Facility_Survey_(Volume_2).pdf
PDF 21 MB Posted
- Attached to
- Operation of the Tongue Point Job Corps Center
- Solicitation number
- DOLJ14SA00006
About this file
Facility Survey (Volume 2)
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment_5.pdf | ||
| Amendment_4.pdf | ||
| Revised_National_Staff_Compensation_Table.pdf | ||
| Amendment_3.pdf | ||
| Amendment_2.pdf | ||
| Amendment_1.pdf | ||
| Site_Map.pdf | ||
| Utilities_and_Fuel_Usage.pdf | ||
| National_Staff_Compensation_Table.pdf | ||
| Inventory_Estimate.pdf | ||
| MOU_with_Clatsop_Community_College.pdf | ||
| Regional_Career_Pathways_Plan.pdf | ||
| Space_Utilization.pdf | ||
| Facility_Survey_(Volume_1).pdf | ||
| Solicitation.docx | DOCX document |
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Tongue Point
Job Corps Center Astoria, OR
Facility Planning Report Volume II
Supporting Data
Final June 2013
Department of Labor/ Office of Job Corps
22Tongue Point Job Corps Center
Tongue Point
Job Corps Center Astoria, OR
Facility Planning Report Volume II
Supporting Data
Final June 2013
Residence 3 Building 21
33 Tongue Point Job Corps Center
CONTENTS
TONGUE POINT JOB CORPS CENTER
FACILITY PLANNING REPORT
VOLUME I - Planning Strategy
• Existing Site Plan
• Center Statistics
INTRODUCTION
• Purpose
• Report Contents
EXECUTIVE SUMMARY
A. EXISTING CONDITIONS
• Background
• General Site Conditions
• General Building Conditions
• Preventive Maintenance
• Ownership
• Facility Assessment by Function
• Energy Issues
• Environmental Issues
• Sustainability
• Accessibility Standards
• Health and Life Safety Issues
• Summary of Defi ciencies
B. RECOMMENDATIONS
• Status of the Previous (PY09) Plan
• Signifi cant Issues
• PY 12 Plan Overview
• Summary of Proposed Projects
• Proposed Site Plan
• Implementation Plan
• Summary of National Projects
• Project Data Sheets
C. PLANNING ANALYSIS
• Purpose
• Planning Objectives and Assumptions
• Space Utilization Analysis
• Federal Real Property Asset Management
• Mission Dependency Site Plan
• Defi ciency Analysis
• Facility Condition Summary Report
• Building Condition by Function
• Building Condition Site Plan
VOLUME II - Supporting Data
• Vicinity Map
• Location Map
• Existing Site Plan
D. DESCRIPTIONS
• Buildings and Structures
• Space Utilization By Function
• NSF by Building
• Energy Management Report
• Environmental Management
Asbestos Report Radon Report
• Site Descriptions
• Building Descriptions
E. DEFICIENCIES
F. CORRESPONDENCE AND REPORTS
• Center Review Meeting Minutes
• Survey Brief
• RA and Student Facility Feedback Questionnaire
• Life Safety Defi ciencies Transmittal and List
• O & M Defi ciency List
• Active Warranty Report
• FRPC Performance Measures Matrix
44Tongue Point Job Corps Center
55 Tongue Point Job Corps Center
66Tongue Point Job Corps Center
77 Tongue Point Job Corps Center
D Descriptions
BUILDINGS AND STRUCTURES
01002 TONGUE POINT 06/18/2013
1Page: of Date:
0001 - RECREATION/EDUCATION
0002 - CAFETERIA/CULINARY ARTS
0003 - ACADEMIC
0005 - BUILDING TRADES VOCATION
0006 - CENTER OPERATIONS/SOFT VOC
0007 - RESIDENCE 1 & 2/CTS
0008 - ADMINISTRATION
0009 - CAREER PREPARATION
0010 - CAREER PREPARATION
0011 - CAREER PREPARATION
0012 - CAREER PREPARATION
0018 - OLD THEATER
0019 - MEDICAL/DENTAL
0021 - RESIDENCE 3
0022 - PROPERTY & LOGISTICS
0030 - VOCATIONS/MOTOR POOL
0045 - STORAGE
0048 - MAINTENANCE STORAGE
0052 - COUNSELING
0059 - VOCATIONAL STORAGE
0074A - CTST WAREHOUSE
0100 - RESIDENCE 4
0101 - RESIDENCE 4 LOUNGE
0102 - GREENHOUSE
0103 - SEAMANSHIP VOCATION
0104 - LANDSCAPING CLASSROOM
0106 - ADVANCED CAREER TRAINING
0130 - SECURITY
0131 - GATEHOUSE
0133 - VISITOR CENTER
0163 - LANDSCAPE STORAGE
0170 - SPRAY PAINT BOOTH
0005A - BOILER STRUCTURE
0006A - CLEANING STORAGE
0008A - SHELTER
0017 - FLAMMABLE STORAGE
0021A - GENERATOR SHED
0023 - STORAGE
0024 - PAVILION
0030A - WATER METER SHED
0052A - SHELTER
0058 - STORAGE
0105 - LATH HOUSE
0107 - POTTING SHED
0126 - VEHICLE STORAGE SHED
0130A - GENERATOR BUILDING
0132 - STORAGE
0133A - PAVILION
0164 - SAND BLAST BOOTH
0168 - POWER DISTRIBUTION SHED
Name GSF
52,565 15,977 17,848 32,501 27,057
109,925 14,226 1,344 1,400 1,720 1,720
12,165 11,033 33,031 5,912
20,140 2,130 1,560 3,770
3,042 9,850 2,288
3,410
2,685 1,320
1,200
2,880
8,200
Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active
StatusType
Building Building Building Building Building Building Building Building Building Building Building Building Building Building Building Building Building Building Building Building Building Building Building Building Building Building Building Building Building Building Building Building Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure
Use Group Built Flrs Const
Assembly Assembly Business Business Business Residential Business Business Business Business Business Storage Business Residential Storage Factory/Ind.
Storage Storage Business Storage Storage Residential Assembly Business Business Business Business Business Business Business Storage Factory/Ind.
Utility/Misc.
Assembly Storage Utility/Misc.
Storage Assembly Utility/Misc.
Assembly Storage Storage Storage Utility/Misc.
Utility/Misc.
Storage Utility/Misc.
Utility/Misc.
Utility/Misc.
Good Good Good Good Good Fair
Good Good Good Good Good Fair Fair Fair
Good Fair Poor Poor Good Good Good Good Good Good Good Good Good Good Good Good Good Good Fair Fair Fair Fair
Good Good Good Good Good Fair Fair
Good Fair
Good Good Good Good Good
ConditionAsset Number
0100200002 0100208168 0100200003 0100200005 0100200006 0100200007 0100200008 0100200046 0100200047 0100208144 0100208145 0100200010 0100200011 0100200012 0100200013 0100200015 0100200016 0100200017 0100200019 0100200021 0100200038 0100200023 0100200024 0100200025 0100200026 0100200027 0100200029 0100200031 0100200040 0100208169 0100200032 0100208146 0100208172 0100208170 0100208147 0100200035 0100208141 0100200014 0100200036 0100208150 0100208148 0100200020 0100200028 0100200037 0100200030 0100208173 0100200041 0100208181 0100200042 0100208142
BUILDINGS AND STRUCTURES
01002 TONGUE POINT 06/18/2013
2Page: of Date:
0169 - SEAMANSHIP VOC STORAGE
0200 - WATER TANK
0201 - WATER TANK
0202 - DIVERSITY GARDEN SHED
0203 - WIND TURBINE ELECTRICAL
0203A - WIND TURBINE
0204 - BIKE STORAGE
0205 - CEMENT SHELTER
0206 - PAINTING SHELTER
0207 - RADIO REPEATER EQUIPMENT
0208 - MASONRY WASH-OFF
0209 - EMERGENCY WATER STORAGE
TANK
0210 - SHED
SH-A - STAFF HOUSING
SH-B - STAFF HOUSING
SH-C - STAFF HOUSING
SH-D - STAFF HOUSING
SH-E - STAFF HOUSING
SH-F - STAFF HOUSING
SH-I - STAFF HOUSING
SH-J - STAFF HOUSING
SH-K - STAFF HOUSING
SH-L - STAFF HOUSING
SH-M - STAFF HOUSING
SH-N - STAFF HOUSING
SH-O - STAFF HOUSING
SH-P - STAFF HOUSING
SH-Q - STAFF HOUSING
Name GSF
1,963 1,963
4,203 3,786 3,786 3,786 3,786 3,786 1,118 1,118 1,118 1,118 1,118 1,118 1,118 1,118 2,280
Active Active Active Active Active Active Active Active Active Active Active Active
Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active
StatusType
Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure Structure
Structure Staff Hous Staff Hous Staff Hous Staff Hous Staff Hous Staff Hous Staff Hous Staff Hous Staff Hous Staff Hous Staff Hous Staff Hous Staff Hous Staff Hous Staff Hous
Use Group Built Flrs Const
Storage Utility/Misc.
Utility/Misc.
Storage Utility/Misc.
Utility/Misc.
Storage Utility/Misc.
Utility/Misc.
Utility/Misc.
Utility/Misc.
Utility/Misc.
Utility/Misc.
Residential Residential Residential Residential Residential Residential Residential Residential Residential Residential Residential Residential Residential Residential Residential
Good Poor Poor Good Good Good Good Good Good Good Good Good
Good
ConditionAsset Number
0100208143 0100208151 0100208152 0100208174 0100208175 0100208176 0100208177 0100208178 0100208179 0100208180 0100208182 0100208183
0100208184 0100208153 0100208154 0100208155 0100208156 0100208157 0100208158 0100208159 0100208160 0100208161 0100208162 0100208163 0100208164 0100208165 0100208166 0100208167
32 394,161
31 20,395
63 414,556
Buildings
Structures
Total
GSF
GSF
GSF
Summary (excludes staff housing)
Staff Housing Summary
Buildings
Structures
34,357
15 Total 34,357
GSF
GSF
GSF
06/18/2013
Space Utilization By Function 01002 Tongue Point Page: 1 of Date:
HOUSING
EDUCATION
FOOD SERVICE
SUGGESTED
NSF/
ENROLLEE
SUGGESTED
TOTAL
NSF
ACTUAL
TOTAL
NSF
TYPE OF SPACE
SUB TOTAL
SUB TOTAL
SUB TOTAL
Resident Men Resident Women Total Residents
Residents 525 Non Residents 0
525Total Students
(525)
(540)
(525)
DIFFERENCE
52,500
49,460
9,450
84,604
94,563
12,247
Lounge Other Shower/Toilet Sleeping excl. SPD( rooms; beds) Storage
Academic (540) Non-Academic
26 -- ACT (Off-Ctr) 90 -- Business Office Technologies 40 -- Carpentry + 20 -- Cement Masonry + 30 -- Computer Service Tech.
24 -- Electrical + 24 -- Facilities Maint. and Const. + 20 -- Food Service + 20 -- Glazing + 120 -- Health Occupations + 24 -- Landscaping + 20 -- Painting + 20 -- Plastering + 120 -- Seaman + 24 -- Welding +
Vocational Theory (476)
Dining (2 Servings) Food Preparation Food Storage
15,470 8,303
10,509 43,820
6,502
8,250 15,818
3,860 6,130 5,210
2,490 6,510 2,743 5,936 7,815 2,779 6,350 4,770 4,658 4,220
6,044
5,592 4,358 2,297
5,250
6,300 37,800
3,150
5,400 5,400
3,600 3,000 1,500
1,200 1,800 1,200
4,800 1,200 1,500 1,500 9,000 1,800
4,760
4,200 3,150 2,100
10,220
4,209 6,020 3,352
2,850 10,418
3,130 3,710
1,290 4,710 1,543 5,036 3,015 1,579 4,850 3,270 -4,342 2,420
1,284
1,392 1,208
Vocations
32,104
45,103
2,797
Page: 2 of Date:
RECREATION
MEDICAL/DENTAL
ADMINISTRATION
STORAGE/SUPPORT
VACANT
SUGGESTED
NSF/
ENROLLEE
SUGGESTED
TOTAL
NSF
ACTUAL
TOTAL
NSF
TYPE OF SPACE
SUB TOTAL
SUB TOTAL
SUB TOTAL
SUB TOTAL
SUB TOTAL
TOTAL 308.2 161,805 303,919
(525)
(525)
(525)
(525)
(0)
DIFFERENCE
26,250
3,145
10,500
29,603
8,375
17,002
31,010
26,515
Activity Room Arts & Crafts Gymnasium Miscellaneous Recreation Music Hall Pool Hall Raquetball Recreation Office Recreation Room Recreation Storage Roller Skating Rink Snack Bar Student Store Theater Weight Room
Medical/Dental
Administration
Operations & Maintenance Warehouse
Vacant
5.99
1,400 7,300 1,050
1,800 3,070 1,300
2,370 4,750
1,200 1,460 1,780
8,375
17,002
16,760 14,250
26,515
3,145
4,200 6,300
5,230
6,502
12,560 7,950
RESIDENT
NON-RESIDENT
(525)
(0) 15
50 26,250
3,353
5,230
6,502
20,510
26,515
142,114
Page: 3 of Date:
SUGGESTED
NSF/
ENROLLEE
SUGGESTED
TOTAL
NSF
ACTUAL
TOTAL
NSF
TYPE OF SPACE DIFFERENCE
394,161
0.77
TOTAL GSF
NET TO GROSS RATIO
Net Square Footage By Building Date: 06/18/2013 Page: 1
Center: TONGUE POINT (01002) of 5
HOUSING
Sleeping excl. SPD
Lounge
Storage
Shower/Toilet
Other
Function Suggested
NSF
5,840 9,560
28,420
1,230 6,810 7,430
2,710
3,184
6,100 2,269 2,140
3,680
2,570 1,014
0100 - RESIDENCE 4
0021 - RESIDENCE 3
0007 - RESIDENCE 1 & 2/CTS
0101 - RESIDENCE 4 LOUNGE
0021 - RESIDENCE 3
0007 - RESIDENCE 1 & 2/CTS
0007 - RESIDENCE 1 & 2/CTS
0100 - RESIDENCE 4
0021 - RESIDENCE 3
0007 - RESIDENCE 1 & 2/CTS
0021 - RESIDENCE 3
0100 - RESIDENCE 4
0100 - RESIDENCE 4
0007 - RESIDENCE 1 & 2/CTS
0101 - RESIDENCE 4 LOUNGE
0021 - RESIDENCE 3
0001 - RECREATION/EDUCATION
Bldg Name Actual NSF Difference
43,820
15,470
6,502
10,509
8,303
Sub Total: 84,604
37,800
5,250
3,150
6,300
52,500
6,020
10,220
3,352
4,209
8,303
( 525
32,104 rooms; beds rooms; beds rooms; beds
Page: 2
Center: TONGUE POINT (01002) of 5
EDUCATION
Academic
Vocational Theory (476)
Carpentry
Cement Masonry
Electrical
Health Occupations
Welding
Painting
Plastering
Computer Service Tech.
Facilities Maint. and Const.
Function Suggested
NSF
1,175 2,760
1,130 1,590
1,980
2,064
5,200
5,210
2,490
7,040
4,220
1,100 5,250
3,840
3,640 2,870
0003 - ACADEMIC
0003 - ACADEMIC
0003 - ACADEMIC
0003 - ACADEMIC
0003 - ACADEMIC
0003 - ACADEMIC
0003 - ACADEMIC
0030 - VOCATIONS/MOTOR POOL
0103 - SEAMANSHIP VOCATION
0001 - RECREATION/EDUCATION
0007 - RESIDENCE 1 & 2/CTS
0005 - BUILDING TRADES VOCATION
0005 - BUILDING TRADES VOCATION
0001 - RECREATION/EDUCATION
0005 - BUILDING TRADES VOCATION
0030 - VOCATIONS/MOTOR POOL
0006 - CENTER OPERATIONS/SOFT VOC
0019 - MEDICAL/DENTAL
0030 - VOCATIONS/MOTOR POOL
0170 - SPRAY PAINT BOOTH
0005 - BUILDING TRADES VOCATION
0001 - RECREATION/EDUCATION
0005 - BUILDING TRADES VOCATION
0001 - RECREATION/EDUCATION
0030 - VOCATIONS/MOTOR POOL
0074A - CTST WAREHOUSE
Bldg Name Actual NSF Difference
8,250
6,044
6,130
5,210
2,490
7,815
4,220
6,350
4,770
6,510
5,400
4,760
3,000
1,500
1,200
4,800
1,800
1,500
1,500
1,800
2,850
1,284
3,130
3,710
1,290
3,015
2,420
4,850
3,270
4,710
( 540 )
Page: 3
Center: TONGUE POINT (01002) of 5
EDUCATION
FOOD SERVICE
Landscaping
Food Service
Non-Academic
Business Office Technologies
Glazing
Seaman
Dining (2 Servings)
Food Preparation
Food Storage
Function Suggested
NSF
2,743
1,922 1,508 1,508
2,710 1,200 3,300 2,170
3,860
5,006
2,138 2,520
5,262
4,028
1,302
0059 - VOCATIONAL STORAGE
0163 - LANDSCAPE STORAGE
0104 - LANDSCAPING CLASSROOM
0102 - GREENHOUSE
0002 - CAFETERIA/CULINARY ARTS
0106 - ADVANCED CAREER TRAINING
0012 - CAREER PREPARATION
0011 - CAREER PREPARATION
0009 - CAREER PREPARATION
0003 - ACADEMIC
0007 - RESIDENCE 1 & 2/CTS
0010 - CAREER PREPARATION
0052 - COUNSELING
0003 - ACADEMIC
0001 - RECREATION/EDUCATION
0001 - RECREATION/EDUCATION
0005 - BUILDING TRADES VOCATION
0103 - SEAMANSHIP VOCATION
0007 - RESIDENCE 1 & 2/CTS
0021 - RESIDENCE 3
0002 - CAFETERIA/CULINARY ARTS
0021 - RESIDENCE 3
0002 - CAFETERIA/CULINARY ARTS
0022 - PROPERTY & LOGISTICS
0021 - RESIDENCE 3
0002 - CAFETERIA/CULINARY ARTS
Bldg Name Actual NSF Difference
2,779
2,743
15,818
3,860
5,936
4,658
5,592
4,358
2,297
Sub Total:
Sub Total:
94,563
12,247
1,200
1,200
5,400
3,600
9,000
4,200
3,150
2,100
49,460
9,450
1,579
1,543
10,418
5,036
-4,342
1,392
1,208
( 525
45,103
2,797
Page: 4
Center: TONGUE POINT (01002) of 5
RECREATION
MEDICAL/DENTAL
Snack Bar
Arts & Crafts
Gymnasium
Weight Room
Theater
Raquetball
Student Store
Miscellaneous Recreation
Pool Hall
Music Hall
Roller Skating Rink
Activity Room
Recreation Room
Recreation Storage
Recreation Office
Medical/Dental
Function Suggested
NSF
1,400
7,300
1,780
1,460
3,070
1,200
1,050
1,800
4,750
2,370
1,300
7,410
0106 - ADVANCED CAREER TRAINING
0001 - RECREATION/EDUCATION
0001 - RECREATION/EDUCATION
0001 - RECREATION/EDUCATION
0001 - RECREATION/EDUCATION
0001 - RECREATION/EDUCATION
0001 - RECREATION/EDUCATION
0007 - RESIDENCE 1 & 2/CTS
0001 - RECREATION/EDUCATION
0001 - RECREATION/EDUCATION
0001 - RECREATION/EDUCATION
0001 - RECREATION/EDUCATION
0001 - RECREATION/EDUCATION
0001 - RECREATION/EDUCATION
0001 - RECREATION/EDUCATION
0019 - MEDICAL/DENTAL
0007 - RESIDENCE 1 & 2/CTS
Bldg Name Actual NSF Difference
1,400
7,300
1,780
1,460
3,070
1,200
1,050
1,800
4,750
2,370
1,300
8,375
Sub Total:
Sub Total:
29,603
8,375
3,145
26,250
3,145
5,230
3,353
5,230
Page: 5
Center: TONGUE POINT (01002) of 5
ADMINISTRATION
STORAGE/SUPPORT
VACANT
Administration
Warehouse
Operations & Maintenance
Vacant
Function Suggested
NSF
3,100 1,010
9,894
1,080
4,240 7,750 2,260
4,320 10,960
1,480
12,630 2,460 2,290 2,080
1,650 1,480 3,710
0133 - VISITOR CENTER
0007 - RESIDENCE 1 & 2/CTS
0006 - CENTER OPERATIONS/SOFT VOC
0131 - GATEHOUSE
0106 - ADVANCED CAREER TRAINING
0022 - PROPERTY & LOGISTICS
0008 - ADMINISTRATION
0003 - ACADEMIC
0130 - SECURITY
0022 - PROPERTY & LOGISTICS
0018 - OLD THEATER
0006 - CENTER OPERATIONS/SOFT VOC
0030 - VOCATIONS/MOTOR POOL
0006 - CENTER OPERATIONS/SOFT VOC
0048 - MAINTENANCE STORAGE
0007 - RESIDENCE 1 & 2/CTS
0001 - RECREATION/EDUCATION
0018 - OLD THEATER
0045 - STORAGE
0103 - SEAMANSHIP VOCATION
0030 - VOCATIONS/MOTOR POOL
0006 - CENTER OPERATIONS/SOFT VOC
0003 - ACADEMIC
Bldg Name Actual NSF Difference
17,002
14,250
16,760
26,515
Sub Total:
Sub Total:
Sub Total:
17,002
31,010
26,515
10,500
6,300
4,200
10,500
10,500
6,502
7,950
12,560
26,515
6,502
20,510
26,515
Energy Management Report Center: TONGUE POINT (01002)
Page: 1 Date: 06/18/2013 of 3
CENTER ENERGY DATA
Yes
ENERGY CONSUMPTION ASSESSMENT
1% 84,534
67,461 85,394
ENERGY USE BY FUEL TYPE
Energy Audit :
Date of Audit :
Status of Energy Conservation Measure Recommendations :
Electric Company :
Percent Change since Baseline Year :
Natural Gas Company :
Property Status :
12/1/1999 Not Implemented Pacific Power & Light Northwest Natural Gas Company
Federally Owned (DOL)
3,120,405 10,647=
Total 36,224
MBtu
MBtu
Total $404,497 MBtu/ $11.167
BTU/GSF
BTU/GSF
BTU/GSF
Electricity
Natural Gas kWh
24,808 MCF = 25,577 MBtu
$224,041 $0.072= kWhElectricity
Natural Gas $180,456 = $7.274 MCF
ENERGY COST BY FUEL TYPE
COMMENTS
8/1/01 Building renovations include T8s, Installing Shower heads, WATER CONSUMPTION ASSESSMENT
Percent Reduction Compared to Goal:
1,000 Gallons
1,000 Gallons
FY 2012 Energy Goal:
Further Reduction in Energy Usage is needed to meet Energy Reduction Goals.
FY 2012 Energy Consumption:
Note: The Federal Government has set a goal of 3% Energy Consumption reduction per year in EO 13423.
15,120 13,608 13,462
+ 1%
Water Goals are being met. Keep reducing Water Consumption.
Note:
FY 2012 Goal:
FY 2012 Water Consumption:
1,000 Gallons
FY 2003 Energy Baseline:
FY 2007 Baseline:
The Federal Government has set a goal of 2% Water Consumption reduction per year in EO 13423 compared to the FY 2007 Baseline.
Page: 2 of 3
Implementing some of the below recommendations can save you 10% to 25% off your annual energy bill without negatively impacting comfort or productivity.
1. Your staff and students are the key to savings. Educate the students and staff on the why of energy saving - costs and environmental impacts. Encouraging them to actively participate in energy reduction is also important. Post reminders at exit doors and bulletin boards about energy conservation. Simple tips include:
a. Turn it down (lights, heating & cooling),
b. Turn it off (lights, computers, other equipment),
c. Keep it tight (close doors and windows, use window blinds)
2. Operations and Maintenance: Educate the O&M staff on the why of energy saving -costs and environmental impacts. Simple tips include:
a. Make sure that the Operations and Maintenance staff is properly trained for the equipment they operate.
b. Tune and clean HVAC: Perform seasonal cleanups on air conditioners, boilers and furnaces, and regularly clean cooling coils and drain pans. Get rooftop or outdoor condenser coils cleaned and maintain an appropriate filter changing schedule.
c. Check (or ask your HVAC contractor to check) your outside air dampers or economizers to verify proper ventilation. Make sure economizer controls function properly. Make sure automatic dampers close during unoccupied periods.
d. Restore automatic control: When troubleshooting a system, take time to figure out and repair the automatic controls. Today's quick fix is tomorrow's bad idea.
e. Reasonable set points: Try 68°F in the heating season and 75°F in the cooling season.
f. Schedule HVAC equipment and lighting: (weekdays, weekends, holidays, off-season). Make sure equipment runs only when it is needed and the buildings are occupied. When buildings are vacant (i.e. dormitories during the day with students in class), make sure all the lights in the building are off.
g. Seasonal (resets, schedules, and shutoffs): As the seasons change, adjust set points and schedules to match the system's response to the weather.
h. Lighting: Invest in an inexpensive light level meter to measure the foot-candles in spaces to determine whether or not they are over lit and lamps can be safely removed. Where four-lamp fixtures are in use, two lamps can usually be removed from every fixture or every other fixture. After lamps are removed, disconnect ballasts. Contact the Energy team at PBDewberry for suggested light levels for individual space types. Cleaning fixtures regularly increases light levels.
i. Utilize power management features for all computers and monitors to shut them off when idle for more than 15 minutes.
Page: 3 of 3
j. Have your vending machine suppliers turn off or remove light tubes from the advertising lighting in the machine. This will save about $50 per year per vending machine.
k. Save water with low flow sink aerators (0.5gpm) and low flow shower heads (1.5gpm - 2.0gpm). This will also reduce water heating energy consumption.
l. Set your water heater to 120°F. Verify by measuring at the tap. Never go below 115°F.
m. For water heaters installed in unconditioned spaces, add insulation blankets making sure that access covers, electric connection areas, and pressure relief valves are left uncovered.
n. Caulk and fill cracks around doors and windows to reduce costly air leaks.
o. When replacing broken glass, use high transmittance, low heat gain windows.
p. Make sure automatic door closers are functioning properly to avoid drafts.
3. Buy energy efficient, buy EnergyStar (www.energystar.gov).
a. Buy EnergyStar appliances and equipment.
b. Replace burned out lightbulbs with EnergyStar labeled compact fluorescent lightbulbs (CFLs).
c. Replace broken thermostats with EnergyStar labeled programmable products.
d. Replace broken exit signs with EnergyStar LED exit signs.
Environmental Management Report
Page: 1 Date: 06/18/2013 of 1
SOLID & HAZARDOUS WASTE MANAGEMENT (RCRA)
Commercial Waste Service
HAZARDOUS MATERIALS STORAGE (EPCRA)
Yes Buildings 17 and 102
Oil based paint (20 gals), propane fuel (100 gals) Yes
PETROLEUM UNDERGROUND STORAGE TANKS (RCRA)
N/A0
PETROLEUM ABOVEGROUND STORAGE TANKS (CWA)
ASBESTOS AND PCB MANAGEMENT (TSCA)
AIR POLLUTION CONTROL (CAA)
N/A None
Attainment
Solid Waste Disposal :
Hazardous Waste Generator :
Hazardous Waste ID :
Generator Classification :
Hazadous Materials Storage :
Hazardous Materials ID :
HazMat Storage Area :
HazMat Spill Response Plan :
Number of Regulated USTs :
Number of Un-regulated USTs :
Local Hazardous Use Permit :
LEPC Notification :
EPA Generator ID Number :
Hazardous Waste Disposal :
RCRA Compliance
ID LocationFuel Type Capacity
Number of ASTs :
Asbestos Survey Date :
Asbestos Type :
Asbestos Coordinator :
Coordinator Training Date:
Custodial/Maintenance Training :
AHERA Regulated :
Management Plan Approval :
PCB Transformer Testing :
PCB Transformers :
PCB-Contaminated Transformers :
Transformers Labelled :
Regional Air Quality :
Permitted Air Pollution Source :
Source Description :
Sunset Refuse and Recycling Yes Oil based paint (5 gals/month), organic solvent (10 gals/month)
Conditionally Exempt Small Quantity Generator
OR2161630643
Commercial Hazardous Waste Disposal Service
Safety Kleen
No Yes
Overfill Leak Corrosion
SPCC Plan Required : SPCC Plan Completed :
Yes Yes
10/24/1990 Friable/Non-Friable Blake Denhart
Yes No N/A Yes Yes
ID Fuel Type Capacity Location Overfill
Prevention Secondary Containment
Petroleum - Diesel Fuel
Petroleum - Waste Oil
Petroleum - Gasoline
Building 30
Building 30
Building 30
Yes
Yes
Yes
Yes
Yes
Yes
Tank Status Active
Active
Active
Tank Status Prevention/Detection
Asbestos-Containing Materials Inventory
Date: 06/19/2013Center : Tongue Point (01002) Page: 1 of 3
Heating Bldg Sewer, Water, Storm Dra Floor Finishes
Floor Finishes Floor Finishes
Floor Finishes Floor Finishes Heating
Ceiling Finishes Floor Finishes Heating Floor Finishes Floor Finishes Floor Finishes
Floor Finishes Floor Finishes Heating Floor Finishes Heating
Bldg System
Bldg System
Bldg System
Bldg System
Bldg System
Pipe insulation Pipe insulation 9x9 floor tile
12x12 floor tile 9x9 floor tile
Mastic beneath 12x12 tile 9x9 floor tile Pipe insulation
Asbestos cement board Mastic beneath 12x12 tile Pipe insulation 9x9 floor tile 12x12 floor tile, red 12x12 floor tile
9x9 floor tile 12x12 floor tile Tank insulation Linoleum Pipe insulation
Category Description
Category Description
Category Description
Category Description
Category Description
Lin. Ft.
Lin. Ft.
Sq. Ft.
Sq. Ft.
Sq. Ft.
Sq. Ft.
Sq. Ft.
Lin. Ft.
Sq. Ft.
Sq. Ft.
Lin. Ft.
Sq. Ft.
Sq. Ft.
Sq. Ft.
Sq. Ft.
Sq. Ft.
Sq. Ft.
Sq. Ft.
Lin. Ft.
Location
Location
Location
Location
Location
Unit
Unit
Unit
Unit
Unit
Quantity
Quantity
Quantity
Quantity
Quantity
Throughout 2nd floor classroom Throughout
Throughout Throughout
Paint shop storage Throughout Throughout
Throughout 2nd floor hallway Throughout Throughout Admin/storage Firehouse area
Throughout Throughout Mechanical room Ground floor, N wing Throughout
10000
35000 35000
Building :
Building :
Building :
Building :
Building :
0001 - RECREATION/EDUCATION
0003 - ACADEMIC
0005 - BUILDING TRADES VOCATION
0006 - CENTER OPERATIONS/SOFT VOC
0007 - RESIDENCE 1 & 2/CTS
Page: 2 of 3
Ceiling Finishes Floor Finishes Floor Finishes Heating
Roof Repair/Replacement Wall Finishes Heating
Wall Finishes Floor Finishes Heating Floor Finishes
Ceiling Finishes Floor Finishes Heating
Heating
Roof Repair/Replacement Floor Finishes Heating
Bldg System
Bldg System
Bldg System
Bldg System
Bldg System
Bldg System
Acoustical plaster 9x9 floor tile 12x12 floor tile Pipe insulation
Roof membrane Acoustical panels Pipe insulation
Asbestos cement board 12x12 floor tiles Pipe insulation 9x9 floor tiles
Acoustical plaster 9x9 floor tile Pipe insulation
Pipe insulation
Roof membrane 9x9 floor tile, brown Pipe insulation
Category Description
Category Description
Category Description
Category Description
Category Description
Category Description
Sq. Ft.
Sq. Ft.
Sq. Ft.
Lin. Ft.
Sq. Ft.
Sq. Ft.
Lin. Ft.
Sq. Ft.
Sq. Ft.
Lin. Ft.
Sq. Ft.
Sq. Ft.
Sq. Ft.
Lin. Ft.
Lin. Ft.
Sq. Ft.
Sq. Ft.
Lin. Ft.
Location
Location
Location
Location
Location
Location
Unit
Unit
Unit
Unit
Unit
Unit
Quantity
Quantity
Quantity
Quantity
Quantity
Quantity
Throughout Throughout Throughout Throughout
Throughout Projector room Rear storage area
Bathroom showers Throughout Throughout Throughout
Throughout Throughout Throughout
Service counter
Throughout Office Throughout
10000 17500
Building :
Building :
Building :
Building :
Building :
Building :
0008 - ADMINISTRATION
0018 - OLD THEATER
0019 - MEDICAL/DENTAL
0021 - RESIDENCE 3
0022 - PROPERTY & LOGISTICS
0030 - VOCATIONS/MOTOR POOL
Page: 3 of 3
Wall Finishes
Roof Repair/Replacement Heating
Floor Finishes
Floor Finishes Floor Finishes
Floor Finishes Heating
Bldg System
Bldg System
Bldg System
Bldg System
Bldg System
Asbestos cement board
Roof membrane Pipe insulation
Linoleum
Mastic beneath 12x12 tile Linoleum
9x9 floor tile Pipe insulation
Category Description
Category Description
Category Description
Category Description
Category Description
Sq. Ft.
Sq. Ft.
Lin. Ft.
Sq. Ft.
Sq. Ft.
Sq. Ft.
Sq. Ft.
Lin. Ft.
Location
Location
Location
Location
Location
Unit
Unit
Unit
Unit
Unit
Quantity
Quantity
Quantity
Quantity
Quantity
Wood shop
Lower roof Space heater
Throughout
Recreation area Kitchen/storage area
Throughout Throughout
Building :
Building :
Building :
Building :
Building :
0045 - STORAGE
0052 - COUNSELING
0100 - RESIDENCE 4
0106 - ADVANCED CAREER TRAINING
0130 - SECURITY
Radon
Date: 06/18/2013Center : Tongue Point (01002) Page: 1 of 2
0001 - RECREATION/EDUCATION
0002 - CAFETERIA/CULINARY ARTS
0003 - ACADEMIC
0005 - BUILDING TRADES VOCATION
0006 - CENTER OPERATIONS/SOFT VOC
0007 - RESIDENCE 1 & 2/CTS
0008 - ADMINISTRATION
0009 - CAREER PREPARATION
0010 - CAREER PREPARATION
0011 - CAREER PREPARATION
0012 - CAREER PREPARATION
0018 - OLD THEATER
0019 - MEDICAL/DENTAL
0021 - RESIDENCE 3
0022 - PROPERTY & LOGISTICS
0030 - VOCATIONS/MOTOR POOL
0045 - STORAGE
0048 - MAINTENANCE STORAGE
0052 - COUNSELING
0059 - VOCATIONAL STORAGE
0074A - CTST WAREHOUSE
0100 - RESIDENCE 4
0101 - RESIDENCE 4 LOUNGE
0102 - GREENHOUSE
0103 - SEAMANSHIP VOCATION
0104 - LANDSCAPING CLASSROOM
0106 - ADVANCED CAREER TRAINING
0130 - SECURITY
0131 - GATEHOUSE
0133 - VISITOR CENTER
0163 - LANDSCAPE STORAGE
0170 - SPRAY PAINT BOOTH
SH-A - STAFF HOUSING
SH-B - STAFF HOUSING
Bldg Name
08/11/1992
05/30/1990
05/30/1990
05/30/1990
05/30/1990
05/30/1990
05/30/1990
05/30/1990
08/11/1992
05/30/1990
05/30/1990
05/30/1990
05/30/1990
05/30/1990
05/30/1990
05/30/1990
05/30/1990
05/30/1990
05/30/1990
05/30/1990
05/30/1990
05/30/1990
10/24/1990
Test Date
Yes
No
Yes
Yes
Yes
Yes
Yes
N/A
N/A
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
N/A
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
Yes
No
No
No
Radon Testing
< 4 pCi
< 4 pCi
< 4 pCi
< 4 pCi
< 4 pCi
< 4 pCi
< 4 pCi
4 - 20 pCi
< 4 pCi
< 4 pCi
< 4 pCi
< 4 pCi
< 4 pCi
< 4 pCi
< 4 pCi
< 4 pCi
< 4 pCi
< 4 pCi
< 4 pCi
< 4 pCi
< 4 pCi
< 4 pCi
Test Result
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Yes
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Mitigation
01/01/2008
Mitigation Date
Radon
Page: 2 of 2
SH-C - STAFF HOUSING
SH-D - STAFF HOUSING
SH-E - STAFF HOUSING
SH-F - STAFF HOUSING
SH-I - STAFF HOUSING
SH-J - STAFF HOUSING
SH-K - STAFF HOUSING
SH-L - STAFF HOUSING
SH-M - STAFF HOUSING
SH-N - STAFF HOUSING
SH-O - STAFF HOUSING
SH-P - STAFF HOUSING
SH-Q - STAFF HOUSING
Bldg Name Test Date
No
No
No
No
No
No
No
No
No
No
No
No
No
Radon Testing
Test Result
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Mitigation Mitigation Date
RADON EXPLANATORY NOTES
The US Environmental Protection Agency (EPA) has established a radon action level of 4.0 picoCuries per liter (pCi/L). Occupied buildings with radon concentrations less than 4.0 pCi/L do not require radon mitigation; un-occupied buildings, or those buildings which are occupied only infrequently for brief periods of time, also do not require radon mitigation. Occupied buildings with radon concentrations greater than
4.0 pCi/L require radon mitigation and verification of radon reductions as soon as possible, with priority given to dormitories and student recreation buildings. Occupied buildings with radon concentrations greater than 20.0 pCi/L should be considered significant radon exposure hazards, and priority for mitigation should be given to buildings with these highly elevated radon concentrations.
Radon mitigation techniques include: (1) adjustment of the building HVAC system to create a positive pressure within the building; (2) sealing of foundation wall cracks, penetrations, or other openings;
(3) sealing crawlspace openings and sump pits; (4) installing an active subslab depressurization (ASD) system.
Site Description
TONGUE POINT
Aerial view of center
Page: 1 Date: 06/18/2013 of 4
Paving Type for Roads & Parking Paving Type for Sidewalks
Asphalt, Concrete Concrete
Comments:
Topography Buildings and Structures
Center is not fully enclosed by fencing. The chain link is located around the hillside of the property, along the south property line and separating the center from the Coast Guard station.
ROADS, PARKING & SIDEWALKS
Water Source Water Authority Service Meter On-Site Treatment Plant
1. Water System
Treatment Type Storage Type Storage Capacity(Gallons)
NoMasterCity of Astoria Utilities DepartmentPublic Water Authority
None 0None
Comments:
Fire Hydrants On-Site Water Supply Storage Capacity
(Gallons) Pressure Source FD Response Time (Minutes)
Yes 0 10None Municipal
The nearest fire station is the Astoria Fire Department.
Comments:
Sewage Treatment Flow
There is a single master meter for the entire site. There is gravity flow to four duplex lift stations.
Utility
Publicly Owned Treatment Works
Center
Gravity and Lift Stations
Maintenance ResponsibilityOwnership
Number of Deficiencies = 3
Number of Deficiencies = 1
SITE FEATURES
UTILITIES
Number of Deficiencies = 33. Sanitary Sewer System/ Sewage Treatment Plant
2. Fire Protection System
Buildings Structures47 31Terraced
Surrounding
Outdoor Recreation
Columbia River, Light Industrial, Rural
Baseball Field Concrete/Wood Docks, Photovoltaic Panel, Water Tanks
Exterior Storage
Storage Yard at Building 74A
Wood
Concrete
Location Type
Maintenance Responsibility System Capacity Adequate System Condition
Utility Center Yes Good
Separate Loop
No
Ownership Maintenance Responsibility System Capacity Adequate System Condition
Center Center Yes Fair
System Capacity Adequate System Condition
Yes Fair
Ownership
Roads & Parking Adequate Roads & Parking Condition Sidewalks Adequate Sidewalk Condition Yes Good Yes Good
Number of Deficiencies = 1
Fencing
Other Features
Page: 2 Date: 06/18/2013 of 4
Comments: There is a single master meter for the entire site.
Northwest Natural Gas Company
Comments:
Electric Company PCB Trans.
Transformer Mounting Transformer Ownership
Systems Ownership Maintenance Responsibility
Pacific Power & Light
The 12.47 kV primary overhead lines are brought to three utility-owned platform transformers outside Power Distribution Structure 168 on the center. The secondary 2.4 kV, 3-phase, 3 wire overhead service drop terminates in a metered switchgear located in this structure. Six underground feeders, radial from the switchgear, supply power to the entire center via center-owned, pad-mounted transformers located near the buildings served. Feeder #1 serves the central group of buildings which include Buildings 1, 3, 5 and 106. Feeder #2 serves Buildings 7 and 8 on the western campus and Feeder #7 serves the eastern group of buildings which includes Buildings 52, 59, 102, 103 and 104. Feeder #3 serves Buildings 9, 10, 11, 12, 21, 22, 100, 101 and Quarters A, B and C on the northern campus. The southern campus, consisting of Buildings 6, 18, 19, 30, 45, 48, 74A, 130, 131, 133 and Quarters I, J, K, L, M, N, O and P, is served from Feeder #4. Feeder #6 serves the street lights. In addition to the 120/208V system, the welding shop in Building 30 has a 480/277V system for the TIG welders. Most buildings are individually metered. There are three lift stations along side the railroad, each is supported by a 15 kW generator and manual transfer switch (MTS). A fourth lift station is supported by a 35 kW generator and an automatic transfer switch (ATS) located in Building 8 ground level. A 6 kW generator and MTS in Building 21 provide back-up power to fluorescent lights to enhance the emergency lighting system in the building. A mobile 36 kW generator and MTS provide back-up power to freezers, kitchen equipment and some lighting in Dining Hall Building 2. Security Building 130 and Gatehouse Building 131 are also supported by a 30 kW generator and MTS.
Pad and Platform Utility, Center
Utility, Center Utility, Center
No
12.47 kV and 2.4 kV, 3-Ph, 3 W
480/277V & 120/208V, 3-Ph, 4 WUnderground
OverheadPrimary Service
Secondary Service
Distribution Characteristics
5. Fuel Distribution System
4. Storm Water System Number of Deficiencies = 3
Drain Type On-Site Storm Water Management
Surface Run-off N/A
Ownership Maintenance Responsibility System Capacity Adequate System Condition
Center Yes GoodCenter
Comments: Swales and catch basins flow to underground drains. The storm piping running between two site drains near the north corner of Building 22 has collapsed, causing the area between the drains to flood.
Gas Company Metering
Master
Ownership Maintenance Responsibility System Capacity Adequate System Condition
Center Center Yes Good
7. Electrical (Service)
Transformer Maint Resp
Utility,Center
System Capacity Adequate System Condition
Yes Good
Generator
Diesel
ATS MTS
Yes Yes
6. Central Plant: None
Metering Individual
Page: 3 Date: 06/18/2013 of 4
Comments:
Telephone Company
On-site Line Owner
The local telephone company provides five T-1 lines to the center which terminate in the main telephone/server room on the ground level of Building 8. The digital voice over IP (VoIP) and data networks are provided and maintained by Job Corps Data Center. The VoIP, LAN and WAN networks are connected via fiber optic and supported by five 1.5 kVA portable UPS modules. The fire alarm system in buildings throughout the center is connected to the central fire alarm control panel in Security Building 130 and monitored at Gatehouse Building 131 via a computer based monitoring system. Cable TV is provided in dormitories and recreational spaces on the center. The site security system includes an electric gate operator with a remote control located in the gatehouse.
Qwest
Maint. Responsibility
Center Center
Electric gate operator with remote control.
01/06/1993
01/06/1980
01/06/1998
01/01/1965
01/01/1965
N/A
Center
Center
Center
Private
Center
N/A
Active
Active
Active
Active
Closed in Place
N/A
Aboveground
Aboveground
Aboveground
Aboveground
Aboveground
N/A
Building 30
Building 30
Building 30
Near Building 102.
Near Structure 58
N/A
Date of installation is an estimated date.
Yes
Yes
Yes
No
No
No
Petroleum - Diesel Fuel
Petroleum - Waste Oil
Petroleum - Gasoline
Propane
Propane
N/A
STORAGE TANKS
Comments:
TypeStatus Location Owner Fuel Type Capacity (Gallons) Install DateID
Reg.
Number of Deficiencies = 1
9. Electrical (Communication/Alarm/Security)
Equip/Veh Fueling
Waste Oil
Equip/Veh Fueling
Heating
N/A
N/A
Purpose
Yes
Central
VOIP
System Capacity Adequate System Condition
GoodYes
8. Electrical (Site Lighting)
Roadways Parking Walkways Building Outdoor Sports
Mounting
Control
Pole Pole Pole Building Sport Light
Photocell Photocell Photocell, Time Clock Photocell, Time Clock Switch
System Ownership Maintenance Responsibility System Capacity Adequate System Condition
Center Center Yes Good
Comments: The site lighting includes sport lights, street lights, walkway lights and building-mounted lights which are controlled by photocell and time clock, and are owned and maintained by the center.
Number of Deficiencies = 4
Fire Alarm Security
Page: 4 Date: 06/18/2013 of 4
ACCESSIBILITY
Yes
UnknownUnknownUnknownNo
Nationally Registered Site
Site Eligible for National Register
Located in Historic District
Archaeological Significance
Earthquake Risk
Low Medium MediumLow LowIBC Low
LightningEarthquake Def. Authority Flooding Tornado Hurricane Forest
Fire
Most of the center is in a tsunami inundation zone.Comments:
Number of Deficiencies = 1
Accessible Parking: Accessible Slope:
Yes
Curb Cuts:
Yes
Ramps:
YesYes
Site Accessible Route:
GENERAL SITE CONDITION
Rating X Good Fair Poor
HISTORIC PRESERVATION
NATURAL HAZARDS
The site condition is not impacting the functional use of the facilities.
The site condition IS impacting the functional use of the facilities.
The site condition IS SIGNIFICANTLY impacting the functional use of the facilities.
Active Energy Use Reduction Program
Active Water Use Reduction Program
Approximate or Measured Waste Recycled
Use of School Dude or CMMS for Preventative Maintenance
Green Purchasing Policy Practiced
Site Stormwater Absorption Measures in Place
Center has Onsite Renewable Energy (PV or Wind)
Center has a Chartered Green Committee & Roster
Center Uses Green Cleaning Practices
SUSTAINABILITY
NO
NO
NO
NO
NO
NO
NO
NO
Building Descriptions and Utilities
BUILDING 1 - RECREATION/EDUCATION
Building Descriptions
Page: 1 of 201
Building: 0001 - RECREATION/EDUCATION
BUILDING ENVELOPE
Foundation RoofBuilding
Concrete Structural Steel Steel
The mezzanine floor structure is wood.
Brick Masonry Metal Siding Stucco
Wall Roof Batt Rigid
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership#Floors
Assembly 52,565 39,534 2 Owned 1941 Not Evaluated
Comments: The building's fire alarm system has audio/visual devices throughout except in the toilets. There are steps to the rooms.
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
No
No
No
N/A
ACCESSIBILITY
Structural Systems1.
Exterior Walls2. Number of Deficiencies = 1
Insulation4.
Material
The estimated remaining roof life is based on visual observation during the August 2012 Facility Survey.
Drainage Year Life
Remaining Type Area Served
Built-up Roofing
EPDM
Gutters and Downspouts
Interior Roof Drains
Gable
Flat
Original Building
Classrooms
Number of Deficiencies = 1
Comments:
3. Roof
Entire Building
Area Served
Comments:
Page: 2 of 201
Building: 0001 - RECREATION/EDUCATION
INTERIOR FINISH
Carpet Concrete Quarry Tile Rubber Vinyl Tile Wood
Brick CMU Ceramic Tile Drywall Plaster Plywood Wood Paneling
Metal Unit - Metal Frame Overhead Grille - Metal Frame
Safe Door - Metal Frame Wood Unit - Metal Frame
Storefront - Storefront Frame Wood Unit - Wood Frame
VERTICAL CIRCULATION
Concrete Stairs Metal Stairs Ramp Wood Stairs
Metal Rollup - Metal Frame Metal Unit - Metal Frame Storefront - Storefront Frame
Awning Unit - Aluminum Frame; Double Glazing; Awning Units - Steel Frame; Single Glazing;
Fixed - Aluminum Frame; Double Glazing; Fixed - Aluminum Frame; Single Glazing;
Hopper - Steel Frame; Single Glazing; Single Hung - Aluminum Frame; Double Glazing;
Sliding - Aluminum Frame; Double Glazing;
Acoustical Tile Exposed Structure Gypsum Board
Number of Deficiencies = 1
Number of Deficiencies = 2
Exterior Doors5. Number of Deficiencies = 2
Windows6. Number of Deficiencies = 1
Floors1. Asbestos: Yes
Interior Walls2. Number of Deficiencies = 1
3. Number of Deficiencies = 2
Interior Doors4.
Ceilings
Page: 3 of 201
Building: 0001 - RECREATION/EDUCATION
Mechanical
Mechanical
Restroom
Kiln Area
Ventilation Area Served
Split Direct Expansion (Air
Source)
Split Direct Expansion (Air
Source)
Packaged Direct
Expansion (Air Source)
Single Duct
Single Duct
Window Unit
Refrigerant
Refrigerant
None
Electric
Electronic
Electric
Natural
Natural
Mechanical
None
None
None
Classrooms
Classrooms
Recreation Area
Exhaust Ventilation
Most second floor classrooms are cooled by two Carrier model 38CKB060300 systems.
Four Carrier model 40BNB024301 split ductless heat pumps serve the accounting and computer service technician classrooms.
The student store is served by a window unit.
Comments:
Comments:
Comments:
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
The boiler is a Weil McLain model 1188.
Furnaces are gas-fired duct heaters with air handler kits.
Comments:
Comments:
HVAC
Heat1. Asbestos: Yes
Gas-Fired Steam Boiler
Gas-Fired Furnace
Gas-Fired Steam Boiler
Electric Resistance
Radiator
Single Duct
Unit Heater
Baseboard
Two-Pipe
None
Two-Pipe
None
Hand Valves
Electric
Electric
Electric
Natural
Mechanical
Natural
Natural
None
None
None
None
Recreation Area
Recreation Area
Gymnasium
Classrooms
Ventilation2.
System Type
Number of Deficiencies = 1
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
3. Air Conditioning
Page: 4 of 201
Building: 0001 - RECREATION/EDUCATION
The building is served by two 50 gallon water heaters, one of which is a gas-fired Vanguard 5AU70 and the other is an electric Bradford White water heater.
Comments:
Cast-Iron None None
Electric Water Cooler Hose Bibb Lavatory Sink Urinal Water Closet (Flush Valve)
Gas (Natural)
None None ABC Type Fire Extinguisher
Comments: Service is brought from a 150 kVA pad-mounted transformer located outside Academic Building 3 to a 400A main disconnect switch in the Building 1 first floor electrical room. The 150 kVA transformer additionally serves Buildings 3, 5 and 106.
Copper Copper Gas-Fired None No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
High Intensity Discharge (HID)
Comments: Exterior building-mounted light fixtures are controlled by time clock and photocell.
Main Disconnect Switch 120/208V, 3-Phase, 4 Wire Panelboard Receptacles, GFCI, Switches
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING Number of Deficiencies = 1
Water Distribution1.
Sanitary Distribution2.
Fixtures3.
Fuel Distribution4.
FIRE PROTECTION
ELECTRICAL SERVICES
Exterior Lighting1.
LIGHTING
Page: 5 of 201
Building: 0001 - RECREATION/EDUCATION
FIRE ALARM
Comments: The fire alarm control/annunciator panel is a Siemens MXL-IQ located near the building main entrance.
Comments: Classrooms on the second floor are equipped with computer work stations and a printer.
Audible Alarm Control/Annunciator Panel Duct Smoke Detector Flow Switch Heat Detector Manual Pull Station Smoke Detector Tamper Switch Visual Alarm
Connected to Main System None None Local Cable Company
Telephone Security Public Address Television
Comments: Recorded footcandle levels include natural light contribution.
Comments: There are some tritium gas exit signs which expire in 2014.
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
Compact Fluorescent
T8 - Fluorescent
Recreation
Storage/Warehouse-Active
Classrooms
Offices
Corridors & Stairs
Toilets
Equipment Rooms (Elec/Mech)
Area Recommended Level
Recorded Level Light Type
Battery Backup Battery Backup
Emergency Exit
GENERAL BUILDING CONDITION
Rating
Comments:
X Good Fair Poor
The roof over the former control tower (5th floor east tower) was not replaced with the rest of roof in 2011 and is in poor condition.
Interior Lighting2.
Emergency /Exit Lighting3.
COMMUNICATION
The facility condition is not impacting the functional use of the facility.
The facility condition IS impacting the functional use of the facility.
The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.
Electric Water Gas No NoYes
BUILDING UTILITY METERING
Structure: Good Exterior: Good Interior: Good Mechanical: Good Electrical: Good
Type Location None None
Comments: There are gas-fired equipment and appliances in the building.
CARBON MONOXIDE DETECTION
BUILDING 2 - CAFETERIA/CULINARY ARTS
Page: 6 of 201
Building: 0002 - CAFETERIA/CULINARY ARTS
BUILDING ENVELOPE
Foundation RoofBuilding
Concrete Wood Wood
Canopy columns are concrete.
Brick Masonry CMU Masonry Metal Siding
Wall Roof Batt Batt
Metal Rollup - Metal Frame Metal Unit - Metal Frame Storefront - Storefront Frame
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership#Floors
Assembly 15,977 13,335 1 Owned 2007 Not Evaluated
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
N/A
Yes
Yes
N/A
ACCESSIBILITY
Structural Systems1.
Exterior Walls2.
Insulation4.
Exterior Doors5.
Material Drainage Year Life
Remaining Type Area Served
Asphalt Shingles Gutters and Downspouts 2007 15 Gable Entire Building
3. Roof
Entire Building
Page: 7 of 201
Building: 0002 - CAFETERIA/CULINARY ARTS
INTERIOR FINISH
Ceramic Tile Concrete Epoxy Resilient Vinyl Tile Wood
CMU Ceramic Tile Drywall Fiberglass Panel
Metal Unit - Metal Frame Wood Unit - Metal Frame
VERTICAL CIRCULATION
Metal Stairs Ramp
Comments: There are metal stairs leading to the mezzanine floor mechanical rooms. There are concrete stairs and a concrete ramp leading to the entries.
Awning Units - Aluminum Frame; Double Glazing; Casement - Aluminum Frame; Double Glazing;
Fixed - Aluminum Frame; Double Glazing; Sliding - Aluminum Frame; Double Glazing;
Acoustic Board Acoustical Tile Aluminum Foil Insulation Exposed Structure Gypsum Board
Windows6.
Floors1.
Interior Walls2.
3.
Interior Doors4.
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
Dining rooms, serving area and culinary arts are served by five Greenheck PVF duct furnaces with heat inputs ranging from 150 to 500 MBH.
The main kitchen and culinary arts hoods are served by Greenheck PVF makeup air units with heat inputs of 800 and 600 MBH, respectively.
Offices are heated by a Carrier 80 MBH furnace.
Comments:
Comments:
Comments:
HVAC
Heat1.
Gas-Fired Indirect Duct
Furnace
Gas-Fired Indirect Duct
Furnace
Gas-Fired Furnace
Single Duct
Makeup Air Unit
Single Duct
None
None
None
Electric
Electronic
Electronic
Mechanical
Mechanical
Mechanical
None
None
None
Dining Hall
Kitchen
Offices
Page: 8 of 201
Building: 0002 - CAFETERIA/CULINARY ARTS
Mechanical
Mechanical
Mechanical
Kitchen Hood
Dishwashing Hood
Restroom
Hot water is provided by three A.O. Smith model BTH 199 970 condensing water heaters (each: 100 gallons, 199,900 BTUH input and 227.76 GPH recovery, manufactured 12/11/2006).
Comments:
PVC Outdoor None
Electric Water Cooler Fixed Emergency Eyewash Hose Bibb Lavatory Multi-Compartment Sink Sink Urinal Water Closet (Flush Valve)
Gas (Natural)
Wet None ABC Type Fire Extinguisher, K Type Fire Extinguisher
Comments: The main kitchen has three kitchen hood fire extinguishing systems and the culinary arts kitchen has two.
All are UL 300 compliant.
Ventilation Area Served
Copper Copper Gas-Fired None No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Split Direct Expansion (Air
Source)
Fan Coil Refrigerant Electronic Natural None Electronic Equipment
Room
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING
Exhaust Ventilation
Electronic equipment is cooled by a Carrier DFF2AH09J1A split ductless unit.Comments:
Ventilation2.
System Type
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
Water Distribution1.
Sanitary Distribution2.
Fixtures3.
Fuel Distribution4.
FIRE PROTECTION
Page: 9 of 201
Building: 0002 - CAFETERIA/CULINARY ARTS
Comments: Service is brought from a 300 kVA pad-mounted transformer outside the building to a 1200A, 3-section switchboard located in the electrical room. The switchboard has a built in meter in the main section and is protected by a TVSS device.
FIRE ALARM
Comments: The fire alarm control/annunciator panel is a Siemens MXL-IQ located near the electrical room.
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
Audible Alarm Control/Annunciator Panel Duct Smoke Detector Flow Switch Heat Detector Manual Pull Station Smoke Detector Tamper Switch Visual Alarm
Comments: Recorded footcandle levels include natural light contribution. The main dining area is provided with pendant-mounted and decorative compact fluorescent wallsconces. The guest dining area is provided with pendent-mounted indirect lights with T-8 fluorescent. The serving area is provided with recessed compact fluorescent downlights.
High Intensity Discharge (HID)
Comments: Exterior building-mounted light fixtures are controlled by time clock and photocell.
Compact Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
Dining/Lunch Rooms
Food Preparation
Dishwashing
Classrooms
Offices
Corridors & Stairs
Storage Rooms
Toilets
Equipment Rooms (Elec/Mech)
Area Recommended Level
Recorded Level Light Type
Selected Lighting w/ Battery Battery Backup
Switchboard 120/208V, 3-Phase, 4 Wire Panelboard Receptacles, GFCI, Switches
Emergency Exit
ELECTRICAL SERVICES
Exterior Lighting1.
Interior Lighting2.
Emergency /Exit Lighting3.
Location UL300 Compliance Status Main kitchen
Culinary Arts kitchen Compliant
UL300 COMMERCIAL KITCHEN HOOD FIRE SUPPRESSION
Page: 10 of 201
Building: 0002 - CAFETERIA/CULINARY ARTS
Comments: The Culinary arts classroom is provided with TV/VCR for training purposes.
Connected to Main System None None TV with VCR
Telephone Security Public Address Television
GENERAL BUILDING CONDITION
Rating X Good
Fair Poor
COMMUNICATION
The facility condition is not impacting the functional use of the facility.
The facility condition IS impacting the functional use of the facility.
The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.
Electric Water Gas No NoYes
BUILDING UTILITY METERING
Structure: Good Exterior: Good Interior: Good Mechanical: Good Electrical: Good
Type Location None None
BUILDING 3 - ACADEMIC
Page: 11 of 201
Building: 0003 - ACADEMIC
BUILDING ENVELOPE
Foundation RoofBuilding
Concrete Structural Steel Steel
Brick Masonry Storefront and Metal Panels Stucco
Wall Roof None Rigid
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership#Floors
Business 17,848 15,040 2 Owned 1941 Not Evaluated
Comments: The building's fire alarm system has audio/visual devices throughout except in the toilets.
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
N/A
No
No
N/A
ACCESSIBILITY
Structural Systems1.
Exterior Walls2.
Insulation4.
Material
The estimated remaining roof life and age are based on visual observation during the August 2012 Facility Survey.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .