This file contains a product specification sheet for a Hobart CLPS66eN-BAS electric high-temperature rack conveyor dishwashing machine and a related Georgia state and local contract opportunity for food service equipment contracting services. The contract opportunity requires a Food Service Equipment Contractor (FSEC) to deliver, install, and commission a new dish machine, with the recommended installer being Sam Service. The scope of work includes disconnecting and removing the existing dish machine and booster heater, modifying the existing clean table and overhead shelves to accommodate a side loader model (SL 30), fabricating and installing new ductwork from the machine to the existing overhead duct system, capping the existing 30-amp disconnect, and making all final electrical and operational connections using the existing booster heater disconnect with single-point connection capability. The contractor is required to conduct a site visit to assess space availability, utility compatibility, and work requirements, and must provide equipment demonstration and operational training upon completion.
The Hobart CLPS66eN-BAS specifications indicate a capacity of 202 racks per hour with a 23-gallon wash tank and power scrapper, standard features including a 22-inch power scrapper, Opti-Rinse system, configurable intelligent de-lime notification, top-mounted microprocessor controls, and NSF-approved pot and pan cycle mode. The machine accommodates up to six standard sheet pans in a 19.5-inch chamber height opening and includes energy-saver mode with programmable auto-shutdown. The unit requires specific electrical connections with options for single or dual-point connections at various voltages (208/60/3, 240/60/3, 480/60/3, and 600/60/3), an internal optional 30-kilowatt electric booster heater (convertible to 15 kilowatts with 140-degree Fahrenheit incoming water), minimum incoming water temperatures of 110 to 180 degrees Fahrenheit depending on booster configuration, and water consumption of approximately 126 gallons per hour at maximum use. The machine ships at approximately 855 pounds and requires minimum venting loads of 200 CFM at the load end and 400 CFM at the unload end. Optional accessories include various vent hood configurations, direct drive unloader, side loader units, blower-dryer, and drain water tempering kits.
Text of this file
Approved by______________________________________ Date___________ Approved by______________________________________ Date___________
CLPS66eN-BAS ELECTRIC High Temperature Rack Conveyor Dishwashing Machine
Printed in U.S.A. HOBART • 701 S Ridge Avenue, Troy, OH 45373 • 1-888-4HOBART • www.hobartcorp.com F40636 (03/21) Page 1 of 4
CLeN SERIES – CLPS66eN-BAS ELECTRIC
COM
M
ERCIAL
DISHW
ASHERS
Project_____________________________________________________________________
AIA #_________________________________ SIS #_________________________________
Item #________________________________ Quantity_________ C.S.I. Section 114000
SPECIFIER STATEMENT
Specified dishwasher will be Hobart CLPS66eN Base electric tank heat model with Opti-Rinse™.
Includes 22" power scrapper, insulated ergonomic cabinet style doors, dirty water indicator, con-figurable “intelligent” de-lime notification, top mounted computer controls, and NSF approved pot and pan cycle mode. The wash tank utilizes durable precision pressure sensor monitors in lieu of conventional mechanical floats. The 19.5" standard chamber height will accommodate up to (6) standard sheet pans at a time on an open-end sheet pan rack.
STANDARD FEATURES
| + 202 racks per hour |
| + 22" power scrapper |
| + Opti-Rinse™ system |
| + Rapid return conveyor drive mechanism |
| + Large double door opening for ease of cleaning |
| + Doors are insulated & hinged with door interlock switches |
| + 19.5" chamber height opening (accepts sheet pans) |
| + Top mounted micro-processor control module |
| + Energy saver mode (programmable auto-shut down) |
| + Dirty water indicator |
| + Manager activated low temperature alert |
| + NSF rated configurable pot and pan dwell mode |
| + Configurable “intelligent” delime notification |
| + Service diagnostics |
| + Self-aligning wash manifolds |
| + Stainless steel anti-clogging wash arms |
| + Stainless steel self-draining pump and impeller |
| + Single, sloping scrap screen and deep scrap basket |
| + Stainless panels enclose perimeter and bottom |
| + Door actuated drain closure |
| + Convertible hot water or low temp final rinse |
| + Vent fan control |
| + Booster heater control |
| + Power scrapper vent cowl curtain kit |
| + ENERGY STAR® Certified |
OPTIONS & ACCESSORIES (Available at extra cost)
| ❑ Standard, short, and extended stainless steel vent hoods |
| ❑ Internal stainless steel pressure-less 30 kW booster heater |
field convertible to 15 kW (booster includes PRV) + Dual point electrical connection standard on 208/60/3 and 240/60/3 voltage machines, when equipped with internal booster; single point kits available (see page 3)
+ Single point connection standard on 480/60/3 and 600/60/3 voltage machines, when equipped with internal booster
❑ Direct drive unloader – adds 38" length. Reference spec F39520 for more details
❑ Side loader – SL23 adds 23" length, SL30 adds 30" length.
Reference specs F40926 and F40927 for more details
❑ Blower-dryer – adds 331⁄4" to length. Reference spec F40252 for more details (ships separate from dishmachine, contact Hobart Service for installation)
| ❑ Drain water tempering kit (field installed) |
| ❑ Flanged feet kit (requires two kits) |
| ❑ Higher than standard chamber (24" opening) |
| ❑ Table limit switch with 10' wire |
| ❑ Correctional package (contact Hobart for details) |
| ❑ Pressure regulator valve (PRV), for use with external booster |
| ❑ Water shock absorber kit |
| ❑ Factory-mounted circuit breakers (contact Hobart for details) |
| ❑ Field installed single point kits available for 208/60/3 and |
240/60/3 machines when equipped with internal booster
Page 2 of 4 CLPS66eN-BAS ELECTRIC
High Temperature Rack Conveyor
Dishwashing Machine
CAD and/or Revit Files Available
P3
V1
L-R OPER
7 3/8
65 1/2"10"
TYP
5"
68 1/2"
21 5/8"
V1
R-L OPER
68 1/2"
7 3/8
65 1/2"10"
TYP
5" 21 5/8"
20" SERVICE
CLEARANCE
(BOTH SIDES)
23"
OPEN DOOR
CLEARANCE
29 1/2"
62 1/2"
47 13/16" 55 1/2"
62 9/32" P2 E2 E1
P2 E1 E2
23"
OPEN DOOR
CLEARANCE
20" SERVICE
CLEARANCE
(BOTH SIDES)
32 3/4" 41 15/32"
62 13/64"
62 1/2"
22"
BOTH ENDS
19 11/16"
31 1/16"
7 3/8"
5" RECOMMENDED
MIN. DISTANCE
FROM WALL13"
WALL
WIDTH OF
TRACKS
WIDTH OF
MACHINE 20" 27"
11"
27"
AVG INSIDE
TABLE WIDTH
14 1/2"
CL
MACHINE 2 HOLES FOR BOLTING
TABLE TO TANK
FRONT OF
MACHINE
CL
3/8"
3/8"
3"
1 1/4"
8" AVG
22"
INSIDE TANK
3"
65 9/16" 65 9/16"
P3 P3 36 7/8"
P1P1
34"
E3 E3
E3E1 E2
63 3/4"
Top View Left to Right Top View Right to Left
Front View Left to Right Front View Right to Left
Side View
MODEL:
CLPS66eN BASE
L-R OPERATION
D-974807
REV B
MODEL:
CLPS66eN BASE
R-L OPERATION
D-974806
REV B
Suggested Track and Table Layout
View Showing Hole Locations in Turned Down Portion of Table
Tabling Connection: 66" inside tank (at table connection) http://hobart.kclcad.com/mobile
High Temperature Rack Conveyor
Dishwashing Machine
CLPS66eN-BAS ELECTRIC Page 3 of 4
SPECIFICATIONS
Capacities
| Racks per Hour (NSF rated). . . . . . . . . . . . . . . . . . . . . . . . . . . . 202 |
| Wash Tank (U.S. gallons). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 |
| Power Scrapper (U.S. gallons). . . . . . . . . . . . . . . . . . . . . . . . . . . 23 |
| Conveyor Speed (feet per minute). . . . . . . . . . . . . . . . . . . . . . . . 5.6 |
Motor Horsepower
| Drive. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/6 |
| Wash. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 |
| Power Scrapper. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 |
Water Consumption
| U.S. Gallons per Hour (maximum use at 20 PSI). . . . . . . . . . . . 126 |
| U.S. Gallons per Rack. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.62 |
| Peak Drain Flow (U.S. gallons per minute). . . . . . . . . . . . . . . . . . 38 |
Heating
| Tank Heat, Electric (kW) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 |
| Optional Electric Booster (built-in) (kW for 40°F rise). . . . . . . . 15 |
| Optional Electric Booster (built-in) (kW for 70°F rise). . . . . . . . 30 |
Venting
| Load End (minimum CFM). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 |
| Unload End (minimum CFM). . . . . . . . . . . . . . . . . . . . . . . . . . . . 400 |
Shipping Weight (approximate). . . . . . . . . . . . . . . . . . . . . . . 855 lbs.
Crated Dimensions. . . . . . . . . . . . . . . . . . . . . . . 76"L x 38"W x 78"H
LEGEND
Electrical Connections
Required when machine equipped with
SINGLE POINT ELECTRICAL CONNECTION
E1 Tank heat, motors, controls AND 30kW booster heater – multiple knockouts provided, 63-3/4" AFF.
Required when machine equipped with
DUAL POINT ELECTRICAL CONNECTION
E2 Tank heat, motors and controls – multiple knockouts provided, 63-3/4" AFF.
E3 Internal 30kW booster heater – multiple knockouts provided, 63-3/4" AFF.
Multiple knockouts provided for 2", 1" and 1/2" trade size conduits.
Plumbing Connections
P1
Drain. May be drained to either side of valve, plug opposite side 2" FPT. Recommend a floor drain minimum of 12'' from machine for access and maintenance. 7-3/8" AFF.
P2 Hot water. 1/2" FPT connection. 1/2", 11-3/16" AFF.
See plumbing notes for required temperatures.
P3 Optional cold water connection for drain water tempering 1/2" FPT, cold water temperature 80°F, maximum 7-3/8" AFF.
Vent Connections
V1 Optional vent hoods, 4" x 16" vent stack with damper.
E1 Single Point Electrical Connection with internal 30 kW Booster Heater
Voltage
(E1) Tank Heat, Motors, Controls 30kW Booster Heater
Single Point Service Connection Rated Amps
Minimum Supply Circuit Ampacity / Maximum Protective Device
208/60/3 144.5 175 Field Installed SGLPT-KIT4-CLE required, order separately 240/60/3 138.2 150 Field Installed SGLPT-KIT2-CLE required, order separately 480/60/3 70.7 90 Ships Standard, Factory Installed 600/60/3 49.4 60 Ships Standard, Factory Installed
E2 Dual Point Electrical Connection with Internal 30 kW Booster Heater (For machines without internal booster heater, refer to E2, Tank Heat, Motors & Controls connection only)E3
Voltage
(E2) Tank Heat, Motors, Controls (E3) 30kW Booster Heater
Dual Point Service ConnectionRated Amps
Minimum Supply Circuit Ampacity / Maximum
Protective Device Rated Amps
Minimum Supply Circuit Ampacity / Maximum
Protective Device 208/60/3 60.6 80 83.9 90 Dual Point Ships Standard 240/60/3 58.0 80 80.2 90 Dual Point Ships Standard 480/60/3 30.6 40 40.1 50 Field Convertible 600/60/3 22.6 35 26.9 40 Field Convertible
High Temperature Rack Conveyor
Dishwashing Machine
As continued product improvement is a policy of Hobart, specifications are subject to change without notice.
F40636 (03/21) Page 4 of 4 HOBART • 701 S Ridge Avenue, Troy, OH 45373 • 1-888-4HOBART • www.hobartcorp.com Printed in U.S.A.
VENT HOOD OPTIONS (Adjustable, vent stack can be adjusted 1" to either side)
Standard Short Extended
4 3/4"
OUTSIDE
11 1/4"
OUTSIDE
REF
10" 10"
4 3/4"
OUTSIDE
5 3/4"
OUTSIDE
REF
10"
4 3/4"
OUTSIDE
20 1/2"
OUTSIDE
REF
CLPS66eN-BAS Electric Heat Dissipation
Booster
BTU/HR.
Latent Sensible Without Booster 15,800 6,800
15kW Booster 29,300 12,600 30kW Booster 42,900 18,400
NOTE: 30kW Booster Heater field convertible to 15kW when 140°F incoming water provided.
(Conversion instructions located in machine control box. Contact factory for 15kW booster amperage ratings.)
NOTE: Additional CLeN Voltages and Amperages are available, see document F40972.
WARNING: Plumbing and electrical connections should be made by qualified personnel who will observe all the applicable plumbing, sanitary, safety codes and National Electrical Code.
Plumbing Notes: Minimum incoming water temperatures: 110°F for 30kW internal booster, 140°F for 15kW field converted internal booster, 180°F without internal booster. Building flowing water pressure to dish machine is 20 PSI, (+/- 5 PSI). For non-booster machines, a PRV with internal expansion bypass is required.
When ordered as an accessory, 1⁄2" brass regulator must be installed before the booster. Water temperature to the regulator must not exceed 140°F.
Recommended water hardness to be 3 grains or less for best results.
Electrical Note: Dishmachine not provided with internal GFCI protection.