LH | S | 6-3/4" | 1-3/4" | 2-3/4" | CVG Fir | Mortise | Restroom |
| 109 | 3'0" | 86" | LH | S | 6-3/4" | 1-3/4" | 2-3/4" | CVG Fir | Mortise | Restroom |
| 110 | 3'0" | 86" | LH | S | 6-3/4" | 1-3/4" | 2-3/4" | CVG Fir | Mortise | Restroom |
| 111 | 3'0" | 86" | LH | S | 4-3/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Custodial |
| 112 | 3'0" | 86" | LH | S | 4-3/4" | 1-3/4" | 2-3/4" | CVG Fir | Mortise | Lactation Room |
| 113 | 3'0" | 86" | RH | HL | 9-1/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Storage |
| 117 | 3'0" | 86" | LH | S | 9-1/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Mechanical |
| 118A | 3'0" | 86" | RH | S | 4-3/4" | 1-3/4" | 2-3/4" | CVG Fir | Mortise | Mudd Room |
| 118AA | 3'0" | 86" | RH | S | 9-1/4"" | 1-3/4" | 2-3/4" | CVG Fir | NA | Shower |
| 120 | 3'0" | 86" | LH | S | 5-1/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Supplies |
| 121 | 3'0" | 86" | LH | FL | 5-1/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Break Room |
| 122 | 3'0" | 86" | LH | FL | 5-1/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Small Conference Room |
| 123A | 3'0" | 86" | LH | FL | 8-3/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Hearing Room |
| 123B | 3'0" | 86" | LH | FL | 12-3/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Hearing Room |
| 124 | 3'0" | 86" | RH | HL | 8-3/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Office |
| 125 | 3'0" | 86" | LH | HL | 8-3/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Office |
| 126 | 3'0" | 86" | RH | HL | 8-3/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Office |
| 127 | 3'0" | 86" | LH | HL | 8-3/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Office |
| 129 | 3'0" | 86" | RH | HL | 8-3/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Office |
| 130 | 3'0" | 86" | LH | S | 4-3/4" | 1-3/4" | 2-3/4" | CVG Fir | NA | Server Room |
| Total Doors | 28 | |||||||||
| Full Lite FL | 8 | |||||||||
| Half Lite HL | 6 | |||||||||
| Solid | 14 |
| RH | LH | ||||
| Window # | Window Width | Window Height | Wall Thickness | # of Windows | Details |
| 100 | NA | Public Restroom | |||
| 102A | 2' | 5' | 8-3/4" | 1 | Plan Review Room |
| 102B | NA | Plan Review Room | |||
| 103 | 2' | 5' | 8-3/4" | 2 | Conference Room |
| 104 | 2' | 5' | 8-3/4" | 1 | Office Manager |
| 105 | NA | Directors Office | |||
| 106 | NA | Restroom | |||
| 107 | NA | Restroom | |||
| 108 | NA | Restroom | |||
| 109 | NA | Restroom | |||
| 110 | NA | Restroom | |||
| 111 | NA | Janitorial Closet | |||
| 112 | NA | Lactation Room | |||
| 113 | NA | Storage | |||
| 117 | NA | Electrical | |||
| 118A | NA | Shower | |||
| 118 | NA | Mud Room | |||
| 120 | NA | Supplies | |||
| 121 | NA | Break Room | |||
| 122 | 2' | 5' | 4-3/4" | 2 | Small Conference Room |
| 123A | Hearing Room | ||||
| 123B | 4' | 18" | 12-3/4" | 3 | Hearing Room |
| 124 | NA | Office | |||
| 125 | NA | Office | |||
| 126 | NA | Office | |||
| 127 | NA | Office | |||
| 129 | NA | Office | |||
| 130 | NA | Server Room |
File details come from the government source that posted it. Updated .