Data_Centers_Expansion_-_HVAC_and_UPS_Part_List.xlsx

XLSX spreadsheet 12 KB Posted

Attached to
Data Centers HVAC and UPS State and local contract opportunity
Solicitation number
2024-IFB-117
Issued by
New Haven County, Connecticut

About this file

The document is a parts list for a data center expansion project for the City of New Haven, Connecticut, involving the procurement of HVAC and Uninterruptible Power Supply (UPS) equipment for two locations: NHPD HQ and Wintergreen. The project involves purchasing specific Vertiv equipment, including two 35kW CRV systems with air-cooled sensors and condensers, two UPS systems with capacities ranging from 40kW to 60kW, and multiple power distribution units (PDUs) with various configurations. The bid specification explicitly states that no substitute items will be accepted, indicating a precise equipment requirements approach.

The equipment list details specific part numbers for each component, with quantities ranging from one to two units per location. The PDUs include monitored and switched units with varying voltage, amperage, and connector configurations, suggesting a comprehensive approach to power management and redundancy. The total project appears to be focused on enhancing data center infrastructure with high-reliability power and cooling systems, using specialized Vertiv equipment to meet the City of New Haven's specific technical requirements. No specific pricing, funding sources, or contract term details are provided in the available documentation.

View the file

Other files for this state and local contract opportunity

Other files attached to Data Centers HVAC and UPS, newest first.
File Type Posted
Data_Centers_HVAC_and_UPS.pdf PDF
Vertiv_UPS_and_CRV_Units_for_Data_Center_Expansions.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

QtyDescPart#Location
2Two Vertiv 35kw CRV systems with air cooled sensors (CRV SYSTEM)24721532NHPD HQ
1Vertiv UPS EXM SYSTEM (40kW Capacity – 20kW+1 Redundant when load is less than 20kW)24715416NHPD HQ
2Two (2) 35kW Vertiv CRV systems with air cooled condensers (CRV SYSTEM)24724025Wintergreen
1Vertiv UPS (40kW Capacity - Field Scalable to 60kW Capacity) - EXM System EXM System24721883Wintergreen
1RPDU, MONITORED UNIT LEVEL EC, 30A, 120/208V, 5.7KW, VERTICAL, (20) IEC C13, (4)24539454Wintergreen
1RPDU, SWITCHED UNIT LEVEL MONITORING EC, 30A, 120/208V, 5.7KW,
VERTICAL, (24) CO24539505Wintergreen
1RPDU, MONITORED UNIT LEVEL EC, 30A, 208V, 4.9KW, VERTICAL, (36)
COMBINATION C13/24539457Wintergreen
1Geist Switched Unit Level Monitoring MNS5MGB1-24CF18-3TL6A0A10-S

Power distribution unit (rack-mountable) - AC 208 V - 4.9 kW - RS-232, USB, Ethernet 10/100/1000 - input: NEMA L6-30P - output connectors: 24 (IEC 60320 C13/C19) - 0U - 10 ft cord - black powder coat - TAA Compliant 24539498 Wintergreen