DALTON_WALK_In_FREEZER_Specifications_Attachment_B.docx
DOCX document 28 KB Posted
- Attached to
- Walk In "knock-down" style Frost Free Freezer
- Solicitation number
- 2026-RFB-0061
- Issued by
- Sacramento County, San Francisco City, California
About this file
This is a specifications attachment document for Sacramento County Sheriff's Property Warehouse, detailing performance requirements for a walk-in frost-free freezer unit to be procured through Request for Bids (RFB) 2026 RFB 0061. The procurement involves the purchase, delivery, and assembly of a new, prefabricated, unused freezer kit compatible with the existing unit. The freezer specifications emphasize the Dalton brand walk-in system, which features a foamed-in-place angle iron frame with welded hinge tapping plates and handle strike mounting plates on both door and jamb components, reinforced with 3/16-inch steel plates and a full 4-inch thermal break of high-impact PVC. Additional specifications include three vertical cam locks on each vertical seam of wall panels, lock strikes positioned on one-foot centers around floors and ceilings for flexible door jamb placement, full-thickness 3/8-inch NSF radius floors maintaining full 4-inch polyurethane insulation, and standardized lock locations at 6¾ inches from panel edges for uniform sealing.
The solicitation is subject to federal requirements under 2 CFR Part 200 and California state procurement standards, with award to be made to the lowest responsive and responsible bidder. The procurement encourages participation from small businesses, SBA-certified small and disadvantaged businesses, women-owned firms, and veteran-owned businesses, though such classifications will not be used as evaluation preferences. Bidders must comply with federal and state certifications including debarment and suspension requirements and Disabled Veteran Business Enterprise (DVBE) participation requirements. Bidders must submit a DVBE Compliance Statement; however, since subcontracting is not anticipated for this equipment purchase, bidders may indicate no subcontracting will be used. DVBE compliance is required for grant eligibility but does not affect bid scoring or pricing evaluation. The procurement is funded by federal and/or state grant funds.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
2026 RFB 0061 Attachment B
DALTON WALK-INS
FEATURE COMPARISON
DOOR AND JAMB: THE DALTON DOOR JAMB HAS FOAMED IN PLACE AN ANGLE IRON FRAME WITH HINGE TAPPING PLATES, CLOSER STRIKE MOUNTING AND HANDLE STRIKE MOUNTING PLATE WELDED TO THE ANGLE FRAME. THE DOOR HAS FOAMED IN PLACE 3/16-INCH-THICK STEEL PLATES TO SERVE AS TAPPING PLATES FOR THE HINGES; THESE PLATES ARE ALSO WELDED TO A SECTION OF ANGLE IRON WHICH RUNS THE FULL LENGTH OF THE DOOR TO ELIMINATE THE POSSIBILITY OF HINGE FAILURE. BOTH DOOR AND JAMB THEN ARE FOAMED WITH A FULL PERIMETER OF HIGH IMPACT PVC WHICH PROVIDES A FULL 4 INCH THERMAL BREAK. NO OTHER WALK-IN MANUFACTURER PROVIDES THE COMBINED STRENGTH AND THERMAL EFFICIENCY OF A DALTON DOOR AND JAMB.
THREE VERTICAL LOCKS: EVERY WALL PANEL HAS AT LEAST THREE CAM LOCKS ON EACH VERTICAL SEAM FOR STRENGTH AND SEAL. OTHER MANUFACTURERS PROVIDE ONLY TWO LOCK ON THE STANDARD 7 FOOT PANEL.
LOCK STRIKES ON l FOOT CENTERS: ALL EDGE FLOOR AND CEILING PANELS ARE MANUFACTURED WITH A LOCK STRID ON ONE FOOT CENTERS COMPLETELY AROUND THE FLOORS AND CEILING TO ALLOW LOCATION OF THI DOOR JAMB WITH-IN ANY ONE FOOT INCREMENT. THE ADDED STRIKES ALSO ALLOW THE USE OF TWO LOCKS IN THE END OF ALL 2 FOOT AND 3 FOOT WALL PANELS AS WELL AS IN EACH LEG OF ONE-BY-ONE CORNERS.
FULL THICKNESS FLOORS: THE 3/8 INCH NSF RADIUS IS PROVIDED IN THE FLOOR PANEL WITHOUT SACRIFICING INSULATION, THE CENTER OF THE PANEL STILL PROVIDES FULL 4 INCH OF POLYURETHANE, OTHER MANUFACTURERS PROVIDE ONLY 3 6/5 INCH INSULATION IN FLOOR PANELS.
LOCK LOCATION: EVERY WALL PANEL, TEE PANEL, AND CORNER PANEL IS MANUFACTURED WITH END LOCKS AT 6 3/4 INCHES OFF EACH EDGE FOR UNIFORMITY OF SEAL. OTHER MANUFACTURERS USE AN OFFSET PATTERN WITH ONLY ONE LOCK IN PANELS LESS THAN 46 INCHES WIDE.