DeWitt HW Bleachers - Drawings.pdf

PDF 580 KB Posted

Attached to
See attached documents for all RFP information.
Solicitation number
RFP-DEW-170000000013-1
Issued by
Clinton County, Detroit City, Michigan

About this file

This architectural drawing set from GMB Architecture + Engineering details construction plans for Bid Pack 2 at Herbison Woods School in DeWitt Public Schools, Michigan. The project involves installing new power-operated telescoping bleacher systems and a gym divider with track in the existing gymnasium (Room A141). The scope includes two additive alternates: A-1 for providing graphic lettering on the Herbison Woods bleachers and A-2 for demolishing existing bleachers. The plans show detailed electrical requirements for powering the new bleacher systems, with two power supply options outlined - either connecting to existing Panel 'K' (Option 1) or Panel 'H' (Option 2).

The drawings provide comprehensive floor plans, demolition plans, and electrical specifications including panel schedules and power requirements. The new gym divider is specified as 22'-7" H x 81'-10" L (field verify) with integral wiring and controls. The electrical plans detail the power connections needed for the bleacher systems, requiring either a new 3-pole 20A circuit breaker in Panel 'K' or utilizing an existing 3-pole 20A circuit breaker in Panel 'H'. The project appears to be managed by The Skillman Corporation as Construction Manager, with drawings dated August 14, 2017 under GMB Project #5-4013.

View the file

Other files

File Type Posted
DeWitt- HW Bleachers - VOL 3.zip ZIP file
Invitation to Prime Bidders.pdf PDF
DeWitt - HW Bleachers - VOL 4.pdf PDF
DeWitt- HW Bleachers - VOL 1.pdf PDF
DeWitt- HW Bleachers - VOL 2.zip ZIP file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GMB

ARCHITECT + ENGINEER

ARCHITECTURE + ENGINEERING

85 East Eighth Street, Suite 200, Holland, MI 49423 P. 616.796.0200 F. 616.796.0201 www.gmb.com

OWNER

GMB Project #

Printed On Recycled Paper

THE SKILLMAN CORPORATION

CONSTRUCTION MANAGER

8120 Moorsbridge Rd. Portage, MI. 49024 P. 269.350.5757 www.skillman.com

VICINITY MAP

ALTERNATES

DEWITT PUBLIC SCHOOLS

2957 W. Herbison Rd. DeWitt, MI. 48820 P. 517.668.3430 www.dewittschools.net

MAP BY GOOGLE

C :\L oc al

P ro je ct s\ 5-

A

_C

EN

TR

AL

_R an dy

Z.

rv t

DEWITT PUBLIC SCHOOLS

DEWITT, MICHIGAN

BID PACK 2

5-4013

HERBISON WOODS SCHOOL

ARCHITECTURAL

2A2.1A BID PACK 2 - UNIT 'A' GYM BLEACHER & GYM DIVIDER

ADDITIVE ALTERNATE A-1:

PROVIDE GRAPHIC LETTERING ON HERBISON WOODS BLEACHERS

ADDITIVE ALTERNATE A-2:

DEMOLISH EXISTING BLEACHERS AT HERBISON WOODS

ELECTRICAL

2E1.1A BID PACK 2 - UNIT 'A' ELECTRICAL PLANS

08.14.2017

BID PACK 2

BF

UPUP

4s 2s

3s 2s

4s

9s23 s

4s 2s

3s 2s

4s

9s23 s

UNIT 'A'

UNIT 'C'

UN

IT

'A

UN

IT

'B

EX. GYMNASIUM

A141

EX. STAIR

AS02

EX. STORAGE

A140

EX. DRY STORAGE

A143

EX. TRAINING

A138

EX. OFFICE

A137

EX. PASSAGE

A139

EX. TEAM LOCKERS

A132

EX. SHOWER

A136

EX. TOILET

A134

EX. DRYING

A133

EX. PASSAGE

A135

EX. PASSAGE

A128

EX. OFFICE

A130

EX. STORAGE

A129

EX. TOILET

A131

EX. PASSAGE

A125

EX. BASKETS

A126

EX. BOY'S LOCKER ROOM

A127

EX. LAUNDRY

A123

EX. PASSAGE

A122EX. STORAGE

A124

EX. TOILET

A121

EX. SHOWER

A120

EX. OFFICE

A119

EX. STAIR

AS01

EX. STORAGE

A144

BOY'S TOILET

A114

GIRL'S TOILET

A113

EX. GIRL'S LOCKER ROOM

A117

EX. PASSAGE

A118

EX. BASKETS

A116

EX. PASSAGE

A115

EX. VESTIBULE

A101

EX. CORRIDOR

A102

MULTI-PURPOSE ROOM

A107

STORAGE

A112

STORAGE

A111

STORAGE

A110

STORAGE

A109

STORAGE

A108

EX. STORAGE

A104

EX. OFFICE

A105

EX. BREAK OUT

A106

EX. CHOIR

A103

EX. OFF

B127

EX. ROOM

B128

EX. STORAGE

B126

EX. ELECTRICAL

B125

EX. VESTIBULE

C101

EX. LOBBY

C102

EX. CORRIDOR

C107

EX. PASSAGE

C109

EX. GYMNASIUM

A141

8"

8"

8" 4'

- 0

20' - 6 11/16"

NEW GYM DIVIDER & TRACK

22'-7" H x 81'- 10" L (FIELD VERIFY)

A4.01

A4.01 2

A4.03

LOCATION OF EXISTING

GRAPHIC (FIELD VERIFY)

GENERAL FLOOR PLAN NOTES:

1. DIMENSIONS GIVEN ARE TO THE FACE OF MASONRY UNITS OR TO THE FINISHED FACE OF METAL STUD PARTITION WALLS.

2. REFERENCE STRUCTURAL DRAWINGS FOR CONCRETE SLAB SIZES AND SLAB RELATED INFORMATION

3. INTERIOR STUD WALLS ARE TO USE 3.5/8" METAL STUD FRAMING UNLESS OTHERWISE NOTED

4. TURN UP VAPOR RETARDER MATERIAL AT JOINTS BETWEEN FLOOR SLAB AND FOUNDATION WALL UNLESS NOTED OTHERWISE

5. SEE FOUNDATION PLANS FOR FLOOR SLAB RECESSES FOR TILE, WOOD FLOOR, ETC. (VERIFY RECESS REQUIRED BY MFGR.)

6. EXTEND ALL INTERIOR WALL PARTITIONS (MASONRY OR STUDS) TO BOTTOM OF DECK ABOVE UNLESS NOTED OTHERWISE.

7. REFERENCE STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL FOR ITEMS NOT SHOWN. COORDINATE AS REQUIRED

INCLUDING NECESSARY FRAMING, BLOCKING ETC.

8. FIELD VERIFY ALL DIMENSIONS PRIOR TO FABRICATION OF ANY CABINETRY, FRAMES, STRUCTURAL ITEMS, ETC.

9. PROVIDE PAINTED ACCESS PANELS IN WALLS AND CEILINGS TO PROVIDE ACCESS TO CONCEALED ITEMS INCLUDING BUT NOT LIMITED TO VALVES, CONTROLS, MECH. EQUIPMENT ETC. ACCESS PANELS MAY NOT ALWAYS BE SHOWN ON PLANS. IT IS THE SUB CONTRACTOR RESPONSIBILITY TO DETERMINE LOCATIONS. COORDINATE LOCATIONS WITH OTHER GENERAL

CONTRACTOR / SITE SUPERVISOR

10. COORDINATE WALLS WITH COLUMNS AND OTHER ENCASED ITEMS. COLUMNS ARE TO BE CONTAINED WITHIN WALLS. THE FRAMING CONTRACTOR SHALL INCREASE FRAMING SIZE TO ACCOMIDATE COLUMNS, DRAIN LEADERS, PIPING, ELECTRICAL PANELS ETC. WHERE WALLS REQUIRE EXTRA WIDTH THE ENTIRE WALL SHALL BE WIDENED UNLESS APPROVED BY

ARCHITECT.

11. ALL GUARDRAILS AND HANDRAILS SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH ALL REQUIREMENTS OF THE 2012 M.B.C. , ANSI ICC A117.1-2009 & AMERICANS WITH DISABILITIES ACT GUIDELINES. THE MOST STRINGENT SHALL PREVAIL.

12. PROVIDE MINIMUM CLEARANCES AT ALL DOORS PER DETAILS. SEE G1.01 FOR REQUIREMENTS

13. FOR ALL CABINETRY SEE INTERIOR ELEVATIONS FOR LAYOUTS. FIELD VERIFY CLEAR WIDTHS PRIOR TO FABRICATION

14. ALL EXTERIOR BLOCK CORNERS ARE TO BE BULLNOSE BLOCK EXCEPT CONCRETE BLOCK COLUMNS, PIERS AND WALLS TO

RECIEVE TILE - UNLESS NOTED OTHERWISE.

15. CONTRACTOR TO MAINTAIN / REPAIR RATING OF EXISTING PARTITIONS AS AFFECTED BY DEMOLITION / NEW CONSTRUCTION.

TYPICAL THROUGHOUT

16. SEAL ALL PENETRATIONS IN FIRE RATED FLOORS AND WALLS WITH APPROVED FIRESTOPPING.

17. WHERE SPECIALTY BLOCK IS REQUIRED AT THE SAME HEIGHT ON BOTH SIDES OF A WALL USE (2) SPECIALTY BLOCKS BACK TO BACK TO MAINTAIN THE FINISHED WALL APPEARANCE BOTH SIDES OF THE WALL. COORDINATE WITH STRUCTURE FOR

LINTELS CONDITIONS PER SPECIFICATIONS

18. SEE STRUCTURAL FRAMING PLANS FOR ADDITIONAL WALL REINFORCING REQUIREMENTS. MINIMUM REINFORCING (FOR ALL

WALLS NOT OTHERWISE NOTED ON STRUCTURAL PLANS) :

A. ALL BEARING WALLS SHALL RECEIVE A MINIMUM REINFORCING OF R1-5-48.

B. ALL EXTERIOR WALLS SHALL RECEIVE A MINIMUM REINFORCING OF R1-5-48.

C. ALL INTERIOR NON-BEARING WALLS OVER 16'-0" HIGH SHALL RECEIVE AMINIMUM REINFORCING OF R1-5-48.

WALL LEGEND

5/8" GYP. BOARD BOTH SIDES 3 5/8" LIGHT GA.

METAL FRAMING AT 16" O.C. SOUND BATT

FULL HEIGHT OF WALL. WALLS TO BOTTOM

OF DECK UNLESS NOTED OTHERWISE

CMU WALL SEE FLOOR PLANS FOR REQUIRED

WALL REINFORCING. NOMINAL DIMENSIONS

GIVEN

(8" TYPICAL U.N.O.)

5/8" GYP. BOARD BOTH SIDES 6" LIGHT GA.

METAL FRAMING AT 16" O.C. SOUND BATT

FULL HEIGHT OF WALL. WALLS TO BOTTOM

OF DECK UNLESS NOTED OTHERWISE

-FIRE RATINGS AS CALLED FOR ON CODE COMPLIANCE PLAN

-DIMENSIONS GIVEN ARE TO THE FINISHED FACE OF CMU OR

GYPSUM WALL BOARD UNLESS NOTED OTHERWISE

BRICK AND CMU WALL W/ 2" SPRAY APPLIED

INSULATION SEE FLOOR PLANS FOR REQUIRED

WALL REINFORCING. NOMINAL DIMENSIONS

GIVEN. SEE WALL SECTIONS FOR ADDITIONAL

DETAILS, BANDING, ETC.

(3 5/8" BRICK & 8" CMU TYPICAL U.N.O.)

CONCRETE WALL SEE STRUCTURAL

PLANS FOR REQUIRED REINFORCING.

4 7 /8"

7 1 /4"

SE

E

PL

AN

SE

E

PL

AN

SE

E

PL

AN

PROJECT NO.

DRAWN

REVIEWED

GMB

No part of this drawing may be used or reproduced in any form or by any means, or stored in a database or retrieval system, without prior written permission of

Copyright 2017 All Rights Reservedc

ARCHITECTURE + ENGINEERING

85 East Eighth Street, Suite 200

P. 616.796.0200 F. 616.796.0201

HOLLAND LAB

www.gmb.com

Holland, Michigan 49423

2025 East Beltline SE, Suite 308

GRAND RAPIDS LAB

Grand Rapids, Michigan 49546

310 North Alabama Street, Suite 230

INDIANAPOLIS LAB

Indianapolis, IN 46204

H E

R B

IS

O

N W

O O

D S

S C

H O

O L

B

ID

P A

C K

C :\L oc al

P ro je ct s\ 5-

A

_C

EN

TR

AL

_R an dy

Z.

rv t

8/

/2

7:

:0

AM

2A2.1A

5-4013

BID PACK 2 - UNIT 'A' GYM

BLEACHER & DIVIDER

Author Approver

D E

W

IT

T P

U B

LI

C

S C

H O

O

LS

D E

W

IT

T, M

IC

H

IG

A

N

NO

RT

H

1/8" = 1'-0"

BID PACK 2 - UNIT 'A' GYM BLEACHERS & DIVIDER

08.14.2017 BID PACK 2

B F

B F

1/2

1/2

1/2

1/2 s s s s s s s s s s s s s s

EX. STORAGE

A144

EX. OFFICE

A119

EX. PASSAGE

A122

EX. STORAGE

A124

EX. LAUNDRY

A123

EX. PASSAGE

A135

EX. OFFICE

A137

EX. DRY STORAGE

A143

EX. TRAINING

A138

EX. STORAGE

A140

EX. STORAGE

C106

EX. STORAGE

C108

EX. STORAGE

A129

EX. OFFICE

A130

EX. TOILET

A131

EX. STAIR

AS02

EX. STAIR

AS01

EX. GYMNASIUM

A141

EX. TOILET

A121

EX. PASSAGE

A115

EX. BASKETS

A116

EX. CORRIDOR

A102

EX. BOY'S LOCKER ROOM

A127

EX. TOILET

A134

EX. SHOWER

A136

EX. TEAM LOCKERS

A132

EX. PASSAGE

A125

EX. BASKETS

A126

EX. SHOWER

A120

EX. PASSAGE

A118

EX. GIRL'S LOCKER ROOM

A117

EX. VESTIBULE

C101

EX. PASSAGE

A139

EX. PASSAGE

A128

GIRL'S TOILET

A113

BOY'S TOILET

A114

EX. VESTIBULE

A101

EX. LOBBY

C102

EX. DRYING

A133

EX. PANEL 'K'

NEW POWER-OPERATED TELESCOPING

BLEACHER SYSTEM PER SECTION 12 66 13

EX. POWER/COMM.

SURFACE RACEWAY

TO REMAIN

EX. PANEL 'H'

EX. PANEL 'P'

EX. PANEL 'T'

INTEGRAL WIRING

& CONTROLS BY

SECTION 12 66 13

INTEGRAL WIRING

& CONTROLS BY

SECTION 12 66 13

NEW POWER-OPERATED TELESCOPING

BLEACHER SYSTEM PER SECTION 12 66 13

E01

E02

E03

E04

E05

E05

E06

E07E07

EX. STORAGE

A144

EX. OFFICE

A119

EX. PASSAGE

A122

EX. LAUNDRY

A123

EX. PASSAGE

A135

EX. OFFICE

A137

EX. DRY STORAGE

A143

EX. TRAINING

A138

EX. STORAGE

A140

EX. STORAGE

C106

EX. STORAGE

C108

EX. OFFICE

A130

EX. STAIR

AS02

EX. STAIR

AS01

EX. GYMNASIUM

A141

EX. TOILET

A121

EX. TOILET

A134

EX. SHOWER

A136

EX. TEAM LOCKERS

A132

EX. SHOWER

A120

EX. PASSAGE

A118

EX. GIRL'S LOCKER ROOM

A117

EX. PASSAGE

A139

EX. PASSAGE

A128

GIRL'S TOILET

A113

BOY'S TOILET

A114

EX. LOBBY

C102

EX. DRYING

A133

EX. PANEL 'H'

EX. PANEL 'K'

EX. PANEL 'T'

D05D05

D01

D01

D02D02

D02D02

D03

D04

D06

EX. WASHER

EX. EXTRACTOR

EX. DRYER

1. REMOVE ALL ITEMS SHOWN ON DEMO PLAN, UNLESS OTHERWISE NOTED. REMOVE ALL

UNUSED CONDUIT, RACEWAYS, WIRE, CABLE, CONTROLS, JUNCTION BOXES,

DISCONNECTS, MOUNTS, AND RELATED ELECTRICAL ACCESSORIES COMPLETELY BACK

TO SOURCE. REFER TO DEMOLITION SPECIFICATION.

2. MAKE PROVISIONS TO BACKFEED OR RE-CIRCUIT ANY ITEMS THAT ARE EXISTING TO

REMAIN WHICH ARE AFFECTED BY THE DEMOLITIONS.

3. THE OWNER RESERVES THE RIGHT TO SALVAGE, WHOLE OR IN PART, ANY EQUIPMENT,

SYSTEMS, AND/OR MATERIALS THAT ARE SCHEDULED FOR DEMOLITION PRIOR TO

REMOVAL FROM THE BUILDING/SITE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR

DISCONNECTION AND GATHERING OF SUCH ITEMS TO A CENTRAL LOCATION AGREED

UPON BY THE OWNER AND CONTRACTOR. ALL REMAINING EQUIPMENT AND/OR

MATERIALS REMOVED AND NOT REUSED ON THE PROJECT SHALL BECOME THE

PROPERTY OF THE CONTRACTOR AND SHALL BE REMOVED FROM THE BUILDING/SITE.

4. ALL EQUIPMENT AND/OR MATERIALS SLATED FOR REUSE SHALL BE CAREFULLY

REMOVED AND STORED TO PREVENT DAMAGE AND REINSTALLED AS WORK

PROGRESSES.

5. ALL DEMOLITION SHOWN IS GATHERED FROM FIELD OBSERVATION AND RECORD

DRAWINGS. INVESTIGATION OF EXISTING POWER AND LIGHTING SYSTEMS WILL BE

REQUIRED BY THE CONTRACTOR AS PART OF THE BID PRICE, SO THAT THE EXACT

EXTENT OF DEMOLITION CAN BE ACCURATELY DETERMINED. THE CONTRACTOR'S BID

PRICE SHALL ALSO COVER REMOVAL OF SOME PORTIONS OF POWER AND LIGHTING

SYSTEMS NOT EXPLICITLY SHOWN ON THIS DRAWING, BUT DISCOVERED DURING THE

INVESTIGATION PROCESS. THE CONTRACTOR SHALL WORK WITH THE A/E AND THE

OWNER TO DETERMINE WHICH PORTIONS OF EXISTING SYSTEMS MUST REMAIN ACTIVE

AND WHICH PORTIONS MUST BE DEMOLISHED.

6. CONTRACTOR SHALL FIELD VERIFY ACTUAL LOCATION AND SIZES OF EXISTING CONDUIT,

WIRING, AND EQUIPMENT.

7. IF ASBESTOS OR PCB MATERIAL IS ENCOUNTERED IT WILL BE REMOVED BY THE OWNER.

8. LAMPS CONTAINING MERCURY (FLUORESCENT, METAL HALIDE, SODIUM VAPOR,

MERCURY VAPOR, ETC.) SHALL BE DISPOSED OF IN A PROPER HAZARDOUS WASTE

RECYCLING FACILITY.

9. PATCH AND REPAIR ALL FLOOR, WALL AND CEILING OPENINGS DUE TO DEMOLITION

WHICH ARE NOT TO BE RE-USED TO MATCH EXISTING CONSTRUCTION.

10. CONTRACTOR SHALL PROTECT ALL WALLS, CEILINGS, FLOORS, LIGHTS, AND OTHER

FINISHED SURFACES THAT ARE NOT TO BE REMOVED. IF DAMAGED, CONTRACTOR SHALL

REPAIR TO MATCH EXISTING CONDITIONS AT NO ADDITIONAL COST TO THE OWNER.

11. BACKFILLING SHALL PROMPTLY FOLLOW UNDERGROUND DEMOLITION OR REMOVAL

WORK AND SHALL CONTINUE AS THE DEMOLITION PROGRESSES.

12. EXISTING CONDUIT SYSTEMS MAY BE REUSED FOR THE INSTALLATION OF NEW

CONDUCTORS IF THEY ARE DEEMED TO BE IN GOOD CONDITION AND OF ADEQUATE SIZE

FOR CODE-COMPLIANT INSTALLATION OF THE NEW CONDUCTORS. REWORK/REROUTE

CONDUIT AS NECESSARY TO PROVIDE FEEDS PER POWER AND/OR LIGHTING PLANS.

13. PROVIDE BLANK COVER OVER ANY ABANDONED AND REMAINING ROUGH-INS OR

JUNCTION BOXES TO MATCH EXISTING.

ELECTRICAL DEMOLITION GENERAL NOTES

1. FIELD-VERIFY LOCATIONS AND RATINGS OF VERTICAL AND HORIZONTAL BUILDING

ASSEMBLIES. PROVIDE APPROPRIATE FIRESTOPPING SYSTEMS AT ALL THROUGH-

WALL/FLOOR PENETRATIONS PER SPECIFICATIONS TO MEET ALL APPLICABLE

CODES.

2. BRANCH/FEEDER CONDUITS SHOWN ON DRAWINGS ARE SCHEMATIC ONLY.

CONDUIT RUNS SHALL COMPLY WITH CONDUIT SPECIFICATIONS AND CONTAIN

BENDS THAT ARE NO GREATER THAN 90 DEGREES. CONDUITS ABOVE GRADE

SHALL BE RUN PARALLEL TO OR PERPENDICULAR WITH BUILDING STEEL AND/OR

ARCHITECTURAL LINES.

3. ALL FEEDER AND BRANCH TO PANELS, MOTORS, LIGHTS, RECEPTACLES,

EQUIPMENT, GENERAL DISTRIBUTION, ETC. SHALL CONTAIN AN EQUIPMENT

GROUNDING CONDUCTOR SIZED ACCORDING TO THE N.E.C. THE CONDUIT SYSTEM

SHALL NOT BE CONSIDERED AN ACCEPTABLE GROUND.

ELECTRICAL GENERAL NOTES

VARIABLE FREQUENCY DRIVE WITH INTEGRAL DISCONNECTING MEANS

THREE PHASE MOTOR CONNECTION, 3 HORSE POWER

SINGLE PHASE MOTOR CONNECTION, 1/3 HORSE POWER

SAFETY SWITCH DISCONNECTING MEANS

SAFETY SWITCH DISCONNECTING MEANS, FUSIBLE

COMBINATION MOTOR STARTER AND FUSIBLE DISCONNECTING MEANS

DIRECT ELECTRICAL CONNECTION

DUPLEX RECEPTACLE MOUNTED VERTICALLY AT 16" AFF. TO THE

BOTTOM OF THE DEVICE BOX (TYPICAL UNLESS OTHERWISE NOTED)

QUADRUPLEX RECEPTACLE MOUNTED VERTICALLY AT 16" AFF. TO THE

BOTTOM OF THE DEVICE BOX (TYPICAL UNLESS OTHERWISE NOTED)

DUPLEX GROUND FAULT CIRCUIT INTERRUPTER RECEPTACLE

MOUNTED VERTICALLY AT 16" AFF. TO THE BOTTOM OF THE DEVICE

BOX (TYPICAL UNLESS OTHERWISE NOTED)

MULTI-PHASE RECEPTACLE, SEE PLAN FOR TYPE

PANELBOARD

1/3

GFCI

ELECTRICAL SYMBOL LEGEND

COMMUNICATIONS DEVICE ROUGH-IN

UNIT A

UNIT C

UNIT B

UNIT D

UNIT E

PROJECT NO.

DRAWN

REVIEWED

GMB

No part of this drawing may be used or reproduced in any form or by any means, or stored in a database or retrieval system, without prior written permission of

Copyright 2017 All Rights Reservedc

ARCHITECTURE + ENGINEERING

85 East Eighth Street, Suite 200

P. 616.796.0200 F. 616.796.0201

HOLLAND LAB

www.gmb.com

N O R

TH

KEYPLAN

Holland, Michigan 49423

2025 East Beltline SE, Suite 308

GRAND RAPIDS LAB

Grand Rapids, Michigan 49546

310 North Alabama Street, Suite 230

INDIANAPOLIS LAB

Indianapolis, IN 46204

C L o c a l P ro je c ts \5 -4 E C E N T R A L m a tt k .r v t

/1 /2 :1 :1 A M

2E1.1A

5-4013

BID PACK 2 - UNIT 'A'

ELECTRICAL PLANS

MCK

B

ID

P A C K H E R B

IS

O N W O O D S S C H O O L

D E W

IT

T P U B L

IC

S C H O O L S

D E W

IT

T M

IC

H

IG

A N

N O R

TH

1/8" = 1'-0"

PARTIAL UNIT 'A' ELECTRICAL PLANN

O R

TH

1/8" = 1'-0"

PARTIAL UNIT 'A' DEMOLITION ELECTRICAL PLAN

NOTES: EX. WESTINGHOUSE TYPE "NQP"; FIELD-VERIFY THAT EX. 3-POLE 20A CIRCUIT BREAKER IN SPACES 25/27/29 IS INDEED SPARE BEFORE SELECTING OPTION #2

TOTAL CONNECTED CURRENT: 10 A

TOTAL CONNECTED LOAD: 3.6 kVA

PHASE LOAD: 1,201 VA 1,201 VA 1,201 VA

H-29 1,201 0 H-30

H-27 1,201 0 H-28

H-25

POWER-OP. BLEACHERS A141 (OPTION #2

ONLY)

20 A 3

1,201 0

3 30 A EX. HVAC UNIT

H-26

H-23 EX. SPARE 20 A 1 0 0 1 20 A EX. SPARE H-24

H-21 EX. LOAD 20 A 1 0 0 1 20 A EX. LOAD H-22

H-19 EX. LOAD 20 A 1 0 0 1 20 A EX. LOAD H-20

H-17 EX. LOAD 20 A 1 0 0 1 20 A EX. LOAD H-18

H-15 EX. LOAD 20 A 1 0 0 1 20 A EX. LOAD H-16

H-13 EX. LOAD 20 A 1 0 0 1 20 A EX. LOAD H-14

H-11 EX. LOAD 20 A 1 0 0 1 20 A EX. LOAD H-12

H-9 EX. LOAD 20 A 1 0 0 1 20 A EX. LOAD H-10

H-7 EX. LOAD 20 A 1 0 0 1 20 A EX. LOAD H-8

H-5 EX. LOAD 20 A 1 0 0 1 20 A EX. LOAD H-6

H-3 EX. LOAD 20 A 1 0 0 1 20 A EX. LOAD H-4

H-1 EX. LOAD 20 A 1 0 0 1 20 A EX. LOAD H-2

CIRCUIT CIRCUIT DESCRIPTION TRIP POLES A B C POLES TRIP CIRCUIT DESCRIPTION CIRCUIT

PROVIDE WITH THE FOLLOWING:

ENCLOSURE: TYPE 1 SUPPLY FROM: EX. PANEL 'MDP2'

MOUNTING: FLUSH SCCR: 10KA MAINS RATING: 225 A

LOCATION: EX. GYMNASIUM A141 DISTRIBUTION SYSTEM: 208Y/120V 3PH 4W MAINS TYPE: MAIN LUG

PANELBOARD: EX. PANEL 'H'

NOTES: EX. WESTINGHOUSE TYPE "NQP"

TOTAL CONNECTED CURRENT: 10 A

TOTAL CONNECTED LOAD: 3.6 kVA

PHASE LOAD: 1,201 VA 1,201 VA 1,201 VA

K-41 0 1,201 K-42

K-39 0 1,201 K-40

K-37

EX. HVAC UNIT 20 A 3

0 1,201

3 20 A

POWER-OP. BLEACHERS A141 (OPTION #1

ONLY)

K-38

K-35 0 0 K-36

K-33

EX. SPARE 20 A 2

0 0 K-34

K-31 EX. LOAD 20 A 1 0 0

3 20 A EX. HVAC UNIT

K-32

K-29 EX. LOAD 20 A 1 0 0 1 20 A EX. LOAD K-30

K-27 EX. LOAD 20 A 1 0 0 1 20 A EX. LOAD K-28

K-25 EX. LOAD 20 A 1 0 0 1 20 A EX. LOAD K-26

K-23 EX. LOAD 20 A 1 0 0 1 20 A EX. LOAD K-24

K-21 EX. LOAD 20 A 1 0 0 1 20 A EX. LOAD K-22

K-19 EX. LOAD 20 A 1 0 0 1 20 A EX. LOAD K-20

K-17 EX. LOAD 20 A 1 0 0 1 20 A EX. LOAD K-18

K-15 EX. LOAD 20 A 1 0 0 1 20 A EX. LOAD K-16

K-13 EX. LOAD 20 A 1 0 0 1 20 A EX. LOAD K-14

K-11 EX. LOAD 20 A 1 0 0 1 20 A EX. LOAD K-12

K-9 EX. LOAD 20 A 1 0 0 1 20 A EX. LOAD K-10

K-7 EX. LOAD 20 A 1 0 0 1 20 A EX. LOAD K-8

K-5 EX. LOAD 20 A 1 0 0 1 20 A EX. LOAD K-6

K-3 EX. LOAD 20 A 1 0 0 1 20 A EX. LOAD K-4

K-1 EX. LOAD 20 A 1 0 0 1 20 A EX. LOAD K-2

CIRCUIT CIRCUIT DESCRIPTION TRIP POLES A B C POLES TRIP CIRCUIT DESCRIPTION CIRCUIT

PROVIDE WITH THE FOLLOWING: NEW 3-POLE 20A CIRCUIT BREAKER ONLY IF ELECTING TO CHOOSE OPTION #1 (CIRCUITING BLEACHERS TO THIS PANEL)

ENCLOSURE: TYPE 1 SUPPLY FROM: EX. PANEL 'MDP2'

MOUNTING: FLUSH SCCR: 10KA MAINS RATING: 225 A

LOCATION: EX. PASSAGE A135 DISTRIBUTION SYSTEM: 208Y/120V 3PH 4W MAINS TYPE: MAIN LUG

PANELBOARD: EX. PANEL 'K'

ELECTRICAL KEYNOTES

D01 DEMO EX. DUAL-CHANNEL POWER & COMMUNICATIONS

SURFACE RACEWAY AND ALL DEVICES THEREIN. REMOVE

TWO CATEGORY 5(E) UTP OR EQUIV. HORIZONTAL

DATA/VOICE COMMUNICATIONS CABLES AT EACH RACEWAY

LOCATION BACK TO COMMUNICATIONS DISTRIBUTION

EQUIPMENT IN STORAGE C108 ACROSS THE CORRIDOR

NORTH OF THE LOCKER AREA. REMOVE ONE RG-6/U COAXIAL

VIDEO COMMUNICATIONS CABLE AT EACH RACEWAY

LOCATION BACK TO NEAREST TAP OR SPLITTER ON CATV

DISTRIBUTION SYSTEM. REMOVE ANY ABANDONED CONDUITS

OR RACEWAYS THAT CONTAIN CABLES, MAINTAINING ANY

EXISTING COMM. CABLES AND/OR COMMON RACEWAYS THAT

SERVE OTHER COMM. OUTLETS TO REMAIN.

D02 DEMO EX. 3/4" POWER AND 3/4" OR 1" COMM. CONDUITS ON

WALLS/CEILINGS IN OFFICES AND ON WALLS BEHIND EX.

BLEACHERS THAT SERVE POWER/COMM. OUTLETS THAT ARE

TO BE DEMO'D. REMOVAL OF THE CONDUITS ARE NECESSARY

TO PERMIT NEW BLEACHER INSTALLATION.

D03 EX. 3/4" POWER AND 1" COMM. CONDUITS ON CEILING OF

LOCKER AREA TO REMAIN, ALONG WITH ANY POWER BRANCH

CIRCUIT WIRING AND COMM. CABLES THAT SERVE OUTLETS

ON SURFACE RACEWAY IN OFFICE A119.

D04 EX. POWER CONDUITS AND COMM. CABLES ABOVE CEILING

OF LOCKER AREA TO REMAIN, ALONG WITH ANY POWER

BRANCH CIRCUIT WIRING AND COMM. CABLES THAT SERVE

OUTLETS ON SURFACE RACEWAY IN OFFICE A119. CEILING

SPACE IS ACCESSIBLE THROUGH ACCESS DOORS IN WEST

WALL OF GYM MEZZANINE ABOVE.

D05 DISCONNECT AND REMOVE POWER BRANCH CIRCUIT

CONDUIT AND ASSOCIATED SURFACE-MOUNTED RECEPTACLE

ROUTED BEHIND BLEACHERS TO PERMIT NEW BLEACHER

INSTALLATION. RETAIN EX. BRANCH CIRCUIT (ASSUMED TO

ORIGINATE AT RECEPTACLE ON OPPOSITE SIDE OF WALL IN

OFFICE A137) FOR CONNECTION TO NEW RECEPTACLE AS

SHOWN ON ELECTRICAL PLAN.

D06 REFER TO OPTIONS FOR BRANCH CIRCUIT CONNECTION OF

NEW BLEACHERS AS SHOWN ON ELECTRICAL PLAN. IF

OPTION #1 IS SELECTED, DISCONNECT EX. LAUNDRY EQUIP.

BRANCH CIRCUIT WIRING IN EX. PANEL 'K' AND CAP OFF

WIRING IN PANEL, REMOVE ASSOCIATED 3-POLE 30A CIRCUIT

BREAKER AND RETURN TO OWNER. THIS WILL MAKE A 3-POLE

SPACE AVAILABLE FOR NEW BLEACHER EQUIP.

E01 AT CONTRACTOR OPTION, CONNECT NEW BLEACHER SYSTEM

EQUIP. TO NEW 208V 3PH 20A BRANCH CIRCUIT FROM EITHER

PANEL 'K' OR PANEL 'H'. CONTRACTOR SHALL FIELD-VERIFY

ALL RELEVANT EXISTING CONDITIONS AS REQ'D TO SELECT

THE BEST OPTION. BOTH OPTIONS ARE SHOWN IN TERMS OF

SUGGESTED CONDUIT ROUTE ON PLANS AND RELATED

BRANCH CIRCUIT CONNECTIONS ON RESPECTIVE

PANELBOARD SCHEDULES.

E02 CONTRACTOR OPTION #1: SUGGESTED CONDUIT ROUTING

FOR OPTION TO CONNECT NEW BLEACHER SYSTEM EQUIP. TO

PANEL 'K'. CONDUIT ACROSS LOCKER ROOM MAY BE

EXPOSED ON WALLS/CEILING IN A NEAT MANNER SIMILAR TO

OTHER EX. CONDUITS. FIELD-VERIFY EXISTING CONDITIONS

AND OBSTRUCTIONS FOR EXACT ROUTING.

E03 CONTRACTOR OPTION #1: SUGGESTED CONDUIT ROUTING

FOR OPTION TO CONNECT NEW BLEACHER SYSTEM EQUIP. TO

PANEL 'K'. CONDUIT SHALL BE ROUTED IN CEILING SPACE

ABOVE LOCKER ROOM CEILING WHERE POSSIBLE.

FIELD-VERIFY EXISTING CONDITIONS AND OBSTRUCTIONS

FOR EXACT ROUTING. CEILING SPACE IS ACCESSIBLE

THROUGH ACCESS DOORS IN WEST WALL OF GYM MEZZANINE

ABOVE.

E04 CONTRACTOR OPTION #2: SUGGESTED CONDUIT ROUTING

FOR OPTION TO CONNECT NEW BLEACHER SYSTEM EQUIP. TO

PANEL 'H'. CONDUIT ACROSS LOCKER ROOM MAY BE

EXPOSED ON WALLS/CEILING IN A NEAT MANNER SIMILAR TO

OTHER EX. CONDUITS. FIELD-VERIFY EXISTING CONDITIONS

AND OBSTRUCTIONS FOR EXACT ROUTING.

E05 CONTRACTOR OPTION #2: SUGGESTED CONDUIT ROUTING

FOR OPTION TO CONNECT NEW BLEACHER SYSTEM EQUIP. TO

PANEL 'H'. CONDUIT SHALL BE ROUTED IN CEILING SPACE

ABOVE LOCKER ROOM CEILING WHERE POSSIBLE AND ABOVE

SUSPENDED CEILING IN CORRIDOR. FIELD-VERIFY EXISTING

CONDITIONS AND OBSTRUCTIONS FOR EXACT ROUTING.

CEILING SPACE IS ACCESSIBLE THROUGH ACCESS DOORS IN

WEST WALL OF GYM MEZZANINE ABOVE.

E06 CONTRACTOR OPTION #2: ROUTE CONDUIT ACROSS WALL

BEHIND BLEACHER SYSTEM ONCE NEW WALL BRACING HAS

BEEN INSTALLED.

E07 PROVIDE NEW SURFACE-MOUNTED RECEPTACLE AND

RECONNECT TO EXISTING BRANCH CIRCUIT WIRING ONCE

NEW BLEACHER SYSTEM WALL BRACING HAS BEEN

INSTALLED.

08.14.2017 BID PACK 2

5-4013 G0-02
5-4013 2A2-1A
5-4013 2E1.1A

File details come from the government source that posted it. Updated .