D.6 ATTACHMENT 3 PRICING SPREADSHEET.xlsx
XLSX spreadsheet 68 KB Posted
- Attached to
- F108--VISN 1 Hazardous Waste Disposal Services
- Solicitation number
- 36C24123Q0025
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24123Q0025 0005.docx | DOCX document | |
| 36C24123Q0025 0004.docx | DOCX document | |
| Revised E.7 Addendum to _52.212-2.docx | DOCX document | |
| Revised D.6 ATTACHMENT 3 PRICING SPREADSHEET.xlsx | XLSX spreadsheet | |
| 36C24123Q0025 0003.docx | DOCX document | |
| Revised Performance Work Statement.docx | DOCX document | |
| 36C24123Q0025 0002.docx | DOCX document | |
| 36C24123Q0025 0001.docx | DOCX document | |
| D.5 ATTACHMENT 2 SATELLITE AND MAIN ACCUMULATION AREAS.docx | DOCX document | |
| D.4 ATTACHMENT 1 GENERATORS - SCHEDULE - POCs.docx | DOCX document | |
| D.1 PERFORMANCE REQUIREMENTS.pdf | ||
| 36C24123Q0025.docx | DOCX document | |
| P07 WL 1996-0223 Rev 58 dated 12-27-2022.pdf |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Table 1 Solicitation Attachment E - Price Schedule (Tiered Pricing) VISN 1 Total Quantities of Wastes Estimated to be Disposed Annually (All facilities)
| *Cost of drum, packing material, liner, labeling must be included in all Lab Pack disposal pricing. E-manifest fees must be included in the cost of each line item. Level D PPE must in be included in all labor rates. | 1st Period of BPA: Defined/Aligned with GSA Contract, (Oct 22, | ||||
| 2022- Oct 21, 2023) | 2nd Period of BPA: Defined/Aligned with GSA Contract, (Oct 22, | ||||
| 2023-Oct 21, 2024) | 3rd Period of BPA: Defined/Aligned with GSA Contract, (Oct 22, | ||||
| 2024-Oct 21, 2025) | 4th Period of BPA: Defined/Aligned with GSA Contract, (Oct 22, | ||||
| 2025-Oct 21, 2026) | 5th Period of BPA: Defined/Aligned with GSA Contract, (Oct 22, 2026-Oct 21, |
2027)
| Item # | Waste Stream Description | Method of Disposal | Estimated Quantity | UOM | Container Size | Base Year | 2nd Period of BPA Price Per Unit | 3rd Period of BPA Price Per Unit | 4th Period of BPA Price Per Unit | 5th Period of BPA Price Per Unit |
| 1 | Hazardous/Non Hazardous Lab Pack | Incineration no repack | 15 | EACH | 55 gal | |||||
| 2 | Hazardous/Non Hazardous Lab Pack | Incineration no repack | 20 | EACH | 30 gal | |||||
| 3 | Hazardous/Non Hazardous Lab Pack | Incineration no repack | 60 | EACH | 20 gal | |||||
| 4 | Hazardous/Non Hazardous Lab Pack | Incineration no repack | 210 | EACH | 05 gal | |||||
| 5 | Hazardous/Non Hazardous Loosepack | Incineration no repack | 115 | EACH | 55 gal | |||||
| 6 | Hazardous/Non Hazardous Loosepack | Incineration no repack | 20 | EACH | 30 gal | |||||
| 7 | Hazardous/Non Hazardous Loosepack | Incineration no repack | 15 | EACH | 20 gal | |||||
| 8 | Hazardous/Non Hazardous Loosepack | Incineration no repack | 10 | EACH | 16 gal | |||||
| 9 | Hazardous/Non Hazardous Loosepack | Incineration no repack | 5 | EACH | 5 gal | |||||
| 10 | Mercury Compounds/Mercury Debris/Mercury Containing Devices | Retort/Recycling | 1 | EACH | 55 gal | |||||
| 11 | Mercury Compounds/Mercury Debris/Mercury Containing Devices | Retort/Recycling | 1 | EACH | 40 gal | |||||
| 12 | Mercury Compounds/Mercury Debris/Mercury Containing Devices | Retort/Recycling | 2 | EACH | 30 gal | |||||
| 13 | Mercury Compounds/Mercury Debris/Mercury Containing Devices | Retort/Recycling | 1 | EACH | 20 gal | |||||
| 14 | Mercury Compounds/Mercury Debris/Mercury Containing Devices | Retort/Recycling | 10 | EACH | 05 gal | |||||
| 15 | Mercury Compounds | Incineration | 1 | EACH | 05 gal | |||||
| 16 | Dental Amalgam Filters for Recycling | Recycling | 3 | EACH | 20 gal (5 gals |
overpacked)
| 18 | Aerosols (CFC and non CFC) | Incineration | 10 | EACH | 55 gal | |||||||
| 19 | Aerosols (CFC and non CFC) | Incineration | 5 | EACH | 30 gal | |||||||
| 20 | Aerosols (CFC and non CFC) | Incineration | 10 | EACH | 20 gal | |||||||
| 21 | Aerosols (CFC and non CFC) | Incineration | 2 | EACH | 18 gal | |||||||
| 22 | Aerosols (CFC and non CFC) | Incineration | 2 | EACH | 16 gal | |||||||
| 23 | Aerosols (CFC and non CFC) | Incineration | 5 | EACH | 12 gal | |||||||
| 24 | Aerosols (CFC and non CFC) | Incineration | 30 | EACH | 05 gal | |||||||
| 25 | Flammable Liquids >10,000 BTU | Incineration | 4 | EACH | 55 gal | |||||||
| 26 | Flammable Liquids >10,000 BTU | Incineration | 1 | EACH | 30 gal | |||||||
| 27 | Flammable Liquids 5,000-10,000 BTU | Incineration | 15 | EACH | 55 gal | |||||||
| 28 | Flammable Liquids 5,000-10,000 BTU | Incineration | 10 | EACH | 30 gal | |||||||
| 29 | Flammable Liquids >10,000 BTU | Fuels Blending | 1 | EACH | 55 gal | |||||||
| 30 | Flammable Liquids >10,000 BTU | Fuels Blending | 1 | EACH | 30 gal | |||||||
| 31 | Flammable Liquids 5,000-10,000 BTU | Fuels Blending | 30 | EACH | 55 gal | |||||||
| 32 | Flammable Liquids 5,000-10,000 BTU | Fuels Blending | 20 | EACH | 30 gal | |||||||
| 33 | Flammable Liquids >10,000 BTU | Recycling | 1 | EACH | 55 gal | |||||||
| 34 | Flammable Liquids >10,000 BTU | Recycling | 1 | EACH | 30 gal | |||||||
| 35 | Flammable Liquids 5,000-10,000 BTU | Recycling | 1 | EACH | 55 gal | |||||||
| 36 | Flammable Liquids 5,000-10,000 BTU | Recycling | 1 | EACH | 30 gal | |||||||
| 37 | Waste Oil, <1% Halogens, >1% Water | Incineration | 5 | EACH | 55 gal | |||||||
| 38 | Oil or Diesel Fuel or Gasoline Contaminated Debris | Incineration | 10 | EACH | 55 gal | |||||||
| 39 | Oil or Diesel Fuel or Gasoline Contaminated Debris | Incineration | 10 | EACH | 5 gal | |||||||
| 40 | Oil or Diesel Fuel or Gasoline Contaminated Debris | Incineration | 5 | EACH | 30 gal | |||||||
| 41 | Oil or Diesel Fuel or Gasoline Contaminated Debris | Recycling | 1 | EACH | 55 gal | |||||||
| 42 | Oil or Diesel Fuel or Gasoline Contaminated Debris | Recycling | 1 | EACH | 30 gal | |||||||
| 43 | Oil or Diesel Fuel or Gasoline | Incineration | 20 | EACH | 55 gal | |||||||
| 44 | Oil or Diesel Fuel or Gasoline | Incineration | 15 | EACH | 30 gal | |||||||
| 45 | Oil or Diesel Fuel or Gasoline | Incineration | 2 | EACH | 16 gal | |||||||
| 46 | Oil or Diesel Fuel or Gasoline | Incineration | 10 | EACH | 5 gal | |||||||
| 47 | Oil or Diesel Fuel or Gasoline | Fuels Blending | 1 | EACH | 55 gal | |||||||
| 48 | Oil or Diesel Fuel or Gasoline | Fuels Blending | 1 | EACH | 30 gal | |||||||
| 49 | Oil or Diesel Fuel or Gasoline | Recycling | 2 | EACH | 55 gal | |||||||
| 50 | Oil or Diesel Fuel or Gasoline | Recycling | 1 | EACH | 30 gal | |||||||
| 51 | PCB Oil <50 ppm | Incineration | 1 | EACH | 55 gal | |||||||
| 52 | PCB Oil 50 - 500 ppm | Incineration | 1 | EACH | 55 gal | |||||||
| 53 | PCB Oil >500 ppm | Incineration | 1 | EACH | 55 gal | |||||||
| 54 | Nonhazardous liquid | Waste to Energy | 180 | EACH | 55 gal | |||||||
| 55 | Nonhazardous liquid | Waste to Energy | 25 | EACH | 30 gal | |||||||
| 56 | Nonhazardous liquid | Waste to Energy | 40 | EACH | 16 gal | |||||||
| 57 | Nonhazardous liquid | Wastewater treat | 1 | EACH | 55 gal | |||||||
| 58 | Nonhazardous liquid | Stabilization/Landfill | 5 | EACH | 55 gal | |||||||
| 59 | Nonhazardous liquid | Stabilization/Landfill | 1 | EACH | 30 gal | |||||||
| 60 | Corrosive Liquids | Stabilization/Landfill | 15 | EACH | 55 Gal | |||||||
| 61 | Corrosive Liquids | Stabilization/Landfill | 5 | EACH | 30 Gal | |||||||
| 62 | Corrosive Liquids | Stabilization/Landfill | 1 | EACH | 16 Gal | |||||||
| 63 | Nonhazardous solid | Landfill | 1 | EACH | 30 gal | |||||||
| 64 | Nonhazardous solid | Incineration | 5 | EACH | 55 gal | |||||||
| 65 | Nonhazardous solid | Incineration | 1 | EACH | 5 gal | |||||||
| 66 | Nonhazardous solid | Waste to Energy/Incineration | 4 | EACH | 55 gal | |||||||
| 67 | Nonhazardous solid | Waste to Energy/Incineration | 40 | EACH | 30 gal | |||||||
| 68 | Nonhazardous solid | Waste to Energy/Incineration | 2 | EACH | 18 gal | |||||||
| 69 | Nonhazardous solid | Waste to Energy/Incineration | 2 | EACH | 5 gal | |||||||
| 70 | Nonhazardous solid | Landfill | 1 | EACH | 55 gal | |||||||
| 71 | Nonhazardous solid | Landfill | 1 | EACH | 20 gal | |||||||
| 72 | Nonhazardous solid (non-regulated loosepack) | Incineration | 4 | EACH | 55 gal | |||||||
| 73 | Tissue Specimens in formalin Loosepack | Tissue - incineration, Formalin - wastewater | ||||||||||
| treatment | 30 | EACH | 55 gal | |||||||||
| 74 | Lead Acid Batteries | Recycling | 4,250 | LB | pounds | |||||||
| 75 | Alkaline Batteries | Recycling | 6000 | LB | pounds | |||||||
| 76 | NiCad Batteries | Recycling | 1500 | LB | pounds | |||||||
| 77 | Lithium Batteries | Recycling | 2500 | LB | pounds | |||||||
| 78 | Fluorescent Bulbs | Recycling | 31,000 | Linear Foot | Linear Foot | |||||||
| 79 | Fluorescent Bulbs - Utubes | Recycling | 800 | LB | each | |||||||
| 80 | Fluorescent Bulbs - Circular | Recycling | 500 | LB | each | |||||||
| 81 | Mercury or Sodium Vapor Lamps | Recycling | 100 | LB | each | |||||||
| 82 | Paint - flammable | Incineration | 1 | EACH | 55 gal | |||||||
| 83 | Paint - flammable | Fuels Blending | 1 | EACH | 55 gal | |||||||
| 84 | Latex Paint | Incineration | 1 | EACH | 55 gal | |||||||
| 85 | NonPCB ballasts | Recycling | 2000 | LB | pounds | |||||||
| 86 | PCB ballasts | Recycling | 225 | LB | pounds | |||||||
| 87 | Ethylene or Propylene Glycol | Recycling | 5 | EACH | 55 gal | |||||||
| 88 | Ethylene or Propylene Glycol | Wastewater treat | 1 | EACH | 55 gal | |||||||
| 89 | Corrosive Liquids | Incineration | 20 | EACH | 55 gal | |||||||
| 90 | Corrosive Liquids | Incineration | 20 | EACH | 30 gal | |||||||
| 91 | Hazardous/Non Hazardous Pharmaceuticals | |||||||||||
| (including sharps) | Incineration | 25 | EACH | Pallet | ||||||||
| 92 | Hazardous/Non Hazardous Pharmaceuticals | |||||||||||
| (including sharps) | Incineration | 200 | EACH | 55 gal | ||||||||
| 93 | Hazardous/Non Hazardous Pharmaceuticals | |||||||||||
| (including sharps) | Incineration | 20 | EACH | 30 gal | ||||||||
| 94 | Hazardous/Non Hazardous Pharmaceuticals | |||||||||||
| (including sharps) | Incineration | 1 | EACH | 20 Gal | ||||||||
| 95 | Hazardous/Non Hazardous Pharmaceuticals | |||||||||||
| (including sharps) | Incineration | 65 | EACH | 18 Gal | ||||||||
| 96 | Hazardous/Non Hazardous Pharmaceuticals | |||||||||||
| (including sharps) | Incineration | 1 | EACH | 16 gal | ||||||||
| 97 | Hazardous/Non Hazardous Pharmaceuticals | |||||||||||
| (including sharps) | Incineration | 10 | EACH | 12 gal | ||||||||
| 98 | Hazardous/Non Hazardous Pharmaceuticals | |||||||||||
| (including sharps) | Incineration | 40 | EACH | 5 gal | ||||||||
| 99 | Hazardous/Non Hazardous Pharmaceuticals | |||||||||||
| (including sharps) | Incineration | 10 | EACH | 2 gal | ||||||||
| 100 | Lead for Recycling | Recycling | 180 | LB | per pound | |||||||
| 101 | Nonregulated Scintillation Vials | Fuels Blending | 1 | EACH | 30 gal | |||||||
| 102 | Empty Drums for Recycling | Recycling | 1 | EACH | 55 gal | |||||||
| 103 | Limestone chips and water, non-RCRA from hospital lab wastewater passive acid neutralization tanks | Landfill | 10 | Ton | EACH | |||||||
| 104 | Non-haz water/solids from catch basins or oil water | |||||||||||
| separators | Wastewater treat | 5,000 | GALLONS | per gallon | ||||||||
| 105 | Used medical implant/devices | Incineration | 2 | EACH | 5 gal | |||||||
| 106 | Barium Sulfate Solution (20 gal) | Incineration | 10 | EACH | 55 gal | |||||||
| 107 | Barium Sulfate Solution (20 gal) | Incineration | 5 | EACH | 30 gal | |||||||
| 108 | Barium Sulfate Solution (20 gal) | Incineration | 3 | EACH | 20 gal | |||||||
| 109 | Barium Sulfate Solution (20 gal) | Incineration | 10 | EACH | 18 gal | |||||||
| 110 | Pallet of Latex Paint Cans & Pails for Waste to Energy | Waste to Energy | 1 | EACH | EACH | |||||||
| 111 | Bulk Oily Water ( <3%suspended solids) | Wastewater treat | 1000 | EACH | gallon | |||||||
| 112 | Characteristic Solids (Stabilization) | Stabilization | 5 | EACH | 55 gal | |||||||
| 113 | Characteristic Solids (Stabilization) | Stabilization | 2 | EACH | 30 gal | |||||||
| 114 | Characteristic Solids (Stabilization) | Stabilization | 1 | EACH | 5 gal | |||||||
| 115 | 55 gal Flammable liquid <5000 BTU, Fuel Blending | Fuel Blending | 1 | EACH | 55 gal | |||||||
| 116 | 30 gal Flammable liquid <5000 BTU, Fuel Blending | Fuel Blending | 10 | EACH | 30 gal | |||||||
| 117 | 55 gal Flammable liquid <5000 BTU, Incineration | Incineration | 2 | EACH | 55 gal | |||||||
| 118 | 30 gal Flammable liquid <5000 BTU, Incineration | Incineration | 1 | EACH | 30 gal | |||||||
| 119 | Propane Tank (5 gal grille size) | Reclaim or incineration | 10 | EACH | EACH | |||||||
| 120 | MAP Gas, lecture bottle | Reclaim or incineration | 5 | EACH | EACH | |||||||
| 121 | Compressed Gases, Methane, lecture bottle | Reclaim or incineration | 2 | EACH | EACH | |||||||
| 122 | Flammable Gases, lecture bottle | Reclaim or incineration | 1 | EACH | EACH | |||||||
| 123 | Nonhaz medical calibration cylinders/Blood Gas Analyzer | Reclaim or incineration | 20 | EACH | EACH | |||||||
| 124 | Ethylene Oxide 1-3 inches | Reclaim or incineration | 1 | EACH | cartridge | |||||||
| 125 | Ethylene Oxide 1-3 inches | Reclaim or incineration | 1 | EACH | lecture | |||||||
| 126 | Propane Cylinder (grill style) | Reclaim or incineration | 5 | EACH | EACH | |||||||
| 127 | Helium Cylinder | Reclaim or incineration | 5 | EACH | EACH | |||||||
| 128 | Oxygen Cylinder (medical gas) | Reclaim or incineration | 5 | EACH | EACH | |||||||
| 129 | Nitrous Oxide Cyc linger | Reclaim or incineration | 5 | EACH | EACH | |||||||
| 130 | Dichlorodifluoromethane | Reclaim or incineration | 1 | EACH | EACH | |||||||
| 131 | Hydrogen sulfide 5-50 parts per million | Reclamation | 1 | EACH | cartridge | |||||||
| 132 | Leaking Lead Acid Batteries | Stabilization | 1 | EACH | 55 gal | |||||||
| 133 | Wastewater from catch basin cleanings (no minimum volume) | Recycling | 5625 | GALLONS | gallon | |||||||
| 134 | Solids from catch basin cleanings (no minimum volume) | Stabilization | 175 | TONS | ton | |||||||
| 135 | Characteristic Solids | Incineration | 10 | EACH | 55 gal | |||||||
| 136 | Ammunition (police rounds) | 1 | EACH | 5 gal | ||||||||
| 137 | Lead-Contaminated Debris | 1 | TONS | ton | ||||||||
| 138 | Lead-Contaminated Debris Roll-off Drop Charge | 1 | EACH | each | ||||||||
| 139 | Smoke Detectors | Recycling/Stabilization | 20 | Each | each | |||||||
| MIXED WASTES | ||||||||||||
| 140 | <1% Uranyl Acetate/<% Lead Citrate/99% Water | Treatment | 1 | EACH | 5 gal | |||||||
| 141 | Acetonitrile/Water/Trifluoroacetic | |||||||||||
| Acid/Triethylamine with I-125 | Treatment | 1 | EACH | 5 gal | ||||||||
| 142 | Methyl Alcohol/Water/Triethylamine with I-125 | Treatment | 1 | EACH | 5 gal | |||||||
| 143 | Acetonitrile/Water/Trifluoroacetic Acid with I-125 | Treatment | 1 | EACH | 5 gal |
| ANALYTICAL SAMPLING | ||||||||||
| 145 | ph | 1 | EACH | EACH | ||||||
| 146 | TCLP 8270 | 1 | EACH | EACH | ||||||
| 147 | TCLP 8240 | 1 | EACH | EACH | ||||||
| 148 | Ignitability, 1010 | 1 | EACH | EACH | ||||||
| 149 | Reactivity, 9010/9030 | 1 | EACH | EACH | ||||||
| 150 | TCLP Metals by EPA 1311 | 2 | EACH | EACH | ||||||
| 151 | Analytical- PCB charge | 1 | EACH | EACH | ||||||
| 152 | VOC Analytical | 2 | EACH | EACH | ||||||
| 153 | SVOC Analytical | 1 | EACH | EACH | ||||||
| 154 | TDS Analytical | 1 | EACH | EACH | ||||||
| 155 | TSS Analytical | 1 | EACH | EACH | ||||||
| LABOR CHARGES | ||||||||||
| * All labor rates must include Level D PPE | ||||||||||
| 156 | Chemist (BS) | 3600 | Hour | Annually | ||||||
| 157 | Field Technician | 40 | Hour | Annually | ||||||
| 158 | Driver | 300 | Hour | Annually | ||||||
| 159 | Cusco/Tanker Equipment & Operator | 75 | Hour | Annually | ||||||
| 160 | Certified UST A/B Operator | 250 | Hour | Annually | ||||||
| 161 | Site Foreman | 100 | Hour | Annually | ||||||
| 162 | Sr. Field Technician | 30 | Hour | Annually | ||||||
| SUPPLIES | ||||||||||
| 163 | 55 gal steel closed top | 40 | EACH | EACH | ||||||
| 164 | 55 gal steel open top | 115 | EACH | EACH | ||||||
| 165 | 55 gal poly closed top | 215 | EACH | EACH | ||||||
| 166 | 30 gal poly closed top | 130 | EACH | EACH | ||||||
| 167 | 16 gal poly closed top | 65 | EACH | EACH | ||||||
| 168 | 5 gal poly closed top | 250 | EACH | EACH | ||||||
| 169 | 5 gal poly carboy | 5 | EACH | EACH | ||||||
| 170 | 55 gal poly open top | 200 | EACH | EACH | ||||||
| 171 | 30 gal poly open top | 90 | EACH | EACH | ||||||
| 172 | 5 gal poly open top | 460 | EACH | EACH | ||||||
| 173 | 16 gal pharmaceutical container | 1 | EACH | EACH | ||||||
| 174 | 12 gal pharmaceutical container | 40 | EACH | EACH | ||||||
| 175 | 8 gal pharmaceutical container | 3 | EACH | EACH | ||||||
| 176 | 2 gal pharmaceutical container | 160 | EACH | EACH | ||||||
| 177 | 1.5 gal mailbox style pharmaceutical container | 1 | EACH | EACH | ||||||
| 178 | 4 fool fluorescent bulb drum | 15 | EACH | EACH | ||||||
| 179 | 4 foot fluorescent bulb box | 50 | EACH | EACH | ||||||
| 180 | 8 foot fluorescent bulb box | 3 | EACH | EACH | ||||||
| 181 | Fluorescent U-tube box | 60 | EACH | EACH | ||||||
| 182 | Fluorescent circular box | 1 | EACH | EACH | ||||||
| 183 | 1.7 liter Container for collection/denaturing of | |||||||||
| DEA/Controlled substances | 64 oz. Rx Destroyer all purpose container | 10 | EACH | EACH | ||||||
| 184 | 3 liter container for collection/denaturing DEA | |||||||||
| controlled substances | 1 gal. Rx Destroyer all purpose container | 10 | EACH | EACH | ||||||
| 185 | Wall mounted collection device for DEA/controlled substances for pharmaceutical waste. Cactus Smart Sink or similar. | Wall mount for 64 oz & 1 gal Rx Destroyer | 10 | EACH | EACH | |||||
| 186 | Liquid Replacement Cartridge 10201 for denaturing | |||||||||
| Solid Replacement Cartridge 10301 for denaturing | Liquid or Solid Replacement Cartridge for wall-mounted denaturing units. | 10 | EACH | EACH | ||||||
| 187 | T-Pack | 15 | EACH | EACH | ||||||
| 188 | 1-Gal Mayo Jars | 125 | EACH | jar | ||||||
| 189 | 18 gal Pharmacy Container with hinged lid | 250 | EACH | EACH | ||||||
| 190 | 1.5 quart Pharmacy Container | 5 | EACH | EACH | ||||||
| 191 | 5.4 quart Controlled Substance Container - Counterbalanced Door Insert | 2 | EACH | EACH | ||||||
| 192 | 5.4 quart Controlled Substance Container - Sharps Collector Wall Cabinet | 2 | EACH | EACH | ||||||
| 193 | non-hazardous 2 gal pharmacy waste bins | 5 | EACH | EACH | ||||||
| 194 | Non-hazardous/hazardous 2 gal pharmacy wall bracket | 5 | EACH | EACH | ||||||
| 195 | 85 gal Overpack | 1 | EACH | EACH | ||||||
| 196 | 55 gal Fiber Drum | 40 | EACH | EACH | ||||||
| 197 | 30 gal Fiber Drum | 30 | EACH | EACH | ||||||
| 198 | 20 gal Fiber Drum | 80 | EACH | EACH | ||||||
| 199 | Bitrex | 5 | EACH | gallon | ||||||
| 200 | Narcsorb (25-lb bag) | 1 | EACH | bag | ||||||
| 201 | Level C - PPE (includes latex gloves and organic vapor cartridges) | 90 | EACH | EACH | ||||||
| 202 | Speedy Dry | 2 | EACH | bag | ||||||
| 203 | Spill Pads (universal) | 1 | EACH | bundle | ||||||
| 204 | Decon Supplies | 3 | EACH | EACH | ||||||
| 205 | Cactus Smart Sink Pharma Lock (1-20 Smart Sinks) | 1 | EACH | EACH | ||||||
| 206 | Cactus Smart Sink Pharma Lock (21-40 Smart Sinks) | 1 | EACH | EACH | ||||||
| 207 | Liquid and solid cartridge for Pharma Lock | 1 | EACH | EACH | ||||||
| 208 | 2.5 gal. jug | 1 | EACH | EACH | ||||||
| 209 | 16 gal open poly | 5 | EACH | EACH | ||||||
| 210 | Limestone Chips (Bag) | 100 | EACH | EACH | ||||||
| 211 | Storm Drain Silt Filters | 1 | EACH | EACH | ||||||
| 212 | Plastic Wide Mouth Jars 500mL | 1 | EACH | EACH | ||||||
| 213 | Drum Containment (Covered) | 1 | EACH | EACH | ||||||
| 214 | Chemical Spill Pads | 5 | EACH | Case of 100 | ||||||
| 215 | 55-Gal Drum Vacuum Head | 1 | EACH | EACH | ||||||
| 216 | 55-Gal Drum Vacuum Crush Resistant Vacuum Hose | |||||||||
| (12 ft.) | 1 | EACH | EACH | |||||||
| 217 | Spill Pads Storage Tote | 10 | EACH | EACH | ||||||
| 218 | Wastewater 0.35 Micron Particulate Filter | 1 | EACH | Case of 12 | ||||||
| 219 | Wastewater 43 oz. Replacement Bottles | 1 | EACH | Pkg of 6 | ||||||
| 220 | Lobby Broom & Dust Pan Set | 1 | EACH | EACH | ||||||
| 221 | 10-Gal Haz Mat Bags | 1 | EACH | Pkg of 24 | ||||||
| 222 | Wide Mouth 1-Gal Square Bottle | 1 | EACH | Pkg of 6 | ||||||
| 223 | X- rated exemption cans (paint cans) | 1 | each | EACH | ||||||
| 224 | Zone B Kit | 1 | each | EACH | ||||||
| 225 | 5 gal 1A2 (steel) | 1 | each | EACH | ||||||
| 226 | Dry Ice | 1 | each | EACH | ||||||
| 227 | Loader with Operator (includes Level D PPE) | 1 | Hour | Hour | ||||||
| 228 | Mobilization of Loader/Roll Off | 4 | EACH | EACH | ||||||
| 229 | Demob of Loader/Roll Off | 4 | EACH | EACH | ||||||
| 230 | Confined Space Equipment | 0 | USE | use | ||||||
| 231 | Shop Vac | 0 | EACH | EACH | ||||||
| 232 | Service Vehicle | 65 | Day | Day | ||||||
| 233 | Tow Behind Compressor | 1 | EACH | EACH | ||||||
| 234 | Drum Top Vacuum | 1 | EACH | EACH | ||||||
| 235 | Roll Off Rental Per day | 1 | Day | Day | ||||||
| 236 | Roll off liner & Cover | 1 | EACH | EACH | ||||||
| 237 | Catch Basin Clam Shell Cleaning (no minimum) | 1 | EACH | EACH | ||||||
| 238 | Jerome Mercury Meter (detection limit 0.01) | 1 | EACH | EACH | ||||||
| 239 | Jerome Mercury Meter (detection limit 0.0001) | 1 | EACH | EACH | ||||||
| 240 | Mercury Vacuum | 1 | EACH | EACH | ||||||
| 241 | PID Meter | 1 | EACH | EACH | ||||||
| 242 | Meter - 4 Gas | 1 | EACH | EACH | ||||||
| 243 | Jetting Truck and Operator (4 hour minimum. Jetting | |||||||||
| truck must be used in conjunction with a vacuum truck (two separate units); the vacuum truck will be invoiced separately. | 1 | Hour | Hour | |||||||
| TRAINING | ||||||||||
| 244 | Annual RCRA/DOT Refresher Training - Onsite or Virtual | Up to 50 employees | 3 | EACH | ||||||
| 245 | Initial RCRA Training - Onsite or Virtual | Up to 15 employees | 1 | EACH | ||||||
| 246 | Initial DOT Training - Onsite or Virtual | Up to 15 employees | 2 | EACH | ||||||
| 247 | Bi-ennial Reporting | Per EPA ID Number | 2 | EACH | ||||||
| 248 | 8 Hour HAZWOPER Refresher Training - Onsite | Up to 15 employees | 1 | EACH | ||||||
| MISC. | ||||||||||
| 249 | Transportation (stop charge) | 85 | EACH | |||||||
| OTHER LABOR RATES | ||||||||||
| 250 | Massachusetts Department of Environmental Protection Licensed Site Professional (LSP) | 20 | Hour | |||||||
| 252 | Licensed Industrial Wastewater Operator | 10 | Hour | |||||||
| 252 | Certified Industrial Hygienist | 30 | Hour | |||||||
| 253 | High Hazard Technician | 10 | Hour | |||||||
| 254 | Sr. Environmental Engineer/Professional Engineer | 40 | Hour | |||||||
| 255 | Mid-Level Environmental Engineer/Scientist | 40 | Hour | |||||||
| 256 | Sr. Environmental Consultant | 40 | Hour |
10/01/2021
File details come from the government source that posted it. Updated .