DIG PERMIT 04192023.pdf
PDF 149 KB Posted
- Attached to
- HAFB Fencing
- Solicitation number
- FA8201-25-R-FENCING-HAFB
About this file
This document is a Dig Permit form for excavation work, specifically related to the HAFB Fencing project at Hill Air Force Base. The permit outlines critical safety and operational requirements for excavation, including mandatory utility marking procedures, with specific instructions for working near utilities. Key requirements include field marking excavation alignments with flags or non-permanent white paint, maintaining Red Stakes markings, and obtaining proper notifications before beginning work. The permit emphasizes safety protocols, such as mandatory hydro-vac or hand digging within 3 feet of utilities, immediate work stoppage in case of line strikes, and emergency contact procedures.
The permit is part of a broader Sources Sought Notice for a fencing services contract (Solicitation Number: FA8201-25-R-FENCING-HAFB) issued by the Department of the Air Force Materiel Command Air Force Sustainment Center. The contract is an Indefinite-Delivery Indefinite-Quantity (IDIQ) for maintenance, repair, and minor construction fence projects at Hill Air Force Base, Little Mountain Test Annex, and Utah Test and Training Range. The estimated maximum contract value is $4,000,000, with individual task orders ranging from $2,500 to $4,000,000, and a total performance period of 5 years and 6 months. The procurement is targeted at small businesses, including 8(a), Service-Disabled Veteran-Owned, HUBZone, and Women-Owned Small Business concerns.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| SOURCES SOUGHT NOTICE_07Mar2025.pdf | ||
| Statement of Work - Fencing 25 Feb 2025.pdf | ||
| NEW Safety 20181031_ APPENDIX C.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
4.EMERGENCY URGENT ROUTINE
Yes No
- The Project Manager or Responsible Party shall field mark the alignment of all intended excavations with flags or non-permanent white paint.
-The Project Manager and/or Contractor must maintain the Red Stakes markings.
- The project manager or responsible party will notify the contractor when the permit is complete and excavation can begin.
RESPONSIBILITY STATEMENT: The responsible individual's signature (Item # 9) indicates that they understand their responsibilities regarding maps and utility markings. If the responsible individual is a contractor, their signature denotes acceptance of all financial and other responsibilities as it relates to any damage to utilities and personnel as identified by the Red Stake office. It is further understood that in the event of a line strike, however minor, work will immediately stop, the site will be cleared of personnel, and
Customer Service will be immediately notified. (777-1856)
*HYDRA VAC or HAND DIGGING IS REQUIRED WITHIN A MINIMUM OF 3 FEET OF ALL UTILITIES!!
**PLEASE REMOVE ALL MARKINGS AFTER WORK IS COMPLETE.
GENERAL
INFORMATION ENTITY PHONE DATE
BASE CIVIL ENGINEERING EXCAVATION PERMIT
6. WORK LOCATION OR AREA:
PRINT NAME SIGN NAME
3. JO# / WO#/ CONTRACT PROJECT:2. PROJECT MANAGER OR CE REQUESTER NAME AND PHONE:
***This permit is required to be on hand, on site, during ANY excavation.*** All utility markings are valid for 30 Days
PERMIT VALID UNTIL:
PERMIT NUMBER #:
IN CASE OF EMERGENCY PLEASE CALL 777-1856
7. WORK DESCRIPTION: 8: COMPANY NAME & PHONE:
9. COMPANY REPRESENTATIVE:
1. DATE SUBMITTED
(ALLOW 14 DAYS)
5. SITE VISIT REQUESTED:
SIGNATURE OF
LOCATER
Storm drain, low voltage, gas, Industrial Waste, Environmental
801-695-9785
RED STAKE 777-0540
All excavation work within a 15 ft radius of high pressure natural gas distribution lines requires Questar Gas technicians to be on-site during the dig, this will be coordinated through Blue Stake.
BLUE STAKE
Blue Stakes Permit #___________________________
AMERICAN WATER
SERVICE
CITY LIGHT & POWER
GROUNDS QA
Water & Sewer
High Voltage
Ground Sprinklers/Irrigation
801-660-2255
775-4133
COMM 801-586-8903 For all COMM
Blue Stake permit needed?
CALL 3 DAYS AHEAD
75 CEG/CEOER FORM 12, 19 April 2022
YES NO
RED GREEN
ORANGE BLUE
YELLOW WHITE
PURPLE PINK
Were all records properly filed?
12. ADDITIONAL REMARKS (PRECAUTIONARY MEASURES TO BE TAKEN)
Certifying Technician's Checklist:
Post approval:
Was a periodic inspection made? ________ Dates:_________________
Were markings accurate? _________
Was labor charged?
75 CEG/CEOER FORM 12, 19 April 2022
UTILITY COLOR CODES
ELECTRIC POWER LINES, POWERED CONDUITS STORM & SANITARYSEWERS, DRAIN LINES
Was the CE requestor/Alternate contacted upon completion of request.
11. RED STAKE CHECKLIST:
Is the information for sections 1-10/12 properly filled out by an appropriate government representative?
Prior to approval:
Make appropriate entries to Red Stake log and file copies.
RECLAIMED WATER & IRRIGAION TEMPORARY SURVEY MARKER
10. All Subsurface utilities installed shall use tracer wire as specified in the Hill Air Force Base Design Standard. Utility shall be defined as, but not limited to: electric systems; storm, sanitary and subsurface drainage systems including French drains, rain gutter collection and distribution systems, and other water collection systems; potable and non-potable water systems; natural gas systems; industrial waste systems;
fuel systems; communication systems; street lighting systems; heating and cooling systems; airfield associated systems; environmental systems; other objects designed for future use such as burried conduits and pipes; and other comparable items, objects or systems. The determination and definition of a utility requiring tracer wire shall be at the sole discretion of the United States Air Force.
COMM LINES, CABLES, & UNKNOWS POTABLE WATERM, IRRIGATION & SLURRY LINES
GAS, OIL, PETROL & OTHER GASEOUS MATERIALS DIGGING SITE BOUNDARIES TRENCH LINES
Has the site been properly marked to indicate area to be excavated?
Has a visual inspection of the area requiring locate been performed. Has the obvious been identified?
Was the area properly scanned utilizing all available equipment and resources? Locator/Ground Radar etc..
Were utility color codes properly used when identifying utilities?
DATE: __________________________ Individual receiving information:_________________________________________________________________
IN CASE OF EMERGENCY PLEASE CALL 777-1856
Has appropriate research been accomplished prior to site investigation? GIS map and G Tabs etc..
13. Extensions :
Permit Extension Valid Until
Redstake Authorized Signature ( P e r m i t e x t e n s i o n o n l y v a l i d w i t h a u t h o r i z e d s i g n a t u r e . )
Sheet1
| 1 DATE SUBMITTED ALLOW 14 DAYS: |
| 2 PROJECT MANAGER OR CE REQUESTER NAME AND PHONE: |
| 3 JO WO CONTRACT PROJECT: |
| 6 WORK LOCATION OR AREA: |
| 7 WORK DESCRIPTION: |
| 8 COMPANY NAME PHONE: |
| PRINT NAME: |
| DATEStorm drain low voltage gas Industrial Waste Environmental: |
| DATEFor all COMM: |
| DATEWater Sewer: |
| DATEHigh Voltage: |
| DATEGround SprinklersIrrigation: |
| DATECALL 3 DAYS AHEAD: |
| Blue Stakes Permit: |
| Dates: |
| 12 ADDITIONAL REMARKS PRECAUTIONARY MEASURES TO BE TAKEN: |
| DATE: |
| Individual receiving information: |
| Text1: |
| Text2: |
| Check Box4: Off |
| Check Box5: Off |
| Group6: Choice3 |
| Check Box7: Off |
| Check Box8: Off |
| Check Box21: Off |
| Check Box22: Off |
| Initial 2: |
| Initial: |
| Check Box23: Off |
| Check Box24: Off |
| Check Box25: Off |
| Dropdown26: [Yes] |
| Dropdown27: [Yes] |
| Extension Date: |