Charleston_Facility_Survey_Vol._2_March_2012.pdf
PDF 5 MB Posted
- Solicitation number
- DOL-ETA-15-R-00057
About this file
J-9 Facility Survey Volume 2
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CharlestonCharleston
Job Corps Center Charleston, WV
Facility Planning ReportFacility Planning Report Volume II
Supporting Data
Fi lFinal March 2012
Department of Labor/ Office of Job Corps
22Charleston Job Corps Center
CharlestonCharleston
Job Corps Center Charleston, WV
Facility Planning ReportFacility Planning Report Volume II
Supporting Data
Fi lFinal March 2012
Dormitories and Commons
33 Charleston Job Corps Center
CONTENTS
CHARLESTON JOB CORPS CENTER
FACILITY PLANNING REPORT
VOLUME I - Planning Strategy
• Existing Site Plan
• Center Statistics
INTRODUCTION
• Purpose
• Report Contents
EXECUTIVE SUMMARY
A. EXISTING CONDITIONS
• Background
• General Site Conditions
• General Building Conditions
• Preventive Maintenance
• Ownership
• Facility Assessment by Function
• Energy
• Environmental Issues
• Sustainability
• Accessibility Standards
• Health and Life Safety Issues
• Summary of Defi ciencies
B. RECOMMENDATIONS
• Status of the Previous (PY08) Plan
• Signifi cant Issues
• PY 11 Plan Overview
• Summary of Proposed Projects
• Regional Projects
• Proposed Site Plan Implementation Plan
• Summary of National Projects
• Project Data Sheets
C. PLANNING ANALYSIS
• Purpose
• Planning Objectives and Assumptions
• Space Utilization Analysis
• Federal Real Property Asset Management
• Mission Dependency Site Plan
• Defi ciency Analysis
• Facility Condition Summary Report
• Building Condition by Function
• Building Condition Site Plan
VOLUME II - Supporting Data
• Vicinity Map
• Location Map
• Existing Site Plan
D. DESCRIPTIONS
• Buildings and Structures
• Space Utilization By Function
• NSF by Building
• Energy Management Report
• Environmental Management
Radon Report
• Site Descriptions
• Building Descriptions
E. DEFICIENCIES
F. CORRESPONDENCE AND REPORTS
• Center Review Meeting Minutes
• Survey Brief
• RA and Student Facility Feedback Questionnaire
• Life Safety Defi ciencies Transmittal and List
• O & M Defi ciency List
• Active Warranty Report
• FRPC Performance Measures Matrix
44Charleston Job Corps Center
55 Charleston Job Corps Center
C harleston Job C orps C enter
77 Charleston Job Corps Center
D Descriptions
BUILDINGS AND STRUCTURES
00303 CHARLESTON 16-FEB-12
1Page: of 1
A - ADMIN/MEDICAL/DENTAL
B - EDUCATION
C - VOCATIONAL
D - CAFETERIA/CULINARY ARTS
E - RECREATION
F - MAINTENANCE/WAREHOUSE
G - RECEPTION/SECURITY
H - FEMALE DORMITORY
I - MALE DORMITORY
M - PUMP HOUSE
N - CARPENTRY
O - MAINTENANCE STORAGE
S - FACILITY MAINTENANCE VOCATION
STORAGE
T - PAINTING VOCATION STORAGE
L - FLAMMABLE STORAGE
P - GAZEBO
Q - GAZEBO
R - GAZEBO
U - GAZEBO
V - GREEN HOUSE
W - STORAGE
X - STORAGE
Name GSF
11,270 10,710 25,140 13,920 24,000 15,450
32,900 32,900
1,050
1,200
Active Active Active Active Active Active Active Active Active Active Active Active Active
Active Active Active Active Active Active Active Active Active
StatusType
Building Building Building Building Building Building Building Building Building Building Building Building Building
Building Structure Structure Structure Structure Structure Structure Structure Structure
Use Group Built Flrs Const
Business Business Business Assembly Assembly Storage Utility/Misc.
Residential Residential Utility/Misc.
Storage Storage Storage
Storage Storage Business Business Business Business Utility/Misc.
Storage Storage
Good Good Good Good Good Good Good Good Good Good Good Good Good
Good Good Good Good Good Good Good Good Good
ConditionAsset Number
0030300002 0030300003 0030300004 0030300005 0030300006 0030300007 0030300008 0030300009 0030300010 0030300014 0030300016 0030300015 0030300020
0030300021 0030300013 0030300017 0030300018 0030300019 0030308110 0030308111 0030308112 0030308113
14 170,746
8 3,160
22 173,906
Buildings
Structures
Total
GSF
GSF
GSF
Summary
Net Square Footage By Building Date: 02/16/2012 Page: 1Center: CHARLESTON (00303) of 4
HOUSING
Sleeping
Lounge
Storage
Shower/Toilet
Other
Function Suggested NSF
13,584 13,584
3,424 3,424
2,388 2,388
1,894 1,894
H - FEMALE DORMITORY
I - MALE DORMITORY
H - FEMALE DORMITORY
I - MALE DORMITORY
I - MALE DORMITORY
H - FEMALE DORMITORY
I - MALE DORMITORY
H - FEMALE DORMITORY
H - FEMALE DORMITORY
I - MALE DORMITORY
Bldg Name Actual NSF Difference
27,168
6,848
4,776
3,788
Sub Total: 43,054
23,904
3,320
1,992
3,984
33,200
3,264
3,528
-1,518
3,788
( 332
9,854
Page: 2Center: CHARLESTON (00303) of 4
EDUCATION
Academic
Vocational Theory (172)
Carpentry
Health Occupations
Culinary Arts
Painting
Network Cable Installer
HVAC
Facilities Maint. and Const.
Non-Academic
Business Office Technologies
Medical Office Specialist
Function Suggested NSF
1,168
2,007
2,814
1,436
1,724
1,126
2,880
2,077
3,261
1,084
2,433
1,849
1,944
B - EDUCATION
B - EDUCATION
B - EDUCATION
B - EDUCATION
D - CAFETERIA/CULINARY ARTS
C - VOCATIONAL
N - CARPENTRY
C - VOCATIONAL
C - VOCATIONAL
D - CAFETERIA/CULINARY ARTS
T - PAINTING VOCATION STORAGE
N - CARPENTRY
C - VOCATIONAL
C - VOCATIONAL
C - VOCATIONAL
S - FACILITY MAINTENANCE VOCATION STOR
C - VOCATIONAL
F - MAINTENANCE/WAREHOUSE
B - EDUCATION
B - EDUCATION
H - FEMALE DORMITORY
E - RECREATION
C - VOCATIONAL
E - RECREATION
I - MALE DORMITORY
B - EDUCATION
B - EDUCATION
C - VOCATIONAL
C - VOCATIONAL
Bldg Name Actual NSF Difference
2,692
2,392
3,154
1,436
1,724
4,346
2,077
3,825
8,544
1,944
Sub Total: 34,069
3,900
1,720
1,500
1,500
1,800
3,600
3,900
18,820
-1,208
1,654
1,436
1,724
2,846
4,644
1,944
( 390
15,249
Page: 3Center: CHARLESTON (00303) of 4
FOOD SERVICE
RECREATION
MEDICAL/DENTAL
ADMINISTRATION
Dining (2 Servings)
Food Preparation
Food Storage
Multipurpose Room
Recreation Hall
Arts & Crafts
Gymnasium
Weight Room
Student Store
Miscellaneous Recreation
Recreation/Snack Bar
Recreation Storage
Recreation Office
Medical/Dental
Administration
Function Suggested NSF
4,026
2,421
1,296
1,565
8,235
1,048
1,082
2,715
4,480
D - CAFETERIA/CULINARY ARTS
D - CAFETERIA/CULINARY ARTS
D - CAFETERIA/CULINARY ARTS
E - RECREATION
E - RECREATION
E - RECREATION
E - RECREATION
E - RECREATION
E - RECREATION
E - RECREATION
E - RECREATION
E - RECREATION
E - RECREATION
A - ADMIN/MEDICAL/DENTAL
A - ADMIN/MEDICAL/DENTAL
G - RECEPTION/SECURITY
Bldg Name Actual NSF Difference
4,026
2,421
1,296
1,565
8,235
1,048
1,082
2,715
4,950
Sub Total:
Sub Total:
Sub Total:
Sub Total:
7,743
15,280
2,715
4,950
3,120
2,340
1,560
2,070
7,800
7,020
17,470
2,070
7,800
-264
-2,850
-2,190
-2,850
Page: 4Center: CHARLESTON (00303) of 4
STORAGE/SUPPORT
Warehouse
Operations & Maintenance
Function Suggested NSF
7,524
1,030
7,118
F - MAINTENANCE/WAREHOUSE
O - MAINTENANCE STORAGE
M - PUMP HOUSE
F - MAINTENANCE/WAREHOUSE
Bldg Name Actual NSF Difference
7,524
8,369
Sub Total: 15,893
4,680
3,120
7,800
2,844
5,249
( 390
8,093
February 16, 2012 Space Utilization By Function 00303 Charleston
Page: 1 of 2
HOUSING
EDUCATION
FOOD SERVICE
SUGGESTED
NSF/
ENROLLEE
SUGGESTED
TOTAL
NSF
ACTUAL
TOTAL
NSF
TYPE OF SPACE
SUB TOTAL
SUB TOTAL
SUB TOTAL
Resident Men Resident Women Total Residents
Residents 332 Non Residents 58
390Total Students
(332)
(390)
(390)
DIFFERENCE
33,200
27,520
7,020
43,054
34,069
7,743
Lounge Other Shower/Toilet Sleeping Storage
Academic (390) Non-Academic
45 -- ACT (Off-Ctr) 0 -- Business Office Technologies 20 -- Carpentry + 30 -- Cert. Nursing Asst.
0 -- Culinary Arts + 30 -- Dental Assistants + 48 -- Facilities Maint. and Const. +
24 -- HVAC +
0 -- Health Occupations + 0 -- Medical Office Specialist 30 -- Medical Office Support 30 -- Network Cable Installer
25 -- OCT
90 -- Office Administration 20 -- Painting + 30 -- Pharmacy Tech +
Vocational Theory (172)
Dining (2 Servings) Food Preparation Food Storage
6,848 3,788 4,776
27,168
2,692 8,544
1,944 3,154
1,724
3,825 2,077 1,436
4,346
2,392
4,026 2,421 1,296
3,320
3,984 23,904
1,992
3,900 3,900
1,500 1,200
1,200 3,600 1,800
4,050 1,500 1,350
1,720
3,120 2,340 1,560
3,528
3,264 -1,518
-1,208 4,644
1,654
2,846
-264
Vocations
9,854
6,549
February 16, 2012 Space Utilization By Function 00303 Charleston
Page: 2 of 2
RECREATION
MEDICAL/DENTAL
ADMINISTRATION
STORAGE/SUPPORT
SUGGESTED
NSF/
ENROLLEE
SUGGESTED
TOTAL
NSF
ACTUAL
TOTAL
NSF
TYPE OF SPACE
SUB TOTAL
SUB TOTAL
SUB TOTAL
SUB TOTAL
TOTAL 263.79 102,880 123,704
(390)
(390)
(390)
(390)
DIFFERENCE
170,746
0.72
TOTAL GSF
NET TO GROSS RATIO
17,470
2,070
7,800
7,800
15,280
2,715
4,950
15,893
Arts & Crafts Gymnasium Miscellaneous Recreation Multipurpose Room Recreation Hall Recreation Office Recreation Storage Recreation/Snack Bar Student Store Weight Room
Medical/Dental
Administration
Operations & Maintenance Warehouse
5.31
8,235 1,082
1,565
1,048
2,715
4,950
8,369 7,524
2,070
7,800
3,120 4,680
-2,850
5,249 2,844
RESIDENT
NON-RESIDENT
(332)
(58) 15
50 16,600
-2,190
-2,850
8,093
20,824
Energy Management Report Center: CHARLESTON (00303)
Page: 1 Date: 02/16/2012 of 3
CENTER ENERGY DATA
Deferred (new center)
ENERGY CONSUMPTION ASSESSMENT
16% 72,084 70,023 85,393
ENERGY USE BY FUEL TYPE
Energy Audit :
Date of Audit :
Electric Company :
Percent Reduction since Baseline Year :
Natural Gas Company :
Property Status :
N/A
American Electric Columbia Gas
Federally Owned (DOL)
2,300,720 7,850=
Total 12,308
MBtu
MBtu
Total $288,610 MBtu/ $23.449
BTU/GSF
BTU/GSF
BTU/GSF
Electricity
Natural Gas kWh
4,324 MCF = 4,458 MBtu
$220,990 $0.096= kWhElectricity
Natural Gas $67,620 = $15.638 MCF
ENERGY COST BY FUEL TYPE
WATER CONSUMPTION ASSESSMENT
FY 2007 Baseline:
Percent Reduction Since Baseline Year:
1,000 Gallons
1,000 Gallons
FY 2011 Energy Goal:
Further Reduction in Energy Usage is needed to meet Energy Reduction Goals.
FY 2011 Energy Consumption:
Note: The Federal Government has set a goal of 3% Energy Consumption Reduction per year in EO 13423.
8,713 8,016 7,165
18%
Water Goals are being met. Keep reducing Water Consumption.
Note: The Federal Government has set a goal of 2% Water Consumption Reduction per year in EO 13423.
FY 2011 Goal:
FY 2011 Water Consumption:
1,000 Gallons
FY 2003 Energy Baseline:
Page: 2 Date: 02/16/2012 of 3
Implementing some of the below recommendations can save you 10% to 25% off your annual energy bill without negatively impacting comfort or productivity.
1. Your staff and students are the key to savings. Educate the students and staff on the why of energy saving - costs and environmental impacts. Encouraging them to actively participate in energy reduction is also important. Post reminders at exit doors and bulletin boards about energy conservation. Simple tips include:
a. Turn it down (lights, heating & cooling),
b. Turn it off (lights, computers, other equipment),
c. Keep it tight (close doors and windows, use window blinds)
2. Operations and Maintenance: Educate the O&M staff on the why of energy saving -costs and environmental impacts. Simple tips include:
a. Make sure that the Operations and Maintenance staff is properly trained for the equipment they operate.
b. Tune and clean HVAC: Perform seasonal cleanups on air conditioners, boilers and furnaces, and regularly clean cooling coils and drain pans. Get rooftop or outdoor condenser coils cleaned and maintain an appropriate filter changing schedule.
c. Check (or ask your HVAC contractor to check) your outside air dampers or economizers to verify proper ventilation. Make sure economizer controls function properly. Make sure automatic dampers close during unoccupied periods.
d. Restore automatic control: When troubleshooting a system, take time to figure out and repair the automatic controls. Today's quick fix is tomorrow's bad idea.
e. Reasonable set points: Try 68°F in the heating season and 75°F in the cooling season.
f. Schedule HVAC equipment and lighting: (weekdays, weekends, holidays, off-season). Make sure equipment runs only when it is needed and the buildings are occupied. When buildings are vacant (i.e. dormitories during the day with students in class), make sure all the lights in the building are off.
g. Seasonal (resets, schedules, and shutoffs): As the seasons change, adjust set points and schedules to match the system's response to the weather.
h. Lighting: Invest in an inexpensive light level meter to measure the foot-candles in spaces to determine whether or not they are over lit and lamps can be safely removed. Where four-lamp fixtures are in use, two lamps can usually be removed from every fixture or every other fixture. After lamps are removed, disconnect ballasts. Contact the Energy team at PBDewberry for suggested light levels for individual space types. Cleaning fixtures regularly increases light levels.
i. Utilize power management features for all computers and monitors to shut them off when idle for more than 15 minutes.
Page: 3 Date: 02/16/2012 of 3
j. Have your vending machine suppliers turn off or remove light tubes from the advertising lighting in the machine. This will save about $50 per year per vending machine.
k. Save water with low flow sink aerators (0.5gpm) and low flow shower heads (1.5gpm - 2.0gpm). This will also reduce water heating energy consumption.
l. Set your water heater to 120°F. Verify by measuring at the tap. Never go below 115°F.
m. For water heaters installed in unconditioned spaces, add insulation blankets making sure that access covers, electric connection areas, and pressure relief valves are left uncovered.
n. Caulk and fill cracks around doors and windows to reduce costly air leaks.
o. When replacing broken glass, use high transmittance, low heat gain windows.
p. Make sure automatic door closers are functioning properly to avoid drafts.
3. Buy energy efficient, buy EnergyStar (www.energystar.gov).
a. Buy EnergyStar appliances and equipment.
b. Replace burned out lightbulbs with EnergyStar labeled compact fluorescent lightbulbs (CFLs).
c. Replace broken thermostats with EnergyStar labeled programmable products.
d. Replace broken exit signs with EnergyStar LED exit signs.
Environmental Management Report
Page: 1 Date: 02/16/2012 of 1
SOLID & HAZARDOUS WASTE MANAGEMENT (RCRA)
Commercial Waste Service
HAZARDOUS MATERIALS STORAGE (EPCRA)
No Buildings L, N, O
Organic solvent (50 gals), propane (50 lbs), oil-based paint (100 gals) Yes
PETROLEUM UNDERGROUND STORAGE TANKS (RCRA)
N/A0
PETROLEUM ABOVEGROUND STORAGE TANKS (CWA)
ASBESTOS AND PCB MANAGEMENT (TSCA)
AIR POLLUTION CONTROL (CAA)
N/A None
Attainment
Solid Waste Disposal :
Hazardous Waste Generator :
Hazardous Waste ID :
Generator Classification :
Hazadous Materials Storage :
Hazardous Materials ID :
HazMat Storage Area :
HazMat Spill Response Plan :
Number of Regulated USTs :
Number of Un-regulated USTs :
Local Hazardous Use Permit :
LEPC Notification :
EPA Generator ID Number :
Hazardous Waste Disposal :
RCRA Compliance
ID LocationFuel Type Capacity
Number of ASTs :
Asbestos Survey Date :
Asbestos Type :
Asbestos Coordinator :
Coordinator Training Date:
Custodial/Maintenance Training :
AHERA Regulated :
Management Plan Approval :
PCB Transformer Testing :
PCB Transformers :
PCB-Contaminated Transformers :
Transformers Labelled :
Regional Air Quality :
Permitted Air Pollution Source :
Source Description :
Williams Waste Management No N/A
N/A N/A N/A
N/A
No No
Overfill Leak Corrosion
SPCC Plan Required : SPCC Plan Completed :
No N/A
No Survey Performed None N/A
N/A N/A
No Yes
ID Fuel Type Capacity Location Overfill
Prevention Secondary Containment
1 Petroleum - Diesel Fuel 100 Inside Building M Yes Yes
Tank Status Active
Tank Status Prevention/Detection
Radon
Date: Feb. 16, 2012Center : Charleston (00303) Page: 1 of 1
A - ADMIN/MEDICAL/DENTAL
B - EDUCATION
C - VOCATIONAL
D - CAFETERIA/CULINARY ARTS
E - RECREATION
F - MAINTENANCE/WAREHOUSE
G - RECEPTION/SECURITY
H - FEMALE DORMITORY
I - MALE DORMITORY
M - PUMP HOUSE
N - CARPENTRY
O - MAINTENANCE STORAGE
S - FACILITY MAINTENANCE VOCATION STORAGE
T - PAINTING VOCATION STORAGE
Bldg Name
02/14/2004
02/16/2004
02/14/2004
Test Date
Yes
No
Yes
No
No
Yes
No
No
No
N/A
N/A
N/A
N/A
N/A
Radon Testing
< 4 pCi
< 4 pCi
< 4 pCi
Test Result
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Mitigation Mitigation Date
RADON EXPLANATORY NOTES
The US Environmental Protection Agency (EPA) has established a radon action level of 4.0 picoCuries per liter (pCi/L). Occupied buildings with radon concentrations less than 4.0 pCi/L do not require radon mitigation; un-occupied buildings, or those buildings which are occupied only infrequently for brief periods of time, also do not require radon mitigation. Occupied buildings with radon concentrations greater than
4.0 pCi/L require radon mitigation and verification of radon reductions as soon as possible, with priority given to dormitories and student recreation buildings. Occupied buildings with radon concentrations greater than 20.0 pCi/L should be considered significant radon exposure hazards, and priority for mitigation should be given to buildings with these highly elevated radon concentrations.
Radon mitigation techniques include: (1) adjustment of the building HVAC system to create a positive pressure within the building; (2) sealing of foundation wall cracks, penetrations, or other openings;
(3) sealing crawlspace openings and sump pits; (4) installing an active subslab depressurization (ASD) system.
303 Ch l t J b C C t303 Charleston Job Corps Center Site Description
View of Parking at Entrance to Center
Page: 1 Date: 02/16/2012 of 4
Comments:
Paving Type for Roads & Parking
There is a speed bump by Reception/Security Building G. There is a vehicular drive around the site perimeter.
Concrete sidewalks provide internal pedestrian circulation.
Paving Type for Sidewalks
Asphalt Concrete
Comments:
Topography Buildings and Structures
Center is not fully enclosed by fencing. There are landscape features on the student promenade. The site is partially fenced on the north side between the parking lot and vehicular drive and on the south side along the vehicular drive and baseball field. Two signs are on the access road near the center entrance. There are two metal entrance gates, one manual and one electronic.
ROADS, PARKING & SIDEWALKS
Water Source Water Authority Service Meter On-Site Treatment Plant
1. Water System
Treatment Type Storage Type Storage Capacity(Gallons)
NoMasterCity of CharlestonAmerican Water Systems
Source Water Disinfection 0None
The meter is located just west of Pump House Building M.Comments:
Comments:
Fire Hydrants On-Site Water Supply Storage Capacity
(Gallons) Pressure Source FD Response Time (Minutes)
Yes 0 10None Fire Pump
The Center is served by a Peerless Pump Company duplex pump set powered by two Magnatek 7-1/2 HP, 1760 RPM motors. In the case of a power outage, the Center will be served by an emergency pump (Peerless Pump Company #4AFF11, 750 GPM at 55 PSI, 31 BHP) powered by a Clarke diesel-fueled engine. The 100 gallon fuel tank is within the building.
Number of Deficiencies = 2
SITE FEATURES
UTILITIES
2. Fire Protection System
Buildings Structures14 8Flat
Surrounding
Outdoor Recreation
Forest, Light Commercial
Basketball, Soft/Baseball Flagpoles
Entrance
Southern Boundary
Ornamental Metal
Chain Link
Location Type
Maintenance Responsibility System Capacity Adequate System Condition
Center Center Yes Good
Separate Loop
No
Ownership Maintenance Responsibility System Capacity Adequate System Condition
Center Center Yes Good
Ownership
Roads & Parking Adequate Roads & Parking Condition Sidewalks Adequate Sidewalk Condition Yes Good Yes Good
Fencing
Other Features
Page: 2 Date: 02/16/2012 of 4
Sewage Treatment Flow
Center
Publicly Owned Treatment Works
Center
Gravity
Maintenance ResponsibilityOwnership
Comments: Each building is metered individually.
Columbia Gas
Comments:
Electric Company PCB Trans.
Transformer Mounting Transformer Ownership
Systems Ownership Maintenance Responsibility
American Electric
The primary distribution on the center is a 12.47/7.2kV underground loop which feeds pad-mounted transformers ("Y/Y" configuration) which step the voltage down to 208/120V, 3-Phase, 4 Wire. The major buildings: A, B, C, D, E, F, H and I are separately metered by secondary meters at the buildings. Building G is sub-fed from Building D and Building M is sub-fed from Building E by zone metering at the major buildings. Buildings L and O are sub-fed from Building F by zone metering. There is one center-owned 30 kVA natural gas Kohler Power generator with a 100A automatic transfer switch (Kohler). The generator, which is located next to the cafeteria building, provides power for some refrigeration and kitchen loads, for one packaged roof top unit, for limited lighting loads, and for life safety.
Pad Utility
Utility Utility
No
12.47/7.2kV, 3-Phase
208Y/120, 3-Phase, 4 WIreUnderground
UndergroundPrimary Service
Secondary Service
Distribution Characteristics
3. Sanitary Sewer System/ Sewage Treatment Plant
5. Fuel Distribution System
Number of Deficiencies = 7
System Capacity Adequate System Condition
Yes Good
4. Storm Water System Number of Deficiencies = 9
Drain Type On-Site Storm Water Management
Surface Run-off Underground Storage
Ownership Maintenance Responsibility System Capacity Adequate System Condition
Center Yes GoodCenter
Comments: An underground stormwater detention system, consisting of three corrugated metal pipe structures, slows stormwater run-off away from the center.
Gas Company Metering
Individual
Ownership Maintenance Responsibility System Capacity Adequate System Condition
Utility Center Yes Good
7. Electrical (Service)
Transformer Maint Resp
Utility
System Capacity Adequate System Condition
Yes Good
Generator
Natural Gas
ATS MTS
Yes No
6. Central Plant: None
Metering Individual
Page: 3 Date: 02/16/2012 of 4
Comments:
Telephone Company
On-site Line Owner
Fire alarm panels of Buildings A-F, H and I and fire alarm devices in Building M are connected and monitored by a central control/annunciator panel in Security Building G. The center's fire alarm equipment was manufactured by Simplex.
The center telephone communication system is provided by the JCDC. The main data closet (MC) is located in the main electrical room in Building A. One PRI circuit is used for VoIP. Fax numbers are routed through the VoIP system using a Cisco VG224 analog/digital voice gateway. Out of 100 DID's 10 numbers are reserved for faxes.
The center also has 5 POTS lines terminated at MC in Building A, used exclusively for emergencies in the event the main system goes down.
All internet traffic is carried through (4) T1 lines split between Routers 1 and 2. Switch 1 connects Routers 1 and 2 to the network. Two dedicated T1 lines carry all Citrix traffic. Citrix traffic is separated at Router 1, located in MC in Building A. Content is filtered by the use of "Blue Coat" also connected to Switch 1 located in MC. The network consists of a fiber backbone connecting each building to Building A, Switch 1. MC in Building 1 houses Routers 1 and 2, Switch 1, Blue Coat and the VG224 (on the rack). The MC is connected to a UPS back-up system. Each switch on center has fiber connecting them to the network. Most are connected all the way back to Switch 1, however there are areas that have more than one switch and these areas are connected switch to switch using fiber between them. The computers and phones are connected by CAT5 cables to the switches in each building's mechanical/electrical rooms.
CCTV cameras are located throughout the campus inside and outside the buildings. Information from the cameras is saved in Buildings A, H, and I. Building G was provided with central monitoring capabilities. The central monitoring system is currently not operational. There is Direct TV satellite television in Buildings A, H and I.
NTelos (FiberNet)
Maint. Responsibility
Center Center
Closed Circuit TV
10/01/1997CenterActive AbovegroundInside Building M
The tank stores diesel fuel for the emergency fire pump.
NoPetroleum - Diesel Fuel
STORAGE TANKS
Comments:
TypeStatus Location Owner Fuel Type Capacity Install DateID
Reg.
9. Electrical (Communication/Alarm/Security)
Other
Purpose
Yes
Central
VOIP
System Capacity Adequate System Condition
GoodYes
8. Electrical (Site Lighting)
Roadways Parking Walkways Building Outdoor Sports
Mounting
Control
Pole Pole Pole Building Sport Light
Time Clock Time Clock Time Clock Photocell Switch
System Ownership Maintenance Responsibility System Capacity Adequate System Condition
Center Center Yes Fair
Comments: The site and sports high intensity discharge lighting on center is owned and maintained by the center. Walkway lighting, provided via pole-mounted square type decorative light fixtures, is served from Buildings C, G and I and is controlled by time clocks located in the corresponding buildings. Sports lighting is manually controlled by pole-mounted key operated switches. Softball lighting (four poles with five light fixtures and two poles with two light fixtures each) is served from Building B and basketball lighting (four poles with two light fixtures each) is served from Building D. Roadway and parking lighting, provided via pole-mounted shoe-box type light fixtures, is controlled by time clock and are served from Building G, which also provides for flag pole lighting (flood uplights). Building-mounted HID wall packs and canopy-mounted recessed HID light fixtures, controlled by building-mounted photocells, are utilized for building exterior lighting.
Number of Deficiencies = 4
Number of Deficiencies = 5
Fire Alarm Security
Page: 4 Date: 02/16/2012 of 4
ACCESSIBILITY
Yes
There is a bus parking area in the main parking lot at the entry.Comments:
UnknownUnknownUnknownNo
Nationally Registered Site
Site Eligible for National Register
Located in Historic District
Archaeological Significance
Earthquake Risk
Low Medium LowMedium LowIBC Low
LightningEarthquake Def. Authority Flooding Tornado Hurricane Forest
Fire
Occasionally wild animals such as foxes, bears, and deer, come onto the site from the surrounding forest.Comments:
Number of Deficiencies = 2
Accessible Parking: Accessible Slope:
Yes
Curb Cuts:
Yes
Ramps:
YesYes
Site Accessible Route:
GENERAL SITE CONDITION
Rating X Good Fair Poor
HISTORIC PRESERVATION
NATURAL HAZARDS
The site condition is not impacting the functional use of the facilities.
The site condition IS impacting the functional use of the facilities.
The site condition IS SIGNIFICANTLY impacting the functional use of the facilities.
Building Descriptions and Utilities Charleston
BUILDING A ADMIN/MEDICAL/DENTALBUILDING A - ADMIN/MEDICAL/DENTAL
Building Descriptions
Page: 1 of 65
Building: A - ADMIN/MEDICAL/DENTAL
BUILDING ENVELOPE
Foundation RoofBuilding
Concrete Loadbearing Masonry Wood / Steel
CMU Masonry EIFS
Wall Roof Batt Batt
Metal Unit - Metal Frame Storefront - Storefront Frame
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership#Floors
Business 11,270 7,195 1 Owned 1997 Unevaluated
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
Yes
N/A
Yes
Yes
Yes
Yes
Yes
N/A
N/A
Yes
Yes
N/A
ACCESSIBILITY
Structural Systems1.
Exterior Walls2.
Insulation4.
Exterior Doors5.
Material Drainage Year Life
Remaining Type Area Served
Asphalt Shingles
EPDM
Gutters and Downspouts
Interior Roof Drains
Hip
Flat
Medical/Dental/Of fices
Storage/Lounge
Number of Deficiencies = 23. Roof
Entire Building
Area Served
Page: 2 of 65
Building: A - ADMIN/MEDICAL/DENTAL
INTERIOR FINISH
Carpet Ceramic Tile Vinyl Tile
Ceramic Tile Drywall
Metal Unit - Metal Frame Storefront - Metal Frame
Wood Unit - Metal Frame
Mechanical
Mechanical
Restroom
Janitor's Closet
Comments:
Comments:
A rooftop exhaust fan (Loren Cook #180ACE180C11D, 3/4 HP, built 1/2008) ventilates the four public restrooms. Small ceiling fans ventilate the other medical/dental restrooms.
This room is ventilated by a ceiling fan.
Ventilation Area Served
VERTICAL CIRCULATION
Metal Ladder
Comments: There is a steel ladder to access the roof.
Fixed - Aluminum Frame; Double Glazing; Single Hung - Aluminum Frame; Double Glazing;
Sliding - Aluminum Frame; Single Glazing;
Acoustical Tile Gypsum Board
Exhaust Ventilation
Number of Deficiencies = 1
Number of Deficiencies = 1
Windows6.
Floors1. Number of Deficiencies = 1
Interior Walls2.
3.
Interior Doors4. Number of Deficiencies = 1
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
Five rooftop units (Trane #YCD090D3LOBE, 97.2 MBH output, built 4/1996) serve this building.
There are four serving the three entryways and one office.
Comments:
Comments:
HVAC
Heat1.
Gas-Fired Packaged
Electric Resistance
Single Duct
Wall Heaters
None
None
Electronic
Electric
Mechanical
Natural
None
None
Entire Building
Vestibules
Ventilation2.
Ceilings
Page: 3 of 65
Building: A - ADMIN/MEDICAL/DENTAL
There are two gas-fired water heaters (Bradford-White #MITW50L6LN10, 48 gallon).Comments:
Cast Iron None Cast Iron
Electric Water Cooler Lavatory Mop Sink Multi-Compartment Sink Shower/Bathtub Sink Urinal Wall Hydrant Water Closet (Flush Valve)
Gas (Natural)
Wet None ABC Type Fire Extinguisher
Copper Copper Gas-Fired None No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Packaged Direct
Expansion (Air Source)
Split Direct Expansion (Air
Source)
Single Duct
Fan Coil
None
Refrigerant
Direct Digital Control (DDC)
Electric
Mechanical
Natural
None
None
Entire Building
Electronic Equipment
Room
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING
Five rooftop units (Trane #YCD090D3LOBE, 7-1/2 ton, built 4/1996) serve this building.
This room is served by a ductless split system (Trane #T7K536, 3 ton, built 3/2004) as is the adjacent storage room (Trane #T7K518, 1-1/2 ton. built 3/2004).
Comments:
Comments:
System Type
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
Water Distribution1.
Sanitary Distribution2.
Fixtures3.
Fuel Distribution4.
FIRE PROTECTION
3. Number of Deficiencies = 1Air Conditioning
Page: 4 of 65
Building: A - ADMIN/MEDICAL/DENTAL
Comments: Underground service from a 225 kVA pad-mounted transformer (30 kV, Imp. 2.1%) located near the north building's corner is provided to a 600A main distribution panel with a 600A main circuit breaker (MCB).
The main panel is protected by a secondary MOV surge arrester (Joslyn Mfg., Surge Tech Z-650, 650V max). The main panel serves two 225A main-lug-only (MLO) two-section panels A1 and A2 (from 225A circuit breakers (CB), and 5 ACU units (from (1) 45A, (1) 40A, (2) 30A and (1) 25A CB). Panel A1 is providing for the administration wing and panel A2 for the medical/dental wing. The main distribution panel and panel A1 are located in the main electrical room. Panel A2 is located in the storage room of the dental wing. All panels are by Cutler-Hammer, built 04/96, PRL3A and PRL1 type. This building is protected by a lightning protection system. The utility meter is located at the north wall of the main electrical room. Same transformer also serves Building E.
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
Comments: Recorded footcandle levels include natural light contribution. Occupancy sensors are utilized throughout the administration portion of the building.
Comments: Remote head emergency light fixtures are utilized at the exterior exits, each has battery backup (Embassy, EMB-6CE 12T1, 6V Sealed Lead Acid batteries) located inside the building. The tritium gas exit signs manufactured in March 1996 have a stated life of 20 years.
High Intensity Discharge (HID)
Comments: Exterior lighting is controlled by fixture-mounted photocells. Recessed HID light fixtures are provided above the main entrances.
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
Compact Fluorescent
Offices
Medical/Dental
Storage Rooms
Wards (Patient)
Reception
Conference Rooms
Corridors & Stairs
Toilets
Housing Lounge
Equipment Rooms (Elec/Mech)
Mail Room
Toilets
Area Recommended Level
Recorded Level Light Type
Selected Lighting w/ Battery Tritium Gas
Main Distribution Panel 120/208V, 3-Phase, 4 Wire Panelboards Receptacles, GFCI, Switches
Emergency Exit
ELECTRICAL SERVICES Number of Deficiencies = 3
Exterior Lighting1.
Interior Lighting2.
Emergency /Exit Lighting3. Number of Deficiencies = 1
LIGHTING
Page: 5 of 65
Building: A - ADMIN/MEDICAL/DENTAL
FIRE ALARM
Comments: The fire alarm panel is a Simplex 4020 located in the reception area. The local annunciator is a Simplex 4602-8001, located in the main vestibule. The fire alarm system is additionally monitored in Reception/Security Building G.
Comments: The center telephone communication system is provided by the JCDC to the main data closet (MC) located in the main electrical room. MC houses Routers 1 & 2, Switch 1, Blue Coat and the VG224.
UPS is used for power backup. One PRI circuit is used for VoIP. Fax numbers are also routed through the VoIP system using a Cisco VG224 analog/digital voice gateway. Out of 100 DID's a bank of 10 numbers is reserved for faxes. The center also has 5 POTS lines terminated at MC and used exclusively for emergencies. All internet traffic is carried through (4) T1 lines split between Routers 1 &
2. Switch 1 connects Routers 1 and 2 to the network. Two dedicated T1 lines carry all Citrix traffic.
Citrix traffic is separated at Router 1, located in MC in Building A. Content is filtered by the use of Blue Coat also connected to Switch 1 located in MC. The network consists of a fiber backbone connecting buildings to Building A, Switch 1. Computers & phones in the building are connected by CAT 5 cables.
Audible Alarm Control/Annunciator Panel Duct Smoke Detector Heat Detector Manual Pull Station Remote Annunciator Smoke Detector Visual Alarm
Connected to Main System Magnetic Door/Alarm None Satellite Dish
Telephone Security Public Address Television
GENERAL BUILDING CONDITION
Rating X Good
Fair Poor
COMMUNICATION
The facility condition is not impacting the functional use of the facility.
The facility condition IS impacting the functional use of the facility.
The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.
Electric Water Gas No YesYes
BUILDING UTILITY METERING
Structure: Good Exterior: Good Interior: Good Mechanical: Good Electrical: Good
BUILDING B EDUCATIONBUILDING B - EDUCATION
Page: 6 of 65
Building: B - EDUCATION
BUILDING ENVELOPE
Foundation RoofBuilding
Concrete Loadbearing Masonry Wood
CMU Masonry EIFS
Wall Roof Batt Batt
Metal Unit - Metal Frame Storefront - Storefront Frame
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership#Floors
Business 10,710 6,793 1 Owned 1997 Unevaluated
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
Yes
N/A
Yes
Yes
Yes
Yes
Yes
N/A
N/A
Yes
Yes
N/A
ACCESSIBILITY
Structural Systems1.
Exterior Walls2.
Insulation4.
Exterior Doors5. Number of Deficiencies = 2
Material Drainage Year Life
Remaining Type Area Served
Asphalt Shingles Gutters and Downspouts 1997 6 Hip Entire Building
3. Roof
Page: 7 of 65
Building: B - EDUCATION
INTERIOR FINISH
Carpet Ceramic Tile Vinyl Tile
CMU Ceramic Tile Drywall
Aluminum Storefront - Aluminum Frame Folding - Aluminum Frame
Metal Unit - Metal Frame Wood Units - Metal Frame
Mechanical Restroom
Ventilation Area Served
VERTICAL CIRCULATION
None
Fixed - Aluminum Frame; Double Glazing; Single Hung - Aluminum Frame; Double Glazing;
Acoustical Tile Exposed Structure Gypsum Board
Exhaust Ventilation
Number of Deficiencies = 1
Windows6. Number of Deficiencies = 1
Floors1.
Interior Walls2.
3.
Interior Doors4. Number of Deficiencies = 5
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
There are three units (two Trane #YCH120C3MOAB, 166 MBH output, 4000 CFM; and a Trane #YCH060C3LOBE, 72.9 MBH output, 2000 CFM) serving this building. All units are on grade behind the building.
There is an electric heater at each of the four entrances to the building.
Comments:
Comments:
HVAC
Heat1.
Gas-Fired Packaged
Electric Resistance
Single Duct
Unit Heater
None
None
Electronic
Electric
Mechanical
Natural
None
None
Entire Building
Vestibules
Ventilation2. Number of Deficiencies = 1
Page: 8 of 65
Building: B - EDUCATION
The water heater (Bradford White, 48 gallon, 32 MBH output) is located in the exterior mechanical equipment room.`
Comments:
Cast Iron None None
Electric Water Cooler Lavatory Mop Sink Urinal Water Closet (Flush Valve)
Gas (Natural)
None None ABC Type Fire Extinguisher
Copper Copper Gas-Fired None No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Packaged Direct
Expansion (Air Source)
Single Duct None Electronic Mechanical None Entire Building
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING
There are three units (two Trane #YCH120C3MOAB, 10 ton, 4000 CFM; and a Trane #YCH060C3LOBE, 5 ton, 2000 CFM) serving this building. All units are on grade behind the building.
Comments:
Number of Deficiencies = 1
System Type
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
Water Distribution1.
Sanitary Distribution2.
Fixtures3.
Fuel Distribution4.
FIRE PROTECTION
3. Air Conditioning
Page: 9 of 65
Building: B - EDUCATION
Comments: Underground service from a 150 kVA pad-mounted transformer (30 kV, Imp. 1.9%) located just east of the building is provided to a 600A main distribution panel with a 600A main circuit breaker (MCB). The main panel is protected by a secondary MOV surge arrester (Joslyn Mfg., Surge Tech Z-650, 650V max). The main panel serves three 225A main-lug-only (MLO) panels B1, B2 and B3 (from (2) 200 and (1) 100A CB), three ACU units (from (2) 80A and (1) 35A CB) and softball field lighting (from 150A CB). Panels B2 and B3, located in the north electrical room, serve the north part of the building. Panel B1, located in the janitor closet, serves the south part of the building. All panels are by Cutler-Hammer, built 04/96, PRL3A and PRL1 type. This building is protected by a lightning protection system. The utility meter is located at the south exterior wall of the mechanical room.
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
Comments: Recorded footcandle levels include natural light contribution.
Comments: Remote head emergency light fixtures are utilized at the exterior exits, each has battery backup (Embassy, EMB-6CE 12T1, 6V Sealed Lead Acid batteries) located inside the building. The tritium gas exit signs manufactured in March 1996 have a stated life of 20 years.
High Intensity Discharge (HID)
Comments: Exterior lighting is controlled by fixture-mounted photocells. Recessed HID light fixtures are provided above the main entrance. The softball field lighting is controlled by pole-mounted key operated switch.
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
Compact Fluorescent
Classrooms
Storage Rooms
Offices
Corridors & Stairs
Toilets
Reception
Equipment Rooms (Elec/Mech)
Classrooms
Lounges
Storage Rooms
Area Recommended Level
Recorded Level Light Type
Selected Lighting w/ Battery Tritium Gas
Main Distribution Panel 120/208V, 3-Phase, 4 Wire Panelboards Receptacles, GFCI, Switches
Emergency Exit
ELECTRICAL SERVICES Number of Deficiencies = 2
Exterior Lighting1.
Interior Lighting2. Number of Deficiencies = 1
Emergency /Exit Lighting3. Number of Deficiencies = 2
Page: 10 of 65
Building: B - EDUCATION
FIRE ALARM
Comments: The fire alarm panel is a Simplex 4020 located at the reception area. The local annunciator is a Simplex 4602-8001 located in the main vestibule. The fire alarm system is additionally monitored in Reception/Security Building G.
Comments: The building is connected to the center's telephone and LAN system. Building is provided with two LAN switches (two Catalyst 3560 units).
Audible Alarm Control/Annunciator Panel Duct Smoke Detector Heat Detector Manual Pull Station Remote Annunciator Smoke Detector Visual Alarm
Connected to Main System Closed Circuit TV None TV with VCR
Telephone Security Public Address Television
GENERAL BUILDING CONDITION
Rating X Good
Fair Poor
COMMUNICATION
The facility condition is not impacting the functional use of the facility.
The facility condition IS impacting the functional use of the facility.
The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.
Electric Water Gas No YesYes
BUILDING C VOCATIONALBUILDING C - VOCATIONAL
Page: 11 of 65
Building: C - VOCATIONAL
BUILDING ENVELOPE
Foundation RoofBuilding
Concrete Loadbearing Masonry Wood / Steel
CMU Masonry EIFS
Wall Roof Batt Batt
Metal Unit - Metal Frame Storefront - Storefront Frame
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership#Floors
Business 25,140 19,065 2 Owned 1997 Unevaluated
Comments: A mezzanine with classrooms is over the vocational shops.
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
Yes
N/A
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
N/A
ACCESSIBILITY
Structural Systems1.
Exterior Walls2.
Insulation4.
Exterior Doors5. Number of Deficiencies = 3
Material Drainage Year Life
Remaining Type Area Served
EPDM
Asphalt Shingles
Interior Roof Drains
Gutters and Downspouts
Flat
Hip
Shop Area
Classrooms
3. Roof
Page: 12 of 65
Building: C - VOCATIONAL
INTERIOR FINISH
Carpet Ceramic Tile Concrete Vinyl Tile
CMU Ceramic Tile Drywall Wood Paneling
Accordion - Aluminum Frame Aluminum Storefront - Aluminum Frame
Metal Unit - Metal Frame Wood Unit - Metal Frame
VERTICAL CIRCULATION
Metal Ladder Metal Pan w/Concrete Stairs Metal Stairs
Comments: Metal stairs, some with concrete treads, provide access to shop mezzanines. There is a steel ladder to access the roof.
Fixed - Aluminum Frame; Double Glazing; Single Hung - Aluminum Frame; Double Glazing;
Acoustical Tile Exposed Structure Gypsum Board Precast Concrete Panel
Number of Deficiencies = 2
Windows6.
Floors1.
Interior Walls2.
3. Number of Deficiencies = 1
Interior Doors4. Number of Deficiencies = 6
Page: 13 of 65
Building: C - VOCATIONAL
Mechanical
Mechanical
Shop Area
Restroom
Ventilation Area Served
Packaged Direct
Expansion (Air Source)
Single Duct None Electronic Mechanical None Classrooms
Exhaust Ventilation
The classrooms and common areas served by six roof-top units (Trane #YCD120C3MOAB, 10 ton;
#YCD090D3HOBE, 165 MBH output; #YCD060C3LOBE, 5 ton; #YCD048C3LOBE, 4 ton;
#YCD036C3LOBE, 3 ton, all built between 1/1996 and 5/1996; and #YCD030F1NOBJ, 2-1/2 ton, built 4/2005) half with mechanical outdoor intake.
Comments:
Number of Deficiencies = 1
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
The classrooms and common areas served by six roof-top units (Trane #YCD120C3MOAB, 165 MBH output; #YCD090D3HOBE, 165 MBH output; #YCD060C3LOBE, 72.9 MBH output; #YCD048C3LOBE,
72.9 MBH outout; #YCD036C3LOBE, 64.8 MBH output, all built between 1/1996 and 5/1996; and #YCD030F1NOBJ, 48 MBH output, built 4/2005) half with mechanical outdoor intake.
These are located in tool storage rooms. There are also electric wall heaters at the main entrances to the building.
There are two heating and ventilating units that serve the shop ares; one unit is manufactured by DeVilbiss (model number not available) and the other unit is manufactured by Reznor (model number not available)
Comments:
Comments:
Comments:
HVAC
Heat1.
Gas-Fired Packaged
Gas-Fired
Electric Resistance
Gas-Fired Packaged
Single Duct
Unit Heater
Unit Heater
Makeup Air Unit
None
None
None
None
Electronic
Electric
Electric
Electric
Mechanical
Natural
Natural
Mechanical
None
None
None
None
Classrooms
Shop Area
Storage
Shop Area
Ventilation2.
System Type
Number of Deficiencies = 4
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
Page: 14 of 65
Building: C - VOCATIONAL
There are two water heaters (Bradford-White #MITW50L6BN12, 48 gallon and a Lochinor #DUN051G, 50 gallon; both 32 MBH output).
Comments:
Cast Iron None None
Electric Water Cooler Fixed Emergency Eyewash Lavatory Shower/Bathtub Urinal Wall Hydrant Water Closet (Flush Valve)
Gas (Natural)
None None ABC Type Fire Extinguisher
Comments: Underground service from a pad-mounted transformer is provided to a 1200A main distribution panel with a 1200A main circuit breaker (MCB). The main panel is protected by a secondary MOV surge arrester (Joslyn Mfg., Surge Tech Z-650, 650V max). The main panel serves a 400A main-lug-only (MLO) panel (from 300A CB) located in the j-closet & serving the south wing, a 400A MCB panel (400A CB) located in the former welding/current painting shop, four 225A MCB panels ((4) 225A CB) serving each of four hard vocational shops, a two-section 225A MLO panel (200A) located in the main el. room and serving north wing, a 100A panel (100A CB) serving computer lab & a ACU5 unit (60A CB). A 400A MLO panel in the j-closet serves (4) ACU, (2) make-up air units & walkway lighting. All panels are by Cutler-Hammer, built 04/96, PRL4B and PRL1 type. The building is protected by a lightning protection system. The emergency power shut-off switches are provided in the shops. The utility meter is on the exterior.
Copper Copper Gas-Fired None No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
High Intensity Discharge (HID)
Comments: Exterior lighting is controlled by fixture-mounted photocells. Recessed HID light fixtures are provided above the main entrance. The walkway lighting is controlled by the time clock.
Main Distribution Panel 120/208V, 3-Phase, 4 Wire Panelboards Receptacles, GFCI, Switches
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING
Water Distribution1.
Sanitary Distribution2.
Fixtures3. Number of Deficiencies = 1
Fuel Distribution4.
Number of Deficiencies = 2FIRE PROTECTION
ELECTRICAL SERVICES Number of Deficiencies = 4
Exterior Lighting1.
Page: 15 of 65
Building: C - VOCATIONAL
FIRE ALARM
Comments: The fire alarm panel is a Simplex 4020 located in the manager's office. The local annunciator is a Simplex 4602-8001 located in the main vestibule area. The fire alarm system is additionally monitored in Reception/Security Building G.
Comments: The building is connected to the center's telephone and LAN system.
Audible Alarm Control/Annunciator Panel Duct Smoke Detector Heat Detector Magnetic Door Holder Manual Pull Station Remote Annunciator Smoke Detector Visual Alarm
Connected to Main System Closed Circuit TV None TV with VCR
Telephone Security Public Address Television
Comments: Recorded footcandle levels include natural light contribution.
Comments: Remote head emergency light fixtures are utilized at the exterior exits, each has battery backup (Embassy, EMB-6CE 12T1, 6V Sealed Lead Acid batteries) located inside the building. The tritium gas exit signs manufactured in March 1996 have a stated life of 20 years. Emergency light fixtures with battery backup are utilized for high ceiling areas (vocation shops).
T8 - Fluorescent
High Intensity Discharge (HID)
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
High Intensity Discharge (HID)
Classrooms
Vocational
Storage Rooms
Offices
Corridors & Stairs
Toilets
Equipment Rooms (Elec/Mech)
Vocational
Area Recommended Level
Recorded Level Light Type
Selected Lighting w/ Battery Tritium Gas
Emergency Exit
Number of Deficiencies = 1
GENERAL BUILDING CONDITION
Rating X Good
Fair Poor
Interior Lighting2. Number of Deficiencies = 3
Emergency /Exit Lighting3. Number of Deficiencies = 3
COMMUNICATION
The facility condition is not impacting the functional use of the facility.
The facility condition IS impacting the functional use of the facility.
The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.
Electric Water Gas No YesYes
BUILDING D CAFETERIA/CULINARY ARTSBUILDING D - CAFETERIA/CULINARY ARTS
Page: 16 of 65
Building: D - CAFETERIA/CULINARY ARTS
BUILDING ENVELOPE
Foundation RoofBuilding
Concrete Loadbearing Masonry Wood / Steel
CMU Masonry EIFS
Wall Roof Batt Batt
Metal Unit - Metal Frame Storefront - Storefront Frame
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership#Floors
Assembly 13,920 9,852 1 Owned 1997 Unevaluated
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
Yes
N/A
Yes
Yes
Yes
Yes
Yes
No
N/A
Yes
Yes
N/A
ACCESSIBILITY
Structural Systems1.
Exterior Walls2.
Insulation4.
Exterior Doors5. Number of Deficiencies = 3
Material Drainage Year Life
Remaining Type Area Served
EPDM
Asphalt Shingles
Interior Roof Drains
Gutters and Downspouts
Flat
Hip
Kitchen
Dining Hall
3. Roof
Page: 17 of 65
Building: D - CAFETERIA/CULINARY ARTS
INTERIOR FINISH
Carpet Ceramic Tile Concrete Quarry Tile Vinyl Tile
CMU Ceramic Tile Plaster
Aluminum Storefront - Aluminum Frame Metal Unit - Metal Frame
Wood Unit - Metal Frame
VERTICAL CIRCULATION
Concrete Stairs Metal Ladder
Comments: Concrete stairs are from grade to the loading dock. There is a steel ladder to access the roof.
Fixed - Aluminum Frame; Double Glazing; Single Hung - Aluminum Frame; Double Glazing;
Acoustical Tile Gypsum Board
Number of Deficiencies = 3
Windows6.
Floors1.
Interior Walls2.
3.
Interior Doors4. Number of Deficiencies = 6
Page: 18 of 65
Building: D - CAFETERIA/CULINARY ARTS
Mechanical
Mechanical
Mechanical
Restroom
Kitchen
Janitor's Closet
Comments: All kitchen exhaust hoods are ventilated by roof fans (main kitchen hoods by Acme #PNU365GGP; the servery area hood by Acme #PNU245RGM and the Culinary Arts hood by an undetermined Acme model). The dishwashers are also ventilated.
Ventilation Area ServedExhaust Ventilation
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
This is a roof-mounted unit (Trane #YCD210C3L0AB, 203 MBH output, 7000 CFM, built 8/1996).
This is a roof-mounted unit (Trane #YCD180B3LDEA, 203 MBH output, 6000 CFM, built 4/2000) serving the main kitchen.
This is a roof-mounted unit (Trane #YCD120, 96 MBH output, 4000 CFM, built 8/1996) serving the Culinary Arts kitchen space.
This is a roof-mounted unit (Trane #GRCA35GDMBON, 276 MBH output, 3420 CFM @ 1" wg, built 8/1996) serving the Dining Hall servery exhaust hood.
This is a roof-mounted unit (Trane #GRAA60GDNBON, 480 MBH output, 7600 CFM, built 8/1996) serving the kitchen food preparation area exhaust hoods.
This a roof-mounted unit (Trane #GRAA40GDMBON,320 MBH output, 6000 CFM, built 8/1996) serving the Culinary Arts kitchen exhaust hood.
There is an electric wall heater at the front entrance vestibule.
Comments:
Comments:
Comments:
Comments:
Comments:
Comments:
Comments:
HVAC
Heat1.
Gas-Fired Packaged
Gas-Fired Packaged
Gas-Fired Packaged
Gas-Fired Furnace
Gas-Fired Furnace
Gas-Fired Furnace
Electric Resistance
Single Duct
Single Duct
Single Duct
Makeup Air Unit
Makeup Air Unit
Makeup Air Unit
Unit Heater
None
None
None
None
None
None
None
Electronic
Electronic
Electronic
Electronic
Electronic
Electronic
Electric
Mechanical
Mechanical
Mechanical
Mechanical
Mechanical
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .